{"id":14176,"date":"2025-03-19T20:05:11","date_gmt":"2025-03-19T12:05:11","guid":{"rendered":"https:\/\/viox.com\/?post_type=product&#038;p=14176"},"modified":"2025-03-19T20:08:18","modified_gmt":"2025-03-19T12:08:18","slug":"viox-fct18-b-bt-off-delay-timer-relay","status":"publish","type":"product","link":"https:\/\/test.viox.com\/tr\/urun\/viox-fct18-b-bt-off-delay-timer-relay\/","title":{"rendered":"VIOX FCT18-B\/Bt Yeniden Tetikleme Kontrol Sinyalli Kapal\u0131 Gecikmeli Zamanlay\u0131c\u0131 R\u00f6lesi"},"content":{"rendered":"<div class=\"product-intro\">\n<h2>Giri\u015f<\/h2>\n<p>VIOX FCT18-B\/Bt, end\u00fcstriyel ortamlardaki hassas zamanlama uygulamalar\u0131 i\u00e7in tasarlanm\u0131\u015f, yeniden tetikleme kontrol sinyaline sahip y\u00fcksek performansl\u0131 bir aral\u0131k r\u00f6lesidir. Profesyonel s\u0131n\u0131f bir gecikme d\u0131\u015f\u0131 zamanlay\u0131c\u0131 r\u00f6lesi olarak, \u00e7e\u015fitli end\u00fcstrilerdeki makine, ekipman ve otomatik s\u00fcre\u00e7leri kontrol etmek i\u00e7in ola\u011fan\u00fcst\u00fc g\u00fcvenilirlik, do\u011fruluk ve \u00e7ok y\u00f6nl\u00fcl\u00fck sunar.<\/p>\n<h2>Kapal\u0131 Gecikmeli Zamanlay\u0131c\u0131 R\u00f6leleri Nedir?<\/h2>\n<p>Zamanlay\u0131c\u0131 r\u00f6leler, end\u00fcstriyel kontrol sistemlerinde basit, g\u00fcvenilir ve ekonomik zamanlama \u00e7\u00f6z\u00fcmleri sa\u011flayan temel bile\u015fenlerdir. \u00d6zellikle off-delay zamanlay\u0131c\u0131 r\u00f6lesi, giri\u015f sinyali s\u0131ras\u0131nda \u00e7\u0131k\u0131\u015f\u0131n\u0131 korur ve giri\u015f sinyali durduktan sonra \u00f6nceden belirlenmi\u015f bir s\u00fcre boyunca devam eder. Bu i\u015flevsellik, kontroll\u00fc kapatma dizileri, so\u011futma s\u00fcreleri veya tetikleme olaylar\u0131ndan sonra \u00e7al\u0131\u015fmaya devam etmeyi gerektiren uygulamalar i\u00e7in \u00e7ok \u00f6nemlidir.<\/p>\n<h3>Kapal\u0131 Gecikmeli Zamanlay\u0131c\u0131 R\u00f6lelerinin Temel Faydalar\u0131<\/h3>\n<ul>\n<li><strong>Kontroll\u00fc Kapatma<\/strong>: Ekipman\u0131n g\u00fcvenli bir \u015fekilde ve do\u011fru s\u0131rayla kapanmas\u0131n\u0131 sa\u011flar<\/li>\n<li><strong>Geni\u015fletilmi\u015f \u00c7al\u0131\u015fma<\/strong>: \u0130lk sinyal sona erdikten sonra bile\u015fenlere giden g\u00fcc\u00fc korur<\/li>\n<li><strong>S\u00fcre\u00e7 Zamanlamas\u0131<\/strong>: Kritik end\u00fcstriyel s\u00fcre\u00e7ler i\u00e7in hassas zamanlama aral\u0131klar\u0131 sa\u011flar<\/li>\n<li><strong>Ekipman Korumas\u0131<\/strong>: Ani g\u00fc\u00e7 kesintilerinden kaynaklanan hasar\u0131 \u00f6nler<\/li>\n<\/ul>\n<h2>VIOX FCT18-B\/Bt Serisi \u00d6zellikleri<\/h2>\n<p>FCT18-B\/Bt serisi, VIOX'un ola\u011fan\u00fcst\u00fc performans \u00f6zelliklerine sahip y\u00fcksek kaliteli zamanlama \u00e7\u00f6z\u00fcmleri sunma taahh\u00fcd\u00fcn\u00fc temsil eder:<\/p>\n<h3>\u00c7ok Y\u00f6nl\u00fc Zamanlama Fonksiyonlar\u0131<\/h3>\n<p>FCT18-B\/Bt iki farkl\u0131 zamanlama modu sunar:<\/p>\n<ol>\n<li><strong>B: KAPALI-gecikme<\/strong> - Tetikleme sinyali sona erdikten sonra \u00e7\u0131k\u0131\u015f\u0131 \u00f6nceden ayarlanm\u0131\u015f bir s\u00fcre boyunca koruyan standart kapal\u0131 gecikme i\u015flevi<\/li>\n<li><strong>Bt: KAPALI-gecikme + anl\u0131k<\/strong> - Kapal\u0131 gecikme i\u015flevselli\u011fini anl\u0131k \u00e7\u0131k\u0131\u015f kontaklar\u0131 ile birle\u015ftirir<\/li>\n<\/ol>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-14177\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-B_Bt-Off-Delay-Timer-Relay-with-Retrigger-Control-Signal-Timing-Functions.webp\" alt=\"VIOX FCT18-B_Bt Off-Delay Timer Relay with Retrigger Control Signal Timing Functions\" width=\"590\" height=\"360\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-B_Bt-Off-Delay-Timer-Relay-with-Retrigger-Control-Signal-Timing-Functions.webp 590w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-B_Bt-Off-Delay-Timer-Relay-with-Retrigger-Control-Signal-Timing-Functions-300x183.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-B_Bt-Off-Delay-Timer-Relay-with-Retrigger-Control-Signal-Timing-Functions-18x12.webp 18w\" sizes=\"(max-width: 590px) 100vw, 590px\" \/><\/p>\n<h3>Ola\u011fan\u00fcst\u00fc Zaman Aral\u0131\u011f\u0131 Esnekli\u011fi<\/h3>\n<p>FCT18-B\/Bt, 0,1 saniye ile 100 g\u00fcn aras\u0131nda de\u011fi\u015fen zaman ayarlar\u0131yla neredeyse t\u00fcm end\u00fcstriyel zamanlama gereksinimlerini kar\u015f\u0131layabilir:<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-14178\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-B_Bt-Off-Delay-Timer-Relay-with-Retrigger-Control-Signal-Time-range.webp\" alt=\"VIOX FCT18-B_Bt Off-Delay Timer Relay with Retrigger Control Signal Time range\" width=\"662\" height=\"224\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-B_Bt-Off-Delay-Timer-Relay-with-Retrigger-Control-Signal-Time-range.webp 662w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-B_Bt-Off-Delay-Timer-Relay-with-Retrigger-Control-Signal-Time-range-300x102.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-B_Bt-Off-Delay-Timer-Relay-with-Retrigger-Control-Signal-Time-range-18x6.webp 18w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-B_Bt-Off-Delay-Timer-Relay-with-Retrigger-Control-Signal-Time-range-600x203.webp 600w\" sizes=\"(max-width: 662px) 100vw, 662px\" \/><\/p>\n<ul>\n<li>0.1-1s: Hassas k\u0131sa s\u00fcreli zamanlama gerektiren h\u0131zl\u0131 d\u00f6ng\u00fc uygulamalar\u0131 i\u00e7in<\/li>\n<li>1-10s: Standart k\u0131sa d\u00f6ng\u00fcl\u00fc end\u00fcstriyel prosesler i\u00e7in ideal<\/li>\n<li>0.1-1m: Dakika bazl\u0131 s\u00fcre\u00e7 kontrol\u00fc i\u00e7in m\u00fckemmel<\/li>\n<li>1-10m: Daha uzun proses d\u00f6ng\u00fcleri i\u00e7in uygundur<\/li>\n<li>0.1-1 saat: Saatlik d\u00f6ng\u00fc uygulamalar\u0131 i\u00e7in<\/li>\n<li>1-10 saat: Geni\u015fletilmi\u015f saat bazl\u0131 zamanlama kontrol\u00fc<\/li>\n<li>0.1-1 g\u00fcn: Geni\u015fletilmi\u015f s\u00fcre\u00e7ler i\u00e7in g\u00fcnl\u00fck d\u00f6ng\u00fc kontrol\u00fc<\/li>\n<li>1-10 g\u00fcn: Uzun s\u00fcreli s\u00fcre\u00e7ler i\u00e7in \u00e7ok g\u00fcnl\u00fck zamanlama<\/li>\n<li>3-30 g\u00fcn: Ayl\u0131k d\u00f6ng\u00fc uygulamalar\u0131<\/li>\n<li>10-100 g\u00fcn: Mevsimsel uygulamalar i\u00e7in daha uzun s\u00fcreli zamanlama<\/li>\n<\/ul>\n<h3>Hassas Oran Ayarlar\u0131<\/h3>\n<p>5%'lik art\u0131\u015flarla 10%'den 100%'ye kadar oran ayarlar\u0131yla zamanlama gereksinimlerinize ince ayar yap\u0131n:<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-14179\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-B_Bt-Off-Delay-Timer-Relay-with-Retrigger-Control-Signal-ratio-settings.webp\" alt=\"VIOX FCT18-B_Bt Off-Delay Timer Relay with Retrigger Control Signal ratio settings\" width=\"728\" height=\"196\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-B_Bt-Off-Delay-Timer-Relay-with-Retrigger-Control-Signal-ratio-settings.webp 728w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-B_Bt-Off-Delay-Timer-Relay-with-Retrigger-Control-Signal-ratio-settings-300x81.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-B_Bt-Off-Delay-Timer-Relay-with-Retrigger-Control-Signal-ratio-settings-18x5.webp 18w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-B_Bt-Off-Delay-Timer-Relay-with-Retrigger-Control-Signal-ratio-settings-600x162.webp 600w\" sizes=\"(max-width: 728px) 100vw, 728px\" \/><\/p>\n<h3>Teknik \u00d6zellikler<\/h3>\n<table>\n<tbody>\n<tr>\n<th>\u015eartname<\/th>\n<th>FCT18-B1<\/th>\n<th>FCT18-B2<\/th>\n<th>FCT18-Bt<\/th>\n<\/tr>\n<tr>\n<td>Giri\u015f Terminali<\/td>\n<td>A1-A2<\/td>\n<td>A1-A2<\/td>\n<td>A1-A2<\/td>\n<\/tr>\n<tr>\n<td>Gerilim aral\u0131\u011f\u0131<\/td>\n<td>AC 230V \/ DC24V \/ AC\/DC 12-240V<\/td>\n<td>AC 230V \/ DC24V \/ AC\/DC 12-240V<\/td>\n<td>AC 230V \/ DC24V \/ AC\/DC 12-240V<\/td>\n<\/tr>\n<tr>\n<td>G\u00fc\u00e7 t\u00fcketimi<\/td>\n<td>AC 3.5VA\/ DC 2.0W<\/td>\n<td>AC 3.5VA\/ DC 2.0W<\/td>\n<td>AC 3.5VA\/ DC 2.0W<\/td>\n<\/tr>\n<tr>\n<td>Gerilim tolerans\u0131<\/td>\n<td>-15% ~ +10%<\/td>\n<td>-15% ~ +10%<\/td>\n<td>-15% ~ +10%<\/td>\n<\/tr>\n<tr>\n<td>Besleme g\u00f6stergesi<\/td>\n<td>Ye\u015fil LED<\/td>\n<td>Ye\u015fil LED<\/td>\n<td>Ye\u015fil LED<\/td>\n<\/tr>\n<tr>\n<td>R\u00f6le g\u00f6stergesi<\/td>\n<td>K\u0131rm\u0131z\u0131 LED<\/td>\n<td>K\u0131rm\u0131z\u0131 LED<\/td>\n<td>K\u0131rm\u0131z\u0131 LED<\/td>\n<\/tr>\n<tr>\n<td>Zaman aral\u0131klar\u0131<\/td>\n<td>0.1s-100days<\/td>\n<td>0.1s-100days<\/td>\n<td>0.1s-100days<\/td>\n<\/tr>\n<tr>\n<td>Zaman ayar\u0131<\/td>\n<td>d\u00fc\u011fme<\/td>\n<td>d\u00fc\u011fme<\/td>\n<td>d\u00fc\u011fme<\/td>\n<\/tr>\n<tr>\n<td>Zaman sapmas\u0131<\/td>\n<td>0.1%<\/td>\n<td>0.1%<\/td>\n<td>0.1%<\/td>\n<\/tr>\n<tr>\n<td>Tekrarlama do\u011frulu\u011fu<\/td>\n<td>0.5%<\/td>\n<td>0.5%<\/td>\n<td>0.5%<\/td>\n<\/tr>\n<tr>\n<td>S\u0131cakl\u0131k katsay\u0131s\u0131<\/td>\n<td>0,05%\/\u00b0C, at=20\u00b0C (0,05%\/\u00b0F, =68\u00b0F)<\/td>\n<td>0,05%\/\u00b0C, at=20\u00b0C (0,05%\/\u00b0F, =68\u00b0F)<\/td>\n<td>0,05%\/\u00b0C, at=20\u00b0C (0,05%\/\u00b0F, =68\u00b0F)<\/td>\n<\/tr>\n<tr>\n<td>\u00c7\u0131k\u0131\u015f konta\u011f\u0131<\/td>\n<td>1*SPDT<\/td>\n<td>2*SPDT<\/td>\n<td>1*SPDT+1*SPDT<\/td>\n<\/tr>\n<tr>\n<td>Nominal ak\u0131m<\/td>\n<td>1*16A<\/td>\n<td>2*16A<\/td>\n<td>2*16A<\/td>\n<\/tr>\n<tr>\n<td>Mekanik \u00f6m\u00fcr<\/td>\n<td>1*10\u2077<\/td>\n<td>1*10\u2077<\/td>\n<td>1*10\u2077<\/td>\n<\/tr>\n<tr>\n<td>Elektriksel \u00f6m\u00fcr<\/td>\n<td>1*10\u2075<\/td>\n<td>1*10\u2075<\/td>\n<td>1*10\u2075<\/td>\n<\/tr>\n<tr>\n<td>Ortam s\u0131cakl\u0131\u011f\u0131<\/td>\n<td>-20 ... +60\u00b0C \/ -40 ... +85\u00b0C<\/td>\n<td>-20 ... +60\u00b0C \/ -40 ... +85\u00b0C<\/td>\n<td>-20 ... +60\u00b0C \/ -40 ... +85\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Montaj<\/td>\n<td>DIN ray\u0131 EN\/IEC 60715<\/td>\n<td>DIN ray\u0131 EN\/IEC 60715<\/td>\n<td>DIN ray\u0131 EN\/IEC 60715<\/td>\n<\/tr>\n<tr>\n<td>IP Derecesi<\/td>\n<td>IP20<\/td>\n<td>IP20<\/td>\n<td>IP20<\/td>\n<\/tr>\n<tr>\n<td>S\u0131y\u0131rma uzunlu\u011fu<\/td>\n<td>7 mm (0,28 in\u00e7)<\/td>\n<td>7 mm (0,28 in\u00e7)<\/td>\n<td>7 mm (0,28 in\u00e7)<\/td>\n<\/tr>\n<tr>\n<td>Kurulu y\u00fckseklik<\/td>\n<td>\u22642200m<\/td>\n<td>\u22642200m<\/td>\n<td>\u22642200m<\/td>\n<\/tr>\n<tr>\n<td>Kirlilik seviyesi<\/td>\n<td>2<\/td>\n<td>2<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td>Maksimum kablo boyutu<\/td>\n<td>AWG13-20 0,4N-m<\/td>\n<td>AWG13-20 0,4N-m<\/td>\n<td>AWG13-20 0,4N-m<\/td>\n<\/tr>\n<tr>\n<td>Boyut<\/td>\n<td>90mm\u00d718mm\u00d764mm<\/td>\n<td>90mm\u00d718mm\u00d764mm<\/td>\n<td>90mm\u00d718mm\u00d764mm<\/td>\n<\/tr>\n<tr>\n<td>A\u011f\u0131rl\u0131k<\/td>\n<td>yakla\u015f\u0131k 90g<\/td>\n<td>yakla\u015f\u0131k 90g<\/td>\n<td>yakla\u015f\u0131k 90g<\/td>\n<\/tr>\n<tr>\n<td>Standartlar<\/td>\n<td>GB\/T 14048.5, IEC60947-5-1, EN6812-1<\/td>\n<td>GB\/T 14048.5, IEC60947-5-1, EN6812-1<\/td>\n<td>GB\/T 14048.5, IEC60947-5-1, EN6812-1<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>\u00c7\u0131kt\u0131 Se\u00e7enekleri<\/h3>\n<p>FCT18-B\/Bt serisi, kontrol gereksinimlerinizi kar\u015f\u0131lamak i\u00e7in \u00e7oklu \u00e7\u0131k\u0131\u015f konfig\u00fcrasyonlar\u0131 sunar:<\/p>\n<ul>\n<li><strong>FCT18-B1<\/strong>: 1CO konta\u011f\u0131 (1\u00d7SPDT)<\/li>\n<li><strong>FCT18-B2<\/strong>: 2CO kontaklar\u0131 (2\u00d7SPDT)<\/li>\n<li><strong>FCT18-Bt<\/strong>: 1CO kontak + 1 anl\u0131k kontak (1\u00d7SPDT + 1\u00d7SPDT)<\/li>\n<\/ul>\n<h3>Kontrol Sinyali Se\u00e7enekleri<\/h3>\n<ul>\n<li><strong>N<\/strong>: NPN kontrol sinyali<\/li>\n<li><strong>P<\/strong>: PNP kontrol sinyali<\/li>\n<\/ul>\n<h2>Kapal\u0131 Gecikmeli Zamanlay\u0131c\u0131 R\u00f6leleri i\u00e7in Yayg\u0131n End\u00fcstriyel Uygulamalar<\/h2>\n<p>FCT18-B\/Bt gibi zamanlay\u0131c\u0131 r\u00f6leler, \u00e7ok say\u0131da end\u00fcstriyel uygulamada kritik zamanlama i\u015flevleri sa\u011flar:<\/p>\n<h3>Ayd\u0131nlatma Kontrol\u00fc<\/h3>\n<p>Off-delay zamanlay\u0131c\u0131 r\u00f6leleri, \u00fcretim tesislerinde veya seralarda birden fazla lamba s\u0131ras\u0131n\u0131n gecikmeli olarak anahtarlanmas\u0131n\u0131 sa\u011flayarak uygun ayd\u0131nlatma d\u00f6ng\u00fcleri ve enerji verimlili\u011fi sa\u011flar.<\/p>\n<h3>Motor Kontrol\u00fc<\/h3>\n<p>De\u011fi\u015fim gecikmeli y\u0131ld\u0131z-\u00fc\u00e7gen motor ba\u015flatma, ba\u015flatma ak\u0131m\u0131n\u0131 azaltmaya yard\u0131mc\u0131 olur ve fazlar aras\u0131 k\u0131sa devreleri \u00f6nleyerek de\u011ferli ekipman\u0131 korur ve motor \u00f6mr\u00fcn\u00fc uzat\u0131r.<\/p>\n<h3>D\u00f6ng\u00fcsel \u0130\u015flemler<\/h3>\n<p>Makinelerin s\u0131k\u0131\u015fmas\u0131n\u0131 \u00f6nlemek i\u00e7in fanlar\u0131n haftal\u0131k olarak \u00e7al\u0131\u015ft\u0131r\u0131lmas\u0131n\u0131 y\u00f6netin veya temiz kalmalar\u0131n\u0131 sa\u011flamak i\u00e7in borular\u0131n y\u0131kanmas\u0131n\u0131 kontrol edin; bak\u0131m otomasyonu i\u00e7in idealdir.<\/p>\n<h3>Ek Uygulamalar<\/h3>\n<ul>\n<li><strong>Kontrol panelleri<\/strong>: Hassas zamanlama ile s\u0131ral\u0131 i\u015flemler<\/li>\n<li><strong>Pompa kontrolleri<\/strong>: Kuru \u00e7al\u0131\u015fmay\u0131 \u00f6nleyin ve s\u0131v\u0131 seviyelerini y\u00f6netin<\/li>\n<li><strong>Makine aletleri<\/strong>: Operasyonel dizileri kontrol edin<\/li>\n<li><strong>Otomatik kap\u0131lar<\/strong>: A\u00e7\u0131l\u0131\u015f\/kapan\u0131\u015f d\u00f6ng\u00fclerini y\u00f6netin<\/li>\n<li><strong>Otopark bariyerleri<\/strong>: Trafik ak\u0131\u015f\u0131n\u0131 d\u00fczenlemek<\/li>\n<li><strong>Kompres\u00f6r kontrolleri<\/strong>: Bas\u0131n\u00e7 d\u00f6ng\u00fclerini optimize edin<\/li>\n<li><strong>Ula\u015f\u0131m sistemleri<\/strong>: Hareketi senkronize et<\/li>\n<li><strong>End\u00fcstriyel so\u011futma<\/strong>: Buz \u00e7\u00f6zme d\u00f6ng\u00fclerini y\u00f6netme<\/li>\n<li><strong>Paketleme makineleri<\/strong>: \u00dcr\u00fcn kullan\u0131m\u0131n\u0131 kontrol edin<\/li>\n<li><strong>Pi\u015firme f\u0131r\u0131nlar\u0131<\/strong>: S\u0131cakl\u0131k d\u00f6ng\u00fclerini y\u00f6netin<\/li>\n<li><strong>Su ve at\u0131k su<\/strong>: Kontrol ar\u0131tma s\u00fcre\u00e7leri<\/li>\n<li><strong>R\u00fczgar enerjisi<\/strong>: T\u00fcrbin operasyonlar\u0131n\u0131 senkronize edin<\/li>\n<li><strong>End\u00fcstriyel temizlik<\/strong>: Temizlik dizilerini otomatikle\u015ftirin<\/li>\n<\/ul>\n<h2>VIOX FCT18-B\/Bt Kapal\u0131 Gecikmeli Zamanlay\u0131c\u0131 R\u00f6lesinin Avantajlar\u0131<\/h2>\n<h3>\u00c7ok Y\u00f6nl\u00fc G\u00fc\u00e7 Kayna\u011f\u0131<\/h3>\n<p>FCT18-B\/Bt, 12 ila 240 VAC\/DC aras\u0131nda geni\u015f bir g\u00fc\u00e7 kayna\u011f\u0131 aral\u0131\u011f\u0131yla, ek g\u00fc\u00e7 d\u00f6n\u00fc\u015ft\u00fcr\u00fcc\u00fcleri gerektirmeden neredeyse t\u00fcm elektrik sistemlerine entegre edilebilir.<\/p>\n<h3>Kullan\u0131c\u0131 Dostu Kurulum<\/h3>\n<p>Kurulum, \u00fcr\u00fcn\u00fcn yan taraf\u0131ndaki a\u00e7\u0131k kablo ba\u011flant\u0131 \u015femalar\u0131 ile basitle\u015ftirilerek kurulum s\u00fcresi k\u0131salt\u0131l\u0131r ve ba\u011flant\u0131 hatas\u0131 riski en aza indirilir.<\/p>\n<h3>Ola\u011fan\u00fcst\u00fc Do\u011fruluk<\/h3>\n<p>FCT18-B\/Bt, 0,5%'den daha az zaman hatas\u0131, 0,1% zaman sapmas\u0131 ve 0,5% tekrarlama do\u011frulu\u011fu ile kritik end\u00fcstriyel s\u00fcre\u00e7ler i\u00e7in gereken hassas zamanlamay\u0131 sa\u011flar.<\/p>\n<h3>End\u00fcstriyel S\u0131n\u0131f G\u00fcvenilirlik<\/h3>\n<p>G\u00fc\u00e7l\u00fc parazit \u00f6nleme \u00f6zelli\u011fi, elektriksel ani y\u00fckselmelerin ve dalgalanmalar\u0131n yayg\u0131n oldu\u011fu elektriksel olarak g\u00fcr\u00fclt\u00fcl\u00fc end\u00fcstriyel ortamlarda bile tutarl\u0131 \u00e7al\u0131\u015fma sa\u011flar.<\/p>\n<h3>Kompakt Tasar\u0131m<\/h3>\n<p>90mm\u00d718mm\u00d764mm boyutlar\u0131yla FCT18-B\/Bt, kompakt bir pakette \u00f6nemli i\u015flevsellik sunarak kontrol panellerinde ve elektrik muhafazalar\u0131nda de\u011ferli alan tasarrufu sa\u011flar.<\/p>\n<h3>G\u00f6rsel Durum G\u00f6stergesi<\/h3>\n<ul>\n<li><strong>Ye\u015fil LED<\/strong>: Besleme g\u00f6stergesi<\/li>\n<li><strong>K\u0131rm\u0131z\u0131 LED<\/strong>: R\u00f6le aktivasyon g\u00f6stergesi<\/li>\n<\/ul>\n<h2>\u0130zleme ve Koruma \u00d6zellikleri<\/h2>\n<p>FCT18-B\/Bt zaman r\u00f6lesi, kapsaml\u0131 bir kontrol ve izleme sisteminin par\u00e7as\u0131 olarak i\u015flev g\u00f6r\u00fcr:<\/p>\n<h3>\u00dc\u00e7 Fazl\u0131 Gerilim \u0130zleme<\/h3>\n<ul>\n<li>Mobil \u00fc\u00e7 fazl\u0131 ekipman\u0131n gerilim izlemesi<\/li>\n<li>Personelin ve tesislerin faz de\u011fi\u015fimine kar\u015f\u0131 korunmas\u0131<\/li>\n<li>Makine ve tesislerin besleme geriliminin izlenmesi<\/li>\n<li>Dengesiz besleme geriliminden kaynaklanan hasarlara kar\u015f\u0131 koruma<\/li>\n<li>Gerekti\u011finde acil durum veya yard\u0131mc\u0131 beslemeye ge\u00e7me<\/li>\n<\/ul>\n<h3>Tek fazl\u0131 Ak\u0131m \u0130zleme<\/h3>\n<ul>\n<li>Motor ak\u0131m t\u00fcketiminin izlenmesi<\/li>\n<li>Ayd\u0131nlatma tesisatlar\u0131n\u0131n ve \u0131s\u0131tma devrelerinin izlenmesi<\/li>\n<li>Ta\u015f\u0131ma ekipmanlar\u0131n\u0131n a\u015f\u0131r\u0131 y\u00fcklenmesinin izlenmesi<\/li>\n<li>Kilitleme cihazlar\u0131n\u0131n, elektromekanik fren di\u015flilerinin ve kilitli rotorlar\u0131n izlenmesi<\/li>\n<\/ul>\n<h3>Tek Fazl\u0131 Gerilim \u0130zleme<\/h3>\n<ul>\n<li>DC motorlar\u0131n h\u0131z takibi<\/li>\n<li>Ak\u00fc voltajlar\u0131n\u0131n ve di\u011fer besleme a\u011flar\u0131n\u0131n izlenmesi<\/li>\n<\/ul>\n<h3>S\u0131v\u0131 Seviyesi \u0130zleme<\/h3>\n<ul>\n<li>Pompalar\u0131n kuru \u00e7al\u0131\u015fmaya kar\u015f\u0131 korunmas\u0131<\/li>\n<li>Konteyner ta\u015fmas\u0131na kar\u015f\u0131 koruma<\/li>\n<li>S\u0131v\u0131 seviyelerinin kontrol\u00fc<\/li>\n<li>S\u0131z\u0131nt\u0131lar\u0131n tespiti<\/li>\n<li>Kar\u0131\u015f\u0131m oranlar\u0131n\u0131n kontrol\u00fc<\/li>\n<\/ul>\n<h2>Kurulum ve Ayarlama<\/h2>\n<h3>Kablolama Se\u00e7enekleri<\/h3>\n<p>FCT18-B\/Bt hem NPN hem de PNP kontrol sinyali konfig\u00fcrasyonlar\u0131n\u0131 destekler:<\/p>\n<h4>NPN Konfig\u00fcrasyonu<\/h4>\n<ul>\n<li>Un'u g\u00fc\u00e7 kayna\u011f\u0131na ba\u011flay\u0131n<\/li>\n<li>S'yi kontrol sinyaline ba\u011flay\u0131n<\/li>\n<li>\u00c7\u0131k\u0131\u015f terminalleri: 11-14 (R1) ve 21-24 (R2)<\/li>\n<\/ul>\n<h4>PNP Konfig\u00fcrasyonu<\/h4>\n<ul>\n<li>Un'u g\u00fc\u00e7 kayna\u011f\u0131na ba\u011flay\u0131n<\/li>\n<li>S'yi kontrol sinyaline ba\u011flay\u0131n<\/li>\n<li>\u00c7\u0131k\u0131\u015f terminalleri: 11-14 (R1) ve 21-24 (R2)<\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-14180\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-B_Bt-Off-Delay-Timer-Relay-with-Retrigger-Control-Signal-wiring.webp\" alt=\"VIOX FCT18-B_Bt Off-Delay Timer Relay with Retrigger Control Signal wiring\" width=\"324\" height=\"284\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-B_Bt-Off-Delay-Timer-Relay-with-Retrigger-Control-Signal-wiring.webp 324w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-B_Bt-Off-Delay-Timer-Relay-with-Retrigger-Control-Signal-wiring-300x263.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-B_Bt-Off-Delay-Timer-Relay-with-Retrigger-Control-Signal-wiring-14x12.webp 14w\" sizes=\"(max-width: 324px) 100vw, 324px\" \/><\/p>\n<h3>Boyut \u00d6zellikleri<\/h3>\n<p>Kompakt tasar\u0131m, standart kontrol panellerine kolay kurulum sa\u011flar:<\/p>\n<ul>\n<li>Y\u00fckseklik: 90mm<\/li>\n<li>Geni\u015flik: 18mm<\/li>\n<li>Derinlik: 64mm<\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-14181\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-B_Bt-Off-Delay-Timer-Relay-with-Retrigger-Control-Signal-dimension.webp\" alt=\"VIOX FCT18-B_Bt Off-Delay Timer Relay with Retrigger Control Signal dimension\" width=\"324\" height=\"290\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-B_Bt-Off-Delay-Timer-Relay-with-Retrigger-Control-Signal-dimension.webp 324w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-B_Bt-Off-Delay-Timer-Relay-with-Retrigger-Control-Signal-dimension-300x269.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-B_Bt-Off-Delay-Timer-Relay-with-Retrigger-Control-Signal-dimension-13x12.webp 13w\" sizes=\"(max-width: 324px) 100vw, 324px\" \/><\/p>\n<h2>Model Se\u00e7im K\u0131lavuzu<\/h2>\n<p>FCT18 model tan\u0131mlama sistemi, uygulaman\u0131z i\u00e7in tam olarak do\u011fru zaman r\u00f6lesini belirlemenizi sa\u011flar:<\/p>\n<p><strong>FCT18- B 1 W N<\/strong><\/p>\n<ol>\n<li><strong>Fonksiyon<\/strong>: B (Kapal\u0131 gecikme) veya Bt (Kapal\u0131 gecikme + anl\u0131k)<\/li>\n<li><strong>\u00c7\u0131kt\u0131 t\u00fcr\u00fc<\/strong>: 1 (1CO konta\u011f\u0131) veya 2 (2CO konta\u011f\u0131)<\/li>\n<li><strong>Besleme gerilimi<\/strong>: A (AC230V), D (DC24V) veya W (AC\/DC12-240V)<\/li>\n<li><strong>Kontrol sinyali<\/strong>: N (NPN) veya P (PNP)<\/li>\n<\/ol>\n<h2>Kalite Standartlar\u0131<\/h2>\n<p>VIOX FCT18-B\/Bt uluslararas\u0131 standartlara uygun olarak \u00fcretilmi\u015ftir:<\/p>\n<ul>\n<li>GB\/T 14048.5<\/li>\n<li>IEC60947-5-1<\/li>\n<li>EN6812-1<\/li>\n<\/ul>\n<h2>Sonu\u00e7<\/h2>\n<p>VIOX FCT18-B\/Bt off-delay zamanlay\u0131c\u0131 r\u00f6lesi, hassasiyet, g\u00fcvenilirlik ve \u00e7ok y\u00f6nl\u00fcl\u00fck gerektiren end\u00fcstriyel zamanlama uygulamalar\u0131 i\u00e7in ideal bir \u00e7\u00f6z\u00fcm\u00fc temsil eder. Geni\u015f zamanlama fonksiyonlar\u0131 yelpazesi, ola\u011fan\u00fcst\u00fc do\u011frulu\u011fu ve sa\u011flam tasar\u0131m\u0131 ile zorlu end\u00fcstriyel ortamlarda tutarl\u0131 performans sunar.<\/p>\n<p>\u0130ster ayd\u0131nlatma sistemlerinin, ister motor \u00e7al\u0131\u015ft\u0131rma s\u0131ralar\u0131n\u0131n veya d\u00f6ng\u00fcsel i\u015flemlerin hassas kontrol\u00fcne ihtiyac\u0131n\u0131z olsun, FCT18-B\/Bt verimli otomasyon i\u00e7in gereken zamanlama i\u015flevselli\u011fini sa\u011flar. Kullan\u0131c\u0131 dostu kurulumu, kompakt tasar\u0131m\u0131 ve kapsaml\u0131 izleme \u00f6zellikleri, onu modern end\u00fcstriyel kontrol sistemlerinde \u00f6nemli bir bile\u015fen haline getirir.<\/p>\n<p>Motorlar\u0131 \u00e7al\u0131\u015ft\u0131rmak, y\u00fckleri kontrol etmek veya s\u00fcre\u00e7leri y\u00f6netmek i\u00e7in g\u00fcvenilir zaman gecikmeli anahtarlama gerektiren uygulamalar i\u00e7in VIOX FCT18-B\/Bt kapal\u0131 gecikmeli zamanlay\u0131c\u0131 r\u00f6lesi, performans, dayan\u0131kl\u0131l\u0131k ve de\u011feri bir araya getiren profesyonel d\u00fczeyde bir \u00e7\u00f6z\u00fcm sunar.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<div class=\"markdown\">\n<p>VIOX FCT18-B\/Bt Off-Delay Timer Relay, end\u00fcstriyel kontrol sistemleri i\u00e7in hassas aral\u0131kl\u0131 zamanlama sa\u011flar. &lt;0,5% hata ile geni\u015f bir zaman aral\u0131\u011f\u0131 (0,1s - 100 g\u00fcn), yeniden tetikleme kontrol sinyali giri\u015fi (NPN\/PNP) ve DIN ray montaj\u0131na sahiptir. Kontroll\u00fc kapatmalar ve proses zamanlamas\u0131 i\u00e7in idealdir.<\/p>\n<\/div>","protected":false},"featured_media":14182,"comment_status":"closed","ping_status":"closed","template":"","meta":{"inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[],"product_cat":[196,123],"product_tag":[],"class_list":{"0":"post-14176","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-time-relay","7":"product_cat-relay","8":"desktop-align-left","9":"tablet-align-left","10":"mobile-align-left","12":"first","13":"instock","14":"shipping-taxable","15":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product\/14176","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/comments?post=14176"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/media\/14182"}],"wp:attachment":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/media?parent=14176"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product_brand?post=14176"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product_cat?post=14176"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product_tag?post=14176"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}