{"id":7120,"date":"2024-09-24T16:25:33","date_gmt":"2024-09-24T08:25:33","guid":{"rendered":"https:\/\/viox.com\/?p=7120"},"modified":"2026-03-28T16:50:34","modified_gmt":"2026-03-28T08:50:34","slug":"full-guide-to-molded-case-circuit-breakers-mccbs","status":"publish","type":"post","link":"https:\/\/test.viox.com\/tr\/full-guide-to-molded-case-circuit-breakers-mccbs\/","title":{"rendered":"Kompakt \u015ealter (MCCB) Nedir? \u00c7al\u0131\u015fma Prensibi, Bile\u015fenleri, De\u011ferleri ve Uygulamalar\u0131na \u0130li\u015fkin Eksiksiz K\u0131lavuz"},"content":{"rendered":"<div class=\"product-intro\">\n<h2>Do\u011frudan Cevap<\/h2>\n<figure style=\"text-align: center;\"><img decoding=\"async\" src=\"https:\/\/img.viox.com\/Molded-case-circuit-breaker-installed-in-a-low-voltage-industrial-distribution-panel.webp\" alt=\"Molded case circuit breaker installed in a low voltage industrial distribution panel\" \/><figcaption><em>A\u011f\u0131r hizmet tipi kal\u0131pl\u0131 kasa devre kesici (MCCB), da\u011f\u0131t\u0131m ekipman\u0131n\u0131 korumaya haz\u0131r, al\u00e7ak gerilim end\u00fcstriyel da\u011f\u0131t\u0131m paneli i\u00e7inde g\u00fcvenli bir \u015fekilde kurulmu\u015ftur.<\/em><\/figcaption><\/figure>\n<p>A <strong>kal\u0131pl\u0131 k\u0131l\u0131fl\u0131 devre kesici (MCCB)<\/strong> a\u015f\u0131r\u0131 y\u00fck ve k\u0131sa devrelere kar\u015f\u0131 besleyicileri, daha b\u00fcy\u00fck bran\u015fman devrelerini, makine beslemelerini ve da\u011f\u0131t\u0131m ekipman\u0131n\u0131 korumak i\u00e7in kullan\u0131lan al\u00e7ak gerilim devre kesicidir. Daha k\u00fc\u00e7\u00fck bir <a href=\"https:\/\/test.viox.com\/tr\/mcb\/\">MCB&#039;N\u0130N<\/a>, ile kar\u015f\u0131la\u015ft\u0131r\u0131ld\u0131\u011f\u0131nda, bir MCCB tipik olarak ticari ve end\u00fcstriyel g\u00fc\u00e7 sistemleri i\u00e7in daha y\u00fcksek bir ak\u0131m aral\u0131\u011f\u0131, daha y\u00fcksek kesme kapasitesi ve daha esnek a\u00e7ma \u00fcnitesi se\u00e7enekleri sunar.<\/p>\n<p>Pratik olarak, bir MCCB al\u00e7ak gerilim koruma hiyerar\u015fisinin ortas\u0131nda yer al\u0131r:<\/p>\n<ul>\n<li><strong><a href=\"https:\/\/test.viox.com\/tr\/mcb\/\">MCB&#039;N\u0130N<\/a><\/strong> daha k\u00fc\u00e7\u00fck nihai devreler i\u00e7in<\/li>\n<li><a href=\"https:\/\/test.viox.com\/tr\/mccb\/\"><strong>MCCB'N\u0130N<\/strong><\/a> daha b\u00fcy\u00fck besleyiciler ve daha y\u00fcksek g\u00f6revli bran\u015fman korumas\u0131 i\u00e7in<\/li>\n<li><strong><a href=\"https:\/\/test.viox.com\/tr\/acb\/\">ACB<\/a><\/strong> en y\u00fcksek ak\u0131ml\u0131 al\u00e7ak gerilim \u015falt cihaz\u0131 rolleri i\u00e7in<\/li>\n<\/ul>\n<p>Sisteminizin minyat\u00fcr bir kesiciyi a\u015ft\u0131\u011f\u0131na karar vermeye \u00e7al\u0131\u015f\u0131yorsan\u0131z, bu pratik e\u015fiktir: <strong>bir MCCB, devrenin minyat\u00fcr bir kesicinin genellikle sa\u011flayabilece\u011finden daha fazla kapasiteye ve daha fazla koruma esnekli\u011fine ihtiya\u00e7 duydu\u011fu durumlarda kullan\u0131lan daha a\u011f\u0131r hizmet tipi al\u00e7ak gerilim kesicidir.<\/strong><\/p>\n<p>Yaln\u0131zca k\u0131saltma a\u00e7\u0131klamas\u0131n\u0131 istiyorsan\u0131z, bkz. <a href=\"https:\/\/test.viox.com\/tr\/mccb-full-form-molded-case-circuit-breaker\/\">MCCB Tam Formu: Kal\u0131pl\u0131 Kasa Devre Kesici<\/a>.<\/p>\n<h2>\u00d6nemli \u00c7\u0131kar\u0131mlar<\/h2>\n<ul>\n<li>Bir MCCB bir <strong>kal\u0131planm\u0131\u015f kasa devre kesici<\/strong> al\u00e7ak gerilim besleyici ve daha y\u00fcksek g\u00f6revli devre korumas\u0131 i\u00e7in kullan\u0131l\u0131r.<\/li>\n<li>MCCB'ler genellikle ak\u0131m, ar\u0131za seviyesi veya a\u00e7ma ayar\u0131 gereksinimlerinin standart <a href=\"https:\/\/test.viox.com\/tr\/mcb\/\">MCB'ler<\/a>.<\/li>\n<li>pratik aral\u0131\u011f\u0131n\u0131 a\u015ft\u0131\u011f\u0131 durumlarda kullan\u0131l\u0131r.<\/li>\n<li>Anla\u015f\u0131lmas\u0131 gereken en \u00f6nemli \u015feyler \u015funlard\u0131r: bir MCCB'nin i\u00e7inde ne var, nas\u0131l a\u00e7ma yap\u0131yor ve hangi de\u011ferler \u00f6nemli.<\/li>\n<li>Temel de\u011ferler sadece ak\u0131m ve gerilim de\u011fildir. Bunlar ayr\u0131ca kesme kapasitesi, a\u00e7ma \u00fcnitesi tipi ve aksesuar gereksinimlerini de i\u00e7erir.<\/li>\n<\/ul>\n<h2>MCCB Nedir?<\/h2>\n<p>Bir MCCB k\u0131lavuzu \u00f6nce temelleri a\u00e7\u0131klamal\u0131d\u0131r. Ayr\u0131nt\u0131l\u0131 se\u00e7im, kar\u015f\u0131la\u015ft\u0131rma ve a\u00e7ma \u00fcnitesi ayar\u0131 daha sonra daha \u00f6zel sayfalara ayr\u0131labilir.<\/p>\n<p>Bir MCCB, kal\u0131planm\u0131\u015f yal\u0131t\u0131m muhafazas\u0131 i\u00e7ine al\u0131nm\u0131\u015f bir a\u015f\u0131r\u0131 ak\u0131m koruma cihaz\u0131d\u0131r. Devrenin tipik olarak minyat\u00fcr bir bran\u015fman kesicinin sunabilece\u011finden daha sa\u011flam bir koruma talep etti\u011fi al\u00e7ak gerilim sistemleri i\u00e7in tasarlanm\u0131\u015ft\u0131r. <code>\u0130fade<\/code> kal\u0131planm\u0131\u015f kasa.<\/p>\n<p>ak\u0131m ta\u015f\u0131yan kontaklar\u0131, \u00e7al\u0131\u015ft\u0131rma mekanizmas\u0131n\u0131, ark kesme yap\u0131s\u0131n\u0131 ve a\u00e7ma \u00fcnitesini i\u00e7eren yal\u0131t\u0131m muhafazas\u0131na at\u0131fta bulunur. Kesici, bir ACB gibi a\u00e7\u0131k \u00e7er\u00e7eveli de\u011fildir ve k\u00fc\u00e7\u00fck bir DIN rayl\u0131 minyat\u00fcr kesici kadar kompakt veya g\u00f6rev a\u00e7\u0131s\u0131ndan s\u0131n\u0131rl\u0131 de\u011fildir.<\/p>\n<ul>\n<li>\u00c7o\u011fu ger\u00e7ek kurulumda, MCCB'ler \u015funlar i\u00e7in kullan\u0131l\u0131r:<\/li>\n<li>da\u011f\u0131t\u0131m panolar\u0131ndan \u00e7\u0131kan besleyiciler<\/li>\n<li>daha b\u00fcy\u00fck motor ve makine devreleri<\/li>\n<li>alt ana da\u011f\u0131t\u0131m<\/li>\n<li>jenerat\u00f6r ve transferle ilgili besleyici korumas\u0131<\/li>\n<\/ul>\n<p>tipik MCB g\u00f6revlerinin \u00fczerindeki panel panosu ve \u015falt cihaz\u0131 bran\u015fman korumas\u0131 <a href=\"https:\/\/test.viox.com\/tr\/mccb\/\">E\u011fitici genel bak\u0131\u015f yerine \u00fcr\u00fcn d\u00fczeyinde bir g\u00f6r\u00fcn\u00fcm istiyorsan\u0131z, bkz.<\/a>.<\/p>\n<h2>VIOX MCCB sayfas\u0131<\/h2>\n<figure style=\"text-align: center;\"><img decoding=\"async\" src=\"https:\/\/img.viox.com\/Technical-diagram-showing-how-a-molded-case-circuit-breaker-detects-faults-and-interrupts-current.webp\" alt=\"Technical diagram showing how a molded case circuit breaker detects faults and interrupts current\" \/><figcaption><em>Bir MCCB Nas\u0131l \u00c7al\u0131\u015f\u0131r.<\/em><\/figcaption><\/figure>\n<p>A\u015f\u0131r\u0131 y\u00fck ve k\u0131sa devre ko\u015fullar\u0131nda MCCB ar\u0131za tespiti ve ak\u0131m kesme s\u00fcrecini g\u00f6steren ad\u0131m ad\u0131m teknik diyagram.<\/p>\n<ol>\n<li>Y\u00fcksek bir seviyede, bir MCCB iki i\u015f yapar:.<\/li>\n<li>Normal y\u00fck ak\u0131m\u0131n\u0131 derecesi dahilinde s\u00fcrekli olarak ta\u015f\u0131r.<\/li>\n<\/ol>\n<p>Bir ar\u0131za durumu a\u00e7ma \u00f6zelliklerini a\u015ft\u0131\u011f\u0131nda devreyi otomatik olarak a\u00e7ar.<\/p>\n<ul>\n<li><strong>Kesici, ar\u0131zalar\u0131 \u015fu \u015fekilde olabilen a\u00e7ma sistemi arac\u0131l\u0131\u011f\u0131yla alg\u0131lar:<\/strong><\/li>\n<li><strong>termal-manyetik<\/strong><\/li>\n<\/ul>\n<p>elektronik<\/p>\n<ul>\n<li>Termal-manyetik bir MCCB'de:<\/li>\n<li>termal eleman s\u00fcrekli a\u015f\u0131r\u0131 y\u00fck ko\u015fullar\u0131na yan\u0131t verir<\/li>\n<\/ul>\n<p>manyetik eleman daha y\u00fcksek k\u0131sa devre ak\u0131mlar\u0131na yan\u0131t verir<\/p>\n<ul>\n<li>Elektronik bir MCCB'de:<\/li>\n<li>ak\u0131m daha hassas bir \u015fekilde \u00f6l\u00e7\u00fcl\u00fcr<\/li>\n<li>a\u00e7ma mant\u0131\u011f\u0131 genellikle birden fazla koruma fonksiyonunda ayarlanabilir<\/li>\n<\/ul>\n<p>koordinasyon ve uygulama esnekli\u011fi genellikle daha y\u00fcksektir <strong>y\u00fck\u00fc<\/strong> Daha geli\u015fmi\u015f uygulamalarda, bu genellikle m\u00fchendisin art\u0131k sadece \"a\u00e7acak m\u0131?\" diye d\u00fc\u015f\u00fcnmedi\u011fi, ayn\u0131 zamanda <code>L<\/code>, <code>S<\/code>, <code>I<\/code>, a\u00e7t\u0131\u011f\u0131 anlam\u0131na gelir. Elektronik a\u00e7ma \u00fcniteleri genellikle <code>G<\/code>:<\/p>\n<ul>\n<li><code>L<\/code> ve bazen<\/li>\n<li><code>S<\/code> = uzun s\u00fcreli koruma<\/li>\n<li><code>I<\/code> = k\u0131sa s\u00fcreli koruma<\/li>\n<li><code>G<\/code> = anl\u0131k koruma<\/li>\n<\/ul>\n<p>= sa\u011fland\u0131\u011f\u0131nda toprak ar\u0131za korumas\u0131 gibi koruma fonksiyonlar\u0131 arac\u0131l\u0131\u011f\u0131yla tart\u0131\u015f\u0131l\u0131r. <strong>Bu ayarlar cihaz\u0131n<\/strong> zaman-ak\u0131m karakteristi\u011fini (TCC).<\/p>\n<p>\u015fekillendirir ve koordinasyon \u00e7al\u0131\u015fmalar\u0131n\u0131n merkezinde yer al\u0131r. Ba\u015fka bir deyi\u015fle, elektronik bir MCCB genellikle sadece daha y\u00fcksek ak\u0131m i\u00e7in de\u011fil, ayn\u0131 zamanda a\u00e7ma davran\u0131\u015f\u0131n\u0131n sistemin geri kalan\u0131na uyacak \u015fekilde ayarlanabilmesi i\u00e7in se\u00e7ilir.<\/p>\n<p>Kesme s\u0131ras\u0131 kendisi mekanik ve elektrikseldir. A\u00e7ma \u00fcnitesi kesiciye a\u00e7ma komutu verdi\u011finde, kontaklar ayr\u0131l\u0131r, bir ark olu\u015fur ve ark, ar\u0131za ak\u0131m\u0131 g\u00fcvenli bir \u015fekilde kesilene kadar ark kontrol yap\u0131s\u0131na zorlan\u0131r. <a href=\"https:\/\/test.viox.com\/tr\/electronic-vs-thermal-magnetic-mccb\/\">Elektronik ve Termal-Manyetik MCCB<\/a>.<\/p>\n<h2>Ayr\u0131nt\u0131l\u0131 teknoloji kar\u015f\u0131la\u015ft\u0131rmas\u0131 i\u00e7in bkz.<\/h2>\n<figure style=\"text-align: center;\"><img decoding=\"async\" src=\"https:\/\/img.viox.com\/Technical-infographic-showing-the-main-internal-parts-of-a-molded-case-circuit-breaker.webp\" alt=\"Technical infographic showing the main internal parts of a molded case circuit breaker\" \/><figcaption><em>Bir MCCB'nin \u0130\u00e7inde Ne Var?.<\/em><\/figcaption><\/figure>\n<p>Bir MCCB'nin i\u00e7 bile\u015fenlerinin ayr\u0131nt\u0131l\u0131 teknik d\u00f6k\u00fcm\u00fc, a\u00e7ma \u00fcnitesini, ark odas\u0131n\u0131 ve sa\u011flam kal\u0131planm\u0131\u015f kasay\u0131 sergiliyor. <code>Bu,<\/code> mccb'nin i\u00e7i.<\/p>\n<p>sorgusunu yan\u0131tlaman\u0131n en yararl\u0131 yollar\u0131ndan biridir, \u00e7\u00fcnk\u00fc bir\u00e7ok okuyucu asl\u0131nda cihaz\u0131n nas\u0131l yap\u0131ld\u0131\u011f\u0131n\u0131 ve neden minyat\u00fcr bir kesiciden daha pahal\u0131ya mal oldu\u011funu soruyor.<\/p>\n<h3>Bir MCCB'nin tipik i\u00e7 b\u00f6l\u00fcmleri \u015funlar\u0131 i\u00e7erir:<\/h3>\n<p>1. Kal\u0131planm\u0131\u015f Yal\u0131t\u0131m Kasas\u0131.<\/p>\n<h3>Muhafaza, mekanik koruma, yal\u0131t\u0131m, boyutsal kararl\u0131l\u0131k ve i\u00e7 par\u00e7alar i\u00e7in destek sa\u011flar. \u015ealt cihazlar\u0131nda ve panolarda \u0131s\u0131ya, ar\u0131za gerilimine ve uzun hizmet \u00f6mr\u00fcne dayanmal\u0131d\u0131r.<\/h3>\n<p>Bunlar normal \u00e7al\u0131\u015fma s\u0131ras\u0131nda ak\u0131m ta\u015f\u0131r ve devre kesici a\u00e7t\u0131\u011f\u0131nda ayr\u0131l\u0131r. Kontak tasar\u0131m\u0131, s\u0131cakl\u0131k art\u0131\u015f\u0131n\u0131, g\u00fcvenilirli\u011fi ve elektriksel dayan\u0131kl\u0131l\u0131\u011f\u0131 etkiler.<\/p>\n<h3>3. \u00c7al\u0131\u015fma Mekanizmas\u0131<\/h3>\n<p>\u00c7al\u0131\u015fma mekanizmas\u0131, kontaklar\u0131 a\u00e7mak veya kapatmak i\u00e7in enerji depolar ve serbest b\u0131rak\u0131r. Bu, kullan\u0131c\u0131n\u0131n kol arac\u0131l\u0131\u011f\u0131yla etkile\u015fimde bulundu\u011fu k\u0131s\u0131md\u0131r, ancak ayn\u0131 zamanda ar\u0131za ko\u015fullar\u0131nda kontaklar\u0131n kesin olarak a\u00e7\u0131lmas\u0131n\u0131 sa\u011flayan mekanik sistemdir.<\/p>\n<h3>4. A\u00e7ma \u00dcnitesi<\/h3>\n<p>A\u00e7ma \u00fcnitesi, MCCB'nin koruma beynidir. Devre kesici tipine ba\u011fl\u0131 olarak, \u015funlar olabilir:<\/p>\n<ul>\n<li>Kesici, ar\u0131zalar\u0131 \u015fu \u015fekilde olabilen a\u00e7ma sistemi arac\u0131l\u0131\u011f\u0131yla alg\u0131lar:<\/li>\n<li>ayarlanabilir ayarlara sahip elektronik<\/li>\n<\/ul>\n<p>Daha geli\u015fmi\u015f tasar\u0131mlarda, a\u00e7ma \u00fcnitesi uzun s\u00fcreli, k\u0131sa s\u00fcreli ve anl\u0131k koruma gibi i\u015flevleri ve bazen \u00fcr\u00fcn ailesine ba\u011fl\u0131 olarak ek mant\u0131\u011f\u0131 destekler.<\/p>\n<h3>5. Ark Olu\u011fu veya Ark Kesme Yap\u0131s\u0131<\/h3>\n<p>Devre kesici ar\u0131za ak\u0131m\u0131 alt\u0131nda a\u00e7\u0131ld\u0131\u011f\u0131nda, bir elektrik ark\u0131 olu\u015fur. Ark olu\u011fu, ark\u0131 uzat\u0131r, so\u011futur ve b\u00f6ler, b\u00f6ylece devre kesici ak\u0131m\u0131 g\u00fcvenli bir \u015fekilde kesebilir.<\/p>\n<h3>6. Hat ve Y\u00fck Terminalleri<\/h3>\n<p>Bunlar MCCB'yi sisteme ba\u011flar. Pratik kurulum \u00e7al\u0131\u015fmalar\u0131nda, terminal kalitesi, tork kontrol\u00fc, iletken uyumu ve bara aray\u00fcz\u00fc uzun vadeli g\u00fcvenilirlik i\u00e7in \u00f6nemlidir.<\/p>\n<h3>7. Aksesuarlar<\/h3>\n<p>Bir\u00e7ok MCCB, a\u015fa\u011f\u0131dakiler gibi aksesuarlar\u0131 destekler:<\/p>\n<ul>\n<li>yard\u0131mc\u0131 kontaklar<\/li>\n<li>\u015f\u00f6nt a\u00e7t\u0131r\u0131c\u0131lar<\/li>\n<li>d\u00fc\u015f\u00fck voltaj serbest b\u0131rakmalar\u0131<\/li>\n<li>motor operat\u00f6rleri<\/li>\n<li>alarm kontaklar\u0131<\/li>\n<\/ul>\n<p>Bunlar, devre kesiciyi basit bir koruma cihaz\u0131ndan daha geni\u015f bir kontrol ve izleme sisteminin par\u00e7as\u0131 haline getirir.<\/p>\n<p>Aksesuarlar uygulaman\u0131z i\u00e7in merkezi \u00f6neme sahipse, yard\u0131mc\u0131 kontaklar ve \u015f\u00f6nt a\u00e7t\u0131rma i\u015flevleri gibi ilgili uzmanl\u0131k konular\u0131 ayr\u0131 olarak ele al\u0131nmaya de\u011ferdir.<\/p>\n<h2>Anlaman\u0131z Gereken Temel MCCB De\u011ferleri<\/h2>\n<figure style=\"text-align: center;\"><img decoding=\"async\" src=\"https:\/\/img.viox.com\/Technical-infographic-showing-key-MCCB-ratings-including-Icu-Ics-and-LSIG-trip-functions.webp\" alt=\"Technical infographic showing key MCCB ratings including Icu Ics and LSIG trip functions\" \/><figcaption><em>Kritik MCCB de\u011ferlerine kapsaml\u0131 genel bak\u0131\u015f, Icu, Ics kesme kapasitelerini ve elektronik a\u00e7ma e\u011frisi i\u015flevlerini detayland\u0131r\u0131r.<\/em><\/figcaption><\/figure>\n<p>M\u00fchendislerin basit devre kesici tart\u0131\u015fmalar\u0131ndan MCCB'ye \u00f6zg\u00fc i\u00e7eri\u011fe ge\u00e7mesinin bir nedeni, de\u011ferlerin \u00e7ok daha \u00f6nemli hale gelmesidir.<\/p>\n<h3>Anma Ak\u0131m\u0131<\/h3>\n<p>Bu, devre kesicinin tan\u0131ml\u0131 ko\u015fullar alt\u0131nda ta\u015f\u0131mas\u0131 ama\u00e7lanan ak\u0131md\u0131r. \u0130nsanlar\u0131n bakt\u0131\u011f\u0131 ilk de\u011ferlerden biridir, ancak \u00f6nemli olan tek de\u011fer de\u011fildir.<\/p>\n<h3>\u00c7er\u00e7eve Boyutu<\/h3>\n<p>\u00c7er\u00e7eve, fiziksel devre kesici platformunu ve ak\u0131m zarf\u0131n\u0131 olu\u015fturur. Ayn\u0131 \u00e7er\u00e7eve ailesi i\u00e7inde farkl\u0131 a\u00e7ma ayarlar\u0131 mevcut olabilir.<\/p>\n<h3>Gerilim De\u011ferlendirmesi<\/h3>\n<p>Devre kesici, sistem voltaj\u0131na ve ilgili yerlerde AC veya DC uygunlu\u011fu dahil olmak \u00fczere uygulama ba\u011flam\u0131na uygun olmal\u0131d\u0131r.<\/p>\n<h3>Kutuplu Say\u0131s\u0131<\/h3>\n<p>Yayg\u0131n kutup yap\u0131land\u0131rmalar\u0131 \u015funlar\u0131 i\u00e7erir:<\/p>\n<ul>\n<li>2 kutuplu<\/li>\n<li>3 kutuplu<\/li>\n<li>4 kutuplu<\/li>\n<\/ul>\n<p>Kutuplu say\u0131s\u0131 se\u00e7imi, sistem mimarisine, iletken anahtarlama gereksinimlerine ve n\u00f6tr i\u015flemine ba\u011fl\u0131d\u0131r.<\/p>\n<h3>Kesme Kapasitesi<\/h3>\n<p>Bu, en \u00f6nemli MCCB parametrelerinden biridir. Devre kesici, kurulum noktas\u0131nda mevcut olan olas\u0131 ar\u0131za ak\u0131m\u0131n\u0131 kesebilmelidir.<\/p>\n<p>Temel terimler genellikle \u015funlar\u0131 i\u00e7erir:<\/p>\n<ul>\n<li><code>Icu<\/code><\/li>\n<li><code>Ics<\/code><\/li>\n<\/ul>\n<p>Bu de\u011ferler, devre kesicinin kurulumun ger\u00e7ek ar\u0131za seviyesi ve hizmet beklentisi i\u00e7in uygun olup olmad\u0131\u011f\u0131n\u0131 etkiler.<\/p>\n<p>Daha odakl\u0131 bir tart\u0131\u015fma i\u00e7in bkz. <a href=\"https:\/\/test.viox.com\/tr\/how-to-read-mccb-nameplates-for-electrical-safety\/\">Elektrik G\u00fcvenli\u011fi i\u00e7in MCCB \u0130sim Plakalar\u0131 Nas\u0131l Okunur<\/a>.<\/p>\n<h3>A\u00e7ma \u00dcnitesi Tipi<\/h3>\n<p>A\u00e7ma \u00fcnitesi mimarisi, a\u015fa\u011f\u0131dakileri g\u00fc\u00e7l\u00fc bir \u015fekilde etkiler:<\/p>\n<ul>\n<li>ayarlanabilirlik<\/li>\n<li>koordinasyon<\/li>\n<li>tekrarlanabilirlik<\/li>\n<li>izleme potansiyeli<\/li>\n<\/ul>\n<p>Bu nedenle, bir MCCB k\u0131lavuzu, temel d\u00fczeyde bile a\u00e7ma \u00fcnitesi tipinden bahsetmelidir.<\/p>\n<h2>Yayg\u0131n MCCB T\u00fcrleri<\/h2>\n<p>MCCB'leri s\u0131n\u0131fland\u0131rman\u0131n \u00e7e\u015fitli yararl\u0131 yollar\u0131 vard\u0131r. Pratik bir k\u0131lavuz, s\u0131n\u0131fland\u0131rmay\u0131 basit tutmal\u0131d\u0131r.<\/p>\n<h3>A\u00e7ma Teknolojisine G\u00f6re<\/h3>\n<ul>\n<li>termal-manyetik MCCB<\/li>\n<li>elektronik MCCB<\/li>\n<\/ul>\n<p>Bu, ger\u00e7ek projelerde genellikle en anlaml\u0131 s\u0131n\u0131fland\u0131rmad\u0131r, \u00e7\u00fcnk\u00fc ayarlar\u0131, do\u011frulu\u011fu ve koordinasyonu do\u011frudan etkiler. Bir sistem se\u00e7ici koordinasyon, daha s\u0131k\u0131 ayar kontrol\u00fc veya daha geli\u015fmi\u015f koruma mant\u0131\u011f\u0131 gerektirdi\u011finde, konu\u015fma genellikle basit sabit a\u00e7ma devre kesici se\u00e7imi yerine elektronik a\u00e7ma \u00fcnitelerine ve bunlar\u0131n TCC davran\u0131\u015f\u0131na do\u011fru kayar.<\/p>\n<h3>Uygulama G\u00f6revine G\u00f6re<\/h3>\n<p>Baz\u0131 MCCB'ler basit besleyici korumas\u0131 i\u00e7in se\u00e7ilirken, di\u011ferleri uygulama \u015funlar\u0131 gerektirdi\u011fi i\u00e7in se\u00e7ilir:<\/p>\n<ul>\n<li>daha y\u00fcksek kesme performans\u0131<\/li>\n<li>daha ayarlanabilir a\u00e7ma davran\u0131\u015f\u0131<\/li>\n<li>daha g\u00fc\u00e7l\u00fc koordinasyon deste\u011fi<\/li>\n<li>aksesuar entegrasyonu<\/li>\n<\/ul>\n<h3>Montaj ve Sistem Entegrasyonuna G\u00f6re<\/h3>\n<p>\u00dcreticiye ve sisteme ba\u011fl\u0131 olarak, MCCB'ler panolara, \u015falt cihazlar\u0131na, makine aksamlar\u0131na veya \u00f6zel koruyucu b\u00f6lmelere entegre edilebilir.<\/p>\n<p>\u00c7o\u011fu okuyucu i\u00e7in yararl\u0131 soru \u201cKa\u00e7 MCCB t\u00fcr\u00fc var?\u201d de\u011fil, daha ziyade:<\/p>\n<p><strong>Hangi a\u00e7ma teknolojisi, de\u011fer s\u0131n\u0131f\u0131 ve aksesuar seti uygulamama uygun?<\/strong><\/p>\n<h2>MCCB'ler Nerede Kullan\u0131l\u0131r?<\/h2>\n<p>MCCB'ler, al\u00e7ak gerilim ticari ve end\u00fcstriyel sistemlerde yayg\u0131n olarak kullan\u0131lmaktad\u0131r. Tipik uygulamalar \u015funlar\u0131 i\u00e7erir:<\/p>\n<ul>\n<li>al\u00e7ak gerilim da\u011f\u0131t\u0131m panosundan ana giden besleyiciler<\/li>\n<li>alt da\u011f\u0131t\u0131m ve pano besleyicileri<\/li>\n<li>motor ve makine besleme devreleri<\/li>\n<li>HVAC da\u011f\u0131t\u0131m\u0131<\/li>\n<li>jenerat\u00f6r besleyici korumas\u0131<\/li>\n<li>transferle ilgili g\u00fc\u00e7 da\u011f\u0131t\u0131m aksamlar\u0131<\/li>\n<li>MCB kapasitesinin yeterli olmad\u0131\u011f\u0131 daha b\u00fcy\u00fck bran\u015f devreleri<\/li>\n<\/ul>\n<p>Bunun bir nedeni de <code>mccb'ler<\/code> sorgusunun, s\u0131radan konut kullan\u0131c\u0131lar\u0131ndan ziyade m\u00fchendisleri, pano \u00fcreticilerini ve sat\u0131n alma ekiplerini \u00e7ekme e\u011filiminde olmas\u0131d\u0131r. MCCB'ler genellikle sistem g\u00f6revinin daha y\u00fcksek oldu\u011fu ve k\u00f6t\u00fc se\u00e7imlerin sonu\u00e7lar\u0131n\u0131n daha ciddi oldu\u011fu yerlerde g\u00f6r\u00fcn\u00fcr.<\/p>\n<h2>MCCB - MCB Kar\u015f\u0131la\u015ft\u0131rmas\u0131: K\u0131sa Bir Pratik Kar\u015f\u0131la\u015ft\u0131rma<\/h2>\n<p>Bu sayfa temel fark\u0131 a\u00e7\u0131klamal\u0131, ancak \u00f6zel kar\u015f\u0131la\u015ft\u0131rma sayfas\u0131n\u0131n yerini almamal\u0131d\u0131r.<\/p>\n<table style=\"border-collapse: collapse; width: 100%; text-align: left;\" border=\"1\">\n<thead>\n<tr>\n<th style=\"padding: 8px;\">\u00d6zellik<\/th>\n<th style=\"padding: 8px;\">MCCB'N\u0130N<\/th>\n<th style=\"padding: 8px;\">MCB&#039;N\u0130N<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"padding: 8px;\">Tipik rol<\/td>\n<td style=\"padding: 8px;\">Besleyici ve daha y\u00fcksek g\u00f6revli bran\u015fman korumas\u0131<\/td>\n<td style=\"padding: 8px;\">Daha k\u00fc\u00e7\u00fck nihai devreler<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px;\">Ak\u0131m aral\u0131\u011f\u0131<\/td>\n<td style=\"padding: 8px;\">Daha geni\u015f ve daha y\u00fcksek<\/td>\n<td style=\"padding: 8px;\">Daha d\u00fc\u015f\u00fck ve daha s\u0131n\u0131rl\u0131<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px;\">Kesme kapasitesi<\/td>\n<td style=\"padding: 8px;\">Genellikle daha y\u00fcksek<\/td>\n<td style=\"padding: 8px;\">Genellikle daha d\u00fc\u015f\u00fck<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px;\">A\u00e7ma ayar\u0131 esnekli\u011fi<\/td>\n<td style=\"padding: 8px;\">Genellikle daha geni\u015f<\/td>\n<td style=\"padding: 8px;\">Genellikle daha basit<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px;\">Uygulamalar<\/td>\n<td style=\"padding: 8px;\">Ticari ve end\u00fcstriyel da\u011f\u0131t\u0131m<\/td>\n<td style=\"padding: 8px;\">Konut ve daha hafif g\u00f6revli bran\u015fman devreleri<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Pratik \u00e7\u0131kar\u0131m basittir:<\/p>\n<ul>\n<li>se\u00e7in <a href=\"https:\/\/test.viox.com\/tr\/mcb\/\">MCB&#039;N\u0130N<\/a> daha k\u00fc\u00e7\u00fck nihai devreler i\u00e7in<\/li>\n<li>g\u00f6rev seviyesi, ar\u0131za seviyesi veya koruma esnekli\u011fi bu aral\u0131\u011f\u0131n \u00f6tesine ge\u00e7ti\u011finde MCCB'yi se\u00e7in<\/li>\n<\/ul>\n<p>\u00d6zel kar\u015f\u0131la\u015ft\u0131rma i\u00e7in bkz. <a href=\"https:\/\/test.viox.com\/tr\/mccb-vs-mcb\/\">MCCB vs MCB<\/a>.<\/p>\n<h2>Bir MCCB Nas\u0131l Se\u00e7ilir: \u00dcst D\u00fczey Se\u00e7im Mant\u0131\u011f\u0131<\/h2>\n<p>Bu sayfa okuyuculara \u00e7er\u00e7eveyi vermeli, ard\u0131ndan ayr\u0131nt\u0131l\u0131 boyutland\u0131rmay\u0131 \u00f6zel k\u0131lavuza b\u0131rakmal\u0131d\u0131r.<\/p>\n<p>\u00dcst d\u00fczeyde, MCCB se\u00e7imi \u015funlarla ba\u015flar:<\/p>\n<ol>\n<li>y\u00fck ak\u0131m\u0131<\/li>\n<li>sistem gerilimi<\/li>\n<li>kutup say\u0131s\u0131<\/li>\n<li>mevcut k\u0131sa devre ak\u0131m\u0131<\/li>\n<li>gerekli kesme kapasitesi<\/li>\n<li>a\u00e7ma \u00fcnitesi tipi<\/li>\n<li>aksesuar ve kontrol gereksinimleri<\/li>\n<li>yukar\u0131 ve a\u015fa\u011f\u0131 ak\u0131\u015f cihazlar\u0131yla koordinasyon<\/li>\n<\/ol>\n<p>Bu, temel bilgiler sayfas\u0131 i\u00e7in yeterlidir.<br \/>\nOkuyucu zaten ger\u00e7ek bir panoyu boyutland\u0131r\u0131yorsa, \u00f6zel k\u0131lavuza daha derinlemesine girmelidir: <a href=\"https:\/\/test.viox.com\/tr\/how-to-select-an-mccb-for-a-panel\/\">Bir Panele MCCB Nas\u0131l Se\u00e7ilir<\/a>.<\/p>\n<h2>Kurulum, Bak\u0131m ve Test Temelleri<\/h2>\n<p>MCCB'ler genellikle dayan\u0131kl\u0131, d\u00fc\u015f\u00fck bak\u0131m gerektiren cihazlar olarak kabul edilir, ancak bu \u201conlar\u0131 sonsuza kadar g\u00f6rmezden gelin\u201d ile kar\u0131\u015ft\u0131r\u0131lmamal\u0131d\u0131r.\u201d<\/p>\n<p>Temel d\u00fczeyde, iyi uygulama \u015funlar\u0131 i\u00e7erir:<\/p>\n<ul>\n<li>do\u011fru iletken ve terminal e\u015fle\u015fmesi<\/li>\n<li>uygun tork uygulamas\u0131<\/li>\n<li>y\u00fckl\u00fc ba\u011flant\u0131lar\u0131n termal incelemesi<\/li>\n<li>hasar veya a\u015f\u0131r\u0131 \u0131s\u0131nma i\u00e7in g\u00f6rsel inceleme<\/li>\n<li>kurulum i\u00e7in uygun periyodik fonksiyonel kontroller<\/li>\n<\/ul>\n<p>Elektronik a\u00e7ma \u00fcniteli kesiciler i\u00e7in, test ve do\u011frulama basit bir mekanik kontrol\u00fcn \u00f6tesine ge\u00e7ebilir. Uygun bir bak\u0131m plan\u0131 \u015funlara ba\u011fl\u0131d\u0131r:<\/p>\n<ul>\n<li>kesici g\u00f6revi<\/li>\n<li>ar\u0131za ge\u00e7mi\u015fi<\/li>\n<li>sistemin kritikli\u011fi<\/li>\n<li>\u00fcretici rehberli\u011fi<\/li>\n<\/ul>\n<p>Bu k\u0131lavuzun yaln\u0131zca testin \u00f6nemli oldu\u011funu belirtmesi gerekir. \u00d6zel test sayfas\u0131 olmas\u0131na gerek yoktur.<\/p>\n<h2>\u0130nsanlar\u0131n MCCB'lerle Yapt\u0131\u011f\u0131 Yayg\u0131n Hatalar<\/h2>\n<h3>1. Ak\u0131m De\u011ferini Tek Se\u00e7im Fakt\u00f6r\u00fc Olarak Ele Alma<\/h3>\n<p>Ak\u0131m de\u011feri \u00f6nemlidir, ancak kesme kapasitesi, a\u00e7ma \u00fcnitesi tipi veya koordinasyonu uygun de\u011filse, bir MCCB yine de yanl\u0131\u015f olabilir.<\/p>\n<h3>2. Bir MCB'nin Yeterli Olaca\u011f\u0131 Yerde Bir MCCB Kullanma<\/h3>\n<p>A\u015f\u0131r\u0131 koruma belirtmek, ger\u00e7ek de\u011fer katmadan b\u00fct\u00e7e ve alan\u0131 bo\u015fa harcayabilir.<\/p>\n<h3>3. Bir MCCB'nin Gerekli Oldu\u011fu Yerde Bir MCB Kullanma<\/h3>\n<p>Bu, z\u0131t hatad\u0131r ve genellikle daha tehlikelisidir. Daha y\u00fcksek ar\u0131za g\u00f6revi, daha b\u00fcy\u00fck besleyiciler ve daha zorlu uygulamalar genellikle MCCB d\u00fczeyinde koruma gerektirir.<\/p>\n<h3>4. A\u00e7ma \u00dcnitesi Teknolojisini G\u00f6z Ard\u0131 Etme<\/h3>\n<p>A\u00e7ma \u00fcnitesi se\u00e7imi yaln\u0131zca koruma performans\u0131n\u0131 de\u011fil, ayn\u0131 zamanda ayarlanabilirli\u011fi ve se\u00e7icili\u011fi de etkiler.<\/p>\n<h3>5. Tip Plakas\u0131 \u0130ncelemesini Atlamak<\/h3>\n<p>Bir\u00e7ok se\u00e7im hatas\u0131, kesici etiketinin tam olarak anla\u015f\u0131lmamas\u0131ndan kaynaklan\u0131r. Kesme kapasitesi, \u00e7er\u00e7eve ve a\u00e7ma detaylar\u0131 \u00f6nemlidir.<\/p>\n<h2>S\u0131k\u00e7a Sorulan Sorular<\/h2>\n<h3>Kompakt \u015falter nedir?<\/h3>\n<p>Bir kompakt \u015falter, kal\u0131planm\u0131\u015f bir yal\u0131t\u0131m muhafazas\u0131 i\u00e7ine yerle\u015ftirilmi\u015f al\u00e7ak gerilim a\u015f\u0131r\u0131 ak\u0131m koruma cihaz\u0131d\u0131r. Ak\u0131m seviyesi, ar\u0131za ak\u0131m\u0131 veya a\u00e7ma esnekli\u011finin bir minyat\u00fcr \u015falterin pratik aral\u0131\u011f\u0131n\u0131 a\u015ft\u0131\u011f\u0131 besleyici ve daha y\u00fcksek g\u00fc\u00e7l\u00fc bran\u015fman korumas\u0131 i\u00e7in kullan\u0131l\u0131r.<\/p>\n<h3>MCCB ve MCB aras\u0131ndaki fark nedir?<\/h3>\n<p>Bir MCCB genellikle daha b\u00fcy\u00fck devreler, daha y\u00fcksek ar\u0131za seviyeleri ve daha zorlu koruma g\u00f6revleri i\u00e7in kullan\u0131l\u0131rken, bir MCB genellikle daha basit koruma gereksinimleri olan daha k\u00fc\u00e7\u00fck son devreler i\u00e7in kullan\u0131l\u0131r.<\/p>\n<h3>Bir MCCB'nin i\u00e7inde neler bulunur?<\/h3>\n<p>Tipik bir MCCB, kal\u0131planm\u0131\u015f bir yal\u0131t\u0131m kasas\u0131, sabit ve hareketli kontaklar, bir \u00e7al\u0131\u015ft\u0131rma mekanizmas\u0131, bir a\u00e7ma \u00fcnitesi, ark kontrol bile\u015fenleri, terminaller ve genellikle yard\u0131mc\u0131 kontaklar veya \u015f\u00f6nt a\u00e7\u0131c\u0131lar gibi iste\u011fe ba\u011fl\u0131 aksesuarlar i\u00e7erir.<\/p>\n<h3>MCCB'ler nerelerde kullan\u0131l\u0131r?<\/h3>\n<p>MCCB'ler genellikle al\u00e7ak gerilim ticari ve end\u00fcstriyel da\u011f\u0131t\u0131m sistemlerinde, besleyiciler, makine devreleri, tali da\u011f\u0131t\u0131m panolar\u0131 ve daha b\u00fcy\u00fck bran\u015fman devreleri dahil olmak \u00fczere yayg\u0131n olarak kullan\u0131l\u0131r.<\/p>\n<h3>MCCB \u00fczerindeki Icu ve Ics ne anlama gelir?<\/h3>\n<p>Bunlar, kesicinin sistemdeki mevcut k\u0131sa devre ak\u0131m\u0131na ve beklenen servis g\u00f6revine uygun olup olmad\u0131\u011f\u0131n\u0131 belirlemeye yard\u0131mc\u0131 olan kesme kapasitesiyle ilgili de\u011ferlerdir.<\/p>\n<h3>Her MCCB elektronik midir?<\/h3>\n<p>MCCB'ler, uygulama ve \u00fcr\u00fcn ailesine ba\u011fl\u0131 olarak termal-manyetik veya elektronik a\u00e7ma teknolojisi kullanabilir.<\/p>\n<h3>Do\u011fru MCCB'yi nas\u0131l se\u00e7erim?<\/h3>\n<p>Tesisat\u0131n ak\u0131m, gerilim, kutup say\u0131s\u0131, mevcut ar\u0131za seviyesi, kesme kapasitesi, a\u00e7ma \u00fcnitesi tipi ve koordinasyon gereksinimlerini e\u015fle\u015ftirerek do\u011fru MCCB'yi se\u00e7ersiniz.<\/p>\n<h2>Sonu\u00e7<\/h2>\n<p>En net cevab\u0131 istiyorsan\u0131z <code>kal\u0131pl\u0131 kasa devre kesici nedir<\/code>, i\u015fte bu:<\/p>\n<p><strong>Bir MCCB, ak\u0131m seviyesi, ar\u0131za seviyesi veya a\u00e7ma esnekli\u011finin minyat\u00fcr bir kesicinin normal \u00e7al\u0131\u015fma aral\u0131\u011f\u0131n\u0131 a\u015ft\u0131\u011f\u0131 besleyiciler ve daha y\u00fcksek g\u00f6revli bran\u015fman devreleri i\u00e7in d\u00fc\u015f\u00fck voltajl\u0131 bir devre kesicidir.<\/strong><\/p>\n<p>Bu ayn\u0131 zamanda bu sayfan\u0131n \u015fundan ayr\u0131 olarak var olmas\u0131n\u0131n nedenidir:<\/p>\n<ul>\n<li>ana <a href=\"https:\/\/test.viox.com\/tr\/mccb\/\">MCCB \u00fcr\u00fcn sayfas\u0131<\/a><\/li>\n<li>ana <a href=\"https:\/\/test.viox.com\/tr\/mccb-vs-mcb\/\">MCCB - MCB kar\u015f\u0131la\u015ft\u0131rma sayfas\u0131<\/a><\/li>\n<li>ana <a href=\"https:\/\/test.viox.com\/tr\/how-to-select-an-mccb-for-a-panel\/\">MCCB se\u00e7im k\u0131lavuzumuza bak\u0131n<\/a><\/li>\n<li>ana <a href=\"https:\/\/test.viox.com\/tr\/mccb-full-form-molded-case-circuit-breaker\/\">MCCB tam form sayfas\u0131<\/a><\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<\/div>\n<div class=\"simg-pop-btn\" style=\"top: 5915.77px; left: 54.0078px; display: none;\"><\/div>\n<div class=\"simg-pop-btn\" style=\"top: 5915.77px; left: 54.0078px; display: none;\"><\/div>\n<div class=\"simg-pop-btn\" style=\"top: 79.8281px; left: 54.0078px; display: none;\"><\/div>\n<div class=\"simg-pop-btn\" style=\"top: 79.8281px; left: 54.0078px; display: none;\"><\/div>\n<div class=\"simg-pop-btn\" style=\"top: 79.8281px; left: 54.0078px; display: none;\"><\/div>","protected":false},"excerpt":{"rendered":"<p>Direct Answer A heavy-duty molded case circuit breaker (MCCB) safely installed within a low-voltage industrial distribution panel, ready to protect distribution equipment. A molded case circuit breaker (MCCB) is a low-voltage circuit breaker used to protect feeders, larger branch circuits, machinery supplies, and distribution equipment against overloads and short circuits. Compared with a smaller MCB, [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":7121,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1],"tags":[],"class_list":["post-7120","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"_links":{"self":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/posts\/7120","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/comments?post=7120"}],"version-history":[{"count":4,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/posts\/7120\/revisions"}],"predecessor-version":[{"id":23291,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/posts\/7120\/revisions\/23291"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/media\/7121"}],"wp:attachment":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/media?parent=7120"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/categories?post=7120"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/tags?post=7120"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}