{"id":15733,"date":"2025-04-25T01:12:50","date_gmt":"2025-04-24T17:12:50","guid":{"rendered":"https:\/\/viox.com\/?post_type=product&#038;p=15733"},"modified":"2025-04-25T01:13:17","modified_gmt":"2025-04-24T17:13:17","slug":"ctb22100-ceramic-terminal-block","status":"publish","type":"product","link":"https:\/\/test.viox.com\/tr\/urun\/ctb22100-ceramic-terminal-block\/","title":{"rendered":"CTB22100 Seramik Terminal Blo\u011fu"},"content":{"rendered":"<div class=\"product-intro\">\n<p>CTB22100 Seramik Terminal Blo\u011fu, en zorlu end\u00fcstriyel ve ticari g\u00fc\u00e7 uygulamalar\u0131 i\u00e7in \u00f6zel olarak tasarlanm\u0131\u015f, y\u00fcksek kapasiteli elektrik ba\u011flant\u0131 teknolojisindeki en son ba\u015far\u0131y\u0131 temsil eder. Bu birinci s\u0131n\u0131f 2 giri\u015f-2 \u00e7\u0131k\u0131\u015fl\u0131 klemens, 100A ak\u0131m de\u011feriyle ola\u011fan\u00fcst\u00fc performans sunarken, ola\u011fan\u00fcst\u00fc termal kararl\u0131l\u0131\u011f\u0131 \u00fcst\u00fcn elektrik yal\u0131t\u0131m \u00f6zellikleriyle birle\u015ftirerek geleneksel klemenslerin h\u0131zla ar\u0131zalanaca\u011f\u0131 kritik y\u00fcksek amperli g\u00fc\u00e7 da\u011f\u0131t\u0131m\u0131 i\u00e7in kesin bir \u00e7\u00f6z\u00fcm olu\u015fturur.<\/p>\n<h2>A\u015f\u0131r\u0131 G\u00fc\u00e7 Gereksinimleri i\u00e7in Maksimum Kapasiteli Tasar\u0131m<\/h2>\n<p>CTB22100, optimum termal \u00f6zellikleri ve ba\u011flant\u0131 g\u00fcvenilirli\u011fini korurken 100A'e kadar a\u015f\u0131r\u0131 ak\u0131m y\u00fcklerini i\u015flemek i\u00e7in \u00f6zel olarak tasarlanm\u0131\u015f 2 giri\u015f-2 \u00e7\u0131k\u0131\u015f konfig\u00fcrasyonuna sahiptir. Y\u00fcksek frekansl\u0131 seramik malzemeden hassas bir \u015fekilde \u00fcretilen bu terminal blo\u011fu, plastik veya fenolik alternatiflerden katlanarak daha iyi performans g\u00f6steren benzersiz yal\u0131t\u0131m \u00f6zellikleri ve \u0131s\u0131 direnci sunarak, daha d\u00fc\u015f\u00fck malzemelerin hemen bozulaca\u011f\u0131 veya ciddi g\u00fcvenlik tehlikeleri yarataca\u011f\u0131 y\u00fcksek ak\u0131ml\u0131, y\u00fcksek s\u0131cakl\u0131kl\u0131 end\u00fcstriyel ortamlar i\u00e7in gerekli hale getirir.<\/p>\n<p>Her CTB22100, a\u015f\u0131r\u0131 ak\u0131m y\u00fckleri alt\u0131nda maksimum elektrik performans\u0131 i\u00e7in \u00f6zel olarak tasarlanm\u0131\u015f b\u00fcy\u00fck bak\u0131r \u00e7ekirdekli iletkenlere sahip end\u00fcstriyel s\u0131n\u0131f ba\u011flant\u0131 noktalar\u0131 i\u00e7erir. Sa\u011flam demir kaplamal\u0131 \u00e7inko malzemeden \u00fcretilen M7 uyumlu vidal\u0131 terminaller, 100A uygulamalar i\u00e7in gerekli olan \u00f6nemli \u00f6l\u00e7\u00fcdeki tellerle g\u00fcvenli ba\u011flant\u0131lar olu\u015fturmak ve s\u00fcrd\u00fcrmek i\u00e7in gerekli olan ola\u011fan\u00fcst\u00fc s\u0131k\u0131\u015ft\u0131rma bas\u0131nc\u0131n\u0131 sa\u011flar - standart terminal bloklar\u0131n\u0131n feci \u015fekilde ar\u0131zalanmas\u0131na neden olabilecek ko\u015fullar alt\u0131nda m\u00fckemmel temas b\u00fct\u00fcnl\u00fc\u011f\u00fc sa\u011flar.<\/p>\n<h2>Temel \u00d6zellikler ve Teknik Avantajlar<\/h2>\n<ul>\n<li><strong>Maksimum Ak\u0131m Kapasitesi:<\/strong> 100A de\u011feri, en zorlu end\u00fcstriyel g\u00fc\u00e7 uygulamalar\u0131 i\u00e7in ola\u011fan\u00fcst\u00fc ak\u0131m i\u015fleme kapasitesi sa\u011flar<\/li>\n<li><strong>B\u00fcy\u00fck \u00d6l\u00e7ekli Tel Konaklama:<\/strong> Y\u00fcksek amperajl\u0131 end\u00fcstriyel kurulumlar i\u00e7in gerekli olan 6mm\u00b2'den 25mm\u00b2'ye kadar \u00f6nemli kablo \u00f6l\u00e7\u00fclerini destekler<\/li>\n<li><strong>Optimize Edilmi\u015f Tel Giri\u015fi:<\/strong> 6 mm \u00e7ap\u0131ndaki kablo giri\u015f delikleri a\u011f\u0131r iletkenlerin sorunsuz montaj\u0131na olanak sa\u011flar<\/li>\n<li><strong>\u00c7ift Devre Yap\u0131land\u0131rmas\u0131:<\/strong> \u0130ki giri\u015fli, iki \u00e7\u0131k\u0131\u015fl\u0131 tasar\u0131m, y\u00fcksek ak\u0131ml\u0131 end\u00fcstriyel ortamlarda verimli g\u00fc\u00e7 da\u011f\u0131t\u0131m\u0131 sa\u011flar<\/li>\n<li><strong>M7 Vida Uyumlulu\u011fu:<\/strong> End\u00fcstriyel s\u0131n\u0131f vida boyutu, a\u015f\u0131r\u0131 ak\u0131m ko\u015fullar\u0131 alt\u0131nda m\u00fckemmel ba\u011flant\u0131lar\u0131 korumak i\u00e7in \u00fcst\u00fcn s\u0131k\u0131\u015ft\u0131rma kuvveti sa\u011flar<\/li>\n<li><strong>E\u015fsiz S\u0131cakl\u0131k Dayan\u0131m\u0131:<\/strong> 750\u00b0C'ye kadar s\u0131cakl\u0131klarda bozulma olmadan s\u00fcrekli \u00e7al\u0131\u015fmaya dayan\u0131r<\/li>\n<li><strong>\u00dcst\u00fcn Elektrik Yal\u0131t\u0131m\u0131:<\/strong> Seramik malzeme ola\u011fan\u00fcst\u00fc dielektrik dayan\u0131m\u0131 sa\u011flayarak y\u00fcksek s\u0131cakl\u0131k ve gerilimlerde bile ak\u0131m ka\u00e7a\u011f\u0131n\u0131 ortadan kald\u0131r\u0131r<\/li>\n<li><strong>Maksimum Boyutsal Kararl\u0131l\u0131k:<\/strong> \u00d6nemli genel boyutlar (41,1 mm \u00d7 30,2 mm \u00d7 25,85 mm) geli\u015fmi\u015f mekanik g\u00fc\u00e7 ve \u00fcst\u00fcn \u0131s\u0131 da\u011f\u0131l\u0131m\u0131 sa\u011flar<\/li>\n<li><strong>Do\u011fal Alev Direnci:<\/strong> Do\u011fal olarak ate\u015fe dayan\u0131kl\u0131 seramik malzeme, kritik y\u00fcksek ak\u0131m tesisatlar\u0131nda tutu\u015fma riskini ortadan kald\u0131r\u0131r<\/li>\n<li><strong>Tam Kimyasal Diren\u00e7:<\/strong> End\u00fcstriyel ya\u011flara, solventlere ve a\u015f\u0131nd\u0131r\u0131c\u0131 maddelere kar\u015f\u0131 dayan\u0131kl\u0131d\u0131r<\/li>\n<\/ul>\n<h2>Teknik \u00d6zellikler<\/h2>\n<table>\n<thead>\n<tr>\n<th>\u015eARTNAME<\/th>\n<th>MODEL<\/th>\n<th>UZUNLUK<\/th>\n<th>GEN\u0130\u015eL\u0130K<\/th>\n<th>Y\u00dcKSEKL\u0130K<\/th>\n<th>KABLOLAMA ARALI\u011eI<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1 Giri\u015f 1 \u00c7\u0131k\u0131\u015f 10A<\/td>\n<td>CTB1110<\/td>\n<td>19mm<\/td>\n<td>10mm<\/td>\n<td>15mm<\/td>\n<td>0,5-2,5 mm<sup>2<\/sup><\/td>\n<\/tr>\n<tr>\n<td>1 Giri\u015f 1 \u00c7\u0131k\u0131\u015f 30A<\/td>\n<td>CTB1130<\/td>\n<td>18mm<\/td>\n<td>14mm<\/td>\n<td>18mm<\/td>\n<td>0,5-6 mm<sup>2<\/sup><\/td>\n<\/tr>\n<tr>\n<td>2 Giri\u015f 2 \u00c7\u0131k\u0131\u015f 10A<\/td>\n<td>CTB2210<\/td>\n<td>20,7 mm<\/td>\n<td>18.9mm<\/td>\n<td>13.9mm<\/td>\n<td>0,5-2,5 mm<sup>2<\/sup><\/td>\n<\/tr>\n<tr>\n<td>2 Giri\u015f 2 \u00c7\u0131k\u0131\u015f 15A<\/td>\n<td>CTB2215<\/td>\n<td>28,4 mm<\/td>\n<td>20,4 mm<\/td>\n<td>16,3 mm<\/td>\n<td>0,5-4 mm<sup>2<\/sup><\/td>\n<\/tr>\n<tr>\n<td>2 Giri\u015f 2 \u00c7\u0131k\u0131\u015f 30A<\/td>\n<td>CTB2230<\/td>\n<td>31mm<\/td>\n<td>27mm<\/td>\n<td>18.9mm<\/td>\n<td>1,5-6 mm<sup>2<\/sup><\/td>\n<\/tr>\n<tr>\n<td>2 Giri\u015f 2 \u00c7\u0131k\u0131\u015f 60A<\/td>\n<td>CTB2260<\/td>\n<td>38,7 mm<\/td>\n<td>31mm<\/td>\n<td>22,7 mm<\/td>\n<td>2,5-16 mm<sup>2<\/sup><\/td>\n<\/tr>\n<tr>\n<td>2 Giri\u015f 2 \u00c7\u0131k\u0131\u015f 100A<\/td>\n<td>CTB22100<\/td>\n<td>41.1mm<\/td>\n<td>30,2 mm<\/td>\n<td>25,85 mm<\/td>\n<td>6-25mm<sup>2<\/sup><\/td>\n<\/tr>\n<tr>\n<td>3 Giri\u015f 3 \u00c7\u0131k\u0131\u015f 10A<\/td>\n<td>CTB3310<\/td>\n<td>31mm<\/td>\n<td>20mm<\/td>\n<td>14,3 mm<\/td>\n<td>0,5-2,5 mm<sup>2<\/sup><\/td>\n<\/tr>\n<tr>\n<td>3 Giri\u015f 3 \u00c7\u0131k\u0131\u015f 15A<\/td>\n<td>CTB3315<\/td>\n<td>35,5 mm<\/td>\n<td>20,3 mm<\/td>\n<td>20.2mm<\/td>\n<td>0,5-4 mm<sup>2<\/sup><\/td>\n<\/tr>\n<tr>\n<td>3 Giri\u015f 3 \u00c7\u0131k\u0131\u015f 30A<\/td>\n<td>CTB3330<\/td>\n<td>46,2 mm<\/td>\n<td>26,4 mm<\/td>\n<td>19,2 mm<\/td>\n<td>1,5-6 mm<sup>2<\/sup><\/td>\n<\/tr>\n<tr>\n<td>4 Giri\u015f 4 \u00c7\u0131k\u0131\u015f 30A<\/td>\n<td>CTB4430<\/td>\n<td>57mm<\/td>\n<td>25 mm<\/td>\n<td>18,8 mm<\/td>\n<td>1,5-6 mm<sup>2<\/sup><\/td>\n<\/tr>\n<tr>\n<td>5 Giri\u015f 5 \u00c7\u0131k\u0131\u015f 15A<\/td>\n<td>CTB5515<\/td>\n<td>50mm<\/td>\n<td>22mm<\/td>\n<td>13mm<\/td>\n<td>0,5-2,5 mm<sup>2<\/sup><\/td>\n<\/tr>\n<tr>\n<td>6 Giri\u015f 6 \u00c7\u0131k\u0131\u015f 15A<\/td>\n<td>CTB6615<\/td>\n<td>56,6 mm<\/td>\n<td>21mm<\/td>\n<td>13mm<\/td>\n<td>0,5-2,5 mm<sup>2<\/sup><\/td>\n<\/tr>\n<tr>\n<td>8 Giri\u015f 8 \u00c7\u0131k\u0131\u015f 15A<\/td>\n<td>CTB8815<\/td>\n<td>68mm<\/td>\n<td>21mm<\/td>\n<td>13mm<\/td>\n<td>0,5-2,5 mm<sup>2<\/sup><\/td>\n<\/tr>\n<tr>\n<td>10 Giri\u015f 10 \u00c7\u0131k\u0131\u015f 15A<\/td>\n<td>CTB101015<\/td>\n<td>88 mm<\/td>\n<td>18mm<\/td>\n<td>15mm<\/td>\n<td>0,5-3,5 mm<sup>2<\/sup><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>CTB22100 Detayl\u0131 \u00d6zellikler:<\/h3>\n<ul>\n<li><strong>G\u00fcncel De\u011ferlendirme:<\/strong> 100A<\/li>\n<li><strong>Konfig\u00fcrasyon:<\/strong> \u0130ki giri\u015f, \u0130ki \u00e7\u0131k\u0131\u015f<\/li>\n<li><strong>Boyutlar:<\/strong> 41,1 mm (U) \u00d7 30,2 mm (G) \u00d7 25,85 mm (Y)<\/li>\n<li><strong>Tel aral\u0131\u011f\u0131:<\/strong> 6-25mm\u00b2<\/li>\n<li><strong>Tel Giri\u015f Delik \u00c7ap\u0131:<\/strong> 6mm<\/li>\n<li><strong>G\u00f6vde Malzemesi:<\/strong> Y\u00fcksek frekansl\u0131 seramik<\/li>\n<li><strong>\u0130letken Malzeme:<\/strong> A\u011f\u0131r hizmet tipi bak\u0131r \u00e7ekirdek<\/li>\n<li><strong>Vida Malzemesi:<\/strong> Demir kaplamal\u0131 \u00e7inko<\/li>\n<li><strong>Vida Uyumlulu\u011fu:<\/strong> M7 di\u015f<\/li>\n<li><strong>Uyumlu Kablo Tipleri:<\/strong> Hem yumu\u015fak hem de sert teller i\u00e7in uygundur<\/li>\n<li><strong>Maksimum \u00c7al\u0131\u015fma S\u0131cakl\u0131\u011f\u0131:<\/strong> 750\u00b0C<\/li>\n<li><strong>Dielektrik Dayan\u0131m\u0131:<\/strong> 5kV<\/li>\n<li><strong>\u0130zolasyon Direnci:<\/strong> 500VDC'de &gt;5000M\u03a9<\/li>\n<li><strong>Temas Direnci:<\/strong> &lt;0,1m\u03a9<\/li>\n<li><strong>Maksimum Tork:<\/strong> 3,5-4,0 N-m<\/li>\n<li><strong>Gerilim De\u011feri:<\/strong> 1000V AC\/DC<\/li>\n<\/ul>\n<h2>A\u011f\u0131r End\u00fcstriyel Uygulamalar<\/h2>\n<p>CTB22100 Seramik Terminal Blo\u011fu, maksimum ak\u0131m kapasitesi, a\u015f\u0131r\u0131 termal ko\u015fullar ve mutlak ba\u011flant\u0131 g\u00fcvenilirli\u011finin temel gereksinimler oldu\u011fu \u00f6zel end\u00fcstriyel uygulamalar i\u00e7in \u00f6zel olarak tasarlanm\u0131\u015ft\u0131r:<\/p>\n<ul>\n<li><strong>A\u011f\u0131r \u0130malat:<\/strong> \u00c7elik fabrikalar\u0131, d\u00f6k\u00fcmhaneler ve b\u00fcy\u00fck \u00fcretim tesislerinde ana g\u00fc\u00e7 da\u011f\u0131t\u0131m\u0131<\/li>\n<li><strong>End\u00fcstriyel G\u00fc\u00e7 Merkezleri:<\/strong> Y\u00fcksek kapasiteli end\u00fcstriyel g\u00fc\u00e7 da\u011f\u0131t\u0131m sistemlerinde birincil besleme ba\u011flant\u0131lar\u0131<\/li>\n<li><strong>A\u011f\u0131r ekipman:<\/strong> B\u00fcy\u00fck elektrik motorlar\u0131, end\u00fcstriyel pompalar ve a\u011f\u0131r makineler i\u00e7in g\u00fc\u00e7 ba\u011flant\u0131lar\u0131<\/li>\n<li><strong>Y\u00fcksek Kapasiteli Is\u0131tma Sistemleri:<\/strong> End\u00fcstriyel f\u0131r\u0131nlar ve b\u00fcy\u00fck \u00f6l\u00e7ekli \u0131s\u0131tma uygulamalar\u0131 i\u00e7in birincil ba\u011flant\u0131lar<\/li>\n<li><strong>G\u00fc\u00e7 \u00dcretimi:<\/strong> Enerji santralleri, jenerat\u00f6r istasyonlar\u0131 ve trafo merkezi ekipmanlar\u0131ndaki ba\u011flant\u0131 noktalar\u0131<\/li>\n<li><strong>Metalurjik \u0130\u015fleme:<\/strong> Metal eritme, d\u00f6vme ve \u0131s\u0131l i\u015flem tesislerindeki elektrik ba\u011flant\u0131lar\u0131<\/li>\n<li><strong>A\u011f\u0131r Nakliye:<\/strong> Demiryolu sistemlerinde, nakliye tesislerinde ve a\u011f\u0131r vas\u0131ta \u00fcretiminde g\u00fc\u00e7 da\u011f\u0131t\u0131m\u0131<\/li>\n<li><strong>Madencilik Operasyonlar\u0131:<\/strong> Madencilik ekipmanlar\u0131 ve cevher i\u015fleme makineleri i\u00e7in ana elektrik beslemeleri<\/li>\n<\/ul>\n<h2>\u00d6zel Kurulum Y\u00f6nergeleri<\/h2>\n<p>A\u015f\u0131r\u0131 y\u00fcksek ak\u0131m uygulamalar\u0131nda optimum g\u00fcvenlik, performans ve elektrik y\u00f6netmeliklerine uygunluk i\u00e7in bu \u00f6zel kurulum y\u00f6nergelerini izleyin:<\/p>\n<ol>\n<li>Montaj yerinin \u00f6nemli \u00f6l\u00e7\u00fcde hava ak\u0131\u015f\u0131 ve termal da\u011f\u0131l\u0131m kapasitesi sa\u011flad\u0131\u011f\u0131ndan emin olun<\/li>\n<li>\u0130letkenleri uygun uzunlukta soyun (b\u00fcy\u00fck \u00f6l\u00e7\u00fcl\u00fc kablolar i\u00e7in tipik olarak 15-20 mm)<\/li>\n<li>\u00c7ok telli iletkenler i\u00e7in profesyonel kalitede s\u0131k\u0131\u015ft\u0131rma y\u00fcks\u00fckleri veya kalaylama teknikleri kullan\u0131n<\/li>\n<li>Kablo yerle\u015ftirmeye \u00e7al\u0131\u015fmadan \u00f6nce terminal vidalar\u0131n\u0131 tamamen gev\u015fetin<\/li>\n<li>\u0130letkenleri terminal a\u00e7\u0131kl\u0131klar\u0131na tamamen yerle\u015ftirin, i\u00e7 temas y\u00fczeylerine do\u011fru oturdu\u011fundan emin olun<\/li>\n<li>M7 vidalar\u0131n\u0131 3,5-4,0 N-m nihai tork de\u011ferine kadar kademeli olarak s\u0131k\u0131n<\/li>\n<li>Hem g\u00f6rsel inceleme hem de mekanik test yoluyla ba\u011flant\u0131 b\u00fct\u00fcnl\u00fc\u011f\u00fcn\u00fc do\u011frulay\u0131n<\/li>\n<li>100A ba\u011flant\u0131lar\u0131n\u0131n incelenmesi ve yeniden torklanmas\u0131 i\u00e7in zorunlu bir bak\u0131m program\u0131 uygulay\u0131n<\/li>\n<li>Biti\u015fik y\u00fcksek kapasiteli terminal bloklar\u0131 aras\u0131nda en az 20 mm bo\u015fluk b\u0131rak\u0131n<\/li>\n<li>100A de\u011ferine yak\u0131n s\u00fcrekli \u00e7al\u0131\u015fma i\u00e7in ek termal izleme \u00f6nlemleri uygulay\u0131n<\/li>\n<\/ol>\n<h2>Kritik G\u00fc\u00e7 Uygulamalar\u0131 i\u00e7in Nihai \u00c7\u00f6z\u00fcm<\/h2>\n<p>Maksimum ak\u0131m kapasitesi ve mutlak g\u00fcvenilirli\u011fin tart\u0131\u015f\u0131lmaz gereklilikler oldu\u011fu elektrik tesisatlar\u0131 i\u00e7in CTB22100 Seramik Terminal Blo\u011fu kesin \u00e7\u00f6z\u00fcm\u00fc temsil eder. Ola\u011fan\u00fcst\u00fc 100A ak\u0131m kapasitesi, \u00fcst\u00fcn s\u0131cakl\u0131k direnci ve tavizsiz ba\u011flant\u0131 b\u00fct\u00fcnl\u00fc\u011f\u00fcn\u00fcn benzersiz kombinasyonu, ba\u011flant\u0131 ar\u0131zas\u0131n\u0131n felaketle sonu\u00e7lanabilece\u011fi kritik end\u00fcstriyel uygulamalar i\u00e7in tek uygun se\u00e7enek olmas\u0131n\u0131 sa\u011flar.<\/p>\n<p>En zorlu y\u00fcksek kapasiteli end\u00fcstriyel uygulamalar\u0131n\u0131z i\u00e7in en \u00fcst d\u00fczeyde g\u00fcvenli, g\u00fcvenilir elektrik ba\u011flant\u0131s\u0131 \u00e7\u00f6z\u00fcm\u00fc sa\u011flamak \u00fczere birinci s\u0131n\u0131f seramik terminal blo\u011fu teknolojimizin m\u00fchendislik m\u00fckemmelli\u011fine g\u00fcvenin. CTB22100, g\u00fcn\u00fcm\u00fcz\u00fcn en zorlu end\u00fcstriyel g\u00fc\u00e7 gereksinimleri i\u00e7in y\u00fcksek ak\u0131ml\u0131 terminal blo\u011fu performans\u0131nda yeni bir standart olu\u015fturmaktad\u0131r.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>VIOX CTB22100 Seramik Terminal Blo\u011fu, a\u015f\u0131r\u0131 y\u00fcksek ak\u0131m ihtiya\u00e7lar\u0131 i\u00e7in 2 giri\u015f-2 \u00e7\u0131k\u0131\u015f, 100A tasar\u0131m sunar. 750\u00b0C \u0131s\u0131 direnci ile a\u011f\u0131r imalat ve enerji \u00fcretimi i\u00e7in idealdir. En zorlu y\u00fcksek s\u0131cakl\u0131kl\u0131 end\u00fcstriyel ortamlarda e\u015fsiz, g\u00fcvenli ba\u011flant\u0131lar i\u00e7in VIOX'a g\u00fcvenin.<\/p>","protected":false},"featured_media":15734,"comment_status":"closed","ping_status":"closed","template":"","meta":{"inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[],"product_cat":[214],"product_tag":[],"class_list":{"0":"post-15733","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ceramic-terminal-block","7":"desktop-align-left","8":"tablet-align-left","9":"mobile-align-left","11":"first","12":"instock","13":"shipping-taxable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product\/15733","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/comments?post=15733"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/media\/15734"}],"wp:attachment":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/media?parent=15733"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product_brand?post=15733"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product_cat?post=15733"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product_tag?post=15733"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}