{"id":14304,"date":"2025-03-20T10:20:13","date_gmt":"2025-03-20T02:20:13","guid":{"rendered":"https:\/\/viox.com\/?post_type=product&#038;p=14304"},"modified":"2025-03-20T10:20:13","modified_gmt":"2025-03-20T02:20:13","slug":"viox-fct18-bgf-interval-timer-relay","status":"publish","type":"product","link":"https:\/\/test.viox.com\/tr\/urun\/viox-fct18-bgf-interval-timer-relay\/","title":{"rendered":"VIOX FCT18-BgF Kontrol Sinyali Kapal\u0131 Aral\u0131kl\u0131 Zamanlay\u0131c\u0131 R\u00f6lesi"},"content":{"rendered":"<div class=\"product-intro\">\n<h2>VIOX FCT18-BgF Aral\u0131kl\u0131 Zamanlay\u0131c\u0131 R\u00f6lesine Giri\u015f<\/h2>\n<p>VIOX FCT18-BgF, zamanlama do\u011frulu\u011fu ve g\u00fcvenilirli\u011finin kritik gereksinimler oldu\u011fu end\u00fcstriyel otomasyon sistemleri i\u00e7in tasarlanm\u0131\u015f y\u00fcksek hassasiyetli bir aral\u0131kl\u0131 zamanlay\u0131c\u0131 r\u00f6lesidir. Bu \u00e7ok y\u00f6nl\u00fc zamanlama cihaz\u0131, bir kontrol sinyali kapatma i\u015flevi (d\u00fc\u015fen kenar tetiklemeli KAPALI gecikme) ile \u00e7al\u0131\u015f\u0131r, bu da onu bir kontrol sinyali kald\u0131r\u0131ld\u0131ktan sonra proses kontrol\u00fcn\u00fcn hassas zamanlama aral\u0131klar\u0131 gerektirdi\u011fi uygulamalar i\u00e7in ideal bir se\u00e7im haline getirir.<\/p>\n<h2>Aral\u0131kl\u0131 Zamanlay\u0131c\u0131 R\u00f6lesi nedir?<\/h2>\n<p>Aral\u0131kl\u0131 zamanlay\u0131c\u0131 r\u00f6lesi, elektrik devrelerindeki zamanlama i\u015flevlerini y\u00f6neten \u00f6zel bir kontrol cihaz\u0131d\u0131r. Devreleri basit\u00e7e a\u00e7an veya kapatan standart r\u00f6lelerin aksine, zamanlay\u0131c\u0131 r\u00f6leler elektrik i\u015flemlerinin ne zaman ger\u00e7ekle\u015fece\u011fi \u00fczerinde hassas kontrol sa\u011flayan bir zamanlama eleman\u0131 sunar. FCT18-BgF \u00f6zellikle \"OFF-delay\" zamanlama fonksiyonunu kullan\u0131r, bu da kontrol sinyali kapat\u0131ld\u0131ktan sonra r\u00f6lenin \u00f6nceden belirlenmi\u015f bir s\u00fcre boyunca enerjili kalmas\u0131 anlam\u0131na gelir ve \u00e7e\u015fitli uygulamalarda kontroll\u00fc bir kapatma s\u0131ras\u0131 sa\u011flar.<\/p>\n<h2>FCT18-BgF Aral\u0131kl\u0131 Zamanlay\u0131c\u0131 R\u00f6lesinin Temel \u00d6zellikleri<\/h2>\n<h3>\u00c7ok Y\u00f6nl\u00fc Zamanlama \u0130\u015flevselli\u011fi<\/h3>\n<p>FCT18-BgF, d\u00fc\u015fen kenar tetiklemeli bir KAPALI-gecikmeli zamanlama i\u015flevine sahiptir. Bu, zamanlama d\u00f6ng\u00fcs\u00fcn\u00fcn kontrol sinyali (S) kapat\u0131ld\u0131\u011f\u0131nda ba\u015flad\u0131\u011f\u0131 ve gecikme i\u015fleminin zamanlama d\u00f6ng\u00fcs\u00fc s\u0131ras\u0131nda S giri\u015findeki sonraki de\u011fi\u015fikliklerden etkilenmedi\u011fi anlam\u0131na gelir. Bu, karma\u015f\u0131k end\u00fcstriyel ortamlarda istikrarl\u0131 ve \u00f6ng\u00f6r\u00fclebilir zamanlama i\u015flemleri sa\u011flar.<\/p>\n<h3>Ola\u011fan\u00fcst\u00fc Zaman Aral\u0131\u011f\u0131 Esnekli\u011fi<\/h3>\n<p>FCT18-BgF'nin en etkileyici y\u00f6nlerinden biri, ola\u011fan\u00fcst\u00fc geni\u015f zaman aral\u0131\u011f\u0131 kapasitesidir:<\/p>\n<ul>\n<li>0,1 saniyeden ba\u015flayan ultra k\u0131sa aral\u0131klar<\/li>\n<li>100 g\u00fcne kadar uzat\u0131lm\u0131\u015f s\u00fcreler<\/li>\n<\/ul>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-14306\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-BgF-Interval-Relay-with-Control-Signal-Off-time-range.webp\" alt=\"VIOX FCT18-BgF Interval Relay with Control Signal Off time range\" width=\"834\" height=\"322\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-BgF-Interval-Relay-with-Control-Signal-Off-time-range.webp 834w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-BgF-Interval-Relay-with-Control-Signal-Off-time-range-300x116.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-BgF-Interval-Relay-with-Control-Signal-Off-time-range-768x297.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-BgF-Interval-Relay-with-Control-Signal-Off-time-range-18x7.webp 18w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-BgF-Interval-Relay-with-Control-Signal-Off-time-range-600x232.webp 600w\" sizes=\"(max-width: 834px) 100vw, 834px\" \/><\/p>\n<p>Bu ola\u011fan\u00fcst\u00fc aral\u0131k, se\u00e7ilebilir on zaman ayar\u0131na g\u00f6re d\u00fczenlenmi\u015ftir:<\/p>\n<ul>\n<li>0.1-1s<\/li>\n<li>1-10s<\/li>\n<li>0.1-1m<\/li>\n<li>1-10m<\/li>\n<li>0.1-1 saat<\/li>\n<li>1-10 saat<\/li>\n<li>0.1-1g\u00fcn<\/li>\n<li>1-10 g\u00fcn<\/li>\n<li>3-30 g\u00fcn<\/li>\n<li>10-100 g\u00fcn<\/li>\n<\/ul>\n<h3>Hassas Oran Kontrol\u00fc<\/h3>\n<p>FCT18-BgF, oran ayar\u0131 \u00f6zelli\u011fi sayesinde zamanlama \u00fczerinde gran\u00fcler kontrol sunar. Oran, se\u00e7ilen zaman aral\u0131\u011f\u0131n\u0131n 10%'den 100%'ye kadar art\u0131\u015flarla ayarlanabilir:<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-14307\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-BgF-Interval-Relay-with-Control-Signal-Off-ratio-setting.webp\" alt=\"VIOX FCT18-BgF Interval Relay with Control Signal Off ratio setting\" width=\"958\" height=\"256\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-BgF-Interval-Relay-with-Control-Signal-Off-ratio-setting.webp 958w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-BgF-Interval-Relay-with-Control-Signal-Off-ratio-setting-300x80.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-BgF-Interval-Relay-with-Control-Signal-Off-ratio-setting-768x205.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-BgF-Interval-Relay-with-Control-Signal-Off-ratio-setting-18x5.webp 18w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-BgF-Interval-Relay-with-Control-Signal-Off-ratio-setting-600x160.webp 600w\" sizes=\"(max-width: 958px) 100vw, 958px\" \/><br \/>\n10%, 15%, 20%, 25%, 30%, 35%, 40%, 45%, 50%, 55%, 60%, 65%, 70%, 75%, 80%, 85%, 90%, 95% ve 100%<\/p>\n<p>Bu, belirli uygulama gereksinimlerini kar\u015f\u0131lamak i\u00e7in zamanlama aral\u0131klar\u0131n\u0131n hassas bir \u015fekilde \u00f6zelle\u015ftirilmesine olanak tan\u0131r.<\/p>\n<h3>Evrensel G\u00fc\u00e7 Kayna\u011f\u0131 Uyumlulu\u011fu<\/h3>\n<p>FCT18-BgF, 12 ila 240 VAC\/DC aras\u0131nda geni\u015f bir g\u00fc\u00e7 kayna\u011f\u0131 aral\u0131\u011f\u0131na sahip olacak \u015fekilde esneklik d\u00fc\u015f\u00fcn\u00fclerek tasarlanm\u0131\u015ft\u0131r. Bu evrensel uyumluluk, birden fazla r\u00f6le \u00e7e\u015fidine olan ihtiyac\u0131 ortadan kald\u0131r\u0131r ve bak\u0131m ekipleri i\u00e7in envanter y\u00f6netimini basitle\u015ftirir.<\/p>\n<h3>\u00dcst\u00fcn Zamanlama Do\u011frulu\u011fu<\/h3>\n<p>FCT18-BgF, 0,5%'den daha az zaman hatas\u0131 ve sadece 0,1% zaman sapmas\u0131 ile kritik zamanlama uygulamalar\u0131 i\u00e7in ola\u011fan\u00fcst\u00fc hassasiyet sunar. R\u00f6le ayr\u0131ca 0,5% tekrarlama do\u011frulu\u011funu koruyarak birden fazla i\u015flemde tutarl\u0131 performans sa\u011flar.<\/p>\n<h3>Sa\u011flam \u00c7evresel Performans<\/h3>\n<p>End\u00fcstriyel ortamlar i\u00e7in tasarlanan FCT18-BgF, -20\u00b0C ila +60\u00b0C (-40\u00b0F ila +85\u00b0F) aras\u0131ndaki geni\u015f bir s\u0131cakl\u0131k aral\u0131\u011f\u0131nda g\u00fcvenilir bir \u015fekilde \u00e7al\u0131\u015f\u0131r. 20\u00b0C'de 0,05%\/\u00b0C (68\u00b0F'de 0,05%\/\u00b0F) s\u0131cakl\u0131k katsay\u0131s\u0131, de\u011fi\u015fken ortam ko\u015fullar\u0131nda bile zamanlama kararl\u0131l\u0131\u011f\u0131 sa\u011flar.<\/p>\n<h3>G\u00fc\u00e7l\u00fc Anti-Parazit Yetene\u011fi<\/h3>\n<p>End\u00fcstriyel ortamlar genellikle hassas kontrol ekipmanlar\u0131n\u0131n performans\u0131n\u0131 etkileyebilecek elektriksel g\u00fcr\u00fclt\u00fc ve parazit i\u00e7erir. FCT18-BgF, elektriksel olarak g\u00fcr\u00fclt\u00fcl\u00fc ortamlarda bile g\u00fcvenilir \u00e7al\u0131\u015fma sa\u011flayan g\u00fc\u00e7l\u00fc parazit \u00f6nleme \u00f6zelliklerine sahiptir.<\/p>\n<h2>Teknik \u00d6zellikler<\/h2>\n<h3>Mevcut Modeller<\/h3>\n<p>FCT18-BgF'nin iki \u00e7e\u015fidi bulunmaktad\u0131r:<\/p>\n<ul>\n<li><strong>FCT18-BgF1<\/strong>: 16A de\u011ferinde 1 SPDT (Tek Kutuplu \u00c7ift At\u0131\u015fl\u0131) kontak i\u00e7erir<\/li>\n<li><strong>FCT18-BgF2<\/strong>: 16A de\u011ferinde 2 SPDT kontak i\u00e7erir<\/li>\n<\/ul>\n<h3>Model Kodlama Sistemi<\/h3>\n<p>FCT18-BgF, sipari\u015f spesifikasyonu i\u00e7in a\u00e7\u0131k bir kodlama sistemi izler:<br \/>\n<strong>FCT18-BgF 1 W N<\/strong><\/p>\n<p>Nerede?<\/p>\n<ol>\n<li><strong>Fonksiyon<\/strong>: BgF (KAPALI-gecikme)<\/li>\n<li><strong>\u00c7\u0131kt\u0131 t\u00fcr\u00fc<\/strong>: 1 (1CO konta\u011f\u0131) veya 2 (2CO konta\u011f\u0131)<\/li>\n<li><strong>Besleme gerilimi<\/strong>: A (AC230V), D (DC24V) veya W (AC\/DC12-240V)<\/li>\n<li><strong>Kontrol sinyali<\/strong>: N (NPN) veya P (PNP)<\/li>\n<\/ol>\n<h3>Elektriksel \u00d6zellikler<\/h3>\n<table>\n<tbody>\n<tr>\n<th>Parametre<\/th>\n<th>\u015eartname<\/th>\n<\/tr>\n<tr>\n<td>Giri\u015f Terminali<\/td>\n<td>A1-A2<\/td>\n<\/tr>\n<tr>\n<td>Gerilim aral\u0131\u011f\u0131<\/td>\n<td>AC 230V \/ DC24V \/ AC\/DC 12-240V<\/td>\n<\/tr>\n<tr>\n<td>G\u00fc\u00e7 t\u00fcketimi<\/td>\n<td>AC 3.5VA\/ DC 2.0W<\/td>\n<\/tr>\n<tr>\n<td>Gerilim tolerans\u0131<\/td>\n<td>-15% ~ +10%<\/td>\n<\/tr>\n<tr>\n<td>Besleme g\u00f6stergesi<\/td>\n<td>Ye\u015fil LED<\/td>\n<\/tr>\n<tr>\n<td>R\u00f6le g\u00f6stergesi<\/td>\n<td>K\u0131rm\u0131z\u0131 LED<\/td>\n<\/tr>\n<tr>\n<td>Zaman aral\u0131klar\u0131<\/td>\n<td>0.1s-100days<\/td>\n<\/tr>\n<tr>\n<td>Zaman ayar\u0131<\/td>\n<td>D\u00fc\u011fme<\/td>\n<\/tr>\n<tr>\n<td>Zaman sapmas\u0131<\/td>\n<td>0.1%<\/td>\n<\/tr>\n<tr>\n<td>Tekrarlama do\u011frulu\u011fu<\/td>\n<td>0.5%<\/td>\n<\/tr>\n<tr>\n<td>S\u0131cakl\u0131k katsay\u0131s\u0131<\/td>\n<td>0,05%\/\u00b0C, 20\u00b0C'de (0,05%\/\u00b0F, 68\u00b0F'de)<\/td>\n<\/tr>\n<tr>\n<td>\u00c7\u0131k\u0131\u015f konta\u011f\u0131<\/td>\n<td>1*SPDT (FCT18-BgF1) veya 2*SPDT (FCT18-BgF2)<\/td>\n<\/tr>\n<tr>\n<td>Nominal ak\u0131m<\/td>\n<td>1*16A (FCT18-BgF1) veya 2*16A (FCT18-BgF2)<\/td>\n<\/tr>\n<tr>\n<td>Mekanik \u00f6m\u00fcr<\/td>\n<td>1*10\u2077<\/td>\n<\/tr>\n<tr>\n<td>Elektriksel \u00f6m\u00fcr<\/td>\n<td>1*10\u2075<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Fiziksel \u00d6zellikler<\/h3>\n<table>\n<tbody>\n<tr>\n<th>Parametre<\/th>\n<th>\u015eartname<\/th>\n<\/tr>\n<tr>\n<td>Ortam S\u0131cakl\u0131\u011f\u0131<\/td>\n<td>-20 ... +60\u00b0C \/ -40 ... +85\u00b0F<\/td>\n<\/tr>\n<tr>\n<td>Montaj<\/td>\n<td>DIN ray\u0131 EN\/IEC 60715<\/td>\n<\/tr>\n<tr>\n<td>IP Derecesi<\/td>\n<td>IP20<\/td>\n<\/tr>\n<tr>\n<td>S\u0131y\u0131rma uzunlu\u011fu<\/td>\n<td>7 mm (0,28 in\u00e7)<\/td>\n<\/tr>\n<tr>\n<td>Kurulu y\u00fckseklik<\/td>\n<td>\u22642200m<\/td>\n<\/tr>\n<tr>\n<td>Kirlilik seviyesi<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td>Maksimum kablo boyutu<\/td>\n<td>AWG13-20 0,4N-m<\/td>\n<\/tr>\n<tr>\n<td>Boyut<\/td>\n<td>90mm*18mm*64mm<\/td>\n<\/tr>\n<tr>\n<td>A\u011f\u0131rl\u0131k<\/td>\n<td>yakla\u015f\u0131k 90g<\/td>\n<\/tr>\n<tr>\n<td>Standartlar<\/td>\n<td>GB\/T 14048.5, IEC60947-5-1, EN6812-1<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Kablolama Se\u00e7enekleri<\/h2>\n<p>FCT18-BgF hem NPN hem de PNP kontrol sinyali konfig\u00fcrasyonlar\u0131n\u0131 destekler:<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-14308\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-BgF-Interval-Relay-with-Control-Signal-Off-wiring.webp\" alt=\"VIOX FCT18-BgF Interval Relay with Control Signal Off wiring\" width=\"398\" height=\"386\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-BgF-Interval-Relay-with-Control-Signal-Off-wiring.webp 398w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-BgF-Interval-Relay-with-Control-Signal-Off-wiring-300x291.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-BgF-Interval-Relay-with-Control-Signal-Off-wiring-12x12.webp 12w\" sizes=\"(max-width: 398px) 100vw, 398px\" \/><\/p>\n<h3>NPN Konfig\u00fcrasyonu<\/h3>\n<ul>\n<li>A1 terminali: DC+\/AC L<\/li>\n<li>S terminali: Kontrol sinyali giri\u015fi<\/li>\n<li>A2 terminali: DC-\/AC N<\/li>\n<\/ul>\n<h3>PNP Konfig\u00fcrasyonu<\/h3>\n<ul>\n<li>A1 terminali: DC+\/AC L<\/li>\n<li>S terminali: Kontrol sinyali giri\u015fi<\/li>\n<li>A2 terminali: DC-\/AC N<\/li>\n<\/ul>\n<h2>Zamanlama Fonksiyonu \u00c7al\u0131\u015fmas\u0131<\/h2>\n<p>FCT18-BgF bir KAPALI-gecikme zamanlama fonksiyonu ile \u00e7al\u0131\u015f\u0131r:<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-14305\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-BgF-Interval-Relay-with-Control-Signal-Off-timing-function.webp\" alt=\"VIOX FCT18-BgF Interval Relay with Control Signal Off timing function\" width=\"846\" height=\"266\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-BgF-Interval-Relay-with-Control-Signal-Off-timing-function.webp 846w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-BgF-Interval-Relay-with-Control-Signal-Off-timing-function-300x94.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-BgF-Interval-Relay-with-Control-Signal-Off-timing-function-768x241.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-BgF-Interval-Relay-with-Control-Signal-Off-timing-function-18x6.webp 18w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-BgF-Interval-Relay-with-Control-Signal-Off-timing-function-600x189.webp 600w\" sizes=\"(max-width: 846px) 100vw, 846px\" \/><\/p>\n<ol>\n<li>G\u00fc\u00e7 (Un) uyguland\u0131\u011f\u0131nda, r\u00f6le bekleme modunda kal\u0131r<\/li>\n<li>Kontrol sinyali (S) etkinle\u015ftirildi\u011finde, r\u00f6leye (R) hemen enerji verilir<\/li>\n<li>Kontrol sinyali (S) kapat\u0131ld\u0131\u011f\u0131nda (d\u00fc\u015fen kenar), r\u00f6le enerjili kal\u0131r<\/li>\n<li>R\u00f6le programlanm\u0131\u015f zaman gecikmesine (T) ba\u015flar<\/li>\n<li>Zaman gecikmesi sona erdi\u011finde, r\u00f6lenin enerjisi kesilir<\/li>\n<li>Gecikme i\u015flemi, zamanlama s\u0131ras\u0131nda S giri\u015findeki de\u011fi\u015fikliklerden etkilenmez<\/li>\n<\/ol>\n<p>Bu zamanlama i\u015flevi, bir kontrol sinyali kald\u0131r\u0131ld\u0131ktan sonra bir s\u00fcrecin belirli bir s\u00fcre devam etmesi gereken uygulamalarda \u00f6zellikle yararl\u0131d\u0131r.<\/p>\n<h2>Boyut<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-14309\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-BgF-Interval-Relay-with-Control-Signal-Off-dimension.webp\" alt=\"VIOX FCT18-BgF Interval Relay with Control Signal Off dimension\" width=\"408\" height=\"372\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-BgF-Interval-Relay-with-Control-Signal-Off-dimension.webp 408w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-BgF-Interval-Relay-with-Control-Signal-Off-dimension-300x274.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-BgF-Interval-Relay-with-Control-Signal-Off-dimension-13x12.webp 13w\" sizes=\"(max-width: 408px) 100vw, 408px\" \/><\/p>\n<h2>FCT18-BgF Aral\u0131kl\u0131 Zamanlay\u0131c\u0131 R\u00f6le Uygulamalar\u0131<\/h2>\n<p>\u00c7ok y\u00f6nl\u00fc FCT18-BgF zaman r\u00f6lesi, \u00e7ok \u00e7e\u015fitli end\u00fcstriyel ve ticari uygulamalar i\u00e7in uygundur:<\/p>\n<h3>End\u00fcstriyel Otomasyon<\/h3>\n<ul>\n<li>Konvey\u00f6r bant kontrol sistemleri<\/li>\n<li>Tak\u0131m tezgah\u0131 operasyon s\u0131ralamas\u0131<\/li>\n<li>\u00dcretimde s\u00fcre\u00e7 kontrol\u00fc<\/li>\n<li>End\u00fcstriyel f\u0131r\u0131n ve ocak kontrol\u00fc<\/li>\n<li>Otomatik dolum ve paketleme sistemleri<\/li>\n<\/ul>\n<h3>HVAC Sistemleri<\/h3>\n<ul>\n<li>Fan kontrol\u00fc ve havaland\u0131rma zamanlamas\u0131<\/li>\n<li>Is\u0131tma sistemi d\u00f6ng\u00fcs\u00fc<\/li>\n<li>So\u011futma sistemi y\u00f6netimi<\/li>\n<li>Klima santrali s\u0131ralamas\u0131<\/li>\n<\/ul>\n<h3>Su Y\u00f6netimi<\/h3>\n<ul>\n<li>Pompa kontrol ve sulama sistemleri<\/li>\n<li>Su ar\u0131tma s\u00fcreci zamanlamas\u0131<\/li>\n<li>Filtrasyon sistemi kontrol\u00fc<\/li>\n<li>Seviye kontrol uygulamalar\u0131<\/li>\n<\/ul>\n<h3>Ayd\u0131nlatma Kontrol\u00fc<\/h3>\n<ul>\n<li>Ticari ayd\u0131nlatma dizileri<\/li>\n<li>G\u00fcvenlik ayd\u0131nlatma sistemleri<\/li>\n<li>Zaman ayarl\u0131 ayd\u0131nlatma kontrol\u00fc<\/li>\n<li>Enerji tasarruflu ayd\u0131nlatma uygulamalar\u0131<\/li>\n<\/ul>\n<h3>G\u00fcvenlik Sistemleri<\/h3>\n<ul>\n<li>Eri\u015fim kontrol\u00fc zamanlamas\u0131<\/li>\n<li>Alarm sistemi entegrasyonu<\/li>\n<li>Kap\u0131 kilidi kontrol dizileri<\/li>\n<li>G\u00f6zetim sistemi entegrasyonu<\/li>\n<\/ul>\n<h2>Kurulum ve Ayarlama<\/h2>\n<p>FCT18-BgF kolay kurulum ve ayarlama i\u00e7in tasarlanm\u0131\u015ft\u0131r:<\/p>\n<ol>\n<li>Cihaz\u0131 standart bir DIN ray\u0131na monte edin (EN\/IEC 60715)<\/li>\n<li>G\u00fc\u00e7 kayna\u011f\u0131n\u0131 A1 ve A2 terminallerine ba\u011flay\u0131n<\/li>\n<li>Kontrol sinyalini S terminaline ba\u011flay\u0131n<\/li>\n<li>\u00c7\u0131k\u0131\u015f kontaklar\u0131n\u0131 uygulama gereksinimlerine g\u00f6re ba\u011flay\u0131n<\/li>\n<li>Zaman ayar\u0131 se\u00e7icisini kullanarak istenen zaman aral\u0131\u011f\u0131n\u0131 ayarlay\u0131n<\/li>\n<li>Zamanlama aral\u0131\u011f\u0131na ince ayar yapmak i\u00e7in oran ayar\u0131n\u0131 yap\u0131n<\/li>\n<li>LED g\u00f6stergelerini kullanarak do\u011fru kurulumu do\u011frulay\u0131n (g\u00fc\u00e7 i\u00e7in ye\u015fil, r\u00f6le durumu i\u00e7in k\u0131rm\u0131z\u0131)<\/li>\n<\/ol>\n<h2>VIOX FCT18-BgF'nin Standart Zamanlay\u0131c\u0131 R\u00f6lelere G\u00f6re Avantajlar\u0131<\/h2>\n<h3>Geni\u015fletilmi\u015f Zaman Aral\u0131\u011f\u0131<\/h3>\n<p>Bir\u00e7ok zamanlay\u0131c\u0131 r\u00f6lesi s\u0131n\u0131rl\u0131 zamanlama aral\u0131klar\u0131 sunarken, FCT18-BgF'nin 0,1 saniyeden 100 g\u00fcne kadar olan kapasitesi neredeyse t\u00fcm zamanlama uygulamalar\u0131 i\u00e7in ola\u011fan\u00fcst\u00fc esneklik sa\u011flar.<\/p>\n<h3>Evrensel G\u00fc\u00e7 Kayna\u011f\u0131<\/h3>\n<p>Geni\u015f 12-240 VAC\/DC \u00e7al\u0131\u015fma aral\u0131\u011f\u0131, birden fazla r\u00f6le \u00e7e\u015fidine olan ihtiyac\u0131 ortadan kald\u0131rarak envanteri basitle\u015ftirir ve kurulum esnekli\u011fini art\u0131r\u0131r.<\/p>\n<h3>\u00dcst\u00fcn Do\u011fruluk<\/h3>\n<p>0,5%'den daha az zaman hatas\u0131 ile FCT18-BgF, do\u011frulu\u011fun \u00f6nemli oldu\u011fu kritik uygulamalar i\u00e7in hassas zamanlama sa\u011flar.<\/p>\n<h3>Parazit \u00d6nleyici Tasar\u0131m<\/h3>\n<p>G\u00fc\u00e7l\u00fc parazit \u00f6nleme \u00f6zelli\u011fi, elektriksel olarak g\u00fcr\u00fclt\u00fcl\u00fc end\u00fcstriyel ortamlarda bile g\u00fcvenilir \u00e7al\u0131\u015fma sa\u011flar.<\/p>\n<h3>Kompakt DIN Ray Tasar\u0131m\u0131<\/h3>\n<p>Sadece 90mm\u00d718mm\u00d764mm boyutlar\u0131ndaki FCT18-BgF, tam i\u015flevselli\u011fi korurken yerden tasarruf sa\u011flayan kurulum sunar.<\/p>\n<h3>Net G\u00f6rsel G\u00f6stergeler<\/h3>\n<p>\u0130kili LED sistemi, g\u00fcc\u00fc g\u00f6steren ye\u015fil LED ve r\u00f6le durumunu g\u00f6steren k\u0131rm\u0131z\u0131 LED ile anl\u0131k durum bilgisi sa\u011flar.<\/p>\n<h2>\u00d6nerilen Bak\u0131m ve Koruma<\/h2>\n<p>FCT18-BgF zamanlay\u0131c\u0131 r\u00f6lesinin uzun vadeli g\u00fcvenilirli\u011fini sa\u011flamak i\u00e7in:<\/p>\n<ol>\n<li>Belirtilen s\u0131cakl\u0131k aral\u0131\u011f\u0131nda temiz ve kuru bir ortamda kurun<\/li>\n<li>Cihaz\u0131n etraf\u0131nda uygun havaland\u0131rma oldu\u011fundan emin olun<\/li>\n<li>Elektrik ba\u011flant\u0131lar\u0131n\u0131n s\u0131k\u0131l\u0131\u011f\u0131n\u0131 periyodik olarak kontrol edin<\/li>\n<li>Rutin i\u015flevsel testler arac\u0131l\u0131\u011f\u0131yla do\u011fru \u00e7al\u0131\u015fmay\u0131 do\u011frulay\u0131n<\/li>\n<li>Cihaz\u0131 tozdan ve kirletici maddelerden uzak tutun<\/li>\n<li>A\u015f\u0131r\u0131 \u0131s\u0131 veya elektromanyetik parazit kaynaklar\u0131n\u0131n yak\u0131n\u0131na kurulumdan ka\u00e7\u0131n\u0131n<\/li>\n<li>Montaj ve kablolama ile ilgili belirtilen kurulum prosed\u00fcrlerini izleyin<\/li>\n<\/ol>\n<h2>Uyumluluk ve Belgelendirme<\/h2>\n<p>FCT18-BgF, a\u015fa\u011f\u0131dakiler de dahil olmak \u00fczere uluslararas\u0131 standartlara uygundur:<\/p>\n<ul>\n<li>GB\/T 14048.5<\/li>\n<li>IEC60947-5-1<\/li>\n<li>EN6812-1<\/li>\n<\/ul>\n<p>Bu sertifikalar, cihaz\u0131n end\u00fcstriyel kontrol ekipmanlar\u0131na y\u00f6nelik zorlu kalite ve g\u00fcvenlik standartlar\u0131n\u0131 kar\u015f\u0131lamas\u0131n\u0131 sa\u011flar.<\/p>\n<h2>Sonu\u00e7: Neden VIOX FCT18-BgF Aral\u0131kl\u0131 Zamanlay\u0131c\u0131 R\u00f6lesini Se\u00e7melisiniz?<\/h2>\n<p>FCT18-BgF aral\u0131kl\u0131 zamanlay\u0131c\u0131 r\u00f6lesi, VIOX'un end\u00fcstriyel uygulamalar i\u00e7in y\u00fcksek kaliteli, g\u00fcvenilir zamanlama \u00e7\u00f6z\u00fcmleri sa\u011flama taahh\u00fcd\u00fcn\u00fc temsil eder. Ola\u011fan\u00fcst\u00fc zaman aral\u0131\u011f\u0131 esnekli\u011fi, \u00fcst\u00fcn do\u011frulu\u011fu ve sa\u011flam tasar\u0131m\u0131 ile bu zamanlay\u0131c\u0131 r\u00f6le, zorlu ortamlarda tutarl\u0131 performans sunar.<\/p>\n<p>Zamanlama uygulamalar\u0131n\u0131z i\u00e7in FCT18-BgF'yi se\u00e7menizin temel nedenleri \u015funlard\u0131r:<\/p>\n<ul>\n<li>Ola\u011fan\u00fcst\u00fc zamanlama aral\u0131\u011f\u0131 0,1 saniyeden 100 g\u00fcne kadar<\/li>\n<li>Evrensel g\u00fc\u00e7 kayna\u011f\u0131 uyumlulu\u011fu (12-240 VAC\/DC)<\/li>\n<li>0,5%'den daha az zaman hatas\u0131 ile y\u00fcksek hassasiyet<\/li>\n<li>G\u00fcvenilir \u00e7al\u0131\u015fma i\u00e7in g\u00fc\u00e7l\u00fc anti-parazit \u00f6zelli\u011fi<\/li>\n<li>Net g\u00f6rsel g\u00f6stergeler ile kolay kurulum<\/li>\n<li>Kompakt DIN ray\u0131 montaj tasar\u0131m\u0131<\/li>\n<li>Uluslararas\u0131 standartlara uygunluk<\/li>\n<\/ul>\n<p>End\u00fcstriyel otomasyon, HVAC kontrol\u00fc, g\u00fcvenlik sistemleri veya hassas zamanlama kontrol\u00fc gerektiren herhangi bir uygulama i\u00e7in VIOX FCT18-BgF, modern kontrol sistemlerinin taleplerini kar\u015f\u0131layan g\u00fcvenilir ve esnek bir \u00e7\u00f6z\u00fcm sunar.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<div class=\"markdown\">\n<p>VIOX FCT18-BgF Aral\u0131kl\u0131 Zamanlay\u0131c\u0131 R\u00f6lesi, kontrol sinyalinin kald\u0131r\u0131lmas\u0131yla tetiklenen hassas KAPALI gecikme zamanlamas\u0131 (0,1s-100 g\u00fcn) sunar. &lt;0,5% hata, NPN\/PNP kontrol\u00fc, 1\/2 SPDT kontaklar, DIN ray montaj\u0131 ve AC\/DC 12-240V \u00f6zelliklerine sahiptir. Kontroll\u00fc kapatma dizilerine ihtiya\u00e7 duyan end\u00fcstriyel otomasyon i\u00e7in idealdir.<\/p>\n<\/div>\n<div class=\"MessageFooter-cvwndn leDsBF\">\n<div class=\"MessageMetadata-claACb fcypgW message-tokens has-metrics\"><\/div>\n<\/div>","protected":false},"featured_media":14310,"comment_status":"closed","ping_status":"closed","template":"","meta":{"inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[],"product_cat":[123,196],"product_tag":[],"class_list":{"0":"post-14304","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-relay","7":"product_cat-time-relay","8":"desktop-align-left","9":"tablet-align-left","10":"mobile-align-left","12":"first","13":"instock","14":"shipping-taxable","15":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product\/14304","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/comments?post=14304"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/media\/14310"}],"wp:attachment":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/media?parent=14304"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product_brand?post=14304"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product_cat?post=14304"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product_tag?post=14304"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}