{"id":15705,"date":"2025-04-24T21:41:32","date_gmt":"2025-04-24T13:41:32","guid":{"rendered":"https:\/\/viox.com\/?post_type=product&#038;p=15705"},"modified":"2025-04-24T21:41:32","modified_gmt":"2025-04-24T13:41:32","slug":"c45-insert-in-copper-lug","status":"publish","type":"product","link":"https:\/\/test.viox.com\/tr\/urun\/c45-insert-in-copper-lug\/","title":{"rendered":"C45 Yerle\u015fik Bak\u0131r Pabu\u00e7"},"content":{"rendered":"<div class=\"product-intro\">\n<p>Modern elektrik sistemlerinde, \u00f6zellikle de kontrol panelleri ve da\u011f\u0131t\u0131m panolar\u0131nda g\u00fcvenilir ve emniyetli elektrik ba\u011flant\u0131lar\u0131n\u0131n sa\u011flanmas\u0131 esast\u0131r. Vidal\u0131 terminaller ve kelep\u00e7e tarz\u0131 terminal bloklar\u0131 uygun ba\u011flant\u0131 noktalar\u0131 sunarken, ince telli bak\u0131r iletkenlerin do\u011frudan bunlara sonland\u0131r\u0131lmas\u0131, ba\u015f\u0131bo\u015f teller, yetersiz temas alan\u0131 ve zaman i\u00e7inde potansiyel gev\u015feme gibi zorluklar ortaya \u00e7\u0131karabilir. VIOX bu zorlu\u011fun \u00fcstesinden gelmek i\u00e7in \u00f6zel <strong>C45 Takma Pabu\u00e7<\/strong>\u00f6zellikle C45 standartlar\u0131na veya benzer tasar\u0131mlara uygun olanlar olmak \u00fczere, telli kablolar ve kelep\u00e7e tarz\u0131 terminal bloklar\u0131 aras\u0131nda temiz, sa\u011flam ve g\u00fcvenilir bir aray\u00fcz sa\u011flamak i\u00e7in \u00f6zel olarak tasarlanm\u0131\u015f, yal\u0131t\u0131ms\u0131z, pim \u015feklinde bir k\u0131vr\u0131ml\u0131 terminal t\u00fcr\u00fcd\u00fcr.<\/p>\n<p>Genellikle bir <strong>C45 pin terminali<\/strong> veya <strong>kablo ucu terminali<\/strong>Bu bile\u015fen \u00e7ok \u00f6nemli bir arac\u0131 g\u00f6revi g\u00f6r\u00fcr. \u00c7ok telli bir kablonun esnek ucunu, kat\u0131 iletkenler veya pimler i\u00e7in tasarlanm\u0131\u015f terminal bloklar\u0131na yerle\u015ftirmek i\u00e7in m\u00fckemmel \u015fekilde uygun olan kat\u0131, boyutsal olarak tutarl\u0131 bir pime d\u00f6n\u00fc\u015ft\u00fcr\u00fcr. Bu \u00fcr\u00fcn, bazen geni\u015f bir terim alt\u0131nda kategorize edilse de <strong>bak\u0131r pabu\u00e7<\/strong>saplama veya vidalara ba\u011flanan geleneksel halka veya \u00e7atal pabu\u00e7lara k\u0131yasla farkl\u0131 bir i\u015flev g\u00f6r\u00fcr.<\/p>\n<h2>C45 Takma Pabu\u00e7 Tasar\u0131m\u0131n\u0131 Anlama<\/h2>\n<p>VIOX C45 Insert-in Lug'\u0131n benzersiz tasar\u0131m\u0131 amaca y\u00f6neliktir:<\/p>\n<ul>\n<li><strong>\"C45\" Tan\u0131mlamas\u0131:<\/strong> Bu genellikle C45 DIN ray\u0131 terminal bloklar\u0131, devre kesiciler ve belirli yerle\u015ftirme yuvalar\u0131 veya s\u0131k\u0131\u015ft\u0131rma mekanizmalar\u0131 kullanan di\u011fer bile\u015fenlerle uyumlulukla ilgilidir. C45 olarak belirlenmi\u015f bir pimin kullan\u0131lmas\u0131, g\u00fcvenli bir uyum i\u00e7in boyutsal uyumluluk sa\u011flar.<\/li>\n<li><strong>\"Yerle\u015ftirme\" \u0130\u015flevselli\u011fi:<\/strong> Kat\u0131 pim ucu, do\u011frudan bir terminal blo\u011funun al\u0131c\u0131 kelep\u00e7esine (vidal\u0131 kelep\u00e7e, yayl\u0131 kelep\u00e7e, vb.) tak\u0131lmak \u00fczere tasarlanm\u0131\u015ft\u0131r.<\/li>\n<li><strong>\"Pin-Shape\":<\/strong> Sonland\u0131rma ucu, terminal blo\u011funun kelep\u00e7esi ile g\u00fcvenilir bir \u015fekilde aray\u00fcz olu\u015fturan tan\u0131mlanm\u0131\u015f bir temas y\u00fczeyi alan\u0131 sa\u011flayan kat\u0131, genellikle d\u00fczle\u015ftirilmi\u015f bir pimdir.<\/li>\n<li><strong>\"Yal\u0131t\u0131ms\u0131z\":<\/strong> Bu terminaller plastik yal\u0131t\u0131m k\u0131l\u0131flar\u0131 olmadan tedarik edilir, bu da onlar\u0131 kapal\u0131 paneller i\u00e7inde veya yal\u0131t\u0131m gereksinimlerinin terminal blo\u011funun kendisi veya genel sistem tasar\u0131m\u0131 taraf\u0131ndan kar\u015f\u0131land\u0131\u011f\u0131 yerlerde kullan\u0131m i\u00e7in uygun hale getirir.<\/li>\n<li><strong>\"S\u0131kma Terminali\":<\/strong> Arka b\u00f6l\u00fcmde, g\u00fc\u00e7l\u00fc bir mekanik ve elektriksel ba\u011f olu\u015fturacak \u015fekilde \u00e7ok telli bak\u0131r telin s\u0131yr\u0131lm\u0131\u015f ucuna kal\u0131c\u0131 olarak k\u0131vr\u0131lmak \u00fczere tasarlanm\u0131\u015f diki\u015fsiz bir namlu bulunur.<\/li>\n<li><strong>\"Bak\u0131r Kalayl\u0131\":<\/strong> Y\u00fcksek iletkenli\u011fe sahip bak\u0131rdan (\u00f6zellikle spesifikasyonlarda belirtilen T2 s\u0131n\u0131f\u0131 bak\u0131r) \u00fcretilmi\u015ftir ve m\u00fckemmel ak\u0131m ta\u015f\u0131ma kapasitesi, dayan\u0131kl\u0131l\u0131k ve korozyona kar\u015f\u0131 uzun s\u00fcreli diren\u00e7 sa\u011flayan elektro-kalay kaplama ile tamamlanm\u0131\u015ft\u0131r.<\/li>\n<\/ul>\n<h2>M\u00fchendislik Avantajlar\u0131 ve Faydalar\u0131<\/h2>\n<p>VIOX'un Kullan\u0131lmas\u0131 <strong>C45 bak\u0131r pim terminali<\/strong> elektrik montaj\u0131nda ve sistem g\u00fcvenilirli\u011finde \u00f6nemli avantajlar sunar:<\/p>\n<ul>\n<li><strong>Ba\u015f\u0131bo\u015f Telleri Ortadan Kald\u0131r\u0131r:<\/strong> T\u00fcm iletken tellerini s\u0131kma kovan\u0131 i\u00e7inde g\u00fcvenli bir \u015fekilde tutarak biti\u015fik terminaller aras\u0131nda k\u0131sa devrelere neden olabilecek ba\u015f\u0131bo\u015f telleri \u00f6nler.<\/li>\n<li><strong>G\u00fcvenilir Temas Sa\u011flar:<\/strong> Yekpare pim, terminal blo\u011fu kelep\u00e7esi i\u00e7inde tutarl\u0131, tan\u0131mlanm\u0131\u015f bir temas y\u00fczeyi alan\u0131 sa\u011flayarak, yanl\u0131\u015f sonland\u0131r\u0131lm\u0131\u015f \u00e7ok telli kabloya k\u0131yasla daha d\u00fc\u015f\u00fck temas direnci ve daha az a\u015f\u0131r\u0131 \u0131s\u0131nma riski sa\u011flar.<\/li>\n<li><strong>Kurulumu Basitle\u015ftirir:<\/strong> \u00c7ok telli kablolar\u0131n, tek telli kablolara benzer \u015fekilde klemenslere h\u0131zl\u0131 ve kolay bir \u015fekilde yerle\u015ftirilmesini sa\u011flayarak montaj s\u00fcresini h\u0131zland\u0131r\u0131r.<\/li>\n<li><strong>Ba\u011flant\u0131 G\u00fcvenli\u011fini Art\u0131r\u0131r:<\/strong> Sa\u011flam pim, klemens kelep\u00e7esinin kavramas\u0131 i\u00e7in sabit bir iletken formu sa\u011flayarak titre\u015fim veya termal d\u00f6ng\u00fc nedeniyle gev\u015feme olas\u0131l\u0131\u011f\u0131n\u0131 azalt\u0131r.<\/li>\n<li><strong>Dayan\u0131kl\u0131l\u0131\u011f\u0131 Art\u0131r\u0131r:<\/strong> Kalay kapl\u0131 bak\u0131r yap\u0131 korozyona kar\u015f\u0131 dayan\u0131kl\u0131d\u0131r ve uzun bir hizmet \u00f6mr\u00fc sa\u011flar. Diki\u015fsiz namlu sa\u011flam bir k\u0131vr\u0131ml\u0131 ba\u011flant\u0131 sa\u011flar.<\/li>\n<li><strong>Bak\u0131m\u0131 Kolayla\u015ft\u0131r\u0131r:<\/strong> Pimli pabu\u00e7larla sonland\u0131r\u0131lan kablolar, bak\u0131m veya sistem de\u011fi\u015fiklikleri s\u0131ras\u0131nda kolayca \u00e7\u0131kar\u0131labilir ve terminal bloklar\u0131na yeniden tak\u0131labilir.<\/li>\n<\/ul>\n<h2>C45 Takma Pabu\u00e7lar i\u00e7in Tipik Uygulamalar<\/h2>\n<p>E\u015fsiz \u00f6zellikleri <strong>C45 yal\u0131t\u0131ms\u0131z kablo terminali<\/strong> dahil olmak \u00fczere \u00e7e\u015fitli uygulamalarda vazge\u00e7ilmez k\u0131lmaktad\u0131r:<\/p>\n<ul>\n<li>Kontrol Kabinleri ve Pano Yap\u0131m\u0131<\/li>\n<li>DIN Ray\u0131na Monte Terminal Blo\u011fu Tertibatlar\u0131 (\u00f6zellikle C45 tipleri)<\/li>\n<li>Devre Kesici ve Kontakt\u00f6r Kablolar\u0131<\/li>\n<li>PLC (Programlanabilir Mant\u0131k Denetleyici) I\/O Kablolamas\u0131<\/li>\n<li>End\u00fcstriyel Otomasyon ve Makineler<\/li>\n<li>G\u00fc\u00e7 Da\u011f\u0131t\u0131m \u00dcniteleri<\/li>\n<li>\u00c7ok telli iletkenlerin kelep\u00e7e tipi terminallere g\u00fcvenilir ba\u011flant\u0131ya ihtiya\u00e7 duydu\u011fu her yerde.<\/li>\n<\/ul>\n<h2>Teknik \u00d6zellikler: C45 (A) &amp; C45 (B) Serisi<\/h2>\n<p>VIOX, boyutlar\u0131 veya kablo aral\u0131\u011f\u0131 uygunlu\u011fu a\u00e7\u0131s\u0131ndan biraz farkl\u0131l\u0131k g\u00f6sterebilen C45 (A) ve C45 (B) gibi tiplerde grupland\u0131r\u0131lm\u0131\u015f \u00e7e\u015fitli boyutlarda C45 Tak\u0131labilir Pabu\u00e7lar sunar. Ayr\u0131nt\u0131l\u0131 \u00f6zellikler i\u00e7in l\u00fctfen a\u015fa\u011f\u0131daki tablolara bak\u0131n:<\/p>\n<h3>C45 (A) Yerle\u015ftirme Pabucu (t\u00fcp)<\/h3>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>D \u00b10,3 (mm)<\/th>\n<th>d \u00b10,3 (mm)<\/th>\n<th>L \u00b11,5 (mm)<\/th>\n<th>L1 \u00b11 (mm)<\/th>\n<th>B \u00b10,3 (mm)<\/th>\n<th>Duvar kal\u0131nl\u0131\u011f\u0131 (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>C45-4\u1d40<\/td>\n<td>4.8<\/td>\n<td>3.2<\/td>\n<td>25<\/td>\n<td>10.0<\/td>\n<td>4.5<\/td>\n<td>0.8<\/td>\n<\/tr>\n<tr>\n<td>C45-6\u1d40<\/td>\n<td>6.0<\/td>\n<td>4.0<\/td>\n<td>27<\/td>\n<td>10.3<\/td>\n<td>4.8<\/td>\n<td>1.0<\/td>\n<\/tr>\n<tr>\n<td>C45-10\u1d40<\/td>\n<td>7.5<\/td>\n<td>5.1<\/td>\n<td>32<\/td>\n<td>12.5<\/td>\n<td>6.5<\/td>\n<td>1.2<\/td>\n<\/tr>\n<tr>\n<td>C45-16\u1d40<\/td>\n<td>8.5<\/td>\n<td>6.0<\/td>\n<td>34<\/td>\n<td>13.5<\/td>\n<td>6.8<\/td>\n<td>1.25<\/td>\n<\/tr>\n<tr>\n<td>C45-25\u1d40<\/td>\n<td>10<\/td>\n<td>7.3<\/td>\n<td>36<\/td>\n<td>14.0<\/td>\n<td>6.8<\/td>\n<td>1.35<\/td>\n<\/tr>\n<tr>\n<td>C45-35\u1d40<\/td>\n<td>11<\/td>\n<td>8.2<\/td>\n<td>38<\/td>\n<td>14.5<\/td>\n<td>6.8<\/td>\n<td>1.4<\/td>\n<\/tr>\n<tr>\n<td>C45-50\u1d40<\/td>\n<td>13<\/td>\n<td>10.0<\/td>\n<td>42<\/td>\n<td>15.0<\/td>\n<td>6.8<\/td>\n<td>1.5<\/td>\n<\/tr>\n<tr>\n<td>C45-70\u1d40<\/td>\n<td>16<\/td>\n<td>12.0<\/td>\n<td>49<\/td>\n<td>18.0<\/td>\n<td>7.0<\/td>\n<td>2.0<\/td>\n<\/tr>\n<tr>\n<td>C45-95\u1d40<\/td>\n<td>18<\/td>\n<td>14.0<\/td>\n<td>55<\/td>\n<td>20.0<\/td>\n<td>7.0<\/td>\n<td>2.0<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>C45 (B) Yerle\u015ftirme Pabucu (t\u00fcp)<\/h3>\n<table>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>D \u00b10,3 (mm)<\/th>\n<th>d \u00b10,3 (mm)<\/th>\n<th>L \u00b11,5 (mm)<\/th>\n<th>L1 \u00b11 (mm)<\/th>\n<th>B \u00b10,3 (mm)<\/th>\n<th>Duvar kal\u0131nl\u0131\u011f\u0131 (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>C45-10\u1d40<\/td>\n<td>6.5<\/td>\n<td>5.1<\/td>\n<td>32<\/td>\n<td>12.5<\/td>\n<td>6.5<\/td>\n<td>0.7<\/td>\n<\/tr>\n<tr>\n<td>C45-16\u1d40<\/td>\n<td>7.5<\/td>\n<td>5.9<\/td>\n<td>34<\/td>\n<td>13.5<\/td>\n<td>6.8<\/td>\n<td>0.8<\/td>\n<\/tr>\n<tr>\n<td>C45-25\u1d40<\/td>\n<td>9.0<\/td>\n<td>7.2<\/td>\n<td>36<\/td>\n<td>14.0<\/td>\n<td>6.8<\/td>\n<td>0.9<\/td>\n<\/tr>\n<tr>\n<td>C45-35\u1d40<\/td>\n<td>10.5<\/td>\n<td>8.5<\/td>\n<td>38<\/td>\n<td>14.5<\/td>\n<td>6.8<\/td>\n<td>1.0<\/td>\n<\/tr>\n<tr>\n<td>C45-50\u1d40<\/td>\n<td>12.5<\/td>\n<td>10.1<\/td>\n<td>42<\/td>\n<td>15.0<\/td>\n<td>6.7<\/td>\n<td>1.2<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><i>Tablo G\u00f6stergesi (referans diyagram\u0131): D: Namlu D\u0131\u015f \u00c7ap\u0131; d: \u0130letken Giri\u015fi \u0130\u00e7 \u00c7ap\u0131; L: Toplam Uzunluk; L1: Pim Uzunlu\u011fu; B: Pim Geni\u015fli\u011fi; Duvar kal\u0131nl\u0131\u011f\u0131: Namlu Malzeme Kal\u0131nl\u0131\u011f\u0131. Modeller (\u00f6rne\u011fin, C45-16\u1d40) tipik olarak terminalin tasarland\u0131\u011f\u0131 $mm^2$ cinsinden nominal iletken kesitini g\u00f6sterir. Potansiyel olarak \u00f6rt\u00fc\u015fen kablo boyutlar\u0131 i\u00e7in C45(A) ve C45(B) serileri aras\u0131ndaki farkl\u0131 boyutlara dikkat edin.<\/i><\/p>\n<h2>C43 Takma Pabu\u00e7 \u00d6l\u00e7\u00fcs\u00fc<\/h2>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-15706\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/04\/c45-insert-in-lug-dimension.webp\" alt=\"c45 insert in lug dimension\" width=\"882\" height=\"240\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/04\/c45-insert-in-lug-dimension.webp 882w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/04\/c45-insert-in-lug-dimension-300x82.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/04\/c45-insert-in-lug-dimension-768x209.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/04\/c45-insert-in-lug-dimension-18x5.webp 18w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/04\/c45-insert-in-lug-dimension-600x163.webp 600w\" sizes=\"(max-width: 882px) 100vw, 882px\" \/><\/p>\n<h2>Kurulum \u00d6nerileri<\/h2>\n<p>ile g\u00fcvenli ve g\u00fcvenilir bir ba\u011flant\u0131 elde etmek <strong>C45 ekleme pabucu<\/strong> do\u011fru kurulum gerektirir:<\/p>\n<ol>\n<li><strong>Tel S\u0131y\u0131rma:<\/strong> Kablo yal\u0131t\u0131m\u0131n\u0131 do\u011fru uzunlukta soyun, s\u0131kma i\u015fleminden sonra a\u015f\u0131r\u0131 \u00e7\u0131plak tel g\u00f6r\u00fcnmeden s\u0131kma namlusuna tam olarak yerle\u015ftirmek i\u00e7in yeterli iletkeni a\u00e7\u0131\u011fa \u00e7\u0131kar\u0131n. \u0130letken tellerini \u00e7entiklemekten ka\u00e7\u0131n\u0131n.<\/li>\n<li><strong>S\u0131kma Aleti ve Kal\u0131p Se\u00e7imi:<\/strong> \u00d6zellikle pim terminalleri veya kablo ucu y\u00fcks\u00fckleri i\u00e7in tasarlanm\u0131\u015f y\u00fcksek kaliteli bir s\u0131kma aleti kullan\u0131n. Kullan\u0131lan C45 pabucuna uygun do\u011fru kal\u0131p yuvas\u0131 boyutunu se\u00e7in. Yanl\u0131\u015f aletlerin kullan\u0131lmas\u0131 (standart halka pabu\u00e7lar i\u00e7in olanlar gibi) zay\u0131f bir k\u0131vr\u0131ma neden olabilir.<\/li>\n<li><strong>S\u0131kma Prosed\u00fcr\u00fc:<\/strong> Soyulmu\u015f kabloyu pabu\u00e7 kovan\u0131na tamamen yerle\u015ftirin. Namluyu do\u011fru kal\u0131p yuvas\u0131na yerle\u015ftirin ve alet \u00fcreticisinin talimatlar\u0131na g\u00f6re k\u0131vr\u0131m d\u00f6ng\u00fcs\u00fcn\u00fc tamamlay\u0131n. S\u0131k\u0131 ve d\u00fczg\u00fcn bir k\u0131vr\u0131m elde edildi\u011finden emin olun.<\/li>\n<li><strong>Terminal Blo\u011fu Yerle\u015ftirme:<\/strong> Terminal blo\u011fu \u00fczerindeki kelep\u00e7eyi a\u00e7\u0131n. K\u0131vr\u0131ml\u0131 C45 pimini terminal a\u00e7\u0131kl\u0131\u011f\u0131na dibe vurana veya uygun oturma derinli\u011fine ula\u015fana kadar tamamen yerle\u015ftirin.<\/li>\n<li><strong>G\u00fcvenli Kelep\u00e7e:<\/strong> Terminal blo\u011fu vidas\u0131n\u0131 s\u0131k\u0131n veya yayl\u0131 kelep\u00e7eyi tak\u0131l\u0131 pime s\u0131k\u0131ca ge\u00e7irin. Ba\u011flant\u0131n\u0131n mekanik olarak g\u00fcvenli oldu\u011funu do\u011frulay\u0131n.<\/li>\n<\/ol>\n<h2>Kaliteli C45 Pin Terminalleri i\u00e7in VIOX'a G\u00fcvenin<\/h2>\n<p>VIOX, y\u00fcksek kaliteli, g\u00fcvenilir elektrik bile\u015fenleri sa\u011flamay\u0131 taahh\u00fct eder. C45 Eklemeli Bak\u0131r Pabu\u00e7lar\u0131m\u0131z, boyutsal do\u011fruluk ve tutarl\u0131 performans sa\u011flamak i\u00e7in y\u00fcksek kaliteli T2 bak\u0131r ve hassas s\u00fcre\u00e7ler kullan\u0131larak \u00fcretilmektedir. VIOX C45 terminalleri ile, \u00e7ok telli kablo ba\u011flant\u0131lar\u0131n\u0131z\u0131n g\u00fcvenli ve uzun \u00f6m\u00fcrl\u00fc oldu\u011funu bilerek g\u00fcvenle elektrik panolar\u0131 ve sistemleri olu\u015fturabilirsiniz.<\/p>\n<p><strong>Bir sonraki projeniz i\u00e7in g\u00fcvenilir pin terminallerine mi ihtiyac\u0131n\u0131z var? C45 Insert-in Lug'lar\u0131m\u0131z hakk\u0131nda bilgi almak, numune talep etmek, fiyat teklifi almak veya hangi C45 tipinin (A veya B) \u00f6zel uygulama gereksinimlerinize en uygun oldu\u011funu tart\u0131\u015fmak i\u00e7in bug\u00fcn VIOX ile ileti\u015fime ge\u00e7in.<\/strong><\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>VIOX C45 Eklemeli Bak\u0131r Pabu\u00e7, C45 terminal bloklar\u0131ndaki \u00e7ok telli kablolar i\u00e7in g\u00fcvenilir ba\u011flant\u0131lar sa\u011flar. Kalay kapl\u0131 T2 bak\u0131rdan yap\u0131lm\u0131\u015f olan pim tasar\u0131m\u0131, telli kablolar\u0131 \u00f6nler ve temas\u0131 art\u0131r\u0131r. Kontrol panelleri ve end\u00fcstriyel otomasyon i\u00e7in idealdir, kolay kurulum ve uzun s\u00fcreli dayan\u0131kl\u0131l\u0131k sunar.<\/p>","protected":false},"featured_media":15707,"comment_status":"closed","ping_status":"closed","template":"","meta":{"inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[],"product_cat":[213],"product_tag":[],"class_list":{"0":"post-15705","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-cable-lug","7":"desktop-align-left","8":"tablet-align-left","9":"mobile-align-left","11":"first","12":"instock","13":"shipping-taxable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product\/15705","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/comments?post=15705"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/media\/15707"}],"wp:attachment":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/media?parent=15705"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product_brand?post=15705"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product_cat?post=15705"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product_tag?post=15705"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}