{"id":14281,"date":"2025-03-20T09:35:32","date_gmt":"2025-03-20T01:35:32","guid":{"rendered":"https:\/\/viox.com\/?post_type=product&#038;p=14281"},"modified":"2025-03-20T09:35:32","modified_gmt":"2025-03-20T01:35:32","slug":"viox-fct18-bta-off-delay-timer-relay","status":"publish","type":"product","link":"https:\/\/test.viox.com\/pt\/produto\/viox-fct18-bta-off-delay-timer-relay\/","title":{"rendered":"VIOX FCT18-Bta Rel\u00e9 temporizador de atraso com sinal de controlo de soma"},"content":{"rendered":"<div class=\"product-intro\">\n<h2>Introdu\u00e7\u00e3o ao rel\u00e9 temporizador FCT18-Bta<\/h2>\n<p>O VIOX FCT18-Bta \u00e9 um rel\u00e9 temporizador avan\u00e7ado, concebido para um controlo de temporiza\u00e7\u00e3o preciso em sistemas de automa\u00e7\u00e3o industrial, fabrico e controlo de processos. Este vers\u00e1til rel\u00e9 temporizador oferece uma flexibilidade excecional com a sua carater\u00edstica de sinal de controlo de soma, permitindo sequ\u00eancias de temporiza\u00e7\u00e3o complexas atrav\u00e9s da adi\u00e7\u00e3o cumulativa de m\u00faltiplos sinais de entrada.<\/p>\n<p>Constru\u00eddo para ser fi\u00e1vel em ambientes exigentes, o FCT18-Bta fornece fun\u00e7\u00f5es de temporiza\u00e7\u00e3o precisas com uma margem de erro inferior a 0,5%, tornando-o ideal para aplica\u00e7\u00f5es em que a precis\u00e3o \u00e9 cr\u00edtica. A sua vasta gama de defini\u00e7\u00f5es de tempo, de 0,1 segundos a 100 dias, abrange praticamente todos os requisitos de temporiza\u00e7\u00e3o industrial, enquanto a compatibilidade abrangente da fonte de alimenta\u00e7\u00e3o (12-240 VAC\/DC) assegura uma integra\u00e7\u00e3o perfeita em quase todos os sistemas el\u00e9ctricos.<\/p>\n<h2>Compreender a funcionalidade do rel\u00e9 do temporizador de desfasamento<\/h2>\n<p>O FCT18-Bta funciona segundo o princ\u00edpio do temporizador fora de atraso, uma das fun\u00e7\u00f5es de temporiza\u00e7\u00e3o mais utilizadas nos sistemas de controlo industrial. Ao contr\u00e1rio dos temporizadores normais, um rel\u00e9 temporizador off-delay mant\u00e9m a sua sa\u00edda num estado ativo enquanto o sinal de entrada est\u00e1 presente e continua a manter este estado durante um per\u00edodo pr\u00e9-determinado ap\u00f3s o sinal de entrada ser removido.<\/p>\n<h3>Como funciona a fun\u00e7\u00e3o de atraso de desligamento do FCT18-Bta:<\/h3>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-14282\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-Bta-Off-delay-Timer-Relay-with-Summation-Control-Signal-timing-function.webp\" alt=\"VIOX FCT18-Bta Off-delay Timer Relay with Summation Control Signal timing function\" width=\"884\" height=\"308\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-Bta-Off-delay-Timer-Relay-with-Summation-Control-Signal-timing-function.webp 884w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-Bta-Off-delay-Timer-Relay-with-Summation-Control-Signal-timing-function-300x105.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-Bta-Off-delay-Timer-Relay-with-Summation-Control-Signal-timing-function-768x268.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-Bta-Off-delay-Timer-Relay-with-Summation-Control-Signal-timing-function-18x6.webp 18w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-Bta-Off-delay-Timer-Relay-with-Summation-Control-Signal-timing-function-600x209.webp 600w\" sizes=\"(max-width: 884px) 100vw, 884px\" \/><\/p>\n<ol>\n<li><strong>Estado inicial<\/strong>: Quando a alimenta\u00e7\u00e3o (Un) \u00e9 aplicada ao rel\u00e9, a sa\u00edda permanece inativa.<\/li>\n<li><strong>Acionamento<\/strong>: Quando o sinal de controlo (S) \u00e9 ativado, o rel\u00e9 de sa\u00edda (R) passa imediatamente para o estado ativo.<\/li>\n<li><strong>Temporiza\u00e7\u00e3o fora de atraso<\/strong>: Quando o sinal de controlo (S) \u00e9 retirado, o temporizador come\u00e7a a contar.<\/li>\n<li><strong>Recurso de totaliza\u00e7\u00e3o<\/strong>: Com a capacidade \u00fanica de controlo de soma, o FCT18-Bta soma v\u00e1rios impulsos de entrada (t1 + t2 + ... + tx) para criar um per\u00edodo de temporiza\u00e7\u00e3o total (T).<\/li>\n<li><strong>Conclus\u00e3o<\/strong>: Ap\u00f3s o tempo de atraso definido, o rel\u00e9 de sa\u00edda volta ao seu estado inativo.<\/li>\n<\/ol>\n<p>Este comportamento de temporiza\u00e7\u00e3o torna o FCT18-Bta particularmente valioso em aplica\u00e7\u00f5es que requerem sequ\u00eancias precisas de paragem de equipamento, per\u00edodos de arrefecimento ou transi\u00e7\u00f5es de processo atrasadas.<\/p>\n<h2>Principais carater\u00edsticas e vantagens do rel\u00e9 temporizador de desfasamento FCT18-Bta<\/h2>\n<h3>Flexibilidade alargada do intervalo de tempo<\/h3>\n<ul>\n<li><strong>Amplo espetro de temporiza\u00e7\u00e3o<\/strong>: Desde intervalos r\u00e1pidos de 0,1 segundos at\u00e9 per\u00edodos alargados de 100 dias<\/li>\n<li><strong>10 intervalos de tempo selecion\u00e1veis<\/strong>: 0.1-1s, 1-10s, 0.1-1m, 1-10m, 0.1-1hr, 1-10hr, 0.1-1day, 1-10day, 3-30day, 10-100day<\/li>\n<li><strong>Ajuste preciso do r\u00e1cio<\/strong>: 18 ajustes de r\u00e1cio de 10% a 100% para um ajuste fino dentro de cada intervalo de tempo<\/li>\n<\/ul>\n<h3>Especifica\u00e7\u00f5es el\u00e9ctricas superiores<\/h3>\n<ul>\n<li><strong>Fonte de alimenta\u00e7\u00e3o universal<\/strong>: Compat\u00edvel com sistemas de 12 a 240 VAC\/DC<\/li>\n<li><strong>Baixo consumo de energia<\/strong>: Apenas 3,5VA (AC) ou 2,0W (DC)<\/li>\n<li><strong>Toler\u00e2ncia de tens\u00e3o generosa<\/strong>: -15% a +10%<\/li>\n<li><strong>Classifica\u00e7\u00e3o fi\u00e1vel dos contactos<\/strong>: At\u00e9 16A por contacto para cargas exigentes<\/li>\n<\/ul>\n<h3>Durabilidade e desempenho melhorados<\/h3>\n<ul>\n<li><strong>Vida mec\u00e2nica impressionante<\/strong>: 10 milh\u00f5es de opera\u00e7\u00f5es<\/li>\n<li><strong>Vida el\u00e9ctrica substancial<\/strong>: 1 milh\u00e3o de opera\u00e7\u00f5es \u00e0 carga nominal<\/li>\n<li><strong>Excelente estabilidade de temperatura<\/strong>: 0,05%\/\u00b0C coeficiente de temperatura<\/li>\n<li><strong>Elevada precis\u00e3o de temporiza\u00e7\u00e3o<\/strong>: Desvio de tempo de apenas 0,1%<\/li>\n<li><strong>Precis\u00e3o da repeti\u00e7\u00e3o<\/strong>: Dentro de 0,5% para um desempenho consistente<\/li>\n<\/ul>\n<h3>Especifica\u00e7\u00f5es ambientais robustas<\/h3>\n<ul>\n<li><strong>Ampla gama de temperaturas de funcionamento<\/strong>: -20\u00b0C a +60\u00b0C (-4\u00b0F a +140\u00b0F)<\/li>\n<li><strong>Intervalo de temperatura de armazenamento<\/strong>: -40\u00b0C a +85\u00b0C (-40\u00b0F a +185\u00b0F)<\/li>\n<li><strong>Prote\u00e7\u00e3o de entrada IP20<\/strong>: Prote\u00e7\u00e3o contra objectos s\u00f3lidos de dimens\u00e3o superior a 12 mm<\/li>\n<li><strong>Capacidade para grandes altitudes<\/strong>: Funciona de forma fi\u00e1vel em altitudes at\u00e9 2200 m<\/li>\n<li><strong>Montagem em trilho DIN<\/strong>: Compatibilidade com a norma EN\/IEC 60715 para uma instala\u00e7\u00e3o f\u00e1cil<\/li>\n<\/ul>\n<h3>Design de f\u00e1cil utiliza\u00e7\u00e3o<\/h3>\n<ul>\n<li><strong>Indicadores LED integrados<\/strong>: Verde para a alimenta\u00e7\u00e3o el\u00e9ctrica, Vermelho para o estado do rel\u00e9<\/li>\n<li><strong>Defini\u00e7\u00f5es intuitivas do seletor<\/strong>: Controlos de tempo e r\u00e1cio facilmente ajust\u00e1veis<\/li>\n<li><strong>Dimens\u00f5es compactas<\/strong>Design eficiente em termos de espa\u00e7o: 90 mm \u00d7 18 mm \u00d7 64 mm<\/li>\n<li><strong>Constru\u00e7\u00e3o leve<\/strong>: Cerca de 90g para um manuseamento f\u00e1cil<\/li>\n<li><strong>Diagramas de cablagem claros<\/strong>: Impresso no aparelho para uma instala\u00e7\u00e3o simples<\/li>\n<\/ul>\n<h2>Especifica\u00e7\u00f5es t\u00e9cnicas<\/h2>\n<h3>Variantes do modelo<\/h3>\n<p>O FCT18-Bta est\u00e1 dispon\u00edvel em v\u00e1rias configura\u00e7\u00f5es com base no seguinte sistema de codifica\u00e7\u00e3o:<\/p>\n<p><strong>FCT18-Bta (1) (2) (3) (4)<\/strong><\/p>\n<ol>\n<li><strong>Fun\u00e7\u00e3o<\/strong>\n<ul>\n<li>Bta: Atraso com controlo da soma<\/li>\n<\/ul>\n<\/li>\n<li><strong>Tipo de sa\u00edda<\/strong>\n<ul>\n<li>1: 1CO contacto (um contacto de comuta\u00e7\u00e3o)<\/li>\n<li>2: 2CO contactos (dois contactos de comuta\u00e7\u00e3o)<\/li>\n<\/ul>\n<\/li>\n<li><strong>Tens\u00e3o de alimenta\u00e7\u00e3o<\/strong>\n<ul>\n<li>A: AC 230V<\/li>\n<li>D: DC 24V<\/li>\n<li>W: AC\/DC 12-240V (fonte de alimenta\u00e7\u00e3o universal)<\/li>\n<\/ul>\n<\/li>\n<li><strong>Sinal de controlo<\/strong>\n<ul>\n<li>N: NPN (comuta\u00e7\u00e3o negativa)<\/li>\n<li>P: PNP (comuta\u00e7\u00e3o positiva)<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n<h3>Tabela de especifica\u00e7\u00f5es pormenorizadas<\/h3>\n<table>\n<tbody>\n<tr>\n<th>Par\u00e2metro<\/th>\n<th>FCT18-Bta1<\/th>\n<th>FCT18-Bta2<\/th>\n<\/tr>\n<tr>\n<td>Terminal de entrada<\/td>\n<td>A1-A2<\/td>\n<td>A1-A2<\/td>\n<\/tr>\n<tr>\n<td>Gama de tens\u00f5es<\/td>\n<td>AC 230V \/ DC24V \/ AC\/DC 12-240V<\/td>\n<td>AC 230V \/ DC24V \/ AC\/DC 12-240V<\/td>\n<\/tr>\n<tr>\n<td>Consumo de energia<\/td>\n<td>AC 3,5VA\/ DC 2,0W<\/td>\n<td>AC 3,5VA\/ DC 2,0W<\/td>\n<\/tr>\n<tr>\n<td>Toler\u00e2ncia de tens\u00e3o<\/td>\n<td>-15% ~ +10%<\/td>\n<td>-15% ~ +10%<\/td>\n<\/tr>\n<tr>\n<td>Indica\u00e7\u00e3o de alimenta\u00e7\u00e3o<\/td>\n<td>LED verde<\/td>\n<td>LED verde<\/td>\n<\/tr>\n<tr>\n<td>Indica\u00e7\u00e3o do rel\u00e9<\/td>\n<td>LED vermelho<\/td>\n<td>LED vermelho<\/td>\n<\/tr>\n<tr>\n<td>Intervalos de tempo<\/td>\n<td>0,1s-100dias<\/td>\n<td>0,1s-100dias<\/td>\n<\/tr>\n<tr>\n<td>Defini\u00e7\u00e3o do tempo<\/td>\n<td>Bot\u00e3o<\/td>\n<td>Bot\u00e3o<\/td>\n<\/tr>\n<tr>\n<td>Desvio de tempo<\/td>\n<td>0.1%<\/td>\n<td>0.1%<\/td>\n<\/tr>\n<tr>\n<td>Precis\u00e3o da repeti\u00e7\u00e3o<\/td>\n<td>0.5%<\/td>\n<td>0.5%<\/td>\n<\/tr>\n<tr>\n<td>Coeficiente de temperatura<\/td>\n<td>0,05%\/\u00b0C, a=20\u00b0C (0,05%\/\u00b0F, a=68\u00b0F)<\/td>\n<td>0,05%\/\u00b0C, a=20\u00b0C (0,05%\/\u00b0F, a=68\u00b0F)<\/td>\n<\/tr>\n<tr>\n<td>Contacto de sa\u00edda<\/td>\n<td>1\u00d7SPDT<\/td>\n<td>2\u00d7SPDT<\/td>\n<\/tr>\n<tr>\n<td>Corrente nominal<\/td>\n<td>1\u00d716A<\/td>\n<td>2\u00d716A<\/td>\n<\/tr>\n<tr>\n<td>Vida mec\u00e2nica<\/td>\n<td>1\u00d710\u2077<\/td>\n<td>1\u00d710\u2077<\/td>\n<\/tr>\n<tr>\n<td>Vida el\u00e9ctrica<\/td>\n<td>1\u00d710\u2075<\/td>\n<td>1\u00d710\u2075<\/td>\n<\/tr>\n<tr>\n<td>Temperatura ambiente<\/td>\n<td>-20 ... +60\u00b0C \/ -40 ... +85\u00b0C<\/td>\n<td>-20 ... +60\u00b0C \/ -40 ... +85\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Montagem<\/td>\n<td>Calha DIN EN\/IEC 60715<\/td>\n<td>Calha DIN EN\/IEC 60715<\/td>\n<\/tr>\n<tr>\n<td>Classifica\u00e7\u00e3o IP<\/td>\n<td>IP20<\/td>\n<td>IP20<\/td>\n<\/tr>\n<tr>\n<td>Comprimento de decapagem<\/td>\n<td>7mm (0.28in)<\/td>\n<td>7mm (0.28in)<\/td>\n<\/tr>\n<tr>\n<td>Altitude de instala\u00e7\u00e3o<\/td>\n<td>\u22642200m<\/td>\n<td>\u22642200m<\/td>\n<\/tr>\n<tr>\n<td>N\u00edvel de polui\u00e7\u00e3o<\/td>\n<td>2<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td>Tamanho m\u00e1ximo do cabo<\/td>\n<td>AWG13-20 0,4N-m<\/td>\n<td>AWG13-20 0,4N-m<\/td>\n<\/tr>\n<tr>\n<td>Dimens\u00e3o<\/td>\n<td>90mm\u00d718mm\u00d764mm<\/td>\n<td>90mm\u00d718mm\u00d764mm<\/td>\n<\/tr>\n<tr>\n<td>Peso<\/td>\n<td>cerca de 90g<\/td>\n<td>cerca de 90g<\/td>\n<\/tr>\n<tr>\n<td>Normas<\/td>\n<td>GB\/T 14048.5, IEC60947-5-1, EN6812-1<\/td>\n<td>GB\/T 14048.5, IEC60947-5-1, EN6812-1<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Guia de instala\u00e7\u00e3o e cablagem<\/h2>\n<h3>Op\u00e7\u00f5es de cablagem<\/h3>\n<p>O FCT18-Bta oferece duas op\u00e7\u00f5es de sinal de controlo para acomodar diferentes arquitecturas de sistema:<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-14283\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-Bta-Off-delay-Timer-Relay-with-Summation-Control-Signal-wiring.webp\" alt=\"VIOX FCT18-Bta Off-delay Timer Relay with Summation Control Signal wiring\" width=\"402\" height=\"392\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-Bta-Off-delay-Timer-Relay-with-Summation-Control-Signal-wiring.webp 402w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-Bta-Off-delay-Timer-Relay-with-Summation-Control-Signal-wiring-300x293.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-Bta-Off-delay-Timer-Relay-with-Summation-Control-Signal-wiring-12x12.webp 12w\" sizes=\"(max-width: 402px) 100vw, 402px\" \/><\/p>\n<h4>Configura\u00e7\u00e3o NPN<\/h4>\n<ul>\n<li>Terminais de entrada: A1 (DC+ \/ AC L), A2 (DC- \/ AC N), S (Sinal)<\/li>\n<li>Liga\u00e7\u00e3o do sinal de controlo entre S e A2<\/li>\n<li>Terminais de sa\u00edda: 11, 12, 14 para o modelo de contacto \u00fanico<\/li>\n<li>Terminais de sa\u00edda: 11, 12, 14, 21, 22, 24 para o modelo de contacto duplo<\/li>\n<\/ul>\n<h4>Configura\u00e7\u00e3o PNP<\/h4>\n<ul>\n<li>Terminais de entrada: A1 (DC+ \/ AC L), A2 (DC- \/ AC N), S (Sinal)<\/li>\n<li>Liga\u00e7\u00e3o do sinal de controlo entre S e A1<\/li>\n<li>Terminais de sa\u00edda: 11, 12, 14 para o modelo de contacto \u00fanico<\/li>\n<li>Terminais de sa\u00edda: 11, 12, 14, 21, 22, 24 para o modelo de contacto duplo<\/li>\n<\/ul>\n<h3>Diretrizes de instala\u00e7\u00e3o<\/h3>\n<ol>\n<li>Montar o rel\u00e9 numa calha DIN standard de 35mm de acordo com a norma EN\/IEC 60715<\/li>\n<li>Assegurar uma ventila\u00e7\u00e3o adequada \u00e0 volta do dispositivo<\/li>\n<li>Manter uma dist\u00e2ncia m\u00ednima de 10 mm dos dispositivos adjacentes<\/li>\n<li>Utilize um comprimento de desencapamento de fio de 7 mm (0,28 pol.)<\/li>\n<li>Apertar os parafusos dos terminais com um bin\u00e1rio de 0,4 N-m<\/li>\n<li>Selecionar o calibre de fio adequado (AWG13-20)<\/li>\n<\/ol>\n<h2>Procedimento de defini\u00e7\u00e3o da hora<\/h2>\n<p>O FCT18-Bta possui um sistema intuitivo de regula\u00e7\u00e3o com dois bot\u00f5es para um controlo preciso do tempo:<\/p>\n<h3>Passo 1: Selecionar o intervalo de tempo<\/h3>\n<p>Utilizando o interrutor rotativo superior, selecione uma das 10 op\u00e7\u00f5es de intervalo de tempo:<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-14284\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-Bta-Off-delay-Timer-Relay-with-Summation-Control-Signal-time-range.webp\" alt=\"VIOX FCT18-Bta Off-delay Timer Relay with Summation Control Signal time range\" width=\"854\" height=\"296\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-Bta-Off-delay-Timer-Relay-with-Summation-Control-Signal-time-range.webp 854w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-Bta-Off-delay-Timer-Relay-with-Summation-Control-Signal-time-range-300x104.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-Bta-Off-delay-Timer-Relay-with-Summation-Control-Signal-time-range-768x266.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-Bta-Off-delay-Timer-Relay-with-Summation-Control-Signal-time-range-18x6.webp 18w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-Bta-Off-delay-Timer-Relay-with-Summation-Control-Signal-time-range-600x208.webp 600w\" sizes=\"(max-width: 854px) 100vw, 854px\" \/><\/p>\n<ul>\n<li>0.1-1s<\/li>\n<li>1-10s<\/li>\n<li>0.1-1m<\/li>\n<li>1-10m<\/li>\n<li>0,1-1 hora<\/li>\n<li>1-10 horas<\/li>\n<li>0,1-1dia<\/li>\n<li>1-10 dias<\/li>\n<li>3-30 dias<\/li>\n<li>10-100 dias<\/li>\n<\/ul>\n<h3>Passo 2: Definir a percentagem do r\u00e1cio<\/h3>\n<p>Utilizando o interrutor rotativo inferior, selecione a percentagem do intervalo de tempo (de 10% a 100%):<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-14285\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-Bta-Off-delay-Timer-Relay-with-Summation-Control-Signal-ratio-setting.webp\" alt=\"VIOX FCT18-Bta Off-delay Timer Relay with Summation Control Signal ratio setting\" width=\"972\" height=\"256\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-Bta-Off-delay-Timer-Relay-with-Summation-Control-Signal-ratio-setting.webp 972w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-Bta-Off-delay-Timer-Relay-with-Summation-Control-Signal-ratio-setting-300x79.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-Bta-Off-delay-Timer-Relay-with-Summation-Control-Signal-ratio-setting-768x202.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-Bta-Off-delay-Timer-Relay-with-Summation-Control-Signal-ratio-setting-18x5.webp 18w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-Bta-Off-delay-Timer-Relay-with-Summation-Control-Signal-ratio-setting-600x158.webp 600w\" sizes=\"(max-width: 972px) 100vw, 972px\" \/><\/p>\n<ul>\n<li>10%, 15%, 20%, 25%, 30%, 35%, 40%, 45%, 50%, 55%<\/li>\n<li>60%, 65%, 70%, 75%, 80%, 85%, 90%, 95%, 100%<\/li>\n<\/ul>\n<h3>Exemplo de defini\u00e7\u00f5es:<\/h3>\n<ul>\n<li>Para um atraso de 5 segundos: Selecione o intervalo 1-10s e o r\u00e1cio 50%<\/li>\n<li>Para um atraso de 2 horas: Selecionar o intervalo de 1-10 horas e o r\u00e1cio 20%<\/li>\n<li>Para um atraso de 45 dias: Selecionar o intervalo de 10-100 dias e o r\u00e1cio 45%<\/li>\n<\/ul>\n<h2>Dimens\u00e3o<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-14286\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-Bta-Off-delay-Timer-Relay-with-Summation-Control-Signal-dimension.webp\" alt=\"VIOX FCT18-Bta Off-delay Timer Relay with Summation Control Signal dimension\" width=\"438\" height=\"390\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-Bta-Off-delay-Timer-Relay-with-Summation-Control-Signal-dimension.webp 438w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-Bta-Off-delay-Timer-Relay-with-Summation-Control-Signal-dimension-300x267.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-Bta-Off-delay-Timer-Relay-with-Summation-Control-Signal-dimension-13x12.webp 13w\" sizes=\"(max-width: 438px) 100vw, 438px\" \/><\/p>\n<h2>Aplica\u00e7\u00f5es do rel\u00e9 temporizador FCT18-Bta<\/h2>\n<h3>Automa\u00e7\u00e3o industrial<\/h3>\n<ul>\n<li><strong>Controlo de tapetes transportadores<\/strong>: Assegurar que os sistemas de transporte continuam a funcionar durante um per\u00edodo de tempo definido ap\u00f3s a cessa\u00e7\u00e3o dos sinais dos sensores<\/li>\n<li><strong>Sequ\u00eancias de paragem da m\u00e1quina<\/strong>: Permite que os sistemas auxiliares continuem a funcionar depois de a alimenta\u00e7\u00e3o principal ser desligada<\/li>\n<li><strong>Sistemas de arrefecimento<\/strong>: Manter o funcionamento do ventilador durante um per\u00edodo pr\u00e9-determinado ap\u00f3s a paragem do equipamento<\/li>\n<li><strong>Opera\u00e7\u00f5es sequenciais<\/strong>: Coordena\u00e7\u00e3o de v\u00e1rias etapas do processo com intervalos de tempo precisos<\/li>\n<\/ul>\n<h3>Gest\u00e3o de edif\u00edcios<\/h3>\n<ul>\n<li><strong>Controlo da ventila\u00e7\u00e3o<\/strong>: Funcionamento prolongado do ventilador nas casas de banho ou cozinhas depois de os interruptores de luz estarem desligados<\/li>\n<li><strong>Ilumina\u00e7\u00e3o das escadas<\/strong>: Manter a ilumina\u00e7\u00e3o durante um per\u00edodo de sa\u00edda confort\u00e1vel ap\u00f3s premir o bot\u00e3o<\/li>\n<li><strong>Sistemas de seguran\u00e7a<\/strong>: Ativa\u00e7\u00e3o ou desativa\u00e7\u00e3o retardada de componentes de seguran\u00e7a em sistemas de controlo de acesso<\/li>\n<li><strong>Coordena\u00e7\u00e3o HVAC<\/strong>: Sequenciar o funcionamento do equipamento de aquecimento\/arrefecimento com atrasos de tempo adequados<\/li>\n<\/ul>\n<h3>Gest\u00e3o da energia<\/h3>\n<ul>\n<li><strong>Desvio de carga<\/strong>: Desligamento sequencial de cargas n\u00e3o cr\u00edticas durante restri\u00e7\u00f5es de energia<\/li>\n<li><strong>Sistemas de geradores<\/strong>: Coordena\u00e7\u00e3o dos per\u00edodos de arrefecimento dos geradores de emerg\u00eancia<\/li>\n<li><strong>Coordena\u00e7\u00e3o UPS<\/strong>: Gest\u00e3o de paragens ordenadas durante as transi\u00e7\u00f5es de energia<\/li>\n<li><strong>Energia solar\/alternativa<\/strong>: Controlo do tempo do equipamento durante a disponibilidade de energia vari\u00e1vel<\/li>\n<\/ul>\n<h3>Controlo de processos<\/h3>\n<ul>\n<li><strong>Dosagem de produtos qu\u00edmicos<\/strong>: Assegurar uma temporiza\u00e7\u00e3o exacta nos processos de adi\u00e7\u00e3o qu\u00edmica<\/li>\n<li><strong>Opera\u00e7\u00f5es de mistura<\/strong>: Controlo do tempo de agita\u00e7\u00e3o ap\u00f3s a adi\u00e7\u00e3o de material<\/li>\n<li><strong>Processamento de lotes<\/strong>: Gest\u00e3o de opera\u00e7\u00f5es sequenciais em processos de fabrico<\/li>\n<li><strong>Tratamento da \u00e1gua<\/strong>: Coordena\u00e7\u00e3o do funcionamento das bombas e dos ciclos de tratamento<\/li>\n<\/ul>\n<h3>Carater\u00edstica especial: Sinal de controlo de totaliza\u00e7\u00e3o<\/h3>\n<p>A capacidade de controlo de soma distinta do FCT18-Bta representa um avan\u00e7o significativo na tecnologia de rel\u00e9s temporizadores. Esta carater\u00edstica permite que o rel\u00e9 acumule m\u00faltiplos sinais de entrada (t1 + t2 + ... + tx), criando um per\u00edodo de atraso combinado (T) que representa a soma de todos os sinais individuais.<\/p>\n<p>Esta funcionalidade \u00e9 particularmente valiosa em aplica\u00e7\u00f5es em que:<\/p>\n<ul>\n<li>As vari\u00e1veis do processo determinam as necessidades de temporiza\u00e7\u00e3o \u00f3ptimas<\/li>\n<li>As entradas m\u00faltiplas do operador influenciam os requisitos de temporiza\u00e7\u00e3o<\/li>\n<li>Os eventos do sistema devem acumular-se para desencadear ac\u00e7\u00f5es subsequentes<\/li>\n<li>S\u00e3o necess\u00e1rias adapta\u00e7\u00f5es flex\u00edveis de tempo com base nas condi\u00e7\u00f5es de tempo de execu\u00e7\u00e3o<\/li>\n<\/ul>\n<h2>Porqu\u00ea escolher o rel\u00e9 temporizador VIOX FCT18-Bta?<\/h2>\n<h3>Fiabilidade superior<\/h3>\n<p>Com um erro de temporiza\u00e7\u00e3o inferior a 0,5%, estabilidade de temperatura de 0,05%\/\u00b0C e um ciclo de vida mec\u00e2nico de 10 milh\u00f5es de opera\u00e7\u00f5es, o FCT18-Bta proporciona um desempenho consistente em ambientes industriais exigentes.<\/p>\n<h3>Versatilidade excecional<\/h3>\n<p>A combina\u00e7\u00e3o de amplas gamas de tempo (0,1s a 100 dias), op\u00e7\u00f5es flex\u00edveis de alimenta\u00e7\u00e3o (12-240 VAC\/DC) e configura\u00e7\u00f5es de sinal de controlo duplo (NPN\/PNP) torna o FCT18-Bta adapt\u00e1vel a praticamente qualquer aplica\u00e7\u00e3o de controlo de temporiza\u00e7\u00e3o.<\/p>\n<h3>Facilidade de implementa\u00e7\u00e3o<\/h3>\n<p>Os diagramas de cablagem claros impressos no dispositivo, os controlos de marca\u00e7\u00e3o intuitivos e a montagem em calha DIN padr\u00e3o garantem uma instala\u00e7\u00e3o e configura\u00e7\u00e3o simples sem ferramentas ou forma\u00e7\u00e3o especializadas.<\/p>\n<h3>Funcionalidades avan\u00e7adas<\/h3>\n<p>A capacidade do sinal de controlo de soma fornece op\u00e7\u00f5es sofisticadas de controlo de temporiza\u00e7\u00e3o n\u00e3o dispon\u00edveis em rel\u00e9s temporizadores padr\u00e3o, permitindo sequ\u00eancias de temporiza\u00e7\u00e3o complexas com requisitos m\u00ednimos de componentes.<\/p>\n<h3>Conformidade e qualidade<\/h3>\n<p>Fabricado de acordo com rigorosas normas internacionais, incluindo GB\/T 14048.5, IEC60947-5-1 e EN6812-1, o FCT18-Bta garante um funcionamento fi\u00e1vel e compatibilidade com sistemas el\u00e9ctricos globais.<\/p>\n<h2>Conclus\u00e3o<\/h2>\n<p>O rel\u00e9 temporizador sem atraso VIOX FCT18-Bta com sinal de controlo de soma representa um equil\u00edbrio perfeito entre precis\u00e3o, versatilidade e fiabilidade para aplica\u00e7\u00f5es de temporiza\u00e7\u00e3o industrial. A sua vasta gama de op\u00e7\u00f5es de temporiza\u00e7\u00e3o, a compatibilidade com fontes de alimenta\u00e7\u00e3o universais e a capacidade \u00fanica de controlo por soma fazem dele a solu\u00e7\u00e3o ideal para requisitos de controlo de temporiza\u00e7\u00e3o simples e complexos.<\/p>\n<p>Quer seja utilizado na automa\u00e7\u00e3o do fabrico, em sistemas de gest\u00e3o de edif\u00edcios, em aplica\u00e7\u00f5es de controlo de energia ou na coordena\u00e7\u00e3o de processos, o FCT18-Bta proporciona um desempenho de temporiza\u00e7\u00e3o consistente e preciso numa embalagem compacta e de f\u00e1cil utiliza\u00e7\u00e3o. Com a sua fiabilidade comprovada e carater\u00edsticas avan\u00e7adas, este rel\u00e9 temporizador fornece aos engenheiros e integradores de sistemas uma ferramenta poderosa para implementar estrat\u00e9gias sofisticadas de controlo de temporiza\u00e7\u00e3o, mantendo a simplicidade de instala\u00e7\u00e3o e funcionamento.<\/p>\n<p>Para obter mais informa\u00e7\u00f5es sobre o rel\u00e9 temporizador FCT18-Bta ou para discutir as suas necessidades espec\u00edficas de aplica\u00e7\u00e3o de controlo de temporiza\u00e7\u00e3o, contacte o apoio t\u00e9cnico da VIOX ou visite o nosso website em viox.com.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<div class=\"markdown\">\n<p>O rel\u00e9 temporizador VIOX FCT18-Bta oferece temporiza\u00e7\u00e3o precisa de atraso de desligamento (0,1s-100 dias), somando pulsos de sinal de controle NPN\/PNP. Apresenta erro &lt;0,5%, 1 ou 2 contactos SPDT, montagem em calha DIN e suporte AC\/DC 12-240V. Ideal para automa\u00e7\u00e3o industrial que necessita de temporiza\u00e7\u00e3o cumulativa de atraso de desligamento.<\/p>\n<\/div>\n<div class=\"MessageFooter-cvwndn leDsBF\">\n<div class=\"MessageMetadata-claACb fcypgW message-tokens has-metrics\"><\/div>\n<\/div>","protected":false},"featured_media":14287,"comment_status":"closed","ping_status":"closed","template":"","meta":{"inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[],"product_cat":[196,123],"product_tag":[],"class_list":{"0":"post-14281","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-time-relay","7":"product_cat-relay","8":"desktop-align-left","9":"tablet-align-left","10":"mobile-align-left","12":"first","13":"instock","14":"shipping-taxable","15":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/test.viox.com\/pt\/wp-json\/wp\/v2\/product\/14281","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/test.viox.com\/pt\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/test.viox.com\/pt\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/test.viox.com\/pt\/wp-json\/wp\/v2\/comments?post=14281"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/test.viox.com\/pt\/wp-json\/wp\/v2\/media\/14287"}],"wp:attachment":[{"href":"https:\/\/test.viox.com\/pt\/wp-json\/wp\/v2\/media?parent=14281"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/test.viox.com\/pt\/wp-json\/wp\/v2\/product_brand?post=14281"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/test.viox.com\/pt\/wp-json\/wp\/v2\/product_cat?post=14281"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/test.viox.com\/pt\/wp-json\/wp\/v2\/product_tag?post=14281"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}