{"id":14169,"date":"2025-03-19T17:08:21","date_gmt":"2025-03-19T09:08:21","guid":{"rendered":"https:\/\/viox.com\/?post_type=product&#038;p=14169"},"modified":"2025-03-19T20:07:48","modified_gmt":"2025-03-19T12:07:48","slug":"viox-fct18-a-at-power-on-delay-timer-relay","status":"publish","type":"product","link":"https:\/\/test.viox.com\/tr\/urun\/viox-fct18-a-at-power-on-delay-timer-relay\/","title":{"rendered":"VIOX FCT18-A\/At G\u00fc\u00e7 A\u00e7\u0131k-Gecikmeli zamanlay\u0131c\u0131 R\u00f6lesi, Yeniden Tetikleme Kontrol Sinyali ile"},"content":{"rendered":"<div class=\"product-intro\">\n<h2>End\u00fcstriyel Uygulamalar i\u00e7in Hassas Zamanlama Kontrol\u00fc<\/h2>\n<p>VIOX FCT18-A\/At, \u00e7ok \u00e7e\u015fitli end\u00fcstriyel uygulamalar i\u00e7in g\u00fcvenilir, hassas zamanlama kontrol\u00fc sa\u011flamak \u00fczere tasarlanm\u0131\u015f geli\u015fmi\u015f bir g\u00fc\u00e7 a\u00e7ma gecikmeli zamanlay\u0131c\u0131 r\u00f6lesidir. Ola\u011fan\u00fcst\u00fc do\u011fruluk, \u00e7ok y\u00f6nl\u00fc yap\u0131land\u0131rma se\u00e7enekleri ve sa\u011flam yap\u0131ya sahip olan bu zamanlay\u0131c\u0131 r\u00f6lesi, g\u00fcvenilir zaman gecikmeli anahtarlama i\u015flemleri gerektiren otomatik sistemler i\u00e7in ideal \u00e7\u00f6z\u00fcmd\u00fcr.<\/p>\n<h2>\u00dcr\u00fcne Genel Bak\u0131\u015f<\/h2>\n<p>FCT18-A\/At g\u00fc\u00e7 a\u00e7ma-geciktirme zamanlay\u0131c\u0131 r\u00f6lesi, zorlu end\u00fcstriyel ortamlarda tutarl\u0131 performans sunmak \u00fczere tasarlanm\u0131\u015ft\u0131r. Bu r\u00f6le, 0,1 saniye ile 100 g\u00fcn aras\u0131nda de\u011fi\u015fen zaman aral\u0131klar\u0131 ve 0,5%'den daha az zaman hatas\u0131 ile kritik end\u00fcstriyel prosesler i\u00e7in gereken hassas zamanlama kontrol\u00fcn\u00fc sa\u011flar. R\u00f6lenin yeniden tetikleme kontrol sinyali i\u015flevi, karma\u015f\u0131k zamanlama dizileri i\u00e7in geli\u015fmi\u015f esneklik sunarak onu \u00e7ok \u00e7e\u015fitli uygulamalar i\u00e7in uygun hale getirir.<\/p>\n<h3>Temel \u00d6zellikler ve Avantajlar<\/h3>\n<ul>\n<li><strong>Geni\u015f Zaman Aral\u0131\u011f\u0131:<\/strong> \u00c7e\u015fitli uygulama gereksinimleri i\u00e7in esneklik sa\u011flayarak 0,1 saniyeden 100 g\u00fcne kadar zamanlama kontrol\u00fc sunar<\/li>\n<li><strong>Y\u00fcksek Do\u011fruluk:<\/strong> 0,5%'den daha az zaman hatas\u0131, kritik zamanlama uygulamalar\u0131 i\u00e7in hassas \u00e7al\u0131\u015fma sa\u011flar<\/li>\n<li><strong>\u00c7ok Y\u00f6nl\u00fc G\u00fc\u00e7 Kayna\u011f\u0131:<\/strong> \u00c7o\u011fu end\u00fcstriyel g\u00fc\u00e7 sistemiyle uyumlu, 12 ila 240 VAC\/DC aras\u0131nda geni\u015f g\u00fc\u00e7 kayna\u011f\u0131 aral\u0131\u011f\u0131<\/li>\n<li><strong>Kullan\u0131c\u0131 Dostu Kurulum:<\/strong> \u00dcr\u00fcn\u00fcn yan taraf\u0131nda bas\u0131l\u0131 kablo ba\u011flant\u0131 \u015femalar\u0131 ile kolay yap\u0131land\u0131rma<\/li>\n<li><strong>G\u00fc\u00e7l\u00fc Parazit \u00d6nleme \u00d6zelli\u011fi:<\/strong> Elektriksel g\u00fcr\u00fclt\u00fc ve parazit bulunan ortamlarda bile g\u00fcvenilir \u00e7al\u0131\u015fma<\/li>\n<li><strong>G\u00f6rsel Durum G\u00f6stergesi:<\/strong> Besleme g\u00f6stergesi i\u00e7in ye\u015fil LED ve r\u00f6le durumu i\u00e7in k\u0131rm\u0131z\u0131 LED, h\u0131zl\u0131 g\u00f6rsel do\u011frulama sa\u011flar<\/li>\n<li><strong>DIN Ray Montaj\u0131:<\/strong> Kontrol panellerine kolay kurulum i\u00e7in standart DIN ray montaj\u0131 (EN\/IEC 60715)<\/li>\n<li><strong>Kompakt Tasar\u0131m:<\/strong> Yer tasarrufu sa\u011flayan 90mm*18mm*64mm boyutlar\u0131, y\u00fcksek yo\u011funluklu kontrol panelleri i\u00e7in idealdir<\/li>\n<\/ul>\n<h2>Teknik \u00d6zellikler<\/h2>\n<table border=\"1\" cellspacing=\"0\" cellpadding=\"5\">\n<tbody>\n<tr>\n<th colspan=\"4\">FCT18-A\/At Zamanlay\u0131c\u0131 R\u00f6lesi \u00d6zellikleri<\/th>\n<\/tr>\n<tr>\n<td><strong>Parametre<\/strong><\/td>\n<td><strong>FCT18-A1<\/strong><\/td>\n<td><strong>FCT18-A2<\/strong><\/td>\n<td><strong>FCT18-At<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Giri\u015f Terminali<\/td>\n<td colspan=\"3\">A1-A2<\/td>\n<\/tr>\n<tr>\n<td>Gerilim aral\u0131\u011f\u0131<\/td>\n<td colspan=\"3\">AC 230V \/ DC24V \/ AC\/DC 12-240V<\/td>\n<\/tr>\n<tr>\n<td>G\u00fc\u00e7 t\u00fcketimi<\/td>\n<td colspan=\"3\">AC 3.5VA\/ DC 2.0W<\/td>\n<\/tr>\n<tr>\n<td>Gerilim tolerans\u0131<\/td>\n<td colspan=\"3\">-15% ~ +10%<\/td>\n<\/tr>\n<tr>\n<td>Besleme g\u00f6stergesi<\/td>\n<td colspan=\"3\">Ye\u015fil LED<\/td>\n<\/tr>\n<tr>\n<td>R\u00f6le g\u00f6stergesi<\/td>\n<td colspan=\"3\">K\u0131rm\u0131z\u0131 LED<\/td>\n<\/tr>\n<tr>\n<td>Zaman aral\u0131klar\u0131<\/td>\n<td colspan=\"3\">0.1s-100days<\/td>\n<\/tr>\n<tr>\n<td>Zaman ayar\u0131<\/td>\n<td colspan=\"3\">d\u00fc\u011fme<\/td>\n<\/tr>\n<tr>\n<td>Zaman sapmas\u0131<\/td>\n<td colspan=\"3\">0.1%<\/td>\n<\/tr>\n<tr>\n<td>Tekrarlama do\u011frulu\u011fu<\/td>\n<td colspan=\"3\">0.5%<\/td>\n<\/tr>\n<tr>\n<td>S\u0131cakl\u0131k katsay\u0131s\u0131<\/td>\n<td colspan=\"3\">0,05%\/\u00b0C, \u224820\u00b0C'de (0,05%\/\u00b0F, \u224868\u00b0F)<\/td>\n<\/tr>\n<tr>\n<td>\u00c7\u0131k\u0131\u015f konta\u011f\u0131<\/td>\n<td>1*SPDT<\/td>\n<td>2*SPDT<\/td>\n<td>1*SPDT+1*SPDT<\/td>\n<\/tr>\n<tr>\n<td>Nominal ak\u0131m<\/td>\n<td>1*16A<\/td>\n<td>2*16A<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Mekanik \u00f6m\u00fcr<\/td>\n<td colspan=\"3\">1*10\u2077<\/td>\n<\/tr>\n<tr>\n<td>Elektriksel \u00f6m\u00fcr<\/td>\n<td colspan=\"3\">1*10\u2075<\/td>\n<\/tr>\n<tr>\n<td>Ortam S\u0131cakl\u0131\u011f\u0131<\/td>\n<td colspan=\"3\">-20...+60\u00b0C\/-40...+85\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Montaj<\/td>\n<td colspan=\"3\">DIN ray\u0131 EN\/IEC 60715<\/td>\n<\/tr>\n<tr>\n<td>IP Derecesi<\/td>\n<td colspan=\"3\">IP20<\/td>\n<\/tr>\n<tr>\n<td>S\u0131y\u0131rma uzunlu\u011fu<\/td>\n<td colspan=\"3\">7 mm (0,28 in\u00e7)<\/td>\n<\/tr>\n<tr>\n<td>Kurulu y\u00fckseklik<\/td>\n<td colspan=\"3\">\u22642200m<\/td>\n<\/tr>\n<tr>\n<td>Kirlilik seviyesi<\/td>\n<td colspan=\"3\">2<\/td>\n<\/tr>\n<tr>\n<td>Maksimum kablo boyutu<\/td>\n<td colspan=\"3\">AWG13-20 0.4Nm<\/td>\n<\/tr>\n<tr>\n<td>Boyut<\/td>\n<td colspan=\"3\">90mm*18mm*64mm<\/td>\n<\/tr>\n<tr>\n<td>A\u011f\u0131rl\u0131k<\/td>\n<td colspan=\"3\">yakla\u015f\u0131k 90g<\/td>\n<\/tr>\n<tr>\n<td>Standartlar<\/td>\n<td colspan=\"3\">GB\/T 14048.5, IEC60947-5-1, EN61812-1<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Zamanlama Fonksiyonlar\u0131<\/h2>\n<p>FCT18-A\/At zamanlay\u0131c\u0131 r\u00f6lesi, \u00e7e\u015fitli uygulama gereksinimlerini kar\u015f\u0131lamak i\u00e7in tasarlanm\u0131\u015f iki temel zamanlama i\u015flevi sunar:<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-14171\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-A_At-Power-On-Delay-Relay-with-Retrigger-Control-Signal-timing-functions.webp\" alt=\"VIOX FCT18-A_At Power On-Delay Relay with Retrigger Control Signal timing functions\" width=\"778\" height=\"468\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-A_At-Power-On-Delay-Relay-with-Retrigger-Control-Signal-timing-functions.webp 778w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-A_At-Power-On-Delay-Relay-with-Retrigger-Control-Signal-timing-functions-300x180.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-A_At-Power-On-Delay-Relay-with-Retrigger-Control-Signal-timing-functions-768x462.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-A_At-Power-On-Delay-Relay-with-Retrigger-Control-Signal-timing-functions-18x12.webp 18w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-A_At-Power-On-Delay-Relay-with-Retrigger-Control-Signal-timing-functions-600x361.webp 600w\" sizes=\"(max-width: 778px) 100vw, 778px\" \/><\/p>\n<h3>A\u00c7IK-Gecikme (A Fonksiyonu)<\/h3>\n<p>G\u00fc\u00e7 (Un) uyguland\u0131\u011f\u0131nda, zamanlama d\u00f6ng\u00fcs\u00fc (T) ba\u015flar. \u00d6nceden ayarlanan s\u00fcre ge\u00e7tikten sonra \u00e7\u0131k\u0131\u015f r\u00f6lesi (R) durum de\u011fi\u015ftirir. Bu fonksiyon, ekipman aktivasyonundan \u00f6nce bir gecikme gerektiren uygulamalar i\u00e7in idealdir.<\/p>\n<h3>A\u00c7IK-Gecikme + Anl\u0131k (Fonksiyonda)<\/h3>\n<p>Bu geli\u015fmi\u015f fonksiyon, standart A\u00c7IK-gecikmeli \u00e7al\u0131\u015fmay\u0131 anl\u0131k \u00e7\u0131k\u0131\u015fla birle\u015ftirir. G\u00fc\u00e7 (Un) uyguland\u0131\u011f\u0131nda, bir \u00e7\u0131k\u0131\u015f konta\u011f\u0131 (11-14\/R1) hemen durum de\u011fi\u015ftirirken, di\u011fer \u00e7\u0131k\u0131\u015f konta\u011f\u0131 (21-24\/R2) \u00f6nceden ayarlanan s\u00fcre (T) ge\u00e7tikten sonra durum de\u011fi\u015ftirir. Bu \u00e7ift \u00e7\u0131k\u0131\u015f i\u015flevi, hem an\u0131nda hem de gecikmeli yan\u0131t gerektiren uygulamalar i\u00e7in m\u00fckemmeldir.<\/p>\n<h2>Zaman ve Oran Ayar Se\u00e7enekleri<\/h2>\n<p>FCT18-A\/At zamanlay\u0131c\u0131 r\u00f6lesi, \u00e7ok \u00e7e\u015fitli zamanlama gereksinimlerini kar\u015f\u0131lamak i\u00e7in kapsaml\u0131 yap\u0131land\u0131rma se\u00e7enekleri sunar:<\/p>\n<h3>Zaman Aral\u0131\u011f\u0131 Ayarlar\u0131<\/h3>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-14172\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-A_At-Power-On-Delay-Relay-with-Retrigger-Control-Signal-timing-functions-time-rang-settings.webp\" alt=\"VIOX FCT18-A_At Power On-Delay Relay with Retrigger Control Signal timing functions time rang settings\" width=\"858\" height=\"292\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-A_At-Power-On-Delay-Relay-with-Retrigger-Control-Signal-timing-functions-time-rang-settings.webp 858w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-A_At-Power-On-Delay-Relay-with-Retrigger-Control-Signal-timing-functions-time-rang-settings-300x102.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-A_At-Power-On-Delay-Relay-with-Retrigger-Control-Signal-timing-functions-time-rang-settings-768x261.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-A_At-Power-On-Delay-Relay-with-Retrigger-Control-Signal-timing-functions-time-rang-settings-18x6.webp 18w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-A_At-Power-On-Delay-Relay-with-Retrigger-Control-Signal-timing-functions-time-rang-settings-600x204.webp 600w\" sizes=\"(max-width: 858px) 100vw, 858px\" \/><\/p>\n<ul>\n<li>0.1-1s: Hassas k\u0131sa s\u00fcreli zamanlama gerektiren h\u0131zl\u0131 d\u00f6ng\u00fc uygulamalar\u0131 i\u00e7in<\/li>\n<li>1-10s: Standart k\u0131sa d\u00f6ng\u00fcl\u00fc end\u00fcstriyel prosesler i\u00e7in ideal<\/li>\n<li>0.1-1m: Dakika bazl\u0131 s\u00fcre\u00e7 kontrol\u00fc i\u00e7in m\u00fckemmel<\/li>\n<li>1-10m: Daha uzun proses d\u00f6ng\u00fcleri i\u00e7in uygundur<\/li>\n<li>0.1-1 saat: Saatlik d\u00f6ng\u00fc uygulamalar\u0131 i\u00e7in<\/li>\n<li>1-10 saat: Geni\u015fletilmi\u015f saat bazl\u0131 zamanlama kontrol\u00fc<\/li>\n<li>0.1-1 g\u00fcn: Geni\u015fletilmi\u015f s\u00fcre\u00e7ler i\u00e7in g\u00fcnl\u00fck d\u00f6ng\u00fc kontrol\u00fc<\/li>\n<li>1-10 g\u00fcn: Uzun s\u00fcreli s\u00fcre\u00e7ler i\u00e7in \u00e7ok g\u00fcnl\u00fck zamanlama<\/li>\n<li>3-30 g\u00fcn: Ayl\u0131k d\u00f6ng\u00fc uygulamalar\u0131<\/li>\n<li>10-100 g\u00fcn: Mevsimsel uygulamalar i\u00e7in daha uzun s\u00fcreli zamanlama<\/li>\n<\/ul>\n<h3>Oran Ayarlar\u0131<\/h3>\n<p>5%'lik art\u0131\u015flarla 10% ile 100% aras\u0131nda de\u011fi\u015fen 20 oran ayar\u0131 ile zamanlama i\u015flemlerinizde ince ayar yap\u0131n ve her zaman aral\u0131\u011f\u0131nda hassas ayar yap\u0131n.<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-14173\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-A_At-Power-On-Delay-Relay-with-Retrigger-Control-Signal-timing-functions-ratio-settings.webp\" alt=\"VIOX FCT18-A_At Power On-Delay Relay with Retrigger Control Signal timing functions time rang settings\" width=\"800\" height=\"209\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-A_At-Power-On-Delay-Relay-with-Retrigger-Control-Signal-timing-functions-ratio-settings.webp 800w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-A_At-Power-On-Delay-Relay-with-Retrigger-Control-Signal-timing-functions-ratio-settings-300x78.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-A_At-Power-On-Delay-Relay-with-Retrigger-Control-Signal-timing-functions-ratio-settings-768x201.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-A_At-Power-On-Delay-Relay-with-Retrigger-Control-Signal-timing-functions-ratio-settings-18x5.webp 18w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-A_At-Power-On-Delay-Relay-with-Retrigger-Control-Signal-timing-functions-ratio-settings-600x157.webp 600w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<h2>Kablolama Se\u00e7enekleri<\/h2>\n<p>FCT18-A\/At hem NPN hem de PNP kontrol sinyali konfig\u00fcrasyonlar\u0131n\u0131 destekler:<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-14174\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-A_At-Power-On-Delay-Relay-with-Retrigger-Control-Signal-timing-functions-wiring-options.webp\" alt=\"VIOX FCT18-A_At Power On-Delay Relay with Retrigger Control Signal timing functions wiring options\" width=\"438\" height=\"380\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-A_At-Power-On-Delay-Relay-with-Retrigger-Control-Signal-timing-functions-wiring-options.webp 438w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-A_At-Power-On-Delay-Relay-with-Retrigger-Control-Signal-timing-functions-wiring-options-300x260.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-A_At-Power-On-Delay-Relay-with-Retrigger-Control-Signal-timing-functions-wiring-options-14x12.webp 14w\" sizes=\"(max-width: 438px) 100vw, 438px\" \/><\/p>\n<h3>NPN Konfig\u00fcrasyonu<\/h3>\n<p>Kontrol sinyalinin topra\u011fa \u00e7ekti\u011fi negatif mant\u0131k kontrol sinyalleri ile ba\u011flan\u0131r. NPN transist\u00f6r \u00e7\u0131k\u0131\u015flar\u0131 veya batan PLC \u00e7\u0131k\u0131\u015flar\u0131 ile entegrasyon i\u00e7in uygundur.<\/p>\n<h3>PNP Konfig\u00fcrasyonu<\/h3>\n<p>Kontrol sinyalinin pozitif bir voltaj sa\u011flad\u0131\u011f\u0131 pozitif mant\u0131k kontrol sinyalleriyle \u00e7al\u0131\u015f\u0131r. PNP transist\u00f6r \u00e7\u0131k\u0131\u015flar\u0131 veya kaynak PLC \u00e7\u0131k\u0131\u015flar\u0131 ile uyumludur.<\/p>\n<h2>Boyut<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-14175\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-A_At-Power-On-Delay-Relay-with-Retrigger-Control-Signal-dimension.webp\" alt=\"VIOX FCT18-A_At Power On-Delay Relay with Retrigger Control Signal dimension\" width=\"430\" height=\"396\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-A_At-Power-On-Delay-Relay-with-Retrigger-Control-Signal-dimension.webp 430w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-A_At-Power-On-Delay-Relay-with-Retrigger-Control-Signal-dimension-300x276.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-A_At-Power-On-Delay-Relay-with-Retrigger-Control-Signal-dimension-13x12.webp 13w\" sizes=\"(max-width: 430px) 100vw, 430px\" \/><\/p>\n<h2>Uygulamalar<\/h2>\n<p>FCT18-A\/At gibi zaman r\u00f6leleri, \u00e7e\u015fitli end\u00fcstriyel uygulamalar i\u00e7in basit, g\u00fcvenilir ve ekonomik kontrol \u00e7\u00f6z\u00fcmleri sa\u011flar. Motorlar\u0131 \u00e7al\u0131\u015ft\u0131rmak, y\u00fckleri kontrol etmek veya s\u00fcre\u00e7leri y\u00f6netmek i\u00e7in gerekli olan zaman gecikmeli anahtarlama \u00f6zellikleri sunarlar.<\/p>\n<h3>End\u00fcstriyel Kullan\u0131mlar<\/h3>\n<h4>Ayd\u0131nlatma Kontrol\u00fc<\/h4>\n<p>\u00dcretim tesislerinde veya seralarda birden fazla lamba s\u0131ras\u0131n\u0131n gecikmeli olarak anahtarlanmas\u0131n\u0131 sa\u011flar. Hassas zamanlama kontrol\u00fc, enerji tasarruflu ayd\u0131nlatma planlamas\u0131na olanak tan\u0131r ve kontroll\u00fc anahtarlama yoluyla lamba \u00f6mr\u00fcn\u00fc uzat\u0131r.<\/p>\n<h4>Star-Delta Motor \u00c7al\u0131\u015ft\u0131rma<\/h4>\n<p>Fazlar aras\u0131 k\u0131sa devreleri \u00f6nlemek i\u00e7in ge\u00e7i\u015f gecikmesi ile ba\u015flatma ak\u0131m\u0131n\u0131 azalt\u0131n. G\u00fcvenilir zamanlama, uygun motor ba\u015flatma s\u0131ras\u0131n\u0131 sa\u011flayarak pahal\u0131 ekipmanlar\u0131 ak\u0131m dalgalanmalar\u0131ndan korur.<\/p>\n<h4>Makinelerin D\u00f6ng\u00fcsel Anahtarlanmas\u0131<\/h4>\n<p>Yap\u0131\u015fmay\u0131 \u00f6nlemek i\u00e7in fanlar\u0131n haftal\u0131k olarak \u00e7al\u0131\u015ft\u0131r\u0131lmas\u0131n\u0131 sa\u011flay\u0131n veya borular\u0131 temiz tutmak i\u00e7in y\u0131kay\u0131n. Programlanabilir zamanlama d\u00f6ng\u00fcleri, d\u00fczenli otomatik hareket yoluyla ekipman\u0131 optimum \u00e7al\u0131\u015fma ko\u015fullar\u0131nda tutar.<\/p>\n<h3>Ek Uygulamalar<\/h3>\n<ul>\n<li><strong>Kontrol Panelleri:<\/strong> Zamanlama fonksiyonlar\u0131n\u0131n merkezi kontrol sistemlerine entegre edilmesi<\/li>\n<li><strong>Pompa Kontrolleri:<\/strong> Su y\u00f6netimi ve proses uygulamalar\u0131 i\u00e7in pompa \u00e7evrimini y\u00f6netin<\/li>\n<li><strong>Makine Aletleri:<\/strong> \u00dcretim ekipman\u0131ndaki s\u0131ral\u0131 i\u015flemleri kontrol etme<\/li>\n<li><strong>Otomatik kap\u0131lar:<\/strong> G\u00fcvenlik ve verimlilik i\u00e7in a\u00e7ma ve kapama d\u00f6ng\u00fclerini d\u00fczenleyin<\/li>\n<li><strong>Otopark Bariyerleri:<\/strong> Zaman ayarl\u0131 bariyer operasyonlar\u0131 ile ara\u00e7 eri\u015fimini y\u00f6netin<\/li>\n<li><strong>Montaj Makineleri:<\/strong> Optimum verim i\u00e7in \u00fcretim hatt\u0131 zamanlamas\u0131n\u0131 koordine edin<\/li>\n<li><strong>Kompres\u00f6r Kontrolleri:<\/strong> Sistem bas\u0131nc\u0131n\u0131 korumak i\u00e7in s\u0131k\u0131\u015ft\u0131rma d\u00f6ng\u00fclerini d\u00fczenler<\/li>\n<li><strong>Ula\u015f\u0131m:<\/strong> Ula\u015f\u0131m sistemi bile\u015fenlerinin zaman tabanl\u0131 kontrol\u00fc<\/li>\n<li><strong>End\u00fcstriyel So\u011futma:<\/strong> Buz \u00e7\u00f6zme d\u00f6ng\u00fclerini ve so\u011futma i\u015flemlerini y\u00f6netin<\/li>\n<li><strong>Paketleme Makineleri:<\/strong> Tutarl\u0131 \u00fcr\u00fcn \u00e7\u0131kt\u0131s\u0131 i\u00e7in paketleme i\u015flemlerini senkronize edin<\/li>\n<li><strong>Pi\u015firme F\u0131r\u0131nlar\u0131:<\/strong> Tutarl\u0131 \u00fcr\u00fcn kalitesi i\u00e7in \u0131s\u0131tma d\u00f6ng\u00fclerini kontrol edin<\/li>\n<li><strong>Su ve At\u0131k Su:<\/strong> Ar\u0131tma s\u00fcreci zamanlamas\u0131n\u0131 ve pompa operasyonlar\u0131n\u0131 y\u00f6netme<\/li>\n<li><strong>R\u00fczgar Enerjisi:<\/strong> G\u00fcvenlik ve operasyonel sistemler i\u00e7in kontrol zamanlamas\u0131<\/li>\n<li><strong>End\u00fcstriyel Temizlik Prosesleri:<\/strong> Optimum performans i\u00e7in temizlik d\u00f6ng\u00fclerini planlay\u0131n<\/li>\n<\/ul>\n<h2>\u0130zleme ve Koruma \u00d6zellikleri<\/h2>\n<p>FCT18-A\/At zaman r\u00f6lesi, \u00e7al\u0131\u015fma ko\u015fullar\u0131n\u0131 izlemek ve tespit etmek i\u00e7in tasarlanm\u0131\u015f kapsaml\u0131 end\u00fcstriyel r\u00f6le serisinin bir par\u00e7as\u0131d\u0131r. \u0130zleme r\u00f6leleriyle entegre edildi\u011finde, FCT18-A\/At a\u015fa\u011f\u0131dakileri sa\u011flayan eksiksiz bir sistemin par\u00e7as\u0131 olabilir:<\/p>\n<h3>\u00dc\u00e7 Fazl\u0131 Gerilim \u0130zleme<\/h3>\n<ul>\n<li>Mobil \u00fc\u00e7 fazl\u0131 ekipman\u0131n gerilim izlemesi<\/li>\n<li>Personelin ve tesislerin faz de\u011fi\u015fimine kar\u015f\u0131 korunmas\u0131<\/li>\n<li>Makinelerin ve tesisatlar\u0131n besleme geriliminin izlenmesi<\/li>\n<li>Ekipman\u0131n dengesiz besleme geriliminin neden oldu\u011fu hasara kar\u015f\u0131 korunmas\u0131<\/li>\n<li>Acil durum veya yard\u0131mc\u0131 beslemeye ge\u00e7me<\/li>\n<\/ul>\n<h3>Tek Fazl\u0131 Ak\u0131m \u0130zleme<\/h3>\n<ul>\n<li>Motor ak\u0131m t\u00fcketiminin izlenmesi<\/li>\n<li>Ayd\u0131nlatma tesisatlar\u0131n\u0131n ve \u0131s\u0131tma devrelerinin izlenmesi<\/li>\n<li>Ta\u015f\u0131ma ekipmanlar\u0131n\u0131n a\u015f\u0131r\u0131 y\u00fcklenmesinin izlenmesi<\/li>\n<li>Kilitleme cihazlar\u0131n\u0131n, elektromekanik fren di\u015flilerinin ve kilitli rotorlar\u0131n izlenmesi<\/li>\n<\/ul>\n<h3>Tek Fazl\u0131 Gerilim \u0130zleme<\/h3>\n<ul>\n<li>DC motorlar\u0131n h\u0131z takibi<\/li>\n<li>Ak\u00fc voltajlar\u0131n\u0131n ve di\u011fer besleme a\u011flar\u0131n\u0131n izlenmesi<\/li>\n<\/ul>\n<h3>S\u0131v\u0131 Seviyesi \u0130zleme<\/h3>\n<ul>\n<li>Pompalar\u0131n kuru \u00e7al\u0131\u015fmaya kar\u015f\u0131 korunmas\u0131<\/li>\n<li>Konteyner ta\u015fmas\u0131na kar\u015f\u0131 koruma<\/li>\n<li>S\u0131v\u0131 seviyelerinin kontrol\u00fc<\/li>\n<li>S\u0131z\u0131nt\u0131lar\u0131n tespiti<\/li>\n<li>Kar\u0131\u015f\u0131m oranlar\u0131n\u0131n kontrol\u00fc<\/li>\n<\/ul>\n<h2>Kurulum Y\u00f6nergeleri<\/h2>\n<p>FCT18-A\/At zamanlay\u0131c\u0131 r\u00f6lenizin optimum performans\u0131 ve g\u00fcvenilirli\u011fi i\u00e7in bu kurulum y\u00f6nergelerini izleyin:<\/p>\n<ol>\n<li><strong>DIN Ray Montaj\u0131:<\/strong> R\u00f6leyi EN\/IEC 60715'e uygun olarak standart 35 mm DIN ray\u0131na sabitleyin.<\/li>\n<li><strong>\u00c7evresel Hususlar:<\/strong> Belirtilen s\u0131cakl\u0131k aral\u0131\u011f\u0131ndaki ortamlara kurun (-20\u00b0C ila +60\u00b0C \u00e7al\u0131\u015fma, -40\u00b0C ila +85\u00b0C depolama).<\/li>\n<li><strong>Kablolama:<\/strong> G\u00fcvenli ba\u011flant\u0131lar i\u00e7in uygun kablo boyutu (AWG13-20) kullan\u0131n ve uygun s\u0131y\u0131rma uzunlu\u011funu (7 mm) sa\u011flay\u0131n.<\/li>\n<li><strong>Kontrol Sinyali Yap\u0131land\u0131rmas\u0131:<\/strong> Kontrol sistemi gereksinimlerinize g\u00f6re NPN veya PNP \u00e7al\u0131\u015fmas\u0131 i\u00e7in yap\u0131land\u0131r\u0131n.<\/li>\n<li><strong>Zaman ve Oran Ayar\u0131:<\/strong> Sistem ba\u015flat\u0131lmadan \u00f6nce \u00f6n panel kontrollerini kullanarak istenen zaman aral\u0131\u011f\u0131n\u0131 ve oran\u0131 ayarlay\u0131n.<\/li>\n<li><strong>Bo\u015falt\u0131n:<\/strong> Havaland\u0131rma ve \u0131s\u0131 da\u011f\u0131l\u0131m\u0131 i\u00e7in r\u00f6lenin etraf\u0131nda yeterli alan b\u0131rak\u0131n.<\/li>\n<li><strong>Koruma:<\/strong> En az IP20 koruma sa\u011flayan bir kontrol paneline veya muhafazaya monte edin.<\/li>\n<\/ol>\n<h2>Neden VIOX FCT18-A\/At Zamanlay\u0131c\u0131 R\u00f6lesini Se\u00e7melisiniz?<\/h2>\n<p>VIOX FCT18-A\/At g\u00fc\u00e7 a\u00e7ma-geciktirme zaman r\u00f6lesi, ola\u011fan\u00fcst\u00fc \u00f6zellik kombinasyonu nedeniyle end\u00fcstriyel zamanlama uygulamalar\u0131 i\u00e7in ideal se\u00e7im olarak \u00f6ne \u00e7\u0131k\u0131yor:<\/p>\n<ul>\n<li><strong>Hassasiyet ve G\u00fcvenilirlik:<\/strong> FCT18-A\/At, 0,5%'den daha az zaman hatas\u0131 ve 0,5% tekrarlama do\u011frulu\u011fu ile kritik zamanlama uygulamalar\u0131 i\u00e7in tutarl\u0131 ve g\u00fcvenilir performans sunar.<\/li>\n<li><strong>\u00c7ok y\u00f6nl\u00fcl\u00fck:<\/strong> 0,1 saniye ile 100 g\u00fcn aras\u0131ndaki geni\u015f zaman aral\u0131\u011f\u0131, 20 oran ayar\u0131 ile birlikte \u00e7e\u015fitli uygulama gereksinimlerini kar\u015f\u0131lamak i\u00e7in benzersiz bir esneklik sa\u011flar.<\/li>\n<li><strong>Kullan\u0131m Kolayl\u0131\u011f\u0131:<\/strong> \u00dcr\u00fcn \u00fczerindeki kablo ba\u011flant\u0131 \u015femalar\u0131 ve net LED durum g\u00f6stergeleri ile basit yap\u0131land\u0131rma, kolay kurulum ve \u00e7al\u0131\u015ft\u0131rma sa\u011flar.<\/li>\n<li><strong>Dayan\u0131kl\u0131l\u0131k:<\/strong> FCT18-A\/At, 10 milyon i\u015flemlik mekanik \u00f6mr\u00fc ve 100.000 i\u015flemlik elektriksel \u00f6mr\u00fc ile ola\u011fan\u00fcst\u00fc uzun \u00f6m\u00fcr ve de\u011fer sunar.<\/li>\n<li><strong>Standartlara Uygunluk:<\/strong> GB\/T 14048.5, IEC60947-5-1 ve EN61812-1 standartlar\u0131na uygun olarak \u00fcretilmi\u015ftir, kalite ve uyumluluk sa\u011flar.<\/li>\n<li><strong>Kompakt Tasar\u0131m:<\/strong> Yer tasarrufu sa\u011flayan boyutlar\u0131 (90mm*18mm*64mm), kalabal\u0131k kontrol panellerine kurulum i\u00e7in idealdir.<\/li>\n<\/ul>\n<h2>Sonu\u00e7<\/h2>\n<p>VIOX FCT18-A\/At power on-delay timer r\u00f6lesi, end\u00fcstriyel zamanlama uygulamalar\u0131 i\u00e7in hassasiyet, \u00e7ok y\u00f6nl\u00fcl\u00fck ve g\u00fcvenilirli\u011fin m\u00fckemmel dengesini temsil eder. Basit motor ba\u015flatma dizilerinden karma\u015f\u0131k proses kontrol zamanlamas\u0131na kadar, bu kompakt ancak g\u00fc\u00e7l\u00fc r\u00f6le zorlu ortamlarda tutarl\u0131 performans sunar. Kapsaml\u0131 yap\u0131land\u0131rma se\u00e7enekleri, sa\u011flam yap\u0131s\u0131 ve standartlara uygun tasar\u0131m\u0131yla FCT18-A\/At, modern end\u00fcstriyel otomasyon sistemleri i\u00e7in ideal zamanlama kontrol \u00e7\u00f6z\u00fcm\u00fcd\u00fcr.<\/p>\n<p>VIOX FCT18-A\/At power on-delay timer relay hakk\u0131nda daha fazla bilgi almak veya \u00f6zel uygulama gereksinimlerinizi g\u00f6r\u00fc\u015fmek i\u00e7in l\u00fctfen teknik destek ekibimizle ileti\u015fime ge\u00e7in. End\u00fcstriyel kontrol ihtiya\u00e7lar\u0131n\u0131z i\u00e7in m\u00fckemmel zamanlama \u00e7\u00f6z\u00fcm\u00fcn\u00fc bulman\u0131za yard\u0131mc\u0131 olmaya kararl\u0131y\u0131z.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<div class=\"markdown\">\n<p>VIOX FCT18-A\/At Power On-Delay R\u00f6lesi, end\u00fcstriyel uygulamalar i\u00e7in hassas zamanlama kontrol\u00fc sunar. &lt;0,5% hata, yeniden tetikleme kontrol sinyali (NPN\/PNP) ve DIN ray montaj\u0131 ile geni\u015f bir zaman aral\u0131\u011f\u0131 (0,1s - 100 g\u00fcn) i\u00e7erir. Motor \u00e7al\u0131\u015ft\u0131rma, ayd\u0131nlatma kontrol\u00fc ve d\u00f6ng\u00fcsel anahtarlama i\u00e7in idealdir.<\/p>\n<\/div>","protected":false},"featured_media":14170,"comment_status":"closed","ping_status":"closed","template":"","meta":{"inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[],"product_cat":[123,196],"product_tag":[],"class_list":{"0":"post-14169","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-relay","7":"product_cat-time-relay","8":"desktop-align-left","9":"tablet-align-left","10":"mobile-align-left","12":"first","13":"instock","14":"shipping-taxable","15":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product\/14169","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/comments?post=14169"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/media\/14170"}],"wp:attachment":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/media?parent=14169"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product_brand?post=14169"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product_cat?post=14169"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product_tag?post=14169"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}