{"id":12137,"date":"2024-12-27T14:42:44","date_gmt":"2024-12-27T06:42:44","guid":{"rendered":"https:\/\/viox.com\/?post_type=product&#038;p=12137"},"modified":"2024-12-27T14:43:21","modified_gmt":"2024-12-27T06:43:21","slug":"nylon-breather-vent-plug-v1","status":"publish","type":"product","link":"https:\/\/test.viox.com\/tr\/urun\/nylon-breather-vent-plug-v1\/","title":{"rendered":"Naylon Havaland\u0131rma Tapas\u0131"},"content":{"rendered":"<div class=\"product-intro\">\n<h2>Naylon Havaland\u0131rma Tapas\u0131<\/h2>\n<h2>Genel Bak\u0131\u015f<\/h2>\n<p>VIOX Naylon Havaland\u0131rma Tapas\u0131, d\u0131\u015f ayd\u0131nlatma ve muhafazalarda bas\u0131n\u00e7 dengesini korumak ve yo\u011fu\u015fmay\u0131 \u00f6nlemek i\u00e7in tasarlanm\u0131\u015ft\u0131r. \u00c7e\u015fitli end\u00fcstriyel uygulamalarda dayan\u0131kl\u0131l\u0131k ve g\u00fcvenilirlik sa\u011flamak i\u00e7in y\u00fcksek kaliteli malzemelerle sa\u011flam bir tasar\u0131ma sahiptir. Bu havaland\u0131rma tapas\u0131, nem ve toz giri\u015fini \u00f6nlerken havan\u0131n ge\u00e7mesine izin verir, bu da onu tehlikeli alanlar ve patlamaya dayan\u0131kl\u0131 elektrikli ekipman ba\u011flant\u0131lar\u0131 i\u00e7in ideal hale getirir.<\/p>\n<h2>Teknik Parametreler<\/h2>\n<table>\n<tbody>\n<tr>\n<th>\u00d6\u011fe<\/th>\n<th>Detaylar<\/th>\n<\/tr>\n<tr>\n<td>Konu<\/td>\n<td>Metrik, PG, G (PF) ve NPT<\/td>\n<\/tr>\n<tr>\n<td>Koruma Derecesi<\/td>\n<td>IP67-IP68 (O-ring ile) (2 metre \/ 60 dakika)<\/td>\n<\/tr>\n<tr>\n<td>\u00c7al\u0131\u015fma S\u0131cakl\u0131\u011f\u0131<\/td>\n<td>-40 \u2103 ila 100 \u2103, 120 \u2103'ye kadar anl\u0131k \u0131s\u0131 direnci. Dinamik olarak -20 \u2103 ila 80 \u2103, 100 \u2103'ye kadar anl\u0131k \u0131s\u0131 direnci.<\/td>\n<\/tr>\n<tr>\n<td>Malzemeler<\/td>\n<td>Nefes alabilen membran i\u00e7in ePTFE, ana g\u00f6vde ve somun par\u00e7alar\u0131 i\u00e7in nikel kaplamal\u0131 pirin\u00e7, O-ring i\u00e7in y\u00fcksek s\u0131cakl\u0131\u011fa dayan\u0131kl\u0131 silikon<\/td>\n<\/tr>\n<tr>\n<td>Tipik Hava Ak\u0131\u015f\u0131<\/td>\n<td>2000ml\/dak (dp=70mbar)<\/td>\n<\/tr>\n<tr>\n<td>Su Giri\u015f Bas\u0131nc\u0131<\/td>\n<td>5 psi\/30 sn = 0,34 bar\/30 sn<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>\u00d6zellikler<\/h2>\n<ul>\n<li>Nem ve toz giri\u015fini \u00f6nlerken hava ge\u00e7i\u015fine izin verir.<\/li>\n<li>Bas\u0131n\u00e7 dengesini korur ve muhafazalarda yo\u011fu\u015fmay\u0131 \u00f6nler.<\/li>\n<li>Su derinli\u011fi ve hava ge\u00e7irgenli\u011fine ba\u011fl\u0131 olarak \u00f6zelle\u015ftirilebilir su ge\u00e7irmezlik seviyesi.<\/li>\n<li>Tehlikeli alanlar, patlamaya dayan\u0131kl\u0131 elektrikli ekipmanlar, kimyasallar, petrol ve \u00e7e\u015fitli elektrik, hafif sanayi ve makine sekt\u00f6rleri i\u00e7in idealdir.<\/li>\n<\/ul>\n<h2>\u00dcr\u00fcn A\u00e7\u0131klamas\u0131<\/h2>\n<p>VIOX Naylon Havaland\u0131rma Tapas\u0131, kompakt bir yap\u0131 ve m\u00fckemmel nefes alabilirlik sunan, polimer malzemelerden yap\u0131lm\u0131\u015f yeni bir nefes alabilir malzeme t\u00fcr\u00fcd\u00fcr. T\u0131bbi, end\u00fcstriyel, in\u015faat ve di\u011fer alanlarda \u00e7e\u015fitli nefes alabilen ekipman ve malzemelerde yayg\u0131n olarak kullan\u0131lmaktad\u0131r.<\/p>\n<h2>\u00dcr\u00fcn \u00d6zellikleri<\/h2>\n<ul>\n<li><strong>Y\u00fcksek Nefes Alabilirlik:<\/strong> Ekipman\u0131n i\u00e7 havaland\u0131rmas\u0131n\u0131n iyi olmas\u0131n\u0131 sa\u011flayarak i\u015fleme verimlili\u011fini ve performans\u0131n\u0131 art\u0131r\u0131r.<\/li>\n<li><strong>G\u00fc\u00e7l\u00fc A\u015f\u0131nma Direnci:<\/strong> Kirleticilere kar\u015f\u0131 diren\u00e7li, zaman i\u00e7inde performans\u0131n\u0131 koruyan p\u00fcr\u00fczs\u00fcz y\u00fczey.<\/li>\n<li><strong>Y\u00fcksek S\u0131cakl\u0131k Dayan\u0131m\u0131:<\/strong> Y\u00fcksek s\u0131cakl\u0131klara deforme olmadan, erimeden veya \u00e7atlamadan dayan\u0131r.<\/li>\n<li><strong>Su ve Toz Ge\u00e7irmez:<\/strong> Dahili ekipman\u0131 harici kirlenmeye kar\u015f\u0131 korur.<\/li>\n<li><strong>Y\u00fcksek Mukavemet:<\/strong> Uzun s\u00fcreli istikrarl\u0131 \u00e7al\u0131\u015fma i\u00e7in y\u00fcksek mukavemet ve yorulma direnci sunar.<\/li>\n<\/ul>\n<h2>\u00dcr\u00fcn Avantajlar\u0131<\/h2>\n<ul>\n<li><strong>Ekonomik ve Uygun Fiyatl\u0131:<\/strong> D\u00fc\u015f\u00fck kullan\u0131m maliyetleri ile uygun maliyetli.<\/li>\n<li><strong>Kullan\u0131\u015fl\u0131 Bak\u0131m:<\/strong> Uzun hizmet \u00f6mr\u00fc ile basit ve rahat bak\u0131m.<\/li>\n<li><strong>Geni\u015f Uygulanabilirlik:<\/strong> \u00c7e\u015fitli alanlarda gaz ve s\u0131v\u0131 ar\u0131tma ve filtreleme i\u00e7in uygundur.<\/li>\n<li><strong>Hafif Tasar\u0131m:<\/strong> Ekipman a\u011f\u0131rl\u0131\u011f\u0131n\u0131 azaltarak \u00e7al\u0131\u015fma verimlili\u011fini ve performans\u0131n\u0131 art\u0131r\u0131r.<\/li>\n<\/ul>\n<h2>Uygulama Alanlar\u0131<\/h2>\n<ul>\n<li><strong>T\u0131p alan\u0131nda:<\/strong> Vantilat\u00f6rler ve hemodiyaliz makineleri gibi t\u0131bbi ekipmanlarda kullan\u0131l\u0131r.<\/li>\n<li><strong>End\u00fcstriyel Alan:<\/strong> Gaz filtrasyonu, s\u0131v\u0131 ar\u0131tma ve \u00e7evre koruma ekipmanlar\u0131 i\u00e7in uygundur.<\/li>\n<li><strong>\u0130n\u015faat Alan\u0131:<\/strong> B\u00f6lmeler ve duvar panelleri gibi yap\u0131 malzemelerinde kullan\u0131l\u0131r.<\/li>\n<\/ul>\n<h2>Teknik Veri Sayfas\u0131<\/h2>\n<table>\n<tbody>\n<tr>\n<th>Konu<\/th>\n<th>Di\u015f O.D (mm)<\/th>\n<th>Di\u015f Uzunlu\u011fu (mm)<\/th>\n<th>G\u00f6vde Malzemesi<\/th>\n<th>Hava Ge\u00e7irgenli\u011fi<\/th>\n<th>Koruma Seviyesi<\/th>\n<th>Oleofobik S\u0131n\u0131f<\/th>\n<\/tr>\n<tr>\n<td>M24*1.5<\/td>\n<td>24<\/td>\n<td>10<\/td>\n<td>PA66\/PC<\/td>\n<td>7kpa'da &gt;7000ml\/dk<\/td>\n<td>IP68<\/td>\n<td>8<\/td>\n<\/tr>\n<tr>\n<td>M16*1.5<\/td>\n<td>16<\/td>\n<td>9<\/td>\n<td>PA66\/PC<\/td>\n<td>7kpa'da &gt;4600ml\/dk<\/td>\n<td>IP68<\/td>\n<td>8<\/td>\n<\/tr>\n<tr>\n<td>M12*1.5<\/td>\n<td>12<\/td>\n<td>9<\/td>\n<td>PA66\/PC<\/td>\n<td>7kpa'da &gt;2200ml\/dak<\/td>\n<td>IP68<\/td>\n<td>8<\/td>\n<\/tr>\n<tr>\n<td>M10*1.5<\/td>\n<td>10<\/td>\n<td>9<\/td>\n<td>PA66\/PC<\/td>\n<td>7kpa'da &gt;2200ml\/dak<\/td>\n<td>IP68<\/td>\n<td>8<\/td>\n<\/tr>\n<tr>\n<td>M8*1.25<\/td>\n<td>8<\/td>\n<td>9<\/td>\n<td>PA66\/PC<\/td>\n<td>7kpa'da &gt;1200ml\/dk<\/td>\n<td>IP68<\/td>\n<td>8<\/td>\n<\/tr>\n<tr>\n<td>M6*0.75<\/td>\n<td>6<\/td>\n<td>6<\/td>\n<td>PA66\/PC<\/td>\n<td>7kpa'da &gt;600ml\/dk<\/td>\n<td>IP68<\/td>\n<td>8<\/td>\n<\/tr>\n<tr>\n<td>M5*0.8<\/td>\n<td>5<\/td>\n<td>6<\/td>\n<td>PA66\/PC<\/td>\n<td>7kpa'da &gt;600ml\/dk<\/td>\n<td>IP68<\/td>\n<td>8<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Di\u015f:Metrik, PG, G (PF), ve NPT<br \/>\nKoruma Derecesi: IP67-IP68 (O-ring ile) (2 metre \/ 60 dakika)<br \/>\n\u00c7al\u0131\u015fma S\u0131cakl\u0131\u011f\u0131: -40 \u2103 ila 100 \u2103, 120 \u2103'ye kadar anl\u0131k \u0131s\u0131 direnci. Dinamik olarak -20 \u2103 ila 80 \u2103, 100 \u2103'ye kadar anl\u0131k \u0131s\u0131 direnci.<br \/>\nMalzemeler: nefes alabilen membran i\u00e7in ePTFE, ana g\u00f6vde ve somun par\u00e7alar\u0131 i\u00e7in nikel kaplamal\u0131 pirin\u00e7, O-ring i\u00e7in y\u00fcksek s\u0131cakl\u0131\u011fa dayan\u0131kl\u0131 silikon<br \/>\nTipik Hava Ak\u0131\u015f\u0131: 2000ml\/dak (dp=70mbar)<br \/>\nSu Giri\u015f Bas\u0131nc\u0131: 5 psi\/30 sn = 0,34 bar\/30 sn<\/p>","protected":false},"featured_media":12138,"comment_status":"closed","ping_status":"closed","template":"","meta":{"inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[],"product_cat":[190],"product_tag":[],"class_list":{"0":"post-12137","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-breather-vent-plug","7":"desktop-align-left","8":"tablet-align-left","9":"mobile-align-left","11":"first","12":"instock","13":"shipping-taxable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product\/12137","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/comments?post=12137"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/media\/12138"}],"wp:attachment":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/media?parent=12137"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product_brand?post=12137"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product_cat?post=12137"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/product_tag?post=12137"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}