{"id":21129,"date":"2026-01-01T11:06:34","date_gmt":"2026-01-01T03:06:34","guid":{"rendered":"https:\/\/viox.com\/?p=21129"},"modified":"2026-01-01T11:33:28","modified_gmt":"2026-01-01T03:33:28","slug":"arc-flash-labels-generic-vs-detailed-nec-nfpa-guide","status":"publish","type":"post","link":"https:\/\/test.viox.com\/tr\/arc-flash-labels-generic-vs-detailed-nec-nfpa-guide\/","title":{"rendered":"Genel Uyar\u0131lara Kar\u015f\u0131 Detayl\u0131 Veriler: Ekipman\u0131n\u0131z Ger\u00e7ekten Hangi Ark Parlamas\u0131 Etiketine \u0130htiya\u00e7 Duyuyor?"},"content":{"rendered":"<div class=\"product-intro\">\n<h2>Yeni VIOX Ekipman\u0131n\u0131z Neden Genel Bir Uyar\u0131 Etiketiyle Geliyor (Ve Bu Neden Asl\u0131nda Do\u011fru)<\/h2>\n<p>Yeni bir VIOX \u015falt cihaz\u0131 veya <a href=\"https:\/\/test.viox.com\/tr\/mcb-vs-mlo-panelboard-selection-guide\/\">panosu<\/a>, ambalaj\u0131n\u0131 a\u00e7t\u0131\u011f\u0131n\u0131zda, \u00fczerinde \u201cTehlike \u2013 Ark Parlamas\u0131 ve \u015eok Tehlikesi\u201d yazan parlak sar\u0131 bir uyar\u0131 etiketi g\u00f6rebilirsiniz. Baz\u0131 m\u00fc\u015fteriler soruyor: \u201cSpesifik olay enerjisi verileri nerede? Elektrik\u00e7ilerim hangi KKD kategorisini giymeli? VIOX bir \u015feyi atlad\u0131 m\u0131?\u201d<\/p>\n<p>K\u0131sa cevap: Kesinlikle hay\u0131r. VIOX fabrikada ayr\u0131nt\u0131l\u0131 ark parlamas\u0131 hesaplamalar\u0131 ekleseydi, temel g\u00fcvenlik prensiplerini ihlal ediyor ve potansiyel olarak \u00e7al\u0131\u015fanlar\u0131n\u0131z\u0131 yanl\u0131\u015f tehlike bilgilerine maruz b\u0131rak\u0131yor olurduk. Bu makale, iki t\u00fcr ark parlamas\u0131 etiketi aras\u0131ndaki kritik ayr\u0131m\u0131 a\u00e7\u0131kl\u0131\u011fa kavu\u015fturuyor, her birinin arkas\u0131ndaki yasal sorumluluklar\u0131 a\u00e7\u0131kl\u0131yor ve VIOX'un tam olarak ne sa\u011flad\u0131\u011f\u0131n\u0131 ve sizin sahada ne belirlemeniz gerekti\u011fini g\u00f6steriyor.<\/p>\n<figure style=\"text-align: center; margin: 20px 0;\"><img decoding=\"async\" style=\"max-width: 100%; height: auto;\" src=\"https:\/\/img.viox.com\/VIOX-electrical-switchgear-with-NEC-compliant-generic-arc-flash-warning-label-on-panel-doorpdf.webp\" alt=\"VIOX electrical switchgear with NEC-compliant generic arc flash warning label on panel door\" \/><figcaption style=\"font-style: italic; color: #555; margin-top: 8px;\">Panel kap\u0131s\u0131nda NEC uyumlu genel ark parlamas\u0131 uyar\u0131 etiketi bulunan VIOX elektrik \u015falt cihaz\u0131<\/figcaption><\/figure>\n<h2>\u0130ki T\u00fcr <a href=\"https:\/\/test.viox.com\/tr\/what-is-an-arc-in-a-circuit-breaker\/\">Ark Parlamas\u0131<\/a> Etiket: Temel Fark\u0131 Anlamak<\/h2>\n<p>Kafa kar\u0131\u015f\u0131kl\u0131\u011f\u0131, farkl\u0131 standartlar taraf\u0131ndan y\u00f6netilen tamamen ayr\u0131 iki etiketleme gereksinimini kar\u0131\u015ft\u0131rmaktan kaynaklan\u0131yor. Bunlar\u0131 par\u00e7alayal\u0131m:<\/p>\n<h3>Genel Uyar\u0131 Etiketleri (NEC 110.16)<\/h3>\n<p>Bu etiketler, Ulusal Elektrik Kodu taraf\u0131ndan gerekli k\u0131l\u0131nan evrensel tehlike uyar\u0131lar\u0131 olarak hizmet eder. 2026 NEC itibar\u0131yla, B\u00f6l\u00fcm 110.16, enerjili haldeyken incelenmesi, ayarlanmas\u0131, servis edilmesi veya bak\u0131m\u0131 gerekebilecek konut birimleri d\u0131\u015f\u0131ndaki yerlerdeki elektrikli ekipmanlarda kal\u0131c\u0131 ark parlamas\u0131 tehlike i\u015faretlerini zorunlu k\u0131lar.<\/p>\n<p><strong>Temel \u00f6zellikler:<\/strong><\/p>\n<ul>\n<li><strong>Amac\u0131m\u0131z:<\/strong> \u00c7al\u0131\u015fanlar\u0131 ark parlamas\u0131 ve \u015fok tehlikelerinin mevcut olabilece\u011fi konusunda uyar\u0131n<\/li>\n<li><strong>Gerekli bilgiler:<\/strong> Genel uyar\u0131 (hesaplama gerekmez)<\/li>\n<li><strong>Sorumluluk:<\/strong> Teknik olarak kurulumcunun g\u00f6revi, ancak VIOX gibi sayg\u0131n \u00fcreticiler bunlar\u0131 standart olarak dahil eder<\/li>\n<li><strong>Uyumluluk standard\u0131:<\/strong> NEC 110.16 (\u015fimdi 2026 bask\u0131s\u0131nda \u00f6nemli \u00f6l\u00e7\u00fcde geni\u015fletildi)<\/li>\n<\/ul>\n<p>2026 NEC b\u00fcy\u00fck bir de\u011fi\u015fimi temsil ediyor\u2014ark parlamas\u0131 etiketleri art\u0131k sadece \u00f6nerilen uygulama de\u011fil, kodla zorunlu hale getirildi. Bu, \u015falt panolar\u0131, \u015falt cihazlar\u0131, panolar, motor kontrol merkezleri ve end\u00fcstriyel kontrol panolar\u0131 i\u00e7in ge\u00e7erlidir.<\/p>\n<h3>Ayr\u0131nt\u0131l\u0131 Ark Parlamas\u0131 Etiketleri (NFPA 70E 130.5(H))<\/h3>\n<p>Bu etiketler, sahaya \u00f6zg\u00fc elektrik sistemi analizine dayal\u0131 olarak belirli tehlike verileri sa\u011flar. NFPA 70E B\u00f6l\u00fcm 130.5(H), uygulanabilir g\u00fcvenlik bilgileri i\u00e7eren ekipman etiketlemesi gerektirir.<\/p>\n<p><strong>Temel \u00f6zellikler:<\/strong><\/p>\n<ul>\n<li><strong>Amac\u0131m\u0131z:<\/strong> Kurulu oldu\u011fu konumdaki belirli ekipman i\u00e7in kesin tehlike seviyeleri ve KKD gereksinimleri sa\u011flay\u0131n<\/li>\n<li><strong>Gerekli bilgiler:<\/strong> Olay enerjisi (cal\/cm\u00b2), ark parlamas\u0131 s\u0131n\u0131r mesafesi, KKD kategorisi veya gerekli ark derecesi, nominal sistem voltaj\u0131 ve de\u011ferlendirme tarihi<\/li>\n<li><strong>Sorumluluk:<\/strong> Ekipman sahibi (tesisiniz)<\/li>\n<li><strong>Uyumluluk standard\u0131:<\/strong> NFPA 70E (i\u015fyeri g\u00fcvenli\u011fi standard\u0131)<\/li>\n<\/ul>\n<figure style=\"text-align: center; margin: 20px 0;\"><img decoding=\"async\" style=\"max-width: 100%; height: auto;\" src=\"https:\/\/img.viox.com\/Comparison-diagram-showing-NEC-generic-warning-label-versus-NFPA-70E-detailed-arc-flash-label-requirements.webp\" alt=\"Comparison diagram showing NEC generic warning label versus NFPA 70E detailed arc flash label requirements\" \/><figcaption style=\"font-style: italic; color: #555; margin-top: 8px;\">NEC genel uyar\u0131 etiketi ile NFPA 70E ayr\u0131nt\u0131l\u0131 ark parlamas\u0131 etiketi gereksinimlerini g\u00f6steren kar\u015f\u0131la\u015ft\u0131rma diyagram\u0131<\/figcaption><\/figure>\n<h3>Kar\u015f\u0131la\u015ft\u0131rma Tablosu: \u0130ki Etiket, \u0130ki Ama\u00e7<\/h3>\n<table style=\"border-collapse: collapse; width: 100%; margin-bottom: 20px;\" border=\"1\" cellspacing=\"0\" cellpadding=\"10\">\n<thead>\n<tr style=\"background-color: #f2f2f2;\">\n<th>G\u00f6r\u00fcn\u00fc\u015f<\/th>\n<th>Genel Uyar\u0131 Etiketi (NEC 110.16)<\/th>\n<th>Ayr\u0131nt\u0131l\u0131 Ark Parlamas\u0131 Etiketi (NFPA 70E 130.5(H))<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>Birincil Ama\u00e7<\/strong><\/td>\n<td>Potansiyel tehlike varl\u0131\u011f\u0131 konusunda uyar\u0131n<\/td>\n<td>Belirli koruyucu \u00f6nlemler sa\u011flay\u0131n<\/td>\n<\/tr>\n<tr>\n<td><strong>Bilgi \u0130\u00e7eri\u011fi<\/strong><\/td>\n<td>\u201cTehlike\/Uyar\u0131 \u2013 Ark Parlamas\u0131 Tehlikesi\u201d<\/td>\n<td>Olay enerjisi, s\u0131n\u0131r, KKD kategorisi, voltaj, tarih<\/td>\n<\/tr>\n<tr>\n<td><strong>Kim Uygular<\/strong><\/td>\n<td>\u00dcretici veya kurulumcu<\/td>\n<td>Ekipman sahibi (devreye almadan sonra)<\/td>\n<\/tr>\n<tr>\n<td><strong>Ne Zaman Uygulan\u0131r<\/strong><\/td>\n<td>\u00dcretim veya kurulum s\u0131ras\u0131nda<\/td>\n<td>Sistem enerjilendikten ve ark parlamas\u0131 \u00e7al\u0131\u015fmas\u0131ndan sonra<\/td>\n<\/tr>\n<tr>\n<td><strong>Gerekli Hesaplama<\/strong><\/td>\n<td>Hay\u0131r<\/td>\n<td>Evet (IEEE 1584 analizi)<\/td>\n<\/tr>\n<tr>\n<td><strong>G\u00fcncelleme S\u0131kl\u0131\u011f\u0131<\/strong><\/td>\n<td>Kal\u0131c\u0131 (ekipman de\u011fi\u015fmedi\u011fi s\u00fcrece)<\/td>\n<td>Her 5 y\u0131lda bir veya sistem de\u011fi\u015fti\u011finde<\/td>\n<\/tr>\n<tr>\n<td><strong>Kod\/Standart<\/strong><\/td>\n<td>NEC 110.16 (kurulum kodu)<\/td>\n<td>NFPA 70E 130.5(H) (i\u015fyeri g\u00fcvenli\u011fi)<\/td>\n<\/tr>\n<tr>\n<td><strong>Yasal Sorumluluk<\/strong><\/td>\n<td>\u00dcretici\/y\u00fcklenici<\/td>\n<td>Tesis sahibi\/i\u015fveren<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>VIOX Gibi OEM \u00dcreticileri Neden Ayr\u0131nt\u0131l\u0131 Ark Parlamas\u0131 Verileri Sa\u011flayamaz<\/h2>\n<p>Bu, k\u00f6\u015feleri kesmekle ilgili de\u011fil\u2014bu, fizik ve g\u00fcvenlikle ilgili. Ayr\u0131nt\u0131l\u0131 ark parlamas\u0131 etiketleri, ekipman fabrikam\u0131zdan ayr\u0131ld\u0131\u011f\u0131nda mevcut olmayan tesisinizin elektrik altyap\u0131s\u0131na tamamen ba\u011fl\u0131 olan hesaplamalar gerektirir.<\/p>\n<h3>Fabrika Etiketlemesini \u0130mkans\u0131z K\u0131lan De\u011fi\u015fkenler<\/h3>\n<p><strong>1. Yukar\u0131 ak\u0131\u015f transformat\u00f6r \u00f6zellikleri<\/strong><br \/>\n\u015eebekenizin veya sahadaki transformat\u00f6r\u00fcn\u00fcz\u00fcn empedans\u0131, mevcut ar\u0131za ak\u0131m\u0131n\u0131 \u00f6nemli \u00f6l\u00e7\u00fcde etkiler. 5.75% empedansa sahip 1500 kVA'l\u0131k bir transformat\u00f6r, 3.5% empedansa sahip bir transformat\u00f6rden farkl\u0131 ar\u0131za seviyeleri \u00fcretir.<\/p>\n<p><strong>2. Kablo uzunlu\u011fu ve iletken boyutu<\/strong><br \/>\nElektriksel mesafe \u00f6nemlidir. VIOX ekipman\u0131n\u0131 transformat\u00f6rden 50 feet uza\u011fa kurmak, 500 feet uza\u011fa kurmaktan \u00e7ok farkl\u0131 olay enerjisi verir. Kablo empedans\u0131, mesafe boyunca mevcut ar\u0131za ak\u0131m\u0131n\u0131 azalt\u0131r.<\/p>\n<p><strong>3. \u015eebeke ar\u0131za ak\u0131m\u0131 verileri<\/strong><br \/>\n\u015eebeke \u015firketinizin servis noktas\u0131ndaki mevcut ar\u0131za ak\u0131m\u0131 sahaya \u00f6zeldir. Bu veri, tesisiniz \u015febekeye ba\u011flanana kadar mevcut de\u011fildir.<\/p>\n<p><strong>4. Koruyucu cihaz ayarlar\u0131<\/strong><br \/>\nYukar\u0131 ak\u0131\u015f\u0131n temizleme s\u00fcresi <a href=\"https:\/\/test.viox.com\/tr\/mccb\/\">k\u0131r\u0131c\u0131lar<\/a> veya <a href=\"https:\/\/test.viox.com\/tr\/fuse-vs-fuse-link-difference-guide\/\">Sigortalar<\/a> do\u011frudan olay enerjisi hesaplamalar\u0131n\u0131 etkiler. Sistem koruman\u0131z\u0131n nas\u0131l koordine edildi\u011fi, bir ark ar\u0131zas\u0131n\u0131n ne kadar s\u00fcreyle devam edece\u011fini etkiler.<\/p>\n<p><strong>5. \u00c7al\u0131\u015fma mesafesi<\/strong><br \/>\nFarkl\u0131 ekipman konfig\u00fcrasyonlar\u0131 ve bak\u0131m prosed\u00fcrleri, de\u011fi\u015fen \u00e7al\u0131\u015fma mesafelerine neden olur ve bu da \u00e7al\u0131\u015fan\u0131n bulundu\u011fu yerdeki olay enerjisi maruziyetini etkiler.<\/p>\n<figure style=\"text-align: center; margin: 20px 0;\"><img decoding=\"async\" style=\"max-width: 100%; height: auto;\" src=\"https:\/\/img.viox.com\/One-line-diagram-illustrating-site-specific-variables-affecting-arc-flash-incident-energy-calculations.webp\" alt=\"One-line diagram illustrating site-specific variables affecting arc flash incident energy calculations\" \/><figcaption style=\"font-style: italic; color: #555; margin-top: 8px;\">Ark parlamas\u0131 olay enerjisi hesaplamalar\u0131n\u0131 etkileyen sahaya \u00f6zg\u00fc de\u011fi\u015fkenleri g\u00f6steren tek hat \u015femas\u0131<\/figcaption><\/figure>\n<h3>IEEE 1584 Hesaplamalar\u0131 Ger\u00e7ekte Neyi Gerektirir<\/h3>\n<p>Ark parlamas\u0131 olay enerjisi hesaplamalar\u0131, a\u015fa\u011f\u0131dakileri gerektiren IEEE 1584 metodolojisini izler:<\/p>\n<ul>\n<li>\u00dc\u00e7 fazl\u0131 vidal\u0131 ar\u0131za ak\u0131m\u0131 (k\u0131sa devre \u00e7al\u0131\u015fmas\u0131ndan)<\/li>\n<li>Ekipman tipi ve muhafaza boyutlar\u0131<\/li>\n<li>\u0130letkenler aras\u0131ndaki bo\u015fluk<\/li>\n<li>\u00c7al\u0131\u015fma mesafesi<\/li>\n<li>Koruyucu cihaz a\u00e7ma s\u00fcresi (ak\u0131m-zaman koordinasyonundan)<\/li>\n<\/ul>\n<p>Bu parametrelerin hi\u00e7biri bo\u015flukta var olmaz. Bunlar ancak eksiksiz elektrik sisteminiz tasarland\u0131\u011f\u0131nda, kuruldu\u011funda ve enerji verildi\u011finde ortaya \u00e7\u0131kar.<\/p>\n<h2>NEC 2026 Oyun De\u011fi\u015ftirici: Geni\u015fletilmi\u015f Etiketleme Gereksinimleri<\/h2>\n<p>\u00d6nceki NEC s\u00fcr\u00fcmleri yaln\u0131zca 1200A veya daha y\u00fcksek de\u011ferdeki servis ekipmanlar\u0131nda etiket gerektiriyordu. 2026 NEC B\u00f6l\u00fcm 110.16 bu kapsam\u0131 \u00f6nemli \u00f6l\u00e7\u00fcde geni\u015fletiyor. Art\u0131k, konut d\u0131\u015f\u0131 yerlerde enerji varken servis edilebilecek neredeyse t\u00fcm elektrikli ekipmanlarda ark parlamas\u0131 tehlike i\u015faretleri bulunmas\u0131 gerekiyor.<\/p>\n<h3>NEC 2026'da Ne De\u011fi\u015fti<\/h3>\n<p>Yeni gereksinimler, etiketlerin \u015funlar\u0131 i\u00e7ermesi gerekti\u011fini belirtir:<\/p>\n<ol>\n<li>Nominal sistem voltaj\u0131<\/li>\n<li>Ark parlamas\u0131 s\u0131n\u0131r\u0131<\/li>\n<li>Mevcut olay enerjisi VEYA ark parlamas\u0131 KKD kategorisi (ikisi birden de\u011fil)<\/li>\n<li>De\u011ferlendirme tarihi<\/li>\n<\/ol>\n<p>Kritik olarak, bu etiketler kal\u0131c\u0131 olmal\u0131 ve NEC 110.21(B)'deki dayan\u0131kl\u0131l\u0131k standartlar\u0131n\u0131 kar\u015f\u0131lamal\u0131d\u0131r. El yaz\u0131s\u0131yla yaz\u0131lm\u0131\u015f etiketler art\u0131k uyumlu de\u011fildir.<\/p>\n<figure style=\"text-align: center; margin: 20px 0;\"><img decoding=\"async\" style=\"max-width: 100%; height: auto;\" src=\"https:\/\/img.viox.com\/Electrician-reviewing-detailed-NFPA-70E-arc-flash-label-on-VIOX-industrial-electrical-equipment-showing-incident-energy-and-PPE-requirements.webp\" alt=\"Electrician reviewing detailed NFPA 70E arc flash label on VIOX industrial electrical equipment showing incident energy and PPE requirements\" \/><figcaption style=\"font-style: italic; color: #555; margin-top: 8px;\">Elektrik\u00e7inin, olay enerjisini ve KKD gereksinimlerini g\u00f6steren VIOX end\u00fcstriyel elektrikli ekipman \u00fczerindeki ayr\u0131nt\u0131l\u0131 NFPA 70E ark parlamas\u0131 etiketini incelemesi<\/figcaption><\/figure>\n<h3>NFPA 70E ile Uyum<\/h3>\n<p>2026 NEC de\u011fi\u015fiklikleri, kurulum gereksinimlerini NFPA 70E i\u015fyeri g\u00fcvenli\u011fi standartlar\u0131yla daha yak\u0131ndan uyumlu hale getiriyor. Ancak, sorumluluk payla\u015f\u0131m\u0131 devam ediyor: NEC kurulum gereksinimlerini (genel uyar\u0131lar) y\u00f6netirken, NFPA 70E i\u015fyeri g\u00fcvenli\u011fi gereksinimlerini (ayr\u0131nt\u0131l\u0131 tehlike verileri) y\u00f6netir.<\/p>\n<h2>VIOX'un Sorumlulu\u011fu ve Sizin Sorumlulu\u011funuz: Net B\u00f6l\u00fcnme<\/h2>\n<p>Kimin ne yapt\u0131\u011f\u0131n\u0131 anlamak, kafa kar\u0131\u015f\u0131kl\u0131\u011f\u0131n\u0131 ortadan kald\u0131r\u0131r ve uyumlulu\u011fu sa\u011flar.<\/p>\n<h3>VIOX'un Sa\u011flad\u0131klar\u0131<\/h3>\n<p><strong>1. NEC uyumlu genel uyar\u0131 etiketleri<\/strong><br \/>\nHer VIOX \u015falt cihaz\u0131, panosu ve motor kontrol merkezi, NEC 110.16 gereksinimlerini kar\u015f\u0131layan fabrikada tak\u0131lm\u0131\u015f uyar\u0131 etiketleriyle birlikte g\u00f6nderilir. Bu dayan\u0131kl\u0131 etiketler, \u00e7al\u0131\u015fanlar\u0131 potansiyel ark parlamas\u0131 ve \u015fok tehlikelerine kar\u015f\u0131 uyar\u0131r.<\/p>\n<p><strong>2. Ekipman \u00f6zellikleri<\/strong><br \/>\nA\u015fa\u011f\u0131dakiler dahil eksiksiz teknik dok\u00fcmantasyon:<\/p>\n<ul>\n<li>Bara ak\u0131m ta\u015f\u0131ma kapasitesi de\u011ferleri<\/li>\n<li><a href=\"https:\/\/test.viox.com\/tr\/what-is-sccr\/\">K\u0131sa devre de\u011ferleri (SCCR)<\/a><\/li>\n<li>Koruyucu cihaz \u00f6zellikleri<\/li>\n<li>Ekipman boyutlar\u0131 ve muhafaza tipi<\/li>\n<li>Ekipman d\u00fczenini g\u00f6steren tek hat \u015femas\u0131<\/li>\n<\/ul>\n<p><strong>3. Etiket montaj yerleri<\/strong><br \/>\nM\u00fc\u015fteri taraf\u0131ndan uygulanan ayr\u0131nt\u0131l\u0131 ark parlamas\u0131 etiketleri i\u00e7in tasarlanm\u0131\u015f stratejik yerle\u015fim alanlar\u0131. Bu konumlar g\u00f6r\u00fcn\u00fcrl\u00fck, dayan\u0131kl\u0131l\u0131k ve kod uyumlulu\u011fu sa\u011flar.<\/p>\n<p><strong>4. Kurulum ve bak\u0131m dok\u00fcmantasyonu<\/strong><br \/>\nSistem performans\u0131n\u0131 ve g\u00fcvenli\u011fini etkileyen uygun kurulumu y\u00f6nlendiren kapsaml\u0131 k\u0131lavuzlar.<\/p>\n<h3>Ekipman Sahiplerinin Sa\u011flamas\u0131 Gerekenler<\/h3>\n<p><strong>1. Ark parlamas\u0131 tehlike analizi<\/strong><br \/>\nEksiksiz elektrik sisteminiz i\u00e7in IEEE 1584 hesaplamalar\u0131 yapmak \u00fczere kalifiye bir elektrik m\u00fchendisi tutun. Bu analiz \u015funlar\u0131 belirler:<\/p>\n<ul>\n<li>Her konumda mevcut ar\u0131za ak\u0131m\u0131<\/li>\n<li>Olay enerjisi seviyeleri<\/li>\n<li>Ark parlamas\u0131 s\u0131n\u0131rlar\u0131<\/li>\n<li>Gerekli KKD kategorileri<\/li>\n<\/ul>\n<p><strong>2. Sahaya \u00f6zg\u00fc ark parlamas\u0131 etiketleri<\/strong><br \/>\nM\u00fchendislik \u00e7al\u0131\u015fmas\u0131na dayanarak, hesaplanan tehlike seviyelerini g\u00f6steren ekipmana dayan\u0131kl\u0131 etiketler uygulay\u0131n. Bu etiketler NFPA 70E 130.5(H) ile uyumlu olmal\u0131d\u0131r.<\/p>\n<p><strong>3. \u00c7al\u0131\u015fan e\u011fitimi<\/strong><br \/>\nElektrik \u00e7al\u0131\u015fanlar\u0131n\u0131n ark parlamas\u0131 tehlikelerini anlad\u0131\u011f\u0131ndan, etiketleri yorumlayabildi\u011finden ve olay enerjisi veya KKD kategori bilgilerine g\u00f6re uygun KKD'yi nas\u0131l se\u00e7eceklerini bildi\u011finden emin olun.<\/p>\n<p><strong>4. Etiket g\u00fcncellemeleri<\/strong><br \/>\nArk parlamas\u0131 etiketlerini her be\u015f y\u0131lda bir veya ar\u0131za ak\u0131m\u0131n\u0131 veya koruyucu cihaz ayarlar\u0131n\u0131 etkileyebilecek elektrik sistemi de\u011fi\u015fiklikleri meydana geldi\u011finde inceleyin ve g\u00fcncelleyin.<\/p>\n<figure style=\"text-align: center; margin: 20px 0;\"><img decoding=\"async\" style=\"max-width: 100%; height: auto;\" src=\"https:\/\/img.viox.com\/Process-flowchart-showing-division-of-arc-flash-labeling-responsibilities-between-VIOX-Electric-and-equipment-owners.webp\" alt=\"Process flowchart showing division of arc flash labeling responsibilities between VIOX Electric and equipment owners\" \/><figcaption style=\"font-style: italic; color: #555; margin-top: 8px;\">VIOX Electric ve ekipman sahipleri aras\u0131ndaki ark parlamas\u0131 etiketleme sorumluluklar\u0131n\u0131n b\u00f6l\u00fcm\u00fcn\u00fc g\u00f6steren s\u00fcre\u00e7 ak\u0131\u015f \u015femas\u0131<\/figcaption><\/figure>\n<h2>VIOX M\u00fc\u015fterileri i\u00e7in Pratik Rehberlik<\/h2>\n<h3>Ad\u0131m 1: Ekipman\u0131 Genel Etiketlerle Kabul Edin<\/h3>\n<p>VIOX ekipman\u0131n\u0131z genel uyar\u0131 etiketleriyle birlikte geldi\u011finde, bunlar\u0131n mevcut ve okunakl\u0131 oldu\u011funu do\u011frulay\u0131n. Bu, VIOX'un sa\u011flad\u0131\u011f\u0131 temel NEC uyumlulu\u011fudur.<\/p>\n<h3>Ad\u0131m 2: Elektrik Sisteminizi Devreye Al\u0131n<\/h3>\n<p>T\u00fcm kurulum \u00e7al\u0131\u015fmalar\u0131n\u0131 tamamlay\u0131n, sisteme enerji verin ve koruyucu cihaz ayarlar\u0131n\u0131n tasar\u0131m \u00f6zellikleriyle e\u015fle\u015fti\u011fini do\u011frulay\u0131n.<\/p>\n<h3>Ad\u0131m 3: Bir Ark Parlamas\u0131 \u00c7al\u0131\u015fmas\u0131 S\u00f6zle\u015fmesi Yap\u0131n<\/h3>\n<p>A\u015fa\u011f\u0131dakiler i\u00e7in kalifiye bir elektrik m\u00fchendisi (ark parlamas\u0131 uzmanl\u0131\u011f\u0131na sahip P.E.) ile anla\u015f\u0131n:<\/p>\n<ul>\n<li>Eksiksiz elektrik sisteminizi modelleyin<\/li>\n<li>Her ekipman konumunda olay enerjisini hesaplay\u0131n<\/li>\n<li>Ark parlamas\u0131 s\u0131n\u0131rlar\u0131n\u0131 belirleyin<\/li>\n<li>KKD gereksinimlerini belirtin<\/li>\n<\/ul>\n<h3>Ad\u0131m 4: Sahaya \u00d6zg\u00fc Etiketler Uygulay\u0131n<\/h3>\n<p>NEC 110.21(B) gereksinimlerini kar\u015f\u0131layan dayan\u0131kl\u0131, end\u00fcstriyel s\u0131n\u0131f\u0131 etiketler kullan\u0131n. Etiketler, ekipman\u0131n \u00e7al\u0131\u015fma ortam\u0131na (s\u0131cakl\u0131k, nem, UV \u0131\u015f\u0131nlar\u0131na maruz kalma, temizlik kimyasallar\u0131) dayanmal\u0131d\u0131r.<\/p>\n<h3>Ad\u0131m 5: \u0130\u015f G\u00fcc\u00fcn\u00fcz\u00fc E\u011fitin<\/h3>\n<p>\u00c7al\u0131\u015fanlar\u0131n ark parlamas\u0131 etiketlerini yorumlayabildi\u011finden ve KKD kategorilerine veya olay enerjisi derecelendirmelerine g\u00f6re uygun KKD'yi nas\u0131l se\u00e7eceklerini anlad\u0131\u011f\u0131ndan emin olun.<\/p>\n<h3>Ad\u0131m 6: Etiket Do\u011frulu\u011funu Koruyun<\/h3>\n<p>Etiketleri \u015fu durumlarda g\u00fcncelleyin:<\/p>\n<ul>\n<li>Elektrik sistemi de\u011fi\u015fiklikleri meydana geldi\u011finde<\/li>\n<li>Ekipman eklendi\u011finde veya de\u011fi\u015ftirildi\u011finde<\/li>\n<li>Koruyucu cihaz ayarlar\u0131 de\u011fi\u015fti\u011finde<\/li>\n<li>Son g\u00fcncellemeden bu yana be\u015f y\u0131l ge\u00e7ti\u011finde<\/li>\n<\/ul>\n<h2>VIOX Ark Parlamas\u0131 Uyumlulu\u011funuzu Nas\u0131l Destekler?<\/h2>\n<p>VIOX ayr\u0131nt\u0131l\u0131 ark parlamas\u0131 hesaplamalar\u0131 sa\u011flayamasa da, uyumlulu\u011funuzu kolayla\u015ft\u0131ran katma de\u011ferli hizmetler sunuyoruz:<\/p>\n<h3>\u00d6nceden Uygulanm\u0131\u015f Etiket Montaj B\u00f6lgeleri<\/h3>\n<p>VIOX ekipman\u0131, m\u00fc\u015fteri taraf\u0131ndan uygulanan ark parlamas\u0131 etiketleri i\u00e7in ayr\u0131lm\u0131\u015f alanlar i\u00e7erir. Bu konumlar \u015funlar\u0131 sa\u011flar:<\/p>\n<ul>\n<li>Ekipmana eri\u015fen \u00e7al\u0131\u015fanlar i\u00e7in g\u00f6r\u00fcn\u00fcrl\u00fck<\/li>\n<li>Normal \u00e7al\u0131\u015fma s\u0131ras\u0131nda hasardan korunma<\/li>\n<li>OSHA ve NFPA 70E yerle\u015fim y\u00f6nergelerine uygunluk<\/li>\n<\/ul>\n<h3>Eksiksiz Teknik Dok\u00fcmantasyon<\/h3>\n<p>Her VIOX \u00fcr\u00fcn\u00fc, do\u011fru ark parlamas\u0131 \u00e7al\u0131\u015fmalar\u0131 i\u00e7in gereken \u00f6zelliklerle birlikte g\u00f6nderilir:<\/p>\n<ul>\n<li>Ekipman k\u0131sa devre de\u011ferleri<\/li>\n<li>Bara ve iletken konfig\u00fcrasyonlar\u0131<\/li>\n<li>Muhafaza boyutlar\u0131<\/li>\n<li>Koruyucu cihaz koordinasyon verileri<\/li>\n<\/ul>\n<h3>M\u00fchendislik Deste\u011fi<\/h3>\n<p>VIOX teknik destek, m\u00fchendislerin ark parlamas\u0131 hesaplamalar\u0131 i\u00e7in ihtiya\u00e7 duydu\u011fu ekipman \u00f6zellikleri hakk\u0131ndaki sorular\u0131 yan\u0131tlayabilir. Ekipman yetenekleri ve saha gereksinimleri aras\u0131ndaki bo\u015flu\u011fu dolduruyoruz.<\/p>\n<h3>\u0130ste\u011fe Ba\u011fl\u0131 Etiket Kitleri<\/h3>\n<p>VIOX, a\u015fa\u011f\u0131dakileri i\u00e7eren aksesuar kitleri sunar:<\/p>\n<ul>\n<li>NEC 110.21(B)'yi kar\u015f\u0131layan bo\u015f, dayan\u0131kl\u0131 etiket sto\u011fu<\/li>\n<li>Gerekli veri alanlar\u0131n\u0131 g\u00f6steren etiket \u015fablonlar\u0131<\/li>\n<li>Montaj talimatlar\u0131<\/li>\n<li>Koruyucu laminat kaplamalar<\/li>\n<\/ul>\n<p>Bu profesyonel s\u0131n\u0131f malzemeler, sahaya \u00f6zel etiketlerinizin VIOX ekipman kalite standartlar\u0131na uymas\u0131n\u0131 sa\u011flar.<\/p>\n<h2>S\u0131k\u00e7a Sorulan Sorular<\/h2>\n<p><strong>S: VIOX, tipik kurulumlara g\u00f6re \u201ctahmini\u201d ark parlamas\u0131 verileri sa\u011flayabilir mi?<\/strong><\/p>\n<p>C: Hay\u0131r. Sahaya \u00f6zel analiz olmadan tahmini ark parlamas\u0131 verileri sa\u011flamak, temel g\u00fcvenlik ilkelerini ihlal eder ve \u00e7al\u0131\u015fanlar\u0131 yetersiz korumaya maruz b\u0131rakabilir. Ark parlamas\u0131 olay enerjisi, benzersiz elektrik sistemi konfig\u00fcrasyonunuza g\u00f6re \u00f6nemli \u00f6l\u00e7\u00fcde de\u011fi\u015fir. Genel tahminler tehlikelidir ve NFPA 70E ile uyumlu de\u011fildir; bu, ger\u00e7ek sistem ko\u015fullar\u0131na g\u00f6re hesaplamalar gerektirir.<\/p>\n<p><strong>S: Bir ark parlamas\u0131 \u00e7al\u0131\u015fmas\u0131 tipik olarak ne kadar tutar?<\/strong><\/p>\n<p>C: Ark parlamas\u0131 \u00e7al\u0131\u015fmalar\u0131, tesisin b\u00fcy\u00fckl\u00fc\u011f\u00fcne ve karma\u015f\u0131kl\u0131\u011f\u0131na ba\u011fl\u0131 olarak tipik olarak 3.000 ila 15.000+ ABD Dolar\u0131 aras\u0131nda de\u011fi\u015fir. Maliyeti etkileyen fakt\u00f6rler \u015funlard\u0131r: analiz gerektiren ekipman konumlar\u0131n\u0131n say\u0131s\u0131, elektrik sistemi karma\u015f\u0131kl\u0131\u011f\u0131, mevcut belgelerin (tek hat \u015femalar\u0131, koruyucu cihaz ayarlar\u0131) kullan\u0131labilirli\u011fi ve k\u0131sa devre \u00e7al\u0131\u015fmalar\u0131n\u0131n zaten mevcut olup olmad\u0131\u011f\u0131. Bu yat\u0131r\u0131m \u00e7al\u0131\u015fanlar\u0131 korur ve OSHA uyumlulu\u011funu g\u00f6sterir.<\/p>\n<p><strong>S: Ayr\u0131nt\u0131l\u0131 ark parlamas\u0131 etiketleri olmadan ekipman\u0131 \u00e7al\u0131\u015ft\u0131r\u0131rsak ne olur?<\/strong><\/p>\n<p>C: Uygun ark parlamas\u0131 etiketleri olmadan \u00e7al\u0131\u015ft\u0131rmak NFPA 70E gereksinimlerini ihlal eder ve \u00e7al\u0131\u015fanlar\u0131 bilinmeyen tehlikelere maruz b\u0131rak\u0131r. OSHA, \u00e7al\u0131\u015fanlara yeterli tehlike bilgisi sa\u011flamad\u0131\u011f\u0131 i\u00e7in tesislere ceza verebilir. Daha da \u00f6nemlisi, \u00e7al\u0131\u015fanlar olay enerjisi veya KKD kategori verileri olmadan uygun KKD'yi se\u00e7emezler, bu da ciddi yaralanma riski olu\u015fturur. Bir ark parlamas\u0131 olay\u0131nda, uygun etiketlemenin olmamas\u0131 d\u00fczenleyici cezalara ve yasal sorumlulu\u011fa yol a\u00e7abilir.<\/p>\n<p><strong>S: Ayr\u0131nt\u0131l\u0131 hesaplamalar yerine NFPA 70E tablo y\u00f6ntemlerini kullanabilir miyiz?<\/strong><\/p>\n<p>C: NFPA 70E Tablo 130.7(C)(15), tan\u0131mlanm\u0131\u015f parametreleri kar\u015f\u0131layan belirli g\u00f6revler ve ekipman konfig\u00fcrasyonlar\u0131 i\u00e7in basitle\u015ftirilmi\u015f KKD se\u00e7imine izin verir. Ancak, bu y\u00f6ntemin kat\u0131 s\u0131n\u0131rlamalar\u0131 vard\u0131r ve ger\u00e7ek tehlikeleri oldu\u011fundan fazla veya az tahmin edebilir. \u00c7o\u011fu tesis, do\u011fru, ekipmana \u00f6zel veriler sa\u011flayan IEEE 1584 metodolojisini kullanarak tasarlanm\u0131\u015f olay enerjisi analizinden yararlan\u0131r. Tablo y\u00f6ntemi yaln\u0131zca kalifiye personel t\u00fcm tablo parametrelerinin ger\u00e7ek ko\u015fullarla e\u015fle\u015fti\u011fini do\u011frulad\u0131\u011f\u0131nda kullan\u0131lmal\u0131d\u0131r.<\/p>\n<p><strong>S: Ark parlamas\u0131 etiketleri ne s\u0131kl\u0131kla g\u00fcncellenmelidir?<\/strong><\/p>\n<p>C: NFPA 70E, ark parlamas\u0131 etiketlerinin do\u011frulu\u011funun be\u015f y\u0131l\u0131 a\u015fmayan aral\u0131klarla g\u00f6zden ge\u00e7irilmesini gerektirir. Ancak, ekipman ekleme veya \u00e7\u0131karma, koruyucu cihaz ayarlar\u0131n\u0131 de\u011fi\u015ftirme, \u015febeke hizmetini de\u011fi\u015ftirme, iletken uzunluklar\u0131n\u0131 veya boyutlar\u0131n\u0131 de\u011fi\u015ftirme veya transformat\u00f6rleri de\u011fi\u015ftirme dahil olmak \u00fczere olay enerjisi hesaplamalar\u0131n\u0131 etkileyebilecek elektrik sistemi de\u011fi\u015fiklikleri meydana geldi\u011finde g\u00fcncellemeler zorunludur. Sistem de\u011fi\u015fiklikleri tipik olarak be\u015f y\u0131ll\u0131k d\u00f6ng\u00fcy\u00fc beklemeden an\u0131nda etiket g\u00fcncellemelerini tetikler.<\/p>\n<p><strong>S: Ekipmanda ark parlamas\u0131 etiketi yoksa hangi KKD gereklidir?<\/strong><\/p>\n<p>C: Belirli ark parlamas\u0131 verileri olmadan, \u00e7al\u0131\u015fanlar en k\u00f6t\u00fc durumdaki tehlikeleri varsaymal\u0131 ve mevcut maksimum korumay\u0131 giymeli veya enerjili ekipman \u00fczerinde \u00e7al\u0131\u015fmaktan tamamen ka\u00e7\u0131nmal\u0131d\u0131r. NFPA 70E, i\u015fverenlerin \u00e7al\u0131\u015fanlar\u0131n enerjili ekipman \u00fczerinde veya yak\u0131n\u0131nda g\u00f6revler yapmadan \u00f6nce tehlike bilgilerine sahip olmas\u0131n\u0131 sa\u011flamas\u0131n\u0131 gerektirir. Etiketler eksikse, ger\u00e7ek tehlike seviyeleri uygun ark parlamas\u0131 analizi ile belirlenene kadar \u00e7al\u0131\u015fma durdurulmal\u0131d\u0131r. Bu, \u00e7al\u0131\u015fanlar\u0131 korur ve d\u00fczenleyici uyumlulu\u011fu sa\u011flar.<\/p>\n<p><strong>S: VIOX ekipman\u0131 ark parlamas\u0131 g\u00fcvenlik standartlar\u0131n\u0131 kar\u015f\u0131l\u0131yor mu?<\/strong><\/p>\n<p>C: VIOX ekipman\u0131, ge\u00e7erli k\u0131sa devre ak\u0131m\u0131 de\u011ferlerini (SCCR) kar\u015f\u0131layacak \u015fekilde tasarlanm\u0131\u015f ve test edilmi\u015ftir ve uygun koruyucu cihazlar i\u00e7erir. Ancak, \u201cark parlamas\u0131 g\u00fcvenli\u011fi\u201d, ekipman\u0131n belirli elektrik sisteminizde nas\u0131l uyguland\u0131\u011f\u0131na ba\u011fl\u0131d\u0131r. VIOX, uygun de\u011ferlere ve genel uyar\u0131lara sahip ekipman sa\u011flar. \u0130\u015fyeri ark parlamas\u0131 g\u00fcvenli\u011fini sa\u011flamak, sahiplerin sahaya \u00f6zel analiz yapmas\u0131n\u0131, ayr\u0131nt\u0131l\u0131 etiketler uygulamas\u0131n\u0131, \u00e7al\u0131\u015fanlar\u0131 e\u011fitmesini ve uygun KKD sa\u011flamas\u0131n\u0131 gerektirir; bunlar, NFPA 70E standartlar\u0131na g\u00f6re ekipman sahibine d\u00fc\u015fen sorumluluklard\u0131r.<\/p>\n<h2>Sonu\u00e7: G\u00fcvenlik Uyumlulu\u011funda Ortakl\u0131k<\/h2>\n<p>Ark parlamas\u0131 etiketlemesi, ekipman \u00fcreticileri ve sahipleri aras\u0131nda payla\u015f\u0131lan bir sorumlulu\u011fu temsil eder. VIOX, \u00e7al\u0131\u015fanlar\u0131 potansiyel tehlikelere kar\u015f\u0131 uyaran genel uyar\u0131 etiketlerine sahip, koda uygun ekipman sunar ve NEC 110.16 kapsam\u0131ndaki \u00fcretim y\u00fck\u00fcml\u00fcl\u00fcklerimizi yerine getirir.<\/p>\n<p>NFPA 70E taraf\u0131ndan gerekli k\u0131l\u0131nan ayr\u0131nt\u0131l\u0131 ark parlamas\u0131 analizi ve etiketleme, ekipman sahiplerine d\u00fc\u015fer, \u00e7\u00fcnk\u00fc bu hesaplamalar tamamen ekipman kurulana ve enerjilendirilene kadar var olmayan sahaya \u00f6zel elektrik sistemi \u00f6zelliklerine ba\u011fl\u0131d\u0131r. Bu sorumluluk b\u00f6l\u00fcm\u00fc b\u00fcrokratik bir engel de\u011fildir; elektrik sistemlerinin temel fizi\u011fini yans\u0131t\u0131r ve \u00e7al\u0131\u015fanlar\u0131n do\u011fru, eyleme ge\u00e7irilebilir g\u00fcvenlik bilgileri almas\u0131n\u0131 sa\u011flar.<\/p>\n<p>VIOX, kapsaml\u0131 teknik dok\u00fcmantasyon, g\u00fcvenli bak\u0131m eri\u015fimi i\u00e7in tasarlanm\u0131\u015f ekipman, \u00f6zel etiket montaj yerleri ve m\u00fchendislik deste\u011fi sa\u011flayarak m\u00fc\u015fterileriyle ortakl\u0131k kurar. Ark parlamas\u0131 uyumlulu\u011funun karma\u015f\u0131k hesaplamalar ve \u00f6nemli planlama i\u00e7erdi\u011fini anl\u0131yoruz. Taahh\u00fcd\u00fcm\u00fcz, kaliteli elektrikli ekipman sa\u011flaman\u0131n \u00f6tesine ge\u00e7erek tesisinizin eksiksiz g\u00fcvenlik program\u0131n\u0131 desteklemeye kadar uzan\u0131r.<\/p>\n<p>VIOX ekipman\u0131n\u0131 se\u00e7ti\u011finizde, ark parlamas\u0131 g\u00fcvenli\u011finin n\u00fcanslar\u0131n\u0131 anlayan, uygun etiketleme sorumlulu\u011funun s\u0131n\u0131rlar\u0131na sayg\u0131 duyan ve ba\u015far\u0131l\u0131 NFPA 70E uyumluluk program\u0131n\u0131z i\u00e7in teknik temel sa\u011flayan bir \u00fcretici se\u00e7mi\u015f olursunuz.<\/p>\n<p><strong>Bir sonraki elektrikli ekipman projenizi g\u00f6r\u00fc\u015fmeye haz\u0131r m\u0131s\u0131n\u0131z?<\/strong> <a href=\"http:\/\/voix.com\/contact\" rel=\"nofollow noopener\" target=\"_blank\">Tesisinizin ark parlamas\u0131 g\u00fcvenli\u011fi gereksinimlerini \u00fcr\u00fcnlerimizin nas\u0131l destekledi\u011fini \u00f6\u011frenmek i\u00e7in VIOX Electric'in<\/a> teknik sat\u0131\u015f ekibiyle ileti\u015fime ge\u00e7in.<\/p>\n<\/div>\n<div class=\"simg-pop-btn\" style=\"top: 3425.36px; left: 14px; display: none;\"><\/div>\n<div class=\"simg-pop-btn\" style=\"top: 3425.36px; left: 14px; display: none;\"><\/div>\n<div class=\"simg-pop-btn\" style=\"top: 3445.86px; left: 14px; display: none;\"><\/div>\n<div class=\"simg-pop-btn\" style=\"top: 3445.86px; left: 14px; display: none;\"><\/div>\n<div class=\"simg-pop-btn\" style=\"top: 1676.95px; left: 14px; display: none;\"><\/div>\n<div class=\"simg-pop-btn\" style=\"top: 1676.95px; left: 14px; display: none;\"><\/div>\n<div class=\"simg-pop-btn\" style=\"top: 319.828px; left: 14px; display: none;\"><\/div>\n<div class=\"simg-pop-btn\" style=\"top: 319.828px; left: 14px; display: none;\"><\/div>","protected":false},"excerpt":{"rendered":"<p>Why Your New VIOX Equipment Arrives With a Generic Warning Label (And Why That&#8217;s Actually Correct) When you unpack a new VIOX switchgear or panelboard, you might notice a bright yellow warning label that reads &#8220;Danger &#8211; Arc Flash and Shock Hazard.&#8221; Some customers ask: &#8220;Where&#8217;s the specific incident energy data? What PPE category should [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":21131,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1],"tags":[],"class_list":["post-21129","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"_links":{"self":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/posts\/21129","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/comments?post=21129"}],"version-history":[{"count":3,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/posts\/21129\/revisions"}],"predecessor-version":[{"id":21137,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/posts\/21129\/revisions\/21137"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/media\/21131"}],"wp:attachment":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/media?parent=21129"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/categories?post=21129"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/tags?post=21129"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}