{"id":5588,"date":"2024-09-13T16:35:55","date_gmt":"2024-09-13T08:35:55","guid":{"rendered":"https:\/\/viox.com\/?post_type=product&#038;p=5588"},"modified":"2024-09-13T16:39:17","modified_gmt":"2024-09-13T08:39:17","slug":"viox-vrc1-125-b-100a-2p-rccb","status":"publish","type":"product","link":"https:\/\/test.viox.com\/tr\/urun\/viox-vrc1-125-b-100a-2p-rccb\/","title":{"rendered":"VIOX VRC1-125-B 100A 2P RCCB"},"content":{"rendered":"<div class=\"product-intro\">\n<h2>VIOX VRC1-125-B 100A 2P RCCB Ka\u00e7ak Ak\u0131m Devre Kesici<\/h2>\n<h2>Genel Bak\u0131\u015f<\/h2>\n<p>VIOX VRC1-125-B, toprak ar\u0131zalar\u0131na ve elektrik ka\u00e7a\u011f\u0131na kar\u015f\u0131 \u00fcst\u00fcn koruma i\u00e7in tasarlanm\u0131\u015f y\u00fcksek performansl\u0131 bir Ka\u00e7ak Ak\u0131m Devre Kesicidir (RCCB). Geli\u015fmi\u015f \u00f6zellikleri ve g\u00fcvenilir performans\u0131 ile bu RCCB, \u00e7e\u015fitli elektrik tesisatlar\u0131nda geli\u015fmi\u015f g\u00fcvenlik sa\u011flar.<\/p>\n<h2>Temel \u00d6zellikler<\/h2>\n<ul>\n<li>Rahat kullan\u0131m i\u00e7in ergonomik bombeli kapak ve tutamak<\/li>\n<li>Kolay durum kontrol\u00fc i\u00e7in kontak konumu g\u00f6sterge penceresi<\/li>\n<li>Net tan\u0131mlama i\u00e7in etiketli \u015feffaf kapakl\u0131<\/li>\n<li>Orta konuma a\u00e7\u0131lan kol ile h\u0131zl\u0131 ar\u0131za tespiti<\/li>\n<li>Toprak hatas\u0131, elektrik ka\u00e7a\u011f\u0131 ve izolasyon koruma fonksiyonlar\u0131<\/li>\n<li>Y\u00fcksek k\u0131sa devre ak\u0131m tolerans\u0131<\/li>\n<li>Daha fazla g\u00fcvenlik i\u00e7in parmak korumal\u0131 kablo terminali<\/li>\n<li>Y\u00fcksek alev dayan\u0131ml\u0131, s\u0131cakl\u0131\u011fa dayan\u0131kl\u0131 ve darbeye dayan\u0131kl\u0131 m\u00fchendislik plasti\u011fi yap\u0131<\/li>\n<li>Toprak ar\u0131zas\u0131 veya elektrik ka\u00e7a\u011f\u0131 \u00f6ng\u00f6r\u00fclen de\u011feri a\u015ft\u0131\u011f\u0131nda otomatik devre kesme<\/li>\n<li>Ba\u011f\u0131ms\u0131z dinamik ve tel bas\u0131nc\u0131, harici bozukluklardan ve voltaj dalgalanmalar\u0131ndan etkilenmez<\/li>\n<\/ul>\n<h2>Teknik \u00d6zellikler<\/h2>\n<ul>\n<li>Standart: IEC61008-1, IEC62423<\/li>\n<li>Tip: Elektronik tip (Yard\u0131mc\u0131 Elektromanyetik tip)<\/li>\n<li>Art\u0131k \u00e7al\u0131\u015fma ak\u0131m\u0131n\u0131n \u00f6zellikleri: Tip B<\/li>\n<li>Direkler: 2P (1P+N, 3P+N mevcuttur)<\/li>\n<li>Nominal \u00e7al\u0131\u015fma kesme kapasitesi: 10 InA<\/li>\n<li>Nominal ak\u0131m: 100A (25A, 40A, 63A da mevcuttur)<\/li>\n<li>Nominal gerilim: AC 240\/415V<\/li>\n<li>Nominal frekans: 50\/60 Hz<\/li>\n<li>Nominal art\u0131k \u00e7al\u0131\u015fma ak\u0131m\u0131 (I\u25b3n): 0.03A, 0.1A, 0.3A<\/li>\n<li>Nominal art\u0131k \u00e7al\u0131\u015fmayan ak\u0131m: 0,5I\u25b3n<\/li>\n<li>Nominal s\u0131n\u0131rl\u0131 k\u0131sa devre ak\u0131m\u0131: 10 kA<\/li>\n<li>Nominal s\u0131n\u0131rl\u0131 art\u0131k k\u0131sa devre ak\u0131m\u0131: 10 kA<\/li>\n<li>Art\u0131k \u00e7al\u0131\u015fma ak\u0131m\u0131n\u0131n kapsam\u0131: 0,5I\u25b3n~I\u25b3n<\/li>\n<li>Mekanik elektrik \u00f6mr\u00fc: 4.000 d\u00f6ng\u00fc<\/li>\n<li>Terminalin kablolama b\u00f6l\u00fcm\u00fc alan\u0131: 25 mm\u00b2 ve alt\u0131 iletken<\/li>\n<li>Kurulum: 35,5 mm k\u0131lavuz ray \/ Dikey kurulum<\/li>\n<li>Muhafaza koruma s\u0131n\u0131f\u0131: IP20<\/li>\n<\/ul>\n<div class=\"table_wrap\">\n<h2><b>Temel Parametreler<\/b><\/h2>\n<table border=\"0\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"136\" \/>\n<col width=\"268\" \/>\n<col width=\"243\" \/>\n<col width=\"173\" \/>\n<col width=\"58\" \/>\n<col width=\"66\" \/>\n<col width=\"217\" \/>\n<col width=\"69\" \/><\/colgroup>\n<tbody>\n<tr>\n<td width=\"136\" height=\"81\">Nominal ak\u0131m<br \/>\nkonutlar\u0131n<br \/>\ns\u0131n\u0131f Inm(A)<\/td>\n<td width=\"268\">Kutuplar<\/td>\n<td width=\"243\">Frekans<br \/>\n(Hz)<\/td>\n<td width=\"173\">Anma gerilimi<br \/>\nUe(V)<\/td>\n<td width=\"58\">Nominal ak\u0131m<br \/>\nIn(A)<\/td>\n<td width=\"66\">Nominal kal\u0131nt\u0131<br \/>\nak\u0131m (A)<\/td>\n<td width=\"217\">S\u0131n\u0131rl\u0131 puan<br \/>\nk\u0131sa devre<br \/>\nmevcut Inc(A)<\/td>\n<td width=\"69\">S\u0131n\u0131rl\u0131 puan<br \/>\nart\u0131k k\u0131sa<br \/>\ndevre ak\u0131m\u0131<br \/>\nI\u25b3C(A)<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" height=\"36\">63<\/td>\n<td>1P+N<\/td>\n<td rowspan=\"2\">50\/60Hz<\/td>\n<td align=\"right\">240<\/td>\n<td rowspan=\"2\">25 40 63<\/td>\n<td rowspan=\"2\">0.03 0.1 0.3<\/td>\n<td rowspan=\"2\">10000<\/td>\n<td rowspan=\"2\">10000<\/td>\n<\/tr>\n<tr>\n<td>3P+N<\/td>\n<td align=\"right\">415<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>&nbsp;<\/p>\n<p><b>Do\u011frultma devresi taraf\u0131ndan \u00fcretilen darbeli DC art\u0131k ak\u0131m ve d\u00fczg\u00fcn DC art\u0131k ak\u0131m i\u00e7in kesme s\u00fcresi ve \u00e7al\u0131\u015fmama s\u00fcresinin standart de\u011feri<\/b><\/p>\n<div class=\"table_wrap\">\n<table border=\"0\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"136\" \/>\n<col width=\"268\" \/>\n<col width=\"243\" \/>\n<col width=\"173\" \/>\n<col width=\"58\" \/>\n<col width=\"66\" \/>\n<col width=\"217\" \/><\/colgroup>\n<tbody>\n<tr>\n<td rowspan=\"2\" width=\"136\" height=\"78\">Tip<\/td>\n<td rowspan=\"2\" width=\"268\">In(A)<\/td>\n<td rowspan=\"2\" width=\"243\">I\u25b3n(A)<\/td>\n<td colspan=\"4\" width=\"514\">Kal\u0131nt\u0131 e\u015fitli\u011fi i\u00e7in k\u0131r\u0131lma s\u00fcresi ve \u00e7al\u0131\u015fmama s\u00fcresinin standart de\u011feri<br \/>\nak\u0131m (I\u25b3A ) ve a\u015fa\u011f\u0131daki de\u011ferler (S)<\/td>\n<\/tr>\n<tr>\n<td>2 I\u25b3n<\/td>\n<td>4 I\u25b3n<\/td>\n<td>10 I\u25b3n<\/td>\n<td>5A,10A,20A,50A,100A,200A<\/td>\n<\/tr>\n<tr>\n<td height=\"18\">Genel tip<\/td>\n<td>Herhangi bir de\u011fer<\/td>\n<td>Herhangi bir de\u011fer<\/td>\n<td>0.3<\/td>\n<td>0.15<\/td>\n<td>0.04<\/td>\n<td>0.04<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>&nbsp;<\/p>\n<p><b>A\u00e7ma ak\u0131m\u0131 aral\u0131\u011f\u0131 (Tablo 1)<\/b><\/p>\n<div class=\"table_wrap\">\n<table border=\"0\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"136\" \/>\n<col width=\"268\" \/>\n<col width=\"243\" \/>\n<col width=\"173\" \/><\/colgroup>\n<tbody>\n<tr>\n<td width=\"136\" height=\"18\">Model<\/td>\n<td colspan=\"3\" width=\"684\">A\u00e7ma ak\u0131m\u0131 I\u25b3 \/A<\/td>\n<\/tr>\n<tr>\n<td height=\"18\">AC<\/td>\n<td colspan=\"3\">0,5 I\u25b3n\uff1cI\u25b3n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\" height=\"72\">A<\/td>\n<td>Gecikme a\u00e7\u0131s\u0131<\/td>\n<td>I\u25b3n&gt;0,01A<\/td>\n<td>I\u25b3n\uff1c0,01A<\/td>\n<\/tr>\n<tr>\n<td>0\u00b0<\/td>\n<td>0,35I\u25b3n\u2264I\u25b3\u22641,4I\u25b3n<\/td>\n<td>0,35I\u25b3n\u2264I\u25b3\u22642I\u25b3n<\/td>\n<\/tr>\n<tr>\n<td>90\u00b0<\/td>\n<td>0,25I\u25b3n\u2264I\u25b3\u22641,4I\u25b3n<\/td>\n<td>0,25I\u25b3n\u2264I\u25b3\u22642I\u25b3n<\/td>\n<\/tr>\n<tr>\n<td>135\u00b0<\/td>\n<td>0,1I\u25b3n\u2264I\u25b3\u22641,4I\u25b3n<\/td>\n<td>0,1I\u25b3n\u2264I\u25b3\u22642I\u25b3n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>&nbsp;<\/p>\n<p><b>Frekansa g\u00f6re 50\/60 Hz (B tipi)'den farkl\u0131 (Tablo 2)<\/b><\/p>\n<div class=\"table_wrap\">\n<table border=\"0\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"136\" \/>\n<col width=\"268\" \/>\n<col width=\"243\" \/><\/colgroup>\n<tbody>\n<tr>\n<td width=\"136\" height=\"18\">Frekans (Hz)<\/td>\n<td width=\"268\">Art\u0131k faaliyet d\u0131\u015f\u0131 ak\u0131m<\/td>\n<td width=\"243\">Art\u0131k i\u015fletme ak\u0131m\u0131<\/td>\n<\/tr>\n<tr>\n<td height=\"18\">150<\/td>\n<td>0,5I\u25b3n<\/td>\n<td>2.4I\u25b3n<\/td>\n<\/tr>\n<tr>\n<td height=\"18\">400<\/td>\n<td>0,5I\u25b3n<\/td>\n<td>6I\u25b3n<\/td>\n<\/tr>\n<tr>\n<td height=\"18\">1000<\/td>\n<td>I\u25b3n<\/td>\n<td>14I\u25b3n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2>Uygulamalar<\/h2>\n<ul>\n<li>Konut elektrik sistemleri<\/li>\n<li>Ticari binalar<\/li>\n<li>End\u00fcstriyel tesisler<\/li>\n<li>Da\u011f\u0131t\u0131m panolar\u0131<\/li>\n<li>\u00c7e\u015fitli elektrik devrelerinde toprak ka\u00e7a\u011f\u0131 korumas\u0131<\/li>\n<\/ul>\n<h2>Avantajlar<\/h2>\n<ul>\n<li>\u00c7oklu koruma fonksiyonlar\u0131 ile geli\u015ftirilmi\u015f g\u00fcvenlik<\/li>\n<li>Geli\u015fmi\u015f g\u00fcvenilirlik i\u00e7in y\u00fcksek k\u0131sa devre ak\u0131m\u0131 tolerans\u0131<\/li>\n<li>Kolay kurulum ve bak\u0131m<\/li>\n<li>H\u0131zl\u0131 ar\u0131za tespiti i\u00e7in net durum g\u00f6stergesi<\/li>\n<li>Uzun \u00f6m\u00fcrl\u00fc performans i\u00e7in dayan\u0131kl\u0131 yap\u0131<\/li>\n<li>Kalite g\u00fcvencesi i\u00e7in uluslararas\u0131 standartlarla uyumlu<\/li>\n<\/ul>\n<h2>G\u00fcvenlik \u00d6zellikleri<\/h2>\n<ul>\n<li>Toprak ar\u0131za korumas\u0131<\/li>\n<li>Elektrik ka\u00e7a\u011f\u0131 korumas\u0131<\/li>\n<li>\u0130zolasyon korumas\u0131<\/li>\n<li>Parmak korumal\u0131 kablo terminali<\/li>\n<li>\u00d6ng\u00f6r\u00fclen de\u011ferleri a\u015fan ar\u0131zalar i\u00e7in otomatik devre kesme<\/li>\n<\/ul>\n<h2>Kalite G\u00fcvence<\/h2>\n<p>VIOX, uluslararas\u0131 standartlar\u0131 kar\u015f\u0131layan y\u00fcksek kaliteli RCCB'ler sa\u011flamay\u0131 taahh\u00fct eder. \u00dcr\u00fcnlerimiz, \u00e7e\u015fitli elektrik tesisatlar\u0131nda g\u00fcvenilirlik, g\u00fcvenlik ve uzun vadeli performans sa\u011flamak i\u00e7in titiz testlerden ge\u00e7mektedir.<\/p>\n<h2>Kurulum<\/h2>\n<p>VIOX VRC1-125-B RCCB, 35,5 mm k\u0131lavuz raylara veya dikey montaja kolay kurulum i\u00e7in tasarlanm\u0131\u015ft\u0131r. Kompakt tasar\u0131m\u0131 ve net etiketlemesi, da\u011f\u0131t\u0131m panolar\u0131nda ve elektrik panolar\u0131nda h\u0131zl\u0131 ve verimli kurulumu kolayla\u015ft\u0131r\u0131r.<\/p>\n<h2>Boyut<\/h2>\n<h2>VRC1-125\uff0863A\uff09<\/h2>\n<p><a href=\"https:\/\/test.viox.com\/tr\/?attachment_id=5589\" rel=\"attachment wp-att-5590\"><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone wp-image-5589 size-full\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VRC1-125-B-100A-2P-RCCB-Residual-Current-Circuit-Breaker03.webp\" alt=\"\" width=\"1556\" height=\"528\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VRC1-125-B-100A-2P-RCCB-Residual-Current-Circuit-Breaker03.webp 1556w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VRC1-125-B-100A-2P-RCCB-Residual-Current-Circuit-Breaker03-300x102.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VRC1-125-B-100A-2P-RCCB-Residual-Current-Circuit-Breaker03-1024x347.webp 1024w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VRC1-125-B-100A-2P-RCCB-Residual-Current-Circuit-Breaker03-768x261.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VRC1-125-B-100A-2P-RCCB-Residual-Current-Circuit-Breaker03-1536x521.webp 1536w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VRC1-125-B-100A-2P-RCCB-Residual-Current-Circuit-Breaker03-600x204.webp 600w\" sizes=\"(max-width: 1556px) 100vw, 1556px\" \/><\/a><\/p>\n<h2>VRC1-125\uff08100A\uff09<\/h2>\n<p><a href=\"https:\/\/test.viox.com\/tr\/?attachment_id=5590\" rel=\"attachment wp-att-5590\"><img decoding=\"async\" class=\"alignnone size-full wp-image-5590\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VRC1-125-B-100A-2P-RCCB-Residual-Current-Circuit-Breaker02.webp\" alt=\"\" width=\"1594\" height=\"566\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VRC1-125-B-100A-2P-RCCB-Residual-Current-Circuit-Breaker02.webp 1594w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VRC1-125-B-100A-2P-RCCB-Residual-Current-Circuit-Breaker02-300x107.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VRC1-125-B-100A-2P-RCCB-Residual-Current-Circuit-Breaker02-1024x364.webp 1024w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VRC1-125-B-100A-2P-RCCB-Residual-Current-Circuit-Breaker02-768x273.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VRC1-125-B-100A-2P-RCCB-Residual-Current-Circuit-Breaker02-1536x545.webp 1536w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VRC1-125-B-100A-2P-RCCB-Residual-Current-Circuit-Breaker02-600x213.webp 600w\" sizes=\"(max-width: 1594px) 100vw, 1594px\" \/><\/a><\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<div class=\"msg-content MuiBox-root css-0\">\n<div class=\"break-words\">\n<p>VIOX VRC1-125-B RCCB, 100A'e kadar olan sistemler i\u00e7in toprak ar\u0131zalar\u0131na ve elektrik ka\u00e7a\u011f\u0131na kar\u015f\u0131 \u00fcst\u00fcn koruma sa\u011flar. Bu IEC61008-1 ve IEC62423 uyumlu cihaz, 10kA nominal s\u0131n\u0131rl\u0131 k\u0131sa devre ak\u0131m\u0131na sahiptir ve 0,03A, 0,1A ve 0,3A art\u0131k \u00e7al\u0131\u015fma ak\u0131mlar\u0131n\u0131 destekler. 2P konfig\u00fcrasyonunda mevcut olup 240\/415V AC, 50\/60Hz'de \u00e7al\u0131\u015f\u0131r. Temel avantajlar\u0131 aras\u0131nda Tip B \u00f6zellikleri, IP20 korumas\u0131 ve 4.000 \u00e7evrimlik mekanik \u00f6m\u00fcr yer al\u0131r. Ergonomik tasar\u0131m\u0131, kontak konumu g\u00f6stergesi ve parmak korumal\u0131 terminalleri ile bu RCCB kolay kullan\u0131m ve geli\u015fmi\u015f g\u00fcvenlik sa\u011flar. Konut, ticari ve end\u00fcstriyel uygulamalar i\u00e7in uygun olan bu cihaz, otomatik devre kesme ve y\u00fcksek k\u0131sa devre tolerans\u0131 sunar. Cihaz\u0131n aleve ve darbeye dayan\u0131kl\u0131 yap\u0131s\u0131, 25 mm\u00b2 terminal kapasitesi ve 35,5 mm DIN ray montaj\u0131 ile birle\u015fti\u011finde, da\u011f\u0131t\u0131m panolar\u0131nda ve elektrik devrelerinde \u00e7e\u015fitli toprak ka\u00e7a\u011f\u0131 koruma ihtiya\u00e7lar\u0131 i\u00e7in idealdir.<\/p>\n<\/div>\n<\/div>","protected":false},"featured_media":5591,"comment_status":"closed","ping_status":"closed","template":"","meta":{"inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[],"product_cat":[116,131],"product_tag":[],"class_list":{"0":"post-5588","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-low-voltage-protection-devices","7":"product_cat-rccb","8":"desktop-align-left","9":"tablet-align-left","10":"mobile-align-left","12":"first","13":"instock","14":"shipping-taxable","15":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product\/5588","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/comments?post=5588"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/media\/5591"}],"wp:attachment":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/media?parent=5588"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product_brand?post=5588"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product_cat?post=5588"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product_tag?post=5588"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}