{"id":5470,"date":"2024-09-12T17:01:32","date_gmt":"2024-09-12T09:01:32","guid":{"rendered":"https:\/\/viox.com\/?post_type=product&#038;p=5470"},"modified":"2024-09-12T17:06:00","modified_gmt":"2024-09-12T09:06:00","slug":"viox-vsp1-c40-2s-pluggable-single-pole-spd","status":"publish","type":"product","link":"https:\/\/test.viox.com\/tr\/urun\/viox-vsp1-c40-2s-pluggable-single-pole-spd\/","title":{"rendered":"VIOX VSP1-C40\/2(S) Tak\u0131labilir Tek Kutuplu SPD"},"content":{"rendered":"<div class=\"product-intro\">\n<h2>VIOX VSP1-C40\/2(S) Pluggable Single-Pole SPD<\/h2>\n<h2>Overview<\/h2>\n<p>The VIOX VSP1-C40\/2(S) is a high-performance Pluggable Single-Pole Surge Protective Device (SPD) designed for use in sub-distribution boards. This versatile device offers robust protection for L-PE and N-PE modes, making it an ideal solution for various electrical installations.<\/p>\n<h2>Key Features<\/h2>\n<ul>\n<li>Class II, Type 2, Type 1CA device<\/li>\n<li>Location of Use: Sub-Distribution Boards<\/li>\n<li>Mode of Protection: L-PE, N-PE<\/li>\n<li>Surge Ratings: In = 20 kA (8\/20 \u03bcs)<\/li>\n<li>IEC\/EN\/UL Category: Class II \/ Type 2 \/ Type 1CA<\/li>\n<li>Protective Elements: High Energy MOV<\/li>\n<li>Housing: Pluggable Design<\/li>\n<li>Compliance: IEC 61643-11:2011, EN 61643-11:2012<\/li>\n<\/ul>\n<h2>Technical Specifications<\/h2>\n<table border=\"1\" cellpadding=\"5\">\n<tbody>\n<tr>\n<th>IEC Electrical<\/th>\n<th>75<\/th>\n<th>150<\/th>\n<th>275<\/th>\n<th>320<\/th>\n<th>385<\/th>\n<th>440<\/th>\n<\/tr>\n<tr>\n<td>Nominal AC Voltage (50\/60Hz)<\/td>\n<td>60 V<\/td>\n<td>120 V<\/td>\n<td>230 V<\/td>\n<td>230 V<\/td>\n<td>230 V<\/td>\n<td>400 V<\/td>\n<\/tr>\n<tr>\n<td>Maximum Continuous Operating Voltage (AC)<\/td>\n<td>75 V<\/td>\n<td>150 V<\/td>\n<td>275V<\/td>\n<td>320 V<\/td>\n<td>385 V<\/td>\n<td>440 V<\/td>\n<\/tr>\n<tr>\n<td>Nominal Discharge Current (8\/20 \u03bcs)<\/td>\n<td>20 kA<\/td>\n<td>20 kA<\/td>\n<td>20 kA<\/td>\n<td>20 kA<\/td>\n<td>20 kA<\/td>\n<td>20 kA<\/td>\n<\/tr>\n<tr>\n<td>Maximum Discharge Current (8\/20 \u03bcs)<\/td>\n<td>40 kA<\/td>\n<td>40 kA<\/td>\n<td>40 kA<\/td>\n<td>40 kA<\/td>\n<td>40 kA<\/td>\n<td>40 kA<\/td>\n<\/tr>\n<tr>\n<td>Voltage Protection Level<\/td>\n<td>0.4 kV<\/td>\n<td>1 kV<\/td>\n<td>1.5 kV<\/td>\n<td>1.6 kV<\/td>\n<td>1.8 kV<\/td>\n<td>2 kV<\/td>\n<\/tr>\n<tr>\n<td>Impulse Current (10\/350\u03bcs) Iimp (L-N)<\/td>\n<td colspan=\"6\">7kA<\/td>\n<\/tr>\n<tr>\n<td>Response Time<\/td>\n<td colspan=\"6\">&lt; 25 ns<\/td>\n<\/tr>\n<tr>\n<td>Back-Up Fuse (max)<\/td>\n<td colspan=\"6\">125 A gL \/ gG<\/td>\n<\/tr>\n<tr>\n<td>Short-Circuit Current Rating (AC)<\/td>\n<td colspan=\"6\">25 kA \/ 50 kA<\/td>\n<\/tr>\n<tr>\n<td>TOV Withstand 5s<\/td>\n<td>90V<\/td>\n<td>180V<\/td>\n<td>335V<\/td>\n<td>335V<\/td>\n<td>335V<\/td>\n<td>580V<\/td>\n<\/tr>\n<tr>\n<td>TOV 120min<\/td>\n<td>115V<\/td>\n<td>230V<\/td>\n<td>440V<\/td>\n<td>440V<\/td>\n<td>440V<\/td>\n<td>765V<\/td>\n<\/tr>\n<tr>\n<td>mode<\/td>\n<td>Withstand<\/td>\n<td>Withstand<\/td>\n<td>Safe Fail<\/td>\n<td>Safe Fail<\/td>\n<td>Safe Fail<\/td>\n<td>Safe Fail<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Mechanical &amp; Environmental Specifications<\/h2>\n<ul>\n<li>Operating Temperature Range: -40\u00b0F to +158\u00b0F [-40\u00b0C to +70\u00b0C]<\/li>\n<li>Permissible Operating Humidity: 5%&#8230;95%<\/li>\n<li>Atmospheric pressure and altitude: 80k Pa &#8230; 106k Pa \/ -500 m&#8230;.2000 m<\/li>\n<li>Terminal Screw Torque: 39.9 lbf.in [4.5 Nm]<\/li>\n<li>Conductor Cross Section (max): 2 AWG (Solid, Stranded) \/ 4 AWG (Flexible)<\/li>\n<li>35 mm\u00b2 (Solid, Stranded) \/ 25 mm\u00b2(Flexible)<\/li>\n<li>Mounting: 35 mm DIN Rail, EN 60715<\/li>\n<li>Degree of Protection: IP 20 (built-in)<\/li>\n<li>Housing Material: Thermoplastic: Extinguishing Degree UL 94 V-0<\/li>\n<li>Thermal Protection: Yes<\/li>\n<li>Operating State \/ Fault Indication: Green ok \/ Red defect<\/li>\n<\/ul>\n<h2>Additional Features<\/h2>\n<ul>\n<li>Remote Contacts (RC): Optional<\/li>\n<li>RC Switching Capacity: AC: 250V \/ 0.5 A; DC: 250V \/ 0.1 A;125V \/ 0.2 A;75V \/ 0.5 A<\/li>\n<li>RC Conductor Cross Section (max): 16 AWG (Solid) \/ 1.5 mm\u00b2(Solid)<\/li>\n<\/ul>\n<h2>Internal Configuration<\/h2>\n<p><a href=\"https:\/\/test.viox.com\/?attachment_id=5473\" rel=\"attachment wp-att-5473\"><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-5473\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VSP1-C40_2S-Pluggable-Single-Pole-SPD04.webp\" alt=\"\" width=\"330\" height=\"404\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VSP1-C40_2S-Pluggable-Single-Pole-SPD04.webp 330w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VSP1-C40_2S-Pluggable-Single-Pole-SPD04-245x300.webp 245w\" sizes=\"(max-width: 330px) 100vw, 330px\" \/><\/a><\/p>\n<h2>Dimension<\/h2>\n<p><a href=\"https:\/\/test.viox.com\/?attachment_id=5472\" rel=\"attachment wp-att-5472\"><img decoding=\"async\" class=\"alignnone size-full wp-image-5472\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VSP1-C40_2S-Pluggable-Single-Pole-SPD03.webp\" alt=\"\" width=\"708\" height=\"366\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VSP1-C40_2S-Pluggable-Single-Pole-SPD03.webp 708w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VSP1-C40_2S-Pluggable-Single-Pole-SPD03-300x155.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VSP1-C40_2S-Pluggable-Single-Pole-SPD03-600x310.webp 600w\" sizes=\"(max-width: 708px) 100vw, 708px\" \/><\/a><\/p>\n<h2>Connection Diagram<\/h2>\n<p><a href=\"https:\/\/test.viox.com\/?attachment_id=5474\" rel=\"attachment wp-att-5474\"><img decoding=\"async\" class=\"alignnone size-full wp-image-5474\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VSP1-C40_2S-Pluggable-Single-Pole-SPD02.webp\" alt=\"\" width=\"400\" height=\"402\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VSP1-C40_2S-Pluggable-Single-Pole-SPD02.webp 400w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VSP1-C40_2S-Pluggable-Single-Pole-SPD02-150x150.webp 150w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VSP1-C40_2S-Pluggable-Single-Pole-SPD02-100x100.webp 100w\" sizes=\"(max-width: 400px) 100vw, 400px\" \/><\/a><\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<div class=\"msg-content MuiBox-root css-0\">\n<div class=\"break-words\">\n<p>VIOX VSP1-C40\/2(S) Tak\u0131labilir Tek Kutuplu SPD, alt da\u011f\u0131t\u0131m panolar\u0131 i\u00e7in sa\u011flam a\u015f\u0131r\u0131 gerilim korumas\u0131 sunar. Bu S\u0131n\u0131f II\/Tip 2\/Tip 1CA cihaz, 20kA nominal ve 40kA maksimum de\u015farj ak\u0131m\u0131 ile L-PE ve N-PE modlar\u0131n\u0131 korur. Y\u00fcksek enerjili MOV elemanlar\u0131na sahip olan bu cihaz, 60V ila 400V AC aras\u0131nda &lt;25ns tepki s\u00fcresiyle \u00e7al\u0131\u015f\u0131r. Tak\u0131labilir tasar\u0131m, 35 mm DIN raylar\u0131na kolay kurulum sa\u011flar. IEC 61643-11:2011 ve EN 61643-11:2012 uyumludur, 0,4kV ila 2kV aras\u0131nda voltaj koruma seviyeleri sa\u011flar. IP20 korumas\u0131, termal korumalar\u0131 ve iste\u011fe ba\u011fl\u0131 uzak kontaklar\u0131 ile bu \u00e7ok y\u00f6nl\u00fc SPD, zorlu uygulamalarda geli\u015fmi\u015f g\u00fc\u00e7 sistemi korumas\u0131 i\u00e7in g\u00fcvenilirlik ve performans\u0131 kompakt, kullan\u0131c\u0131 dostu bir pakette birle\u015ftirerek \u00e7e\u015fitli elektrik tesisatlar\u0131na uygundur.<\/p>\n<\/div>\n<\/div>","protected":false},"featured_media":5471,"comment_status":"closed","ping_status":"closed","template":"","meta":{"inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[],"product_cat":[116,127],"product_tag":[],"class_list":{"0":"post-5470","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-low-voltage-protection-devices","7":"product_cat-surge-protector","8":"desktop-align-left","9":"tablet-align-left","10":"mobile-align-left","12":"first","13":"instock","14":"shipping-taxable","15":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product\/5470","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/comments?post=5470"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/media\/5471"}],"wp:attachment":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/media?parent=5470"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product_brand?post=5470"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product_cat?post=5470"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product_tag?post=5470"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}