{"id":20932,"date":"2025-12-22T20:59:32","date_gmt":"2025-12-22T12:59:32","guid":{"rendered":"https:\/\/viox.com\/?post_type=product&#038;p=20932"},"modified":"2025-12-22T21:02:41","modified_gmt":"2025-12-22T13:02:41","slug":"vopv1000-3-3-independent-circuit-solar-combiner-box-3-in-3-out","status":"publish","type":"product","link":"https:\/\/test.viox.com\/tr\/urun\/vopv1000-3-3-independent-circuit-solar-combiner-box-3-in-3-out\/","title":{"rendered":"VOPV1000-3\/3 Solar Birle\u015ftirme Kutusu"},"content":{"rendered":"<div class=\"product-intro\">VIOX Electric, k\u00fcresel pazar i\u00e7in y\u00fcksek kaliteli solar fotovoltaik \u00e7\u00f6z\u00fcmler konusunda uzmanla\u015fm\u0131\u015f, yenilenebilir enerji elektrikli ekipmanlar\u0131n\u0131n \u00f6nde gelen \u00fcreticisidir. VOPV1000-3\/3 Solar Birle\u015ftirme Kutumuz, eksiksiz devre ba\u011f\u0131ms\u0131zl\u0131\u011f\u0131, \u00e7oklu invert\u00f6r \u00f6zelli\u011fi ve maksimum operasyonel esneklik gerektiren geli\u015fmi\u015f DC1000V solar sistemler i\u00e7in \u00f6zel olarak tasarlanm\u0131\u015f birinci s\u0131n\u0131f bir \u00e7oklu devre \u00e7\u00f6z\u00fcm\u00fcn\u00fc temsil etmektedir. VOPV1000-3\/3, DC1000V'de \u00e7al\u0131\u015fan y\u00fcksek voltajl\u0131 solar PV sistemleri i\u00e7in tasarlanm\u0131\u015f profesyonel s\u0131n\u0131f bir DC birle\u015ftirme kutusudur. Bu geli\u015fmi\u015f 3 giri\u015fli, 3 \u00e7\u0131k\u0131\u015fl\u0131 konfig\u00fcrasyon, <strong>\u00fc\u00e7 tamamen ba\u011f\u0131ms\u0131z devreye<\/strong>, her biri \u00f6zel koruma ve kontrol cihazlar\u0131na sahiptir. Birle\u015fik konfig\u00fcrasyonlar\u0131n aksine, 3\/3 mimarisi diziler aras\u0131nda tam izolasyonu korur, bu da onu \u00e7oklu invert\u00f6r sistemleri, \u00e7oklu MPPT uygulamalar\u0131, \u00fc\u00e7 fazl\u0131 kurulumlar ve devre ba\u011f\u0131ms\u0131zl\u0131\u011f\u0131 yoluyla maksimum g\u00fcvenlik gerektiren projeler i\u00e7in ideal hale getirir.<\/p>\n<h2>Temel \u00d6zellikler ve Avantajlar<\/h2>\n<ul>\n<li><strong>\u00dc\u00e7 Ba\u011f\u0131ms\u0131z Devre<\/strong>: \u00dc\u00e7 dize aras\u0131nda tam elektriksel izolasyon \u2013 her birinin kendi korumas\u0131 ve \u00e7\u0131k\u0131\u015f\u0131 vard\u0131r<\/li>\n<li><strong>\u00c7oklu \u0130nvert\u00f6r Haz\u0131r<\/strong>: Birden fazla invert\u00f6re veya \u00e7oklu MPPT giri\u015fli invert\u00f6rlere sahip sistemler i\u00e7in m\u00fckemmeldir<\/li>\n<li><strong>Maksimum Devre Ba\u011f\u0131ms\u0131zl\u0131\u011f\u0131<\/strong>: Her dize, \u00f6zel anahtar, SPD ve sigortalarla tamamen ba\u011f\u0131ms\u0131z olarak \u00e7al\u0131\u015f\u0131r<\/li>\n<li><strong>DC1000V Y\u00fcksek Voltaj De\u011feri<\/strong>: Y\u00fcksek verimli mod\u00fcllere sahip yeni nesil solar sistemler i\u00e7in optimize edilmi\u015ftir<\/li>\n<li><strong>\u00dc\u00e7l\u00fc Koruma Sistemleri<\/strong>: \u00dcst\u00fcn g\u00fcvenlik i\u00e7in \u00fc\u00e7 eksiksiz koruma seti (3 anahtar, 3 SPD, 6 sigorta)<\/li>\n<li><strong>\u00c7\u0131k\u0131\u015f Ba\u015f\u0131na 45A<\/strong>: \u00dc\u00e7 \u00e7\u0131k\u0131\u015f\u0131n her biri 45A i\u00e7in derecelendirilmi\u015ftir ve y\u00fcksek g\u00fc\u00e7l\u00fc dizeleri destekler<\/li>\n<li><strong>Bireysel Kontrol<\/strong>: Di\u011ferlerini etkilemeden herhangi bir dizeyi \u00e7al\u0131\u015ft\u0131r\u0131n, bak\u0131m\u0131n\u0131 yap\u0131n veya izole edin<\/li>\n<li><strong>Geli\u015ftirilmi\u015f G\u00fcvenlik<\/strong>: Tam devre izolasyonu, devreler aras\u0131 hatalar\u0131 ortadan kald\u0131r\u0131r ve sorun gidermeyi basitle\u015ftirir<\/li>\n<li><strong>Geni\u015f Kapasiteli Muhafaza<\/strong>: VOAT-39 (296 x 550 x 130mm) \u00fc\u00e7 tam koruma devresini bar\u0131nd\u0131r\u0131r<\/li>\n<li><strong>Sa\u011flam Yap\u0131<\/strong>: IP65 dereceli ABS muhafaza zorlu \u00e7evre ko\u015fullar\u0131na dayan\u0131r<\/li>\n<li><strong>\u00dc\u00e7 Fazl\u0131 Uyumlu<\/strong>: Ayr\u0131 DC giri\u015flerine sahip \u00fc\u00e7 fazl\u0131 invert\u00f6r sistemleri i\u00e7in idealdir<\/li>\n<li><strong>A\u015famal\u0131 \u00c7al\u0131\u015fmaya Haz\u0131r<\/strong>: A\u015famal\u0131 devreye alma i\u00e7in bireysel devreleri etkinle\u015ftirin veya devre d\u0131\u015f\u0131 b\u0131rak\u0131n<\/li>\n<li><strong>Sertifikal\u0131 Kalite<\/strong>: Y\u00fcksek voltajl\u0131 fotovoltaik uygulamalar i\u00e7in EN50539 Tip 2 standartlar\u0131na uygundur<\/li>\n<\/ul>\n<h2>Teknik \u00d6zellikler<\/h2>\n<h3>Genel Veriler<\/h3>\n<table style=\"border-collapse: collapse; width: 100%; margin-bottom: 20px;\" border=\"1\">\n<thead>\n<tr style=\"background-color: #f2f2f2;\">\n<th>Parametre<\/th>\n<th>\u015eartname<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Model<\/td>\n<td>VOPV1000-3\/3<\/td>\n<\/tr>\n<tr>\n<td>Nominal Gerilim<\/td>\n<td>DC1000V<\/td>\n<\/tr>\n<tr>\n<td>Konfig\u00fcrasyon<\/td>\n<td>3 Ba\u011f\u0131ms\u0131z Giri\u015f \/ 3 Ba\u011f\u0131ms\u0131z \u00c7\u0131k\u0131\u015f<\/td>\n<\/tr>\n<tr>\n<td>\u00c7\u0131k\u0131\u015f Ba\u015f\u0131na Maksimum Ak\u0131m<\/td>\n<td>45A<\/td>\n<\/tr>\n<tr>\n<td>Maksimum Dizi Ak\u0131m\u0131<\/td>\n<td>Dizi ba\u015f\u0131na 15A<\/td>\n<\/tr>\n<tr>\n<td>Koruma Derecesi<\/td>\n<td>IP65<\/td>\n<\/tr>\n<tr>\n<td>\u00c7al\u0131\u015fma S\u0131cakl\u0131\u011f\u0131<\/td>\n<td>-25\u00b0C ila +60\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Maksimum Y\u00fckseklik<\/td>\n<td>2000m (standart), istek \u00fczerine &gt;2000m<\/td>\n<\/tr>\n<tr>\n<td>Standart Uyumluluk<\/td>\n<td>EN50539 Tip 2<\/td>\n<\/tr>\n<tr>\n<td>\u0130zolasyon Gerilimi<\/td>\n<td>DC1500V<\/td>\n<\/tr>\n<tr>\n<td>Devre Ba\u011f\u0131ms\u0131zl\u0131\u011f\u0131<\/td>\n<td>\u00dc\u00e7 devre aras\u0131nda tam elektriksel izolasyon<\/td>\n<\/tr>\n<tr>\n<td>\u00d6nerilen Sistem Boyutu<\/td>\n<td>15-25kW (\u00e7oklu invert\u00f6r veya \u00e7oklu MPPT)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Muhafaza \u00d6zellikleri<\/h3>\n<table style=\"border-collapse: collapse; width: 100%; margin-bottom: 20px;\" border=\"1\">\n<thead>\n<tr style=\"background-color: #f2f2f2;\">\n<th>Parametre<\/th>\n<th>De\u011fer<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Model<\/td>\n<td>VOAT-39<\/td>\n<\/tr>\n<tr>\n<td>Malzeme<\/td>\n<td>ABS (Akrilonitril B\u00fctadien Stiren)<\/td>\n<\/tr>\n<tr>\n<td>Koruma Derecesi<\/td>\n<td>IP65<\/td>\n<\/tr>\n<tr>\n<td>Boyutlar (Y x G x D)<\/td>\n<td>296mm x 550mm x 130mm<\/td>\n<\/tr>\n<tr>\n<td>Montaj Tipi<\/td>\n<td>Duvara monte<\/td>\n<\/tr>\n<tr>\n<td>Renk<\/td>\n<td>A\u00e7\u0131k Gri (RAL 7035)<\/td>\n<\/tr>\n<tr>\n<td>Yang\u0131n Derecesi<\/td>\n<td>Kendili\u011finden s\u00f6nen, UL94 V0 alev geciktirici malzeme<\/td>\n<\/tr>\n<tr>\n<td>UV Dayan\u0131m\u0131<\/td>\n<td>D\u0131\u015f mekan uygulamalar\u0131 i\u00e7in UV stabilize<\/td>\n<\/tr>\n<tr>\n<td>Kablo Giri\u015f Noktalar\u0131<\/td>\n<td>\u00c7oklu M16\/M20\/M25 knock-out (3 devre i\u00e7in d\u00fczenlenmi\u015f)<\/td>\n<\/tr>\n<tr>\n<td>A\u011f\u0131rl\u0131k<\/td>\n<td>Yakla\u015f\u0131k 6.5kg (t\u00fcm bile\u015fenlerle)<\/td>\n<\/tr>\n<tr>\n<td>\u0130\u00e7 D\u00fczen<\/td>\n<td>Net ayr\u0131m ve etiketleme ile \u00fc\u00e7 ba\u011f\u0131ms\u0131z devre b\u00f6l\u00fcm\u00fc<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>PV Ay\u0131r\u0131c\u0131 Anahtar\u0131<\/h3>\n<table style=\"border-collapse: collapse; width: 100%; margin-bottom: 20px;\" border=\"1\">\n<thead>\n<tr style=\"background-color: #f2f2f2;\">\n<th>Parametre<\/th>\n<th>\u015eartname<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Model<\/td>\n<td>VOD1-63\/4B<\/td>\n<\/tr>\n<tr>\n<td>Tip<\/td>\n<td>DC Y\u00fck Kesme Anahtar\u0131<\/td>\n<\/tr>\n<tr>\n<td>Miktar<\/td>\n<td>3 adet (devre ba\u015f\u0131na bir adet)<\/td>\n<\/tr>\n<tr>\n<td>Nominal Gerilim<\/td>\n<td>DC1000V<\/td>\n<\/tr>\n<tr>\n<td>Anma Ak\u0131m\u0131<\/td>\n<td>Anahtar ba\u015f\u0131na 45A<\/td>\n<\/tr>\n<tr>\n<td>Direk Say\u0131s\u0131<\/td>\n<td>Anahtar ba\u015f\u0131na 2 kutuplu (pozitif ve negatif)<\/td>\n<\/tr>\n<tr>\n<td>Kesme Kapasitesi<\/td>\n<td>EN50539'a g\u00f6re<\/td>\n<\/tr>\n<tr>\n<td>Operasyon<\/td>\n<td>Net A\u00c7IK\/KAPALI g\u00f6stergesi ile manuel d\u00f6ner \u00e7al\u0131\u015ft\u0131rma<\/td>\n<\/tr>\n<tr>\n<td>Montaj<\/td>\n<td>DIN ray\u0131 uyumlu (35mm)<\/td>\n<\/tr>\n<tr>\n<td>Sap Tipi<\/td>\n<td>Asma kilit \u00f6zellikli k\u0131rm\u0131z\u0131\/ye\u015fil d\u00f6ner sap<\/td>\n<\/tr>\n<tr>\n<td>\u0130leti\u015fim Malzemesi<\/td>\n<td>DC anahtarlamas\u0131 i\u00e7in optimize edilmi\u015f g\u00fcm\u00fc\u015f ala\u015f\u0131m\u0131<\/td>\n<\/tr>\n<tr>\n<td>Ba\u011f\u0131ms\u0131zl\u0131k<\/td>\n<td>Her anahtar yaln\u0131zca kar\u015f\u0131l\u0131k gelen devresini kontrol eder<\/td>\n<\/tr>\n<tr>\n<td>Elektriksel Ya\u015fam<\/td>\n<td>Nominal ak\u0131mda &gt;10.000 i\u015flem<\/td>\n<\/tr>\n<tr>\n<td>Mekanik \u00d6m\u00fcr<\/td>\n<td>&gt;100.000 i\u015flem<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>DC A\u015f\u0131r\u0131 Gerilim Tutucu (SPD)<\/h3>\n<table style=\"border-collapse: collapse; width: 100%; margin-bottom: 20px;\" border=\"1\">\n<thead>\n<tr style=\"background-color: #f2f2f2;\">\n<th>Parametre<\/th>\n<th>\u015eartname<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Model<\/td>\n<td>VO-PV1000<\/td>\n<\/tr>\n<tr>\n<td>Tip<\/td>\n<td>Tip 2 DC A\u015f\u0131r\u0131 Gerilim Koruma Cihaz\u0131<\/td>\n<\/tr>\n<tr>\n<td>Miktar<\/td>\n<td>3 adet (devre ba\u015f\u0131na bir adet)<\/td>\n<\/tr>\n<tr>\n<td>Maksimum S\u00fcrekli \u00c7al\u0131\u015fma Gerilimi (Uc)<\/td>\n<td>DC1000V<\/td>\n<\/tr>\n<tr>\n<td>Nominal De\u015farj Ak\u0131m\u0131 (In)<\/td>\n<td>\u00dcnite ba\u015f\u0131na 20kA (8\/20\u03bcs)<\/td>\n<\/tr>\n<tr>\n<td>Maksimum De\u015farj Ak\u0131m\u0131 (Imax)<\/td>\n<td>\u00dcnite ba\u015f\u0131na 40kA (8\/20\u03bcs)<\/td>\n<\/tr>\n<tr>\n<td>Gerilim Koruma Seviyesi (Up)<\/td>\n<td>\u22643.5kV<\/td>\n<\/tr>\n<tr>\n<td>Direk Say\u0131s\u0131<\/td>\n<td>\u00dcnite ba\u015f\u0131na 2 kutuplu + PE<\/td>\n<\/tr>\n<tr>\n<td>Tepki S\u00fcresi<\/td>\n<td>&lt;25ns<\/td>\n<\/tr>\n<tr>\n<td>Durum G\u00f6stergesi<\/td>\n<td>G\u00f6rsel g\u00f6sterge penceresi (ye\u015fil = OK, k\u0131rm\u0131z\u0131 = de\u011fi\u015ftir)<\/td>\n<\/tr>\n<tr>\n<td>Standart<\/td>\n<td>EN50539 Tip 2, IEC 61643-31<\/td>\n<\/tr>\n<tr>\n<td>Montaj<\/td>\n<td>DIN ray\u0131 uyumlu<\/td>\n<\/tr>\n<tr>\n<td>Ba\u011f\u0131ms\u0131zl\u0131k<\/td>\n<td>Her SPD yaln\u0131zca kar\u015f\u0131l\u0131k gelen devresini korur<\/td>\n<\/tr>\n<tr>\n<td>Takip Ak\u0131m\u0131 S\u00f6n\u00fcm\u00fc<\/td>\n<td>Kendili\u011finden s\u00f6nen tasar\u0131m<\/td>\n<\/tr>\n<tr>\n<td>Termal Ay\u0131r\u0131c\u0131<\/td>\n<td>\u00d6m\u00fcr sonu korumas\u0131 i\u00e7in entegre<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>DC Sigorta Tutucu &amp; Sigorta<\/h3>\n<table style=\"border-collapse: collapse; width: 100%; margin-bottom: 20px;\" border=\"1\">\n<thead>\n<tr style=\"background-color: #f2f2f2;\">\n<th>Parametre<\/th>\n<th>\u015eartname<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Model<\/td>\n<td>VOPV-32<\/td>\n<\/tr>\n<tr>\n<td>Sigorta Tipi<\/td>\n<td>gPV (Fotovoltaik sigorta)<\/td>\n<\/tr>\n<tr>\n<td>Nominal Gerilim<\/td>\n<td>DC1000V<\/td>\n<\/tr>\n<tr>\n<td>Anma Ak\u0131m\u0131<\/td>\n<td>15A<\/td>\n<\/tr>\n<tr>\n<td>Kesme Kapasitesi<\/td>\n<td>30kA @ DC1000V<\/td>\n<\/tr>\n<tr>\n<td>Sigorta Boyutu<\/td>\n<td>10 x 38mm<\/td>\n<\/tr>\n<tr>\n<td>Konfig\u00fcrasyon<\/td>\n<td>Toplam 6 sigorta tutucu (dize ba\u015f\u0131na 2: pozitif ve negatif)<\/td>\n<\/tr>\n<tr>\n<td>Sigorta Ba\u011flant\u0131lar\u0131 Dahil<\/td>\n<td>6 adet (15A DC gPV sigortas\u0131)<\/td>\n<\/tr>\n<tr>\n<td>Koruma \u015eemas\u0131<\/td>\n<td>Her bir \u00fc\u00e7 dizi i\u00e7in ayr\u0131 ayr\u0131 \u00e7ift kutuplu koruma<\/td>\n<\/tr>\n<tr>\n<td>Montaj<\/td>\n<td>DIN ray\u0131 uyumlu<\/td>\n<\/tr>\n<tr>\n<td>Standart<\/td>\n<td>IEC 60269-6<\/td>\n<\/tr>\n<tr>\n<td>G\u00f6sterge<\/td>\n<td>Tutucu ba\u015f\u0131na g\u00f6rsel sigorta durumu g\u00f6stergesi<\/td>\n<\/tr>\n<tr>\n<td>\u0130leti\u015fim Malzemesi<\/td>\n<td>Bak\u0131r, kalay kapl\u0131<\/td>\n<\/tr>\n<tr>\n<td>\u00c7al\u0131\u015fma S\u0131cakl\u0131\u011f\u0131<\/td>\n<td>-40\u00b0C ile +85\u00b0C aras\u0131<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Elektriksel Konfig\u00fcrasyon<\/h2>\n<p>VOPV1000-3\/3 benzersiz bir <strong>\u00fc\u00e7 ba\u011f\u0131ms\u0131z devre mimarisine sahiptir<\/strong> bu, birle\u015ftirme konfig\u00fcrasyonlar\u0131ndan temel olarak farkl\u0131d\u0131r:<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-20933\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/12\/VOPV1000-3_3-Solar-Combiner-Box-Diagram.webp\" alt=\"VOPV1000-3\/3 Solar Combiner Box Diagram\" width=\"1028\" height=\"630\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/12\/VOPV1000-3_3-Solar-Combiner-Box-Diagram.webp 1028w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/12\/VOPV1000-3_3-Solar-Combiner-Box-Diagram-300x184.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/12\/VOPV1000-3_3-Solar-Combiner-Box-Diagram-1024x628.webp 1024w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/12\/VOPV1000-3_3-Solar-Combiner-Box-Diagram-768x471.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/12\/VOPV1000-3_3-Solar-Combiner-Box-Diagram-18x12.webp 18w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/12\/VOPV1000-3_3-Solar-Combiner-Box-Diagram-600x368.webp 600w\" sizes=\"(max-width: 1028px) 100vw, 1028px\" \/><\/p>\n<h3>\u00dc\u00e7 Ba\u011f\u0131ms\u0131z Devre Yolu:<\/h3>\n<h4>Devre 1:<\/h4>\n<ul>\n<li>Dizi 1 Giri\u015fi (pozitif + ve negatif -)<\/li>\n<li>\u00c7ift kutuplu sigorta korumas\u0131 (2 sigorta)<\/li>\n<li>VO-PV1000 a\u015f\u0131r\u0131 gerilim koruma cihaz\u0131<\/li>\n<li>VOD1-63\/4B ay\u0131r\u0131c\u0131 \u015falter<\/li>\n<li>\u00c7\u0131k\u0131\u015f 1 (evirici\/MPPT giri\u015f 1'e ba\u011f\u0131ms\u0131z besleme)<\/li>\n<\/ul>\n<h4>Devre 2:<\/h4>\n<ul>\n<li>Dizi 2 Giri\u015fi (pozitif + ve negatif -)<\/li>\n<li>\u00c7ift kutuplu sigorta korumas\u0131 (2 sigorta)<\/li>\n<li>VO-PV1000 a\u015f\u0131r\u0131 gerilim koruma cihaz\u0131<\/li>\n<li>VOD1-63\/4B ay\u0131r\u0131c\u0131 \u015falter<\/li>\n<li>\u00c7\u0131k\u0131\u015f 2 (evirici\/MPPT giri\u015f 2'ye ba\u011f\u0131ms\u0131z besleme)<\/li>\n<\/ul>\n<h4>Devre 3:<\/h4>\n<ul>\n<li>Dizi 3 Giri\u015fi (pozitif + ve negatif -)<\/li>\n<li>\u00c7ift kutuplu sigorta korumas\u0131 (2 sigorta)<\/li>\n<li>VO-PV1000 a\u015f\u0131r\u0131 gerilim koruma cihaz\u0131<\/li>\n<li>VOD1-63\/4B ay\u0131r\u0131c\u0131 \u015falter<\/li>\n<li>\u00c7\u0131k\u0131\u015f 3 (evirici\/MPPT giri\u015f 3'e ba\u011f\u0131ms\u0131z besleme)<\/li>\n<\/ul>\n<h3>Temel Mimari \u00d6zellikler:<\/h3>\n<h4>Tam \u0130zolasyon:<\/h4>\n<ul>\n<li>\u00dc\u00e7 devre aras\u0131nda elektriksel ba\u011flant\u0131 yok<\/li>\n<li>Her devre ba\u011f\u0131ms\u0131z olarak \u00e7al\u0131\u015f\u0131r<\/li>\n<li>Bir devredeki ar\u0131za di\u011ferlerini etkilemez<\/li>\n<li>Bireysel voltaj ve ak\u0131m \u00f6zellikleri korunur<\/li>\n<\/ul>\n<h4>Ba\u011f\u0131ms\u0131z Koruma:<\/h4>\n<ul>\n<li>Her dizinin \u00f6zel a\u015f\u0131r\u0131 ak\u0131m korumas\u0131 (sigortalar) vard\u0131r<\/li>\n<li>Her devrenin \u00f6zel a\u015f\u0131r\u0131 gerilim korumas\u0131 (SPD) vard\u0131r<\/li>\n<li>Her devrenin \u00f6zel izolasyon anahtar\u0131 vard\u0131r<\/li>\n<li>Her koruma cihaz\u0131 i\u00e7in g\u00f6rsel durum izleme<\/li>\n<\/ul>\n<h4>Ba\u011f\u0131ms\u0131z Kontrol:<\/h4>\n<ul>\n<li>Devre ba\u015f\u0131na ayr\u0131 A\u00c7MA\/KAPAMA kontrol\u00fc<\/li>\n<li>Ba\u011f\u0131ms\u0131z kilitleme\/etiketleme \u00f6zelli\u011fi<\/li>\n<li>Sistem kapat\u0131lmadan se\u00e7ici bak\u0131m<\/li>\n<li>A\u015famal\u0131 devreye alma ve \u00e7al\u0131\u015ft\u0131rma<\/li>\n<\/ul>\n<h4>Terminal Yap\u0131land\u0131rmas\u0131:<\/h4>\n<ul>\n<li>6 giri\u015f terminali (dizi ba\u015f\u0131na 2: +\/-)<\/li>\n<li>6 \u00e7\u0131k\u0131\u015f terminali (devre ba\u015f\u0131na 2: +\/-)<\/li>\n<li>1 ortak PE (Koruyucu Toprak) terminali<\/li>\n<li>T\u00fcm terminaller DC1000V i\u00e7in derecelendirilmi\u015ftir<\/li>\n<li>Giri\u015f terminalleri: 4-6mm\u00b2 kablo kapasitesi<\/li>\n<li>\u00c7\u0131k\u0131\u015f terminalleri: 6-16mm\u00b2 kablo kapasitesi<\/li>\n<\/ul>\n<h2>Malzeme Listesi<\/h2>\n<table style=\"border-collapse: collapse; width: 100%; margin-bottom: 20px;\" border=\"1\">\n<thead>\n<tr style=\"background-color: #f2f2f2;\">\n<th>\u00dcr\u00fcn No.<\/th>\n<th>Bile\u015fen<\/th>\n<th>Model\/Spesifikasyon<\/th>\n<th>Miktar<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>ABS Muhafaza<\/td>\n<td>VOAT-39, 296x550x130mm, IP65<\/td>\n<td>1<\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>DC Ay\u0131r\u0131c\u0131 \u015ealter<\/td>\n<td>VOD1-63\/4B, 2P, 45A, DC1000V<\/td>\n<td>3<\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>DC A\u015f\u0131r\u0131 Gerilim Koruyucu<\/td>\n<td>VO-PV1000, Tip 2, 20kA, DC1000V<\/td>\n<td>3<\/td>\n<\/tr>\n<tr>\n<td>4<\/td>\n<td>DC Sigorta Yuvas\u0131<\/td>\n<td>VOPV-32, 10x38mm, DC1000V<\/td>\n<td>6<\/td>\n<\/tr>\n<tr>\n<td>5<\/td>\n<td>DC Sigorta Ba\u011flant\u0131s\u0131 (gPV)<\/td>\n<td>15A, DC1000V, 10x38mm, 30kA<\/td>\n<td>6<\/td>\n<\/tr>\n<tr>\n<td>6<\/td>\n<td>Giri\u015f Terminal Blo\u011fu<\/td>\n<td>4-6mm\u00b2, K\u0131rm\u0131z\u0131\/Siyah, 1000V de\u011ferinde<\/td>\n<td>6<\/td>\n<\/tr>\n<tr>\n<td>7<\/td>\n<td>\u00c7\u0131k\u0131\u015f Terminal Blo\u011fu<\/td>\n<td>6-16mm\u00b2, K\u0131rm\u0131z\u0131\/Siyah, 1000V nominal<\/td>\n<td>6<\/td>\n<\/tr>\n<tr>\n<td>8<\/td>\n<td>PE Terminal Blo\u011fu<\/td>\n<td>6-16mm\u00b2, Sar\u0131\/Ye\u015fil<\/td>\n<td>1<\/td>\n<\/tr>\n<tr>\n<td>9<\/td>\n<td>DIN Ray<\/td>\n<td>35mm standart, \u00e7inko kapl\u0131<\/td>\n<td>3<\/td>\n<\/tr>\n<tr>\n<td>10<\/td>\n<td>Kablo Rakorlar\u0131<\/td>\n<td>M16\/M20\/M25, IP65 nominal, 1000V<\/td>\n<td>12<\/td>\n<\/tr>\n<tr>\n<td>11<\/td>\n<td>Montaj Braketleri<\/td>\n<td>Paslanmaz \u00e7elik 304<\/td>\n<td>3<\/td>\n<\/tr>\n<tr>\n<td>12<\/td>\n<td>Devre Ay\u0131rma Bariyerleri<\/td>\n<td>\u0130letken olmayan b\u00f6l\u00fcc\u00fcler<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td>13<\/td>\n<td>Devre Etiketleri<\/td>\n<td>Devre 1\/2\/3 tan\u0131mlama etiketleri<\/td>\n<td>1 tak\u0131m<\/td>\n<\/tr>\n<tr>\n<td>14<\/td>\n<td>Uyar\u0131 Etiketleri<\/td>\n<td>DC1000V g\u00fcvenlik etiketleri, \u00e7ok dilli<\/td>\n<td>1 tak\u0131m<\/td>\n<\/tr>\n<tr>\n<td>15<\/td>\n<td>Kurulum K\u0131lavuzu<\/td>\n<td>\u0130ngilizce\/\u00c7ok dilli, 3\/3 konfig\u00fcrasyon k\u0131lavuzu<\/td>\n<td>1<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Uygulamalar<\/h2>\n<p>VOPV1000-3\/3 Solar Birle\u015ftirme Kutusu, tam devre ba\u011f\u0131ms\u0131zl\u0131\u011f\u0131 gerektiren geli\u015fmi\u015f g\u00fcne\u015f enerjisi kurulumlar\u0131 i\u00e7in \u00f6zel olarak tasarlanm\u0131\u015ft\u0131r:<\/p>\n<h3>\u00c7oklu Evirici Sistemleri<\/h3>\n<ul>\n<li>\u00dc\u00e7 ayr\u0131 dizi eviricili sistemler<\/li>\n<li>Da\u011f\u0131t\u0131lm\u0131\u015f evirici mimarileri<\/li>\n<li>Mikro evirici ba\u011flant\u0131 merkezleri<\/li>\n<li>Farkl\u0131 \u00e7at\u0131 b\u00f6l\u00fcmleri i\u00e7in birden fazla k\u00fc\u00e7\u00fck evirici<\/li>\n<li>Bak\u0131m i\u00e7in evirici d\u00fczeyinde izolasyon gerektiren sistemler<\/li>\n<\/ul>\n<h3>\u00c7oklu MPPT Evirici Uygulamalar\u0131<\/h3>\n<ul>\n<li>\u00dc\u00e7 MPPT giri\u015fli eviriciler (her devre ayr\u0131 MPPT'ye)<\/li>\n<li>Farkl\u0131 y\u00f6nelimlerden optimize edilmi\u015f g\u00fc\u00e7 toplama<\/li>\n<li>Dizi ba\u015f\u0131na ba\u011f\u0131ms\u0131z maksimum g\u00fc\u00e7 noktas\u0131 takibi<\/li>\n<li>\u00c7oklu DC giri\u015fli hibrit eviriciler<\/li>\n<li>\u0130zole edilmi\u015f DC giri\u015fleri gerektiren y\u00fcksek performansl\u0131 eviriciler<\/li>\n<\/ul>\n<h3>\u00dc\u00e7 Fazl\u0131 G\u00fcne\u015f Enerjisi Sistemleri<\/h3>\n<ul>\n<li>Faz ba\u015f\u0131na ayr\u0131 DC giri\u015fli \u00fc\u00e7 fazl\u0131 evirici sistemleri<\/li>\n<li>Dengeli \u00fc\u00e7 fazl\u0131 g\u00fc\u00e7 \u00fcretimi<\/li>\n<li>End\u00fcstriyel \u00fc\u00e7 fazl\u0131 uygulamalar<\/li>\n<li>\u015eebekeye ba\u011fl\u0131 \u00fc\u00e7 fazl\u0131 ticari kurulumlar<\/li>\n<li>Faza \u00f6zel g\u00fc\u00e7 da\u011f\u0131t\u0131m gereksinimleri<\/li>\n<\/ul>\n<h3>Karma\u015f\u0131k \u00c7ok Y\u00f6nl\u00fc Diziler<\/h3>\n<ul>\n<li>Do\u011fu-Bat\u0131-G\u00fcney \u00fc\u00e7 y\u00f6nl\u00fc sistemler<\/li>\n<li>Farkl\u0131 \u00f6zelliklere sahip farkl\u0131 \u00e7at\u0131 b\u00f6l\u00fcmleri<\/li>\n<li>Ayr\u0131 optimizasyon gerektiren kar\u0131\u015f\u0131k e\u011fim a\u00e7\u0131lar\u0131<\/li>\n<li>Farkl\u0131 g\u00f6lgelendirme desenlerine sahip diziler<\/li>\n<li>\u00c7e\u015fitli ko\u015fullardan optimum enerji hasad\u0131<\/li>\n<\/ul>\n<h3>B\u00fcy\u00fck Konut ve Ticari Tesisler<\/h3>\n<ul>\n<li>Geli\u015fmi\u015f mimariye sahip premium konut sistemleri (15-25kW)<\/li>\n<li>Maksimum esneklik gerektiren ticari \u00e7at\u0131 dizileri<\/li>\n<li>\u00c7oklu b\u00f6lgelere sahip bina entegre fotovoltaik (BIPV)<\/li>\n<li>Da\u011f\u0131t\u0131lm\u0131\u015f g\u00fcne\u015f enerjisi \u00fcretimine sahip end\u00fcstriyel tesisler<\/li>\n<li>Devre ba\u015f\u0131na ayr\u0131 \u00f6l\u00e7\u00fcmlemeye sahip \u00e7ok kirac\u0131l\u0131 binalar<\/li>\n<\/ul>\n<h3>A\u015famal\u0131 Kurulum ve Geni\u015fleme Projeleri<\/h3>\n<ul>\n<li><strong>A\u015fama 1<\/strong>: Devre 1'i kurun, ba\u011f\u0131ms\u0131z olarak \u00e7al\u0131\u015ft\u0131r\u0131n<\/li>\n<li><strong>A\u015fama 2<\/strong>: Devre 1'i etkilemeden Devre 2'yi ekleyin<\/li>\n<li><strong>A\u015fama 3<\/strong>: Tam sistem kapasitesi i\u00e7in Devre 3 ile tamamlay\u0131n<\/li>\n<li><strong>Esneklik<\/strong>: Her a\u015fama s\u00fcre\u00e7 boyunca ba\u011f\u0131ms\u0131z olarak \u00e7al\u0131\u015f\u0131r<\/li>\n<\/ul>\n<h3>Y\u00fcksek G\u00fcvenilirlik ve G\u00fcvenlik A\u00e7\u0131s\u0131ndan Kritik Uygulamalar<\/h3>\n<ul>\n<li>Maksimum hata izolasyonu gerektiren sistemler<\/li>\n<li>Yedeklilik gereksinimleri olan kritik altyap\u0131<\/li>\n<li>Bireysel devre kontrol\u00fc gerektiren uygulamalar<\/li>\n<li>Kapsaml\u0131 g\u00fcvenlik dok\u00fcmantasyonu gerektiren projeler<\/li>\n<li>S\u0131k\u0131 uyumluluk gereksinimleri olan kurulumlar<\/li>\n<\/ul>\n<h3>\u0130zleme ve Veri Toplama Sistemleri<\/h3>\n<ul>\n<li>String seviyesinde performans izleme<\/li>\n<li>Bireysel devre veri toplama<\/li>\n<li>String ba\u015f\u0131na veri gerektiren geli\u015fmi\u015f analizler<\/li>\n<li>Hata alg\u0131lama ve te\u015fhis sistemleri<\/li>\n<li>Gran\u00fcler kontrole sahip enerji y\u00f6netim sistemleri<\/li>\n<\/ul>\n<h2>3\/3 Ba\u011f\u0131ms\u0131z Yap\u0131land\u0131rman\u0131n Faydalar\u0131<\/h2>\n<h3>Tam Devre Ba\u011f\u0131ms\u0131zl\u0131\u011f\u0131<\/h3>\n<ul>\n<li><strong>Toplam Elektriksel \u0130zolasyon<\/strong>: \u00dc\u00e7 devre aras\u0131nda s\u0131f\u0131r elektriksel ba\u011flant\u0131<\/li>\n<li>Bir devredeki ar\u0131za di\u011ferlerine yay\u0131lamaz<\/li>\n<li>Yedeklilik yoluyla maksimum sistem g\u00fcvenilirli\u011fi<\/li>\n<li>Basitle\u015ftirilmi\u015f ar\u0131za te\u015fhisi ve sorun giderme<\/li>\n<li>\u0130zolasyon yoluyla geli\u015fmi\u015f g\u00fcvenlik<\/li>\n<\/ul>\n<ul>\n<li><strong>Bireysel Devre Kontrol\u00fc<\/strong>: Herhangi bir devreyi ba\u011f\u0131ms\u0131z olarak \u00e7al\u0131\u015ft\u0131r\u0131n<\/li>\n<li>Sistem kapat\u0131lmadan bir devrede bak\u0131m<\/li>\n<li>Devreye alma i\u00e7in se\u00e7ici aktivasyon<\/li>\n<li>Ba\u011f\u0131ms\u0131z test ve do\u011frulama<\/li>\n<li>Esnek \u00e7al\u0131\u015fma modlar\u0131<\/li>\n<\/ul>\n<h3>\u00c7oklu \u0130nverter Sistem Avantajlar\u0131<\/h3>\n<ul>\n<li><strong>\u00c7oklu \u0130nverterler i\u00e7in M\u00fckemmel<\/strong>: \u00dc\u00e7 ayr\u0131 invertere do\u011frudan ba\u011flant\u0131<\/li>\n<li>Da\u011f\u0131t\u0131lm\u0131\u015f inverter mimarileri desteklenir<\/li>\n<li>Devre ba\u015f\u0131na optimum inverter boyutland\u0131rmas\u0131<\/li>\n<li>\u0130nverter seviyesinde yedeklilik<\/li>\n<li>Sistem kapal\u0131 kalmadan bireysel inverter bak\u0131m\u0131<\/li>\n<\/ul>\n<ul>\n<li><strong>\u00c7oklu-MPPT Optimizasyonu<\/strong>: Maksimum verimlilik i\u00e7in her devre ayr\u0131 MPPT giri\u015fine<\/li>\n<li>String y\u00f6nlendirmesi ba\u015f\u0131na ba\u011f\u0131ms\u0131z optimizasyon<\/li>\n<li>Karma\u015f\u0131k g\u00f6lgelendirme senaryolar\u0131nda daha iyi performans<\/li>\n<li>\u00c7e\u015fitli ko\u015fullardan maksimum enerji hasad\u0131<\/li>\n<li>Geli\u015fmi\u015f g\u00fc\u00e7 elektroni\u011fi entegrasyonu<\/li>\n<\/ul>\n<h3>Geli\u015ftirilmi\u015f G\u00fcvenlik ve G\u00fcvenilirlik<\/h3>\n<ul>\n<li><strong>Maksimum Hata \u0130zolasyonu<\/strong>: Bir stringdeki ar\u0131za di\u011ferlerini etkilemez<\/li>\n<li>Bir devre ar\u0131zalan\u0131rsa 67% kapasitesinde \u00e7al\u0131\u015fmaya devam edin<\/li>\n<li>Kademeli ar\u0131za riskini azalt\u0131r<\/li>\n<li>Geli\u015fmi\u015f ark hatas\u0131 s\u0131n\u0131rlamas\u0131<\/li>\n<li>\u0130zole devrelerle basitle\u015ftirilmi\u015f sorun giderme<\/li>\n<\/ul>\n<ul>\n<li><strong>Bireysel Koruma Cihazlar\u0131<\/strong>: \u00dc\u00e7 tam koruma seti, tek ar\u0131za noktalar\u0131n\u0131 ortadan kald\u0131r\u0131r<\/li>\n<li>Devre ba\u015f\u0131na ba\u011f\u0131ms\u0131z a\u015f\u0131r\u0131 gerilim korumas\u0131<\/li>\n<li>Bak\u0131m g\u00fcvenli\u011fi i\u00e7in devre ba\u015f\u0131na \u00f6zel anahtarlama<\/li>\n<li>Bireysel sigortalama, devreler aras\u0131 sorunlar\u0131 \u00f6nler<\/li>\n<li>Yedekli koruma felsefesi<\/li>\n<\/ul>\n<h3>Operasyonel Esneklik<\/h3>\n<ul>\n<li><strong>A\u015famal\u0131 Devreye Alma<\/strong>: Devreye alma s\u0131ras\u0131nda devreleri tek tek etkinle\u015ftirin<\/li>\n<li>Her devreyi ba\u011f\u0131ms\u0131z olarak test edin<\/li>\n<li>Basitle\u015ftirilmi\u015f ba\u015flatma prosed\u00fcrleri<\/li>\n<li>Azalt\u0131lm\u0131\u015f devreye alma riski<\/li>\n<li>Sistematik do\u011frulama s\u00fcreci<\/li>\n<\/ul>\n<ul>\n<li><strong>Se\u00e7ici Bak\u0131m<\/strong>: Di\u011ferleri \u00e7al\u0131\u015f\u0131r durumda kal\u0131rken bir devreye servis verin<\/li>\n<li>Sistem ar\u0131za s\u00fcresini en aza indirin<\/li>\n<li>\u00dcretim kayb\u0131 olmadan planl\u0131 bak\u0131m<\/li>\n<li>Bireysel bile\u015fen de\u011fi\u015fimi<\/li>\n<li>Basitle\u015ftirilmi\u015f kilitleme\/etiketleme prosed\u00fcrleri<\/li>\n<\/ul>\n<ul>\n<li><strong>Kar\u0131\u015f\u0131k Sistem Konfig\u00fcrasyonlar\u0131<\/strong>: Devre ba\u015f\u0131na farkl\u0131 dizi konfig\u00fcrasyonlar\u0131 m\u00fcmk\u00fcnd\u00fcr<\/li>\n<li>Devre ba\u015f\u0131na de\u011fi\u015fen mod\u00fcl t\u00fcrleri veya miktarlar\u0131<\/li>\n<li>Zaman i\u00e7indeki sistem de\u011fi\u015fikliklerine uyum sa\u011flay\u0131n<\/li>\n<li>Gelecekteki modifikasyonlar i\u00e7in esnek<\/li>\n<li>Eski ve yeni bile\u015fenleri ayn\u0131 anda destekleyin<\/li>\n<\/ul>\n<h3>Performans Avantajlar\u0131<\/h3>\n<ul>\n<li><strong>Optimize Edilmi\u015f G\u00fc\u00e7 Elektroni\u011fi<\/strong>: Her devre, kendi \u00f6zel ko\u015fullar\u0131 i\u00e7in optimize edilmi\u015ftir<\/li>\n<li>Ayr\u0131 giri\u015flerle daha iyi MPPT performans\u0131<\/li>\n<li>Dizi uyumsuzlu\u011fundan kaynaklanan kay\u0131plar\u0131 azalt\u0131r<\/li>\n<li>K\u0131smi g\u00f6lgelenmede geli\u015fmi\u015f performans<\/li>\n<li>Farkl\u0131 y\u00f6nelimlerden maksimum enerji verimi<\/li>\n<\/ul>\n<ul>\n<li><strong>Dizi Seviyesi \u0130zleme<\/strong>: Devre ba\u015f\u0131na hassas performans verileri<\/li>\n<li>D\u00fc\u015f\u00fck performans g\u00f6steren dizileri hemen belirleyin<\/li>\n<li>Ayr\u0131nt\u0131l\u0131 enerji \u00fcretim analiti\u011fi<\/li>\n<li>\u00d6ng\u00f6r\u00fcc\u00fc bak\u0131m yetenekleri<\/li>\n<li>Geli\u015fmi\u015f sistem optimizasyonu<\/li>\n<\/ul>\n<h3>3\/1 Konfig\u00fcrasyonuna Kar\u015f\u0131 Maliyet-Fayda Analizi<\/h3>\n<ul>\n<li><strong>Daha Y\u00fcksek \u0130lk Yat\u0131r\u0131m ancak Daha B\u00fcy\u00fck De\u011fer<\/strong>: Payla\u015f\u0131lan bile\u015fenlere kar\u015f\u0131 \u00fc\u00e7 tam koruma seti<\/li>\n<li>Ba\u011f\u0131ms\u0131z devreleri bar\u0131nd\u0131rmak i\u00e7in daha b\u00fcy\u00fck muhafaza<\/li>\n<li>Daha karma\u015f\u0131k kablolama ancak daha fazla esneklik<\/li>\n<li>Daha y\u00fcksek bile\u015fen say\u0131s\u0131 g\u00fcvenilirli\u011fi sa\u011flar<\/li>\n<\/ul>\n<ul>\n<li><strong>Uzun Vadeli Operasyonel Tasarruflar<\/strong>: Azalt\u0131lm\u0131\u015f bak\u0131m ar\u0131za s\u00fcresi (tek seferde bir devreyi koruyun)<\/li>\n<li>Optimizasyon yoluyla daha iyi enerji verimi<\/li>\n<li>Toplam sistem ar\u0131zas\u0131 riski daha d\u00fc\u015f\u00fck<\/li>\n<li>Basitle\u015ftirilmi\u015f sorun giderme, servis maliyetlerini azalt\u0131r<\/li>\n<li>Yedeklilik yoluyla uzat\u0131lm\u0131\u015f sistem \u00f6mr\u00fc<\/li>\n<\/ul>\n<p><strong>\u0130deal Oldu\u011funda:<\/strong><\/p>\n<ul>\n<li>\u00c7oklu MPPT invert\u00f6rler kullan\u0131l\u0131yorsa (kapasitelerini en \u00fcst d\u00fczeye \u00e7\u0131kar\u0131n)<\/li>\n<li>Sistemde birden fazla invert\u00f6r varsa (do\u011frudan ba\u011flant\u0131)<\/li>\n<li>Maksimum g\u00fcvenilirlik gerekiyorsa (kritik uygulamalar)<\/li>\n<li>Karma\u015f\u0131k y\u00f6nelimler (her birini ayr\u0131 ayr\u0131 optimize edin)<\/li>\n<li>A\u015famal\u0131 kurulum planlan\u0131yorsa (zaman i\u00e7inde devreler ekleyin)<\/li>\n<\/ul>\n<h2>Kalite ve Uyumluluk<\/h2>\n<h3>Sertifikalar ve Standartlar:<\/h3>\n<ul>\n<li>EN50539 Tip 2 \u2013 Fotovoltaik (PV) sistemleri \u2013 1000V uygulamalar\u0131 i\u00e7in DC konekt\u00f6rleri<\/li>\n<li>IEC 60269-6 \u2013 Fotovoltaik uygulamalar i\u00e7in al\u00e7ak gerilim sigortalar\u0131 (1000V)<\/li>\n<li>IEC 61643-31 \u2013 Fotovoltaik kurulumlar i\u00e7in a\u015f\u0131r\u0131 gerilim koruma cihazlar\u0131 (1000V)<\/li>\n<li>IEC 60947-3 \u2013 Al\u00e7ak gerilim \u015falt cihazlar\u0131 \u2013 Anahtarlar, ay\u0131r\u0131c\u0131lar (1000V DC)<\/li>\n<li>IP65 \u2013 Giri\u015f Korumas\u0131 (toz ge\u00e7irmez ve su jeti korumal\u0131)<\/li>\n<li>RoHS Uyumlu \u2013 Tehlikeli Maddelerin K\u0131s\u0131tlanmas\u0131<\/li>\n<li>REACH Uyumlu \u2013 AB kimyasallar d\u00fczenlemesi<\/li>\n<li>CE \u0130\u015fareti \u2013 Avrupa uygunlu\u011fu<\/li>\n<\/ul>\n<h3>Kalite G\u00fcvence Testi:<\/h3>\n<ul>\n<li>\u00dc\u00e7 ba\u011f\u0131ms\u0131z devrenin tamam\u0131n\u0131n 100% fabrika testi<\/li>\n<li>Y\u00fcksek voltaj dayan\u0131m testi (devre ba\u015f\u0131na 1 dakika boyunca DC1500V)<\/li>\n<li>Yal\u0131t\u0131m direnci do\u011frulamas\u0131 (&gt;devre ba\u015f\u0131na DC1000V'ta 200M\u03a9)<\/li>\n<li>Devre izolasyon testi (devreler aras\u0131nda &gt;200M\u03a9)<\/li>\n<li>Y\u00fcksek s\u0131cakl\u0131k ya\u015fland\u0131rma testleri (70\u00b0C'de 96 saat)<\/li>\n<li>Termal d\u00f6ng\u00fc testleri (-40\u00b0C ila +85\u00b0C, 100 d\u00f6ng\u00fc)<\/li>\n<li>Mekanik stres testi (IEC standartlar\u0131na g\u00f6re titre\u015fim ve darbe)<\/li>\n<li>T\u00fcm terminallerde temas direnci \u00f6l\u00e7\u00fcm\u00fc (&lt;30\u03bc\u03a9)<\/li>\n<li>\u00dc\u00e7 a\u015f\u0131r\u0131 gerilim koruma cihaz\u0131n\u0131n tamam\u0131 IEC 61643-31'e g\u00f6re test edilmi\u015ftir<\/li>\n<li>Muhafaza malzemeleri i\u00e7in UV ya\u015fland\u0131rma testi (1000 saat)<\/li>\n<li>\u00dc\u00e7 devrenin tamam\u0131 i\u00e7in ba\u011f\u0131ms\u0131z \u00e7al\u0131\u015fma do\u011frulamas\u0131<\/li>\n<\/ul>\n<h3>\u00dcretimde M\u00fckemmellik:<\/h3>\n<ul>\n<li>ISO 9001:2015 sertifikal\u0131 \u00fcretim tesisi<\/li>\n<li>ISO 14001:2015 \u00e7evre y\u00f6netim sistemi<\/li>\n<li>\u00c7ok devreli montajlar i\u00e7in s\u0131k\u0131 kalite kontrol prosed\u00fcrleri<\/li>\n<li>Sertifikal\u0131 tedarik\u00e7ilerden (UL, T\u00dcV listeli) birinci s\u0131n\u0131f bile\u015fen se\u00e7imi<\/li>\n<li>Ba\u011f\u0131ms\u0131z devre mimarisi i\u00e7in \u00f6zel montaj s\u00fcreci<\/li>\n<li>T\u00fcm elektrik ba\u011flant\u0131lar\u0131n\u0131n ve izolasyon bariyerlerinin manuel olarak incelenmesi<\/li>\n<li>Devre ba\u015f\u0131na kapsaml\u0131 son inceleme ve fonksiyonel test<\/li>\n<li>T\u00fcm bile\u015fenler ve montajlar i\u00e7in eksiksiz izlenebilirlik sistemi<\/li>\n<li>Saha performans\u0131 verilerine dayal\u0131 s\u00fcrekli iyile\u015ftirme programlar\u0131<\/li>\n<\/ul>\n<h2>Kurulum ve Bak\u0131m<\/h2>\n<h3>Kurulum Y\u00f6nergeleri<\/h3>\n<h4>\u00c7ok Devreli Kurulum i\u00e7in Saha Se\u00e7imi:<\/h4>\n<ul>\n<li>Bak\u0131m i\u00e7in kolay eri\u015filebilir, iyi havaland\u0131r\u0131lan bir yere monte edin.<\/li>\n<li>Do\u011frudan g\u00fcne\u015f \u0131\u015f\u0131\u011f\u0131ndan, ya\u011fmurdan ve su birikmesinden koruyun<\/li>\n<li>Havaland\u0131rma ve eri\u015fim i\u00e7in her tarafta minimum 200 mm bo\u015fluk b\u0131rak\u0131n.<\/li>\n<li>\u00dc\u00e7 farkl\u0131 dizi konumundan kablo giri\u015f yollar\u0131n\u0131 g\u00f6z \u00f6n\u00fcnde bulundurun<\/li>\n<li>\u00dc\u00e7 SPD g\u00f6stergesinin tamam\u0131n\u0131n kolayca g\u00f6rsel olarak incelenebilece\u011fi \u015fekilde konumland\u0131r\u0131n.<\/li>\n<li>Gelecekteki bireysel devre servis eri\u015fimi i\u00e7in yeterli alan oldu\u011fundan emin olun.<\/li>\n<\/ul>\n<h4>Montaj Prosed\u00fcr\u00fc:<\/h4>\n<ul>\n<li>Muhafaza a\u011f\u0131rl\u0131\u011f\u0131na (6,5 kg + kablolar) uygun, derecelendirilmi\u015f montaj donan\u0131m\u0131 kullan\u0131n.<\/li>\n<li>Su terazisi kullanarak d\u00fcz kurulum sa\u011flay\u0131n (daha b\u00fcy\u00fck muhafazalar i\u00e7in kritik).<\/li>\n<li>Muhafazan\u0131n g\u00fcvenli bir \u015fekilde sabitlendi\u011fini do\u011frulay\u0131n (boyut nedeniyle minimum 6 sabitleme noktas\u0131).<\/li>\n<li>Kurulumdan sonra IP65 koruma derecesini koruyun<\/li>\n<li>A\u011f\u0131rl\u0131k nedeniyle montaj y\u00fczeyindeki y\u00fck da\u011f\u0131l\u0131m\u0131n\u0131 g\u00f6z \u00f6n\u00fcnde bulundurun.<\/li>\n<\/ul>\n<h4>Devre Ba\u011flant\u0131 S\u0131ras\u0131:<\/h4>\n<ul>\n<li>Ba\u011flant\u0131dan \u00f6nce \u00fc\u00e7 devreyi de a\u00e7\u0131k\u00e7a etiketleyin (Devre 1, 2, 3).<\/li>\n<li>Sistematik kurulum i\u00e7in devreleri say\u0131sal s\u0131rayla ba\u011flay\u0131n.<\/li>\n<li><strong>Kritik<\/strong>Kablolama s\u0131ras\u0131nda devreler aras\u0131nda tam ayr\u0131m sa\u011flay\u0131n.<\/li>\n<li>Sonland\u0131rmadan \u00f6nce her devre i\u00e7in do\u011fru polariteyi do\u011frulay\u0131n.<\/li>\n<li>Uygun s\u0131cakl\u0131k derecesine sahip DC1000V i\u00e7in derecelendirilmi\u015f kablolar kullan\u0131n<\/li>\n<li>Giri\u015f kablolar\u0131: 4-6mm\u00b2 (dizi ba\u015f\u0131na maksimum 15A).<\/li>\n<li>\u00c7\u0131k\u0131\u015f kablolar\u0131: 6-16mm\u00b2 (45A kapasiteyi kar\u015f\u0131lamak i\u00e7in).<\/li>\n<\/ul>\n<h4>Ba\u011f\u0131ms\u0131z Devre Kablolamas\u0131:<\/h4>\n<ul>\n<li>Kar\u0131\u015f\u0131kl\u0131\u011f\u0131 \u00f6nlemek i\u00e7in Devre 1, 2 ve 3 kablolar\u0131n\u0131 ayr\u0131 ayr\u0131 y\u00f6nlendirin.<\/li>\n<li>Her devre i\u00e7inde tutarl\u0131 renk kodlamas\u0131 kullan\u0131n (K\u0131rm\u0131z\u0131 +, Siyah -).<\/li>\n<li>M\u00fcmk\u00fcn oldu\u011funca devre kablolar\u0131 aras\u0131nda fiziksel ayr\u0131m sa\u011flay\u0131n.<\/li>\n<li>T\u00fcm kablolar\u0131 devre numaras\u0131yla a\u00e7\u0131k\u00e7a etiketleyin.<\/li>\n<li>T\u00fcm terminallere uygun tork uygulay\u0131n (belirtildi\u011fi gibi 1.2-1.5 Nm)<\/li>\n<li>Uygun rakorlarla uygun kablo giri\u015f yal\u0131t\u0131m\u0131n\u0131 sa\u011flay\u0131n<\/li>\n<\/ul>\n<h4>Devreye Alma \u00d6ncesi Kontroller (Devre Ba\u015f\u0131na):<\/h4>\n<ul>\n<li>Her devrede yal\u0131t\u0131m direnci testi yap\u0131n (minimum 200M\u03a9 @ DC1000V).<\/li>\n<li>Devreler aras\u0131ndaki yal\u0131t\u0131m\u0131 do\u011frulay\u0131n (herhangi iki devre aras\u0131nda minimum 200M\u03a9).<\/li>\n<li>PE ba\u011flant\u0131s\u0131n\u0131n s\u00fcreklili\u011fini do\u011frulay\u0131n (t\u00fcm devreler i\u00e7in ortak).<\/li>\n<li>Her devredeki t\u00fcm mekanik ba\u011flant\u0131lar\u0131n s\u0131k\u0131l\u0131\u011f\u0131n\u0131 kontrol edin.<\/li>\n<li>\u00dc\u00e7 SPD g\u00f6stergesinin de ye\u015fil (\u00e7al\u0131\u015fma durumu) g\u00f6sterdi\u011fini do\u011frulay\u0131n.<\/li>\n<li>Her bir anahtar ay\u0131r\u0131c\u0131n\u0131n \u00e7al\u0131\u015fmas\u0131n\u0131 y\u00fcks\u00fcz durumda ayr\u0131 ayr\u0131 test edin.<\/li>\n<li>T\u00fcm kablo rakorlar\u0131n\u0131n d\u00fczg\u00fcn \u015fekilde yal\u0131t\u0131ld\u0131\u011f\u0131n\u0131 do\u011frulay\u0131n<\/li>\n<li>Her dizinin a\u00e7\u0131k devre voltaj\u0131n\u0131 ba\u011f\u0131ms\u0131z olarak \u00f6l\u00e7\u00fcn.<\/li>\n<li><strong>Kritik<\/strong>Devreler aras\u0131nda elektriksel ba\u011flant\u0131 olmad\u0131\u011f\u0131ndan emin olun.<\/li>\n<\/ul>\n<h4>A\u015famal\u0131 Devreye Alma Prosed\u00fcr\u00fc:<\/h4>\n<ol>\n<li>\u00d6nce Devre 1'i devreye al\u0131n, \u00e7al\u0131\u015fmas\u0131n\u0131 do\u011frulay\u0131n.<\/li>\n<li>Devre 2'yi devreye al\u0131n, Devre 1'in etkilenmedi\u011finden emin olun.<\/li>\n<li>Devre 3'\u00fc devreye al\u0131n, \u00fc\u00e7\u00fcn\u00fcn de ba\u011f\u0131ms\u0131z olarak \u00e7al\u0131\u015ft\u0131\u011f\u0131n\u0131 do\u011frulay\u0131n.<\/li>\n<li>\u0130zolasyonu do\u011frulay\u0131n: di\u011ferleri \u00e7al\u0131\u015f\u0131rken her devreyi ayr\u0131 ayr\u0131 ay\u0131r\u0131n.<\/li>\n<\/ol>\n<h3>G\u00fcvenlik \u00d6nlemleri<\/h3>\n<h4>\u00c7ok Devreli G\u00fcvenlik Hususlar\u0131:<\/h4>\n<ul>\n<li><strong>Kritik<\/strong>Bir devre ba\u011flant\u0131s\u0131 kesilmi\u015f olsa bile, di\u011fer devreler enerjili kal\u0131r.<\/li>\n<li>\u00dc\u00c7 devrenin TAMAMI do\u011frulanana kadar t\u00fcm sistemin enerjisiz oldu\u011funu asla varsaymay\u0131n.<\/li>\n<li>\u00dc\u00e7 devrede de ba\u011f\u0131ms\u0131z olarak \u00e7ok noktal\u0131 voltaj testi kullan\u0131n.<\/li>\n<li>T\u00fcm devrelerde \u00e7al\u0131\u015f\u0131l\u0131yorsa \u00dc\u00c7 AYRI K\u0130L\u0130T ile kilitleme\/etiketleme prosed\u00fcrlerini uygulay\u0131n.<\/li>\n<\/ul>\n<h4>DC1000V \u00c7ok Devreli G\u00fcvenlik:<\/h4>\n<ul>\n<li>Yaln\u0131zca kalifiye personel \u2013 \u00f6zel \u00e7ok devreli e\u011fitim gereklidir.<\/li>\n<li>Her zaman uygun KKD kullan\u0131n: yal\u0131t\u0131ml\u0131 eldivenler (S\u0131n\u0131f 2), g\u00fcvenlik g\u00f6zl\u00fckleri, ark korumal\u0131 giysiler<\/li>\n<li>Yaln\u0131zca CAT III 1000V dereceli test ekipman\u0131 kullan\u0131n<\/li>\n<li>Ba\u011flant\u0131 kesildikten sonra kablolarda kapasitif y\u00fck kalabilece\u011fini unutmay\u0131n.<\/li>\n<\/ul>\n<h4>Operasyonel G\u00fcvenlik:<\/h4>\n<ul>\n<li>O devrenin bile\u015fenlerine eri\u015fmeden \u00f6nce her zaman ilgili anahtar ay\u0131r\u0131c\u0131y\u0131 a\u00e7\u0131n.<\/li>\n<li>Muhafazay\u0131 a\u00e7madan \u00f6nce ba\u011flant\u0131 kesildikten sonra minimum 5 dakika bekleyin<\/li>\n<li>\u0130lgili devrede voltaj olmad\u0131\u011f\u0131n\u0131 do\u011frulamak i\u00e7in voltaj dedekt\u00f6r\u00fc kullan\u0131n.<\/li>\n<li>Biti\u015fik devrelerin izole kald\u0131\u011f\u0131ndan emin olmak i\u00e7in test edin.<\/li>\n<li>Nominal voltaj\u0131 (DC1000V) ve ak\u0131m \u00f6zelliklerini asla a\u015fmay\u0131n.<\/li>\n<li>Anahtar ay\u0131r\u0131c\u0131lar\u0131 y\u00fck alt\u0131nda \u00e7al\u0131\u015ft\u0131rmay\u0131n.<\/li>\n<li>Hangi devreye servis verildi\u011finin a\u00e7\u0131k bir \u015fekilde tan\u0131mlanmas\u0131n\u0131 sa\u011flay\u0131n.<\/li>\n<\/ul>\n<h3>Bak\u0131m \u00d6nerileri<\/h3>\n<h4>D\u00fczenli Denetim (Her 6 Ayda Bir):<\/h4>\n<ul>\n<li>Hasar veya a\u015f\u0131r\u0131 \u0131s\u0131nma belirtileri i\u00e7in \u00fc\u00e7 devrenin de g\u00f6rsel olarak incelenmesi.<\/li>\n<li>\u00dc\u00e7 SPD g\u00f6stergesini de kontrol edin (ye\u015fil = TAMAM, k\u0131rm\u0131z\u0131 = hemen de\u011fi\u015ftirin).<\/li>\n<li>Muhafazay\u0131 \u00e7atlaklar, hasar veya bozulmu\u015f contalar a\u00e7\u0131s\u0131ndan inceleyin<\/li>\n<li>Kablo rakorlar\u0131n\u0131n t\u00fcm devrelerde uygun s\u0131zd\u0131rmazl\u0131k b\u00fct\u00fcnl\u00fc\u011f\u00fcn\u00fc korudu\u011funu do\u011frulay\u0131n.<\/li>\n<li>Herhangi bir nem giri\u015fi belirtisi olup olmad\u0131\u011f\u0131n\u0131 kontrol edin<\/li>\n<li>Her devrenin sigorta durumunu g\u00f6rsel olarak inceleyin.<\/li>\n<li>Devre ay\u0131rma bariyerlerinin sa\u011flam kald\u0131\u011f\u0131n\u0131 do\u011frulay\u0131n.<\/li>\n<\/ul>\n<h4>Y\u0131ll\u0131k Bak\u0131m (Devre Ba\u015f\u0131na):<\/h4>\n<ul>\n<li>Her devredeki t\u00fcm ba\u011flant\u0131lar\u0131n s\u0131k\u0131 kald\u0131\u011f\u0131n\u0131 do\u011frulay\u0131n (yeniden torklay\u0131n: 1,2-1,5 Nm).<\/li>\n<li>Her bir anahtar ay\u0131r\u0131c\u0131n\u0131n \u00e7al\u0131\u015fmas\u0131n\u0131 y\u00fcks\u00fcz durumda ayr\u0131 ayr\u0131 test edin.<\/li>\n<li>Her devrede yal\u0131t\u0131m direnci testi yap\u0131n (200M\u03a9'dan b\u00fcy\u00fck olmal\u0131d\u0131r).<\/li>\n<li>Devreler aras\u0131ndaki yal\u0131t\u0131m\u0131 test edin (herhangi iki \u00e7ift aras\u0131nda 200M\u03a9'dan b\u00fcy\u00fck olmal\u0131d\u0131r).<\/li>\n<li>Muhafaza d\u0131\u015f\u0131n\u0131 nemli bir bezle temizleyin<\/li>\n<li>Her devredeki i\u00e7 bile\u015fenleri ya\u015flanma belirtileri a\u00e7\u0131s\u0131ndan inceleyin.<\/li>\n<li>Her devredeki dizi voltaj\u0131n\u0131 ba\u011f\u0131ms\u0131z olarak do\u011frulay\u0131n.<\/li>\n<\/ul>\n<h4>Bile\u015fen De\u011fi\u015fimi (Devre Ba\u015f\u0131na):<\/h4>\n<ul>\n<li>Sigortalar\u0131 yaln\u0131zca ayn\u0131 \u00f6zelliklere sahip olanlarla de\u011fi\u015ftirin (15A gPV, DC1000V, 10x38mm, 30kA)<\/li>\n<li>Ayn\u0131 devre i\u00e7in sigortalar\u0131 her zaman \u00e7iftler halinde (pozitif ve negatif) de\u011fi\u015ftirin.<\/li>\n<li>SPD de\u011fi\u015fimi: yaln\u0131zca VO-PV1000 veya e\u015fde\u011fer onayl\u0131 modeli kullan\u0131n<\/li>\n<li>SPD de\u011fi\u015ftirilirken, yaln\u0131zca o devrenin enerjisinin kesilmesi gerekir.<\/li>\n<li>Her devre i\u00e7in ayr\u0131nt\u0131l\u0131 bir bak\u0131m g\u00fcnl\u00fc\u011f\u00fc tutun.<\/li>\n<li>Trend analizi i\u00e7in devre ba\u015f\u0131na bile\u015fen de\u011fi\u015fimlerini kaydedin.<\/li>\n<\/ul>\n<h3>Ba\u011f\u0131ms\u0131z Devre Sorun Giderme<\/h3>\n<table style=\"border-collapse: collapse; width: 100%; margin-bottom: 20px;\" border=\"1\">\n<thead>\n<tr style=\"background-color: #f2f2f2;\">\n<th>Belirti<\/th>\n<th>Olas\u0131 Sebep<\/th>\n<th>\u00c7\u00f6z\u00fcm<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Devre 1'de \u00e7\u0131k\u0131\u015f yok, Devre 2&amp;3 tamam<\/td>\n<td>Devre 1 sigortas\u0131 atm\u0131\u015f<\/td>\n<td>Sadece Devre 1 sigortalar\u0131n\u0131 kontrol edin\/de\u011fi\u015ftirin, di\u011ferleri etkilenmez<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Devre 1 anahtar\u0131 KAPALI<\/td>\n<td>Devre 1 anahtar\u0131n\u0131 A\u00c7IK konuma getirin<\/td>\n<\/tr>\n<tr>\n<td>\u00dc\u00e7 devrede de \u00e7\u0131k\u0131\u015f yok<\/td>\n<td>Yukar\u0131 ak\u0131\u015fta ortak sorun<\/td>\n<td>Dizi seviyesi ba\u011flant\u0131lar\u0131n\u0131 kontrol edin<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>\u00dc\u00e7 anahtar da KAPALI<\/td>\n<td>T\u00fcm anahtarlar\u0131n A\u00c7IK konumda oldu\u011funu do\u011frulay\u0131n<\/td>\n<\/tr>\n<tr>\n<td>Bir devre a\u015f\u0131r\u0131 \u0131s\u0131n\u0131yor<\/td>\n<td>O devrede gev\u015fek ba\u011flant\u0131<\/td>\n<td>Sadece etkilenen devredeki terminalleri yeniden s\u0131k\u0131n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>K\u00fc\u00e7\u00fck boyutlu kablo<\/td>\n<td>O devre i\u00e7in kabloyu do\u011frulay\u0131n ve y\u00fckseltin<\/td>\n<\/tr>\n<tr>\n<td>Bir SPD g\u00f6stergesi k\u0131rm\u0131z\u0131<\/td>\n<td>O devrenin SPD'si kullan\u0131m \u00f6mr\u00fcn\u00fcn sonunda<\/td>\n<td>Etkilenen devredeki SPD'yi de\u011fi\u015ftirin, di\u011ferleri \u00e7al\u0131\u015fmaya devam eder<\/td>\n<\/tr>\n<tr>\n<td>Devreler aras\u0131nda dengesiz \u00e7\u0131k\u0131\u015f<\/td>\n<td>Farkl\u0131 dizi yap\u0131land\u0131rmalar\u0131<\/td>\n<td>Her bir dizi tasar\u0131m\u0131n\u0131 ba\u011f\u0131ms\u0131z olarak do\u011frulay\u0131n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Bir dizide mod\u00fcl bozulmas\u0131<\/td>\n<td>Belirli devrenin performans\u0131n\u0131 ara\u015ft\u0131r\u0131n<\/td>\n<\/tr>\n<tr>\n<td>S\u0131k sigorta ar\u0131zas\u0131 (bir devre)<\/td>\n<td>O belirli dizide k\u0131sa devre<\/td>\n<td>Sadece o devre i\u00e7in diziyi inceleyin<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>A\u015f\u0131r\u0131 ak\u0131m durumu<\/td>\n<td>O devrenin dizi tasar\u0131m\u0131n\u0131n &lt;15A oldu\u011funu do\u011frulay\u0131n<\/td>\n<\/tr>\n<tr>\n<td>\u0130ki devre normal, biri aral\u0131kl\u0131<\/td>\n<td>Aral\u0131kl\u0131 devrede ar\u0131zal\u0131 bile\u015fen<\/td>\n<td>O devreyi ba\u011f\u0131ms\u0131z olarak izole edin ve te\u015fhis edin<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Teknik Kar\u015f\u0131la\u015ft\u0131rma: VOPV1000-3\/3 - VOPV1000-3\/1<\/h2>\n<table style=\"border-collapse: collapse; width: 100%; margin-bottom: 20px;\" border=\"1\">\n<thead>\n<tr style=\"background-color: #f2f2f2;\">\n<th>\u00d6zellik<\/th>\n<th>VOPV1000-3\/3<\/th>\n<th>VOPV1000-3\/1<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Mimari<\/td>\n<td>3 Ba\u011f\u0131ms\u0131z Devre<\/td>\n<td>3 Giri\u015f 1 \u00c7\u0131k\u0131\u015fta Birle\u015ftirilmi\u015f<\/td>\n<\/tr>\n<tr>\n<td>String Giri\u015fleri<\/td>\n<td>3<\/td>\n<td>3<\/td>\n<\/tr>\n<tr>\n<td>\u00c7\u0131k\u0131\u015flar<\/td>\n<td>3 Ba\u011f\u0131ms\u0131z<\/td>\n<td>1 Birle\u015ftirilmi\u015f<\/td>\n<\/tr>\n<tr>\n<td>Devre \u0130zolasyonu<\/td>\n<td>Tam (ba\u011flant\u0131 yok)<\/td>\n<td>Birle\u015ftirilmi\u015f (paralel ba\u011flant\u0131)<\/td>\n<\/tr>\n<tr>\n<td>Muhafaza Boyutu<\/td>\n<td>296x550x130mm (VOAT-39)<\/td>\n<td>296x230x120mm (VOAT-13)<\/td>\n<\/tr>\n<tr>\n<td>Anahtar Ay\u0131r\u0131c\u0131lar<\/td>\n<td>3 adet (devre ba\u015f\u0131na bir adet)<\/td>\n<td>1 adet (birle\u015ftirmeden sonra)<\/td>\n<\/tr>\n<tr>\n<td>SPD \u00dcniteleri<\/td>\n<td>3 adet (devre ba\u015f\u0131na bir adet)<\/td>\n<td>1 adet (birle\u015ftirmeden sonra)<\/td>\n<\/tr>\n<tr>\n<td>Sigorta Yuvalar\u0131<\/td>\n<td>6 (dizi ba\u015f\u0131na 2)<\/td>\n<td>6 (dizi ba\u015f\u0131na 2)<\/td>\n<\/tr>\n<tr>\n<td>A\u011f\u0131rl\u0131k<\/td>\n<td>~6.5kg<\/td>\n<td>~3.5kg<\/td>\n<\/tr>\n<tr>\n<td>\u0130deal Uygulama<\/td>\n<td>\u00c7oklu invert\u00f6r, \u00e7oklu MPPT<\/td>\n<td>Tek invert\u00f6r, birle\u015ftirilmi\u015f besleme<\/td>\n<\/tr>\n<tr>\n<td>Devre Kontrol\u00fc<\/td>\n<td>Devre ba\u015f\u0131na ayr\u0131 ayr\u0131<\/td>\n<td>T\u00fcm devreler birlikte<\/td>\n<\/tr>\n<tr>\n<td>Ar\u0131za \u0130zolasyonu<\/td>\n<td>Tam (bir devre ar\u0131zalan\u0131r, di\u011ferleri tamam)<\/td>\n<td>K\u0131smi (ar\u0131za birle\u015ftirilmi\u015f \u00e7\u0131k\u0131\u015f\u0131 etkileyebilir)<\/td>\n<\/tr>\n<tr>\n<td>Bak\u0131m Durdurma S\u00fcresi<\/td>\n<td>Minimum (birine servis yap\u0131n, di\u011ferleri \u00e7al\u0131\u015f\u0131r)<\/td>\n<td>Tam sistem (hepsini ay\u0131rman\u0131z gerekir)<\/td>\n<\/tr>\n<tr>\n<td>\u00c7oklu \u0130nvert\u00f6r Deste\u011fi<\/td>\n<td>M\u00fckemmel (do\u011frudan ba\u011flant\u0131)<\/td>\n<td>Uygulanamaz<\/td>\n<\/tr>\n<tr>\n<td>\u00c7oklu MPPT Deste\u011fi<\/td>\n<td>M\u00fckemmel (devre ba\u015f\u0131na ayr\u0131 MPPT)<\/td>\n<td>S\u0131n\u0131rl\u0131 (birle\u015ftirilmi\u015f giri\u015f)<\/td>\n<\/tr>\n<tr>\n<td>Sistem Boyutu<\/td>\n<td>15-25kW<\/td>\n<td>10-15kW<\/td>\n<\/tr>\n<tr>\n<td>Maliyet<\/td>\n<td>Daha Y\u00fcksek (\u00fc\u00e7l\u00fc koruma)<\/td>\n<td>Daha D\u00fc\u015f\u00fck (payla\u015f\u0131ml\u0131 koruma)<\/td>\n<\/tr>\n<tr>\n<td>Esneklik<\/td>\n<td>Maksimum<\/td>\n<td>Orta d\u00fczeyde<\/td>\n<\/tr>\n<tr>\n<td>\u0130\u00e7in En \u0130yisi<\/td>\n<td>Karma\u015f\u0131k sistemler, maksimum g\u00fcvenilirlik<\/td>\n<td>Basit sistemler, maliyet optimizasyonu<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Neden VIOX VOPV1000-3\/3'\u00fc Se\u00e7melisiniz?<\/h2>\n<ul>\n<li><strong>E\u015fsiz Devre Ba\u011f\u0131ms\u0131zl\u0131\u011f\u0131<\/strong>: \u00dc\u00e7 tamamen izole devre, devreler aras\u0131 giri\u015fimi ortadan kald\u0131r\u0131r, sistem g\u00fcvenilirli\u011fini en \u00fcst d\u00fczeye \u00e7\u0131kar\u0131r ve bir devrede sorun olu\u015fsa bile \u00e7al\u0131\u015fmaya olanak tan\u0131r.<\/li>\n<li><strong>\u00c7oklu \u0130nverter Sistem M\u00fckemmelli\u011fi<\/strong>: \u00dc\u00e7 ayr\u0131 string invertere do\u011frudan ba\u011flant\u0131, da\u011f\u0131t\u0131lm\u0131\u015f mimariler ve geli\u015fmi\u015f \u00e7oklu MPPT sistemleri i\u00e7in idealdir.<\/li>\n<li><strong>\u00dcst\u00fcn G\u00fcvenlik Mimarisi<\/strong>: \u00dc\u00e7l\u00fc koruma sistemleri tek ar\u0131za noktalar\u0131n\u0131 ortadan kald\u0131r\u0131r, daha g\u00fcvenli bak\u0131m ve basitle\u015ftirilmi\u015f kilitleme\/etiketleme i\u00e7in bireysel devre kontrol\u00fc sa\u011flar.<\/li>\n<li><strong>Maksimum Operasyonel Esneklik<\/strong>: A\u015famal\u0131 devreye almay\u0131, se\u00e7ici bak\u0131m\u0131 ve de\u011fi\u015fen sistem gereksinimlerine uyum sa\u011flamak i\u00e7in karma konfig\u00fcrasyonlar\u0131 destekler.<\/li>\n<li><strong>Profesyonel M\u00fchendislik<\/strong>: Optimize edilmi\u015f i\u00e7 d\u00fczenlemeye, birinci s\u0131n\u0131f DC1000V bile\u015fenlerine ve geli\u015fmi\u015f yal\u0131t\u0131m koordinasyonuna sahip geni\u015f VOAT-39 muhafazas\u0131.<\/li>\n<li><strong>Geli\u015fmi\u015f Sistem Yetenekleri<\/strong>: String seviyesi izlemeyi, ak\u0131ll\u0131 g\u00fcne\u015f enerjisi kurulumlar\u0131n\u0131 ve geli\u015fmi\u015f enerji y\u00f6netim sistemlerini destekler.<\/li>\n<li><strong>Uzun Vadeli De\u011fer<\/strong>: Daha y\u00fcksek g\u00fcvenilirlik, toplam sahip olma maliyetini d\u00fc\u015f\u00fcr\u00fcr, bak\u0131m duru\u015f s\u00fcresini en aza indirir ve yedeklilik yoluyla sistem \u00f6mr\u00fcn\u00fc uzat\u0131r.<\/li>\n<\/ul>\n<h2>\u0130leti\u015fime Ge\u00e7in<\/h2>\n<p>VOPV1000-3\/3 Solar Birle\u015ftirme Kutusu ile nihai \u00e7oklu devre \u00e7\u00f6z\u00fcm\u00fcn\u00fc uygulamaya haz\u0131r m\u0131s\u0131n\u0131z? A\u015fa\u011f\u0131dakiler i\u00e7in bug\u00fcn VIOX Electric ile ileti\u015fime ge\u00e7in:<\/p>\n<ul>\n<li>Ayr\u0131nt\u0131l\u0131 teknik \u00f6zellikler ve CAD \u00e7izimleri<\/li>\n<li>\u00c7oklu inverter ve \u00e7oklu MPPT sistem tasar\u0131m dan\u0131\u015fmanl\u0131\u011f\u0131<\/li>\n<li>Ba\u011f\u0131ms\u0131z devre yap\u0131land\u0131rma optimizasyonu<\/li>\n<li>Rekabet\u00e7i fiyatland\u0131rma ve MOQ (Minimum Sipari\u015f Miktar\u0131) bilgileri<\/li>\n<li>Belirli proje gereksinimleri i\u00e7in \u00f6zel yap\u0131land\u0131rma se\u00e7enekleri<\/li>\n<li>Karma\u015f\u0131k \u00e7oklu devre kurulumlar\u0131 hakk\u0131nda teknik rehberlik<\/li>\n<li>Test ve de\u011ferlendirme i\u00e7in numune sipari\u015fleri<\/li>\n<li>Toplu sipari\u015fler i\u00e7in hacim indirimli fiyat teklifleri<\/li>\n<li>Teslimat zaman \u00e7izelgesi ve uluslararas\u0131 lojistik deste\u011fi<\/li>\n<li>3\/3 ba\u011f\u0131ms\u0131z yap\u0131land\u0131rma i\u00e7in \u00f6zel kurulum e\u011fitimi<\/li>\n<li>\u00dcr\u00fcn sertifikalar\u0131 ve uyumluluk dok\u00fcmantasyonu<\/li>\n<li>\u00c7oklu inverter sistemleri i\u00e7in entegrasyon deste\u011fi<\/li>\n<li>String seviyesi izleme sistemi \u00f6nerileri<\/li>\n<\/ul>\n<\/div>\n<div class=\"simg-pop-btn\" style=\"top: 4826.7px; left: 24px; display: none;\"><\/div>\n<div class=\"simg-pop-btn\" style=\"top: 4826.7px; left: 24px; display: none;\"><\/div>","protected":false},"excerpt":{"rendered":"<p>ile maksimum sistem esnekli\u011fi sa\u011flay\u0131n <strong>VIOX VOPV1000-3\/3<\/strong>, birinci s\u0131n\u0131f bir <strong>3 Devreli Ba\u011f\u0131ms\u0131z Solar Birle\u015ftirme Kutusu<\/strong>. i\u00e7in tasarland\u0131 <strong>DC1000V<\/strong> sistemler, sa\u011flar <strong>3 tamamen izole edilmi\u015f giri\u015f ve \u00e7\u0131k\u0131\u015f<\/strong>, \u00e7oklu MPPT invert\u00f6rler ve karma\u015f\u0131k diziler i\u00e7in ideal koruma \u00e7\u00f6z\u00fcm\u00fc haline getirir.<\/p>\n<ul style=\"margin-top: 10px; margin-bottom: 10px;\">\n<li><strong>Konfig\u00fcrasyon:<\/strong> 3 Giri\u015f \/ 3 Ba\u011f\u0131ms\u0131z \u00c7\u0131k\u0131\u015f (3 giri\u015fli-3 \u00e7\u0131k\u0131\u015fl\u0131)<\/li>\n<li><strong>\u0130zolasyon:<\/strong> 100% Devreler aras\u0131nda Elektriksel Ayr\u0131m<\/li>\n<li><strong>\u00c7oklu MPPT Haz\u0131r:<\/strong> Do\u011frudan 3 ayr\u0131 invert\u00f6r giri\u015fine ba\u011flan\u0131r<\/li>\n<li><strong>Tam Koruma:<\/strong> 3x DC Anahtar\u0131, 3x Tip 2 SPD, 6x Sigorta<\/li>\n<li><strong>Ak\u0131m:<\/strong> Devre ba\u015f\u0131na 45A kapasite<\/li>\n<li><strong>Muhafaza:<\/strong> Geni\u015f Kapasiteli IP65 ABS (VOAT-39)<\/li>\n<\/ul>\n<p>En \u00fcst\u00fcn <strong>Geli\u015fmi\u015f solar kurulumlarda hata izolasyonu ve enerji hasad\u0131n\u0131 maksimize etmek i\u00e7in PV koruma \u00fcnitesi<\/strong> .<\/p>","protected":false},"featured_media":20935,"comment_status":"closed","ping_status":"closed","template":"","meta":{"inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[],"product_cat":[135,115],"product_tag":[],"class_list":{"0":"post-20932","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-combiner-box","7":"product_cat-new-energy-series","8":"desktop-align-left","9":"tablet-align-left","10":"mobile-align-left","12":"first","13":"instock","14":"shipping-taxable","15":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product\/20932","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/comments?post=20932"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/media\/20935"}],"wp:attachment":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/media?parent=20932"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product_brand?post=20932"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product_cat?post=20932"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product_tag?post=20932"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}