{"id":5547,"date":"2024-09-13T13:59:12","date_gmt":"2024-09-13T05:59:12","guid":{"rendered":"https:\/\/viox.com\/?post_type=product&#038;p=5547"},"modified":"2024-09-13T14:05:35","modified_gmt":"2024-09-13T06:05:35","slug":"viox-v50l-32g-safety-breaker-rcbo","status":"publish","type":"product","link":"https:\/\/test.viox.com\/tl\/product\/viox-v50l-32g-safety-breaker-rcbo\/","title":{"rendered":"VIOX V50L-32G Safety Breaker RCBO"},"content":{"rendered":"<div class=\"product-intro\">\n<h2>VIOX V50L-32G Safety Breaker Natitirang Kasalukuyang Circuit Breaker na may Overcurrent na Proteksyon<\/h2>\n<h2>Pangkalahatang-ideya<\/h2>\n<p>Ang VIOX V50L-32G RCBO series ay idinisenyo para sa AC 50Hz na mga application na may rate na boltahe hanggang 240V at rated kasalukuyang hanggang 32A. Nag-aalok ang mga device na ito ng komprehensibong proteksyon laban sa overload at short circuit para sa iba&#039;t ibang modernong kagamitan sa sambahayan, habang nagbibigay din ng functionality para sa madalang na operasyon at kontrol.<\/p>\n<h2>Mga Pangunahing Tampok<\/h2>\n<ul>\n<li>Mataas na kapasidad ng pagsira<\/li>\n<li>Zero line at fire line na pasulput-sulpot na proteksyon<\/li>\n<li>Proteksyon sa pagtagas kahit na sa kaso ng pagkabaligtad ng linya ng apoy<\/li>\n<li>Compact size na may double pole structure na disenyo<\/li>\n<li>Sabay-sabay na koneksyon at pagtatanggal ng magkabilang poste<\/li>\n<li>Tunay na ligtas at maaasahan para sa sibilyan at pang-industriya na single-phase na aplikasyon<\/li>\n<li>Angkop para sa madalang na operasyon at kontrol<\/li>\n<\/ul>\n<h2>Teknikal na Pagtutukoy<\/h2>\n<ul>\n<li>Pamantayan: IEC\/EN 60898<\/li>\n<li>Uri: RCBO V50L-32G<\/li>\n<li>Proteksyon: Overload at Short Circuit<\/li>\n<li>Rated kasalukuyang: 16A, 20A, 25A, 32A<\/li>\n<li>Katangian: C curve (32A), D curve (16A, 20A, 25A)<\/li>\n<li>Mga poste: 2 poste<\/li>\n<li>Pagsira kapasidad: 2500A<\/li>\n<li>Na-rate na boltahe: 110VAC, 230VAC<\/li>\n<li>Ambient Temperature: -5\u00b0C hanggang +40\u00b0C (24-hour average na hindi hihigit sa 35\u00b0C)<\/li>\n<li>Altitude: 2,000m o mas mababa<\/li>\n<li>Klase ng pag-install: III<\/li>\n<li>Mga antas ng polusyon: II<\/li>\n<\/ul>\n<table border=\"1\">\n<thead>\n<tr>\n<th colspan=\"6\">Over-Load<\/th>\n<\/tr>\n<tr>\n<th>Pagsusulit Blg.<\/th>\n<th>Curve Ng Uri Ng<\/th>\n<th>Mag-load ng Kasalukuyan<\/th>\n<th>Paunang Estado<\/th>\n<th>Limitasyon ng Oras sa Paglalakbay<\/th>\n<th>Tinatayang Resulta<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td>C,D<\/td>\n<td>1.13Sa<\/td>\n<td>malamig na estado<\/td>\n<td>t\u22641h<\/td>\n<td>Hindi trip<\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>C,D<\/td>\n<td>1.45In<\/td>\n<td>pagpapatuloy ng pagsusulit<\/td>\n<td>t &lt; 1<\/td>\n<td>trip<\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>C,D<\/td>\n<td>2.55In<\/td>\n<td>malamig na estado<\/td>\n<td>1s &lt; t &lt; 60s<\/td>\n<td>trip<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"1\">\n<thead>\n<tr>\n<th colspan=\"6\">Maikling circuit<\/th>\n<\/tr>\n<tr>\n<th>Pagsusulit Blg.<\/th>\n<th>Curve Ng Uri Ng<\/th>\n<th>Mag-load ng Kasalukuyan<\/th>\n<th>Paunang Estado<\/th>\n<th>Limitasyon ng Oras sa Paglalakbay<\/th>\n<th>Tinatayang Resulta<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td rowspan=\"2\">4<\/td>\n<td>C<\/td>\n<td>5Sa<\/td>\n<td rowspan=\"2\">malamig na estado<\/td>\n<td rowspan=\"2\">t\u22640.1s<\/td>\n<td rowspan=\"2\">Hindi trip<\/td>\n<\/tr>\n<tr>\n<td>D<\/td>\n<td>10Sa<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">5<\/td>\n<td>C<\/td>\n<td>10Sa<\/td>\n<td rowspan=\"2\">malamig na estado<\/td>\n<td rowspan=\"2\">t &lt; 0.1s<\/td>\n<td rowspan=\"2\">trip<\/td>\n<\/tr>\n<tr>\n<td>D<\/td>\n<td>20Sa<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"1\">\n<thead>\n<tr>\n<th>Temperatura ng kapaligiran Rated kasalukuyang(A)<\/th>\n<th>-10\u00b0C<\/th>\n<th>0\u00b0C<\/th>\n<th>10\u00b0C<\/th>\n<th>20\u00b0C<\/th>\n<th>30\u00b0C<\/th>\n<th>40\u00b0C<\/th>\n<th>50\u00b0C<\/th>\n<th>60\u00b0C<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>16<\/td>\n<td>19.20<\/td>\n<td>18.40<\/td>\n<td>17.76<\/td>\n<td>16.96<\/td>\n<td>16.00<\/td>\n<td>15.36<\/td>\n<td>14.88<\/td>\n<td>14.24<\/td>\n<\/tr>\n<tr>\n<td>20<\/td>\n<td>24.00<\/td>\n<td>23.00<\/td>\n<td>22.20<\/td>\n<td>21.20<\/td>\n<td>20.00<\/td>\n<td>19.20<\/td>\n<td>18.60<\/td>\n<td>17.80<\/td>\n<\/tr>\n<tr>\n<td>25<\/td>\n<td>30.00<\/td>\n<td>28.75<\/td>\n<td>27.75<\/td>\n<td>26.50<\/td>\n<td>25.00<\/td>\n<td>24.00<\/td>\n<td>23.25<\/td>\n<td>22.25<\/td>\n<\/tr>\n<tr>\n<td>32<\/td>\n<td>38.72<\/td>\n<td>37.12<\/td>\n<td>35.52<\/td>\n<td>33.92<\/td>\n<td>32.00<\/td>\n<td>30.72<\/td>\n<td>29.76<\/td>\n<td>28.16<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Mga Kinakailangan sa Pag-install<\/h2>\n<ul>\n<li>Ang magnetic field na malapit sa lugar ng pag-install ay hindi dapat higit sa limang beses ang magnetic field sa anumang direksyon<\/li>\n<\/ul>\n<h2>Mga application<\/h2>\n<ul>\n<li>Proteksyon ng mga modernong kagamitan sa bahay<\/li>\n<li>Sibilyan at pang-industriya na single-phase circuit<\/li>\n<li>Mga senaryo ng madalang na operasyon at kontrol<\/li>\n<\/ul>\n<h2>Mga Tampok na Pangkaligtasan<\/h2>\n<ul>\n<li>Proteksyon ng dalawahang poste<\/li>\n<li>Proteksyon sa pagtagas sa iba&#039;t ibang mga senaryo ng mga kable<\/li>\n<li>Sabay-sabay na operasyon ng poste para sa pinahusay na kaligtasan<\/li>\n<\/ul>\n<h2>Kurba ng Katangian<\/h2>\n<p><a href=\"https:\/\/test.viox.com\/tl\/?attachment_id=5548\" rel=\"attachment wp-att-5548\"><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone wp-image-5548\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-V50L-32G-Safety-Breaker-Residual-Current-Circuit-Breaker-with-Overcurrent-Protection04.webp\" alt=\"\" width=\"458\" height=\"638\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-V50L-32G-Safety-Breaker-Residual-Current-Circuit-Breaker-with-Overcurrent-Protection04.webp 658w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-V50L-32G-Safety-Breaker-Residual-Current-Circuit-Breaker-with-Overcurrent-Protection04-216x300.webp 216w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-V50L-32G-Safety-Breaker-Residual-Current-Circuit-Breaker-with-Overcurrent-Protection04-600x835.webp 600w\" sizes=\"(max-width: 458px) 100vw, 458px\" \/><\/a><\/p>\n<h2>Wiring Diagram<\/h2>\n<p><a href=\"https:\/\/test.viox.com\/tl\/?attachment_id=5551\" rel=\"attachment wp-att-5551\"><img decoding=\"async\" class=\"alignnone wp-image-5551\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-V50L-32G-Safety-Breaker-Residual-Current-Circuit-Breaker-with-Overcurrent-Protection03.webp\" alt=\"\" width=\"421\" height=\"332\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-V50L-32G-Safety-Breaker-Residual-Current-Circuit-Breaker-with-Overcurrent-Protection03.webp 584w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-V50L-32G-Safety-Breaker-Residual-Current-Circuit-Breaker-with-Overcurrent-Protection03-300x236.webp 300w\" sizes=\"(max-width: 421px) 100vw, 421px\" \/><\/a><\/p>\n<h2>Dimensyon<\/h2>\n<p><a href=\"https:\/\/test.viox.com\/tl\/?attachment_id=5549\" rel=\"attachment wp-att-5549\"><img decoding=\"async\" class=\"alignnone wp-image-5549\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-V50L-32G-Safety-Breaker-Residual-Current-Circuit-Breaker-with-Overcurrent-Protection02.webp\" alt=\"\" width=\"671\" height=\"265\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-V50L-32G-Safety-Breaker-Residual-Current-Circuit-Breaker-with-Overcurrent-Protection02.webp 1534w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-V50L-32G-Safety-Breaker-Residual-Current-Circuit-Breaker-with-Overcurrent-Protection02-300x119.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-V50L-32G-Safety-Breaker-Residual-Current-Circuit-Breaker-with-Overcurrent-Protection02-1024x405.webp 1024w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-V50L-32G-Safety-Breaker-Residual-Current-Circuit-Breaker-with-Overcurrent-Protection02-768x303.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-V50L-32G-Safety-Breaker-Residual-Current-Circuit-Breaker-with-Overcurrent-Protection02-600x237.webp 600w\" sizes=\"(max-width: 671px) 100vw, 671px\" \/><\/a><\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<div class=\"msg-content MuiBox-root css-0\">\n<div class=\"break-words\">\n<p>Nag-aalok ang VIOX V50L-32G RCBO ng komprehensibong proteksyon para sa mga AC 50Hz na application hanggang 240V at 32A. Nagtatampok ang IEC\/EN 60898 compliant na device na ito ng 2500A breaking capacity at nagbibigay ng dual-pole na proteksyon laban sa mga overload, short circuit, at leakage currents. Available sa 16A, 20A, 25A, at 32A na rating na may C at D tripping curves, perpekto ito para sa mga modernong gamit sa bahay at single-phase industrial circuit. Kabilang sa mga pangunahing bentahe ang compact na disenyo, zero line at proteksyon ng fire line, at maaasahang operasyon kahit na may reversed wiring. Gumagana mula -5\u00b0C hanggang +40\u00b0C at angkop para sa mga altitude hanggang 2000m, tinitiyak ng versatile RCBO na ito ang kaligtasan sa iba&#039;t ibang kapaligiran. Ang madalang na kakayahan nito sa pagpapatakbo at sabay-sabay na pagkakadiskonekta ng poste ay ginagawa itong tunay na mapagkakatiwalaang pagpipilian para sa parehong tirahan at magaan na pang-industriya na aplikasyon.<\/p>\n<\/div>\n<\/div>","protected":false},"featured_media":5550,"comment_status":"closed","ping_status":"closed","template":"","meta":{"inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[],"product_cat":[116,129],"product_tag":[],"class_list":{"0":"post-5547","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-low-voltage-protection-devices","7":"product_cat-rcbo","8":"desktop-align-left","9":"tablet-align-left","10":"mobile-align-left","12":"first","13":"instock","14":"shipping-taxable","15":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/test.viox.com\/tl\/wp-json\/wp\/v2\/product\/5547","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/test.viox.com\/tl\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/test.viox.com\/tl\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/test.viox.com\/tl\/wp-json\/wp\/v2\/comments?post=5547"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/test.viox.com\/tl\/wp-json\/wp\/v2\/media\/5550"}],"wp:attachment":[{"href":"https:\/\/test.viox.com\/tl\/wp-json\/wp\/v2\/media?parent=5547"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/test.viox.com\/tl\/wp-json\/wp\/v2\/product_brand?post=5547"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/test.viox.com\/tl\/wp-json\/wp\/v2\/product_cat?post=5547"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/test.viox.com\/tl\/wp-json\/wp\/v2\/product_tag?post=5547"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}