{"id":5588,"date":"2024-09-13T16:35:55","date_gmt":"2024-09-13T08:35:55","guid":{"rendered":"https:\/\/viox.com\/?post_type=product&#038;p=5588"},"modified":"2024-09-13T16:39:17","modified_gmt":"2024-09-13T08:39:17","slug":"viox-vrc1-125-b-100a-2p-rccb","status":"publish","type":"product","link":"https:\/\/test.viox.com\/tl\/product\/viox-vrc1-125-b-100a-2p-rccb\/","title":{"rendered":"VIOX VRC1-125-B 100A 2P RCCB"},"content":{"rendered":"<div class=\"product-intro\">\n<h2>VIOX VRC1-125-B 100A 2P RCCB Nalalabing Kasalukuyang Circuit Breaker<\/h2>\n<h2>Pangkalahatang-ideya<\/h2>\n<p>Ang VIOX VRC1-125-B ay isang high-performance Residual Current Circuit Breaker (RCCB) na idinisenyo para sa superyor na proteksyon laban sa mga earth fault at electric leakage. Sa pamamagitan ng mga advanced na feature at maaasahang pagganap nito, tinitiyak ng RCCB na ito ang pinahusay na kaligtasan sa iba't ibang electrical installations.<\/p>\n<h2>Mga Pangunahing Tampok<\/h2>\n<ul>\n<li>Ergonomic na cambered cover at handle para sa komportableng operasyon<\/li>\n<li>Contact position indication window para sa madaling pag-check ng status<\/li>\n<li>Transparent clamshell na may label para sa malinaw na pagkakakilanlan<\/li>\n<li>Mabilis na pagtukoy ng fault sa pamamagitan ng handle tripping sa gitnang posisyon<\/li>\n<li>Earth fault, electric leakage, at isolation protection functions<\/li>\n<li>Mataas na short circuit current tolerance<\/li>\n<li>Finger-protection wiring terminal para sa dagdag na kaligtasan<\/li>\n<li>High flame-resisting, temperature-resisting, at impact-resisting engineering plastic construction<\/li>\n<li>Automatic circuit cut-off kapag ang earth fault o electric leakage ay lumampas sa itinakdang halaga<\/li>\n<li>Independent dynamic at wire pressure, hindi apektado ng mga panlabas na disturbances at voltage fluctuations<\/li>\n<\/ul>\n<h2>Teknikal na Pagtutukoy<\/h2>\n<ul>\n<li>Standard: IEC61008-1, IEC62423<\/li>\n<li>Type: Electronic type (Auxiliary Electromagnetic type)<\/li>\n<li>Characteristics ng residual operation current: Type B<\/li>\n<li>Poles: 2P (1P+N, 3P+N available)<\/li>\n<li>Rated operating break capability: 10 InA<\/li>\n<li>Rated current: 100A (25A, 40A, 63A also available)<\/li>\n<li>Rated voltage: AC 240\/415V<\/li>\n<li>Rated frequency: 50\/60 Hz<\/li>\n<li>Rated residual operation current (I\u25b3n): 0.03A, 0.1A, 0.3A<\/li>\n<li>Rated residual non-operating current: 0.5I\u25b3n<\/li>\n<li>Rated limited short circuit current: 10 kA<\/li>\n<li>Rated limited residual short circuit current: 10 kA<\/li>\n<li>Scope ng residual operating current: 0.5I\u25b3n~I\u25b3n<\/li>\n<li>Mechanical electrical life: 4,000 cycles<\/li>\n<li>Wiring section area ng terminal: conductor ng 25 mm\u00b2 at pababa<\/li>\n<li>Installation: 35.5mm guide rail \/ Vertical installation<\/li>\n<li>Enclosure protection class: IP20<\/li>\n<\/ul>\n<div class=\"table_wrap\">\n<h2><b>Mga Pangunahing Parameter<\/b><\/h2>\n<table border=\"0\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"136\" \/>\n<col width=\"268\" \/>\n<col width=\"243\" \/>\n<col width=\"173\" \/>\n<col width=\"58\" \/>\n<col width=\"66\" \/>\n<col width=\"217\" \/>\n<col width=\"69\" \/><\/colgroup>\n<tbody>\n<tr>\n<td width=\"136\" height=\"81\">Na-rate ang kasalukuyang<br \/>\nng housing<br \/>\ngrade Inm(A)<\/td>\n<td width=\"268\">Pole<\/td>\n<td width=\"243\">Dalas<br \/>\n(Hz)<\/td>\n<td width=\"173\">Rated voltage<br \/>\nUe(V)<\/td>\n<td width=\"58\">Na-rate ang kasalukuyang<br \/>\nSa(A)<\/td>\n<td width=\"66\">Rated residual<br \/>\ncurrent(A)<\/td>\n<td width=\"217\">Rated limited<br \/>\nmaikling circuit<br \/>\ncurrent Inc(A)<\/td>\n<td width=\"69\">Rated limited<br \/>\nresidual short<br \/>\ncircuit current<br \/>\nI\u25b3C(A)<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" height=\"36\">63<\/td>\n<td>1P+N<\/td>\n<td rowspan=\"2\">50\/60Hz<\/td>\n<td align=\"right\">240<\/td>\n<td rowspan=\"2\">25 40 63<\/td>\n<td rowspan=\"2\">0.03 0.1 0.3<\/td>\n<td rowspan=\"2\">10000<\/td>\n<td rowspan=\"2\">10000<\/td>\n<\/tr>\n<tr>\n<td>3P+N<\/td>\n<td align=\"right\">415<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>&nbsp;<\/p>\n<p><b>Standard value ng breaking time at non-operating time para sa pulse DC residual current at smooth DC residual current na ginawa ng rectifying circuit<\/b><\/p>\n<div class=\"table_wrap\">\n<table border=\"0\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"136\" \/>\n<col width=\"268\" \/>\n<col width=\"243\" \/>\n<col width=\"173\" \/>\n<col width=\"58\" \/>\n<col width=\"66\" \/>\n<col width=\"217\" \/><\/colgroup>\n<tbody>\n<tr>\n<td rowspan=\"2\" width=\"136\" height=\"78\">Uri<\/td>\n<td rowspan=\"2\" width=\"268\">Sa(A)<\/td>\n<td rowspan=\"2\" width=\"243\">I\u25b3n(A)<\/td>\n<td colspan=\"4\" width=\"514\">Standard value ng breaking time at non-operating time para sa equality ng residual<br \/>\ncurrent (I\u25b3A ) at sumusunod na mga halaga (S)<\/td>\n<\/tr>\n<tr>\n<td>2 I\u25b3n<\/td>\n<td>4 I\u25b3n<\/td>\n<td>10 I\u25b3n<\/td>\n<td>5A,10A,20A,50A,100A,200A<\/td>\n<\/tr>\n<tr>\n<td height=\"18\">Pangkalahatang uri<\/td>\n<td>Anumang halaga<\/td>\n<td>Anumang halaga<\/td>\n<td>0.3<\/td>\n<td>0.15<\/td>\n<td>0.04<\/td>\n<td>0.04<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>&nbsp;<\/p>\n<p><b>Range ng tripping current(Table 1)<\/b><\/p>\n<div class=\"table_wrap\">\n<table border=\"0\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"136\" \/>\n<col width=\"268\" \/>\n<col width=\"243\" \/>\n<col width=\"173\" \/><\/colgroup>\n<tbody>\n<tr>\n<td width=\"136\" height=\"18\">Modelo<\/td>\n<td colspan=\"3\" width=\"684\">Tripping current I\u25b3 \/A<\/td>\n<\/tr>\n<tr>\n<td height=\"18\">AC<\/td>\n<td colspan=\"3\">0.5 I\u25b3n\uff1cI\u25b3n<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\" height=\"72\">A<\/td>\n<td>Angle ng retard<\/td>\n<td>I\u25b3n&gt;0.01A<\/td>\n<td>I\u25b3n\uff1c0.01A<\/td>\n<\/tr>\n<tr>\n<td>0\u00b0<\/td>\n<td>0.35I\u25b3n\u2264I\u25b3\u22641.4I\u25b3n<\/td>\n<td>0.35I\u25b3n\u2264I\u25b3\u22642I\u25b3n<\/td>\n<\/tr>\n<tr>\n<td>90\u00b0<\/td>\n<td>0.25I\u25b3n\u2264I\u25b3\u22641.4I\u25b3n<\/td>\n<td>0.25I\u25b3n\u2264I\u25b3\u22642I\u25b3n<\/td>\n<\/tr>\n<tr>\n<td>135\u00b0<\/td>\n<td>0.1I\u25b3n\u2264I\u25b3\u22641.4I\u25b3n<\/td>\n<td>0.1I\u25b3n\u2264I\u25b3\u22642I\u25b3n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>&nbsp;<\/p>\n<p><b>Iba sa (B type) ng 50\/60 Hz ayon sa frequency(Table 2)<\/b><\/p>\n<div class=\"table_wrap\">\n<table border=\"0\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"136\" \/>\n<col width=\"268\" \/>\n<col width=\"243\" \/><\/colgroup>\n<tbody>\n<tr>\n<td width=\"136\" height=\"18\">Dalas (Hz)<\/td>\n<td width=\"268\">Natitirang hindi gumaganang kuryente<\/td>\n<td width=\"243\">Natitirang gumaganang kuryente<\/td>\n<\/tr>\n<tr>\n<td height=\"18\">150<\/td>\n<td>0.5I\u25b3n<\/td>\n<td>2.4I\u25b3n<\/td>\n<\/tr>\n<tr>\n<td height=\"18\">400<\/td>\n<td>0.5I\u25b3n<\/td>\n<td>6I\u25b3n<\/td>\n<\/tr>\n<tr>\n<td height=\"18\">1000<\/td>\n<td>I\u25b3n<\/td>\n<td>14I\u25b3n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2>Mga application<\/h2>\n<ul>\n<li>Mga de-koryenteng sistema ng tirahan<\/li>\n<li>Mga komersyal na gusali<\/li>\n<li>Mga instalasyong pang-industriya<\/li>\n<li>Mga board ng pamamahagi<\/li>\n<li>Proteksyon sa pagtagas ng lupa sa iba't ibang electrical circuit<\/li>\n<\/ul>\n<h2>Mga kalamangan<\/h2>\n<ul>\n<li>Pinahusay na kaligtasan na may maraming proteksyon na function<\/li>\n<li>Mataas na tolerance sa short circuit current para sa pinahusay na pagiging maaasahan<\/li>\n<li>Madaling pag-install at pagpapanatili<\/li>\n<li>I-clear ang indikasyon ng katayuan para sa mabilis na pagkakakilanlan ng kasalanan<\/li>\n<li>Matibay na konstruksyon para sa pangmatagalang pagganap<\/li>\n<li>Sumusunod sa mga internasyonal na pamantayan para sa katiyakan ng kalidad<\/li>\n<\/ul>\n<h2>Mga Tampok na Pangkaligtasan<\/h2>\n<ul>\n<li>Proteksyon ng kasalanan sa lupa<\/li>\n<li>Proteksyon sa pagtagas ng kuryente<\/li>\n<li>Proteksyon sa paghihiwalay<\/li>\n<li>Terminal ng mga kable na protektado ang daliri<\/li>\n<li>Awtomatikong pagputol ng circuit para sa mga fault na lumampas sa mga itinakdang halaga<\/li>\n<\/ul>\n<h2>Quality Assurance<\/h2>\n<p>Ang VIOX ay nakatuon sa pagbibigay ng mataas na kalidad na mga RCCB na nakakatugon sa mga internasyonal na pamantayan. Ang aming mga produkto ay sumasailalim sa mahigpit na pagsubok upang matiyak ang pagiging maaasahan, kaligtasan, at pangmatagalang pagganap sa iba't ibang mga electrical installation.<\/p>\n<h2>Pag-install<\/h2>\n<p>Ang VIOX VRC1-125-B RCCB ay idinisenyo para sa madaling pag-install sa 35.5mm na mga guide rail o vertical mounting. Ang compact na disenyo nito at malinaw na pag-label ay nagpapadali sa mabilis at mahusay na pag-install sa mga distribution board at electrical panel.<\/p>\n<h2>Dimensyon<\/h2>\n<h2>VRC1-125\uff0863A\uff09<\/h2>\n<p><a href=\"https:\/\/test.viox.com\/tl\/?attachment_id=5589\" rel=\"attachment wp-att-5590\"><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone wp-image-5589 size-full\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VRC1-125-B-100A-2P-RCCB-Residual-Current-Circuit-Breaker03.webp\" alt=\"\" width=\"1556\" height=\"528\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VRC1-125-B-100A-2P-RCCB-Residual-Current-Circuit-Breaker03.webp 1556w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VRC1-125-B-100A-2P-RCCB-Residual-Current-Circuit-Breaker03-300x102.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VRC1-125-B-100A-2P-RCCB-Residual-Current-Circuit-Breaker03-1024x347.webp 1024w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VRC1-125-B-100A-2P-RCCB-Residual-Current-Circuit-Breaker03-768x261.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VRC1-125-B-100A-2P-RCCB-Residual-Current-Circuit-Breaker03-1536x521.webp 1536w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VRC1-125-B-100A-2P-RCCB-Residual-Current-Circuit-Breaker03-600x204.webp 600w\" sizes=\"(max-width: 1556px) 100vw, 1556px\" \/><\/a><\/p>\n<h2>VRC1-125\uff08100A\uff09<\/h2>\n<p><a href=\"https:\/\/test.viox.com\/tl\/?attachment_id=5590\" rel=\"attachment wp-att-5590\"><img decoding=\"async\" class=\"alignnone size-full wp-image-5590\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VRC1-125-B-100A-2P-RCCB-Residual-Current-Circuit-Breaker02.webp\" alt=\"\" width=\"1594\" height=\"566\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VRC1-125-B-100A-2P-RCCB-Residual-Current-Circuit-Breaker02.webp 1594w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VRC1-125-B-100A-2P-RCCB-Residual-Current-Circuit-Breaker02-300x107.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VRC1-125-B-100A-2P-RCCB-Residual-Current-Circuit-Breaker02-1024x364.webp 1024w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VRC1-125-B-100A-2P-RCCB-Residual-Current-Circuit-Breaker02-768x273.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VRC1-125-B-100A-2P-RCCB-Residual-Current-Circuit-Breaker02-1536x545.webp 1536w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VRC1-125-B-100A-2P-RCCB-Residual-Current-Circuit-Breaker02-600x213.webp 600w\" sizes=\"(max-width: 1594px) 100vw, 1594px\" \/><\/a><\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<div class=\"msg-content MuiBox-root css-0\">\n<div class=\"break-words\">\n<p>Ang VIOX VRC1-125-B RCCB ay nag-aalok ng superyor na proteksyon laban sa mga earth fault at electric leakage para sa mga sistema hanggang 100A. Ang device na ito na sumusunod sa IEC61008-1 at IEC62423 ay nagtatampok ng 10kA na rated limited short circuit current at sumusuporta sa residual operation currents na 0.03A, 0.1A, at 0.3A. Available sa 2P configuration, ito ay gumagana sa 240\/415V AC, 50\/60Hz. Kabilang sa mga pangunahing bentahe ang Type B characteristics, IP20 protection, at 4,000-cycle mechanical life. Sa pamamagitan ng ergonomic na disenyo nito, contact position indication, at finger-protection terminals, tinitiyak ng RCCB na ito ang madaling operasyon at pinahusay na kaligtasan. Angkop para sa residential, commercial, at industrial na mga aplikasyon, nag-aalok ito ng automatic circuit cut-off at mataas na short circuit tolerance. Ang flame-resistant at impact-resistant na konstruksyon ng device, kasama ang 25mm\u00b2 terminal capacity at 35.5mm DIN rail mounting, ay ginagawa itong perpekto para sa iba't ibang pangangailangan sa proteksyon ng earth leakage sa mga distribution board at electrical circuits.<\/p>\n<\/div>\n<\/div>","protected":false},"featured_media":5591,"comment_status":"closed","ping_status":"closed","template":"","meta":{"inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[],"product_cat":[116,131],"product_tag":[],"class_list":{"0":"post-5588","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-low-voltage-protection-devices","7":"product_cat-rccb","8":"desktop-align-left","9":"tablet-align-left","10":"mobile-align-left","12":"first","13":"instock","14":"shipping-taxable","15":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/test.viox.com\/tl\/wp-json\/wp\/v2\/product\/5588","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/test.viox.com\/tl\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/test.viox.com\/tl\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/test.viox.com\/tl\/wp-json\/wp\/v2\/comments?post=5588"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/test.viox.com\/tl\/wp-json\/wp\/v2\/media\/5591"}],"wp:attachment":[{"href":"https:\/\/test.viox.com\/tl\/wp-json\/wp\/v2\/media?parent=5588"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/test.viox.com\/tl\/wp-json\/wp\/v2\/product_brand?post=5588"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/test.viox.com\/tl\/wp-json\/wp\/v2\/product_cat?post=5588"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/test.viox.com\/tl\/wp-json\/wp\/v2\/product_tag?post=5588"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}