{"id":2613,"date":"2024-06-13T20:04:19","date_gmt":"2024-06-13T12:04:19","guid":{"rendered":"https:\/\/viox.com\/?post_type=product&#038;p=2613"},"modified":"2024-06-13T20:05:13","modified_gmt":"2024-06-13T12:05:13","slug":"15mm-capacitive-proximity-sensor-ki0203","status":"publish","type":"product","link":"https:\/\/test.viox.com\/pl\/produkt\/15mm-capacitive-proximity-sensor-ki0203\/","title":{"rendered":"Pojemno\u015bciowy czujnik zbli\u017ceniowy 15 mm KI0203"},"content":{"rendered":"<table style=\"font-size: 16px; font-style: normal;\">\n<tbody>\n<tr class=\"firstRow\">\n<td colspan=\"2\">Model<\/td>\n<td>KI0202<\/td>\n<td>KI0203<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\"><\/td>\n<td>Funkcja wyj\u015bcia<\/td>\n<td>Normalnie otwarty<\/td>\n<td>Nominalnie blisko<\/td>\n<\/tr>\n<tr>\n<td>Zakres wykrywania (mm)<\/td>\n<td>3~15<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Obudowa<\/td>\n<td colspan=\"2\">Typ gwintowany<\/td>\n<\/tr>\n<tr>\n<td>Wymiary (mm)<\/td>\n<td colspan=\"2\">M30\u00d71,5\/L=81<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">Elektryczny<br \/>\ndata<\/td>\n<td>Napi\u0119cie robocze (V)<\/td>\n<td colspan=\"2\">20~250 AC\/DC<\/td>\n<\/tr>\n<tr>\n<td>Klasa ochrony<\/td>\n<td colspan=\"2\">\u2161<\/td>\n<\/tr>\n<tr>\n<td>Zabezpieczenie przed odwrotn\u0105 polaryzacj\u0105<\/td>\n<td colspan=\"2\">nie<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"12\"><\/td>\n<td>Funkcja wyj\u015bcia<\/td>\n<td>Nominalnie otwarte<\/td>\n<td>Nominalnie blisko<\/td>\n<\/tr>\n<tr>\n<td>Maksymalny spadek napi\u0119cia prze\u0142\u0105czania<br \/>\nwyj\u015bcie DC(V)<\/td>\n<td colspan=\"2\">8<\/td>\n<\/tr>\n<tr>\n<td>Maksymalny spadek napi\u0119cia prze\u0142\u0105czania<br \/>\nwyj\u015bcie AC(V)<\/td>\n<td colspan=\"2\">10<\/td>\n<\/tr>\n<tr>\n<td>Minimalny pr\u0105d obci\u0105\u017cenia (mA)<\/td>\n<td colspan=\"2\">5<\/td>\n<\/tr>\n<tr>\n<td>Maksymalny pr\u0105d up\u0142ywu (mA)<\/td>\n<td colspan=\"2\">2,5 (250 V AC) \/1,7 (110 V AC\uff09\/1,5 (24 V DC)<\/td>\n<\/tr>\n<tr>\n<td>Sta\u0142y pr\u0105d znamionowy<br \/>\nWyj\u015bcie prze\u0142\u0105czaj\u0105ce AC(mA)<\/td>\n<td colspan=\"2\">200; (dla aplikacji UL: 200\/100DC)<\/td>\n<\/tr>\n<tr>\n<td>Sta\u0142y pr\u0105d znamionowy<br \/>\nwyj\u015bcie prze\u0142\u0105czaj\u0105ce DC(mA)<\/td>\n<td colspan=\"2\">200; (dla aplikacji UL: 200AC\/100DC)<\/td>\n<\/tr>\n<tr>\n<td>Kr\u00f3tkotrwa\u0142y pr\u0105d znamionowy<br \/>\nwyj\u015bcie prze\u0142\u0105czaj\u0105ce (mA)<\/td>\n<td colspan=\"2\">1500;(20ms \/0,5 Hz)<\/td>\n<\/tr>\n<tr>\n<td>Cz\u0119stotliwo\u015b\u0107 prze\u0142\u0105czania AC(Hz)<\/td>\n<td colspan=\"2\">25<\/td>\n<\/tr>\n<tr>\n<td>Cz\u0119stotliwo\u015b\u0107 prze\u0142\u0105czania DC(Hz)<\/td>\n<td colspan=\"2\">40<\/td>\n<\/tr>\n<tr>\n<td>Odporno\u015b\u0107 na zwarcia<\/td>\n<td colspan=\"2\">nie<\/td>\n<\/tr>\n<tr>\n<td>Ochrona przed przeci\u0105\u017ceniem<\/td>\n<td colspan=\"2\">nie<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\">Monitorowanie<br \/>\nzakres<\/td>\n<td>Zakres wykrywania (mm)<\/td>\n<td colspan=\"2\">3~15<\/td>\n<\/tr>\n<tr>\n<td>Regulowany zakres wykrywania<\/td>\n<td colspan=\"2\">tak<\/td>\n<\/tr>\n<tr>\n<td>Zakres ustawie\u0144 fabrycznych (mm)<\/td>\n<td>3~15<\/td>\n<td>15<\/td>\n<\/tr>\n<tr>\n<td>Rzeczywisty zakres sening Sr(mm)<\/td>\n<td colspan=\"2\">15\u00b110\uff05<\/td>\n<\/tr>\n<tr>\n<td>Odleg\u0142o\u015b\u0107 robocza (mm)<\/td>\n<td colspan=\"2\">0~12.1<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">Dok\u0142adno\u015b\u0107\/odchylenia<\/td>\n<td>Wsp\u00f3\u0142czynnik koryguj\u0105cy<\/td>\n<td colspan=\"2\">szk\u0142o : 0,4 \/woda : 1\/ceramika : 0,2\/PVC :0,2<\/td>\n<\/tr>\n<tr>\n<td>Histereza (\uff05 Sr)<\/td>\n<td colspan=\"2\">1~15<\/td>\n<\/tr>\n<tr>\n<td>Dryft punktu prze\u0142\u0105czania (\uff05 Sr)<\/td>\n<td colspan=\"2\">-15-15<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">Dzia\u0142anie<br \/>\nwarunki<\/td>\n<td>Temperatura otoczenia (\u2103)<\/td>\n<td colspan=\"2\">-25~70<\/td>\n<\/tr>\n<tr>\n<td>Ochrona<\/td>\n<td colspan=\"2\">IP65<\/td>\n<\/tr>\n<tr>\n<td>Zwi\u0119kszona odporno\u015b\u0107<\/td>\n<td colspan=\"2\">tak; (zwi\u0119kszona odporno\u015b\u0107 na przewodzone zak\u0142\u00f3cenia o cz\u0119stotliwo\u015bci radiowej)<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Testy\/zatwierdzenia<\/td>\n<td>EMC<\/td>\n<td colspan=\"2\">EN 60947-5-2<\/td>\n<\/tr>\n<tr>\n<td>MTTF(lata)<\/td>\n<td colspan=\"2\">489<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"6\">Dane mechaniczne<\/td>\n<td>Waga (g)<\/td>\n<td>181.5<\/td>\n<td>181<\/td>\n<\/tr>\n<tr>\n<td>Obudowa<\/td>\n<td colspan=\"2\">Typ gwintowany<\/td>\n<\/tr>\n<tr>\n<td>Mo\u017cliwo\u015b\u0107 monta\u017cu<\/td>\n<td colspan=\"2\">mo\u017cliwo\u015b\u0107 monta\u017cu podtynkowego<\/td>\n<\/tr>\n<tr>\n<td>Wymiary (mm)<\/td>\n<td colspan=\"2\">M30\u00d71,5\/L=81<\/td>\n<\/tr>\n<tr>\n<td>Oznaczenie w\u0105tku<\/td>\n<td colspan=\"2\">M30\u00d71.5<\/td>\n<\/tr>\n<tr>\n<td>Materia\u0142<\/td>\n<td colspan=\"2\">PBT<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Wy\u015bwietlacz<\/td>\n<td>Status prze\u0142\u0105czania 1 \u00d7 LED, \u017c\u00f3\u0142ty<\/td>\n<td>Status prze\u0142\u0105czania 1 \u00d7 LED, czerwony<br \/>\nStatus prze\u0142\u0105czania 1 \u00d7 LED, czerwony<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Akcesoria<\/td>\n<td colspan=\"2\">nakr\u0119tki zabezpieczaj\u0105ce:2<br \/>\n\u015brubokr\u0119t:1<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Uwagi<\/td>\n<td>Uwagi<\/td>\n<td colspan=\"2\">Zalecenie: sprawdzi\u0107 urz\u0105dzenie pod k\u0105tem niezawodnego dzia\u0142ania po uruchomieniu obwodu.<\/td>\n<\/tr>\n<tr>\n<td>Ilo\u015b\u0107 w opakowaniu<\/td>\n<td colspan=\"2\">1 szt.<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Po\u0142\u0105czenie elektryczne<\/td>\n<td>Bezpiecznik miniaturowy zgodny z norm\u0105 IEC60127-2 arkusz 1; \u22642A;<br \/>\nszybkie dzia\u0142anie (po\u0142\u0105czenie elektryczne)<br \/>\nKabel: 2 m, PVC, 2 \u00d7 0,5 mm\u00b2 (po\u0142\u0105czenie)<\/td>\n<td>Bezpiecznik miniaturowy zgodny z norm\u0105 IEC60127-2 arkusz 1; \u22642A;<br \/>\nszybkie dzia\u0142anie<br \/>\nKabel: 2 m, PVC, 2 \u00d7 0,5 mm\u00b2<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone wp-image-2609 size-full\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/06\/15mm-capacitive-proximity-sensor-KI0206-Dimension.webp\" alt=\"\" width=\"800\" height=\"800\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/06\/15mm-capacitive-proximity-sensor-KI0206-Dimension.webp 800w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/06\/15mm-capacitive-proximity-sensor-KI0206-Dimension-300x300.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/06\/15mm-capacitive-proximity-sensor-KI0206-Dimension-150x150.webp 150w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/06\/15mm-capacitive-proximity-sensor-KI0206-Dimension-768x768.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/06\/15mm-capacitive-proximity-sensor-KI0206-Dimension-600x600.webp 600w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/06\/15mm-capacitive-proximity-sensor-KI0206-Dimension-100x100.webp 100w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>","protected":false},"excerpt":{"rendered":"<p>KI0203 to czujnik temperatury produkowany przez firm\u0119 VIOX. Wykorzystuje on termistor p\u00f3\u0142przewodnikowy jako element czujnikowy, charakteryzuj\u0105cy si\u0119 niewielkimi rozmiarami, wysok\u0105 czu\u0142o\u015bci\u0105 i du\u017c\u0105 dok\u0142adno\u015bci\u0105. Ten typ czujnika temperatury jest szeroko stosowany ze wzgl\u0119du na prosty proces produkcji i niski koszt.<\/p>","protected":false},"featured_media":2602,"comment_status":"closed","ping_status":"closed","template":"","meta":{"inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[],"product_cat":[30,77],"product_tag":[],"class_list":{"0":"post-2613","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-sensors","7":"product_cat-ultrasonic-sensors","8":"desktop-align-left","9":"tablet-align-left","10":"mobile-align-left","12":"first","13":"instock","14":"shipping-taxable","15":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/test.viox.com\/pl\/wp-json\/wp\/v2\/product\/2613","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/test.viox.com\/pl\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/test.viox.com\/pl\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/test.viox.com\/pl\/wp-json\/wp\/v2\/comments?post=2613"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/test.viox.com\/pl\/wp-json\/wp\/v2\/media\/2602"}],"wp:attachment":[{"href":"https:\/\/test.viox.com\/pl\/wp-json\/wp\/v2\/media?parent=2613"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/test.viox.com\/pl\/wp-json\/wp\/v2\/product_brand?post=2613"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/test.viox.com\/pl\/wp-json\/wp\/v2\/product_cat?post=2613"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/test.viox.com\/pl\/wp-json\/wp\/v2\/product_tag?post=2613"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}