{"id":5525,"date":"2024-09-13T09:12:59","date_gmt":"2024-09-13T01:12:59","guid":{"rendered":"https:\/\/viox.com\/?post_type=product&#038;p=5525"},"modified":"2024-09-13T09:13:38","modified_gmt":"2024-09-13T01:13:38","slug":"viox-cjx2-3211-ac-contactor","status":"publish","type":"product","link":"https:\/\/test.viox.com\/pt\/produto\/viox-cjx2-3211-ac-contactor\/","title":{"rendered":"Contactor CA VIOX CJX2-3211"},"content":{"rendered":"<div class=\"product-intro\">\n<h2>Contactor CA da s\u00e9rie CJX2: Solu\u00e7\u00e3o vers\u00e1til de controlo de pot\u00eancia<\/h2>\n<p>O contactor CA da s\u00e9rie CJX2 \u00e9 um dispositivo avan\u00e7ado de controlo de pot\u00eancia concebido para uma vasta gama de aplica\u00e7\u00f5es el\u00e9ctricas. Este contactor robusto foi concebido para funcionar eficientemente em circuitos com tens\u00f5es nominais at\u00e9 660V CA a 50Hz ou 60Hz, e pode lidar com correntes nominais at\u00e9 95A. As suas principais fun\u00e7\u00f5es incluem a cria\u00e7\u00e3o e interrup\u00e7\u00e3o de circuitos, bem como o arranque e controlo frequentes de motores CA.<\/p>\n<p>Uma das principais vantagens da s\u00e9rie CJX2 \u00e9 a sua excecional versatilidade. Quando combinada com componentes auxiliares, tais como blocos de contacto, atrasos temporizados e dispositivos de encravamento de m\u00e1quinas, pode ser transformada em unidades especializadas como:<\/p>\n<ul>\n<li>Contactores de atraso<\/li>\n<li>Contactores mec\u00e2nicos de encravamento<\/li>\n<li>Arrancadores estrela-delta<\/li>\n<\/ul>\n<p>Al\u00e9m disso, quando emparelhada com um rel\u00e9 t\u00e9rmico, a s\u00e9rie CJX2 pode funcionar como um arrancador eletromagn\u00e9tico abrangente, oferecendo capacidades de prote\u00e7\u00e3o e controlo melhoradas.<\/p>\n<p>Este contactor de alto desempenho \u00e9 fabricado em estrita conformidade com a norma IEC 60947-4-1, garantindo fiabilidade, seguran\u00e7a e compatibilidade em v\u00e1rias aplica\u00e7\u00f5es industriais.<\/p>\n<p>Quer esteja a gerir controlos de motores, sistemas de ilumina\u00e7\u00e3o ou outras necessidades de distribui\u00e7\u00e3o de energia, o contactor CA da s\u00e9rie CJX2 fornece uma solu\u00e7\u00e3o flex\u00edvel e fi\u00e1vel para os seus requisitos de controlo el\u00e9trico.<\/p>\n<h2 class=\"fl-heading\"><span class=\"fl-heading-text\">Tens\u00e3o da bobina do contactor CA e c\u00f3digo<\/span><\/h2>\n<table border=\"1\" cellpadding=\"5\">\n<tbody>\n<tr>\n<th>Tens\u00e3o da bobina<br \/>\nN\u00f3s(V)<\/th>\n<th>24<\/th>\n<th>36<\/th>\n<th>42<\/th>\n<th>48<\/th>\n<th>110<\/th>\n<th>220<\/th>\n<th>230<\/th>\n<th>240<\/th>\n<th>380<\/th>\n<th>400<\/th>\n<th>415<\/th>\n<th>440<\/th>\n<th>600<\/th>\n<\/tr>\n<tr>\n<th>50Hz<\/th>\n<td>B5<\/td>\n<td>C5<\/td>\n<td>D5<\/td>\n<td>E5<\/td>\n<td>F5<\/td>\n<td>M5<\/td>\n<td>P5<\/td>\n<td>U5<\/td>\n<td>Q5<\/td>\n<td>V5<\/td>\n<td>N5<\/td>\n<td>R5<\/td>\n<td>X5<\/td>\n<\/tr>\n<tr>\n<th>60Hz<\/th>\n<td>B6<\/td>\n<td>C6<\/td>\n<td>D6<\/td>\n<td>E6<\/td>\n<td>F6<\/td>\n<td>M6<\/td>\n<td>P6<\/td>\n<td>U6<\/td>\n<td>Q6<\/td>\n<td>V6<\/td>\n<td>N6<\/td>\n<td>R6<\/td>\n<td>X6<\/td>\n<\/tr>\n<tr>\n<th>50\/60Hz<\/th>\n<td>B7<\/td>\n<td>C7<\/td>\n<td>D7<\/td>\n<td>E7<\/td>\n<td>F7<\/td>\n<td>M7<\/td>\n<td>P7<\/td>\n<td>U7<\/td>\n<td>Q7<\/td>\n<td>V7<\/td>\n<td>N7<\/td>\n<td>R7<\/td>\n<td>X7<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2 class=\"fl-heading\"><span class=\"fl-heading-text\">Tipo Designa\u00e7\u00e3o<\/span><\/h2>\n<table border=\"1\" cellpadding=\"5\">\n<tbody>\n<tr>\n<th>Nome<\/th>\n<th>Corrente nominal<\/th>\n<th>Contacto auxiliar<\/th>\n<th>N\u00famero do p\u00f3lo<\/th>\n<th>Tens\u00e3o da bobina<\/th>\n<th>Frequ\u00eancia<\/th>\n<\/tr>\n<tr>\n<td>CJX2<\/td>\n<td>\n<div style=\"width: 50px; height: 20px; border: 1px solid black;\"><\/div>\n<\/td>\n<td>\n<div style=\"width: 50px; height: 20px; border: 1px solid black;\"><\/div>\n<\/td>\n<td>\n<div style=\"width: 50px; height: 20px; border: 1px solid black;\"><\/div>\n<\/td>\n<td>*<\/td>\n<td>.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"1\" cellpadding=\"5\">\n<tbody>\n<tr>\n<th rowspan=\"2\">Corrente nominal (A)<\/th>\n<th colspan=\"2\">Contacto auxiliar<\/th>\n<th rowspan=\"2\">Tipo<\/th>\n<\/tr>\n<tr>\n<th>Normal aberto (NO)<\/th>\n<th>Fecho normal (NC)<\/th>\n<\/tr>\n<tr>\n<td rowspan=\"2\">9<\/td>\n<td>1<\/td>\n<td>&#8211;<\/td>\n<td>CJX2-0910*.<\/td>\n<\/tr>\n<tr>\n<td>&#8211;<\/td>\n<td>1<\/td>\n<td>CJX2-0901*.<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">12<\/td>\n<td>1<\/td>\n<td>&#8211;<\/td>\n<td>CJX2-1210*.<\/td>\n<\/tr>\n<tr>\n<td>&#8211;<\/td>\n<td>1<\/td>\n<td>CJX2-1201*.<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">18<\/td>\n<td>1<\/td>\n<td>&#8211;<\/td>\n<td>CJX2-1810*.<\/td>\n<\/tr>\n<tr>\n<td>&#8211;<\/td>\n<td>1<\/td>\n<td>CJX2-1801*.<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">25<\/td>\n<td>1<\/td>\n<td>&#8211;<\/td>\n<td>CJX2-2510*.<\/td>\n<\/tr>\n<tr>\n<td>&#8211;<\/td>\n<td>1<\/td>\n<td>CJX2-2501*.<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">32<\/td>\n<td>1<\/td>\n<td>&#8211;<\/td>\n<td>CJX2-3210*.<\/td>\n<\/tr>\n<tr>\n<td>&#8211;<\/td>\n<td>1<\/td>\n<td>CJX2-3201*.<\/td>\n<\/tr>\n<tr>\n<td>40<\/td>\n<td>1<\/td>\n<td>1<\/td>\n<td>CJX2-4011*.<\/td>\n<\/tr>\n<tr>\n<td>50<\/td>\n<td>1<\/td>\n<td>1<\/td>\n<td>CJX2-5011*.<\/td>\n<\/tr>\n<tr>\n<td>65<\/td>\n<td>1<\/td>\n<td>1<\/td>\n<td>CJX2-6511*.<\/td>\n<\/tr>\n<tr>\n<td>80<\/td>\n<td>1<\/td>\n<td>1<\/td>\n<td>CJX2-8011*.<\/td>\n<\/tr>\n<tr>\n<td>95<\/td>\n<td>1<\/td>\n<td>1<\/td>\n<td>CJX2-9511*.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2 class=\"fl-heading\"><span class=\"fl-heading-text\">Especifica\u00e7\u00f5es<\/span><\/h2>\n<table width=\"714\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"122\" \/>\n<col width=\"100\" \/>\n<col width=\"38\" \/>\n<col width=\"45\" \/>\n<col width=\"46\" \/>\n<col width=\"45\" \/>\n<col width=\"47\" \/>\n<col width=\"32\" \/>\n<col width=\"10\" \/>\n<col width=\"46\" \/>\n<col width=\"46\" \/>\n<col width=\"45\" \/>\n<col width=\"44\" \/>\n<col width=\"29\" \/>\n<col width=\"14\" \/><\/colgroup>\n<tbody>\n<tr class=\"firstRow\">\n<td colspan=\"2\" width=\"223\" height=\"37\">N\u00famero do modelo<\/td>\n<td width=\"39\"><\/td>\n<td width=\"46\">CJX2-0911<\/td>\n<td width=\"47\">CJX2-1211<\/td>\n<td width=\"46\">CJX2-1811<\/td>\n<td width=\"47\">CJX2-2511<\/td>\n<td colspan=\"2\" width=\"42\">CJX2-3211<\/td>\n<td width=\"47\">CJX2-4011<\/td>\n<td width=\"47\">CJX2-5011<\/td>\n<td width=\"46\">CJX2-6511<\/td>\n<td width=\"44\">CJX2-8011<\/td>\n<td colspan=\"2\" width=\"43\">CJX2-9511<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"223\" height=\"19\">Carater\u00edsticas do circuito principal<\/td>\n<td width=\"39\"><\/td>\n<td width=\"46\"><\/td>\n<td width=\"47\"><\/td>\n<td width=\"46\"><\/td>\n<td width=\"47\"><\/td>\n<td colspan=\"2\" width=\"42\"><\/td>\n<td width=\"47\"><\/td>\n<td width=\"47\"><\/td>\n<td width=\"46\"><\/td>\n<td width=\"44\"><\/td>\n<td colspan=\"2\" width=\"43\"><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"223\" height=\"19\">N\u00famero do p\u00f3lo<\/td>\n<td colspan=\"13\" width=\"492\">3P\u00f3los<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"223\" height=\"25\">Tens\u00e3o nominal de isolamento (Ui)<\/td>\n<td width=\"39\">V<\/td>\n<td colspan=\"12\" width=\"453\">690<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"223\" height=\"38\">Corrente t\u00e9rmica convencional (th)<br \/>\nCorrente nominal de trabalho AC-1<\/td>\n<td width=\"39\"><\/td>\n<td width=\"46\">20<\/td>\n<td width=\"47\">20<\/td>\n<td width=\"46\">32<\/td>\n<td width=\"47\">40<\/td>\n<td colspan=\"2\" width=\"42\">50<\/td>\n<td width=\"47\">50<\/td>\n<td width=\"47\">60<\/td>\n<td width=\"46\">80<\/td>\n<td width=\"44\">125<\/td>\n<td colspan=\"2\" width=\"43\">125<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\" width=\"123\" height=\"76\">Trabalho classificado<br \/>\ncorrente (Ie)<\/td>\n<td width=\"100\">AC-3,380\/400V<\/td>\n<td width=\"39\">Um<\/td>\n<td width=\"46\">9<\/td>\n<td width=\"47\">12<\/td>\n<td width=\"46\">18<\/td>\n<td width=\"47\">25<\/td>\n<td colspan=\"2\" width=\"42\">32<\/td>\n<td width=\"47\">40<\/td>\n<td width=\"47\">50<\/td>\n<td width=\"46\">65<\/td>\n<td width=\"44\">80<\/td>\n<td colspan=\"2\" width=\"43\">95<\/td>\n<\/tr>\n<tr>\n<td width=\"100\">AC-3,660\/690V<\/td>\n<td width=\"39\">Um<\/td>\n<td width=\"46\">6.6<\/td>\n<td width=\"47\">8.9<\/td>\n<td width=\"46\">12<\/td>\n<td width=\"47\">18<\/td>\n<td colspan=\"2\" width=\"42\">22<\/td>\n<td width=\"47\">34<\/td>\n<td width=\"47\">39<\/td>\n<td width=\"46\">42<\/td>\n<td width=\"44\">49<\/td>\n<td colspan=\"2\" width=\"43\">49<\/td>\n<\/tr>\n<tr>\n<td width=\"100\">AC-4,380\/400V<\/td>\n<td width=\"39\">Um<\/td>\n<td width=\"46\">3.5<\/td>\n<td width=\"47\">5<\/td>\n<td width=\"46\">7.7<\/td>\n<td width=\"47\">8.5<\/td>\n<td colspan=\"2\" width=\"42\">12<\/td>\n<td width=\"47\">18.5<\/td>\n<td width=\"47\">24<\/td>\n<td width=\"46\">28<\/td>\n<td width=\"44\">37<\/td>\n<td colspan=\"2\" width=\"43\">44<\/td>\n<\/tr>\n<tr>\n<td width=\"100\">AC-4,660\/690V<\/td>\n<td width=\"39\">Um<\/td>\n<td width=\"46\">1.5<\/td>\n<td width=\"47\">2<\/td>\n<td width=\"46\">3.8<\/td>\n<td width=\"47\">4.4<\/td>\n<td colspan=\"2\" width=\"42\">7.5<\/td>\n<td width=\"47\">9<\/td>\n<td width=\"47\">12<\/td>\n<td width=\"46\">14<\/td>\n<td width=\"44\">17.3<\/td>\n<td colspan=\"2\" width=\"43\">21.3<\/td>\n<\/tr>\n<tr>\n<td width=\"123\" height=\"19\"><\/td>\n<td width=\"100\">AC-3,220\/240V<\/td>\n<td width=\"39\">KW<\/td>\n<td width=\"46\">2.2<\/td>\n<td width=\"47\">3<\/td>\n<td width=\"46\">4<\/td>\n<td width=\"47\">5.5<\/td>\n<td colspan=\"2\" width=\"42\">7.5<\/td>\n<td width=\"47\">11<\/td>\n<td width=\"47\">15<\/td>\n<td width=\"46\">18.5<\/td>\n<td width=\"44\">22<\/td>\n<td colspan=\"2\" width=\"43\">25<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"6\" width=\"123\" height=\"114\">Trabalho classificado<br \/>\npot\u00eancia(Pe)<\/td>\n<td width=\"100\">AC-3,380\/400V<\/td>\n<td width=\"39\">KW<\/td>\n<td width=\"46\">4<\/td>\n<td width=\"47\">5.5<\/td>\n<td width=\"46\">7.5<\/td>\n<td width=\"47\">11<\/td>\n<td colspan=\"2\" width=\"42\">15<\/td>\n<td width=\"47\">18.5<\/td>\n<td width=\"47\">22<\/td>\n<td width=\"46\">30<\/td>\n<td width=\"44\">37<\/td>\n<td colspan=\"2\" width=\"43\">45<\/td>\n<\/tr>\n<tr>\n<td width=\"100\">AC-3,415\/440V<\/td>\n<td width=\"39\">KW<\/td>\n<td width=\"46\">4<\/td>\n<td width=\"47\">5.5<\/td>\n<td width=\"46\">9<\/td>\n<td width=\"47\">11<\/td>\n<td colspan=\"2\" width=\"42\">15<\/td>\n<td width=\"47\">22<\/td>\n<td width=\"47\">25\/30<\/td>\n<td width=\"46\">37<\/td>\n<td width=\"44\">45<\/td>\n<td colspan=\"2\" width=\"43\">45<\/td>\n<\/tr>\n<tr>\n<td width=\"100\">AC-3,500V<\/td>\n<td width=\"39\">KW<\/td>\n<td width=\"46\">5.5<\/td>\n<td width=\"47\">7.5<\/td>\n<td width=\"46\">10<\/td>\n<td width=\"47\">15<\/td>\n<td colspan=\"2\" width=\"42\">18.5<\/td>\n<td width=\"47\">22<\/td>\n<td width=\"47\">30<\/td>\n<td width=\"46\">37<\/td>\n<td width=\"44\">55<\/td>\n<td colspan=\"2\" width=\"43\">55<\/td>\n<\/tr>\n<tr>\n<td width=\"100\">AC-3,660\/690V<\/td>\n<td width=\"39\">KW<\/td>\n<td width=\"46\">5.5<\/td>\n<td width=\"47\">7.5<\/td>\n<td width=\"46\">10<\/td>\n<td width=\"47\">15<\/td>\n<td colspan=\"2\" width=\"42\">18.5<\/td>\n<td width=\"47\">30<\/td>\n<td width=\"47\">33<\/td>\n<td width=\"46\">37<\/td>\n<td width=\"44\">45<\/td>\n<td colspan=\"2\" width=\"43\">45<\/td>\n<\/tr>\n<tr>\n<td width=\"100\">AC-4,380\/400V<\/td>\n<td width=\"39\">KW<\/td>\n<td width=\"46\">1.5<\/td>\n<td width=\"47\">2.2<\/td>\n<td width=\"46\">3.3<\/td>\n<td width=\"47\">4<\/td>\n<td colspan=\"2\" width=\"42\">5.4<\/td>\n<td width=\"47\">7.5<\/td>\n<td width=\"47\">11<\/td>\n<td width=\"46\">15<\/td>\n<td width=\"44\">18.5<\/td>\n<td colspan=\"2\" width=\"43\">22<\/td>\n<\/tr>\n<tr>\n<td width=\"100\">AC-4,660\/690V<\/td>\n<td width=\"39\">KW<\/td>\n<td width=\"46\">1.1<\/td>\n<td width=\"47\">1.5<\/td>\n<td width=\"46\">3<\/td>\n<td width=\"47\">3.7<\/td>\n<td colspan=\"2\" width=\"42\">5.5<\/td>\n<td width=\"47\">7.5<\/td>\n<td width=\"47\">10<\/td>\n<td width=\"46\">11<\/td>\n<td width=\"44\">15<\/td>\n<td colspan=\"2\" width=\"43\">18.5<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"223\" height=\"38\">Vida mec\u00e2nica<\/td>\n<td width=\"39\">10000<br \/>\ntempos<\/td>\n<td colspan=\"3\" width=\"138\">1200<\/td>\n<td colspan=\"3\" width=\"89\">1000<\/td>\n<td colspan=\"3\" width=\"139\">900<\/td>\n<td colspan=\"3\" width=\"87\">650<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" width=\"123\" height=\"76\">Vida el\u00e9ctrica<\/td>\n<td width=\"100\">AC-3<\/td>\n<td width=\"39\">10000<br \/>\ntempos<\/td>\n<td colspan=\"4\" width=\"185\">110<\/td>\n<td colspan=\"5\" width=\"181\">90<\/td>\n<td colspan=\"3\" width=\"87\">65<\/td>\n<\/tr>\n<tr>\n<td width=\"100\">AC-4<\/td>\n<td width=\"39\">10000<br \/>\ntempos<\/td>\n<td colspan=\"4\" width=\"185\">22<\/td>\n<td colspan=\"2\" width=\"42\">22<\/td>\n<td colspan=\"3\" width=\"139\">17<\/td>\n<td colspan=\"3\" width=\"87\">11<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" width=\"123\" height=\"76\">Funcionamento<br \/>\nfrequ\u00eancia<\/td>\n<td width=\"100\">AC-3<\/td>\n<td width=\"39\">Vezes\/<br \/>\nhora<\/td>\n<td colspan=\"4\" width=\"185\">1200<\/td>\n<td colspan=\"8\" width=\"268\">600<\/td>\n<\/tr>\n<tr>\n<td width=\"100\">AC-4<\/td>\n<td width=\"39\">Vezes\/<br \/>\nhora<\/td>\n<td colspan=\"4\" width=\"185\">300<\/td>\n<td colspan=\"8\" width=\"268\">300<\/td>\n<\/tr>\n<tr>\n<td width=\"123\" height=\"23\">Sem blocos de terminais<\/td>\n<td width=\"100\">2 fios<\/td>\n<td width=\"39\">mm\u00b2<\/td>\n<td colspan=\"3\" width=\"138\">1&#8230;4<\/td>\n<td colspan=\"3\" width=\"89\">1.5&#8230;<\/td>\n<td colspan=\"3\" width=\"139\">2.5&#8230;10<\/td>\n<td colspan=\"3\" width=\"87\">4&#8230;25<\/td>\n<\/tr>\n<tr>\n<td width=\"123\" height=\"19\">Bin\u00e1rio de aperto<\/td>\n<td width=\"100\">N-m<\/td>\n<td width=\"39\"><\/td>\n<td colspan=\"3\" width=\"138\">1.2<\/td>\n<td colspan=\"3\" width=\"89\">1.8<\/td>\n<td colspan=\"3\" width=\"139\">5<\/td>\n<td colspan=\"3\" width=\"87\">9<\/td>\n<\/tr>\n<tr>\n<td width=\"123\" height=\"19\">Bobina<\/td>\n<td colspan=\"14\" width=\"592\"><\/td>\n<\/tr>\n<tr>\n<td width=\"123\" height=\"19\"><\/td>\n<td width=\"100\">50\/60Hz<\/td>\n<td width=\"39\">V<\/td>\n<td colspan=\"12\" width=\"453\">24\u300136\u300148\u3001110\u3001127\u3001220\/230\u3001240\u3001380\/400\u3001415\u3001440<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" width=\"123\" height=\"38\">Permitir o controlo<br \/>\ntens\u00e3o do circuito (Us)<\/td>\n<td width=\"100\">Trabalho<\/td>\n<td width=\"39\">V<\/td>\n<td colspan=\"12\" width=\"453\">O \u00e2ngulo de inclina\u00e7\u00e3o da instala\u00e7\u00e3o \u00e9 de \u00b122,5\u00b0 :85%~110%Us\uff1b O \u00e2ngulo de inclina\u00e7\u00e3o da instala\u00e7\u00e3o \u00e9 de\u00b15\u00b0\uff1a 70%~120%<\/td>\n<\/tr>\n<tr>\n<td width=\"100\">Liberta\u00e7\u00e3o<\/td>\n<td width=\"39\">V<\/td>\n<td colspan=\"12\" width=\"453\">O \u00e2ngulo de inclina\u00e7\u00e3o da instala\u00e7\u00e3o \u00e9 de \u00b122,5\u00b0, 20%~75%US\uff1bO \u00e2ngulo de inclina\u00e7\u00e3o da instala\u00e7\u00e3o \u00e9 de\u00b15\u00b0\uff1a 20%~65%<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" width=\"123\" height=\"57\">Pot\u00eancia da bobina<br \/>\nconsumo<\/td>\n<td width=\"100\">Atua\u00e7\u00e3o<\/td>\n<td width=\"39\">VA<\/td>\n<td colspan=\"3\" width=\"138\">60<\/td>\n<td colspan=\"3\" width=\"89\">70<\/td>\n<td colspan=\"3\" width=\"139\">200<\/td>\n<td colspan=\"3\" width=\"87\">200<\/td>\n<\/tr>\n<tr>\n<td width=\"100\">Manter<\/td>\n<td width=\"39\">VA<\/td>\n<td colspan=\"3\" width=\"138\">6-9.5<\/td>\n<td colspan=\"3\" width=\"89\">6-9.5<\/td>\n<td colspan=\"3\" width=\"139\">15-20<\/td>\n<td colspan=\"3\" width=\"87\">15-20<\/td>\n<\/tr>\n<tr>\n<td width=\"100\">Consumo<\/td>\n<td width=\"39\">W<\/td>\n<td colspan=\"3\" width=\"138\">1-3<\/td>\n<td colspan=\"3\" width=\"89\">1-3<\/td>\n<td colspan=\"3\" width=\"139\">6-10<\/td>\n<td colspan=\"3\" width=\"87\">6-10<\/td>\n<\/tr>\n<tr>\n<td width=\"123\" height=\"19\">Contacto auxiliar<\/td>\n<td colspan=\"14\" width=\"592\"><\/td>\n<\/tr>\n<tr>\n<td width=\"123\" height=\"19\">Especifica\u00e7\u00f5es de contacto<\/td>\n<td width=\"100\"><\/td>\n<td width=\"39\">Um<\/td>\n<td colspan=\"12\" width=\"453\">11<\/td>\n<\/tr>\n<tr>\n<td width=\"123\" height=\"38\">T\u00e9rmica convencional<br \/>\natual(th)<\/td>\n<td width=\"100\"><\/td>\n<td width=\"39\">Um<\/td>\n<td colspan=\"12\" width=\"453\">10<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" width=\"123\" height=\"38\">Funcionamento nominal<br \/>\ntens\u00e3o(Ue)<\/td>\n<td width=\"100\">AC<\/td>\n<td width=\"39\">V<\/td>\n<td colspan=\"12\" width=\"453\">380<\/td>\n<\/tr>\n<tr>\n<td width=\"100\">DC<\/td>\n<td width=\"39\">V<\/td>\n<td colspan=\"12\" width=\"453\">220<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" width=\"123\" height=\"38\">Capacidade nominal de controlo<\/td>\n<td width=\"100\">AC-15<\/td>\n<td width=\"39\">VA<\/td>\n<td colspan=\"12\" width=\"453\">360<\/td>\n<\/tr>\n<tr>\n<td width=\"100\">DC-13<\/td>\n<td width=\"39\">W<\/td>\n<td colspan=\"12\" width=\"453\">33<\/td>\n<\/tr>\n<tr>\n<td width=\"123\" height=\"20\">CERTIFICADO<\/td>\n<td colspan=\"14\" width=\"592\">CE<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2 class=\"fl-heading\">Dimens\u00e3o<\/h2>\n<table border=\"1\">\n<tbody>\n<tr>\n<td colspan=\"5\"><a href=\"https:\/\/test.viox.com\/pt\/?attachment_id=5515\" rel=\"attachment wp-att-5515\"><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-5515\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/cjx2-product-description8.webp\" alt=\"\" width=\"1200\" height=\"501\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/cjx2-product-description8.webp 1200w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/cjx2-product-description8-300x125.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/cjx2-product-description8-1024x428.webp 1024w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/cjx2-product-description8-768x321.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/cjx2-product-description8-600x251.webp 600w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/a><!-- PIC --><\/td>\n<\/tr>\n<tr>\n<th>Tipo<\/th>\n<th>M\u00e1ximo<\/th>\n<th>Cmax<\/th>\n<th>C1<\/th>\n<th>C2<\/th>\n<\/tr>\n<tr>\n<td>CJX2-09,12<\/td>\n<td>47<\/td>\n<td>82<\/td>\n<td>115<\/td>\n<td>134<\/td>\n<\/tr>\n<tr>\n<td>CJX2-18<\/td>\n<td>47<\/td>\n<td>87<\/td>\n<td>120<\/td>\n<td>139<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"1\">\n<tbody>\n<tr>\n<td colspan=\"5\"><a href=\"https:\/\/test.viox.com\/pt\/?attachment_id=5516\" rel=\"attachment wp-att-5516\"><img decoding=\"async\" class=\"alignnone size-full wp-image-5516\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/cjx2-product-description10.webp\" alt=\"\" width=\"1200\" height=\"500\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/cjx2-product-description10.webp 1200w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/cjx2-product-description10-300x125.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/cjx2-product-description10-1024x427.webp 1024w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/cjx2-product-description10-768x320.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/cjx2-product-description10-600x250.webp 600w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/a><!-- \u56fe\u7247\u4f4d\u7f6e --><\/td>\n<\/tr>\n<tr>\n<th>Tipo<\/th>\n<th>M\u00e1ximo<\/th>\n<th>Cmax<\/th>\n<th>C1<\/th>\n<th>C2<\/th>\n<\/tr>\n<tr>\n<td>CJX2-25<\/td>\n<td>59<\/td>\n<td>97<\/td>\n<td>130<\/td>\n<td>149<\/td>\n<\/tr>\n<tr>\n<td>CJX2-32<\/td>\n<td>59<\/td>\n<td>102<\/td>\n<td>135<\/td>\n<td>154<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"1\">\n<tbody>\n<tr>\n<td colspan=\"5\"><a href=\"https:\/\/test.viox.com\/pt\/?attachment_id=5514\" rel=\"attachment wp-att-5514\"><img decoding=\"async\" class=\"alignnone size-full wp-image-5514\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/cjx2i-product-description8-1.webp\" alt=\"\" width=\"1200\" height=\"544\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/cjx2i-product-description8-1.webp 1200w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/cjx2i-product-description8-1-300x136.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/cjx2i-product-description8-1-1024x464.webp 1024w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/cjx2i-product-description8-1-768x348.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/cjx2i-product-description8-1-600x272.webp 600w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/a><!-- \u56fe\u7247\u4f4d\u7f6e --><\/td>\n<\/tr>\n<tr>\n<th>Tipo<\/th>\n<th>M\u00e1ximo<\/th>\n<th>Cmax<\/th>\n<th>C1<\/th>\n<th>C2<\/th>\n<\/tr>\n<tr>\n<td>CJX2-40,50,65<\/td>\n<td>79<\/td>\n<td>116<\/td>\n<td>149<\/td>\n<td>168<\/td>\n<\/tr>\n<tr>\n<td>CJX2-80,95<\/td>\n<td>87<\/td>\n<td>127<\/td>\n<td>160<\/td>\n<td>179<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2 class=\"fl-heading\"><span class=\"fl-heading-text\">Especifica\u00e7\u00f5es<\/span><\/h2>\n<table border=\"1\">\n<tbody>\n<tr>\n<th>Item<\/th>\n<th>Dados<\/th>\n<\/tr>\n<tr>\n<td>Temperatura ambiente<\/td>\n<td>-5\u00b0C~+40\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Altitude<\/td>\n<td>\u22642000m<\/td>\n<\/tr>\n<tr>\n<td>Humidade relativa<\/td>\n<td>A temperatura m\u00e1xima de 40 graus, a humidade relativa do ar n\u00e3o excede 50%, a uma temperatura mais baixa pode permitir uma humidade relativa mais elevada, se a humidade mudar em resultado do gel ocasional gerado, deve elimin\u00e1-lo.<\/td>\n<\/tr>\n<tr>\n<td>N\u00edvel de polui\u00e7\u00e3o<\/td>\n<td>3<\/td>\n<\/tr>\n<tr>\n<td>Categoria de instala\u00e7\u00e3o<\/td>\n<td>III<\/td>\n<\/tr>\n<tr>\n<td>Posi\u00e7\u00e3o de instala\u00e7\u00e3o<\/td>\n<td>O grau de instala\u00e7\u00e3o da inclina\u00e7\u00e3o e do plano vertical n\u00e3o deve exceder \u00b122,5\u00b0, deve ser instalado no local sem impacto significativo de agita\u00e7\u00e3o e vibra\u00e7\u00e3o<\/td>\n<\/tr>\n<tr>\n<td>Instala\u00e7\u00e3o<\/td>\n<td>A instala\u00e7\u00e3o de parafusos de fixa\u00e7\u00e3o pode ser utilizada, o contactor CJX1-9~38 tamb\u00e9m pode ser instalado numa calha DIN normalizada de 35 mm.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>","protected":false},"excerpt":{"rendered":"<div class=\"msg-content MuiBox-root css-0\">\n<div class=\"break-words\">\n<p>O contactor CA da s\u00e9rie CJX2 da VIOX oferece um controlo de pot\u00eancia vers\u00e1til para aplica\u00e7\u00f5es el\u00e9ctricas at\u00e9 660V CA a 50\/60Hz. Este dispositivo robusto lida com correntes at\u00e9 95A, abrindo\/desligando circuitos e controlando motores CA de forma eficiente. Em conformidade com a norma IEC 60947-4-1, apresenta uma versatilidade excecional, transformando-se em unidades especializadas quando combinado com componentes auxiliares. A s\u00e9rie CJX2 oferece op\u00e7\u00f5es flex\u00edveis de tens\u00e3o da bobina e pode funcionar como um arrancador eletromagn\u00e9tico quando emparelhado com um rel\u00e9 t\u00e9rmico. Com o seu design conect\u00e1vel, f\u00e1cil montagem em calha DIN e carater\u00edsticas de prote\u00e7\u00e3o abrangentes, este contactor proporciona um desempenho fi\u00e1vel para controlos de motores, sistemas de ilumina\u00e7\u00e3o e v\u00e1rias necessidades de distribui\u00e7\u00e3o de energia industrial.<\/p>\n<\/div>\n<\/div>","protected":false},"featured_media":5526,"comment_status":"closed","ping_status":"closed","template":"","meta":{"inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[],"product_cat":[116,128],"product_tag":[],"class_list":{"0":"post-5525","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-low-voltage-protection-devices","7":"product_cat-ac-contactor","8":"desktop-align-left","9":"tablet-align-left","10":"mobile-align-left","12":"first","13":"instock","14":"shipping-taxable","15":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/test.viox.com\/pt\/wp-json\/wp\/v2\/product\/5525","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/test.viox.com\/pt\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/test.viox.com\/pt\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/test.viox.com\/pt\/wp-json\/wp\/v2\/comments?post=5525"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/test.viox.com\/pt\/wp-json\/wp\/v2\/media\/5526"}],"wp:attachment":[{"href":"https:\/\/test.viox.com\/pt\/wp-json\/wp\/v2\/media?parent=5525"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/test.viox.com\/pt\/wp-json\/wp\/v2\/product_brand?post=5525"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/test.viox.com\/pt\/wp-json\/wp\/v2\/product_cat?post=5525"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/test.viox.com\/pt\/wp-json\/wp\/v2\/product_tag?post=5525"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}