{"id":20767,"date":"2025-12-12T22:46:46","date_gmt":"2025-12-12T14:46:46","guid":{"rendered":"https:\/\/viox.com\/?p=20767"},"modified":"2025-12-12T22:47:46","modified_gmt":"2025-12-12T14:47:46","slug":"semaphore-indicator-vs-stack-light-guide","status":"publish","type":"post","link":"https:\/\/test.viox.com\/tr\/semaphore-indicator-vs-stack-light-guide\/","title":{"rendered":"Semaf\u00f6r G\u00f6stergesi mi Yoksa Sinyal Lambas\u0131 m\u0131: Hangi Sinyal Cihaz\u0131na \u0130htiyac\u0131n\u0131z Var?"},"content":{"rendered":"<div class=\"product-intro\">\n<p>End\u00fcstriyel otomasyonun y\u00fcksek riskli ortam\u0131nda, ka\u00e7\u0131r\u0131lan bir sinyal \u00fcretim kayb\u0131, ekipman hasar\u0131 veya g\u00fcvenlik tehlikeleri anlam\u0131na gelebilir. G\u00f6rsel sinyal cihazlar\u0131, fabrika zemininin birincil dilidir ve makine durumunu operat\u00f6rlere ve m\u00fchendislere an\u0131nda iletir. Ancak mevcut \u00e7e\u015fitli se\u00e7eneklerle, do\u011fru cihaz\u0131 se\u00e7mek kritik \u00f6neme sahiptir.<\/p>\n<p>En yayg\u0131n g\u00f6rsel sinyal cihazlar\u0131ndan ikisi \u015funlard\u0131r: <strong>semafor g\u00f6stergesinin<\/strong> ve <strong>sinyal kulesi<\/strong> (sinyal kulesi olarak da bilinir). Her ikisi de bilgi iletmek i\u00e7in \u0131\u015f\u0131k kullan\u0131rken, temelde farkl\u0131 ama\u00e7lara hizmet eder, farkl\u0131 alanlar\u0131 kaplar ve farkl\u0131 kitlelere ileti\u015fim kurar.<\/p>\n<p>Bu k\u0131lavuz, semafor g\u00f6stergeleri ile sinyal kuleleri aras\u0131ndaki teknik farkl\u0131l\u0131klar\u0131, uygulama senaryolar\u0131n\u0131 ve se\u00e7im kriterlerini ayr\u0131nt\u0131l\u0131 olarak a\u00e7\u0131klayarak, kontrol paneliniz veya makineniz i\u00e7in do\u011fru bile\u015feni belirtmenize yard\u0131mc\u0131 olur.<\/p>\n<figure style=\"margin: 20px 0; text-align: center;\"><img decoding=\"async\" style=\"max-width: 100%; height: auto;\" src=\"https:\/\/img.viox.com\/side-by-side-comparison-of-viox-semaphore-indicator-left-and-viox-stack-light-tower-right-highlighting-size-and-mounting-differences.webp\" alt=\"Side-by-side comparison of VIOX semaphore indicator and VIOX stack light tower\" \/><figcaption style=\"font-style: italic; font-size: 0.9em; color: #666; margin-top: 8px;\">VIOX semafor g\u00f6stergesinin (solda) ve VIOX sinyal kulesinin (sa\u011fda) yan yana kar\u015f\u0131la\u015ft\u0131rmas\u0131, boyut ve montaj farkl\u0131l\u0131klar\u0131n\u0131 vurgulamaktad\u0131r.<\/figcaption><\/figure>\n<h2>Tan\u0131mlar ve Temel \u0130\u015flevler<\/h2>\n<h3>Semafor G\u00f6stergesi Nedir?<\/h3>\n<p>A <a href=\"https:\/\/test.viox.com\/tr\/switch-position-indicator\/\"><strong>semafor g\u00f6stergesinin<\/strong><\/a> tipik olarak bir <a href=\"https:\/\/test.viox.com\/tr\/mcb\/\">devre kesici<\/a>, <a href=\"https:\/\/test.viox.com\/tr\/what-is-the-difference-between-a-circuit-breaker-and-a-disconnector\/\">ay\u0131r\u0131c\u0131<\/a>, veya valfin belirli durumunu g\u00f6stermek i\u00e7in tasarlanm\u0131\u015f, kompakt, panele monte edilmi\u015f bir cihazd\u0131r. Genellikle do\u011frudan kontrol paneli kapa\u011f\u0131na veya bir taklit diyagram\u0131 i\u00e7ine monte edilir.<\/p>\n<ul>\n<li><strong>Birincil \u0130\u015flev:<\/strong> Konum g\u00f6stergesi (A\u00e7\u0131k\/Kapal\u0131, A\u00e7\u0131k\/Kapal\u0131, G\u00fcvenli\/Tehlikeli).<\/li>\n<li><strong>Hedef Kitle:<\/strong> Do\u011frudan kontrol panelinin \u00f6n\u00fcnde duran operat\u00f6r veya m\u00fchendis.<\/li>\n<li><strong>Form Fakt\u00f6r\u00fc:<\/strong> Genellikle g\u00f6mme montajl\u0131, tekli 22 mm veya 30 mm yuvarlak \u00fcnite.<\/li>\n<li><strong>G\u00f6rsel \u00c7\u0131kt\u0131:<\/strong> \u00c7ift renkli LED (K\u0131rm\u0131z\u0131\/Ye\u015fil) veya farkl\u0131 semboller (\u00c7ubuk\/Daire).<\/li>\n<\/ul>\n<h3>Sinyal Kulesi (Sinyal Kulesi) Nedir?<\/h3>\n<p>A <strong>sinyal kulesi<\/strong> makinelerin veya kontrol kabinlerinin \u00fczerine monte edilmi\u015f, s\u00fctunlu, \u00e7ok segmentli bir sinyal cihaz\u0131d\u0131r. Bir makinenin veya i\u015flem hatt\u0131n\u0131n genel \u00e7al\u0131\u015fma durumunu \u00e7evreye yay\u0131nlamak i\u00e7in renk kodlu katmanlar kullan\u0131r.<\/p>\n<ul>\n<li><strong>Birincil \u0130\u015flev:<\/strong> Makine durumu yay\u0131n\u0131 (\u00c7al\u0131\u015f\u0131yor, Durdu, Malzeme Az, Ar\u0131za).<\/li>\n<li><strong>Hedef Kitle:<\/strong> Fabrika personeli, forklift s\u00fcr\u00fcc\u00fcleri ve makineden uzakta bulunan denet\u00e7iler.<\/li>\n<li><strong>Form Fakt\u00f6r\u00fc:<\/strong> Dikey s\u00fctun (40 mm-100 mm \u00e7ap), dire\u011fe monte veya do\u011frudan monte.<\/li>\n<li><strong>G\u00f6rsel \u00c7\u0131kt\u0131:<\/strong> Genellikle 360\u00b0 g\u00f6r\u00fcn\u00fcrl\u00fc\u011fe sahip 3-5 istiflenmi\u015f renk (K\u0131rm\u0131z\u0131, Sar\u0131, Ye\u015fil, Mavi, Beyaz).<\/li>\n<\/ul>\n<h2>Temel Teknik Farkl\u0131l\u0131klar<\/h2>\n<table style=\"width: 100%; border-collapse: collapse; margin: 20px 0;\" border=\"1\">\n<thead>\n<tr style=\"background-color: #f9f9f9;\">\n<th style=\"padding: 12px; text-align: left;\">\u00d6zellik<\/th>\n<th style=\"padding: 12px; text-align: left;\">Semafor G\u00f6stergesi<\/th>\n<th style=\"padding: 12px; text-align: left;\">Sinyal Kulesi (Sinyal Kulesi)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"padding: 12px;\"><strong>G\u00f6r\u00fcn\u00fcrl\u00fck Aral\u0131\u011f\u0131<\/strong><\/td>\n<td style=\"padding: 12px;\">K\u0131sa menzil (0,5 \u2013 2 metre). \u201cYak\u0131n alan\u201d okuma i\u00e7in tasarlanm\u0131\u015ft\u0131r.<\/td>\n<td style=\"padding: 12px;\">Uzun menzil (10 \u2013 50+ metre). \u201cUzak alan\u201d yay\u0131n\u0131 i\u00e7in tasarlanm\u0131\u015ft\u0131r.<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 12px;\"><strong>Bilgi Yo\u011funlu\u011fu<\/strong><\/td>\n<td style=\"padding: 12px;\">Belirli bir bile\u015fenin ikili durumu (A - B).<\/td>\n<td style=\"padding: 12px;\">\u00c7ok durumlu sistem durumu (3-5 farkl\u0131 durum).<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 12px;\"><strong>Montaj Yeri<\/strong><\/td>\n<td style=\"padding: 12px;\">Kontrol paneli y\u00fcz\u00fc, taklit diyagram\u0131, konsol.<\/td>\n<td style=\"padding: 12px;\">Makine \u00fcst\u00fc, elektrik panosu \u00e7at\u0131s\u0131, duvar braketi.<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 12px;\"><strong>Kablolama Karma\u015f\u0131kl\u0131\u011f\u0131<\/strong><\/td>\n<td style=\"padding: 12px;\">Yard\u0131mc\u0131 kontaklara do\u011frudan kablolama (basit).<\/td>\n<td style=\"padding: 12px;\">PLC \u00e7\u0131k\u0131\u015flar\u0131na \u00e7oklu kablo veya tek kablo IO-Link (karma\u015f\u0131k).<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 12px;\"><strong>Sesli Alarm<\/strong><\/td>\n<td style=\"padding: 12px;\">Nadiren entegre (gerekirse ayr\u0131 buzzer kullan\u0131l\u0131r).<\/td>\n<td style=\"padding: 12px;\">S\u0131k s\u0131k entegre (85-100dB buzzer\/siren).<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<figure style=\"margin: 20px 0; text-align: center;\"><img decoding=\"async\" style=\"max-width: 100%; height: auto;\" src=\"https:\/\/img.viox.com\/viox-semaphore-indicator-mounted-on-control-panel-mimic-diagram-showing-tri-state-led-pattern-with-red-and-green-bars-indicating-circuit-breaker-position.webp\" alt=\"VIOX semaphore indicator mounted on control panel mimic diagram\" \/><figcaption style=\"font-style: italic; font-size: 0.9em; color: #666; margin-top: 8px;\">Devre kesici konumunu g\u00f6steren k\u0131rm\u0131z\u0131 ve ye\u015fil \u00e7ubuklarla \u00fc\u00e7 durumlu LED desenini g\u00f6steren kontrol paneli taklit diyagram\u0131na monte edilmi\u015f VIOX semafor g\u00f6stergesi<\/figcaption><\/figure>\n<h2>Uygulama Senaryolar\u0131: Hangisi Ne Zaman Kullan\u0131l\u0131r?<\/h2>\n<h3>Senaryo A: \u015ealt Odas\u0131<\/h3>\n<p><strong>Gereklilik:<\/strong> Bir m\u00fchendisin, bak\u0131m yapmadan \u00f6nce Ana Besleme Devre Kesici 3'\u00fcn a\u00e7\u0131k olup olmad\u0131\u011f\u0131n\u0131 do\u011frulamas\u0131 gerekiyor.<\/p>\n<p><strong>Se\u00e7im:<\/strong> <strong>Semafor G\u00f6stergesi.<\/strong><\/p>\n<p><strong>Neden?<\/strong> M\u00fchendis panelin \u00f6n\u00fcnde duruyor. Belirli bir bile\u015fenin mekanik durumunun kesin olarak teyit edilmesi gerekiyor. Kabinin \u00fczerindeki bir sinyal kulesi yaln\u0131zca t\u00fcm kart i\u00e7in genel \u201cAr\u0131za\u201d veya \u201cSa\u011fl\u0131kl\u0131\u201d durumunu g\u00f6sterir ki bu, g\u00fcvenli anahtarlama i\u015flemleri i\u00e7in yetersizdir. Semafor g\u00f6stergesi, kesicinin yard\u0131mc\u0131 kontaklar\u0131ndan kesin, do\u011frudan geri bildirim sa\u011flar.<\/p>\n<h3>Senaryo B: Otomotiv Montaj Hatt\u0131<\/h3>\n<p><strong>Gereklilik:<\/strong> Bir CNC makinesinin hammaddesi bitmi\u015f ve durmu\u015f. Alan amirinin bir teknisyen g\u00f6revlendirmek i\u00e7in derhal bilmesi gerekiyor.<\/p>\n<p><strong>Se\u00e7im:<\/strong> <strong>Sinyal Kulesi.<\/strong><\/p>\n<p><strong>Neden?<\/strong> S\u00fcperviz\u00f6r\u00fcn 20 metre uzakta zeminde y\u00fcr\u00fcmesi muhtemeldir. K\u00fc\u00e7\u00fck bir panel \u0131\u015f\u0131\u011f\u0131 o mesafeden g\u00f6r\u00fcnmez. Ayd\u0131nlat\u0131lm\u0131\u015f Mavi veya Sar\u0131 katmana sahip (malzeme k\u0131tl\u0131\u011f\u0131\/yard\u0131m i\u00e7in standart renkler) uzun bir sinyal kulesi, engellerin ve di\u011fer makinelerin \u00fczerinde an\u0131nda g\u00f6r\u00fcn\u00fcrl\u00fck sa\u011flayarak ar\u0131za s\u00fcresini azalt\u0131r.<\/p>\n<figure style=\"margin: 20px 0; text-align: center;\"><img decoding=\"async\" style=\"max-width: 100%; height: auto;\" src=\"https:\/\/img.viox.com\/viox-modular-stack-light-with-five-color-tiers-red-yellow-blue-green-white-mounted-on-industrial-machine-frame-in-factory-setting.webp\" alt=\"VIOX modular stack light mounted on industrial machine frame\" \/><figcaption style=\"font-style: italic; font-size: 0.9em; color: #666; margin-top: 8px;\">Fabrika ortam\u0131nda end\u00fcstriyel makine \u00e7er\u00e7evesine monte edilmi\u015f be\u015f renk katmanl\u0131 (K\u0131rm\u0131z\u0131, Sar\u0131, Mavi, Ye\u015fil, Beyaz) VIOX mod\u00fcler sinyal kulesi<\/figcaption><\/figure>\n<h3>Senaryo C: Andon Panosu Sistemi<\/h3>\n<p><strong>Gereklilik:<\/strong> Manuel montaj istasyonlar\u0131ndaki operat\u00f6rlerin, istasyonlar\u0131ndan ayr\u0131lmadan kalite kontrolleri veya par\u00e7a ikmali i\u00e7in sinyal vermeleri gerekiyor.<\/p>\n<p><strong>Se\u00e7im:<\/strong> <strong>Sinyal Kulesi (Andon I\u015f\u0131\u011f\u0131).<\/strong><\/p>\n<p><strong>Neden?<\/strong> Sinyal, mobil olan destek personeli (lojistik, kalite kontrol) taraf\u0131ndan g\u00f6r\u00fclmesi gereken bir \u201cyard\u0131m \u00e7a\u011fr\u0131s\u0131d\u0131r\u201d. Bir sinyal kulesinin 360 derecelik g\u00f6r\u00fcn\u00fcrl\u00fc\u011f\u00fc, talebin \u00fcretim kat\u0131ndaki herhangi bir a\u00e7\u0131dan g\u00f6r\u00fclmesini sa\u011flar.<\/p>\n<figure style=\"margin: 20px 0; text-align: center;\"><img decoding=\"async\" style=\"max-width: 100%; height: auto;\" src=\"https:\/\/img.viox.com\/factory-floor-scene-showing-operators-responding-to-visual-signals-from-viox-andon-stack-lights-on-manufacturing-equipment-demonstrating-area-wide-visibility.webp\" alt=\"Factory floor scene showing operators responding to visual signals from VIOX Andon stack lights\" \/><figcaption style=\"font-style: italic; font-size: 0.9em; color: #666; margin-top: 8px;\">\u00dcretim ekipman\u0131ndaki VIOX Andon sinyal kulelerinden gelen g\u00f6rsel sinyallere yan\u0131t veren operat\u00f6rleri g\u00f6steren fabrika kat\u0131 sahnesi, alan \u00e7ap\u0131nda g\u00f6r\u00fcn\u00fcrl\u00fc\u011f\u00fc g\u00f6steriyor<\/figcaption><\/figure>\n<h2>Modern Yenilikler: End\u00fcstri 4.0 Entegrasyonu<\/h2>\n<p>Semafor g\u00f6stergeleri nispeten basit, sa\u011flam cihazlar (g\u00fcvenilirlik ve LED \u00f6mr\u00fcne odaklanan) olarak kal\u0131rken, sinyal kuleleri End\u00fcstri 4.0 \u00e7a\u011f\u0131nda \u00f6nemli \u00f6l\u00e7\u00fcde geli\u015fti.<\/p>\n<p><strong>Ak\u0131ll\u0131 Sinyal Kuleleri:<\/strong> Modern VIOX sinyal kuleleri genellikle IO-Link ba\u011flant\u0131s\u0131na sahiptir. Basit kablolu A\u00e7\u0131k\/Kapal\u0131 kontrol\u00fc yerine, bu cihazlar \u015funlar\u0131 yapabilir:<\/p>\n<ul>\n<li>Sonsuz durum olas\u0131l\u0131klar\u0131 i\u00e7in \u00f6zel renkler (RGB) g\u00f6r\u00fcnt\u00fcleyin.<\/li>\n<li>Seviye g\u00f6stergesi sa\u011flay\u0131n (\u00f6rne\u011fin, \u0131\u015f\u0131k \u00e7ubu\u011fu tank seviyesi veya \u00e7evrim s\u00fcresi i\u00e7in bir ilerleme \u00e7ubu\u011fu g\u00f6revi g\u00f6r\u00fcr).<\/li>\n<li>Verileri PLC'ye geri bildirin (\u00f6rne\u011fin, \u201cI\u015f\u0131k mod\u00fcl\u00fc s\u0131cakl\u0131\u011f\u0131 y\u00fcksek\u201d veya \u201cBuzzer ar\u0131zas\u0131\u201d).<\/li>\n<\/ul>\n<figure style=\"margin: 20px 0; text-align: center;\"><img decoding=\"async\" style=\"max-width: 100%; height: auto;\" src=\"https:\/\/img.viox.com\/viox-stack-light-base-with-io-link-m12-connector-in-industrial-control-cabinet-showing-industry-4-0-integration-with-plcs-and-network-switches.webp\" alt=\"VIOX stack light base with IO-Link M12 connector\" \/><figcaption style=\"font-style: italic; font-size: 0.9em; color: #666; margin-top: 8px;\">End\u00fcstriyel kontrol kabininde IO-Link M12 konekt\u00f6rl\u00fc VIOX sinyal kulesi taban\u0131, PLC'ler ve a\u011f anahtarlar\u0131 ile End\u00fcstri 4.0 entegrasyonunu g\u00f6steriyor<\/figcaption><\/figure>\n<h2>Sonu\u00e7: Rekabet\u00e7i De\u011fil, Tamamlay\u0131c\u0131<\/h2>\n<p>Bir semafor g\u00f6stergesi ile bir sinyal lambas\u0131 aras\u0131ndaki se\u00e7im nadiren \u201cya\/ya da\u201d \u015feklindedir; genellikle \u201chem\/hem de\u201d \u015feklindedir.\u201d<\/p>\n<p>\u0130yi tasarlanm\u0131\u015f bir end\u00fcstriyel sistemde:<\/p>\n<ul>\n<li><strong>Sinyal Lambalar\u0131<\/strong> \u201cmakroskobik\u201d g\u00f6r\u00fcn\u00fcm\u00fc sa\u011flar: \u201cBu makinenin bak\u0131ma ihtiyac\u0131 var.\u201d<\/li>\n<li><strong>Semafor G\u00f6stergeleri<\/strong> \u201cmikroskobik\u201d detay\u0131 sa\u011flar: \u201cAna \u015falter att\u0131\u201d veya \u201cGiri\u015f vanas\u0131 kapal\u0131.\u201d<\/li>\n<\/ul>\n<p>M\u00fchendisler, her iki cihaz\u0131 da uygun ba\u011flamlarda kullanarak, g\u00fcvenli\u011fi, verimlili\u011fi ve yan\u0131t h\u0131z\u0131n\u0131 en \u00fcst d\u00fczeye \u00e7\u0131karan katmanl\u0131 bir bilgi sistemi olu\u015ftururlar. Kontrol paneli tasar\u0131m\u0131 i\u00e7in, bile\u015fen durumu i\u00e7in y\u00fcksek kaliteli VIOX semafor g\u00f6stergeleri ve sistem g\u00f6r\u00fcn\u00fcrl\u00fc\u011f\u00fc i\u00e7in sa\u011flam VIOX sinyal lambalar\u0131 belirtti\u011finizden emin olun.<\/p>\n<\/div>\n<div class=\"simg-pop-btn\" style=\"top: 264px; left: 14px; display: none;\"><\/div>\n<div class=\"simg-pop-btn\" style=\"top: 264px; left: 14px; display: none;\"><\/div>\n<div class=\"simg-pop-btn\" style=\"top: 1856.55px; left: 14px; display: none;\"><\/div>\n<div class=\"simg-pop-btn\" style=\"top: 1856.55px; left: 14px; display: none;\"><\/div>\n<div class=\"simg-pop-btn\" style=\"top: 2124.68px; left: 14px; display: none;\"><\/div>\n<div class=\"simg-pop-btn\" style=\"top: 1996.18px; left: 14px; display: none;\"><\/div>","protected":false},"excerpt":{"rendered":"<p>In the high-stakes environment of industrial automation, a missed signal can mean lost production, damaged equipment, or safety hazards. Visual signaling devices are the primary language of the factory floor, communicating machine status instantly to operators and engineers. But with various options available, selecting the right device is critical. Two of the most common visual [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":20769,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1],"tags":[],"class_list":["post-20767","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"_links":{"self":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/posts\/20767","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/comments?post=20767"}],"version-history":[{"count":2,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/posts\/20767\/revisions"}],"predecessor-version":[{"id":20770,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/posts\/20767\/revisions\/20770"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/media\/20769"}],"wp:attachment":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/media?parent=20767"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/categories?post=20767"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/tags?post=20767"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}