{"id":13916,"date":"2025-03-05T21:01:25","date_gmt":"2025-03-05T13:01:25","guid":{"rendered":"https:\/\/viox.com\/?post_type=product&#038;p=13916"},"modified":"2025-03-05T21:01:25","modified_gmt":"2025-03-05T13:01:25","slug":"vml01-2p-residual-current-operated-circuit-breaker-rccb","status":"publish","type":"product","link":"https:\/\/test.viox.com\/tr\/urun\/vml01-2p-residual-current-operated-circuit-breaker-rccb\/","title":{"rendered":"VML01 2P Art\u0131k Ak\u0131mla \u00c7al\u0131\u015fan Devre Kesici (RCCB)"},"content":{"rendered":"<div class=\"product-intro\">\n<h2>1. VML01 RCCB'ye Giri\u015f<\/h2>\n<p>VML01 Ka\u00e7ak Ak\u0131m Devre Kesici (RCCB), konutlarda, ticari ve end\u00fcstriyel uygulamalarda elektrik tehlikelerine kar\u015f\u0131 kapsaml\u0131 koruma sa\u011flamak i\u00e7in tasarlanm\u0131\u015f elektrik g\u00fcvenli\u011fi teknolojisinin zirvesini temsil eder. Bu IEC\/EN 61008-1 uyumlu cihaz, yang\u0131n tehlikesine yol a\u00e7abilecek dolayl\u0131 temas, do\u011frudan temas ve yal\u0131t\u0131m hatalar\u0131ndan kaynaklanan elektrik \u00e7arpmas\u0131na kar\u015f\u0131 \u00fcst\u00fcn koruma sa\u011flar.<\/p>\n<p>Manyetik tip art\u0131k ak\u0131mla \u00e7al\u0131\u015fan bir devre kesici olan VML01 RCCB, bir elektrik devresindeki canl\u0131 iletkenler ve n\u00f6tr \u00fczerinden akan ak\u0131m dengesini s\u00fcrekli olarak izler. Hassasiyet e\u015fi\u011fini a\u015fan bir topra\u011fa ak\u0131m ka\u00e7a\u011f\u0131 tespit etti\u011finde, devre ba\u011flant\u0131s\u0131n\u0131 h\u0131zla keserek potansiyel olarak hayati tehlike olu\u015fturan durumlar\u0131 \u00f6nler.<\/p>\n<h2>2. VML01 RCCB'nin Temel \u0130\u015flevleri ve Uygulamalar\u0131<\/h2>\n<h3>2.1 Birincil \u0130\u015flevler<\/h3>\n<ul>\n<li><strong>Elektrik Devre Kontrol\u00fc:<\/strong> Elektrik devrelerinin g\u00fcvenilir y\u00f6netimini sa\u011flar<\/li>\n<li><strong>Ki\u015fisel Koruma:<\/strong> Dolayl\u0131 temaslara kar\u015f\u0131 korur ve do\u011frudan temaslara kar\u015f\u0131 ek koruma sa\u011flar<\/li>\n<li><strong>Yang\u0131n Tehlikesi \u00d6nleme:<\/strong> Tesisatlar\u0131 yal\u0131t\u0131m hatalar\u0131ndan kaynaklanan yang\u0131n risklerine kar\u015f\u0131 korur<\/li>\n<\/ul>\n<h3>2.2 Uygulama Sekt\u00f6rleri<\/h3>\n<p>VML01 RCCB, birden fazla ortamda temel g\u00fcvenlik sa\u011flar:<\/p>\n<ul>\n<li><strong>Konut Ayarlar\u0131:<\/strong> Evlerin ve ya\u015fam alanlar\u0131n\u0131n korunmas\u0131<\/li>\n<li><strong>\u00dc\u00e7\u00fcnc\u00fcl Sekt\u00f6r:<\/strong> Ticari binalarda, ofislerde ve kamu tesislerinde g\u00fcvenli\u011fin sa\u011flanmas\u0131<\/li>\n<li><strong>End\u00fcstriyel Ortamlar:<\/strong> \u00dcretim tesislerinin ve \u00fcretim tesislerinin korunmas\u0131<\/li>\n<\/ul>\n<h3>2.3 Uzmanla\u015fm\u0131\u015f Uygulamalar<\/h3>\n<p>\u00c7oklu hassasiyet se\u00e7enekleri ile VML01 RCCB a\u015fa\u011f\u0131dakiler i\u00e7in m\u00fckemmel \u015fekilde uygundur:<\/p>\n<ul>\n<li><strong>Hassas Alet Korumas\u0131:<\/strong> 10mA hassasiyet laboratuvar ekipmanlar\u0131 ve banyolar i\u00e7in idealdir<\/li>\n<li><strong>Geli\u015ftirilmi\u015f Ki\u015fisel G\u00fcvenlik:<\/strong> Do\u011frudan temasa kar\u015f\u0131 ek koruma sa\u011flayan 30mA hassasiyet<\/li>\n<li><strong>D\u00fcnya Sistemi Koordinasyonu:<\/strong> I\u00b2n &lt; 50\/R form\u00fcl\u00fcne g\u00f6re topraklama sistemleri ile \u00e7al\u0131\u015fan 100mA hassasiyet<\/li>\n<li><strong>Yang\u0131n Tehlikesi \u00d6nleme:<\/strong> Hem dolayl\u0131 temaslara hem de yang\u0131n risklerine kar\u015f\u0131 koruma sa\u011flayan 300mA\/500mA hassasiyet<\/li>\n<\/ul>\n<h2>3. VML01 RCCB Teknik \u00d6zellikleri<\/h2>\n<h3>3.1 Elektriksel \u00d6zellikler<\/h3>\n<table border=\"1\" cellspacing=\"0\" cellpadding=\"5\">\n<tbody>\n<tr>\n<th>Parametre<\/th>\n<th>\u015eartname<\/th>\n<\/tr>\n<tr>\n<td>Model No.<\/td>\n<td>VML01<\/td>\n<\/tr>\n<tr>\n<td>Kutuplar<\/td>\n<td>2P, 4P<\/td>\n<\/tr>\n<tr>\n<td>Nominal ak\u0131m Giri\u015f<\/td>\n<td>16A, 25A, 32A, 40A, 63A, 80A, 100A<\/td>\n<\/tr>\n<tr>\n<td>Nominal Hassasiyet I\u25b3n<\/td>\n<td>10mA (2P\/4P 16A-40A), 30mA, 100mA, 300mA<\/td>\n<\/tr>\n<tr>\n<td>Nominal gerilim Ue<\/td>\n<td>2P: 240V 4P: 415V<\/td>\n<\/tr>\n<tr>\n<td>Yal\u0131t\u0131m gerilimi Ui<\/td>\n<td>500V<\/td>\n<\/tr>\n<tr>\n<td>Nominal frekans<\/td>\n<td>50\/60 Hz<\/td>\n<\/tr>\n<tr>\n<td>Nominal art\u0131k olu\u015fturma ve k\u0131rma kapasitesi I\u25b3m<\/td>\n<td>1500A<\/td>\n<\/tr>\n<tr>\n<td>K\u0131sa devre ak\u0131m\u0131 Inc=I\u25b3c<\/td>\n<td>6000A, 10000A<\/td>\n<\/tr>\n<tr>\n<td>Tip (alg\u0131lanan toprak ka\u00e7a\u011f\u0131n\u0131n dalga formu)<\/td>\n<td>AC, A<\/td>\n<\/tr>\n<tr>\n<td>A\u00e7\u0131lma s\u00fcresi<\/td>\n<td>Anl\u0131k, K\u0131sa zaman gecikmeli, Se\u00e7ici<\/td>\n<\/tr>\n<tr>\n<td>I\u25b3n alt\u0131nda mola s\u00fcresi<\/td>\n<td>&lt;0,1s (Normal tip), 10ms-300ms (ASi, G, KV tipi), 150ms-500ms (S tipi)<\/td>\n<\/tr>\n<tr>\n<td>Nominal darbe dayan\u0131m gerilimi (1.2\/50) Uimp<\/td>\n<td>6kV<\/td>\n<\/tr>\n<tr>\n<td>Dielektrik test voltaj\u0131 ind. Frekans. 1 dakika i\u00e7in<\/td>\n<td>2.5<\/td>\n<\/tr>\n<tr>\n<td>Kirlilik derecesi<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td>Elektriksel \u00f6m\u00fcr<\/td>\n<td>\u22652000<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>3.2 Mekanik \u00d6zellikler<\/h3>\n<table border=\"1\" cellspacing=\"0\" cellpadding=\"5\">\n<tbody>\n<tr>\n<th>Parametre<\/th>\n<th>\u015eartname<\/th>\n<\/tr>\n<tr>\n<td>Mekanik \u00f6m\u00fcr<\/td>\n<td>\u22652000<\/td>\n<\/tr>\n<tr>\n<td>Ar\u0131za ak\u0131m g\u00f6stergesi<\/td>\n<td>Evet<\/td>\n<\/tr>\n<tr>\n<td>Terminal koruma derecesi<\/td>\n<td>IP20<\/td>\n<\/tr>\n<tr>\n<td>Ortam s\u0131cakl\u0131\u011f\u0131 (g\u00fcnl\u00fck ortalama \u226435\u00b0C)<\/td>\n<td>-25\u00b0C ila 55\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Depolama s\u0131cakl\u0131\u011f\u0131<\/td>\n<td>-40\u00b0C ila 70\u00b0C<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>3.3 Kurulum Parametreleri<\/h3>\n<table border=\"1\" cellspacing=\"0\" cellpadding=\"5\">\n<tbody>\n<tr>\n<th>Parametre<\/th>\n<th>\u015eartname<\/th>\n<\/tr>\n<tr>\n<td>Terminal ba\u011flant\u0131 tipi<\/td>\n<td>Kablo\/Pim tipi bara<\/td>\n<\/tr>\n<tr>\n<td>Kablo i\u00e7in \u00fcst\/alt terminal boyutu<\/td>\n<td>25-35 mm\u00b2 \/ 18-3\/18-2 AWG<\/td>\n<\/tr>\n<tr>\n<td>Bara i\u00e7in \u00fcst\/alt terminal boyutu<\/td>\n<td>10\/16 mm\u00b2 \/ 18-8\/18-5 AWG<\/td>\n<\/tr>\n<tr>\n<td>S\u0131kma torku<\/td>\n<td>2,5 N-m \/ 22 in-lbs.<\/td>\n<\/tr>\n<tr>\n<td>Montaj<\/td>\n<td>H\u0131zl\u0131 klips cihaz\u0131 ile DIN ray\u0131 EN 60715 (35mm) \u00fczerinde<\/td>\n<\/tr>\n<tr>\n<td>Ba\u011flant\u0131<\/td>\n<td>Yukar\u0131dan ve a\u015fa\u011f\u0131dan<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>4. VML01 RCCB'nin Geli\u015fmi\u015f Koruma \u00d6zellikleri<\/h2>\n<h3>4.1 A\u00e7ma Hassasiyeti Se\u00e7enekleri<\/h3>\n<p>VML01 RCCB, farkl\u0131 koruma gereksinimlerini kar\u015f\u0131lamak i\u00e7in \u00e7oklu hassasiyet e\u015fikleri sunar:<\/p>\n<ul>\n<li><strong>10mA:<\/strong> Banyo tesisatlar\u0131 i\u00e7in hassas cihaz s\u0131z\u0131nt\u0131 korumas\u0131 ve geli\u015fmi\u015f g\u00fcvenlik sa\u011flar<\/li>\n<li><strong>30mA:<\/strong> Do\u011frudan temasa kar\u015f\u0131 ek koruma sa\u011flar, genel konut devreleri i\u00e7in idealdir<\/li>\n<li><strong>100mA:<\/strong> Dolayl\u0131 temaslara kar\u015f\u0131 koruma sa\u011flayan I\u00b2n &lt; 50\/R form\u00fcl\u00fcne g\u00f6re toprak sistemi ile koordinasyon sa\u011flar<\/li>\n<li><strong>300mA\/500mA:<\/strong> Dolayl\u0131 temaslara ve yang\u0131n tehlikelerine kar\u015f\u0131 koruma sa\u011flayarak end\u00fcstriyel uygulamalar i\u00e7in uygun hale getirir<\/li>\n<\/ul>\n<h3>4.2 A\u00e7ma S\u00fcresi S\u0131n\u0131fland\u0131rmalar\u0131<\/h3>\n<p>VML01 RCCB, \u00e7e\u015fitli koruma stratejilerine uyacak \u00fc\u00e7 farkl\u0131 a\u00e7ma s\u00fcresi se\u00e7ene\u011fine sahiptir:<\/p>\n<ul>\n<li><strong>Anl\u0131k:<\/strong> Zaman gecikmesi olmadan an\u0131nda a\u00e7ma sa\u011flayarak koruma h\u0131z\u0131n\u0131 en \u00fcst d\u00fczeye \u00e7\u0131kar\u0131r<\/li>\n<li><strong>K\u0131sa zaman gecikmesi (ASi, G, KV):<\/strong> En az 10 ms i\u00e7inde a\u00e7may\u0131 garanti eder, korumay\u0131 operasyonel kararl\u0131l\u0131kla dengeler<\/li>\n<li><strong>Se\u00e7ici (S):<\/strong> A\u015fa\u011f\u0131 y\u00f6nde yerle\u015ftirilen se\u00e7ici olmayan RCD'lerle toplam ayr\u0131mc\u0131l\u0131k sa\u011flayarak \u00e7ok seviyeli kurulumlarda koordineli koruma sa\u011flar<\/li>\n<\/ul>\n<h3>4.3 Alg\u0131lanabilir Dalga Formu S\u0131n\u0131fland\u0131rmalar\u0131<\/h3>\n<p>VML01 RCCB, farkl\u0131 ka\u00e7ak ak\u0131m profillerine hitap etmek i\u00e7in \u00e7e\u015fitli tiplerde mevcuttur:<\/p>\n<ul>\n<li><strong>AC s\u0131n\u0131f\u0131:<\/strong> Yava\u015f\u00e7a artan sin\u00fczoidal AC art\u0131k ak\u0131mlar i\u00e7in a\u00e7ma sa\u011flar, temel kurulumlar i\u00e7in uygundur<\/li>\n<li><strong>Bir s\u0131n\u0131f:<\/strong> Aniden uygulanan veya yava\u015f\u00e7a artan sin\u00fczoidal AC art\u0131k ak\u0131mlar\u0131 ve darbeli DC art\u0131k ak\u0131mlar\u0131 i\u00e7in a\u00e7ma sa\u011flar<\/li>\n<li><strong>ASi Tipi:<\/strong> \u0130stenmeyen a\u00e7malara kar\u015f\u0131 y\u00fcksek ba\u011f\u0131\u015f\u0131kl\u0131k i\u00e7in A tipi \u00f6zellikleri S\u00fcper ba\u011f\u0131\u015f\u0131k (Si) teknolojisi ile birle\u015ftirir<\/li>\n<li><strong>F tipi:<\/strong> T\u00fcm ASi \u00f6zelliklerinin yan\u0131 s\u0131ra 1 kHz'e kadar y\u00fcksek frekansl\u0131 ak\u0131mlar\u0131n alg\u0131lanmas\u0131n\u0131 i\u00e7erir<\/li>\n<li><strong>B tipi:<\/strong> T\u00fcm F tipi \u00f6zelliklerin yan\u0131 s\u0131ra d\u00fczg\u00fcn DC ak\u0131mlar\u0131n\u0131n alg\u0131lanmas\u0131n\u0131 i\u00e7erir<\/li>\n<li><strong>B+ tipi:<\/strong> T\u00fcm B-tipi \u00f6zelliklerin yan\u0131 s\u0131ra 20 kHz'e kadar y\u00fcksek frekansl\u0131 ak\u0131mlar\u0131n alg\u0131lanmas\u0131n\u0131 sa\u011flar<\/li>\n<\/ul>\n<p>Not: ASi tipi hem G\/KV i\u015flevini hem de Si i\u015flevini i\u00e7erir ve geli\u015fmi\u015f ba\u011f\u0131\u015f\u0131kl\u0131k ile kapsaml\u0131 koruma sa\u011flar.<\/p>\n<h2>5. VML01 RCCB i\u00e7in Kurulum ve Entegrasyon Y\u00f6nergeleri<\/h2>\n<h3>5.1 Boyutlar ve Montaj<\/h3>\n<p>VML01 RCCB, h\u0131zl\u0131 bir klips cihaz\u0131 kullan\u0131larak standart 35 mm DIN raylar\u0131na (EN 60715) kolay kurulum i\u00e7in tasarlanm\u0131\u015ft\u0131r. Cihaz, kablolama ve bak\u0131m i\u00e7in eri\u015filebilirli\u011fi korurken da\u011f\u0131t\u0131m panolar\u0131ndaki alan\u0131 optimize eden kompakt boyutlara sahiptir.<\/p>\n<h3>5.2 Da\u011f\u0131t\u0131m Sistemlerinde Se\u00e7ici Koordinasyon<\/h3>\n<p>VML01 RCCB, se\u00e7ici koordinasyon yoluyla sofistike koruma \u015femalar\u0131n\u0131 destekler. \u00c7ok seviyeli da\u011f\u0131t\u0131m sistemlerinde, Se\u00e7ici (S) tipi RCCB'ler yukar\u0131 ak\u0131\u015f konumlar\u0131na monte edilebilirken, Anl\u0131k veya K\u0131sa zaman gecikmeli tipler a\u015fa\u011f\u0131 ak\u0131\u015f konumuna yerle\u015ftirilebilir. Bu d\u00fczenleme, ar\u0131zalar\u0131n meydana geldikleri noktaya en yak\u0131n noktada izole edilmesini ve etkilenmeyen devrelerin g\u00fcc\u00fcn\u00fcn korunmas\u0131n\u0131 sa\u011flar.<\/p>\n<h3>5.3 Ba\u011flant\u0131 ve Terminal \u00d6zellikleri<\/h3>\n<p>Cihaz, \u00e7e\u015fitli kurulum konfig\u00fcrasyonlar\u0131n\u0131 bar\u0131nd\u0131ran hem \u00fcstten hem de alttan \u00e7ift ba\u011flant\u0131 se\u00e7eneklerine sahiptir. Terminal \u00f6zellikleri a\u015fa\u011f\u0131dakilere izin verir:<\/p>\n<ul>\n<li>35 mm\u00b2'ye (18-2 AWG) kadar kablo ba\u011flant\u0131lar\u0131<\/li>\n<li>Pim tipi bara ba\u011flant\u0131lar\u0131 16 mm\u00b2'ye (18-5 AWG) kadar<\/li>\n<\/ul>\n<p>T\u00fcm terminaller IP20 s\u0131n\u0131f\u0131ndad\u0131r, kurulum ve bak\u0131m i\u00e7in eri\u015filebilirli\u011fi korurken parmak korumas\u0131 sa\u011flar.<\/p>\n<h2>6. VML01 RCCB'nin Performans ve G\u00fcvenilirlik \u00d6zellikleri<\/h2>\n<h3>6.1 \u00c7evresel Dayan\u0131kl\u0131l\u0131k<\/h3>\n<p>VML01 RCCB, geni\u015f bir s\u0131cakl\u0131k aral\u0131\u011f\u0131nda g\u00fcvenilir performans g\u00f6sterecek \u015fekilde tasarlanm\u0131\u015ft\u0131r:<\/p>\n<ul>\n<li><strong>\u00c7al\u0131\u015fma s\u0131cakl\u0131\u011f\u0131:<\/strong> -25\u00b0C ila 55\u00b0C (g\u00fcnl\u00fck ortalama \u226435\u00b0C ile)<\/li>\n<li><strong>Depolama s\u0131cakl\u0131\u011f\u0131:<\/strong> -40\u00b0C ila 70\u00b0C<\/li>\n<\/ul>\n<p>Bu termal esneklik, so\u011fuk end\u00fcstriyel ortamlardan s\u0131cak hizmet odalar\u0131na kadar \u00e7e\u015fitli kurulum ortamlar\u0131nda tutarl\u0131 \u00e7al\u0131\u015fma sa\u011flar.<\/p>\n<h3>6.2 Operasyonel \u00d6m\u00fcr<\/h3>\n<p>VML01 RCCB, \u22652000 operasyonluk hem elektriksel hem de mekanik \u00f6m\u00fcr de\u011ferleriyle uzun vadeli g\u00fcvenilirlik sunar ve bak\u0131m gereksinimlerini azalt\u0131r. Bu uzat\u0131lm\u0131\u015f \u00e7al\u0131\u015fma \u00f6mr\u00fc, daha d\u00fc\u015f\u00fck de\u011fi\u015ftirme maliyetleri ve geli\u015fmi\u015f sistem g\u00fcvenilirli\u011fi anlam\u0131na gelir.<\/p>\n<h3>6.3 Ar\u0131za G\u00f6stergesi<\/h3>\n<p>VML01 RCCB, art\u0131k ak\u0131m hatas\u0131 nedeniyle bir hata olu\u015ftu\u011funda g\u00f6rsel onay sa\u011flayan dahili bir hata ak\u0131m\u0131 g\u00f6stergesi i\u00e7erir. Bu \u00f6zellik sorun gidermeyi h\u0131zland\u0131r\u0131r ve ar\u0131za \u00e7\u00f6z\u00fcm\u00fc s\u0131ras\u0131nda ar\u0131za s\u00fcresini en aza indirir.<\/p>\n<h2>7. Uyum ve Belgelendirme<\/h2>\n<p>VML01 RCCB, IEC\/EN 61008-1 standard\u0131na uygun olarak \u00fcretilmi\u015ftir ve entegre a\u015f\u0131r\u0131 ak\u0131m korumas\u0131 olmayan art\u0131k ak\u0131mla \u00e7al\u0131\u015fan devre kesiciler i\u00e7in uluslararas\u0131 kabul g\u00f6rm\u00fc\u015f gereksinimleri kar\u015f\u0131lamas\u0131n\u0131 sa\u011flar. Bu uyumluluk, cihaz\u0131n k\u00fcresel g\u00fcvenlik standartlar\u0131na uygun olarak g\u00fcvenilir koruma sa\u011flamas\u0131n\u0131 garanti eder.<\/p>\n<h2>8. Elektrik Tesisat\u0131n\u0131z i\u00e7in Neden VML01 RCCB'yi Se\u00e7melisiniz?<\/h2>\n<h3>8.1 Kapsaml\u0131 Koruma<\/h3>\n<p>VML01 RCCB, dolayl\u0131 temastan kaynaklanan elektrik \u00e7arpmas\u0131na, do\u011frudan temasa ve yal\u0131t\u0131m hatalar\u0131ndan kaynaklanan yang\u0131n tehlikelerine kar\u015f\u0131 \u00e7ok katmanl\u0131 koruma sa\u011flar. \u00c7e\u015fitli hassasiyet se\u00e7enekleri ve dalga formu alg\u0131lama \u00f6zellikleri, her t\u00fcrl\u00fc uygulama i\u00e7in uygun koruma sa\u011flar.<\/p>\n<h3>8.2 \u00c7ok Y\u00f6nl\u00fcl\u00fck ve Uyarlanabilirlik<\/h3>\n<p>\u00c7oklu kutup konfig\u00fcrasyonlar\u0131 (2P, 4P), ak\u0131m de\u011ferleri (16A ila 100A) ve hassasiyet e\u015fikleri (10mA ila 300mA) ile VML01 RCCB, konut, ticari ve end\u00fcstriyel ortamlardaki \u00f6zel kurulum gereksinimlerini kar\u015f\u0131lamak i\u00e7in tam olarak uyarlanabilir.<\/p>\n<h3>8.3 G\u00fcvenilirlik ve Dayan\u0131kl\u0131l\u0131k<\/h3>\n<p>Uzun \u00e7al\u0131\u015fma \u00f6mr\u00fc ve zorlu \u00e7evre ko\u015fullar\u0131nda tutarl\u0131 performans i\u00e7in tasarlanan VML01 RCCB, bak\u0131m gereksinimlerini en aza indiren ve sistem g\u00fcvenilirli\u011fini art\u0131ran g\u00fcvenilir koruma sa\u011flar.<\/p>\n<h3>8.4 Kurulum Esnekli\u011fi<\/h3>\n<p>Cihaz\u0131n DIN ray\u0131 montaj sistemi, \u00e7ok y\u00f6nl\u00fc terminal ba\u011flant\u0131lar\u0131 ve kompakt boyutlar\u0131, \u00e7e\u015fitli da\u011f\u0131t\u0131m panosu konfig\u00fcrasyonlar\u0131nda kolay kurulumu kolayla\u015ft\u0131rarak hem yeni kurulumlar\u0131 hem de sistem y\u00fckseltmelerini basitle\u015ftirir.<\/p>\n<h2>9.VML01 2P Ka\u00e7ak Ak\u0131mla \u00c7al\u0131\u015fan Devre Kesici (RCCB) Boyut<\/h2>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-13918\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VML01-2P-Residual-Current-Operated-Circuit-Breaker-RCCB-Dimension.webp\" alt=\"VML01 2P Residual Current Operated Circuit Breaker (RCCB) Dimension\" width=\"800\" height=\"260\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VML01-2P-Residual-Current-Operated-Circuit-Breaker-RCCB-Dimension.webp 800w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VML01-2P-Residual-Current-Operated-Circuit-Breaker-RCCB-Dimension-300x98.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VML01-2P-Residual-Current-Operated-Circuit-Breaker-RCCB-Dimension-768x250.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VML01-2P-Residual-Current-Operated-Circuit-Breaker-RCCB-Dimension-18x6.webp 18w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VML01-2P-Residual-Current-Operated-Circuit-Breaker-RCCB-Dimension-600x195.webp 600w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<h2>10. Sonu\u00e7<\/h2>\n<p>VML01 Ka\u00e7ak Ak\u0131m Devre Kesici, modern elektrik g\u00fcvenlik sistemlerinde \u00f6nemli bir bile\u015feni temsil eder. Ak\u0131m ka\u00e7a\u011f\u0131n\u0131 tespit ederek ve etkilenen devrelerin ba\u011flant\u0131s\u0131n\u0131 h\u0131zla keserek, elektrik \u00e7arpmas\u0131 ve yang\u0131n tehlikelerine kar\u015f\u0131 kritik koruma sa\u011flar.<\/p>\n<p>\u00c7e\u015fitli yap\u0131land\u0131rma se\u00e7enekleri, geli\u015fmi\u015f koruma \u00f6zellikleri ve sa\u011flam yap\u0131s\u0131 ile VML01 RCCB, konut, ticari ve end\u00fcstriyel uygulamalardaki elektrik tesisatlar\u0131 i\u00e7in kapsaml\u0131 g\u00fcvenlik sa\u011flar. \u0130ster hassas ekipman\u0131 koruyor, ister banyo devrelerini muhafaza ediyor veya end\u00fcstriyel ortamlarda yang\u0131n tehlikelerini \u00f6nl\u00fcyor olsun, VML01 RCCB hem insan g\u00fcvenli\u011fini hem de sistem b\u00fct\u00fcnl\u00fc\u011f\u00fcn\u00fc koruyan g\u00fcvenilir, standartlara uygun koruma sunar.<\/p>\n<p>VML01 RCCB ile ilgili ek bilgi veya teknik destek i\u00e7in, l\u00fctfen \u00f6zel uygulama gereksinimleriniz i\u00e7in en uygun yap\u0131land\u0131rmay\u0131 se\u00e7menize yard\u0131mc\u0131 olabilecek uzman ekibimizle ileti\u015fime ge\u00e7in.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<div class=\"markdown\">\n<p>VIOX VML01 2P Ka\u00e7ak Ak\u0131m Devre Kesici (RCCB), konut, ticari ve end\u00fcstriyel uygulamalar i\u00e7in \u00fcst\u00fcn elektrik g\u00fcvenli\u011fi sunar. Bu manyetik tip RCCB (IEC\/EN 61008-1), toprak ka\u00e7a\u011f\u0131n\u0131 tespit ederek elektrik \u00e7arpmas\u0131 ve yang\u0131n tehlikelerine kar\u015f\u0131 koruma sa\u011flar. AC ve A tiplerinde, 10mA ila 300mA aras\u0131 hassasiyetlerde mevcuttur.<\/p>\n<\/div>","protected":false},"featured_media":13917,"comment_status":"closed","ping_status":"closed","template":"","meta":{"inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[],"product_cat":[131],"product_tag":[],"class_list":{"0":"post-13916","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-rccb","7":"desktop-align-left","8":"tablet-align-left","9":"mobile-align-left","11":"first","12":"instock","13":"shipping-taxable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product\/13916","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/comments?post=13916"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/media\/13917"}],"wp:attachment":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/media?parent=13916"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product_brand?post=13916"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product_cat?post=13916"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product_tag?post=13916"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}