{"id":15741,"date":"2025-04-25T15:03:34","date_gmt":"2025-04-25T07:03:34","guid":{"rendered":"https:\/\/viox.com\/?post_type=product&#038;p=15741"},"modified":"2025-04-25T15:03:34","modified_gmt":"2025-04-25T07:03:34","slug":"ctb4430-ceramic-terminal-block","status":"publish","type":"product","link":"https:\/\/test.viox.com\/tr\/urun\/ctb4430-ceramic-terminal-block\/","title":{"rendered":"CTB4430 Seramik Terminal Blo\u011fu"},"content":{"rendered":"<div class=\"product-intro\">\n<p>CTB4430 Seramik Terminal Blo\u011fu, karma\u015f\u0131k end\u00fcstriyel uygulamalar i\u00e7in benzeri g\u00f6r\u00fclmemi\u015f esneklik ve g\u00fcvenilirlik sunarak \u00e7ok devreli elektrik ba\u011flant\u0131 teknolojisinin zirvesini temsil eder. Bu profesyonel s\u0131n\u0131f 4 giri\u015f-4 \u00e7\u0131k\u0131\u015fl\u0131 terminal blo\u011fu, ola\u011fan\u00fcst\u00fc 30A ak\u0131m ta\u015f\u0131ma kapasitesini \u00fcst\u00fcn termal stabilite ve ola\u011fan\u00fcst\u00fc elektrik yal\u0131t\u0131m \u00f6zellikleriyle birle\u015ftirerek, birden fazla y\u00fcksek ak\u0131m devresi gerektiren sofistike end\u00fcstriyel sistemler \u00fczerinde \u00e7al\u0131\u015fan m\u00fchendisler ve elektrik\u00e7iler i\u00e7in sars\u0131lmaz g\u00fcvenilirlik ve g\u00fcvenlik ile kesin bir se\u00e7im haline getirir.<\/p>\n<h2>Karma\u015f\u0131k End\u00fcstriyel Sistemler i\u00e7in Geni\u015fletilmi\u015f \u00c7ok Devreli Tasar\u0131m<\/h2>\n<p>CTB4430, optimum termal performans\u0131 ve ba\u011flant\u0131 b\u00fct\u00fcnl\u00fc\u011f\u00fcn\u00fc korurken d\u00f6rt ayr\u0131 devrede 30A'e kadar \u00f6nemli ak\u0131m y\u00fcklerini i\u015flemek i\u00e7in \u00f6zel olarak tasarlanm\u0131\u015f geli\u015fmi\u015f bir 4 giri\u015f-4 \u00e7\u0131k\u0131\u015f yap\u0131land\u0131rmas\u0131na sahiptir. Y\u00fcksek frekansl\u0131 seramik malzemeden hassas bir \u015fekilde \u00fcretilen bu terminal blo\u011fu, y\u00fcksek ak\u0131ml\u0131, y\u00fcksek s\u0131cakl\u0131kl\u0131 end\u00fcstriyel ortamlarda geleneksel plastik alternatiflerinden katlanarak daha iyi performans g\u00f6steren \u00fcst\u00fcn yal\u0131t\u0131m \u00f6zellikleri sunar. Seramik muhafaza, a\u015f\u0131r\u0131 termal ve elektriksel stres alt\u0131nda bile ya\u015flanma, \u00e7atlama ve deformasyona kar\u015f\u0131 tam diren\u00e7 sa\u011flayarak en karma\u015f\u0131k elektrik ba\u011flant\u0131lar\u0131n\u0131z i\u00e7in uzun vadeli stabilite ve g\u00fcvenli\u011fi garanti eder.<\/p>\n<p>Her terminal blo\u011fu, s\u00fcrekli y\u00fcksek ak\u0131m ko\u015fullar\u0131 alt\u0131nda optimum elektrik performans\u0131 i\u00e7in tasarlanm\u0131\u015f \u00f6nemli bak\u0131r \u00e7ekirdekli iletkenlere sahip sekiz a\u011f\u0131r hizmet ba\u011flant\u0131 noktas\u0131 i\u00e7erir. Dayan\u0131kl\u0131 demir kaplamal\u0131 \u00e7inko malzemeden \u00fcretilen M5 uyumlu vidal\u0131 terminaller, 30A uygulamalar i\u00e7in gerekli olan daha b\u00fcy\u00fck \u00f6l\u00e7\u00fcl\u00fc kablolarla g\u00fcvenli ba\u011flant\u0131lar olu\u015fturmak ve s\u00fcrd\u00fcrmek i\u00e7in ola\u011fan\u00fcst\u00fc s\u0131k\u0131\u015ft\u0131rma kuvveti sa\u011flar - titre\u015fime, termal d\u00f6ng\u00fcye ve y\u00fcksek ak\u0131m y\u00fcklerine maruz kald\u0131\u011f\u0131nda bile d\u00f6rt devrenin tamam\u0131nda m\u00fckemmel temas b\u00fct\u00fcnl\u00fc\u011f\u00fc sa\u011flar.<\/p>\n<h2>Temel \u00d6zellikler ve Teknik Avantajlar<\/h2>\n<ul>\n<li><strong>Maksimum Devre Esnekli\u011fi:<\/strong> D\u00f6rt giri\u015f, d\u00f6rt \u00e7\u0131k\u0131\u015f tasar\u0131m\u0131, tek bir entegre terminal blo\u011funda karma\u015f\u0131k \u00e7ok devreli g\u00fc\u00e7 da\u011f\u0131t\u0131m\u0131na olanak tan\u0131r<\/li>\n<li><strong>\u00d6nemli G\u00fcncel Kullan\u0131m:<\/strong> Devre ba\u015f\u0131na 30A de\u011feri, birden fazla y\u00fcksek ak\u0131m ba\u011flant\u0131s\u0131 gerektiren zorlu end\u00fcstriyel uygulamalar i\u00e7in ola\u011fan\u00fcst\u00fc kapasite sunar<\/li>\n<li><strong>Geni\u015fletilmi\u015f Terminal Blo\u011fu Tasar\u0131m\u0131:<\/strong> Uzat\u0131lm\u0131\u015f form fakt\u00f6r\u00fc (57mm \u00d7 25mm \u00d7 18.8mm), optimum aral\u0131\u011f\u0131 korurken d\u00f6rt tam devreyi bar\u0131nd\u0131r\u0131r<\/li>\n<li><strong>Geli\u015ftirilmi\u015f Montaj Sistemi:<\/strong> End\u00fcstriyel kontrol panellerinde g\u00fcvenli ve standart kurulum i\u00e7in dahili 29 mm aral\u0131kl\u0131 montaj delikleri<\/li>\n<li><strong>Y\u00fcksek Kapasiteli Tel Yerle\u015fimi:<\/strong> End\u00fcstriyel y\u00fcksek ak\u0131m uygulamalar\u0131 i\u00e7in gerekli olan 1,5 mm\u00b2'den 6 mm\u00b2'ye kadar \u00f6nemli tel \u00f6l\u00e7\u00fclerini destekler<\/li>\n<li><strong>C\u00f6mert Tel Giri\u015fi:<\/strong> 5mm \u00e7ap\u0131ndaki tel giri\u015f delikleri, daha kal\u0131n tellerin d\u00fczg\u00fcn bir \u015fekilde tak\u0131lmas\u0131n\u0131 kolayla\u015ft\u0131r\u0131r<\/li>\n<li><strong>M5 Vida Uyumlulu\u011fu:<\/strong> End\u00fcstriyel s\u0131n\u0131f vida boyutu, y\u00fcksek ak\u0131m ko\u015fullar\u0131 alt\u0131nda g\u00fcvenli ba\u011flant\u0131lar\u0131 korumak i\u00e7in geli\u015fmi\u015f s\u0131k\u0131\u015ft\u0131rma kuvveti sa\u011flar<\/li>\n<li><strong>Ola\u011fan\u00fcst\u00fc S\u0131cakl\u0131k Dayan\u0131m\u0131:<\/strong> Plastik klemenslerin kapasitesini \u00e7ok a\u015fan 750\u00b0C'ye kadar s\u0131cakl\u0131klarda s\u00fcrekli \u00e7al\u0131\u015fmaya dayan\u0131kl\u0131d\u0131r<\/li>\n<li><strong>\u00dcst\u00fcn Elektrik Yal\u0131t\u0131m\u0131:<\/strong> Seramik malzeme ola\u011fan\u00fcst\u00fc dielektrik dayan\u0131m\u0131 sa\u011flar ve biti\u015fik y\u00fcksek ak\u0131m devreleri aras\u0131nda ak\u0131m s\u0131z\u0131nt\u0131s\u0131n\u0131 \u00f6nler<\/li>\n<li><strong>Alev Geciktirici:<\/strong> Do\u011fal olarak yang\u0131na dayan\u0131kl\u0131 malzeme, kritik end\u00fcstriyel tesislerde tutu\u015fma veya alev yay\u0131lmas\u0131 riskini ortadan kald\u0131r\u0131r<\/li>\n<\/ul>\n<h2>Teknik \u00d6zellikler<\/h2>\n<table>\n<thead>\n<tr>\n<th>\u015eARTNAME<\/th>\n<th>MODEL<\/th>\n<th>UZUNLUK<\/th>\n<th>GEN\u0130\u015eL\u0130K<\/th>\n<th>Y\u00dcKSEKL\u0130K<\/th>\n<th>KABLOLAMA ARALI\u011eI<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1 Giri\u015f 1 \u00c7\u0131k\u0131\u015f 10A<\/td>\n<td>CTB1110<\/td>\n<td>19mm<\/td>\n<td>10mm<\/td>\n<td>15mm<\/td>\n<td>0,5-2,5 mm<sup>2<\/sup><\/td>\n<\/tr>\n<tr>\n<td>1 Giri\u015f 1 \u00c7\u0131k\u0131\u015f 30A<\/td>\n<td>CTB1130<\/td>\n<td>18mm<\/td>\n<td>14mm<\/td>\n<td>18mm<\/td>\n<td>0,5-6 mm<sup>2<\/sup><\/td>\n<\/tr>\n<tr>\n<td>2 Giri\u015f 2 \u00c7\u0131k\u0131\u015f 10A<\/td>\n<td>CTB2210<\/td>\n<td>20,7 mm<\/td>\n<td>18.9mm<\/td>\n<td>13.9mm<\/td>\n<td>0,5-2,5 mm<sup>2<\/sup><\/td>\n<\/tr>\n<tr>\n<td>2 Giri\u015f 2 \u00c7\u0131k\u0131\u015f 15A<\/td>\n<td>CTB2215<\/td>\n<td>28,4 mm<\/td>\n<td>20,4 mm<\/td>\n<td>16,3 mm<\/td>\n<td>0,5-4 mm<sup>2<\/sup><\/td>\n<\/tr>\n<tr>\n<td>2 Giri\u015f 2 \u00c7\u0131k\u0131\u015f 30A<\/td>\n<td>CTB2230<\/td>\n<td>31mm<\/td>\n<td>27mm<\/td>\n<td>18.9mm<\/td>\n<td>1,5-6 mm<sup>2<\/sup><\/td>\n<\/tr>\n<tr>\n<td>2 Giri\u015f 2 \u00c7\u0131k\u0131\u015f 60A<\/td>\n<td>CTB2260<\/td>\n<td>38,7 mm<\/td>\n<td>31mm<\/td>\n<td>22,7 mm<\/td>\n<td>2,5-16 mm<sup>2<\/sup><\/td>\n<\/tr>\n<tr>\n<td>2 Giri\u015f 2 \u00c7\u0131k\u0131\u015f 100A<\/td>\n<td>CTB22100<\/td>\n<td>41.1mm<\/td>\n<td>30,2 mm<\/td>\n<td>25,85 mm<\/td>\n<td>6-25mm<sup>2<\/sup><\/td>\n<\/tr>\n<tr>\n<td>3 Giri\u015f 3 \u00c7\u0131k\u0131\u015f 10A<\/td>\n<td>CTB3310<\/td>\n<td>31mm<\/td>\n<td>20mm<\/td>\n<td>14,3 mm<\/td>\n<td>0,5-2,5 mm<sup>2<\/sup><\/td>\n<\/tr>\n<tr>\n<td>3 Giri\u015f 3 \u00c7\u0131k\u0131\u015f 15A<\/td>\n<td>CTB3315<\/td>\n<td>35,5 mm<\/td>\n<td>20,3 mm<\/td>\n<td>20.2mm<\/td>\n<td>0,5-4 mm<sup>2<\/sup><\/td>\n<\/tr>\n<tr>\n<td>3 Giri\u015f 3 \u00c7\u0131k\u0131\u015f 30A<\/td>\n<td>CTB3330<\/td>\n<td>46,2 mm<\/td>\n<td>26,4 mm<\/td>\n<td>19,2 mm<\/td>\n<td>1,5-6 mm<sup>2<\/sup><\/td>\n<\/tr>\n<tr>\n<td>4 Giri\u015f 4 \u00c7\u0131k\u0131\u015f 30A<\/td>\n<td>CTB4430<\/td>\n<td>57mm<\/td>\n<td>25 mm<\/td>\n<td>18,8 mm<\/td>\n<td>1,5-6 mm<sup>2<\/sup><\/td>\n<\/tr>\n<tr>\n<td>5 Giri\u015f 5 \u00c7\u0131k\u0131\u015f 15A<\/td>\n<td>CTB5515<\/td>\n<td>50mm<\/td>\n<td>22mm<\/td>\n<td>13mm<\/td>\n<td>0,5-2,5 mm<sup>2<\/sup><\/td>\n<\/tr>\n<tr>\n<td>6 Giri\u015f 6 \u00c7\u0131k\u0131\u015f 15A<\/td>\n<td>CTB6615<\/td>\n<td>56,6 mm<\/td>\n<td>21mm<\/td>\n<td>13mm<\/td>\n<td>0,5-2,5 mm<sup>2<\/sup><\/td>\n<\/tr>\n<tr>\n<td>8 Giri\u015f 8 \u00c7\u0131k\u0131\u015f 15A<\/td>\n<td>CTB8815<\/td>\n<td>68mm<\/td>\n<td>21mm<\/td>\n<td>13mm<\/td>\n<td>0,5-2,5 mm<sup>2<\/sup><\/td>\n<\/tr>\n<tr>\n<td>10 Giri\u015f 10 \u00c7\u0131k\u0131\u015f 15A<\/td>\n<td>CTB101015<\/td>\n<td>88 mm<\/td>\n<td>18mm<\/td>\n<td>15mm<\/td>\n<td>0,5-3,5 mm<sup>2<\/sup><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>CTB4430 Detayl\u0131 \u00d6zellikler:<\/h3>\n<ul>\n<li><strong>G\u00fcncel De\u011ferlendirme:<\/strong> Devre ba\u015f\u0131na 30A<\/li>\n<li><strong>Konfig\u00fcrasyon:<\/strong> D\u00f6rt Giri\u015f, D\u00f6rt \u00c7\u0131k\u0131\u015f<\/li>\n<li><strong>Boyutlar:<\/strong> 57mm (U) \u00d7 25mm (G) \u00d7 18,8mm (Y)<\/li>\n<li><strong>Tel aral\u0131\u011f\u0131:<\/strong> 1,5-6 mm\u00b2<\/li>\n<li><strong>Tel Giri\u015f Delik \u00c7ap\u0131:<\/strong> 5 mm<\/li>\n<li><strong>G\u00f6vde Malzemesi:<\/strong> Y\u00fcksek frekansl\u0131 seramik<\/li>\n<li><strong>\u0130letken Malzeme:<\/strong> A\u011f\u0131r hizmet tipi bak\u0131r \u00e7ekirdek<\/li>\n<li><strong>Vida Malzemesi:<\/strong> Demir kaplamal\u0131 \u00e7inko<\/li>\n<li><strong>Vida Uyumlulu\u011fu:<\/strong> M5 di\u015f<\/li>\n<li><strong>Montaj Delik Mesafesi:<\/strong> Merkezden merkeze 29 mm<\/li>\n<li><strong>Uyumlu Kablo Tipleri:<\/strong> Hem yumu\u015fak hem de sert teller i\u00e7in uygundur<\/li>\n<li><strong>Maksimum \u00c7al\u0131\u015fma S\u0131cakl\u0131\u011f\u0131:<\/strong> 750\u00b0C<\/li>\n<li><strong>Dielektrik Dayan\u0131m\u0131:<\/strong> 3.5kV<\/li>\n<li><strong>\u0130zolasyon Direnci:<\/strong> 500VDC'de &gt;2000M\u03a9<\/li>\n<li><strong>Temas Direnci:<\/strong> &lt;0,2m\u03a9<\/li>\n<li><strong>Maksimum Tork:<\/strong> 1,8-2,2 N-m<\/li>\n<\/ul>\n<h2>\u00d6zel End\u00fcstriyel Uygulamalar<\/h2>\n<p>CTB4430 Seramik Terminal Blo\u011fu, \u00e7ok say\u0131da y\u00fcksek ak\u0131m devresinin, a\u015f\u0131r\u0131 s\u0131cakl\u0131k ko\u015fullar\u0131n\u0131n ve mutlak g\u00fcvenilirli\u011fin temel gereksinimler oldu\u011fu karma\u015f\u0131k end\u00fcstriyel uygulamalar i\u00e7in \u00f6zel olarak tasarlanm\u0131\u015ft\u0131r:<\/p>\n<ul>\n<li><strong>\u0130leri Kontrol Sistemleri:<\/strong> Birden fazla izole y\u00fcksek ak\u0131m devresi gerektiren end\u00fcstriyel kontrol panelleri<\/li>\n<li><strong>\u00dcretim Ekipmanlar\u0131:<\/strong> Birden fazla g\u00fc\u00e7 ve kontrol devresi gerektiren karma\u015f\u0131k makineler<\/li>\n<li><strong>\u00c7ok Fazl\u0131 G\u00fc\u00e7 Da\u011f\u0131t\u0131m\u0131:<\/strong> N\u00f6tr veya \u00f6zel d\u00f6rt fazl\u0131 uygulamalara sahip d\u00f6rt telli \u00fc\u00e7 fazl\u0131 sistemler<\/li>\n<li><strong>End\u00fcstriyel Otomasyon:<\/strong> \u00c7e\u015fitli otomasyon bile\u015fenleri i\u00e7in birden fazla izole g\u00fc\u00e7 devresi gerektiren sistemler<\/li>\n<li><strong>\u00c7ok B\u00f6lgeli Is\u0131tma Sistemleri:<\/strong> Birden fazla ba\u011f\u0131ms\u0131z \u0131s\u0131tma b\u00f6lgesine sahip end\u00fcstriyel f\u0131r\u0131nlar ve ocaklar<\/li>\n<li><strong>Karma\u015f\u0131k Motor Kontrol\u00fc:<\/strong> \u00c7oklu motorlar\u0131 veya \u00e7ok h\u0131zl\u0131 motor d\u00fczenlemelerini kontrol eden uygulamalar<\/li>\n<li><strong>A\u011f\u0131r ekipman:<\/strong> Birden fazla y\u00fcksek g\u00fc\u00e7 devresine sahip madencilik, in\u015faat ve tar\u0131m ekipmanlar\u0131<\/li>\n<li><strong>End\u00fcstriyel Test Ekipmanlar\u0131:<\/strong> Birden fazla izole g\u00fc\u00e7 kanal\u0131 gerektiren sistemler<\/li>\n<\/ul>\n<h2>Profesyonel Kurulum Y\u00f6nergeleri<\/h2>\n<p>Karma\u015f\u0131k \u00e7ok devreli y\u00fcksek ak\u0131m uygulamalar\u0131nda optimum performans, g\u00fcvenlik ve elektrik y\u00f6netmeliklerine uygunluk i\u00e7in bu \u00f6zel kurulum y\u00f6nergelerini izleyin:<\/p>\n<ol>\n<li>Montaj y\u00fczeyinin sa\u011flam, \u0131s\u0131ya dayan\u0131kl\u0131 oldu\u011fundan ve \u0131s\u0131 da\u011f\u0131l\u0131m\u0131 i\u00e7in yeterli alan sa\u011flad\u0131\u011f\u0131ndan emin olun<\/li>\n<li>End\u00fcstriyel panellere g\u00fcvenli ba\u011flant\u0131 i\u00e7in entegre 29 mm montaj deliklerini kullan\u0131n<\/li>\n<li>Farkl\u0131 elektrik potansiyelleri aras\u0131nda uygun ayr\u0131m\u0131 sa\u011flamak i\u00e7in devre d\u00fczenini dikkatlice planlay\u0131n<\/li>\n<li>Kablolar\u0131 uygun uzunlukta soyun (daha b\u00fcy\u00fck \u00f6l\u00e7\u00fcl\u00fc iletkenler i\u00e7in tipik olarak 10-12 mm)<\/li>\n<li>\u00c7ok telli iletkenlerde, optimum ba\u011flant\u0131 b\u00fct\u00fcnl\u00fc\u011f\u00fc i\u00e7in y\u00fcks\u00fck kullan\u0131n veya \u00f6nceden b\u00fck\u00fcn<\/li>\n<li>\u0130letken hasar\u0131n\u0131 \u00f6nlemek i\u00e7in kablolar\u0131 yerle\u015ftirmeden \u00f6nce terminal vidalar\u0131n\u0131 tamamen gev\u015fetin<\/li>\n<li>A\u00e7\u0131kta kalan iletkenin seramik muhafazan\u0131n d\u0131\u015f\u0131na ta\u015fmad\u0131\u011f\u0131ndan emin olarak kabloyu terminal a\u00e7\u0131kl\u0131\u011f\u0131na tamamen yerle\u015ftirin<\/li>\n<li>M5 vidalar\u0131 kademeli olarak 1,8-2,2 N-m nihai torka kadar s\u0131k\u0131n<\/li>\n<li>Hem g\u00f6rsel inceleme hem de mekanik test yoluyla ba\u011flant\u0131 b\u00fct\u00fcnl\u00fc\u011f\u00fcn\u00fc do\u011frulay\u0131n<\/li>\n<li>Gelecekteki bak\u0131m ve sorun giderme i\u015flemleri i\u00e7in her devreyi a\u00e7\u0131k\u00e7a etiketleyin<\/li>\n<li>Y\u00fcksek ak\u0131m ba\u011flant\u0131lar\u0131n\u0131n incelenmesi ve yeniden torklanmas\u0131 i\u00e7in d\u00fczenli bir bak\u0131m program\u0131 uygulay\u0131n<\/li>\n<\/ol>\n<h2>CTB4430 Avantaj\u0131: E\u015fsiz \u00c7ok Devreli Esneklik<\/h2>\n<p>CTB4430 Seramik Terminal Blo\u011fu, sars\u0131lmaz g\u00fcvenilirli\u011fe sahip birden fazla y\u00fcksek ak\u0131m devresi gerektiren karma\u015f\u0131k elektrik tesisatlar\u0131 i\u00e7in kesin \u00e7\u00f6z\u00fcm\u00fc temsil eder. D\u00f6rt ayr\u0131 30A devre, \u00fcst\u00fcn s\u0131cakl\u0131k direnci ve tavizsiz ba\u011flant\u0131 b\u00fct\u00fcnl\u00fc\u011f\u00fcn\u00fcn benzersiz kombinasyonu, hem devre karma\u015f\u0131kl\u0131\u011f\u0131n\u0131n hem de mutlak g\u00fcvenilirli\u011fin tart\u0131\u015f\u0131lmaz gereksinimler oldu\u011fu sofistike end\u00fcstriyel uygulamalar i\u00e7in temel se\u00e7im olmas\u0131n\u0131 sa\u011flar.<\/p>\n<p>En zorlu ve karma\u015f\u0131k end\u00fcstriyel uygulamalar\u0131n\u0131z i\u00e7in en \u00fcst d\u00fczeyde g\u00fcvenli, g\u00fcvenilir elektrik ba\u011flant\u0131s\u0131 \u00e7\u00f6z\u00fcm\u00fc sa\u011flamak \u00fczere birinci s\u0131n\u0131f seramik terminal blo\u011fu teknolojimizin m\u00fchendislik m\u00fckemmelli\u011fine g\u00fcvenin. CTB4430, g\u00fcn\u00fcm\u00fcz\u00fcn sofistike end\u00fcstriyel g\u00fc\u00e7 ve kontrol gereksinimleri i\u00e7in \u00e7ok devreli terminal blo\u011fu performans\u0131nda yeni bir standart olu\u015fturmaktad\u0131r.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>VIOX CTB4430 Seramik Terminal Blo\u011fu, karma\u015f\u0131k y\u00fcksek ak\u0131ml\u0131 \u00e7oklu devre ihtiya\u00e7lar\u0131 i\u00e7in 4 giri\u015f-4 \u00e7\u0131k\u0131\u015f, 30A tasar\u0131m sunar. 750\u00b0C \u0131s\u0131 direnci ile end\u00fcstriyel otomasyon ve \u00e7ok fazl\u0131 sistemler i\u00e7in idealdir. Zorlu y\u00fcksek s\u0131cakl\u0131k ortamlar\u0131nda g\u00fcvenilir, g\u00fcvenli ba\u011flant\u0131lar i\u00e7in VIOX'a g\u00fcvenin.<\/p>","protected":false},"featured_media":15742,"comment_status":"closed","ping_status":"closed","template":"","meta":{"inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[],"product_cat":[214],"product_tag":[],"class_list":{"0":"post-15741","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ceramic-terminal-block","7":"desktop-align-left","8":"tablet-align-left","9":"mobile-align-left","11":"first","12":"instock","13":"shipping-taxable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product\/15741","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/comments?post=15741"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/media\/15742"}],"wp:attachment":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/media?parent=15741"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product_brand?post=15741"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product_cat?post=15741"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product_tag?post=15741"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}