{"id":14354,"date":"2025-03-20T12:21:43","date_gmt":"2025-03-20T04:21:43","guid":{"rendered":"https:\/\/viox.com\/?post_type=product&#038;p=14354"},"modified":"2025-03-20T12:21:43","modified_gmt":"2025-03-20T04:21:43","slug":"viox-fct18-q-single-function-time-relay","status":"publish","type":"product","link":"https:\/\/test.viox.com\/pt\/produto\/viox-fct18-q-single-function-time-relay\/","title":{"rendered":"Rel\u00e9 de tempo de fun\u00e7\u00e3o \u00fanica VIOX FCT18-Q"},"content":{"rendered":"<div class=\"product-intro\">\n<h2>Introdu\u00e7\u00e3o<\/h2>\n<p>O FCT18-Q \u00e9 um rel\u00e9 de tempo de fun\u00e7\u00e3o \u00fanica de alta precis\u00e3o, de n\u00edvel industrial, concebido para aplica\u00e7\u00f5es que requerem uma funcionalidade fi\u00e1vel de temporiza\u00e7\u00e3o com atraso OFF. Com as suas defini\u00e7\u00f5es vers\u00e1teis de intervalo de tempo, ampla compatibilidade com a fonte de alimenta\u00e7\u00e3o e constru\u00e7\u00e3o robusta, o FCT18-Q oferece um desempenho excecional para sistemas de automa\u00e7\u00e3o, pain\u00e9is de controlo industrial e maquinaria que requer um controlo de temporiza\u00e7\u00e3o preciso.<\/p>\n<p>Este rel\u00e9 mont\u00e1vel em calha DIN possui uma funcionalidade tripla de atraso de desativa\u00e7\u00e3o com disparo de borda ascendente, tornando-o ideal para opera\u00e7\u00f5es de sequencia\u00e7\u00e3o, procedimentos de encerramento de m\u00e1quinas, ciclos de arrefecimento e outras aplica\u00e7\u00f5es de temporiza\u00e7\u00e3o cr\u00edticas em que a continuidade e a precis\u00e3o do sinal s\u00e3o essenciais.<\/p>\n<h2>Principais carater\u00edsticas e vantagens<\/h2>\n<ul>\n<li><strong>Amplo intervalo de tempo<\/strong>: Ajust\u00e1vel de 0,1 segundos a 100 dias, proporcionando flexibilidade para praticamente qualquer aplica\u00e7\u00e3o de temporiza\u00e7\u00e3o industrial<\/li>\n<li><strong>Fonte de alimenta\u00e7\u00e3o universal<\/strong>: Compat\u00edvel com fontes de alimenta\u00e7\u00e3o de 12 a 240 VAC\/DC, eliminando a necessidade de m\u00faltiplas variantes de rel\u00e9s<\/li>\n<li><strong>Alta precis\u00e3o<\/strong>: Erro de tempo inferior a 0,5% e desvio de tempo de apenas 0,1%, garantindo um funcionamento fi\u00e1vel e consistente<\/li>\n<li><strong>Design de f\u00e1cil utiliza\u00e7\u00e3o<\/strong>: Configura\u00e7\u00e3o f\u00e1cil com diagramas de cablagem claros impressos diretamente na caixa do produto<\/li>\n<li><strong>Forte capacidade anti-interfer\u00eancia<\/strong>: Concebido para manter um desempenho est\u00e1vel em ambientes eletricamente ruidosos<\/li>\n<li><strong>Op\u00e7\u00f5es de sinal de controlo duplo<\/strong>: Dispon\u00edvel nas configura\u00e7\u00f5es NPN e PNP para corresponder aos requisitos do seu sistema de controlo<\/li>\n<li><strong>LEDs indicadores<\/strong>: LED verde para o estado da alimenta\u00e7\u00e3o e LED vermelho para a ativa\u00e7\u00e3o do rel\u00e9 para uma monitoriza\u00e7\u00e3o visual clara<\/li>\n<li><strong>Dimens\u00f5es compactas<\/strong>: Design economizador de espa\u00e7o de 90 mm \u00d7 18 mm \u00d7 64 mm para uma utiliza\u00e7\u00e3o eficiente do painel<\/li>\n<li><strong>Durabilidade de n\u00edvel industrial<\/strong>: Gama de temperaturas de funcionamento de -20\u00b0C a +85\u00b0C com \u00edndice de prote\u00e7\u00e3o IP20<\/li>\n<\/ul>\n<h2>Compreender a fun\u00e7\u00e3o de atraso de desativa\u00e7\u00e3o<\/h2>\n<p>O FCT18-Q opera com a funcionalidade de triplo atraso OFF (disparo de borda ascendente). Durante o per\u00edodo de processamento do atraso, o sinal ser\u00e1 considerado inv\u00e1lido. O funcionamento \u00e9 o seguinte:<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-14355\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-Q-Single-Function-Time-Relay-timing-function.webp\" alt=\"VIOX FCT18-Q Single Function Time Relay timing function\" width=\"810\" height=\"292\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-Q-Single-Function-Time-Relay-timing-function.webp 810w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-Q-Single-Function-Time-Relay-timing-function-300x108.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-Q-Single-Function-Time-Relay-timing-function-768x277.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-Q-Single-Function-Time-Relay-timing-function-18x6.webp 18w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-Q-Single-Function-Time-Relay-timing-function-600x216.webp 600w\" sizes=\"(max-width: 810px) 100vw, 810px\" \/><\/p>\n<ol>\n<li>Quando o sinal de entrada (Un) \u00e9 aplicado, a sa\u00edda do rel\u00e9 (R) permanece ativa<\/li>\n<li>A fun\u00e7\u00e3o de temporiza\u00e7\u00e3o \u00e9 acionada pela borda ascendente do sinal de entrada (S)<\/li>\n<li>Quando o sinal de entrada \u00e9 removido, o rel\u00e9 mant\u00e9m o seu estado durante o per\u00edodo de tempo pr\u00e9-definido (T1+T2)<\/li>\n<li>Ap\u00f3s o per\u00edodo de atraso expirar, o rel\u00e9 volta ao seu estado original<\/li>\n<\/ol>\n<p>Esta fun\u00e7\u00e3o de temporiza\u00e7\u00e3o \u00e9 particularmente \u00fatil para aplica\u00e7\u00f5es em que o equipamento precisa de continuar a funcionar durante um per\u00edodo espec\u00edfico depois de o sinal de disparo ter sido removido, como por exemplo, ventoinhas que continuam a funcionar depois de uma m\u00e1quina ser desligada para permitir o arrefecimento.<\/p>\n<h2>Op\u00e7\u00f5es de defini\u00e7\u00e3o da hora<\/h2>\n<p>O FCT18-Q oferece uma gama excecionalmente ampla de defini\u00e7\u00f5es de tempo atrav\u00e9s do seu sistema de sele\u00e7\u00e3o intuitivo. Os intervalos de tempo dispon\u00edveis incluem:<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-14356\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-Q-Single-Function-Time-Relay-time-setting.webp\" alt=\"VIOX FCT18-Q Single Function Time Relay time setting\" width=\"820\" height=\"312\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-Q-Single-Function-Time-Relay-time-setting.webp 820w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-Q-Single-Function-Time-Relay-time-setting-300x114.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-Q-Single-Function-Time-Relay-time-setting-768x292.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-Q-Single-Function-Time-Relay-time-setting-18x7.webp 18w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-Q-Single-Function-Time-Relay-time-setting-600x228.webp 600w\" sizes=\"(max-width: 820px) 100vw, 820px\" \/><\/p>\n<ul>\n<li>0,1-1 segundo<\/li>\n<li>1-10 segundos<\/li>\n<li>0,1-1 minuto<\/li>\n<li>1-10 minutos<\/li>\n<li>0,1-1 hora<\/li>\n<li>1-10 horas<\/li>\n<li>0,1-1 dia<\/li>\n<li>1-10 dias<\/li>\n<li>3-30 dias<\/li>\n<li>10-100 dias<\/li>\n<\/ul>\n<p>Cada gama \u00e9 facilmente selecionada utilizando os mostradores rotativos claramente marcados na frente da unidade, permitindo um controlo preciso dos seus requisitos de temporiza\u00e7\u00e3o, desde intervalos de sub-segundos a dura\u00e7\u00f5es de v\u00e1rios meses.<\/p>\n<h2>Flexibilidade na defini\u00e7\u00e3o do r\u00e1cio<\/h2>\n<p>O FCT18-Q possui capacidades de ajuste fino com o seu seletor de defini\u00e7\u00e3o de r\u00e1cio, permitindo-lhe selecionar a percentagem exacta do intervalo de tempo m\u00e1ximo. As defini\u00e7\u00f5es de r\u00e1cio dispon\u00edveis incluem:<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-14357\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-Q-Single-Function-Time-Relay-ratio-setting.webp\" alt=\"VIOX FCT18-Q Single Function Time Relay ratio setting\" width=\"956\" height=\"262\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-Q-Single-Function-Time-Relay-ratio-setting.webp 956w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-Q-Single-Function-Time-Relay-ratio-setting-300x82.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-Q-Single-Function-Time-Relay-ratio-setting-768x210.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-Q-Single-Function-Time-Relay-ratio-setting-18x5.webp 18w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-Q-Single-Function-Time-Relay-ratio-setting-600x164.webp 600w\" sizes=\"(max-width: 956px) 100vw, 956px\" \/><\/p>\n<table>\n<thead>\n<tr>\n<th>Defini\u00e7\u00f5es de r\u00e1cio<\/th>\n<th><\/th>\n<th><\/th>\n<th><\/th>\n<th><\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>10%<\/td>\n<td>15%<\/td>\n<td>20%<\/td>\n<td>25%<\/td>\n<td>30%<\/td>\n<\/tr>\n<tr>\n<td>35%<\/td>\n<td>40%<\/td>\n<td>45%<\/td>\n<td>50%<\/td>\n<td>55%<\/td>\n<\/tr>\n<tr>\n<td>60%<\/td>\n<td>65%<\/td>\n<td>70%<\/td>\n<td>75%<\/td>\n<td>80%<\/td>\n<\/tr>\n<tr>\n<td>85%<\/td>\n<td>90%<\/td>\n<td>95%<\/td>\n<td>100%<\/td>\n<td><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Este ajuste de precis\u00e3o permite-lhe definir exatamente os requisitos de temporiza\u00e7\u00e3o que a sua aplica\u00e7\u00e3o exige sem comprometer a precis\u00e3o.<\/p>\n<h2>Op\u00e7\u00f5es de cablagem<\/h2>\n<p>O FCT18-Q suporta configura\u00e7\u00f5es de sinal de controlo NPN e PNP, tornando-o compat\u00edvel com uma vasta gama de sistemas de controlo industrial:<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-14358\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-Q-Single-Function-Time-Relay-wiring.webp\" alt=\"VIOX FCT18-Q Single Function Time Relay wiring\" width=\"412\" height=\"380\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-Q-Single-Function-Time-Relay-wiring.webp 412w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-Q-Single-Function-Time-Relay-wiring-300x277.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-Q-Single-Function-Time-Relay-wiring-13x12.webp 13w\" sizes=\"(max-width: 412px) 100vw, 412px\" \/><\/p>\n<h3>Configura\u00e7\u00e3o NPN<\/h3>\n<ul>\n<li>Un: Entrada da fonte de alimenta\u00e7\u00e3o<\/li>\n<li>S: Entrada do sinal de controlo<\/li>\n<li>OA1: Sa\u00edda (DC+ \/ AC L)<\/li>\n<li>OA2: Sa\u00edda (DC- \/ AC N)<\/li>\n<li>Terminais: 11, 12, 14, 21, 22, 24 para contactos de rel\u00e9<\/li>\n<\/ul>\n<h3>Configura\u00e7\u00e3o PNP<\/h3>\n<ul>\n<li>Un: Entrada da fonte de alimenta\u00e7\u00e3o<\/li>\n<li>S: Entrada do sinal de controlo<\/li>\n<li>OA1: Sa\u00edda (DC+ \/ AC L)<\/li>\n<li>OA2: Sa\u00edda (DC- \/ AC N)<\/li>\n<li>Terminais: 11, 12, 14, 21, 22, 24 para contactos de rel\u00e9<\/li>\n<\/ul>\n<h2>Especifica\u00e7\u00f5es t\u00e9cnicas<\/h2>\n<table>\n<thead>\n<tr>\n<th>Par\u00e2metro<\/th>\n<th>Especifica\u00e7\u00e3o<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Modelo<\/td>\n<td>FCT18-Q<\/td>\n<\/tr>\n<tr>\n<td>Fun\u00e7\u00e3o<\/td>\n<td>Atraso triplo de desativa\u00e7\u00e3o<\/td>\n<\/tr>\n<tr>\n<td>Terminal de entrada<\/td>\n<td>A1-A2<\/td>\n<\/tr>\n<tr>\n<td>Gama de tens\u00f5es<\/td>\n<td>AC 230V \/ DC24V \/ AC\/DC 12-240V<\/td>\n<\/tr>\n<tr>\n<td>Consumo De Pot\u00eancia<\/td>\n<td>AC 3,5VA\/ DC 2,0W<\/td>\n<\/tr>\n<tr>\n<td>Toler\u00e2ncia de tens\u00e3o<\/td>\n<td>-15% ~ +10%<\/td>\n<\/tr>\n<tr>\n<td>Indica\u00e7\u00e3o de alimenta\u00e7\u00e3o<\/td>\n<td>LED verde<\/td>\n<\/tr>\n<tr>\n<td>Indica\u00e7\u00e3o do rel\u00e9<\/td>\n<td>LED vermelho<\/td>\n<\/tr>\n<tr>\n<td>Intervalos de tempo<\/td>\n<td>0,1s-100dias<\/td>\n<\/tr>\n<tr>\n<td>Defini\u00e7\u00e3o da hora<\/td>\n<td>Bot\u00e3o<\/td>\n<\/tr>\n<tr>\n<td>Desvio de tempo<\/td>\n<td>0.1%<\/td>\n<\/tr>\n<tr>\n<td>Precis\u00e3o da repeti\u00e7\u00e3o<\/td>\n<td>0.5%<\/td>\n<\/tr>\n<tr>\n<td>Coeficiente de temperatura<\/td>\n<td>0,05%\/\u00b0C, a=20\u00b0C (0,05%\/\u00b0F, =68\u00b0F)<\/td>\n<\/tr>\n<tr>\n<td>Contacto de sa\u00edda<\/td>\n<td>1*SPDT (FCT18-Q1) ou 2*SPDT (FCT18-Q2)<\/td>\n<\/tr>\n<tr>\n<td>Corrente Nominal<\/td>\n<td>1*16A (FCT18-Q1) ou 2*16A (FCT18-Q2)<\/td>\n<\/tr>\n<tr>\n<td>Vida mec\u00e2nica<\/td>\n<td>1*10^7<\/td>\n<\/tr>\n<tr>\n<td>Vida el\u00e9ctrica<\/td>\n<td>1*10^5<\/td>\n<\/tr>\n<tr>\n<td>Temperatura ambiente<\/td>\n<td>-20 ... +60 \u00b0C \/ -40 ... +85 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Montagem<\/td>\n<td>Calha DIN EN\/IEC 60715<\/td>\n<\/tr>\n<tr>\n<td>Classifica\u00e7\u00e3o IP<\/td>\n<td>IP20<\/td>\n<\/tr>\n<tr>\n<td>Comprimento de decapagem<\/td>\n<td>7mm (0.28in)<\/td>\n<\/tr>\n<tr>\n<td>Altitude instalada<\/td>\n<td>\u22642200m<\/td>\n<\/tr>\n<tr>\n<td>N\u00edvel de polui\u00e7\u00e3o<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td>Tamanho m\u00e1ximo do cabo<\/td>\n<td>AWG13-20 0,4N-m<\/td>\n<\/tr>\n<tr>\n<td>Dimens\u00e3o<\/td>\n<td>90mm*18mm*64mm<\/td>\n<\/tr>\n<tr>\n<td>Peso<\/td>\n<td>cerca de 90g<\/td>\n<\/tr>\n<tr>\n<td>Normas<\/td>\n<td>GB\/T 14048.5, IEC60947-5-1, EN61812-1<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Guia de sele\u00e7\u00e3o de modelos<\/h2>\n<p>O sistema de designa\u00e7\u00e3o do modelo FCT18-Q segue este formato:<\/p>\n<p><strong>FCT18-Q 1 W N<\/strong><\/p>\n<p>Onde:<\/p>\n<ol>\n<li><strong>Fun\u00e7\u00e3o (Posi\u00e7\u00e3o 1)<\/strong>: Q - Atraso triplo de desativa\u00e7\u00e3o<\/li>\n<li><strong>Tipo de sa\u00edda (posi\u00e7\u00e3o 2)<\/strong>: 1 - 1 contacto COI \/ 2 - 2 contactos COI<\/li>\n<li><strong>Tens\u00e3o de alimenta\u00e7\u00e3o (posi\u00e7\u00e3o 3)<\/strong>: A - AC230V \/ D - DC24V \/ W - AC\/DC12-240V<\/li>\n<li><strong>Sinal de controlo (posi\u00e7\u00e3o 4)<\/strong>: N - NPN \/ P - PNP<\/li>\n<\/ol>\n<p>Por exemplo, FCT18-Q1WN indica um rel\u00e9 de tempo de fun\u00e7\u00e3o \u00fanica com fun\u00e7\u00e3o tripla de atraso de desativa\u00e7\u00e3o, sa\u00edda de contacto 1CO, tens\u00e3o de alimenta\u00e7\u00e3o AC\/DC12-240V e sinal de controlo NPN.<\/p>\n<h2>Dimens\u00e3o<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-14359\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-Q-Single-Function-Time-Relay-dimension.webp\" alt=\"VIOX FCT18-Q Single Function Time Relay dimension\" width=\"410\" height=\"372\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-Q-Single-Function-Time-Relay-dimension.webp 410w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-Q-Single-Function-Time-Relay-dimension-300x272.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-Q-Single-Function-Time-Relay-dimension-13x12.webp 13w\" sizes=\"(max-width: 410px) 100vw, 410px\" \/><\/p>\n<h2>Aplica\u00e7\u00f5es<\/h2>\n<p>O rel\u00e9 de tempo de fun\u00e7\u00e3o \u00fanica FCT18-Q \u00e9 ideal para in\u00fameras aplica\u00e7\u00f5es industriais e de automa\u00e7\u00e3o:<\/p>\n<ul>\n<li><strong>Equipamento de fabrico<\/strong>: Controlo de opera\u00e7\u00f5es sequenciais em linhas de montagem<\/li>\n<li><strong>Sistemas HVAC<\/strong>: Temporiza\u00e7\u00e3o do ventilador para sistemas de ventila\u00e7\u00e3o<\/li>\n<li><strong>Controlo da bomba<\/strong>: Paragem retardada dos sistemas de circula\u00e7\u00e3o de \u00e1gua<\/li>\n<li><strong>Processos industriais<\/strong>: Opera\u00e7\u00f5es temporizadas de dosagem de produtos qu\u00edmicos ou de manuseamento de materiais<\/li>\n<li><strong>Controlo da ilumina\u00e7\u00e3o<\/strong>: Temporizadores de escadas e cen\u00e1rios de ilumina\u00e7\u00e3o com atraso de desligamento<\/li>\n<li><strong>Sistemas de seguran\u00e7a<\/strong>: Sequ\u00eancias de ativa\u00e7\u00e3o ou desativa\u00e7\u00e3o retardadas<\/li>\n<li><strong>Equipamento agr\u00edcola<\/strong>: Controlos de temporiza\u00e7\u00e3o do sistema de irriga\u00e7\u00e3o<\/li>\n<li><strong>Gest\u00e3o da energia<\/strong>: Corte de carga de pico com religa\u00e7\u00e3o temporizada<\/li>\n<li><strong>Seguran\u00e7a das m\u00e1quinas<\/strong>: Assegurar per\u00edodos de arrefecimento adequados antes da manuten\u00e7\u00e3o<\/li>\n<li><strong>Sistemas de transporte<\/strong>: Coordena\u00e7\u00e3o do tempo de transporte dos produtos<\/li>\n<\/ul>\n<h2>Diretrizes de instala\u00e7\u00e3o<\/h2>\n<p>Para um desempenho e fiabilidade ideais, recomendamos que siga estas diretrizes de instala\u00e7\u00e3o:<\/p>\n<ol>\n<li>Montar o FCT18-Q numa calha DIN normalizada de 35 mm na posi\u00e7\u00e3o vertical<\/li>\n<li>Assegurar uma ventila\u00e7\u00e3o adequada \u00e0 volta do dispositivo, especialmente em ambientes com temperaturas elevadas<\/li>\n<li>Manter uma dist\u00e2ncia m\u00ednima de 5 mm entre dispositivos adjacentes para evitar o sobreaquecimento<\/li>\n<li>Utilize o calibre de fio adequado (AWG13-20) e mantenha o comprimento de decapagem recomendado de 7 mm<\/li>\n<li>Verifique se a tens\u00e3o de alimenta\u00e7\u00e3o corresponde \u00e0 classifica\u00e7\u00e3o do dispositivo antes de o ligar<\/li>\n<li>Siga o diagrama de cablagem na parte lateral do produto para uma liga\u00e7\u00e3o correta<\/li>\n<li>Selecionar o intervalo de tempo e a defini\u00e7\u00e3o do r\u00e1cio adequados antes da opera\u00e7\u00e3o<\/li>\n<li>Manter afastado de fontes de fortes interfer\u00eancias electromagn\u00e9ticas<\/li>\n<li>Instalar em ambientes com n\u00edvel de polui\u00e7\u00e3o 2 ou superior<\/li>\n<li>N\u00e3o exceder a altitude m\u00e1xima de instala\u00e7\u00e3o de 2200m<\/li>\n<\/ol>\n<h2>Manuten\u00e7\u00e3o e resolu\u00e7\u00e3o de problemas<\/h2>\n<p>O FCT18-Q foi concebido para uma manuten\u00e7\u00e3o m\u00ednima, mas recomenda-se a realiza\u00e7\u00e3o de verifica\u00e7\u00f5es peri\u00f3dicas:<\/p>\n<ul>\n<li>Verificar se todas as liga\u00e7\u00f5es permanecem apertadas e sem corros\u00e3o<\/li>\n<li>Verifique se o dispositivo est\u00e1 isento de p\u00f3 e detritos que possam afetar o arrefecimento<\/li>\n<li>Confirmar se os indicadores LED funcionam corretamente<\/li>\n<li>Testar periodicamente a fun\u00e7\u00e3o de temporiza\u00e7\u00e3o para garantir uma precis\u00e3o cont\u00ednua<\/li>\n<li>Substituir a unidade se os limites do ciclo de vida mec\u00e2nico ou el\u00e9trico se aproximarem<\/li>\n<\/ul>\n<p>Passos comuns para a resolu\u00e7\u00e3o de problemas:<\/p>\n<ol>\n<li><strong>Indica\u00e7\u00e3o de falta de energia<\/strong>: Verificar as liga\u00e7\u00f5es de alimenta\u00e7\u00e3o de entrada e o n\u00edvel de tens\u00e3o<\/li>\n<li><strong>Temporiza\u00e7\u00e3o irregular<\/strong>: Verificar se o ambiente est\u00e1 isento de ru\u00eddo el\u00e9trico excessivo<\/li>\n<li><strong>O rel\u00e9 n\u00e3o est\u00e1 a ser ativado<\/strong>: Verificar as liga\u00e7\u00f5es e a polaridade do sinal de controlo<\/li>\n<li><strong>Cronometragem imprecisa<\/strong>: Confirmar se as defini\u00e7\u00f5es do intervalo de tempo e do r\u00e1cio est\u00e3o corretamente configuradas<\/li>\n<li><strong>Sobreaquecimento<\/strong>: Assegurar um espa\u00e7o e uma ventila\u00e7\u00e3o adequados \u00e0 volta do aparelho<\/li>\n<\/ol>\n<h2>Vantagens em rela\u00e7\u00e3o aos produtos concorrentes<\/h2>\n<p>O FCT18-Q oferece v\u00e1rias vantagens distintas em rela\u00e7\u00e3o a rel\u00e9s de temporiza\u00e7\u00e3o semelhantes no mercado:<\/p>\n<ul>\n<li><strong>Intervalo de tempo mais alargado<\/strong>: Muitos produtos concorrentes oferecem apenas de segundos a dias, enquanto o FCT18-Q vai de 0,1 segundos a 100 dias<\/li>\n<li><strong>Maior precis\u00e3o<\/strong>: Com um erro de tempo inferior a 0,5% e um desvio de apenas 0,1%, supera os padr\u00f5es da ind\u00fastria<\/li>\n<li><strong>Entrada de tens\u00e3o universal<\/strong>: A ampla compatibilidade 12-240 VAC\/DC elimina a necessidade de v\u00e1rios modelos<\/li>\n<li><strong>Gama de temperatura superior<\/strong>: A capacidade de funcionamento de -20\u00b0C a +85\u00b0C excede muitas alternativas<\/li>\n<li><strong>Melhor anti-interfer\u00eancia<\/strong>: Concebida especificamente para um funcionamento fi\u00e1vel em ambientes industriais ruidosos<\/li>\n<li><strong>Design mais compacto<\/strong>: A pegada de 90 mm \u00d7 18 mm \u00d7 64 mm poupa espa\u00e7o valioso no painel<\/li>\n<li><strong>Indica\u00e7\u00e3o visual<\/strong>: Os indicadores LED duplos permitem uma monitoriza\u00e7\u00e3o clara do estado operacional<\/li>\n<li><strong>Vida \u00fatil mais longa<\/strong>: Vida mec\u00e2nica de 10 milh\u00f5es de opera\u00e7\u00f5es e vida el\u00e9ctrica de 100.000 ciclos<\/li>\n<\/ul>\n<h2>Conclus\u00e3o<\/h2>\n<p>O rel\u00e9 de tempo de fun\u00e7\u00e3o \u00fanica FCT18-Q representa uma solu\u00e7\u00e3o ideal para aplica\u00e7\u00f5es de temporiza\u00e7\u00e3o industrial que requerem precis\u00e3o, fiabilidade e facilidade de utiliza\u00e7\u00e3o. Com as suas defini\u00e7\u00f5es de intervalo de tempo alargado, compatibilidade com fontes de alimenta\u00e7\u00e3o universais e constru\u00e7\u00e3o robusta, proporciona um desempenho excecional em in\u00fameras aplica\u00e7\u00f5es.<\/p>\n<p>Quer esteja a conceber um novo sistema de controlo ou a atualizar o equipamento existente, o FCT18-Q oferece a combina\u00e7\u00e3o perfeita de funcionalidade, durabilidade e valor. A sua rotulagem clara, configura\u00e7\u00e3o simples e capacidades de temporiza\u00e7\u00e3o precisas fazem dele a escolha ideal para engenheiros e t\u00e9cnicos que procuram um controlo de temporiza\u00e7\u00e3o fi\u00e1vel.<\/p>\n<p>Para obter mais informa\u00e7\u00f5es sobre o FCT18-Q ou para discutir os requisitos espec\u00edficos da sua aplica\u00e7\u00e3o, contacte a nossa equipa de apoio t\u00e9cnico ou visite o nosso s\u00edtio Web em viox.com.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<div class=\"markdown\">\n<p>O rel\u00e9 de tempo de fun\u00e7\u00e3o \u00fanica VIOX FCT18-Q fornece temporiza\u00e7\u00e3o tripla de atraso de desligamento (borda ascendente) para aplica\u00e7\u00f5es de controlo industrial. Apresenta uma ampla gama de 0,1s-100 dias, erro &lt;0,5%, controlo NPN\/PNP, 1 ou 2 contactos SPDT, montagem em calha DIN e fonte de alimenta\u00e7\u00e3o universal AC\/DC 12-240V.<\/p>\n<\/div>\n<div class=\"MessageFooter-cvwndn leDsBF\">\n<div class=\"MessageMetadata-claACb fcypgW message-tokens has-metrics\"><\/div>\n<\/div>","protected":false},"featured_media":14360,"comment_status":"closed","ping_status":"closed","template":"","meta":{"inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[],"product_cat":[123,196],"product_tag":[],"class_list":{"0":"post-14354","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-relay","7":"product_cat-time-relay","8":"desktop-align-left","9":"tablet-align-left","10":"mobile-align-left","12":"first","13":"instock","14":"shipping-taxable","15":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/test.viox.com\/pt\/wp-json\/wp\/v2\/product\/14354","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/test.viox.com\/pt\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/test.viox.com\/pt\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/test.viox.com\/pt\/wp-json\/wp\/v2\/comments?post=14354"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/test.viox.com\/pt\/wp-json\/wp\/v2\/media\/14360"}],"wp:attachment":[{"href":"https:\/\/test.viox.com\/pt\/wp-json\/wp\/v2\/media?parent=14354"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/test.viox.com\/pt\/wp-json\/wp\/v2\/product_brand?post=14354"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/test.viox.com\/pt\/wp-json\/wp\/v2\/product_cat?post=14354"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/test.viox.com\/pt\/wp-json\/wp\/v2\/product_tag?post=14354"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}