{"id":13921,"date":"2025-03-05T21:29:16","date_gmt":"2025-03-05T13:29:16","guid":{"rendered":"https:\/\/viox.com\/?post_type=product&#038;p=13921"},"modified":"2025-03-05T21:29:16","modified_gmt":"2025-03-05T13:29:16","slug":"vf003-miniature-circuit-breaker-mcb","status":"publish","type":"product","link":"https:\/\/test.viox.com\/tr\/urun\/vf003-miniature-circuit-breaker-mcb\/","title":{"rendered":"VF003 Minyat\u00fcr Devre Kesici (MCB)"},"content":{"rendered":"<div class=\"product-intro\">\n<h2>VIOX VF003 Minyat\u00fcr Devre Kesici nedir?<\/h2>\n<p>VF003, konut, ticari ve end\u00fcstriyel uygulamalarda kapsaml\u0131 elektrik korumas\u0131 i\u00e7in tasarlanm\u0131\u015f birinci s\u0131n\u0131f bir minyat\u00fcr devre kesicidir (MCB). Bu NF sertifikal\u0131 devre kesici, k\u0131sa devre ak\u0131mlar\u0131na, a\u015f\u0131r\u0131 y\u00fck ko\u015fullar\u0131na kar\u015f\u0131 g\u00fcvenilir koruma sa\u011flar ve elektrik da\u011f\u0131t\u0131m sistemlerinde etkili bir izolasyon anahtar\u0131 g\u00f6revi g\u00f6r\u00fcr.<\/p>\n<h2>Elektrik Tesisat\u0131n\u0131z i\u00e7in Neden VF003 MCB'yi Se\u00e7melisiniz?<\/h2>\n<p>G\u00fcn\u00fcm\u00fcz elektrik sistemlerinde g\u00fcvenlik ve g\u00fcvenilirlik her \u015feyden \u00f6nemlidir. VIOX VF003 minyat\u00fcr devre kesici, birden fazla sertifikaya (NF, UKCA, CE) ve ola\u011fan\u00fcst\u00fc performans \u00f6zelliklerine sahip \u00e7ok y\u00f6nl\u00fc bir koruma cihaz\u0131 olarak \u00f6ne \u00e7\u0131kar. \u0130ster ev tesisatlar\u0131 ister karma\u015f\u0131k end\u00fcstriyel sistemler \u00fczerinde \u00e7al\u0131\u015f\u0131yor olun, VF003 MCB modern elektrik \u015febekeleri i\u00e7in gereken koruma ve i\u015flevselli\u011fi sunar.<\/p>\n<h2>VF003 Minyat\u00fcr Devre Kesicinin Temel \u00d6zellikleri ve Faydalar\u0131<\/h2>\n<h3>\u00dcst\u00fcn Koruma Mekanizmas\u0131<\/h3>\n<p>VF003 MCB \u00e7ift koruma sistemine sahiptir:<\/p>\n<ul>\n<li><strong>Termal koruma<\/strong>: Uzun s\u00fcreli a\u015f\u0131r\u0131 y\u00fck ko\u015fullar\u0131na kar\u015f\u0131 koruma sa\u011flar<\/li>\n<li><strong>Manyetik koruma<\/strong>: K\u0131sa devre olaylar\u0131 s\u0131ras\u0131nda an\u0131nda a\u00e7ma sa\u011flar<\/li>\n<\/ul>\n<p>Bu kapsaml\u0131 koruma mekanizmas\u0131, elektrik sistemlerinizin \u00e7e\u015fitli ar\u0131za ko\u015fullar\u0131nda g\u00fcvende kalmas\u0131n\u0131 sa\u011flayarak ba\u011fl\u0131 ekipmanlar\u0131n hasar g\u00f6rmesini \u00f6nler ve yang\u0131n tehlikelerini azalt\u0131r.<\/p>\n<h3>\u00c7ok Y\u00f6nl\u00fc Ak\u0131m De\u011ferleri<\/h3>\n<p>VF003, \u00e7e\u015fitli uygulama gereksinimlerine uyacak \u015fekilde birden fazla ak\u0131m de\u011ferinde mevcuttur:<\/p>\n<ul>\n<li>2A, 6A, 10A, 16A, 20A, 25A ve 32A<\/li>\n<\/ul>\n<p>Bu seri, elektrik tasar\u0131mc\u0131lar\u0131n\u0131n ve tesisat\u00e7\u0131lar\u0131n belirli devre y\u00fckleri i\u00e7in gereken hassas derecelendirmeyi se\u00e7melerine olanak tan\u0131yarak gereksiz a\u00e7ma olmadan optimum koruma sa\u011flar.<\/p>\n<h3>\u00c7oklu Yolculuk E\u011frisi Se\u00e7enekleri<\/h3>\n<p>VF003 MCB, farkl\u0131 uygulama ihtiya\u00e7lar\u0131na g\u00f6re uyarlanm\u0131\u015f \u00f6zel a\u00e7ma e\u011frileri sunar:<\/p>\n<ul>\n<li><strong>B e\u011frisi (3-5In)<\/strong>: TN ve IT sistemlerinde insanlar\u0131 ve uzun kablo hatlar\u0131n\u0131 korumak i\u00e7in idealdir<\/li>\n<li><strong>C e\u011frisi (5-10In)<\/strong>: D\u00fc\u015f\u00fck ani ak\u0131m ile diren\u00e7li ve end\u00fcktif y\u00fckler i\u00e7in m\u00fckemmeldir<\/li>\n<li><strong>D e\u011frisi (10-14In)<\/strong>: Devre kapan\u0131rken y\u00fcksek ani ak\u0131m \u00e7eken y\u00fckleri besleyen devreler i\u00e7in tasarlanm\u0131\u015ft\u0131r (AG\/AG transformat\u00f6rleri, ar\u0131za lambalar\u0131)<\/li>\n<\/ul>\n<p>Bu \u00e7e\u015fitlilik, elektrik tesisat\u0131n\u0131z\u0131n belirli \u00f6zelliklerine g\u00f6re hassas koruma koordinasyonu sa\u011flar.<\/p>\n<h3>Y\u00fcksek K\u0131rma Kapasitesi<\/h3>\n<p>3000A, 4500A ve 6000A kesme kapasiteleri ile VF003 MCB, y\u00fcksek ar\u0131za ak\u0131mlar\u0131n\u0131 g\u00fcvenli bir \u015fekilde kesebilir ve zorlu end\u00fcstriyel ortamlarda bile sa\u011flam koruma sa\u011flar.<\/p>\n<h2>Teknik \u00d6zellikler: VF003 Minyat\u00fcr Devre Kesici<\/h2>\n<h3>Elektriksel \u00d6zellikler<\/h3>\n<table>\n<thead>\n<tr>\n<th>Parametre<\/th>\n<th>\u015eartname<\/th>\n<th>Standart<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Model No.<\/td>\n<td>VF003<\/td>\n<td>IEC\/EN 60898-1<\/td>\n<\/tr>\n<tr>\n<td>Kutuplar<\/td>\n<td>1P+N<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Nominal ak\u0131m Giri\u015f<\/td>\n<td>2A, 6A, 10A, 16A, 20A, 25A, 32A<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Nominal gerilim Ue<\/td>\n<td>120V, 230\/400V ~ 240\/415V<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Yal\u0131t\u0131m gerilimi Ui<\/td>\n<td>500V<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Nominal frekans<\/td>\n<td>50\/60 Hz<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Nominal kopma kapasitesi<\/td>\n<td>3000A, 4500A, 6000A<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Enerji s\u0131n\u0131rlama s\u0131n\u0131f\u0131<\/td>\n<td>3<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Nominal darbe dayan\u0131m gerilimi (1.2\/50) Uimp<\/td>\n<td>4000V<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Dielektrik test voltaj\u0131 ind. Frekans. 1 dakika i\u00e7in<\/td>\n<td>2Kv<\/td>\n<td>1.89kV<\/td>\n<\/tr>\n<tr>\n<td>Kirlilik derecesi<\/td>\n<td>2<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Termo-manyetik sal\u0131m \u00f6zelli\u011fi<\/td>\n<td>B, C<\/td>\n<td>(8 - 12) \u0130\u00e7inde<\/td>\n<\/tr>\n<tr>\n<td>Elektriksel \u00f6m\u00fcr<\/td>\n<td>10,000<\/td>\n<td><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Mekanik \u00d6zellikler<\/h3>\n<table>\n<thead>\n<tr>\n<th>Parametre<\/th>\n<th>\u015eartname<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Mekanik \u00f6m\u00fcr<\/td>\n<td>20.000 d\u00f6ng\u00fc<\/td>\n<\/tr>\n<tr>\n<td>Kontak konum g\u00f6stergesi<\/td>\n<td>Evet<\/td>\n<\/tr>\n<tr>\n<td>Koruma derecesi<\/td>\n<td>IP20<\/td>\n<\/tr>\n<tr>\n<td>Termal eleman ayar\u0131 i\u00e7in referans s\u0131cakl\u0131k<\/td>\n<td>30\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Ortam s\u0131cakl\u0131\u011f\u0131 (g\u00fcnl\u00fck ortalama\u226435\u00b0C)<\/td>\n<td>-5\u00b0C ila 40\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Depolama s\u0131cakl\u0131\u011f\u0131<\/td>\n<td>-25\u00b0C ila 70\u00b0C<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Kurulum \u00d6zellikleri<\/h3>\n<table>\n<thead>\n<tr>\n<th>Parametre<\/th>\n<th>\u015eartname<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Terminal ba\u011flant\u0131 tipi<\/td>\n<td>Kablo\/U-tipi bara\/Pin-tipi bara<\/td>\n<\/tr>\n<tr>\n<td>Kablo i\u00e7in \u00fcst\/alt terminal boyutu<\/td>\n<td>25 mm\u00b2 \/ 18-4 AWG<\/td>\n<\/tr>\n<tr>\n<td>Bara i\u00e7in \u00fcst\/alt terminal boyutu<\/td>\n<td>10 mm\u00b2 \/ 18-8 AWG<\/td>\n<\/tr>\n<tr>\n<td>S\u0131kma torku<\/td>\n<td>2,5 N-m \/ 22 In-lbs.<\/td>\n<\/tr>\n<tr>\n<td>Montaj<\/td>\n<td>H\u0131zl\u0131 klips cihaz\u0131 ile DIN ray\u0131 EN 60715 (35mm) \u00fczerinde<\/td>\n<\/tr>\n<tr>\n<td>Ba\u011flant\u0131<\/td>\n<td>Yukar\u0131dan ve a\u015fa\u011f\u0131dan<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Aksesuar Uyumlulu\u011fu<\/h3>\n<table>\n<thead>\n<tr>\n<th>\u00d6zellik<\/th>\n<th>Kullan\u0131labilirlik<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Yard\u0131mc\u0131 kontak<\/td>\n<td>Evet<\/td>\n<\/tr>\n<tr>\n<td>\u015e\u00f6nt serbest b\u0131rakma<\/td>\n<td>Evet<\/td>\n<\/tr>\n<tr>\n<td>Gerilim alt\u0131nda b\u0131rakma<\/td>\n<td>Evet<\/td>\n<\/tr>\n<tr>\n<td>Alarm konta\u011f\u0131<\/td>\n<td>Evet<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>VF003 Minyat\u00fcr Devre Kesici Uygulamalar\u0131<\/h2>\n<h3>Konut Elektrik Sistemleri<\/h3>\n<p>VF003 MCB, ev elektrik tesisatlar\u0131 i\u00e7in m\u00fckemmeldir ve \u015funlar\u0131 sa\u011flar:<\/p>\n<ul>\n<li>Ayd\u0131nlatma devreleri i\u00e7in koruma<\/li>\n<li>Elektrik prizleri i\u00e7in g\u00fcvenlik<\/li>\n<li>Ev aletleri i\u00e7in a\u015f\u0131r\u0131 y\u00fck korumas\u0131<\/li>\n<li>Ev tesisat\u0131 i\u00e7in k\u0131sa devre korumas\u0131<\/li>\n<\/ul>\n<h3>Ticari Binalar<\/h3>\n<p>Ticari ortamlarda VF003 \u015funlar\u0131 sunar:<\/p>\n<ul>\n<li>Ofis ekipmanlar\u0131 i\u00e7in g\u00fcvenilir koruma<\/li>\n<li>Ayd\u0131nlatma sistemleri i\u00e7in g\u00fcvenlik<\/li>\n<li>HVAC sistemleri i\u00e7in g\u00fcvenlik<\/li>\n<li>Hassas elektronik ekipman i\u00e7in koruma<\/li>\n<\/ul>\n<h3>End\u00fcstriyel Uygulamalar<\/h3>\n<p>End\u00fcstriyel ortamlar i\u00e7in VF003 \u015funlar\u0131 sa\u011flar:<\/p>\n<ul>\n<li>Motor korumas\u0131 (uygun de\u011fer se\u00e7imi ile)<\/li>\n<li>Kontrol devresi korumas\u0131<\/li>\n<li>Da\u011f\u0131t\u0131m panosu g\u00fcvenli\u011fi<\/li>\n<li>Ekipman izolasyon kabiliyeti<\/li>\n<\/ul>\n<h2>VF003 MCB i\u00e7in Se\u00e7im Y\u00f6nergeleri<\/h2>\n<h3>Do\u011fru Ak\u0131m De\u011feri Nas\u0131l Se\u00e7ilir?<\/h3>\n<ol>\n<li><strong>Y\u00fck ak\u0131m\u0131n\u0131 hesaplay\u0131n<\/strong>: Devrenizin ta\u015f\u0131yaca\u011f\u0131 maksimum s\u00fcrekli ak\u0131m\u0131 belirleyin<\/li>\n<li><strong>G\u00fcvenlik fakt\u00f6r\u00fc uygulay\u0131n<\/strong>: Hesaplanan y\u00fck ak\u0131m\u0131ndan yakla\u015f\u0131k 25% daha y\u00fcksek bir MCB de\u011feri se\u00e7in<\/li>\n<li><strong>Ba\u015flang\u0131\u00e7 ak\u0131mlar\u0131n\u0131 g\u00f6z \u00f6n\u00fcnde bulundurun<\/strong>: Motorlar ve di\u011fer y\u00fcksek anaforlu ekipmanlar i\u00e7in, ba\u015flang\u0131\u00e7 ak\u0131m\u0131n\u0131 hesaba kat\u0131n<\/li>\n<li><strong>Kablo de\u011ferlerini kontrol edin<\/strong>: Se\u00e7ilen MCB de\u011ferinin kurulu kablo boyutu ile uyumlu oldu\u011fundan emin olun<\/li>\n<\/ol>\n<h3>Uygun Yolculuk E\u011frisi Nas\u0131l Se\u00e7ilir<\/h3>\n<ul>\n<li><strong>B e\u011frisi<\/strong>: Konut ayd\u0131nlatmas\u0131, prizler ve genel ama\u00e7l\u0131 devreler i\u00e7in se\u00e7in<\/li>\n<li><strong>C e\u011frisi<\/strong>: K\u00fc\u00e7\u00fck transformat\u00f6rler, floresan ayd\u0131nlatma ve standart motorlar i\u00e7in se\u00e7in<\/li>\n<li><strong>D e\u011frisi<\/strong>: Transformat\u00f6rler, y\u00fcksek ba\u015flang\u0131\u00e7 ak\u0131m\u0131na sahip motorlar ve kaynak ekipmanlar\u0131 i\u00e7in kullan\u0131n<\/li>\n<\/ul>\n<h3>K\u0131rma Kapasitesi Se\u00e7imi<\/h3>\n<p>VF003'\u00fcn kesme kapasitesi her zaman kurulum noktas\u0131ndaki maksimum potansiyel k\u0131sa devre ak\u0131m\u0131n\u0131 a\u015fmal\u0131d\u0131r. Dikkate al\u0131n:<\/p>\n<ol>\n<li><strong>Kurulum yeri<\/strong>: Ana da\u011f\u0131t\u0131m panosuna yak\u0131nl\u0131k<\/li>\n<li><strong>Besleme transformat\u00f6r\u00fc boyutu<\/strong>: Daha b\u00fcy\u00fck transformat\u00f6rler daha y\u00fcksek ar\u0131za ak\u0131mlar\u0131 sa\u011flayabilir<\/li>\n<li><strong>Kablo empedans\u0131<\/strong>: Daha uzun kablo hatlar\u0131 mevcut ar\u0131za ak\u0131m\u0131n\u0131 azalt\u0131r<\/li>\n<\/ol>\n<h2>VF003 MCB i\u00e7in En \u0130yi Kurulum Uygulamalar\u0131<\/h2>\n<h3>Montaj Talimatlar\u0131<\/h3>\n<ol>\n<li>VF003, entegre h\u0131zl\u0131 klips cihaz\u0131n\u0131 kullanarak standart 35 mm DIN raylar\u0131na (EN 60715) g\u00fcvenli bir \u015fekilde monte edilir<\/li>\n<li>Uygun \u0131s\u0131 da\u011f\u0131l\u0131m\u0131 i\u00e7in MCB'nin etraf\u0131nda yeterli alan oldu\u011fundan emin olun<\/li>\n<li>ON\/OFF i\u015faretleri do\u011fru \u015fekilde y\u00f6nlendirilmi\u015f olarak dikey konumda monte edin<\/li>\n<li>Kurulum k\u0131lavuzlar\u0131nda belirtilen minimum a\u00e7\u0131kl\u0131klar\u0131 koruyun<\/li>\n<\/ol>\n<h3>Kablolama Y\u00f6nergeleri<\/h3>\n<ol>\n<li>Uygun kablo boyutunu kullan\u0131n (en fazla 25 mm\u00b2 veya 18-4 AWG)<\/li>\n<li>Terminal vidalar\u0131n\u0131 belirtilen torkla s\u0131k\u0131n (2,5 N-m veya 22 In-lbs)<\/li>\n<li>Yerle\u015ftirmeden \u00f6nce iletkenleri do\u011fru uzunlukta soyun<\/li>\n<li>Enerji vermeden \u00f6nce t\u00fcm ba\u011flant\u0131lar\u0131n sa\u011flam oldu\u011funu kontrol edin<\/li>\n<\/ol>\n<h3>Test ve Devreye Alma<\/h3>\n<ol>\n<li>Do\u011fru montaj ve ba\u011flant\u0131 i\u00e7in kurulumu g\u00f6rsel olarak inceleyin<\/li>\n<li>Manuel anahtar mekanizmas\u0131n\u0131n \u00e7al\u0131\u015fmas\u0131n\u0131 test edin<\/li>\n<li>A\u00e7\u0131k kontaklar aras\u0131nda \u00f6l\u00e7\u00fcm yaparak izolasyon i\u015flevini do\u011frulay\u0131n<\/li>\n<li>A\u00e7ma fonksiyonunu uygun test ekipman\u0131 kullanarak test edin<\/li>\n<\/ol>\n<h2>Bak\u0131m ve Sorun Giderme<\/h2>\n<h3>D\u00fczenli Bak\u0131m Kontrolleri<\/h3>\n<ol>\n<li><strong>G\u00f6rsel inceleme<\/strong>: A\u015f\u0131r\u0131 \u0131s\u0131nma veya hasar belirtisi olup olmad\u0131\u011f\u0131n\u0131 kontrol edin<\/li>\n<li><strong>Manuel \u00e7al\u0131\u015fma testi<\/strong>: Sorunsuz \u00e7al\u0131\u015fmay\u0131 sa\u011flamak i\u00e7in anahtar\u0131 periyodik olarak de\u011fi\u015ftirin<\/li>\n<li><strong>Terminal s\u0131k\u0131l\u0131\u011f\u0131<\/strong>: T\u00fcm ba\u011flant\u0131lar\u0131n g\u00fcvenli kald\u0131\u011f\u0131n\u0131 do\u011frulay\u0131n<\/li>\n<li><strong>\u0130zolasyon direnci<\/strong>: A\u00e7\u0131k kontaklar boyunca yal\u0131t\u0131m direncini periyodik olarak \u00f6l\u00e7\u00fcn<\/li>\n<\/ol>\n<h3>Yayg\u0131n Sorunlar ve \u00c7\u00f6z\u00fcmler<\/h3>\n<table>\n<thead>\n<tr>\n<th>Sorun<\/th>\n<th>Olas\u0131 Sebep<\/th>\n<th>\u00c7\u00f6z\u00fcm<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>S\u0131k s\u0131k a\u00e7ma<\/td>\n<td>A\u015f\u0131r\u0131 y\u00fcklenmi\u015f devre<\/td>\n<td>Y\u00fck\u00fc azalt\u0131n veya daha y\u00fcksek dereceli MCB tak\u0131n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>K\u0131sa devre<\/td>\n<td>Ar\u0131zan\u0131n tan\u0131mlanmas\u0131 ve onar\u0131lmas\u0131<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>S\u0131k\u0131nt\u0131 a\u00e7ma<\/td>\n<td>Daha uygun bir yolculuk e\u011frisine ge\u00e7meyi d\u00fc\u015f\u00fcn\u00fcn<\/td>\n<\/tr>\n<tr>\n<td>MCB s\u0131f\u0131rlanm\u0131yor<\/td>\n<td>Kal\u0131c\u0131 ar\u0131za<\/td>\n<td>S\u0131f\u0131rlamadan \u00f6nce ar\u0131zan\u0131n yerini belirleyin ve giderin<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Mekanik hasar<\/td>\n<td>MCB'yi de\u011fi\u015ftirin<\/td>\n<\/tr>\n<tr>\n<td>A\u015f\u0131r\u0131 \u0131s\u0131nma<\/td>\n<td>Gev\u015fek ba\u011flant\u0131lar<\/td>\n<td>Terminalleri belirtilen torkla s\u0131k\u0131n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>A\u015f\u0131r\u0131 Y\u00fck<\/td>\n<td>Devre y\u00fck\u00fcn\u00fc azalt\u0131n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Standartlar ve Sertifikalar<\/h2>\n<p>VF003 minyat\u00fcr devre kesici bir\u00e7ok uluslararas\u0131 standartla uyumludur:<\/p>\n<ul>\n<li><strong>IEC\/EN 60898-1<\/strong>: MCB'ler i\u00e7in uluslararas\u0131 standart<\/li>\n<li><strong>NF sertifikas\u0131<\/strong>: Frans\u0131z kalite ve g\u00fcvenlik standard\u0131<\/li>\n<li><strong>UKCA onay\u0131<\/strong>: Birle\u015fik Krall\u0131k Uygunluk De\u011ferlendirmesi i\u015fareti<\/li>\n<li><strong>CE i\u015fareti<\/strong>: Avrupa uygunluk sertifikas\u0131<\/li>\n<\/ul>\n<p>Bu sertifikalar, VF003'\u00fcn elektrikli koruma cihazlar\u0131na y\u00f6nelik kat\u0131 kalite ve g\u00fcvenlik gereksinimlerini kar\u015f\u0131lamas\u0131n\u0131 sa\u011flar.<\/p>\n<h2>\u00c7evresel Hususlar<\/h2>\n<h3>\u00c7al\u0131\u015fma Ko\u015fullar\u0131<\/h3>\n<p>VF003 MCB a\u015fa\u011f\u0131daki ko\u015fullar alt\u0131nda g\u00fcvenilir \u015fekilde \u00e7al\u0131\u015facak \u015fekilde tasarlanm\u0131\u015ft\u0131r:<\/p>\n<ul>\n<li>Ortam s\u0131cakl\u0131\u011f\u0131 aral\u0131\u011f\u0131: -5\u00b0C ila 40\u00b0C (g\u00fcnl\u00fck ortalama \u226435\u00b0C)<\/li>\n<li>Depolama s\u0131cakl\u0131\u011f\u0131 aral\u0131\u011f\u0131: -25\u00b0C ila 70\u00b0C<\/li>\n<li>Kirlilik derecesi: 2<\/li>\n<li>Koruma derecesi: IP20<\/li>\n<\/ul>\n<h3>\u00c7evresel Etki<\/h3>\n<p>Modern elektrik tesisatlar\u0131nda \u00e7evresel fakt\u00f6rler giderek daha fazla dikkate al\u0131nmaktad\u0131r:<\/p>\n<ul>\n<li>VF003'\u00fcn uzun mekanik ve elektriksel \u00f6mr\u00fc (s\u0131ras\u0131yla 20.000 ve 10.000 d\u00f6ng\u00fc) de\u011fi\u015ftirme israf\u0131n\u0131 azalt\u0131r<\/li>\n<li>Enerji s\u0131n\u0131rlama s\u0131n\u0131f\u0131 3 sertifikas\u0131 enerji tasarruflu tesislere katk\u0131da bulunur<\/li>\n<li>RoHS ve di\u011fer \u00e7evre direktiflerine uygunluk, minimum \u00e7evresel etki sa\u011flar<\/li>\n<\/ul>\n<h2>Geli\u015fmi\u015f \u0130\u015flevsellik i\u00e7in Aksesuar Se\u00e7enekleri<\/h2>\n<p>VF003 MCB, i\u015flevselli\u011fini art\u0131rmak i\u00e7in \u00e7e\u015fitli aksesuarlarla tamamlanabilir:<\/p>\n<ol>\n<li><strong>Yard\u0131mc\u0131 kontaklar<\/strong>: Durum izleme ve bina y\u00f6netim sistemleri ile entegrasyon i\u00e7in<\/li>\n<li><strong>\u015e\u00f6nt serbest b\u0131rakma<\/strong>: Acil kapatma i\u00e7in uzaktan a\u00e7ma \u00f6zelli\u011fi<\/li>\n<li><strong>Gerilim alt\u0131nda b\u0131rakma<\/strong>: Gerilim d\u00fc\u015f\u00fc\u015fleri s\u0131ras\u0131nda otomatik ba\u011flant\u0131 kesme<\/li>\n<li><strong>Alarm kontaklar\u0131<\/strong>: Yolculuk olaylar\u0131n\u0131n uzaktan g\u00f6sterilmesi i\u00e7in<\/li>\n<\/ol>\n<p>Bu aksesuarlar VF003'\u00fcn \u00e7ok y\u00f6nl\u00fcl\u00fc\u011f\u00fcn\u00fc art\u0131rarak modern ak\u0131ll\u0131 bina sistemlerine entegrasyon sa\u011flar.<\/p>\n<h2>Sonu\u00e7: VF003 MCB Neden Do\u011fru Se\u00e7imdir?<\/h2>\n<p>VIOX VF003 minyat\u00fcr devre kesici, \u00fcst\u00fcn koruma \u00f6zelliklerini \u00e7ok y\u00f6nl\u00fc yap\u0131land\u0131rma se\u00e7enekleriyle birle\u015ftirerek neredeyse t\u00fcm elektrik tesisat\u0131 gereksinimleri i\u00e7in uygun hale getirir. NF sertifikas\u0131, \u00e7oklu a\u00e7ma e\u011frisi se\u00e7enekleri ve kapsaml\u0131 ak\u0131m de\u011ferleri yelpazesi ile VF003 g\u00fcvenilir, emniyetli ve verimli devre korumas\u0131 sa\u011flar.<\/p>\n<p>\u0130ster basit bir konut tesisat\u0131 ister karma\u015f\u0131k bir end\u00fcstriyel sistem \u00fczerinde \u00e7al\u0131\u015f\u0131yor olun, VF003 MCB g\u00fcn\u00fcm\u00fcz\u00fcn zorlu elektrik ortamlar\u0131 i\u00e7in gereken performans\u0131, g\u00fcvenilirli\u011fi ve g\u00fcvenlik \u00f6zelliklerini sa\u011flar.<\/p>\n<p>VF003 minyat\u00fcr devre kesici hakk\u0131nda daha fazla bilgi almak veya di\u011fer VIOX elektrik koruma \u00e7\u00f6z\u00fcmlerini ke\u015ffetmek i\u00e7in teknik destek ekibimizle ileti\u015fime ge\u00e7in veya viox.com adresindeki web sitemizi ziyaret edin.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<div class=\"markdown\">\n<p>VIOX VF003 Minyat\u00fcr Devre Kesici (MCB) konut, ticari ve end\u00fcstriyel uygulamalar i\u00e7in kapsaml\u0131 a\u015f\u0131r\u0131 y\u00fck ve k\u0131sa devre korumas\u0131 sa\u011flar. NF, UKCA ve CE sertifikal\u0131 bu 1P+N MCB, 32A'e kadar ak\u0131m de\u011ferleri ile B, C ve D a\u00e7ma e\u011frileri sunar. 3000A, 4500A ve 6000A kesme kapasiteleri.<\/p>\n<\/div>","protected":false},"featured_media":13922,"comment_status":"closed","ping_status":"closed","template":"","meta":{"inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[],"product_cat":[130],"product_tag":[],"class_list":{"0":"post-13921","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-mcb","7":"desktop-align-left","8":"tablet-align-left","9":"mobile-align-left","11":"first","12":"instock","13":"shipping-taxable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product\/13921","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/comments?post=13921"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/media\/13922"}],"wp:attachment":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/media?parent=13921"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product_brand?post=13921"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product_cat?post=13921"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product_tag?post=13921"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}