{"id":19015,"date":"2025-07-28T14:33:59","date_gmt":"2025-07-28T06:33:59","guid":{"rendered":"https:\/\/viox.com\/?p=19015"},"modified":"2026-01-19T09:07:47","modified_gmt":"2026-01-19T01:07:47","slug":"dc-isolator-vs-ac-isolator-switch","status":"publish","type":"post","link":"https:\/\/test.viox.com\/pt\/dc-isolator-vs-ac-isolator-switch\/","title":{"rendered":"Interruptor Isolador CC vs Interruptor Isolador CA: Guia de Compara\u00e7\u00e3o Completo para Instala\u00e7\u00f5es El\u00e9tricas Seguras"},"content":{"rendered":"<div class=\"product-intro\">\n<div style=\"background-color: #f9f9f9; border-left: 5px solid #fd041a; padding: 20px; margin-bottom: 30px;\">\n<h2 style=\"margin-top: 0;\">Principais conclus\u00f5es<\/h2>\n<ul style=\"margin-bottom: 0;\">\n<li><strong>Fator de Cruzamento por Zero:<\/strong> A corrente AC extingue naturalmente os arcos nas passagens por zero (100-120 vezes\/seg), enquanto a corrente DC sustenta os arcos continuamente.<\/li>\n<li><strong>Diferen\u00e7as de Design:<\/strong> Os isoladores DC requerem bobinas de sopro magn\u00e9tico e c\u00e2maras de extin\u00e7\u00e3o de arco profundas, tornando-os fisicamente maiores e mais caros do que as vers\u00f5es AC.<\/li>\n<li><strong>Redu\u00e7\u00e3o de Tens\u00e3o:<\/strong> Usar um isolador AC para aplica\u00e7\u00f5es DC resulta em uma queda significativa na capacidade de tens\u00e3o (por exemplo, 690V AC \u2192 ~220V DC).<\/li>\n<li><strong>Regra de Seguran\u00e7a:<\/strong> Nunca use um isolador com classifica\u00e7\u00e3o AC para sistemas DC, como Solar FV ou Armazenamento de Bateria, para evitar riscos de inc\u00eandio e soldagem de contato.<\/li>\n<\/ul>\n<\/div>\n<p>O t\u00e9cnico de manuten\u00e7\u00e3o abre o interruptor seccionador. 600 volts, 32 amperes. Procedimento de bloqueio de rotina para um conjunto solar no telhado.<\/p>\n<p>Exceto que o interruptor n\u00e3o era classificado para CC.<\/p>\n<p>Dentro da caixa, um arco se forma entre os contatos que se separam \u2014 uma ponte de plasma brilhante e sustentada conduzindo 600V CC atrav\u00e9s do ar ionizado. Em um sistema CA, este arco se extinguiria naturalmente em 10 milissegundos, apagado na pr\u00f3xima passagem por zero da corrente. Mas a corrente CC n\u00e3o tem passagens por zero. O arco se mant\u00e9m. Os contatos come\u00e7am a se erodir. A temperatura sobe. Em segundos, o seccionador que deveria fornecer desconex\u00e3o segura se torna um condutor cont\u00ednuo de alta tens\u00e3o, exatamente quando voc\u00ea mais precisa que ele esteja isolado.<\/p>\n<p>Isso \u00e9 <strong>\u201cA Rede de Seguran\u00e7a da Passagem por Zero\u201d<\/strong>\u2014 CA tem, CC n\u00e3o. E isso muda tudo sobre como os interruptores seccionadores devem ser projetados, classificados e selecionados.<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-19021\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/isolator-switches.webp\" alt=\"isolator switches\" width=\"800\" height=\"600\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/isolator-switches.webp 800w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/isolator-switches-300x225.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/isolator-switches-768x576.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/isolator-switches-16x12.webp 16w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/isolator-switches-600x450.webp 600w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<h2>O que s\u00e3o interruptores isoladores?<\/h2>\n<p>Um <strong><a href=\"https:\/\/test.viox.com\/pt\/what-is-a-dc-isolator-switch\/\">interruptor isolador<\/a><\/strong> (tamb\u00e9m chamado de seccionador ou interruptor seccionador) \u00e9 um dispositivo de comuta\u00e7\u00e3o mec\u00e2nico projetado para isolar um circuito el\u00e9trico de sua fonte de alimenta\u00e7\u00e3o, garantindo manuten\u00e7\u00e3o e reparo seguros. Regido por <a href=\"https:\/\/test.viox.com\/pt\/iec-60947-3-utilization-categories-guide\/\">IEC 60947-3:2020<\/a> para quadros de distribui\u00e7\u00e3o de baixa tens\u00e3o (at\u00e9 1000V AC e 1500V DC), os seccionadores fornecem desconex\u00e3o vis\u00edvel\u2014uma folga f\u00edsica que voc\u00ea pode ver ou verificar\u2014entre condutores energizados e equipamentos downstream.<\/p>\n<p>Ao contr\u00e1rio de <a href=\"https:\/\/test.viox.com\/pt\/circuit-breaker-vs-isolator-switch\/\">disjuntores<\/a>, os seccionadores n\u00e3o s\u00e3o projetados para interromper correntes de falta sob carga. Eles s\u00e3o desconectores de manuten\u00e7\u00e3o. Voc\u00ea os abre quando o circuito est\u00e1 desenergizado ou transportando carga m\u00ednima, criando um ponto de isolamento seguro para o trabalho downstream. A maioria dos seccionadores inclui um mecanismo de bloqueio (haste de cadeado ou al\u00e7a trav\u00e1vel) para conformidade com LOTO (Lockout\/Tagout).<\/p>\n<p>Aqui est\u00e1 o que torna a sele\u00e7\u00e3o do seccionador cr\u00edtica: a f\u00edsica da <strong>interrup\u00e7\u00e3o do arco<\/strong>\u2014 o que acontece nos microssegundos ap\u00f3s voc\u00ea abrir o interruptor \u2014 \u00e9 fundamentalmente diferente para CA vs CC. Um seccionador adequado para servi\u00e7o CA pode ser completamente inadequado (e perigoso) para servi\u00e7o CC, mesmo em tens\u00e3o mais baixa. A placa de identifica\u00e7\u00e3o pode dizer \u201c690V\u201d, mas isso \u00e9 690V <em>AC<\/em>. Us\u00e1-lo em uma string solar de 600V CC? Voc\u00ea acabou de criar um potencial risco de arco el\u00e9trico.<\/p>\n<p>Este n\u00e3o \u00e9 um detalhe t\u00e9cnico menor ou uma margem de seguran\u00e7a conservadora. \u00c9 f\u00edsica. E entender o porqu\u00ea requer olhar para o que acontece dentro de cada interruptor quando os contatos se separam sob tens\u00e3o.<\/p>\n<p><strong>Dica #1:<\/strong> Nunca use um seccionador classificado para CA para aplica\u00e7\u00f5es CC, a menos que ele tenha classifica\u00e7\u00f5es expl\u00edcitas de tens\u00e3o\/corrente CC em sua folha de dados. Um seccionador classificado para 690V CA normalmente tem capacidade CC de apenas 220-250V CC \u2014 menos do que uma string solar de 4 pain\u00e9is em circuito aberto.<\/p>\n<h2>O Problema da Extin\u00e7\u00e3o do Arco: Por Que CC \u00c9 Diferente<\/h2>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-20304\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/viox-isolator-principle.svg\" alt=\"VIOX Isolator Switch Principle\" width=\"800\" height=\"680\" \/><\/p>\n<p>Quando voc\u00ea abre qualquer interruptor sob tens\u00e3o, um arco se forma. \u00c9 inevit\u00e1vel. \u00c0 medida que os contatos se separam, a lacuna entre eles ainda \u00e9 pequena o suficiente \u2014 micr\u00f4metros, depois mil\u00edmetros \u2014 para que a tens\u00e3o ionize o ar, criando um canal de plasma condutor. A corrente continua a fluir atrav\u00e9s deste arco, mesmo que os contatos mec\u00e2nicos n\u00e3o estejam mais tocando.<\/p>\n<p>Para que o interruptor realmente isole o circuito, este arco deve ser <strong>extinto<\/strong>. E aqui \u00e9 onde CA e CC divergem completamente.<\/p>\n<h3>CA: A Passagem por Zero Natural<\/h3>\n<p>A corrente alternada, como o pr\u00f3prio nome sugere, alterna. Um sistema CA de 50 Hz cruza a tens\u00e3o\/corrente zero 100 vezes por segundo. Um sistema de 60 Hz cruza zero 120 vezes por segundo. A cada 8,33 milissegundos (60 Hz) ou 10 milissegundos (50 Hz), o fluxo de corrente inverte a dire\u00e7\u00e3o \u2014 e passa por zero.<\/p>\n<p>Na passagem por zero da corrente, n\u00e3o h\u00e1 energia sustentando o arco. O plasma desioniza. O arco se extingue. Se os contatos se separaram o suficiente no pr\u00f3ximo meio ciclo, a rigidez diel\u00e9trica da lacuna (sua capacidade de suportar tens\u00e3o sem reigni\u00e7\u00e3o) excede a tens\u00e3o do sistema. O arco n\u00e3o re-ignita. O isolamento \u00e9 alcan\u00e7ado.<\/p>\n<p>This is <strong>\u201cA Rede de Seguran\u00e7a da Passagem por Zero.\u201d<\/strong> Os seccionadores CA podem confiar nesta interrup\u00e7\u00e3o natural. Seu design de contato, dist\u00e2ncia da lacuna e geometria da c\u00e2mara de arco s\u00f3 precisam garantir que o arco n\u00e3o re-ignite ap\u00f3s a pr\u00f3xima passagem por zero. \u00c9 um problema de design relativamente tolerante.<\/p>\n<h3>CC: O Problema do Arco Infinito<\/h3>\n<p>A corrente cont\u00ednua n\u00e3o tem passagens por zero. Nunca. Uma string solar de 600V CC fornece 600 volts continuamente. Quando os contatos do seccionador se separam e um arco se forma, esse arco \u00e9 sustentado por energia cont\u00ednua. N\u00e3o h\u00e1 ponto de interrup\u00e7\u00e3o natural. O arco continuar\u00e1 indefinidamente at\u00e9 que uma de tr\u00eas coisas aconte\u00e7a:<\/p>\n<ol>\n<li><strong>A lacuna de contato se torna grande o suficiente<\/strong> para que mesmo o arco n\u00e3o consiga preench\u00ea-la (requerendo uma separa\u00e7\u00e3o f\u00edsica muito maior do que CA)<\/li>\n<li><strong>O arco \u00e9 mecanicamente esticado, resfriado e soprado para fora<\/strong> usando campos magn\u00e9ticos e c\u00e2maras de extin\u00e7\u00e3o de arco<\/li>\n<li><strong>Os contatos se soldam<\/strong> devido ao aquecimento sustentado, derrotando todo o prop\u00f3sito do isolamento<\/li>\n<\/ol>\n<p>A op\u00e7\u00e3o 3 \u00e9 o que acontece quando voc\u00ea usa um seccionador classificado para CA em servi\u00e7o CC. A velocidade de separa\u00e7\u00e3o do contato e a dist\u00e2ncia da lacuna que funcionam bem para CA \u2014 porque a pr\u00f3xima passagem por zero chega em 10 milissegundos \u2014 s\u00e3o insuficientes para CC. O arco se mant\u00e9m. A eros\u00e3o do contato acelera. No pior caso, os contatos soldam e voc\u00ea perde o isolamento completamente.<\/p>\n<p><strong>Dica #2:<\/strong> A corrente CA cruza zero 100 vezes por segundo (50 Hz) ou 120 vezes (60 Hz) \u2014 cada passagem por zero \u00e9 uma oportunidade para o arco se extinguir naturalmente. A corrente CC nunca cruza zero. Esta n\u00e3o \u00e9 uma diferen\u00e7a menor \u2014 \u00e9 por isso que os seccionadores CC precisam de bobinas de sopro magn\u00e9tico e c\u00e2maras de extin\u00e7\u00e3o de arco profundas que os seccionadores CA n\u00e3o precisam.<\/p>\n<figure><img decoding=\"async\" class=\"alignnone size-full wp-image-20305\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/AC-vs-DC-Arc-Extinction-Mechanisms.webp\" alt=\"AC vs DC Arc Extinction Mechanisms\" width=\"800\" height=\"450\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/AC-vs-DC-Arc-Extinction-Mechanisms.webp 800w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/AC-vs-DC-Arc-Extinction-Mechanisms-300x169.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/AC-vs-DC-Arc-Extinction-Mechanisms-768x432.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/AC-vs-DC-Arc-Extinction-Mechanisms-18x10.webp 18w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/AC-vs-DC-Arc-Extinction-Mechanisms-600x338.webp 600w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><figcaption>Figura 1: Mecanismos de Extin\u00e7\u00e3o de Arco CA vs CC. A corrente CA cruza zero 100-120 vezes por segundo, fornecendo pontos de interrup\u00e7\u00e3o de arco naturais. A corrente CC nunca cruza zero \u2014 os arcos se mant\u00eam continuamente at\u00e9 serem extintos mecanicamente.<\/figcaption><\/figure>\n<h2>Design do Seccionador CC: O Guerreiro da C\u00e2mara de Arco<\/h2>\n<p>Como os arcos CC n\u00e3o se autoextinguem, os seccionadores CC devem for\u00e7ar a extin\u00e7\u00e3o por meios mec\u00e2nicos agressivos. Este \u00e9 <strong>\u201cO Guerreiro da C\u00e2mara de Arco\u201d<\/strong>\u2014 um seccionador CC \u00e9 projetado para a batalha.<\/p>\n<h3>Bobinas de Sopro Magn\u00e9tico<\/h3>\n<p>A maioria dos seccionadores CC incorpora <strong>bobinas de sopro magn\u00e9tico<\/strong> ou \u00edm\u00e3s permanentes posicionados perto dos contatos. Quando um arco se forma, o campo magn\u00e9tico interage com a corrente do arco (que \u00e9 uma carga em movimento), produzindo uma for\u00e7a de Lorentz que empurra o arco para longe dos contatos e para dentro da c\u00e2mara de extin\u00e7\u00e3o de arco.<\/p>\n<p>Pense nisso como uma m\u00e3o magn\u00e9tica que fisicamente empurra o arco para longe de onde ele quer ficar. Quanto mais r\u00e1pido e mais longe voc\u00ea move o arco, mais ele esfria e estica, at\u00e9 que n\u00e3o consiga mais se sustentar.<\/p>\n<h3>C\u00e2maras de Extin\u00e7\u00e3o de Arco (Placas Divisoras)<\/h3>\n<p>Uma vez que o arco \u00e9 soprado para dentro da c\u00e2mara de arco, ele encontra <strong>c\u00e2maras de extin\u00e7\u00e3o de arco<\/strong>\u2014 conjuntos de placas de metal (geralmente cobre) que dividem o arco em m\u00faltiplos segmentos mais curtos. Cada segmento tem sua pr\u00f3pria queda de tens\u00e3o. Quando a queda de tens\u00e3o total em todos os segmentos excede a tens\u00e3o do sistema, o arco n\u00e3o consegue mais se sustentar. Ele colapsa.<\/p>\n<p>Os seccionadores CC usam designs de c\u00e2maras de extin\u00e7\u00e3o de arco mais profundos e agressivos do que os seccionadores CA porque n\u00e3o podem confiar nas passagens por zero da corrente. O arco deve ser extinto \u00e0 for\u00e7a com corrente total, sempre.<\/p>\n<h3>Materiais de Contato com Alto Teor de Prata<\/h3>\n<p>Os arcos CC s\u00e3o brutais nos contatos. O arqueamento sustentado em tens\u00e3o total causa eros\u00e3o e aquecimento r\u00e1pidos. Para suportar isso, os seccionadores CC usam materiais de contato com maior teor de prata (geralmente ligas de prata-tungst\u00eanio ou prata-n\u00edquel) que resistem \u00e0 soldagem e eros\u00e3o melhor do que os contatos de cobre ou lat\u00e3o comuns em seccionadores CA.<\/p>\n<p>O resultado? Um seccionador CC classificado para 1000V CC a 32A \u00e9 fisicamente maior, mais pesado, mais complexo e custa 2-3\u00d7 mais do que um seccionador CA com classifica\u00e7\u00e3o semelhante. Este n\u00e3o \u00e9 um pre\u00e7o arbitr\u00e1rio \u2014 \u00e9 o custo de engenharia de for\u00e7ar a extin\u00e7\u00e3o do arco sem uma passagem por zero.<\/p>\n<p><strong>Dica #3:<\/strong> Para sistemas fotovoltaicos, sempre verifique se a classifica\u00e7\u00e3o de tens\u00e3o DC do isolador excede a tens\u00e3o m\u00e1xima de circuito aberto (Voc) da sua string na temperatura mais baixa esperada. Uma string de 10 pain\u00e9is de m\u00f3dulos de 400W pode atingir 500-600V DC a -10\u00b0C\u2014excedendo muitos isoladores \u201ccompat\u00edveis com DC\u201d. Consulte tamb\u00e9m nosso guia sobre <a href=\"https:\/\/test.viox.com\/pt\/connection-of-dc-isolators\/\">Conex\u00e3o de Isoladores DC<\/a> para pr\u00e1ticas de fia\u00e7\u00e3o seguras.<\/p>\n<figure><\/figure>\n<figure><div id='gallery-1' class='gallery galleryid-19015 gallery-columns-3 gallery-size-full'><figure class='gallery-item'>\n\t\t\t<div class='gallery-icon landscape'>\n\t\t\t\t<a href='https:\/\/test.viox.com\/pt\/?attachment_id=14986'><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"800\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VOPV-DC-Isolator-Switch-NL1_T-Series-1.webp\" class=\"attachment-full size-full\" alt=\"VOPV DC Isolator Switch NL1_T Series\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VOPV-DC-Isolator-Switch-NL1_T-Series-1.webp 800w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VOPV-DC-Isolator-Switch-NL1_T-Series-1-300x300.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VOPV-DC-Isolator-Switch-NL1_T-Series-1-150x150.webp 150w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VOPV-DC-Isolator-Switch-NL1_T-Series-1-768x768.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VOPV-DC-Isolator-Switch-NL1_T-Series-1-12x12.webp 12w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VOPV-DC-Isolator-Switch-NL1_T-Series-1-600x600.webp 600w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VOPV-DC-Isolator-Switch-NL1_T-Series-1-100x100.webp 100w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/elementor\/thumbs\/VOPV-DC-Isolator-Switch-NL1_T-Series-1-r3ntkz9aljrq1yjgy0uif02c7rkuczs5lic1glcknc.webp 500w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/a>\n\t\t\t<\/div><\/figure><figure class='gallery-item'>\n\t\t\t<div class='gallery-icon landscape'>\n\t\t\t\t<a href='https:\/\/test.viox.com\/pt\/?attachment_id=14983'><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"800\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VOPV-DC-Isolator-Switch-NL1_T-Series.webp\" class=\"attachment-full size-full\" alt=\"VOPV DC Isolator Switch NL1 Series\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VOPV-DC-Isolator-Switch-NL1_T-Series.webp 800w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VOPV-DC-Isolator-Switch-NL1_T-Series-300x300.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VOPV-DC-Isolator-Switch-NL1_T-Series-150x150.webp 150w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VOPV-DC-Isolator-Switch-NL1_T-Series-768x768.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VOPV-DC-Isolator-Switch-NL1_T-Series-12x12.webp 12w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VOPV-DC-Isolator-Switch-NL1_T-Series-600x600.webp 600w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VOPV-DC-Isolator-Switch-NL1_T-Series-100x100.webp 100w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/a>\n\t\t\t<\/div><\/figure><figure class='gallery-item'>\n\t\t\t<div class='gallery-icon landscape'>\n\t\t\t\t<a href='https:\/\/test.viox.com\/pt\/vopv-dc-isolator-switch-l2-series\/'><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"800\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VOPV-DC-Isolator-Switch-L2-Series.webp\" class=\"attachment-full size-full\" alt=\"VOPV DC Isolator Switch L2 Series\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VOPV-DC-Isolator-Switch-L2-Series.webp 800w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VOPV-DC-Isolator-Switch-L2-Series-300x300.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VOPV-DC-Isolator-Switch-L2-Series-150x150.webp 150w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VOPV-DC-Isolator-Switch-L2-Series-768x768.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VOPV-DC-Isolator-Switch-L2-Series-12x12.webp 12w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VOPV-DC-Isolator-Switch-L2-Series-600x600.webp 600w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VOPV-DC-Isolator-Switch-L2-Series-100x100.webp 100w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/a>\n\t\t\t<\/div><\/figure>\n\t\t<\/div>\n<figcaption>Figura 2: <a href=\"https:\/\/test.viox.com\/pt\/dc-isolator-switch\/\">Produto Seccionador CC Real<\/a>. Este seccionador CC industrial classificado para 1000V CC e 32A mostra a constru\u00e7\u00e3o substancial necess\u00e1ria para aplica\u00e7\u00f5es fotovoltaicas.<\/figcaption><\/figure>\n<h2>Design do Seccionador CA: Cavalgando a Passagem por Zero<\/h2>\n<p>Os seccionadores CA s\u00e3o, em compara\u00e7\u00e3o, simples. Eles n\u00e3o precisam de bobinas de sopro magn\u00e9tico (embora alguns os incluam para interrup\u00e7\u00e3o mais r\u00e1pida). Eles n\u00e3o precisam de c\u00e2maras de extin\u00e7\u00e3o de arco profundas. Eles n\u00e3o precisam de materiais de contato ex\u00f3ticos.<\/p>\n<p>Por qu\u00ea? Porque <strong>a passagem por zero faz a maior parte do trabalho<\/strong>. O trabalho do seccionador CA n\u00e3o \u00e9 extinguir o arco \u00e0 for\u00e7a \u2014 \u00e9 garantir que o arco n\u00e3o re-ignite ap\u00f3s a interrup\u00e7\u00e3o natural da passagem por zero.<\/p>\n<ul>\n<li><strong>Dist\u00e2ncia de lacuna suficiente:<\/strong> Tipicamente 3-6mm para CA de baixa tens\u00e3o, dependendo da tens\u00e3o e do grau de polui\u00e7\u00e3o<\/li>\n<li><strong>Conten\u00e7\u00e3o b\u00e1sica do arco:<\/strong> Barreiras isolantes simples para evitar o trilhamento de arco sobre as superf\u00edcies<\/li>\n<\/ul>\n<p>\u00c9 isso. Os isoladores AC dependem da forma de onda para fazer o trabalho pesado. O design mec\u00e2nico s\u00f3 precisa acompanhar. Para aplica\u00e7\u00f5es espec\u00edficas, como motores trif\u00e1sicos, consulte nosso <a href=\"https:\/\/test.viox.com\/pt\/complete-guide-to-3-phase-isolator-switch\/\">Guia Completo para Seccionador Trif\u00e1sico<\/a>.<\/p>\n<figure><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-20308 aligncenter\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/ac-isolator-switch.webp\" alt=\"ac isolator switch\" width=\"353\" height=\"446\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/ac-isolator-switch.webp 806w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/ac-isolator-switch-238x300.webp 238w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/ac-isolator-switch-768x970.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/ac-isolator-switch-10x12.webp 10w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/ac-isolator-switch-600x758.webp 600w\" sizes=\"(max-width: 353px) 100vw, 353px\" \/><figcaption>Figura 4: Design do Isolador AC (Aproveitando a Passagem por Zero). Este isolador AC trif\u00e1sico mostra uma constru\u00e7\u00e3o externa dramaticamente mais simples\u2014sem complexidade vis\u00edvel da c\u00e2mara de arco.<\/figcaption><\/figure>\n<h2>A Penalidade de Redu\u00e7\u00e3o da Tens\u00e3o<\/h2>\n<p>Aqui est\u00e1 uma surpresa que pega muitos engenheiros: se voc\u00ea <em>deve<\/em> usar um isolador com classifica\u00e7\u00e3o AC para DC (o que voc\u00ea n\u00e3o deveria, mas hipoteticamente), sua capacidade de tens\u00e3o DC \u00e9 dramaticamente menor do que sua classifica\u00e7\u00e3o AC. Isso \u00e9 <strong>\u201cA Penalidade de Redu\u00e7\u00e3o da Tens\u00e3o.\u201d<\/strong><\/p>\n<p>Um padr\u00e3o t\u00edpico:<\/p>\n<ul>\n<li>Classifica\u00e7\u00e3o de 690V AC \u2192 capacidade de aproximadamente 220-250V DC<\/li>\n<li>Classifica\u00e7\u00e3o de 400V AC \u2192 capacidade de aproximadamente 150-180V DC<\/li>\n<li>Classifica\u00e7\u00e3o de 230V AC \u2192 capacidade de aproximadamente 80-110V DC<\/li>\n<\/ul>\n<p>Por que uma redu\u00e7\u00e3o t\u00e3o severa? Porque a tens\u00e3o do arco DC \u00e9 fundamentalmente diferente da tens\u00e3o do arco AC. Os fabricantes levam isso em conta, reduzindo drasticamente a classifica\u00e7\u00e3o de tens\u00e3o DC.<\/p>\n<p>Para aplica\u00e7\u00f5es solares fotovoltaicas, isso \u00e9 <strong>\u201cA Armadilha da String PV.\u201d<\/strong> Um painel solar comum de 400W tem uma tens\u00e3o de circuito aberto (Voc) de aproximadamente 48-50V em STC. Junte 10 pain\u00e9is em s\u00e9rie: 480-500V. Mas a Voc aumenta em temperaturas mais baixas. Um isolador AC de 400V com uma classifica\u00e7\u00e3o DC de 180V? Completamente inadequado.<\/p>\n<p><strong>Dica #4:<\/strong> Os isoladores s\u00e3o projetados para comuta\u00e7\u00e3o sem carga ou com carga m\u00ednima\u2014s\u00e3o desconex\u00f5es de manuten\u00e7\u00e3o, n\u00e3o prote\u00e7\u00e3o contra sobrecorrente. Para ambientes que exigem prote\u00e7\u00e3o contra intemp\u00e9ries, certifique-se de entender <a href=\"https:\/\/test.viox.com\/pt\/indoor-outdoor-isolator-switch-ip-ratings\/\">Classifica\u00e7\u00f5es IP para seccionadores<\/a>.<\/p>\n<figure><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-20307\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/The-Voltage-Derating-Penalty-graph.webp\" alt=\"The Voltage Derating Penalty graph\" width=\"800\" height=\"450\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/The-Voltage-Derating-Penalty-graph.webp 800w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/The-Voltage-Derating-Penalty-graph-300x169.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/The-Voltage-Derating-Penalty-graph-768x432.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/The-Voltage-Derating-Penalty-graph-18x10.webp 18w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/The-Voltage-Derating-Penalty-graph-600x338.webp 600w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><figcaption>Figura 5: A Penalidade de Redu\u00e7\u00e3o da Tens\u00e3o. Os isoladores com classifica\u00e7\u00e3o AC perdem 60-70% de sua capacidade de tens\u00e3o quando usados para aplica\u00e7\u00f5es DC.<\/figcaption><\/figure>\n<h2>Isolador DC vs AC: Especifica\u00e7\u00f5es Chave Comparadas<\/h2>\n<table border=\"1\" cellspacing=\"0\" cellpadding=\"10\">\n<thead>\n<tr>\n<th>Especifica\u00e7\u00e3o<\/th>\n<th>Isolador CA<\/th>\n<th>Isolador DC<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>Mecanismo de Extin\u00e7\u00e3o de Arco<\/strong><\/td>\n<td>Passagem por zero de corrente natural (100-120 vezes\/seg)<\/td>\n<td>Extin\u00e7\u00e3o mec\u00e2nica for\u00e7ada (sopro magn\u00e9tico + c\u00e2maras de extin\u00e7\u00e3o de arco)<\/td>\n<\/tr>\n<tr>\n<td><strong>Dist\u00e2ncia de Contato Necess\u00e1ria<\/strong><\/td>\n<td>3-6mm (varia conforme a tens\u00e3o)<\/td>\n<td>8-15mm (dist\u00e2ncia maior para a mesma tens\u00e3o)<\/td>\n<\/tr>\n<tr>\n<td><strong>Design da C\u00e2mara de Extin\u00e7\u00e3o de Arco<\/strong><\/td>\n<td>M\u00ednimo ou nenhum<\/td>\n<td>Placas divisoras profundas, geometria agressiva<\/td>\n<\/tr>\n<tr>\n<td><strong>Sopro Magn\u00e9tico<\/strong><\/td>\n<td>Opcional (para interrup\u00e7\u00e3o r\u00e1pida)<\/td>\n<td>Obrigat\u00f3rio (\u00edm\u00e3s permanentes ou bobinas)<\/td>\n<\/tr>\n<tr>\n<td><strong>Material de contato<\/strong><\/td>\n<td>Cobre, lat\u00e3o, ligas padr\u00e3o<\/td>\n<td>Alto teor de prata (ligas Ag-W, Ag-Ni)<\/td>\n<\/tr>\n<tr>\n<td><strong>Exemplo de Classifica\u00e7\u00e3o de Tens\u00e3o<\/strong><\/td>\n<td>690V AC<\/td>\n<td>1000V DC ou 1500V DC<\/td>\n<\/tr>\n<tr>\n<td><strong>Exemplo de Classifica\u00e7\u00e3o de Corrente<\/strong><\/td>\n<td>32A, 63A, 125A t\u00edpico<\/td>\n<td>16A-1600A (faixa mais ampla para PV\/ESS)<\/td>\n<\/tr>\n<tr>\n<td><strong>Aplica\u00e7\u00f5es T\u00edpicas<\/strong><\/td>\n<td>Controle de motor, HVAC, distribui\u00e7\u00e3o AC industrial<\/td>\n<td>Solar PV, armazenamento de bateria, carregamento de EV, microredes DC<\/td>\n<\/tr>\n<tr>\n<td><strong>Normas<\/strong><\/td>\n<td>IEC 60947-3:2020 (categorias de utiliza\u00e7\u00e3o AC)<\/td>\n<td>IEC 60947-3:2020 (categorias de utiliza\u00e7\u00e3o DC: DC-21B, DC-PV2)<\/td>\n<\/tr>\n<tr>\n<td><strong>Tamanho E Peso<\/strong><\/td>\n<td>Compacto, leve<\/td>\n<td>Maior, mais pesado (2-3\u00d7 o tamanho para a mesma classifica\u00e7\u00e3o de corrente)<\/td>\n<\/tr>\n<tr>\n<td><strong>Custo<\/strong><\/td>\n<td>Menor (linha de base)<\/td>\n<td>2-3\u00d7 mais caro<\/td>\n<\/tr>\n<tr>\n<td><strong>Dura\u00e7\u00e3o do Arco na Abertura<\/strong><\/td>\n<td>&lt;10ms (at\u00e9 a pr\u00f3xima passagem por zero)<\/td>\n<td>Cont\u00ednuo at\u00e9 ser extinto mecanicamente<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Principais conclus\u00f5es:<\/strong> A \u201cpenalidade de custo de 2-3\u00d7\u201d para isoladores DC n\u00e3o \u00e9 especula\u00e7\u00e3o de pre\u00e7os\u2014reflete o imposto fundamental da f\u00edsica de extinguir arcos sem passagens por zero.<\/p>\n<h2>Quando Usar Isoladores DC vs AC<\/h2>\n<p>A decis\u00e3o n\u00e3o \u00e9 sobre prefer\u00eancia ou otimiza\u00e7\u00e3o de custos\u2014\u00e9 sobre combinar a capacidade de extin\u00e7\u00e3o de arco do isolador com o tipo de corrente do seu sistema.<\/p>\n<h3>Use Isoladores DC Para:<\/h3>\n<p><strong>1. Sistemas Solares Fotovoltaicos (PV)<\/strong><br \/>\nCada string DC de painel solar requer isolamento entre o painel e o inversor. As tens\u00f5es da string geralmente atingem 600-1000V DC. Procure a categoria de utiliza\u00e7\u00e3o IEC 60947-3 DC-PV2 projetada especificamente para servi\u00e7o de comuta\u00e7\u00e3o FV. Consulte nosso guia sobre <a href=\"https:\/\/test.viox.com\/pt\/solar-combiner-box-voltage-ratings-600v-vs-1000v-vs-1500v\/\">Classifica\u00e7\u00f5es de Tens\u00e3o da Caixa de Jun\u00e7\u00e3o Solar<\/a> para mais detalhes.<\/p>\n<p><strong>2. Sistemas de Armazenamento de Energia em Bateria (ESS)<\/strong><br \/>\nOs bancos de baterias operam em tens\u00f5es DC que variam de 48V a 800V+. O isolamento \u00e9 necess\u00e1rio entre os m\u00f3dulos de bateria e os inversores.<\/p>\n<p><strong>3. Infraestrutura de Carregamento de EV<\/strong><br \/>\nOs carregadores r\u00e1pidos DC fornecem 400-800V DC diretamente para as baterias dos ve\u00edculos.<\/p>\n<p><strong>4. Microredes DC e Data Centers<\/strong><br \/>\nOs data centers usam cada vez mais a distribui\u00e7\u00e3o de 380V DC para reduzir as perdas de convers\u00e3o.<\/p>\n<p><strong>5. Distribui\u00e7\u00e3o DC Marinha e Ferrovi\u00e1ria<\/strong><br \/>\nNavios e trens usam distribui\u00e7\u00e3o DC (24V, 48V, 110V, 750V) h\u00e1 d\u00e9cadas.<\/p>\n<h3>Use Isoladores AC Para:<\/h3>\n<p><strong>1. Circuitos de Controle de Motor<\/strong><br \/>\nIsolamento para motores de indu\u00e7\u00e3o AC, sistemas HVAC e bombas.<\/p>\n<p><strong>2. Distribui\u00e7\u00e3o CA em Edif\u00edcios<\/strong><br \/>\nIsolamento para pain\u00e9is de ilumina\u00e7\u00e3o e cargas gerais do edif\u00edcio.<\/p>\n<p><strong>3. Pain\u00e9is de Controlo CA Industriais<\/strong><br \/>\nArm\u00e1rios de controlo de m\u00e1quinas com <a href=\"https:\/\/test.viox.com\/pt\/ac-contactor\/\">Contactores AC<\/a> e PLCs.<\/p>\n<h3>A Regra Cr\u00edtica<\/h3>\n<p>Se a tens\u00e3o do seu sistema for CC \u2014 mesmo 48V CC \u2014 use um isolador com classifica\u00e7\u00e3o CC. A f\u00edsica do arco n\u00e3o se importa com o n\u00edvel de tens\u00e3o; importa-se com o tipo de forma de onda. Um arco de 48V CC ainda pode sustentar e causar soldadura de contacto num interruptor apenas CA.<\/p>\n<figure><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-20306\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/DC-Isolator-in-Solar-PV-Application.webp\" alt=\"DC Isolator in Solar PV Application\" width=\"700\" height=\"467\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/DC-Isolator-in-Solar-PV-Application.webp 700w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/DC-Isolator-in-Solar-PV-Application-300x200.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/DC-Isolator-in-Solar-PV-Application-18x12.webp 18w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/DC-Isolator-in-Solar-PV-Application-600x400.webp 600w\" sizes=\"(max-width: 700px) 100vw, 700px\" \/><figcaption>Figura 6: Isolador CC em Aplica\u00e7\u00e3o Solar FV (Contexto do Mundo Real). Esta caixa de combina\u00e7\u00e3o aberta mostra interruptores de isolamento CC, fus\u00edveis, barramentos e cablagem de conectores em implementa\u00e7\u00e3o real no terreno.<\/figcaption><\/figure>\n<h2>Guia de Sele\u00e7\u00e3o: M\u00e9todo de 4 Passos para Isoladores CC<\/h2>\n<h3>Passo 1: Calcular a Tens\u00e3o M\u00e1xima do Sistema<\/h3>\n<p>Para <strong>Solar FV:<\/strong> Calcular Voc da string na temperatura ambiente mais baixa esperada. Voc aumenta aproximadamente 0,3-0,4% por \u00b0C abaixo de 25\u00b0C.<\/p>\n<ul>\n<li>Exemplo: String de 10 pain\u00e9is, Voc = 49V\/painel em STC. A -10\u00b0C: 49V \u00d7 1,14 (fator de temperatura) \u00d7 10 pain\u00e9is = <strong>Classifica\u00e7\u00e3o m\u00ednima do isolador de 559V CC<\/strong><\/li>\n<\/ul>\n<p><strong>Pro-Tip:<\/strong> Especifique sempre a classifica\u00e7\u00e3o de tens\u00e3o do isolador pelo menos 20% acima da tens\u00e3o m\u00e1xima calculada do sistema para margem de seguran\u00e7a.<\/p>\n<h3>Passo 2: Determinar a Classifica\u00e7\u00e3o de Corrente<\/h3>\n<p>Para <strong>Solar FV:<\/strong> Use a corrente de curto-circuito da string (Isc) \u00d7 1,25 fator de seguran\u00e7a.<\/p>\n<h3>Passo 3: Verificar a Categoria de Utiliza\u00e7\u00e3o<\/h3>\n<p>Verifique a folha de dados para a categoria de utiliza\u00e7\u00e3o IEC 60947-3: DC-21B para circuitos CC gerais, DC-PV2 especificamente para comuta\u00e7\u00e3o CC fotovoltaica.<\/p>\n<h3>Passo 4: Confirmar a Classifica\u00e7\u00e3o de Curto-Circuito (Se Aplic\u00e1vel)<\/h3>\n<p>A maioria dos isoladores s\u00e3o projetados para comuta\u00e7\u00e3o sem carga ou com carga m\u00ednima. Para comuta\u00e7\u00e3o de carga regular ou interrup\u00e7\u00e3o de falhas, especifique um <a href=\"https:\/\/test.viox.com\/pt\/dc-isolator-vs-dc-circuit-breaker-complete-comparison-guide\/\">Disjuntor CC<\/a> em vez disso.<\/p>\n<p><strong>Dica Profissional:<\/strong> Os isoladores CC custam 2-3\u00d7 mais do que os isoladores CA equivalentes porque requerem materiais de contacto fundamentalmente diferentes, sistemas de extin\u00e7\u00e3o magn\u00e9tica e c\u00e2maras de extin\u00e7\u00e3o de arco profundas.<\/p>\n<h2>Perguntas Frequentes<\/h2>\n<div>\n<div>\n<h3>Posso usar um isolador CA para aplica\u00e7\u00f5es CC?<\/h3>\n<div>\n<div>\n<p>N\u00e3o, geralmente n\u00e3o pode. Os isoladores AC dependem da \u201cpassagem por zero\u201d da corrente alternada para extinguir arcos el\u00e9tricos. A corrente DC n\u00e3o tem passagem por zero, o que significa que os arcos podem se sustentar indefinidamente em um interruptor AC, levando a superaquecimento, inc\u00eandio e soldagem de contato.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<div>\n<h3>Por que os isoladores DC s\u00e3o maiores que os isoladores AC?<\/h3>\n<div>\n<div>\n<p>Os isoladores DC requerem componentes internos maiores, como bobinas de sopro magn\u00e9tico e c\u00e2maras de extin\u00e7\u00e3o de arco mais profundas (placas divisoras), para for\u00e7ar mecanicamente a extin\u00e7\u00e3o do arco. Eles tamb\u00e9m exigem folgas de contato mais amplas para evitar que o arco se restabele\u00e7a.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<div>\n<h3>Qual \u00e9 a diferen\u00e7a entre um isolador DC e um disjuntor DC?<\/h3>\n<div>\n<div>\n<p>Um isolador DC \u00e9 projetado principalmente para desconex\u00e3o de manuten\u00e7\u00e3o (isolamento do circuito) e geralmente \u00e9 operado sem carga. Um <a href=\"https:\/\/test.viox.com\/pt\/what-is-a-dc-circuit-breaker\/\">Disjuntor CC<\/a> fornece prote\u00e7\u00e3o autom\u00e1tica contra sobrecargas e curtos-circuitos e \u00e9 projetado para interromper correntes de falta sob carga.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<h2>Conclus\u00e3o: A F\u00edsica N\u00e3o \u00c9 Opcional<\/h2>\n<p>A diferen\u00e7a entre interruptores de isolamento CC e CA n\u00e3o \u00e9 uma quest\u00e3o de classifica\u00e7\u00f5es, custo ou prefer\u00eancia. \u00c9 f\u00edsica.<\/p>\n<p>Os isoladores CA dependem de <strong>\u201cA Rede de Seguran\u00e7a da Passagem por Zero\u201d<\/strong>. Os isoladores CC enfrentam <strong>\u201cO Problema do Arco Infinito\u201d<\/strong>. O arco ir\u00e1 sustentar-se indefinidamente a menos que o interruptor force a extin\u00e7\u00e3o atrav\u00e9s de bobinas de extin\u00e7\u00e3o magn\u00e9tica e calhas de arco profundas.<\/p>\n<p>Quando especifica um isolador para uma string solar FV ou armazenamento de bateria, est\u00e1 a selecionar um sistema de extin\u00e7\u00e3o de arco. Use o errado e arrisca-se a arcos sustentados e inc\u00eandio. A regra \u00e9 simples: Se a sua tens\u00e3o \u00e9 CC, use um isolador com classifica\u00e7\u00e3o CC.<\/p>\n<p>A f\u00edsica n\u00e3o \u00e9 negoci\u00e1vel. Escolha em conformidade.<\/p>\n<hr \/>\n<p><strong>Precisa de ajuda para selecionar isoladores CC para o seu projeto solar FV ou de armazenamento de bateria?<\/strong> Contacte a nossa equipa de engenharia de aplica\u00e7\u00e3o para orienta\u00e7\u00e3o t\u00e9cnica sobre solu\u00e7\u00f5es de comuta\u00e7\u00e3o CC em conformidade com a norma IEC 60947-3.<\/p>\n<\/div>\n<div class=\"simg-pop-btn\" style=\"top: 466.914px; left: 14px; display: none;\"><\/div>\n<div class=\"simg-pop-btn\" style=\"top: 466.914px; left: 14px; display: none;\"><\/div>\n<div class=\"simg-pop-btn\" style=\"top: 653.914px; left: 14px; display: none;\"><\/div>\n<div class=\"simg-pop-btn\" style=\"top: 653.914px; left: 14px; display: none;\"><\/div>","protected":false},"excerpt":{"rendered":"<p>Key Takeaways Zero-Crossing Factor: AC current naturally extinguishes arcs at zero-crossings (100-120 times\/sec), while DC current sustains arcs continuously. Design Differences: DC isolators require magnetic blow-out coils and deep arc chutes, making them physically larger and more expensive than AC versions. Voltage Derating: Using an AC isolator for DC applications results in a significant drop [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":19023,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1],"tags":[],"class_list":["post-19015","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"_links":{"self":[{"href":"https:\/\/test.viox.com\/pt\/wp-json\/wp\/v2\/posts\/19015","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/test.viox.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/test.viox.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/test.viox.com\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/test.viox.com\/pt\/wp-json\/wp\/v2\/comments?post=19015"}],"version-history":[{"count":3,"href":"https:\/\/test.viox.com\/pt\/wp-json\/wp\/v2\/posts\/19015\/revisions"}],"predecessor-version":[{"id":21359,"href":"https:\/\/test.viox.com\/pt\/wp-json\/wp\/v2\/posts\/19015\/revisions\/21359"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/test.viox.com\/pt\/wp-json\/wp\/v2\/media\/19023"}],"wp:attachment":[{"href":"https:\/\/test.viox.com\/pt\/wp-json\/wp\/v2\/media?parent=19015"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/test.viox.com\/pt\/wp-json\/wp\/v2\/categories?post=19015"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/test.viox.com\/pt\/wp-json\/wp\/v2\/tags?post=19015"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}