{"id":20076,"date":"2025-11-29T01:45:00","date_gmt":"2025-11-28T17:45:00","guid":{"rendered":"https:\/\/viox.com\/?p=20076"},"modified":"2025-11-15T15:45:18","modified_gmt":"2025-11-15T07:45:18","slug":"solar-pv-fuse-requirements-nec-690-9-parallel-strings","status":"publish","type":"post","link":"https:\/\/test.viox.com\/pt\/solar-pv-fuse-requirements-nec-690-9-parallel-strings\/","title":{"rendered":"O \u201cParadoxo do Fus\u00edvel\u201d: Por que a NEC 690.9 diz que voc\u00ea n\u00e3o precisa de um fus\u00edvel (mas voc\u00ea pode querer um mesmo assim)"},"content":{"rendered":"<div class=\"product-intro\">\n<p>Se voc\u00ea est\u00e1 projetando um painel solar, voc\u00ea conhece a regra de ouro da engenharia el\u00e9trica: <strong>Os fios devem ser protegidos por fus\u00edveis ou <a href=\"https:\/\/test.viox.com\/pt\/mcb\/\">disjuntores<\/a>.<\/strong><\/p>\n<p>Ent\u00e3o, quando voc\u00ea se aprofunda na Se\u00e7\u00e3o 690.9 do C\u00f3digo El\u00e9trico Nacional (NEC), voc\u00ea pode se deparar com uma cl\u00e1usula que o impede de prosseguir. Ela sugere que se voc\u00ea tiver duas strings de pain\u00e9is solares conectadas em paralelo, voc\u00ea <strong>n\u00e3o<\/strong> precisa instalar fus\u00edveis.<\/p>\n<p>Isso parece errado. Parece um erro de digita\u00e7\u00e3o. Como uma fonte de energia pode n\u00e3o exigir prote\u00e7\u00e3o?<\/p>\n<p>Bem-vindo ao <strong>\u201cParadoxo do Fus\u00edvel.\u201d<\/strong><\/p>\n<p>Esta regra existe n\u00e3o porque o NEC \u00e9 negligente com a seguran\u00e7a, mas porque a f\u00edsica de um painel solar \u00e9 fundamentalmente diferente de uma bateria ou da rede el\u00e9trica. Entender este paradoxo \u00e9 a chave para distinguir um instalador de \u201cc\u00f3digo m\u00ednimo\u201d de um verdadeiro engenheiro solar.<\/p>\n<hr \/>\n<h2>A F\u00edsica: \u201cQuem Est\u00e1 Atacando Quem?\u201d<\/h2>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-20079\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-Physics-22Who-Is-Attacking-Whom221.webp\" alt=\"The Physics: &quot;Who Is Attacking Whom?&quot;\" width=\"800\" height=\"800\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-Physics-22Who-Is-Attacking-Whom221.webp 800w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-Physics-22Who-Is-Attacking-Whom221-300x300.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-Physics-22Who-Is-Attacking-Whom221-150x150.webp 150w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-Physics-22Who-Is-Attacking-Whom221-768x768.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-Physics-22Who-Is-Attacking-Whom221-12x12.webp 12w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-Physics-22Who-Is-Attacking-Whom221-600x600.webp 600w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-Physics-22Who-Is-Attacking-Whom221-100x100.webp 100w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<p>Para entender por que voc\u00ea n\u00e3o precisa de um fus\u00edvel, voc\u00ea primeiro precisa entender contra o que um fus\u00edvel est\u00e1 realmente protegendo em um sistema fotovoltaico.<\/p>\n<p>Em um circuito dom\u00e9stico padr\u00e3o, o fus\u00edvel protege o fio da <em>fonte<\/em> (a rede el\u00e9trica). Se voc\u00ea causar um curto-circuito em um fio, a rede el\u00e9trica despeja corrente infinita at\u00e9 que o fio derreta.<\/p>\n<p><strong>Pain\u00e9is solares s\u00e3o diferentes.<\/strong> Eles s\u00e3o \u201cFontes de Corrente Limitada.\u201d<\/p>\n<p>Se voc\u00ea tiver um painel solar de 10A e causar um curto-circuito em seus cabos positivo e negativo, ele n\u00e3o explodir\u00e1. Ele apenas produzir\u00e1... cerca de 10-11 Amperes (sua Corrente de Curto-Circuito, ou Isc). Ele fisicamente n\u00e3o pode produzir mais corrente do que o sol permite.<\/p>\n<p>Portanto, um painel solar <strong>n\u00e3o pode se queimar<\/strong>.<\/p>\n<p>Ent\u00e3o, por que n\u00f3s fundimos os pain\u00e9is fotovoltaicos? <strong>N\u00e3o estamos protegendo o painel de si mesmo. Estamos protegendo-o de seus vizinhos.<\/strong><\/p>\n<p>O perigo \u00e9 <strong>Corrente de Retorno<\/strong>. Se uma string falhar (por exemplo, um curto dentro de um m\u00f3dulo), as <em>outros<\/em> strings paralelas despejar\u00e3o sua energia <em>para tr\u00e1s<\/em> na string danificada.<\/p>\n<hr \/>\n<h2>A Matem\u00e1tica: A Isen\u00e7\u00e3o de \u201c2 Strings\u201d<\/h2>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-20080\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-Math-The-222-String22-Exemption.webp\" alt=\"The Math- The &quot;2-String&quot; Exemption.webp\" width=\"800\" height=\"800\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-Math-The-222-String22-Exemption.webp 800w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-Math-The-222-String22-Exemption-300x300.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-Math-The-222-String22-Exemption-150x150.webp 150w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-Math-The-222-String22-Exemption-768x768.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-Math-The-222-String22-Exemption-12x12.webp 12w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-Math-The-222-String22-Exemption-600x600.webp 600w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-Math-The-222-String22-Exemption-100x100.webp 100w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<p>Vamos executar a matem\u00e1tica que permite que o \u201cParadoxo do Fus\u00edvel\u201d exista.<\/p>\n<p><strong>As Vari\u00e1veis:<\/strong><\/p>\n<ul>\n<li><strong>Isc do Painel (Corrente de Curto-Circuito):<\/strong> 10 Amperes (O poder de ataque).<\/li>\n<li><strong>Classifica\u00e7\u00e3o M\u00e1xima do Fus\u00edvel em S\u00e9rie:<\/strong> 15 Amperes (O poder de defesa). <em>Isto est\u00e1 impresso na parte de tr\u00e1s de cada painel solar. Ele informa quanta corrente reversa o painel pode suportar antes de pegar fogo.<\/em><\/li>\n<\/ul>\n<h3>Cen\u00e1rio A: 2 Strings em Paralelo (O \u201cImpasse\u201d)<\/h3>\n<p>Voc\u00ea tem a String 1 e a String 2 conectadas em paralelo.<\/p>\n<ul>\n<li><strong>A Falha:<\/strong> A String 1 desenvolve um curto-circuito.<\/li>\n<li><strong>O Ataque:<\/strong> A String 2 flui para tr\u00e1s na String 1.<\/li>\n<li><strong>C\u00e1lculo da Corrente:<\/strong> A \u00fanica fonte de corrente \u00e9 a String 2. Ent\u00e3o, a for\u00e7a de ataque \u00e9 <strong>10 Amperes<\/strong>.<\/li>\n<li><strong>O Resultado:<\/strong> O ataque de 10A \u00e9 <strong>menor que<\/strong> o limite de 15A (Classifica\u00e7\u00e3o M\u00e1xima do Fus\u00edvel em S\u00e9rie) da String 1.<\/li>\n<\/ul>\n<p>O painel pode suportar o calor. O fio pode suportar o calor. Nenhum inc\u00eandio ocorre.<\/p>\n<p><strong>Veredicto:<\/strong> NEC 690.9 diz <strong>Nenhum Fus\u00edvel Necess\u00e1rio.<\/strong><\/p>\n<h3>Cen\u00e1rio B: 3 Strings em Paralelo (A \u201cEmboscada\u201d)<\/h3>\n<p>Agora, voc\u00ea adiciona uma terceira string.<\/p>\n<ul>\n<li><strong>A Falha:<\/strong> A String 1 desenvolve um curto-circuito.<\/li>\n<li><strong>O Ataque:<\/strong> String 2 (10A) <strong>E<\/strong> String 3 (10A) ambas fluem para tr\u00e1s na String 1.<\/li>\n<li><strong>C\u00e1lculo da Corrente:<\/strong> 10A + 10A = <strong>20 amperes<\/strong>.<\/li>\n<li><strong>O Resultado:<\/strong> O ataque de 20A \u00e9 <strong>maior que<\/strong> o limite de 15A da String 1.<\/li>\n<\/ul>\n<p>A String 1 agora est\u00e1 sobrecarregada. Ela superaquece. Ela derrete. O telhado pega fogo.<\/p>\n<p><strong>Veredicto:<\/strong> NEC 690.9 diz <strong>Fus\u00edveis s\u00e3o OBRIGAT\u00d3RIOS<\/strong> em cada string.<\/p>\n<hr \/>\n<h2>Al\u00e9m do C\u00f3digo: Por Que Voc\u00ea Deveria Fundir de Qualquer Maneira<\/h2>\n<p>Ent\u00e3o, se voc\u00ea tem um sistema de 2 strings, o c\u00f3digo diz que voc\u00ea pode economizar dinheiro e pular a fus\u00e3o da caixa combinadora.<\/p>\n<p>Mas pergunte a qualquer t\u00e9cnico de servi\u00e7o veterano, e eles dir\u00e3o: <strong>\u201cInstale os fus\u00edveis mesmo assim.\u201d<\/strong><\/p>\n<p>Aqui est\u00e1 o porqu\u00ea de o \u201cM\u00ednimo do C\u00f3digo\u201d n\u00e3o ser a \u201cMelhor Pr\u00e1tica\u201d.\u201d<\/p>\n<h3>1. O Pesadelo da \u201cDesconex\u00e3o Quente\u201d<\/h3>\n<p>A conformidade com o c\u00f3digo \u00e9 \u00f3tima at\u00e9 que voc\u00ea tenha que consertar algo.<\/p>\n<p>Se voc\u00ea pular o porta-fus\u00edvel (que geralmente atua como uma chave de desconex\u00e3o), suas strings s\u00e3o conectadas diretamente (geralmente com conectores Y).<\/p>\n<p>Se voc\u00ea precisar solucionar problemas da String 1, voc\u00ea tem que desconectar os conectores MC4. Se o sol estiver brilhando, esse circuito est\u00e1 sob carga. Puxar um conector MC4 sob carga cria um <strong>Arco DC<\/strong>\u2014uma chama de plasma que pode derreter os contatos do conector e queimar suas m\u00e3os.<\/p>\n<p>Um <strong>VIOX PV <a href=\"https:\/\/test.viox.com\/pt\/produto\/viox-dc-fuse-holder-vor-32-series\/\">Porta-fus\u00edvel<\/a><\/strong> oferece uma maneira segura e \u00e0 prova de toque de \u201cdesligar\u201d uma string antes de trabalhar nela. Voc\u00ea abre o suporte, o circuito se interrompe dentro de uma c\u00e2mara contida e voc\u00ea est\u00e1 seguro.<\/p>\n<h3>2. O Fator de \u201cPrepara\u00e7\u00e3o para o Futuro\u201d<\/h3>\n<p>Os sistemas solares crescem. Voc\u00ea pode come\u00e7ar com 2 strings hoje. Tr\u00eas anos depois, voc\u00ea pode querer adicionar uma 3\u00aa string para carregar um EV.<\/p>\n<p>Se voc\u00ea conectou seu sistema de 2 strings sem fus\u00edveis (porque \u201co C\u00f3digo disse que eu n\u00e3o precisava deles\u201d), adicionar essa 3\u00aa string de repente torna todo o seu array existente ilegal e perigoso. Voc\u00ea tem que arrancar a fia\u00e7\u00e3o e come\u00e7ar de novo.<\/p>\n<p>Se voc\u00ea instalou um <strong>Caixa combinadora VIOX<\/strong> com porta-fus\u00edveis desde o primeiro dia, adicionar uma string \u00e9 plug-and-play. Voc\u00ea j\u00e1 est\u00e1 protegido.<\/p>\n<hr \/>\n<div id='gallery-1' class='gallery galleryid-20076 gallery-columns-3 gallery-size-full'><figure class='gallery-item'>\n\t\t\t<div class='gallery-icon landscape'>\n\t\t\t\t<a href='https:\/\/test.viox.com\/pt\/?attachment_id=6294'><img decoding=\"async\" width=\"800\" height=\"800\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/RT18-32-Din-Rail-Mounted-10x38-Cartridge-690V-32A-2Pole-4Pole-Fuse-Holder.webp\" class=\"attachment-full size-full\" alt=\"RT18-32 Din Rail Mounted 10x38 Cartridge 690V 32A 2Pole 4Pole Fuse Holder\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/RT18-32-Din-Rail-Mounted-10x38-Cartridge-690V-32A-2Pole-4Pole-Fuse-Holder.webp 800w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/RT18-32-Din-Rail-Mounted-10x38-Cartridge-690V-32A-2Pole-4Pole-Fuse-Holder-300x300.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/RT18-32-Din-Rail-Mounted-10x38-Cartridge-690V-32A-2Pole-4Pole-Fuse-Holder-150x150.webp 150w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/RT18-32-Din-Rail-Mounted-10x38-Cartridge-690V-32A-2Pole-4Pole-Fuse-Holder-768x768.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/RT18-32-Din-Rail-Mounted-10x38-Cartridge-690V-32A-2Pole-4Pole-Fuse-Holder-600x600.webp 600w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/RT18-32-Din-Rail-Mounted-10x38-Cartridge-690V-32A-2Pole-4Pole-Fuse-Holder-100x100.webp 100w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/a>\n\t\t\t<\/div><\/figure><figure class='gallery-item'>\n\t\t\t<div class='gallery-icon landscape'>\n\t\t\t\t<a href='https:\/\/test.viox.com\/pt\/?attachment_id=6292'><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"800\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/RT18-63-Din-Rail-Mounted-14x51-Cartridge-690V-32A-2Pole-4Pole-Fuse-Holder.webp\" class=\"attachment-full size-full\" alt=\"VIOX RT18-63 Din Rail Mounted Fuse Holder\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/RT18-63-Din-Rail-Mounted-14x51-Cartridge-690V-32A-2Pole-4Pole-Fuse-Holder.webp 800w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/RT18-63-Din-Rail-Mounted-14x51-Cartridge-690V-32A-2Pole-4Pole-Fuse-Holder-300x300.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/RT18-63-Din-Rail-Mounted-14x51-Cartridge-690V-32A-2Pole-4Pole-Fuse-Holder-150x150.webp 150w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/RT18-63-Din-Rail-Mounted-14x51-Cartridge-690V-32A-2Pole-4Pole-Fuse-Holder-768x768.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/RT18-63-Din-Rail-Mounted-14x51-Cartridge-690V-32A-2Pole-4Pole-Fuse-Holder-600x600.webp 600w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/RT18-63-Din-Rail-Mounted-14x51-Cartridge-690V-32A-2Pole-4Pole-Fuse-Holder-100x100.webp 100w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/a>\n\t\t\t<\/div><\/figure><figure class='gallery-item'>\n\t\t\t<div class='gallery-icon landscape'>\n\t\t\t\t<a href='https:\/\/test.viox.com\/pt\/?attachment_id=6288'><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"800\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/RT18-125-Din-Rail-Mounted-22x58-Cartridge-690V-125A-2Pole-4Pole-Fuse-Holder.webp\" class=\"attachment-full size-full\" alt=\"RT18-125 Din Rail Mounted 22x58 Cartridge 690V 125A 2Pole 4Pole Fuse Holder\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/RT18-125-Din-Rail-Mounted-22x58-Cartridge-690V-125A-2Pole-4Pole-Fuse-Holder.webp 800w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/RT18-125-Din-Rail-Mounted-22x58-Cartridge-690V-125A-2Pole-4Pole-Fuse-Holder-300x300.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/RT18-125-Din-Rail-Mounted-22x58-Cartridge-690V-125A-2Pole-4Pole-Fuse-Holder-150x150.webp 150w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/RT18-125-Din-Rail-Mounted-22x58-Cartridge-690V-125A-2Pole-4Pole-Fuse-Holder-768x768.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/RT18-125-Din-Rail-Mounted-22x58-Cartridge-690V-125A-2Pole-4Pole-Fuse-Holder-600x600.webp 600w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/RT18-125-Din-Rail-Mounted-22x58-Cartridge-690V-125A-2Pole-4Pole-Fuse-Holder-100x100.webp 100w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/a>\n\t\t\t<\/div><\/figure>\n\t\t<\/div>\n\n<h2>Resumo: N\u00e3o Seja Mais Esperto Que Sua Seguran\u00e7a<\/h2>\n<p>O \u201cParadoxo do Fus\u00edvel\u201d \u00e9 uma curiosidade de engenharia divertida, mas \u00e9 uma filosofia de design ruim.<\/p>\n<p>Embora a f\u00edsica de um sistema de 2 strings possa salv\u00e1-lo de um inc\u00eandio, omitir os fus\u00edveis rouba voc\u00ea do controle, da seguran\u00e7a e da capacidade de expans\u00e3o.<\/p>\n<ul>\n<li><strong>N \u2264 2 Strings:<\/strong> Fus\u00edveis s\u00e3o opcionais (mas recomendados para isolamento).<\/li>\n<li><strong>N \u2265 3 Strings:<\/strong> Fus\u00edveis s\u00e3o obrigat\u00f3rios (para prote\u00e7\u00e3o contra inc\u00eandio).<\/li>\n<\/ul>\n<p>N\u00e3o construa apenas para a inspe\u00e7\u00e3o; construa para os 20 anos de opera\u00e7\u00e3o que se seguem.<\/p>\n<hr \/>\n<h2>O Rigor T\u00e9cnico Nota<\/h2>\n<ul>\n<li><strong>Normas:<\/strong>\n<ul>\n<li><strong>NEC 690.9 (Prote\u00e7\u00e3o Contra Sobrecorrente):<\/strong> Define os requisitos para proteger os circuitos de fonte FV.<\/li>\n<li><strong>Exce\u00e7\u00e3o:<\/strong> Fus\u00edveis n\u00e3o s\u00e3o necess\u00e1rios se as correntes de curto-circuito de todas as <em>outros<\/em> fontes n\u00e3o excederem a ampacidade dos condutores ou a classifica\u00e7\u00e3o m\u00e1xima do fus\u00edvel em s\u00e9rie do m\u00f3dulo.<\/li>\n<\/ul>\n<\/li>\n<li><strong>F\u00f3rmula:<\/strong> A regra geral para exigir fus\u00edveis \u00e9: <code>(N - 1) x Isc &gt; Classifica\u00e7\u00e3o M\u00e1xima do Fus\u00edvel em S\u00e9rie<\/code>.\n<ul>\n<li>Onde <em>N<\/em> \u00e9 o n\u00famero de strings paralelas.<\/li>\n<li><em>Isc<\/em> \u00e9 a Corrente de Curto-Circuito do painel (ajustada para fatores de seguran\u00e7a de temperatura\/irradi\u00e2ncia, geralmente 1,25).<\/li>\n<\/ul>\n<\/li>\n<li><strong>Solu\u00e7\u00f5es VIOX:<\/strong> A VIOX fabrica fus\u00edveis gPV de 10x38mm especificamente projetados para interromper as falhas de baixa sobrecorrente comuns em arrays solares DC, que os fus\u00edveis AC padr\u00e3o podem n\u00e3o conseguir eliminar.<\/li>\n<\/ul>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>If you are designing a solar array, you know the golden rule of electrical engineering: Wires must be protected by fuses or breakers. So, when you dig into the National Electrical Code (NEC) Section 690.9, you might run into a clause that stops you in your tracks. It suggests that if you have two strings [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":20083,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1],"tags":[],"class_list":["post-20076","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"_links":{"self":[{"href":"https:\/\/test.viox.com\/pt\/wp-json\/wp\/v2\/posts\/20076","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/test.viox.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/test.viox.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/test.viox.com\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/test.viox.com\/pt\/wp-json\/wp\/v2\/comments?post=20076"}],"version-history":[{"count":3,"href":"https:\/\/test.viox.com\/pt\/wp-json\/wp\/v2\/posts\/20076\/revisions"}],"predecessor-version":[{"id":20082,"href":"https:\/\/test.viox.com\/pt\/wp-json\/wp\/v2\/posts\/20076\/revisions\/20082"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/test.viox.com\/pt\/wp-json\/wp\/v2\/media\/20083"}],"wp:attachment":[{"href":"https:\/\/test.viox.com\/pt\/wp-json\/wp\/v2\/media?parent=20076"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/test.viox.com\/pt\/wp-json\/wp\/v2\/categories?post=20076"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/test.viox.com\/pt\/wp-json\/wp\/v2\/tags?post=20076"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}