{"id":10375,"date":"2024-11-24T10:49:16","date_gmt":"2024-11-24T02:49:16","guid":{"rendered":"https:\/\/viox.com\/?p=10375"},"modified":"2024-11-24T13:42:58","modified_gmt":"2024-11-24T05:42:58","slug":"how-to-identify-cable-gland-threads","status":"publish","type":"post","link":"https:\/\/test.viox.com\/tr\/how-to-identify-cable-gland-threads\/","title":{"rendered":"Kablo Bezi Di\u015flerini Tan\u0131mlama"},"content":{"rendered":"<div class=\"product-intro\">\n<p>NPT, Metrik ve PG dahil olmak \u00fczere kablo rakoru di\u015f tipleri, elektrik tesisatlar\u0131nda her biri belirli ama\u00e7lara ve uygulamalara hizmet eden \u00e7ok \u00f6nemli bile\u015fenlerdir. Bu vida di\u015fi t\u00fcrlerinin nas\u0131l tan\u0131mlanaca\u011f\u0131n\u0131n anla\u015f\u0131lmas\u0131, \u00e7e\u015fitli end\u00fcstriyel ve ticari ortamlarda uygun uyum, s\u0131zd\u0131rmazl\u0131k ve uyumlulu\u011fun sa\u011flanmas\u0131 i\u00e7in gereklidir.<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-7292\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/cable-gland-blog-banner.webp\" alt=\"\" width=\"800\" height=\"400\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/cable-gland-blog-banner.webp 800w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/cable-gland-blog-banner-300x150.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/cable-gland-blog-banner-768x384.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/cable-gland-blog-banner-600x300.webp 600w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<p style=\"text-align: center;\"><a href=\"https:\/\/test.viox.com\/tr\/cable-gland\/\">VIOX Kablo Rakoru Konnekt\u00f6r\u00fc<\/a><\/p>\n<h2>NPT Di\u015f \u00d6zellikleri<\/h2>\n<p><img decoding=\"async\" class=\"alignnone  wp-image-10380\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/11\/NPT-thread-and-Male-NPT-thread.webp\" alt=\"\" width=\"768\" height=\"459\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/11\/NPT-thread-and-Male-NPT-thread.webp 935w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/11\/NPT-thread-and-Male-NPT-thread-300x179.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/11\/NPT-thread-and-Male-NPT-thread-768x459.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/11\/NPT-thread-and-Male-NPT-thread-18x12.webp 18w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/11\/NPT-thread-and-Male-NPT-thread-600x359.webp 600w\" sizes=\"(max-width: 768px) 100vw, 768px\" \/><\/p>\n<p style=\"text-align: center;\"><a href=\"https:\/\/inpart24.com\/en\/resources\/article\/29\/npt-thread-chart-dimensions-how-to-measure\" rel=\"nofollow noopener\" target=\"_blank\">inpart24'e kredi<\/a><\/p>\n<p>NPT (Ulusal Boru Di\u015fi), \u00f6zellikle Kuzey Amerika'da kablo rakoru uygulamalar\u0131nda yayg\u0131n olarak kullan\u0131lan bir di\u015f tipidir. Bu di\u015fler, uygun \u015fekilde s\u0131k\u0131ld\u0131\u011f\u0131nda g\u00fcvenli bir s\u0131zd\u0131rmazl\u0131k sa\u011flayan konik profilleriyle karakterize edilir. NPT di\u015flerinin konikli\u011fi, di\u015f uzunlu\u011funun her bir in\u00e7inde yakla\u015f\u0131k 1\/16 in\u00e7tir ve s\u0131zd\u0131rmazl\u0131k \u00f6zelliklerini geli\u015ftiren kama benzeri bir uyum olu\u015fturur.<\/p>\n<p>NPT di\u015fleri, borunun veya ba\u011flant\u0131 par\u00e7as\u0131n\u0131n yakla\u015f\u0131k i\u00e7 \u00e7ap\u0131n\u0131 ifade eden 1\/2\u2033 NPT veya 3\/4\u2033 NPT gibi kesirli boyut tan\u0131mlamalar\u0131yla tan\u0131mlan\u0131r. Bu boyutlar\u0131n nominal oldu\u011funu ve ger\u00e7ek di\u015f boyutlar\u0131na do\u011frudan kar\u015f\u0131l\u0131k gelmedi\u011fini unutmamak \u00f6nemlidir.<\/p>\n<p>NPT di\u015flerinin temel \u00f6zellikleri \u015funlard\u0131r:<\/p>\n<ul>\n<li>Konik profil: Di\u015fin \u00e7ap\u0131 tabandan uca do\u011fru azal\u0131r ve kar\u015f\u0131l\u0131k gelen bir di\u015fi di\u015fle e\u015fle\u015ftirildi\u011finde s\u0131k\u0131 bir s\u0131zd\u0131rmazl\u0131k sa\u011flar.<\/li>\n<li>60\u00b0 yan a\u00e7\u0131: Metrik di\u015flere benzer \u015fekilde, NPT di\u015fleri biti\u015fik di\u015flerin yanaklar\u0131 aras\u0131nda 60\u00b0 a\u00e7\u0131ya sahiptir.<\/li>\n<li>Sa\u011f vida di\u015fi y\u00f6n\u00fc: NPT di\u015fleri tipik olarak sa\u011f y\u00f6nl\u00fcd\u00fcr, yani saat y\u00f6n\u00fcnde \u00e7evrildiklerinde s\u0131k\u0131l\u0131rlar.<\/li>\n<li>Kendinden s\u0131zd\u0131rmazl\u0131k \u00f6zellikleri: Konik tasar\u0131m, NPT di\u015flerinin ek s\u0131zd\u0131rmazl\u0131k maddesi olmadan s\u0131zd\u0131rmazl\u0131k sa\u011flamas\u0131na olanak tan\u0131r, ancak s\u0131zd\u0131rmazl\u0131\u011f\u0131 art\u0131rmak ve safray\u0131 \u00f6nlemek i\u00e7in genellikle di\u015f band\u0131 veya s\u0131zd\u0131rmazl\u0131k maddesi kullan\u0131l\u0131r.<\/li>\n<\/ul>\n<p>NPT di\u015fleri, s\u0131v\u0131 ge\u00e7irmez veya gaz ge\u00e7irmez contalar gerektiren uygulamalarda yayg\u0131n olarak kullan\u0131l\u0131r, bu da onlar\u0131 \u00e7e\u015fitli end\u00fcstriyel ortamlar i\u00e7in uygun hale getirir. NPT kablo rakorlar\u0131n\u0131 se\u00e7erken, gerekli giri\u015f korumas\u0131 (IP) derecesi ve kurulumun \u00f6zel \u00e7evresel ko\u015fullar\u0131 gibi fakt\u00f6rleri g\u00f6z \u00f6n\u00fcnde bulundurmak \u00e7ok \u00f6nemlidir.<\/p>\n<p>NPT di\u015fleri m\u00fckemmel s\u0131zd\u0131rmazl\u0131k \u00f6zellikleri sunarken, metrik veya PG tipleri gibi d\u00fcz di\u015flere k\u0131yasla tak\u0131lmas\u0131 ve \u00e7\u0131kar\u0131lmas\u0131 daha zor olabilir. Bunun nedeni, dikkatle y\u00f6netilmedi\u011fi takdirde a\u015f\u0131r\u0131 s\u0131kmaya yol a\u00e7abilen konik profildir.<\/p>\n<p>NPT di\u015flerinin benzersiz \u00f6zelliklerinin anla\u015f\u0131lmas\u0131, bu di\u015f tiplerinin yayg\u0131n oldu\u011fu uygulamalarda kablo rakorlar\u0131n\u0131n do\u011fru se\u00e7imi, montaj\u0131 ve bak\u0131m\u0131 i\u00e7in gereklidir ve elektrik tesisatlar\u0131nda optimum performans ve g\u00fcvenlik sa\u011flar.<\/p>\n<h2>Metrik Di\u015f Tan\u0131mlama<\/h2>\n<p><img decoding=\"async\" class=\"alignnone wp-image-10385 size-full\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/11\/Metric-thread-1-e1732417157302.webp\" alt=\"\" width=\"935\" height=\"319\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/11\/Metric-thread-1-e1732417157302.webp 935w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/11\/Metric-thread-1-e1732417157302-300x102.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/11\/Metric-thread-1-e1732417157302-768x262.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/11\/Metric-thread-1-e1732417157302-18x6.webp 18w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/11\/Metric-thread-1-e1732417157302-600x205.webp 600w\" sizes=\"(max-width: 935px) 100vw, 935px\" \/><\/p>\n<p>Metrik di\u015fler kablo rakoru uygulamalar\u0131nda, \u00f6zellikle Avrupa ve uluslararas\u0131 pazarlarda yayg\u0131n olarak kullan\u0131lmaktad\u0131r. Bu di\u015fler d\u00fcz, silindirik profilleriyle karakterize edilir ve \"M\" \u00f6n ekinin ard\u0131ndan di\u015fin milimetre cinsinden d\u0131\u015f \u00e7ap\u0131 ile kolayca tan\u0131mlanabilir. \u00d6rne\u011fin, M20, 20 mm d\u0131\u015f \u00e7apa sahip bir metrik di\u015fi g\u00f6sterir.<\/p>\n<p>Metrik kablo rakoru di\u015fleri tipik olarak M12 ile M63 aras\u0131nda de\u011fi\u015fir ve farkl\u0131 kablo \u00e7aplar\u0131n\u0131 ve kurulum gereksinimlerini kar\u015f\u0131lamak i\u00e7in \u00e7ok \u00e7e\u015fitli boyutlar sunar. Biti\u015fik di\u015f tepeleri aras\u0131ndaki mesafe olan di\u015f aral\u0131\u011f\u0131, her boyut i\u00e7in standartla\u015ft\u0131r\u0131lm\u0131\u015ft\u0131r ve standarttan sapmad\u0131\u011f\u0131 s\u00fcrece genellikle di\u015f tan\u0131m\u0131nda a\u00e7\u0131k\u00e7a belirtilmez.<\/p>\n<p>Metrik di\u015flerin en \u00f6nemli \u00f6zelliklerinden biri, NPT di\u015flere benzeyen ancak PG di\u015flerin 80\u00b0'lik a\u00e7\u0131s\u0131ndan farkl\u0131 olan 60\u00b0'lik yan a\u00e7\u0131lar\u0131d\u0131r. Bu standartla\u015ft\u0131r\u0131lm\u0131\u015f a\u00e7\u0131, farkl\u0131 \u00fcreticiler ve uygulamalar aras\u0131nda uyumluluk sa\u011flar.<\/p>\n<p>Metrik di\u015fleri tan\u0131mlarken a\u015fa\u011f\u0131daki \u00f6zelliklere dikkat edin:<\/p>\n<ul>\n<li>D\u00fcz profil: NPT di\u015flerinin aksine, metrik di\u015fler uzunluklar\u0131 boyunca tutarl\u0131 bir \u00e7apa sahiptir.<\/li>\n<li>Boyut i\u015faretleri: \"M\" \u00f6n ekini ve ard\u0131ndan milimetre cinsinden d\u0131\u015f \u00e7ap\u0131 temsil eden bir say\u0131y\u0131 aray\u0131n.<\/li>\n<li>\u0130nce hatve se\u00e7enekleri: Baz\u0131 metrik di\u015fler, \u00f6zel uygulamalar i\u00e7in \u00e7aptan sonra bir say\u0131 ile g\u00f6sterilen daha ince bir ad\u0131ma sahip olabilir (\u00f6rne\u011fin, M20x1.5).<\/li>\n<\/ul>\n<p>Metrik di\u015fler hassas uyumlar\u0131 ve montaj kolayl\u0131klar\u0131 ile bilinir, bu da onlar\u0131 s\u0131k bak\u0131m veya ekipman de\u011fi\u015fikli\u011fi gerektiren end\u00fcstrilerde pop\u00fcler hale getirir. Ayr\u0131ca uygun contalar veya O-ringlerle birlikte kullan\u0131ld\u0131klar\u0131nda m\u00fckemmel s\u0131zd\u0131rmazl\u0131k \u00f6zellikleri sunarlar.<\/p>\n<p>Metrik di\u015f tan\u0131mlamas\u0131n\u0131n \u00f6zelliklerini anlamak, \u00f6zellikle uluslararas\u0131 standartlar veya ekipmanlarla \u00e7al\u0131\u015f\u0131rken \u00e7e\u015fitli end\u00fcstriyel ve ticari ortamlarda do\u011fru kurulum ve uyumlulu\u011fu sa\u011flamak i\u00e7in \u00e7ok \u00f6nemlidir.<\/p>\n<h2>PG \u0130plik \u00d6zellikleri<\/h2>\n<p>Alman standartlar\u0131ndan kaynaklanan PG (Panzergewinde) vida di\u015fleri, kendilerini NPT ve metrik vida di\u015flerinden ay\u0131ran farkl\u0131 \u00f6zelliklere sahip bir ba\u015fka yayg\u0131n kablo rakoru vida di\u015fi t\u00fcr\u00fcd\u00fcr. Bu di\u015fler d\u00fcz, silindirik profilleriyle karakterize edilir ve \"PG\" \u00f6n ekinin ard\u0131ndan standartla\u015ft\u0131r\u0131lm\u0131\u015f bir numara ile tan\u0131mlan\u0131r (\u00f6rn. PG 11, PG 16).<\/p>\n<p>PG di\u015flerin en \u00f6nemli \u00f6zelliklerinden biri, NPT ve metrik di\u015flerde bulunan 60\u00b0'lik a\u00e7\u0131dan farkl\u0131 olarak 80\u00b0'lik yan a\u00e7\u0131ya sahip olmalar\u0131d\u0131r. Bu daha geni\u015f a\u00e7\u0131, di\u015fin benzersiz profiline katk\u0131da bulunur ve s\u0131zd\u0131rmazl\u0131k \u00f6zelliklerini etkiler. PG di\u015fleri tipik olarak metrik di\u015flere k\u0131yasla daha kaba bir hatveye sahiptir, bu da h\u0131zl\u0131 montaj veya demontaj\u0131n gerekli oldu\u011fu baz\u0131 uygulamalarda avantajl\u0131 olabilir.<\/p>\n<p>PG di\u015f boyutlar\u0131 standartla\u015ft\u0131r\u0131lm\u0131\u015ft\u0131r ve her boyut belirli bir nominal \u00e7apa kar\u015f\u0131l\u0131k gelecek \u015fekilde PG 7 ile PG 48 aras\u0131nda de\u011fi\u015fir. \u00d6rne\u011fin:<\/p>\n<ul>\n<li>PG 11'in nominal \u00e7ap\u0131 18,6 mm'dir<\/li>\n<li>PG 16'n\u0131n nominal \u00e7ap\u0131 22,5 mm'dir<\/li>\n<li>PG 21'in nominal \u00e7ap\u0131 28,3 mm'dir<\/li>\n<\/ul>\n<p>PG vida di\u015flerinin baz\u0131 sekt\u00f6rlerde ve b\u00f6lgelerde hala yayg\u0131n olarak kullan\u0131lmas\u0131na ra\u011fmen, bir\u00e7ok uygulamada metrik vida di\u015fleri lehine kademeli olarak kullan\u0131mdan kald\u0131r\u0131ld\u0131\u011f\u0131n\u0131 belirtmek \u00f6nemlidir. Bu de\u011fi\u015fimin ba\u015fl\u0131ca nedeni uluslararas\u0131 standardizasyon \u00e7abalar\u0131 ve metrik di\u015flerin \u00e7ok y\u00f6nl\u00fcl\u00fc\u011f\u00fcd\u00fcr.<\/p>\n<p>PG di\u015flerle \u00e7al\u0131\u015f\u0131rken, kullan\u0131lan ekipman ve muhafazalarla uyumlulu\u011fun sa\u011flanmas\u0131 \u00e7ok \u00f6nemlidir. Bir\u00e7ok \u00fcretici, \u00f6ncelikle metrik veya NPT ba\u011flant\u0131lar\u0131 i\u00e7in tasarlanm\u0131\u015f sistemlerde PG di\u015flerini bar\u0131nd\u0131rmak i\u00e7in adapt\u00f6rler veya ge\u00e7i\u015f ba\u011flant\u0131 par\u00e7alar\u0131 sunar.<\/p>\n<p>Azalan kullan\u0131mlar\u0131na ra\u011fmen PG di\u015fleri, \u00f6zellikle Avrupa pazarlar\u0131nda belirli eski sistemlerde ve \u00f6zel uygulamalarda ge\u00e7erlili\u011fini korumaktad\u0131r. Benzersiz \u00f6zelliklerini ve boyutland\u0131rma kurallar\u0131n\u0131 anlamak, \u00e7e\u015fitli kablo rakoru sistemleriyle \u00e7al\u0131\u015fan veya eski ekipmanlar\u0131n bak\u0131m\u0131n\u0131 yapan profesyoneller i\u00e7in \u00e7ok \u00f6nemlidir.<\/p>\n<h2>G\u00f6rsel Denetim \u0130pu\u00e7lar\u0131<\/h2>\n<p>Kablo rakoru di\u015flerini g\u00f6rsel olarak incelerken, tipi do\u011fru bir \u015fekilde tan\u0131mlamak i\u00e7in temel \u00f6zelliklere odaklan\u0131n:<\/p>\n<ul>\n<li><strong>NPT di\u015fleri:<\/strong> Konik bir profil ve kesirli boyut i\u015faretleri (\u00f6rn. 1\/2\u2033 NPT) aray\u0131n. Di\u015fler uca do\u011fru daral\u0131yor gibi g\u00f6r\u00fcnecektir.<\/li>\n<li><strong>Metrik di\u015fler:<\/strong> \"M\" \u00f6n eki ve ard\u0131ndan milimetre cinsinden d\u0131\u015f \u00e7ap ile tan\u0131mlay\u0131n (\u00f6rn. M20). Bu di\u015fler d\u00fcz, silindirik bir profile sahiptir.<\/li>\n<li><strong>PG konular\u0131:<\/strong> \"PG\" \u00f6n eki ve standartla\u015ft\u0131r\u0131lm\u0131\u015f bir numara (\u00f6rn. PG 11) ile tan\u0131n\u0131r. Daha geni\u015f hatveye ve d\u00fcz profile dikkat edin.<\/li>\n<\/ul>\n<p>Di\u015f a\u00e7\u0131s\u0131na, hatveye ve genel \u015fekle dikkat edin. NPT ve metrik di\u015fler 60\u00b0 yan a\u00e7\u0131ya sahipken PG di\u015fler 80\u00b0 a\u00e7\u0131ya sahiptir. Emin de\u011filseniz, kesin tan\u0131mlama i\u00e7in bir di\u015f \u00f6l\u00e7er kullan\u0131n veya \u00fcretici spesifikasyonlar\u0131na ba\u015fvurun.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Cable gland thread types, including NPT, Metric, and PG, are crucial components in electrical installations, each serving specific purposes and applications. Understanding how to identify these thread types is essential for ensuring proper fit, sealing, and compatibility in various industrial and commercial settings. VIOX Cable Gland Connector NPT Thread Characteristics Credit to inpart24 NPT (National [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":7285,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1],"tags":[],"class_list":["post-10375","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"_links":{"self":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/posts\/10375","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/comments?post=10375"}],"version-history":[{"count":0,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/posts\/10375\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/media\/7285"}],"wp:attachment":[{"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/media?parent=10375"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/categories?post=10375"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/test.viox.com\/tr\/wp-json\/wp\/v2\/tags?post=10375"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}