{"id":5603,"date":"2024-09-13T20:28:14","date_gmt":"2024-09-13T12:28:14","guid":{"rendered":"https:\/\/viox.com\/?post_type=product&#038;p=5603"},"modified":"2024-09-13T20:31:41","modified_gmt":"2024-09-13T12:31:41","slug":"viox-vmm3-400-3p-400a-mccb","status":"publish","type":"product","link":"https:\/\/test.viox.com\/tr\/urun\/viox-vmm3-400-3p-400a-mccb\/","title":{"rendered":"VIOX VMM3-400 3P 400A MCCB"},"content":{"rendered":"<div class=\"product-intro\">\n<h2>VIOX VMM3-400 3P 400A Kal\u0131pl\u0131 Kutulu Devre Kesici (MCCB)<\/h2>\n<h2>\u00dcr\u00fcne Genel Bak\u0131\u015f<\/h2>\n<p>Viox VMM3-400, g\u00fc\u00e7 da\u011f\u0131t\u0131m \u015febekelerinde k\u0131sa devre korumas\u0131 i\u00e7in tasarlanm\u0131\u015f y\u00fcksek performansl\u0131 3 kutuplu 400A Kal\u0131pl\u0131 Kutulu Devre Kesicidir. Kompakt boyutu, y\u00fcksek kesme kapasitesi ve \u00e7ok y\u00f6nl\u00fc \u00f6zellikleri ile \u00e7e\u015fitli end\u00fcstriyel ve ticari uygulamalar i\u00e7in ideal bir \u00e7\u00f6z\u00fcmd\u00fcr.<\/p>\n<h2>Temel \u00d6zellikler<\/h2>\n<ul>\n<li><strong>Nominal Ak\u0131m:<\/strong> 400A'e kadar<\/li>\n<li><strong>Direkler:<\/strong> 2P, 3P, 4P konfig\u00fcrasyonlar\u0131nda mevcuttur<\/li>\n<li><strong>Nominal \u00c7al\u0131\u015fma Gerilimi:<\/strong> 400V\/690V AC<\/li>\n<li><strong>Nominal \u0130zolasyon Gerilimi:<\/strong> 800V<\/li>\n<li><strong>K\u0131rma Kapasitesi:<\/strong> Standart (S) ve Y\u00fcksek (H) tipleri mevcuttur<\/li>\n<li><strong>Uyumluluk:<\/strong> IEC60947-2 ve GB\/T14048.2 standartlar\u0131<\/li>\n<\/ul>\n<h2>Teknik \u00d6zellikler<\/h2>\n<p><b>Devre kesici de\u011feri<\/b><\/p>\n<div class=\"table_wrap\">\n<table border=\"0\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"92\" \/>\n<col width=\"109\" \/>\n<col width=\"53\" \/>\n<col width=\"67\" \/>\n<col span=\"3\" width=\"61\" \/>\n<col width=\"75\" \/>\n<col width=\"69\" \/><\/colgroup>\n<tbody>\n<tr>\n<td width=\"92\" height=\"216\">Model<\/td>\n<td width=\"109\">\u00c7er\u00e7eve de\u011ferlendirmesi<br \/>\nnominal ak\u0131m<br \/>\nGiri\u015f (mA)<\/td>\n<td width=\"53\">Derecelendirilmi\u015f<br \/>\ng\u00fcncel<br \/>\nIn(A)<\/td>\n<td width=\"67\">Derecelendirilmi\u015f<br \/>\n\u00e7al\u0131\u015f\u0131yor<br \/>\nGerilim (V)<\/td>\n<td width=\"61\">Derecelendirilmi\u015f<br \/>\n\u0130zolasyon<br \/>\nGerilim (V)<\/td>\n<td width=\"61\">En y\u00fcksek puan<br \/>\nk\u0131sa devre<br \/>\nk\u0131r\u0131lma<br \/>\nkapasite Icu(kA)<\/td>\n<td width=\"61\">Nominal \u00e7al\u0131\u015fma<br \/>\nk\u0131sa devre<br \/>\nk\u0131r\u0131lma<br \/>\nkapasite Ics(kA)<\/td>\n<td width=\"75\">Say\u0131<br \/>\n.<br \/>\nkutuplar<\/td>\n<td width=\"69\">Flashover<br \/>\nmesafe<br \/>\n(mm)<\/td>\n<\/tr>\n<tr>\n<td height=\"18\">VMM3-125S<\/td>\n<td>125<\/td>\n<td rowspan=\"2\" width=\"53\">16,20,25,32,<br \/>\n40,50,60,80,<br \/>\n100,125<\/td>\n<td rowspan=\"2\">400\/415<\/td>\n<td rowspan=\"2\">1000<\/td>\n<td>25<\/td>\n<td>18<\/td>\n<td>3P<\/td>\n<td rowspan=\"2\">\u226450<\/td>\n<\/tr>\n<tr>\n<td height=\"18\">VMM3-125H<\/td>\n<td>125<\/td>\n<td>35<\/td>\n<td>25<\/td>\n<td>3P<\/td>\n<\/tr>\n<tr>\n<td height=\"18\">VMM3-250S<\/td>\n<td>250<\/td>\n<td rowspan=\"2\" width=\"53\">100,125,160,<br \/>\n180,200,225,<br \/>\n250<\/td>\n<td rowspan=\"2\">400\/690<\/td>\n<td>800<\/td>\n<td>35\/10<\/td>\n<td>25\/5<\/td>\n<td rowspan=\"2\">2P,3P,4P<\/td>\n<td rowspan=\"2\">\u226450<\/td>\n<\/tr>\n<tr>\n<td height=\"18\">VMM3-250S<\/td>\n<td>250<\/td>\n<td>600<\/td>\n<td>50<\/td>\n<td>35<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>&nbsp;<\/p>\n<p><b>T\u00fcm kutuplar ayn\u0131 anda enerjilendirildi\u011finde da\u011f\u0131t\u0131m devre kesicisinin a\u015f\u0131r\u0131 ak\u0131m b\u0131rakmas\u0131n\u0131n ters zamanl\u0131 kesme eylemi \u00f6zellikleri<\/b><\/p>\n<div class=\"table_wrap\">\n<table border=\"0\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"235\" \/>\n<col width=\"43\" \/>\n<col width=\"206\" \/>\n<col width=\"395\" \/><\/colgroup>\n<tbody>\n<tr>\n<td width=\"235\" height=\"18\">Ge\u00e7erli ad\u0131 test edin<\/td>\n<td width=\"43\">Ben\/\u0130\u00e7inde<\/td>\n<td width=\"206\">Atanm\u0131\u015f zaman<\/td>\n<td width=\"395\">Ba\u015flang\u0131\u00e7 durumu<\/td>\n<\/tr>\n<tr>\n<td height=\"18\">A\u00e7ma ak\u0131m\u0131 olmad\u0131\u011f\u0131 kabul edildi<\/td>\n<td>1.05<\/td>\n<td>2h(In\uff1e63A),1h(In\u226463A)<\/td>\n<td>So\u011fuk durum<\/td>\n<\/tr>\n<tr>\n<td height=\"18\">Kabul edilen a\u00e7ma ak\u0131m\u0131<\/td>\n<td>1.3<\/td>\n<td>2h(In\uff1e63A),1h(In\u226463A)<\/td>\n<td>Sekans 1 testinden hemen sonra<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>&nbsp;<\/p>\n<p><b>T\u00fcm kutuplara ayn\u0131 anda enerji verildi\u011finde motor korumas\u0131 i\u00e7in devre kesicinin a\u015f\u0131r\u0131 ak\u0131m b\u0131rakmas\u0131n\u0131n ters zamanl\u0131 kesme eylemi \u00f6zellikleri<\/b><\/p>\n<div class=\"table_wrap\">\n<table border=\"0\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"153\" \/>\n<col width=\"143\" \/>\n<col width=\"395\" \/>\n<col width=\"143\" \/><\/colgroup>\n<tbody>\n<tr>\n<td width=\"153\" height=\"18\">Ak\u0131m ayar\u0131<\/td>\n<td width=\"143\">Atanm\u0131\u015f zaman<\/td>\n<td width=\"395\">Ba\u015flang\u0131\u00e7 durumu<\/td>\n<td width=\"143\">A\u00e7\u0131klama<\/td>\n<\/tr>\n<tr>\n<td height=\"18\">1.0In<\/td>\n<td>&gt;2h<\/td>\n<td>So\u011fuk durum<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td height=\"18\">1,2 in\u00e7<\/td>\n<td>\u22642h<\/td>\n<td>Sekans 1 testinden hemen sonra<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" height=\"36\">1,5 in\u00e7<\/td>\n<td>\u22644 dakika<\/td>\n<td>so\u011fuk durum<\/td>\n<td>10 \u2264 In \u2264 250<\/td>\n<\/tr>\n<tr>\n<td>\u22648 dakika<\/td>\n<td>so\u011fuk durum<\/td>\n<td>250 \u2264 In \u2264 630<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" height=\"36\">7.2In<\/td>\n<td>4s\u2264T\u226410s<\/td>\n<td>so\u011fuk durum<\/td>\n<td>10 \u2264 In \u2264 250<\/td>\n<\/tr>\n<tr>\n<td>6s\u2264T\u226420s<\/td>\n<td>so\u011fuk durum<\/td>\n<td>250 \u2264 In \u2264 800<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>Da\u011f\u0131t\u0131m i\u00e7in devre kesicinin anl\u0131k \u00e7al\u0131\u015fma \u00f6zellikleri 10In\u00b120% olarak ayarlan\u0131r ve motor korumas\u0131 i\u00e7in devre kesicinin anl\u0131k \u00e7al\u0131\u015fma \u00f6zellikleri 12In\u00b120% olarak ayarlan\u0131r.<\/p>\n<h2>\u00c7al\u0131\u015fma Ko\u015fullar\u0131<\/h2>\n<ul>\n<li><strong>Y\u00fckseklik:<\/strong> 2000 m'yi a\u015fmayan<\/li>\n<li><strong>Ortam S\u0131cakl\u0131\u011f\u0131:<\/strong> -5\u00b0C ila +40\u00b0C (24 saatlik ortalama +35\u00b0C'yi ge\u00e7memelidir)<\/li>\n<li><strong>Ba\u011f\u0131l Nem:<\/strong> 40\u00b0C'de 50%'yi ge\u00e7memelidir, daha d\u00fc\u015f\u00fck s\u0131cakl\u0131klarda daha y\u00fcksek neme izin verilir<\/li>\n<li><strong>Kirlilik Seviyesi:<\/strong> 3<\/li>\n<\/ul>\n<h2>N-kutup Tipleri<\/h2>\n<p>D\u00f6rt kutuplu \u00fcr\u00fcnler i\u00e7in d\u00f6rt tip n\u00f6tr kutup (N kutup) konfig\u00fcrasyonu mevcuttur:<\/p>\n<ul>\n<li>A tipi N kutup: A\u015f\u0131r\u0131 ak\u0131m a\u00e7ma bile\u015fenleri ile donat\u0131lmam\u0131\u015f, her zaman ba\u011fl\u0131<\/li>\n<li>B-tipi N kutbu: A\u015f\u0131r\u0131 ak\u0131m a\u00e7ma bile\u015feni ile donat\u0131lm\u0131\u015ft\u0131r, N kutbu \u00f6nce kapan\u0131r ve di\u011fer kutuplarla birlikte a\u00e7\u0131l\u0131r<\/li>\n<li>C tipi N kutbu: A\u015f\u0131r\u0131 ak\u0131m a\u00e7ma bile\u015feni ile donat\u0131lm\u0131\u015f olan N kutbu, di\u011fer kutuplarla birlikte kapan\u0131r ve a\u00e7\u0131l\u0131r<\/li>\n<li>D tipi N kutuplu: A\u015f\u0131r\u0131 ak\u0131m a\u00e7ma bile\u015feni ile donat\u0131lm\u0131\u015f, her zaman ba\u011fl\u0131<\/li>\n<\/ul>\n<h2>\u00dcr\u00fcn Modeli Kodlama Sistemi<\/h2>\n<p>VMM3 serisi, tam konfig\u00fcrasyonlar\u0131 belirtmek i\u00e7in kapsaml\u0131 bir kodlama sistemi kullan\u0131r:<\/p>\n<ul>\n<li><strong>V:<\/strong> \u015eirket kodu (Viox)<\/li>\n<li><strong>M:<\/strong> Kal\u0131pl\u0131 kasa devre kesici<\/li>\n<li><strong>M3:<\/strong> Tasar\u0131m kodu<\/li>\n<li><strong>-:<\/strong> Ay\u0131r\u0131c\u0131<\/li>\n<li><strong>\u25a1:<\/strong> K\u0131rma kapasitesi karakteristik kodu (standart tip i\u00e7in S, daha y\u00fcksek tip i\u00e7in H)<\/li>\n<li><strong>\u25a1:<\/strong> \u00c7er\u00e7eve derecesi\/anma ak\u0131m\u0131<\/li>\n<li><strong>\/:<\/strong> Ay\u0131r\u0131c\u0131<\/li>\n<li><strong>\u25a1:<\/strong> Kutup say\u0131s\u0131 (2P, 3P, 4P)<\/li>\n<li><strong>\u25a1:<\/strong> A\u00e7ma modu (tek manyetik i\u00e7in 2, termal manyetik i\u00e7in 3)<\/li>\n<li><strong>\u25a1:<\/strong> Yay\u0131n kodu (ayr\u0131nt\u0131lar i\u00e7in Tablo 1'e bak\u0131n\u0131z)<\/li>\n<li><strong>\u25a1:<\/strong> Ama\u00e7 kodu (g\u00fc\u00e7 da\u011f\u0131t\u0131m\u0131n\u0131 korumak i\u00e7in 2)<\/li>\n<li><strong>\u25a1:<\/strong> N kutuplu tip (ayr\u0131nt\u0131lar i\u00e7in nota bak\u0131n)<\/li>\n<\/ul>\n<h2>Serbest B\u0131rakma Se\u00e7enekleri (Tablo 1)<\/h2>\n<table border=\"1\">\n<tbody>\n<tr>\n<th>Ek kodu<\/th>\n<th>Elektromanyetik sal\u0131m<\/th>\n<th>\u00c7ift y\u00f6nl\u00fc serbest b\u0131rakma<\/th>\n<\/tr>\n<tr>\n<td>Aksesuar yok<\/td>\n<td>200<\/td>\n<td>300<\/td>\n<\/tr>\n<tr>\n<td>Alarm konta\u011f\u0131<\/td>\n<td>208<\/td>\n<td>308<\/td>\n<\/tr>\n<tr>\n<td>\u015e\u00f6nt tripper<\/td>\n<td>210<\/td>\n<td>310<\/td>\n<\/tr>\n<tr>\n<td>Yard\u0131mc\u0131 kontaklar<\/td>\n<td>220<\/td>\n<td>320<\/td>\n<\/tr>\n<p><!-- Additional rows omitted for brevity --><\/tbody>\n<\/table>\n<h2>\u015eekil Boyut ve Montaj \u00d6l\u00e7\u00fcleri<\/h2>\n<p><a href=\"https:\/\/test.viox.com\/tr\/?attachment_id=5602\" rel=\"attachment wp-att-5602\"><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-5602\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VMM3-400-3P-400A-MCCB02.webp\" alt=\"\" width=\"888\" height=\"370\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VMM3-400-3P-400A-MCCB02.webp 888w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VMM3-400-3P-400A-MCCB02-300x125.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VMM3-400-3P-400A-MCCB02-768x320.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VMM3-400-3P-400A-MCCB02-600x250.webp 600w\" sizes=\"(max-width: 888px) 100vw, 888px\" \/><\/a><\/p>\n<table border=\"1\">\n<thead>\n<tr>\n<th colspan=\"20\">CJMM3-125, 250 g\u00f6r\u00fcn\u00fcm ve montaj boyutlar\u0131 (\u00d6n panel kablolamas\u0131)<\/th>\n<\/tr>\n<tr>\n<th rowspan=\"2\">Model<\/th>\n<th colspan=\"18\">Boyutlar<\/th>\n<th>Kurulum boyutlar\u0131<\/th>\n<\/tr>\n<tr>\n<th>L<\/th>\n<th>W<\/th>\n<th>H<\/th>\n<th>L1<\/th>\n<th>L2<\/th>\n<th>W1<\/th>\n<th>W2<\/th>\n<th>W3<\/th>\n<th>H1<\/th>\n<th>H2<\/th>\n<th>H3<\/th>\n<th>H4<\/th>\n<th>C<\/th>\n<th>E<\/th>\n<th>F<\/th>\n<th>G<\/th>\n<th>G1<\/th>\n<th>A<\/th>\n<th>B<\/th>\n<th>\u03a6d<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>VMM3-125S<\/td>\n<td>150<\/td>\n<td>92<\/td>\n<td>76<\/td>\n<td>251<\/td>\n<td>132<\/td>\n<td>30<\/td>\n<td>&#8211;<\/td>\n<td>&#8211;<\/td>\n<td>95.5<\/td>\n<td>26<\/td>\n<td>18<\/td>\n<td>3<\/td>\n<td>95<\/td>\n<td>49<\/td>\n<td>28<\/td>\n<td>17.5<\/td>\n<td>8<\/td>\n<td>30<\/td>\n<td>129<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<td>VMM3-125H<\/td>\n<td>150<\/td>\n<td>92<\/td>\n<td>76<\/td>\n<td>251<\/td>\n<td>132<\/td>\n<td>30<\/td>\n<td>&#8211;<\/td>\n<td>&#8211;<\/td>\n<td>95.5<\/td>\n<td>26<\/td>\n<td>18<\/td>\n<td>3<\/td>\n<td>95<\/td>\n<td>49<\/td>\n<td>28<\/td>\n<td>17.5<\/td>\n<td>8<\/td>\n<td>30<\/td>\n<td>129<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<td>VMM3-250S<\/td>\n<td>165<\/td>\n<td>106<\/td>\n<td>87<\/td>\n<td>300<\/td>\n<td>144<\/td>\n<td>35<\/td>\n<td>&#8211;<\/td>\n<td>75<\/td>\n<td>110<\/td>\n<td>24<\/td>\n<td>20<\/td>\n<td>3<\/td>\n<td>102<\/td>\n<td>57<\/td>\n<td>24.5<\/td>\n<td>23.5<\/td>\n<td>11.5<\/td>\n<td>35<\/td>\n<td>126<\/td>\n<td>5.5<\/td>\n<\/tr>\n<tr>\n<td>VMM3-250H<\/td>\n<td>165<\/td>\n<td>106<\/td>\n<td>105<\/td>\n<td>300<\/td>\n<td>144<\/td>\n<td>35<\/td>\n<td>142<\/td>\n<td>75<\/td>\n<td>127<\/td>\n<td>24<\/td>\n<td>20<\/td>\n<td>3<\/td>\n<td>102<\/td>\n<td>57<\/td>\n<td>24.5<\/td>\n<td>23.5<\/td>\n<td>11.5<\/td>\n<td>35<\/td>\n<td>126<\/td>\n<td>5.5<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Viox VMM3-400 3P 400A MCCB, sa\u011flam tasar\u0131m\u0131 ve geli\u015fmi\u015f \u00f6zellikleri ile g\u00fcvenilir devre korumas\u0131 sunar. Performans ve g\u00fcvenli\u011fin \u00e7ok \u00f6nemli oldu\u011fu zorlu elektrik ortamlar\u0131 i\u00e7in m\u00fckemmel bir se\u00e7imdir.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>VIOX VMM3-400 3P 400A MCCB: G\u00fc\u00e7 da\u011f\u0131t\u0131m \u015febekeleri i\u00e7in y\u00fcksek performansl\u0131 devre kesici. 400A nominal ak\u0131m ile 3 kutuplu tasar\u0131ma sahiptir. 800V nominal yal\u0131t\u0131m gerilimi ile 400V\/690V AC'de \u00e7al\u0131\u015f\u0131r. Standart (S) ve daha y\u00fcksek (H) kesme kapasitesi tiplerinde mevcuttur. IEC60947-2 ve GB\/T14048.2 standartlar\u0131 ile uyumludur. Ters zamanl\u0131 kesme eylemi ve ayarlanabilir anl\u0131k a\u00e7ma ayarlar\u0131 sunar. 2000m'ye kadar y\u00fckseklikler ve -5\u00b0C ila +40\u00b0C aras\u0131 s\u0131cakl\u0131klar i\u00e7in uygundur. D\u00f6rt kutuplu \u00fcr\u00fcnler i\u00e7in \u00e7oklu N-kutup konfig\u00fcrasyonlar\u0131 mevcuttur. Hassas spesifikasyonlar i\u00e7in kapsaml\u0131 model kodlama sistemine sahip kompakt tasar\u0131m. Zorlu elektrik ortamlar\u0131nda g\u00fcvenilir k\u0131sa devre korumas\u0131 ve \u00e7ok y\u00f6nl\u00fc kurulum se\u00e7enekleri gerektiren end\u00fcstriyel ve ticari uygulamalar i\u00e7in idealdir.<\/p>","protected":false},"featured_media":5601,"comment_status":"closed","ping_status":"closed","template":"","meta":{"inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[],"product_cat":[116,132],"product_tag":[],"class_list":{"0":"post-5603","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-low-voltage-protection-devices","7":"product_cat-mccb","8":"desktop-align-left","9":"tablet-align-left","10":"mobile-align-left","12":"first","13":"instock","14":"shipping-taxable","15":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product\/5603","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/comments?post=5603"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/media\/5601"}],"wp:attachment":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/media?parent=5603"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product_brand?post=5603"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product_cat?post=5603"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product_tag?post=5603"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}