{"id":5604,"date":"2024-09-13T20:38:58","date_gmt":"2024-09-13T12:38:58","guid":{"rendered":"https:\/\/viox.com\/?post_type=product&#038;p=5604"},"modified":"2024-09-13T20:44:24","modified_gmt":"2024-09-13T12:44:24","slug":"viox-vmm3-250-3p-250a-ac400v-690v-moulded-case-circuit-breaker-mccb","status":"publish","type":"product","link":"https:\/\/test.viox.com\/tr\/urun\/viox-vmm3-250-3p-250a-ac400v-690v-moulded-case-circuit-breaker-mccb\/","title":{"rendered":"VIOX VMM3-250 3P 250A AC400V\/690V MCCB"},"content":{"rendered":"<div class=\"product-intro\">\n<h2>VIOX VMM3-250 3P 250A AC400V\/690V Kal\u0131pl\u0131 Kutulu Devre Kesici (MCCB)<\/h2>\n<h2>\u00dcr\u00fcne Genel Bak\u0131\u015f<\/h2>\n<p>VIOX VMM3-250 Kal\u0131pl\u0131 Kutulu Devre Kesici (MCCB), AC 50Hz, 690V'a kadar nominal \u00e7al\u0131\u015fma gerilimi ve 250A'ya kadar nominal \u00e7al\u0131\u015fma ak\u0131m\u0131na sahip g\u00fc\u00e7 da\u011f\u0131t\u0131m \u015febekeleri i\u00e7in tasarlanm\u0131\u015f y\u00fcksek performansl\u0131 bir cihazd\u0131r. A\u015f\u0131r\u0131 y\u00fck, k\u0131sa devre ve di\u011fer ar\u0131zalara kar\u015f\u0131 \u00fcst\u00fcn koruma sa\u011flarken kompakt boyut, y\u00fcksek kesme kapasitesi, k\u0131sa ark s\u00fcresi ve m\u00fckemmel titre\u015fim \u00f6nleme \u00f6zelliklerine sahiptir.<\/p>\n<h2>Temel \u00d6zellikler<\/h2>\n<ul>\n<li><strong>Nominal Ak\u0131m:<\/strong> 400A'e kadar<\/li>\n<li><strong>Direkler:<\/strong> 2P, 3P, 4P konfig\u00fcrasyonlar\u0131nda mevcuttur<\/li>\n<li><strong>Nominal \u00c7al\u0131\u015fma Gerilimi:<\/strong> 400V\/690V AC<\/li>\n<li><strong>Nominal \u0130zolasyon Gerilimi:<\/strong> 800V<\/li>\n<li><strong>K\u0131rma Kapasitesi:<\/strong> Standart (S) ve Y\u00fcksek (H) tipleri mevcuttur<\/li>\n<li><strong>Uyumluluk:<\/strong> IEC60947-2 ve GB\/T14048.2 standartlar\u0131<\/li>\n<\/ul>\n<h2><b>\u00dcr\u00fcn Kategorisi<\/b><\/h2>\n<ul>\n<li>Devre kesicinin kesme kapasitesine g\u00f6re, a\u015fa\u011f\u0131dakilere ayr\u0131l\u0131r: a standart tip (S tipi); b daha y\u00fcksek tip (H tipi);<\/li>\n<li>Devre kesicinin kablolama y\u00f6ntemine g\u00f6re: a. Kart\u0131n \u00f6n\u00fcnde kablolama; b. Kart\u0131n arkas\u0131nda kablolama; c. Ge\u00e7meli tip; d. \u00c7ekmeli tip;<\/li>\n<li>\u00c7al\u0131\u015fma moduna g\u00f6re: a. Kolla do\u011frudan \u00e7al\u0131\u015ft\u0131rma; b. Kolu \u00e7evirerek \u00e7al\u0131\u015ft\u0131rma; c. Elektrikle \u00e7al\u0131\u015ft\u0131rma;<\/li>\n<li>Kutup say\u0131s\u0131na g\u00f6re: iki kutuplu; \u00fc\u00e7 kutuplu; d\u00f6rt kutuplu;<\/li>\n<li>Aksesuarlara g\u00f6re: alarm kontaklar\u0131, yard\u0131mc\u0131 kontaklar, \u015f\u00f6nt b\u0131rakma, d\u00fc\u015f\u00fck gerilim b\u0131rakma;<\/li>\n<\/ul>\n<h2>Teknik \u00d6zellikler<\/h2>\n<p><b>Devre kesici de\u011feri<\/b><\/p>\n<div class=\"table_wrap\">\n<table border=\"0\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"92\" \/>\n<col width=\"109\" \/>\n<col width=\"53\" \/>\n<col width=\"67\" \/>\n<col span=\"3\" width=\"61\" \/>\n<col width=\"75\" \/>\n<col width=\"69\" \/><\/colgroup>\n<tbody>\n<tr>\n<td width=\"92\" height=\"216\">Model<\/td>\n<td width=\"109\">\u00c7er\u00e7eve de\u011ferlendirmesi<br \/>\nnominal ak\u0131m<br \/>\nGiri\u015f (mA)<\/td>\n<td width=\"53\">Derecelendirilmi\u015f<br \/>\ng\u00fcncel<br \/>\nIn(A)<\/td>\n<td width=\"67\">Derecelendirilmi\u015f<br \/>\n\u00e7al\u0131\u015f\u0131yor<br \/>\nGerilim (V)<\/td>\n<td width=\"61\">Derecelendirilmi\u015f<br \/>\n\u0130zolasyon<br \/>\nGerilim (V)<\/td>\n<td width=\"61\">En y\u00fcksek puan<br \/>\nk\u0131sa devre<br \/>\nk\u0131r\u0131lma<br \/>\nkapasite Icu(kA)<\/td>\n<td width=\"61\">Nominal \u00e7al\u0131\u015fma<br \/>\nk\u0131sa devre<br \/>\nk\u0131r\u0131lma<br \/>\nkapasite Ics(kA)<\/td>\n<td width=\"75\">Say\u0131<br \/>\n.<br \/>\nkutuplar<\/td>\n<td width=\"69\">Flashover<br \/>\nmesafe<br \/>\n(mm)<\/td>\n<\/tr>\n<tr>\n<td height=\"18\">VMM3-125S<\/td>\n<td>125<\/td>\n<td rowspan=\"2\" width=\"53\">16,20,25,32,<br \/>\n40,50,60,80,<br \/>\n100,125<\/td>\n<td rowspan=\"2\">400\/415<\/td>\n<td rowspan=\"2\">1000<\/td>\n<td>25<\/td>\n<td>18<\/td>\n<td>3P<\/td>\n<td rowspan=\"2\">\u226450<\/td>\n<\/tr>\n<tr>\n<td height=\"18\">VMM3-125H<\/td>\n<td>125<\/td>\n<td>35<\/td>\n<td>25<\/td>\n<td>3P<\/td>\n<\/tr>\n<tr>\n<td height=\"18\">VMM3-250S<\/td>\n<td>250<\/td>\n<td rowspan=\"2\" width=\"53\">100,125,160,<br \/>\n180,200,225,<br \/>\n250<\/td>\n<td rowspan=\"2\">400\/690<\/td>\n<td>800<\/td>\n<td>35\/10<\/td>\n<td>25\/5<\/td>\n<td rowspan=\"2\">2P,3P,4P<\/td>\n<td rowspan=\"2\">\u226450<\/td>\n<\/tr>\n<tr>\n<td height=\"18\">VMM3-250S<\/td>\n<td>250<\/td>\n<td>600<\/td>\n<td>50<\/td>\n<td>35<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>&nbsp;<\/p>\n<p><b>T\u00fcm kutuplar ayn\u0131 anda enerjilendirildi\u011finde da\u011f\u0131t\u0131m devre kesicisinin a\u015f\u0131r\u0131 ak\u0131m b\u0131rakmas\u0131n\u0131n ters zamanl\u0131 kesme eylemi \u00f6zellikleri<\/b><\/p>\n<div class=\"table_wrap\">\n<table border=\"0\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"235\" \/>\n<col width=\"43\" \/>\n<col width=\"206\" \/>\n<col width=\"395\" \/><\/colgroup>\n<tbody>\n<tr>\n<td width=\"235\" height=\"18\">Ge\u00e7erli ad\u0131 test edin<\/td>\n<td width=\"43\">Ben\/\u0130\u00e7inde<\/td>\n<td width=\"206\">Atanm\u0131\u015f zaman<\/td>\n<td width=\"395\">Ba\u015flang\u0131\u00e7 durumu<\/td>\n<\/tr>\n<tr>\n<td height=\"18\">A\u00e7ma ak\u0131m\u0131 olmad\u0131\u011f\u0131 kabul edildi<\/td>\n<td>1.05<\/td>\n<td>2h(In\uff1e63A),1h(In\u226463A)<\/td>\n<td>So\u011fuk durum<\/td>\n<\/tr>\n<tr>\n<td height=\"18\">Kabul edilen a\u00e7ma ak\u0131m\u0131<\/td>\n<td>1.3<\/td>\n<td>2h(In\uff1e63A),1h(In\u226463A)<\/td>\n<td>Sekans 1 testinden hemen sonra<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>&nbsp;<\/p>\n<p><b>T\u00fcm kutuplara ayn\u0131 anda enerji verildi\u011finde motor korumas\u0131 i\u00e7in devre kesicinin a\u015f\u0131r\u0131 ak\u0131m b\u0131rakmas\u0131n\u0131n ters zamanl\u0131 kesme eylemi \u00f6zellikleri<\/b><\/p>\n<div class=\"table_wrap\">\n<table border=\"0\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"153\" \/>\n<col width=\"143\" \/>\n<col width=\"395\" \/>\n<col width=\"143\" \/><\/colgroup>\n<tbody>\n<tr>\n<td width=\"153\" height=\"18\">Ak\u0131m ayar\u0131<\/td>\n<td width=\"143\">Atanm\u0131\u015f zaman<\/td>\n<td width=\"395\">Ba\u015flang\u0131\u00e7 durumu<\/td>\n<td width=\"143\">A\u00e7\u0131klama<\/td>\n<\/tr>\n<tr>\n<td height=\"18\">1.0In<\/td>\n<td>&gt;2h<\/td>\n<td>So\u011fuk durum<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td height=\"18\">1,2 in\u00e7<\/td>\n<td>\u22642h<\/td>\n<td>Sekans 1 testinden hemen sonra<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" height=\"36\">1,5 in\u00e7<\/td>\n<td>\u22644 dakika<\/td>\n<td>so\u011fuk durum<\/td>\n<td>10 \u2264 In \u2264 250<\/td>\n<\/tr>\n<tr>\n<td>\u22648 dakika<\/td>\n<td>so\u011fuk durum<\/td>\n<td>250 \u2264 In \u2264 630<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" height=\"36\">7.2In<\/td>\n<td>4s\u2264T\u226410s<\/td>\n<td>so\u011fuk durum<\/td>\n<td>10 \u2264 In \u2264 250<\/td>\n<\/tr>\n<tr>\n<td>6s\u2264T\u226420s<\/td>\n<td>so\u011fuk durum<\/td>\n<td>250 \u2264 In \u2264 800<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>Da\u011f\u0131t\u0131m i\u00e7in devre kesicinin anl\u0131k \u00e7al\u0131\u015fma \u00f6zellikleri 10In\u00b120% olarak ayarlan\u0131r ve motor korumas\u0131 i\u00e7in devre kesicinin anl\u0131k \u00e7al\u0131\u015fma \u00f6zellikleri 12In\u00b120% olarak ayarlan\u0131r.<\/p>\n<h2>\u00c7al\u0131\u015fma Ko\u015fullar\u0131<\/h2>\n<ul>\n<li><strong>Y\u00fckseklik:<\/strong> 2000 m'yi a\u015fmayan<\/li>\n<li><strong>Ortam S\u0131cakl\u0131\u011f\u0131:<\/strong> -5\u00b0C ila +40\u00b0C (24 saatlik ortalama +35\u00b0C'yi ge\u00e7memelidir)<\/li>\n<li><strong>Ba\u011f\u0131l Nem:<\/strong> 40\u00b0C'de 50%'yi ge\u00e7memelidir, daha d\u00fc\u015f\u00fck s\u0131cakl\u0131klarda daha y\u00fcksek neme izin verilir<\/li>\n<li><strong>Kirlilik Seviyesi:<\/strong> 3<\/li>\n<\/ul>\n<h2>\u00dcr\u00fcn Modeli Kodlama Sistemi<\/h2>\n<p>VMM3 serisi, tam konfig\u00fcrasyonlar\u0131 belirtmek i\u00e7in kapsaml\u0131 bir kodlama sistemi kullan\u0131r:<\/p>\n<ul>\n<li><strong>V:<\/strong> \u015eirket kodu (Viox)<\/li>\n<li><strong>M:<\/strong> Kal\u0131pl\u0131 kasa devre kesici<\/li>\n<li><strong>M3:<\/strong> Tasar\u0131m kodu<\/li>\n<li><strong>-:<\/strong> Ay\u0131r\u0131c\u0131<\/li>\n<li><strong>\u25a1:<\/strong> K\u0131rma kapasitesi karakteristik kodu (standart tip i\u00e7in S, daha y\u00fcksek tip i\u00e7in H)<\/li>\n<li><strong>\u25a1:<\/strong> \u00c7er\u00e7eve derecesi\/anma ak\u0131m\u0131<\/li>\n<li><strong>\/:<\/strong> Ay\u0131r\u0131c\u0131<\/li>\n<li><strong>\u25a1:<\/strong> Kutup say\u0131s\u0131 (2P, 3P, 4P)<\/li>\n<li><strong>\u25a1:<\/strong> A\u00e7ma modu (tek manyetik i\u00e7in 2, termal manyetik i\u00e7in 3)<\/li>\n<li><strong>\u25a1:<\/strong> Yay\u0131n kodu (ayr\u0131nt\u0131lar i\u00e7in Tablo 1'e bak\u0131n\u0131z)<\/li>\n<li><strong>\u25a1:<\/strong> Ama\u00e7 kodu (g\u00fc\u00e7 da\u011f\u0131t\u0131m\u0131n\u0131 korumak i\u00e7in 2)<\/li>\n<li><strong>\u25a1:<\/strong> N kutuplu tip (ayr\u0131nt\u0131lar i\u00e7in nota bak\u0131n)<\/li>\n<\/ul>\n<h2>N-kutup Tipleri<\/h2>\n<p>D\u00f6rt kutuplu \u00fcr\u00fcnler i\u00e7in d\u00f6rt tip n\u00f6tr kutup (N kutup) konfig\u00fcrasyonu mevcuttur:<\/p>\n<ul>\n<li>A tipi N kutup: A\u015f\u0131r\u0131 ak\u0131m a\u00e7ma bile\u015fenleri ile donat\u0131lmam\u0131\u015f, her zaman ba\u011fl\u0131<\/li>\n<li>B-tipi N kutbu: A\u015f\u0131r\u0131 ak\u0131m a\u00e7ma bile\u015feni ile donat\u0131lm\u0131\u015ft\u0131r, N kutbu \u00f6nce kapan\u0131r ve di\u011fer kutuplarla birlikte a\u00e7\u0131l\u0131r<\/li>\n<li>C tipi N kutbu: A\u015f\u0131r\u0131 ak\u0131m a\u00e7ma bile\u015feni ile donat\u0131lm\u0131\u015f olan N kutbu, di\u011fer kutuplarla birlikte kapan\u0131r ve a\u00e7\u0131l\u0131r<\/li>\n<li>D tipi N kutuplu: A\u015f\u0131r\u0131 ak\u0131m a\u00e7ma bile\u015feni ile donat\u0131lm\u0131\u015f, her zaman ba\u011fl\u0131<\/li>\n<\/ul>\n<h2>Serbest B\u0131rakma Se\u00e7enekleri (Tablo 1)<\/h2>\n<table border=\"1\">\n<tbody>\n<tr>\n<th>Ek kodu<\/th>\n<th>Elektromanyetik sal\u0131m<\/th>\n<th>\u00c7ift y\u00f6nl\u00fc serbest b\u0131rakma<\/th>\n<\/tr>\n<tr>\n<td>Aksesuar yok<\/td>\n<td>200<\/td>\n<td>300<\/td>\n<\/tr>\n<tr>\n<td>Alarm konta\u011f\u0131<\/td>\n<td>208<\/td>\n<td>308<\/td>\n<\/tr>\n<tr>\n<td>\u015e\u00f6nt tripper<\/td>\n<td>210<\/td>\n<td>310<\/td>\n<\/tr>\n<tr>\n<td>Yard\u0131mc\u0131 kontaklar<\/td>\n<td>220<\/td>\n<td>320<\/td>\n<\/tr>\n<p><!-- Additional rows omitted for brevity --><\/tbody>\n<\/table>\n<h2>\u015eekil Boyut ve Montaj \u00d6l\u00e7\u00fcleri<\/h2>\n<p><a href=\"https:\/\/test.viox.com\/tr\/?attachment_id=5602\" rel=\"attachment wp-att-5602\"><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-5602\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VMM3-400-3P-400A-MCCB02.webp\" alt=\"\" width=\"888\" height=\"370\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VMM3-400-3P-400A-MCCB02.webp 888w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VMM3-400-3P-400A-MCCB02-300x125.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VMM3-400-3P-400A-MCCB02-768x320.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VMM3-400-3P-400A-MCCB02-600x250.webp 600w\" sizes=\"(max-width: 888px) 100vw, 888px\" \/><\/a><\/p>\n<table border=\"1\">\n<thead>\n<tr>\n<th colspan=\"20\">CJMM3-125, 250 g\u00f6r\u00fcn\u00fcm ve montaj boyutlar\u0131 (\u00d6n panel kablolamas\u0131)<\/th>\n<\/tr>\n<tr>\n<th rowspan=\"2\">Model<\/th>\n<th colspan=\"18\">Boyutlar<\/th>\n<th>Kurulum boyutlar\u0131<\/th>\n<\/tr>\n<tr>\n<th>L<\/th>\n<th>W<\/th>\n<th>H<\/th>\n<th>L1<\/th>\n<th>L2<\/th>\n<th>W1<\/th>\n<th>W2<\/th>\n<th>W3<\/th>\n<th>H1<\/th>\n<th>H2<\/th>\n<th>H3<\/th>\n<th>H4<\/th>\n<th>C<\/th>\n<th>E<\/th>\n<th>F<\/th>\n<th>G<\/th>\n<th>G1<\/th>\n<th>A<\/th>\n<th>B<\/th>\n<th>\u03a6d<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>VMM3-125S<\/td>\n<td>150<\/td>\n<td>92<\/td>\n<td>76<\/td>\n<td>251<\/td>\n<td>132<\/td>\n<td>30<\/td>\n<td>&#8211;<\/td>\n<td>&#8211;<\/td>\n<td>95.5<\/td>\n<td>26<\/td>\n<td>18<\/td>\n<td>3<\/td>\n<td>95<\/td>\n<td>49<\/td>\n<td>28<\/td>\n<td>17.5<\/td>\n<td>8<\/td>\n<td>30<\/td>\n<td>129<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<td>VMM3-125H<\/td>\n<td>150<\/td>\n<td>92<\/td>\n<td>76<\/td>\n<td>251<\/td>\n<td>132<\/td>\n<td>30<\/td>\n<td>&#8211;<\/td>\n<td>&#8211;<\/td>\n<td>95.5<\/td>\n<td>26<\/td>\n<td>18<\/td>\n<td>3<\/td>\n<td>95<\/td>\n<td>49<\/td>\n<td>28<\/td>\n<td>17.5<\/td>\n<td>8<\/td>\n<td>30<\/td>\n<td>129<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<td>VMM3-250S<\/td>\n<td>165<\/td>\n<td>106<\/td>\n<td>87<\/td>\n<td>300<\/td>\n<td>144<\/td>\n<td>35<\/td>\n<td>&#8211;<\/td>\n<td>75<\/td>\n<td>110<\/td>\n<td>24<\/td>\n<td>20<\/td>\n<td>3<\/td>\n<td>102<\/td>\n<td>57<\/td>\n<td>24.5<\/td>\n<td>23.5<\/td>\n<td>11.5<\/td>\n<td>35<\/td>\n<td>126<\/td>\n<td>5.5<\/td>\n<\/tr>\n<tr>\n<td>VMM3-250H<\/td>\n<td>165<\/td>\n<td>106<\/td>\n<td>105<\/td>\n<td>300<\/td>\n<td>144<\/td>\n<td>35<\/td>\n<td>142<\/td>\n<td>75<\/td>\n<td>127<\/td>\n<td>24<\/td>\n<td>20<\/td>\n<td>3<\/td>\n<td>102<\/td>\n<td>57<\/td>\n<td>24.5<\/td>\n<td>23.5<\/td>\n<td>11.5<\/td>\n<td>35<\/td>\n<td>126<\/td>\n<td>5.5<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Viox VMM3-400 3P 400A MCCB, sa\u011flam tasar\u0131m\u0131 ve geli\u015fmi\u015f \u00f6zellikleri ile g\u00fcvenilir devre korumas\u0131 sunar. Performans ve g\u00fcvenli\u011fin \u00e7ok \u00f6nemli oldu\u011fu zorlu elektrik ortamlar\u0131 i\u00e7in m\u00fckemmel bir se\u00e7imdir.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<div class=\"msg-content MuiBox-root css-0\">\n<div class=\"break-words\">\n<p>VIOX VMM3-250 MCCB, 250A'e kadar g\u00fc\u00e7 da\u011f\u0131t\u0131m a\u011flar\u0131 i\u00e7in sa\u011flam koruma sa\u011flar. IEC60947-2 uyumlu bu cihaz, 400V AC'de 35kA kesme kapasitesine sahiptir ve 100A ila 250A aras\u0131ndaki ak\u0131m de\u011ferlerini destekler. 2P, 3P ve 4P konfig\u00fcrasyonlar\u0131nda mevcut olan cihaz, 800V yal\u0131t\u0131m gerilimi ile 400V\/690V AC'de \u00e7al\u0131\u015f\u0131r. Temel avantajlar\u0131 aras\u0131nda kompakt boyut, y\u00fcksek kesme kapasitesi ve m\u00fckemmel titre\u015fim \u00f6nleme \u00f6zellikleri yer al\u0131r. \u00c7e\u015fitli uygulamalar i\u00e7in uygun olan bu \u00fcr\u00fcn, ters zamanl\u0131 ve anl\u0131k a\u00e7ma \u00f6zellikleriyle a\u015f\u0131r\u0131 y\u00fck ve k\u0131sa devre korumas\u0131 sunar. 5\u00b0C ila +40\u00b0C aras\u0131nda ve 2000 m y\u00fcksekli\u011fe kadar etkili bir \u015fekilde \u00e7al\u0131\u015fan bu MCCB, zorlu elektrik ortamlar\u0131nda g\u00fcvenilir performans sa\u011flar. \u00c7oklu N-kutup se\u00e7enekleri ve serbest b\u0131rakma konfig\u00fcrasyonlar\u0131 da dahil olmak \u00fczere \u00e7ok y\u00f6nl\u00fc tasar\u0131m\u0131, \u00fcst\u00fcn g\u00fcvenlik \u00f6zellikleri ve uluslararas\u0131 standartlara uygunluk sunarak g\u00fc\u00e7 da\u011f\u0131t\u0131m koruma ihtiya\u00e7lar\u0131 i\u00e7in idealdir.<\/p>\n<\/div>\n<\/div>","protected":false},"featured_media":5605,"comment_status":"closed","ping_status":"closed","template":"","meta":{"inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[],"product_cat":[116,132],"product_tag":[],"class_list":{"0":"post-5604","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-low-voltage-protection-devices","7":"product_cat-mccb","8":"desktop-align-left","9":"tablet-align-left","10":"mobile-align-left","12":"first","13":"instock","14":"shipping-taxable","15":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product\/5604","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/comments?post=5604"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/media\/5605"}],"wp:attachment":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/media?parent=5604"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product_brand?post=5604"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product_cat?post=5604"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product_tag?post=5604"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}