{"id":5593,"date":"2024-09-13T16:40:35","date_gmt":"2024-09-13T08:40:35","guid":{"rendered":"https:\/\/viox.com\/?post_type=product&#038;p=5593"},"modified":"2024-09-13T16:48:44","modified_gmt":"2024-09-13T08:48:44","slug":"viox-vrc3-63-2p-25a-rccb","status":"publish","type":"product","link":"https:\/\/test.viox.com\/my\/product\/viox-vrc3-63-2p-25a-rccb\/","title":{"rendered":"VIOX VRC3-63 2P 25A RCCB"},"content":{"rendered":"<div class=\"product-intro\">\n<h2>VIOX VRC3-63 2P 25A RCCB Electronic\/Electro-Magnetic \u1021\u1019\u103b\u102d\u102f\u1038\u1021\u1005\u102c\u1038 Residual Current Circuit Breaker<\/h2>\n<h2>\u1001\u103c\u102f\u1036\u1004\u102f\u1036\u101e\u102f\u1036\u1038\u101e\u1015\u103a\u1001\u103b\u1000\u103a<\/h2>\n<p>VIOX VRC3-63 \u101e\u100a\u103a \u1019\u103c\u1031\u1015\u103c\u1004\u103a\u1001\u103b\u102d\u102f\u1037\u101a\u103d\u1004\u103a\u1038\u1019\u103e\u102f\u1019\u103b\u102c\u1038\u1014\u103e\u1004\u1037\u103a \u101a\u102d\u102f\u1005\u102d\u1019\u1037\u103a\u1019\u103e\u102f\u1019\u103b\u102c\u1038\u1019\u103e \u1021\u1000\u1031\u102c\u1004\u103a\u1038\u1006\u102f\u1036\u1038\u1000\u102c\u1000\u103d\u101a\u103a\u1015\u1031\u1038\u101b\u1014\u103a\u1021\u1010\u103d\u1000\u103a \u1012\u102e\u1007\u102d\u102f\u1004\u103a\u1038\u1011\u102f\u1010\u103a\u1011\u102c\u1038\u101e\u1031\u102c \u1018\u1000\u103a\u1005\u102f\u1036\u101e\u102f\u1036\u1038 Residual Current Circuit Breaker (RCCB) \u1016\u103c\u1005\u103a\u1015\u102b\u101e\u100a\u103a\u104b electronic \u1014\u103e\u1004\u1037\u103a electro-magnetic \u1021\u1019\u103b\u102d\u102f\u1038\u1021\u1005\u102c\u1038\u1014\u103e\u1005\u103a\u1019\u103b\u102d\u102f\u1038\u101c\u102f\u1036\u1038\u1010\u103d\u1004\u103a \u101b\u101b\u103e\u102d\u1014\u102d\u102f\u1004\u103a\u101e\u1031\u102c \u1024 RCCB \u101e\u100a\u103a \u101a\u102f\u1036\u1000\u103c\u100a\u103a\u1005\u102d\u1010\u103a\u1001\u103b\u101b\u101e\u1031\u102c \u1005\u103d\u1019\u103a\u1038\u1006\u1031\u102c\u1004\u103a\u101b\u100a\u103a\u1014\u103e\u1004\u1037\u103a \u101c\u103b\u103e\u1015\u103a\u1005\u1005\u103a\u1010\u1015\u103a\u1006\u1004\u103a\u1019\u103e\u102f\u1021\u1019\u103b\u102d\u102f\u1038\u1019\u103b\u102d\u102f\u1038\u1021\u1010\u103d\u1000\u103a \u1019\u103c\u103e\u1004\u1037\u103a\u1010\u1004\u103a\u1011\u102c\u1038\u101e\u1031\u102c \u1018\u1031\u1038\u1000\u1004\u103a\u1038\u101b\u1031\u1038\u1021\u1004\u103a\u1039\u1002\u102b\u101b\u1015\u103a\u1019\u103b\u102c\u1038\u1000\u102d\u102f \u1015\u1031\u1038\u1015\u102b\u101e\u100a\u103a\u104b.<\/p>\n<h2>\u1021\u1013\u102d\u1000\u1021\u1004\u103a\u1039\u1002\u102b\u101b\u1015\u103a\u1019\u103b\u102c\u1038<\/h2>\n<ul>\n<li>isolation function \u1015\u102b\u101b\u103e\u102d\u101e\u1031\u102c \u1019\u103c\u1031\u1015\u103c\u1004\u103a\u1001\u103b\u102d\u102f\u1037\u101a\u103d\u1004\u103a\u1038\u1019\u103e\u102f\/\u101a\u102d\u102f\u1005\u102d\u1019\u1037\u103a\u1019\u103e\u102f\u1019\u103e \u1000\u102c\u1000\u103d\u101a\u103a\u1001\u103c\u1004\u103a\u1038<\/li>\n<li>High short-circuit current \u1001\u1036\u1014\u102d\u102f\u1004\u103a\u101b\u100a\u103a\u101b\u103e\u102d\u1019\u103e\u102f<\/li>\n<li>\u101b\u103e\u1004\u103a\u1038\u101c\u1004\u103a\u1038\u101e\u1031\u102c contact position \u100a\u103d\u103e\u1014\u103a\u1015\u103c\u1019\u103e\u102f<\/li>\n<li>\u1018\u1031\u1038\u1000\u1004\u103a\u1038\u101c\u102f\u1036\u1001\u103c\u102f\u1036\u1019\u103e\u102f\u1021\u1010\u103d\u1000\u103a \u101c\u1000\u103a\u1001\u103b\u1031\u102c\u1004\u103a\u1038\u1000\u102c\u1000\u103d\u101a\u103a\u1011\u102c\u1038\u101e\u1031\u102c connection terminals<\/li>\n<li>\u1015\u102f\u1036\u1019\u103e\u1014\u103a\u1019\u101f\u102f\u1010\u103a\u101e\u1031\u102c\u1021\u1015\u1030\u1015\u1031\u1038\u1001\u103c\u1004\u103a\u1038\u1014\u103e\u1004\u1037\u103a \u1015\u103c\u1004\u103a\u1038\u1011\u1014\u103a\u101e\u1031\u102c\u1021\u1000\u103b\u102d\u102f\u1038\u101e\u1000\u103a\u101b\u1031\u102c\u1000\u103a\u1019\u103e\u102f\u1019\u103b\u102c\u1038\u1019\u103e \u1001\u1036\u1014\u102d\u102f\u1004\u103a\u101b\u100a\u103a\u101b\u103e\u102d\u1005\u1031\u101b\u1014\u103a \u1019\u102e\u1038\u1001\u1036\u1014\u102d\u102f\u1004\u103a\u101b\u100a\u103a\u101b\u103e\u102d\u101e\u1031\u102c \u1015\u101c\u1010\u103a\u1005\u1010\u1005\u103a\u1021\u1005\u102d\u1010\u103a\u1021\u1015\u102d\u102f\u1004\u103a\u1038\u1019\u103b\u102c\u1038<\/li>\n<li>\u1019\u103c\u1031\u1015\u103c\u1004\u103a\u1001\u103b\u102d\u102f\u1037\u101a\u103d\u1004\u103a\u1038\u1019\u103e\u102f\/\u101a\u102d\u102f\u1005\u102d\u1019\u1037\u103a\u1019\u103e\u102f\u101e\u100a\u103a \u1021\u1006\u1004\u1037\u103a\u101e\u1010\u103a\u1019\u103e\u1010\u103a\u1011\u102c\u1038\u101e\u1031\u102c sensitivity \u1011\u1000\u103a\u1000\u103b\u1031\u102c\u103a\u101c\u103d\u1014\u103a\u1015\u102b\u1000 \u1021\u101c\u102d\u102f\u1021\u101c\u103b\u1031\u102c\u1000\u103a circuit disconnection<\/li>\n<li>\u1015\u102b\u101d\u102b\u1011\u1031\u102c\u1000\u103a\u1015\u1036\u1037\u1019\u103e\u102f\u1014\u103e\u1004\u1037\u103a \u101c\u102d\u102f\u1004\u103a\u1038\u1017\u102d\u102f\u1037\u1021\u102c\u1038\u1019\u103e \u101e\u102e\u1038\u1001\u103c\u102c\u1038\u101c\u100a\u103a\u1015\u1010\u103a\u1001\u103c\u1004\u103a\u1038<\/li>\n<li>\u1015\u103c\u1004\u103a\u1015\u101d\u1004\u103a\u101b\u1031\u102c\u1000\u103a\u1005\u103d\u1000\u103a\u1016\u1000\u103a\u1019\u103e\u102f\u1014\u103e\u1004\u1037\u103a \u1017\u102d\u102f\u1037\u1021\u102c\u1038\u1021\u1010\u1000\u103a\u1021\u1000\u103b\u1019\u103b\u102c\u1038\u1000\u102d\u102f \u1001\u1036\u1014\u102d\u102f\u1004\u103a\u101b\u100a\u103a\u101b\u103e\u102d\u1001\u103c\u1004\u103a\u1038<\/li>\n<\/ul>\n<h2>\u1014\u100a\u103a\u1038\u1015\u100a\u102c\u1006\u102d\u102f\u1004\u103a\u101b\u102c\u101e\u1010\u103a\u1019\u103e\u1010\u103a\u1001\u103b\u1000\u103a\u1019\u103b\u102c\u1038<\/h2>\n<ul>\n<li>\u1005\u1036\u1014\u103e\u102f\u1014\u103a\u1038: IEC61008<\/li>\n<li>\u1019\u102f\u1012\u103a- \u101c\u103b\u103e\u1015\u103a\u1005\u1005\u103a\u101e\u1036\u101c\u102d\u102f\u1000\u103a\u1021\u1019\u103b\u102d\u102f\u1038\u1021\u1005\u102c\u1038\u104a \u101c\u103b\u103e\u1015\u103a\u1005\u1005\u103a\u1021\u1019\u103b\u102d\u102f\u1038\u1021\u1005\u102c\u1038<\/li>\n<li>Residual current \u101c\u1000\u1039\u1001\u100f\u102c\u1019\u103b\u102c\u1038: A, AC<\/li>\n<li>Pole configuration: 2P (4P \u101c\u100a\u103a\u1038\u101b\u1014\u102d\u102f\u1004\u103a\u101e\u100a\u103a)<\/li>\n<li>Rated making and breaking capacity: 500A (In=25A, 40A) \u101e\u102d\u102f\u1037\u1019\u101f\u102f\u1010\u103a 10InA (In=63A, 80A, 100A, 125A)<\/li>\n<li>Rated current: 25A (40A, 63A \u101c\u100a\u103a\u1038\u101b\u1014\u102d\u102f\u1004\u103a\u101e\u100a\u103a)<\/li>\n<li>Rated voltage: AC 230(240)\/400(415)V<\/li>\n<li>\u1021\u1006\u1004\u1037\u103a\u101e\u1010\u103a\u1019\u103e\u1010\u103a\u1011\u102c\u1038\u101e\u1031\u102c \u1000\u103c\u102d\u1019\u103a\u1014\u103e\u102f\u1014\u103a\u1038- 50\/60Hz<\/li>\n<li>Rated residual operating current (I\u25b3n): 0.03A, 0.1A, 0.3A, 0.5A<\/li>\n<li>Rated residual non-operating current: 0.5I\u25b3n<\/li>\n<li>Rated conditional short-circuit current (Inc): 10kA<\/li>\n<li>Rated conditional residual short-circuit current (I\u25b3c): 10kA<\/li>\n<li>Tripping duration: instantaneous tripping \u22640.3s (0.1s)<\/li>\n<li>Residual tripping current range: 0.5I\u25b3n~I\u25b3n<\/li>\n<li>\u101c\u103b\u103e\u1015\u103a\u1005\u1005\u103a\u1005\u1000\u103a\u1015\u102d\u102f\u1004\u103a\u1038\u1006\u102d\u102f\u1004\u103a\u101b\u102c\u1001\u1036\u1014\u102d\u102f\u1004\u103a\u101b\u100a\u103a- 4000 \u101e\u1036\u101e\u101b\u102c<\/li>\n<li>Connection capacity: Rigid conductor 25mm\u00b2<\/li>\n<li>Terminal connection \u1021\u1019\u103c\u1004\u1037\u103a: 21mm<\/li>\n<li>Connection terminal: Pillar terminal with clamp<\/li>\n<li>Fastening torque: 2.0Nm<\/li>\n<li>Installation: On symmetrical DIN rail 35.5mm \u101e\u102d\u102f\u1037\u1019\u101f\u102f\u1010\u103a panel mounting<\/li>\n<li>Protection class: IP20<\/li>\n<\/ul>\n<h2>\u1000\u103b\u1014\u103a\u101b\u103e\u102d\u101e\u1031\u102c \u101c\u1000\u103a\u101b\u103e\u102d \u101c\u102f\u1015\u103a\u1006\u1031\u102c\u1004\u103a\u1001\u103b\u1000\u103a \u1016\u103c\u1010\u103a\u1010\u1031\u102c\u1000\u103a\u1001\u103b\u102d\u1014\u103a<\/h2>\n<table border=\"1\" cellpadding=\"5\">\n<tbody>\n<tr>\n<th>\u1021\u1019\u103b\u102d\u102f\u1038\u1021\u1005\u102c\u1038<\/th>\n<th>In (A)<\/th>\n<th>I\u25b3n (A)<\/th>\n<th colspan=\"4\">Residual Current (I\u25b3) \u101e\u1000\u103a\u1006\u102d\u102f\u1004\u103a\u101b\u102c Breaking Time (s)<\/th>\n<th>\u1019\u103e\u1010\u103a\u1001\u103b\u1000\u103a<\/th>\n<\/tr>\n<tr>\n<th><\/th>\n<th><\/th>\n<th><\/th>\n<th>\u1004\u102b\u25b3n<\/th>\n<th>2 I\u25b3n<\/th>\n<th>5 I\u25b3n<\/th>\n<th>5A\u104a10A\u104a20A\u104a50A\u104a100A\u104a200A\u104a500A<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<td>General type<\/td>\n<td>\u1019\u100a\u103a\u101e\u100a\u1037\u103a\u1010\u1014\u103a\u1016\u102d\u102f\u1038\u1019\u1006\u102d\u102f<\/td>\n<td>\u1019\u100a\u103a\u101e\u100a\u1037\u103a\u1010\u1014\u103a\u1016\u102d\u102f\u1038\u1019\u1006\u102d\u102f<\/td>\n<td>0.3<\/td>\n<td>0.15<\/td>\n<td>0.04<\/td>\n<td>0.04<\/td>\n<td>Max Break-\u1021\u1001\u103b\u102d\u1014\u103a<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">S Type<\/td>\n<td rowspan=\"2\">\u226525<\/td>\n<td rowspan=\"2\">&gt;0.03<\/td>\n<td>0.5<\/td>\n<td>0.2<\/td>\n<td>0.15<\/td>\n<td>0.15<\/td>\n<td>Max Break-\u1021\u1001\u103b\u102d\u1014\u103a<\/td>\n<\/tr>\n<tr>\n<td>0.13<\/td>\n<td>0.06<\/td>\n<td>0.05<\/td>\n<td>0.04<\/td>\n<td>Min non-driving time<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u1019\u103e\u1010\u103a\u1001\u103b\u1000\u103a: current I\u0394n \u101e\u100a\u103a 0.03mA \u101e\u102d\u102f\u1037\u1019\u101f\u102f\u1010\u103a \u1011\u102d\u102f\u1011\u1000\u103a\u1014\u100a\u103a\u1038\u101e\u1031\u102c general type RCBO \u101e\u100a\u103a 5I\u0394n \u1021\u1005\u102c\u1038 0.25A \u1000\u102d\u102f\u101e\u102f\u1036\u1038\u1014\u102d\u102f\u1004\u103a\u101e\u100a\u103a\u104b.<\/p>\n<h2>\u1021\u101e\u102f\u1036\u1038\u1001\u103b\u1019\u103e\u102f<\/h2>\n<ul>\n<li>\u101c\u1030\u1014\u1031\u1021\u102d\u1019\u103a\u101c\u103b\u103e\u1015\u103a\u1005\u1005\u103a\u1005\u1014\u1005\u103a\u1019\u103b\u102c\u1038<\/li>\n<li>\u101c\u102f\u1015\u103a\u1004\u1014\u103a\u1038\u101e\u102f\u1036\u1038 \u1021\u1006\u1031\u102c\u1000\u103a\u1021\u1021\u102f\u1036\u1019\u103b\u102c\u1038<\/li>\n<li>\u1005\u1000\u103a\u1019\u103e\u102f\u1010\u1015\u103a\u1006\u1004\u103a\u1019\u103e\u102f\u1019\u103b\u102c\u1038<\/li>\n<li>\u1016\u103c\u1014\u1037\u103a\u101d\u1031\u101b\u1031\u1038\u1018\u102f\u1010\u103a\u1019\u103b\u102c\u1038<\/li>\n<li>\u101c\u103b\u103e\u1015\u103a\u1005\u1005\u103a\u1006\u102c\u1038\u1000\u1005\u103a\u1021\u1019\u103b\u102d\u102f\u1038\u1019\u103b\u102d\u102f\u1038\u1010\u103d\u1004\u103a \u1019\u103c\u1031\u1015\u103c\u1004\u103a\u101a\u102d\u102f\u1005\u102d\u1019\u1037\u103a\u1019\u103e\u102f\u1000\u102c\u1000\u103d\u101a\u103a\u1001\u103c\u1004\u103a\u1038<\/li>\n<\/ul>\n<h2>\u1021\u102c\u1038\u101e\u102c\u1001\u103b\u1000\u103a\u1019\u103b\u102c\u1038<\/h2>\n<ul>\n<li>Dual protection: \u1019\u103c\u1031\u1015\u103c\u1004\u103a\u1001\u103b\u102d\u102f\u1037\u101a\u103d\u1004\u103a\u1038\u1019\u103e\u102f\u1014\u103e\u1004\u1037\u103a \u101a\u102d\u102f\u1005\u102d\u1019\u1037\u103a\u1019\u103e\u102f<\/li>\n<li>\u1019\u103c\u103e\u1004\u1037\u103a\u1010\u1004\u103a\u1011\u102c\u1038\u101e\u1031\u102c \u101a\u102f\u1036\u1000\u103c\u100a\u103a\u1005\u102d\u1010\u103a\u1001\u103b\u101b\u1019\u103e\u102f\u1021\u1010\u103d\u1000\u103a High short-circuit current tolerance<\/li>\n<li>DIN rail \u101e\u102d\u102f\u1037\u1019\u101f\u102f\u1010\u103a panel mounting \u101b\u103d\u1031\u1038\u1001\u103b\u101a\u103a\u1019\u103e\u102f\u1019\u103b\u102c\u1038\u1016\u103c\u1004\u1037\u103a \u101c\u103d\u101a\u103a\u1000\u1030\u1005\u103d\u102c\u1010\u1015\u103a\u1006\u1004\u103a\u1014\u102d\u102f\u1004\u103a\u1001\u103c\u1004\u103a\u1038<\/li>\n<li>\u101c\u103b\u1004\u103a\u1019\u103c\u1014\u103a\u1005\u103d\u102c \u1001\u103b\u102d\u102f\u1037\u101a\u103d\u1004\u103a\u1038\u1001\u103b\u1000\u103a\u1000\u102d\u102f \u1016\u1031\u102c\u103a\u1011\u102f\u1010\u103a\u1014\u102d\u102f\u1004\u103a\u101b\u1014\u103a \u101b\u103e\u1004\u103a\u1038\u101c\u1004\u103a\u1038\u101e\u1031\u102c \u1021\u1001\u103c\u1031\u1021\u1014\u1031\u100a\u103d\u103e\u1014\u103a\u1015\u103c\u1019\u103e\u102f<\/li>\n<li>\u1019\u102e\u1038\u1001\u1036\u1014\u102d\u102f\u1004\u103a\u101b\u100a\u103a\u101b\u103e\u102d\u101e\u1031\u102c\u1015\u1005\u1039\u1005\u100a\u103a\u1038\u1019\u103b\u102c\u1038\u1016\u103c\u1004\u1037\u103a \u1010\u102c\u101b\u103e\u100a\u103a\u1001\u1036\u101e\u1031\u102c \u1010\u100a\u103a\u1006\u1031\u102c\u1000\u103a\u1019\u103e\u102f<\/li>\n<li>\u1021\u101b\u100a\u103a\u1021\u101e\u103d\u1031\u1038\u1021\u102c\u1019\u1001\u1036\u1001\u103b\u1000\u103a\u1021\u1010\u103d\u1000\u103a \u1014\u102d\u102f\u1004\u103a\u1004\u1036\u1010\u1000\u102c\u1005\u1036\u1014\u103e\u102f\u1014\u103a\u1038\u1019\u103b\u102c\u1038\u1014\u103e\u1004\u1037\u103a \u1000\u102d\u102f\u1000\u103a\u100a\u102e\u1015\u102b\u101e\u100a\u103a\u104b<\/li>\n<\/ul>\n<h2>\u1018\u1031\u1038\u1000\u1004\u103a\u1038\u101b\u1031\u1038\u1021\u1004\u103a\u1039\u1002\u102b\u101b\u1015\u103a\u1019\u103b\u102c\u1038<\/h2>\n<ul>\n<li>\u1019\u103c\u1031\u1015\u103c\u1004\u103a\u1001\u103b\u102d\u102f\u1037\u101a\u103d\u1004\u103a\u1038\u1019\u103e\u102f\u1000\u102c\u1000\u103d\u101a\u103a\u1001\u103c\u1004\u103a\u1038<\/li>\n<li>\u101a\u102d\u102f\u1005\u102d\u1019\u1037\u103a\u1019\u103e\u102f\u1000\u102c\u1000\u103d\u101a\u103a\u1001\u103c\u1004\u103a\u1038<\/li>\n<li>Isolation function<\/li>\n<li>\u101c\u1000\u103a\u1001\u103b\u1031\u102c\u1004\u103a\u1038\u1000\u102c\u1000\u103d\u101a\u103a\u1011\u102c\u1038\u101e\u1031\u102c connection terminals<\/li>\n<li>\u1021\u1006\u1004\u1037\u103a\u101e\u1010\u103a\u1019\u103e\u1010\u103a\u1011\u102c\u1038\u101e\u1031\u102c sensitivity \u1011\u1000\u103a\u1000\u103b\u1031\u102c\u103a\u101c\u103d\u1014\u103a\u101e\u1031\u102c \u1001\u103b\u102d\u102f\u1037\u101a\u103d\u1004\u103a\u1038\u1001\u103b\u1000\u103a\u1019\u103b\u102c\u1038\u1021\u1010\u103d\u1000\u103a \u1021\u101c\u102d\u102f\u1021\u101c\u103b\u1031\u102c\u1000\u103a circuit disconnection<\/li>\n<\/ul>\n<h2>\u1021\u1010\u102d\u102f\u1004\u103a\u1038\u1021\u1010\u102c<\/h2>\n<p><a href=\"https:\/\/test.viox.com\/my\/?attachment_id=5594\" rel=\"attachment wp-att-5594\"><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-5594\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VRC3-63-2P-25A-RCCB01.webp\" alt=\"\" width=\"1466\" height=\"478\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VRC3-63-2P-25A-RCCB01.webp 1466w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VRC3-63-2P-25A-RCCB01-300x98.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VRC3-63-2P-25A-RCCB01-1024x334.webp 1024w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VRC3-63-2P-25A-RCCB01-768x250.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VRC3-63-2P-25A-RCCB01-600x196.webp 600w\" sizes=\"(max-width: 1466px) 100vw, 1466px\" \/><\/a><\/p>\n<h2>\u1021\u101b\u100a\u103a\u1021\u101e\u103d\u1031\u1038\u1000\u1031\u102c\u1004\u103a\u1038\u1001\u103c\u1004\u103a\u1038\u1021\u102c\u1019\u1001\u1036\u1001\u103b\u1000\u103a<\/h2>\n<p>VIOX \u101e\u100a\u103a \u1014\u102d\u102f\u1004\u103a\u1004\u1036\u1010\u1000\u102c\u1005\u1036\u1014\u103e\u102f\u1014\u103a\u1038\u1019\u103b\u102c\u1038\u1014\u103e\u1004\u1037\u103a\u1000\u102d\u102f\u1000\u103a\u100a\u102e\u101e\u1031\u102c \u1021\u101b\u100a\u103a\u1021\u101e\u103d\u1031\u1038\u1019\u103c\u1004\u1037\u103a RCCB \u1019\u103b\u102c\u1038\u1000\u102d\u102f \u1015\u1036\u1037\u1015\u102d\u102f\u1038\u1015\u1031\u1038\u101b\u1014\u103a \u1000\u1010\u102d\u1015\u103c\u102f\u1015\u102b\u101e\u100a\u103a\u104b \u1000\u103b\u103d\u1014\u103a\u102f\u1015\u103a\u1010\u102d\u102f\u1037\u104f\u1011\u102f\u1010\u103a\u1000\u102f\u1014\u103a\u1019\u103b\u102c\u1038\u101e\u100a\u103a \u101c\u103b\u103e\u1015\u103a\u1005\u1005\u103a\u1010\u1015\u103a\u1006\u1004\u103a\u1019\u103e\u102f\u1021\u1019\u103b\u102d\u102f\u1038\u1019\u103b\u102d\u102f\u1038\u1010\u103d\u1004\u103a \u101a\u102f\u1036\u1000\u103c\u100a\u103a\u1005\u102d\u1010\u103a\u1001\u103b\u101b\u1019\u103e\u102f\u104a \u1018\u1031\u1038\u1000\u1004\u103a\u1038\u1019\u103e\u102f\u1014\u103e\u1004\u1037\u103a \u101b\u1031\u101b\u103e\u100a\u103a\u1005\u103d\u1019\u103a\u1038\u1006\u1031\u102c\u1004\u103a\u101b\u100a\u103a\u1000\u102d\u102f\u101e\u1031\u1001\u103b\u102c\u1005\u1031\u101b\u1014\u103a \u1010\u1004\u103a\u1038\u1000\u103b\u1015\u103a\u101e\u1031\u102c\u1005\u1019\u103a\u1038\u101e\u1015\u103a\u1019\u103e\u102f\u1019\u103b\u102c\u1038\u1000\u102d\u102f \u1001\u1036\u101a\u1030\u1015\u102b\u101e\u100a\u103a\u104b.<\/p>\n<h2><\/h2>\n<\/div>","protected":false},"excerpt":{"rendered":"<div class=\"msg-content MuiBox-root css-0\">\n<div class=\"break-words\">\n<p>VIOX VRC3-63 RCCB \u101e\u100a\u103a 25A \u1021\u1011\u102d \u1005\u1014\u1005\u103a\u1019\u103b\u102c\u1038\u1021\u1010\u103d\u1000\u103a \u1019\u103c\u1031\u1015\u103c\u1004\u103a\u1001\u103b\u102d\u102f\u1037\u101a\u103d\u1004\u103a\u1038\u1019\u103e\u102f\u1019\u103b\u102c\u1038\u1014\u103e\u1004\u1037\u103a \u101a\u102d\u102f\u1005\u102d\u1019\u1037\u103a\u1019\u103e\u102f\u1019\u103b\u102c\u1038\u1019\u103e \u1021\u1000\u1031\u102c\u1004\u103a\u1038\u1006\u102f\u1036\u1038\u1000\u102c\u1000\u103d\u101a\u103a\u1015\u1031\u1038\u1015\u102b\u101e\u100a\u103a\u104b \u1024 IEC61008 \u1014\u103e\u1004\u1037\u103a\u1000\u102d\u102f\u1000\u103a\u100a\u102e\u101e\u1031\u102c\u1000\u102d\u101b\u102d\u101a\u102c\u1010\u103d\u1004\u103a 10kA \u1021\u1006\u1004\u1037\u103a\u101e\u1010\u103a\u1019\u103e\u1010\u103a\u1011\u102c\u1038\u101e\u1031\u102c conditional short-circuit current \u1015\u102b\u101b\u103e\u102d\u1015\u103c\u102e\u1038 0.03A, 0.1A, 0.3A \u1014\u103e\u1004\u1037\u103a 0.5A \u1010\u102d\u102f\u1037\u104f residual operating currents \u1019\u103b\u102c\u1038\u1000\u102d\u102f \u1021\u1011\u1031\u102c\u1000\u103a\u1021\u1015\u1036\u1037\u1015\u1031\u1038\u1015\u102b\u101e\u100a\u103a\u104b 2P configuration \u1016\u103c\u1004\u1037\u103a\u101b\u101b\u103e\u102d\u1014\u102d\u102f\u1004\u103a\u1015\u103c\u102e\u1038 230\/400V AC, 50\/60Hz \u1010\u103d\u1004\u103a\u101c\u100a\u103a\u1015\u1010\u103a\u1015\u102b\u101e\u100a\u103a\u104b \u1021\u1013\u102d\u1000\u1021\u102c\u1038\u101e\u102c\u1001\u103b\u1000\u103a\u1019\u103b\u102c\u1038\u1010\u103d\u1004\u103a electronic \u1014\u103e\u1004\u1037\u103a electro-magnetic \u1021\u1019\u103b\u102d\u102f\u1038\u1021\u1005\u102c\u1038\u1019\u103b\u102c\u1038\u104a IP20 protection \u1014\u103e\u1004\u1037\u103a 4,000-cycle electro-mechanical endurance \u1010\u102d\u102f\u1037\u1015\u102b\u101d\u1004\u103a\u1015\u102b\u101e\u100a\u103a\u104b \u104e\u1004\u103a\u1038\u104f \u101b\u103e\u1004\u103a\u1038\u101c\u1004\u103a\u1038\u101e\u1031\u102c\u1021\u1014\u1031\u1021\u1011\u102c\u1038\u100a\u103d\u103e\u1014\u103a\u1015\u103c\u1019\u103e\u102f\u104a \u101c\u1000\u103a\u1001\u103b\u1031\u102c\u1004\u103a\u1038\u1000\u102c\u1000\u103d\u101a\u103a\u1011\u102c\u1038\u101e\u1031\u102c terminals \u1014\u103e\u1004\u1037\u103a \u1019\u102e\u1038\u1001\u1036\u1014\u102d\u102f\u1004\u103a\u101b\u100a\u103a\u101b\u103e\u102d\u101e\u1031\u102c \u1010\u100a\u103a\u1006\u1031\u102c\u1000\u103a\u1019\u103e\u102f\u1010\u102d\u102f\u1037\u1000\u103c\u1031\u102c\u1004\u1037\u103a \u1024 RCCB \u101e\u100a\u103a \u101c\u103d\u101a\u103a\u1000\u1030\u1005\u103d\u102c\u101c\u100a\u103a\u1015\u1010\u103a\u1014\u102d\u102f\u1004\u103a\u1015\u103c\u102e\u1038 \u1018\u1031\u1038\u1000\u1004\u103a\u1038\u1019\u103e\u102f\u1000\u102d\u102f \u1019\u103c\u103e\u1004\u1037\u103a\u1010\u1004\u103a\u1015\u1031\u1038\u1015\u102b\u101e\u100a\u103a\u104b \u101c\u1030\u1014\u1031\u1021\u102d\u1019\u103a\u104a \u1005\u102e\u1038\u1015\u103d\u102c\u1038\u101b\u1031\u1038\u1014\u103e\u1004\u1037\u103a \u1005\u1000\u103a\u1019\u103e\u102f\u101c\u102f\u1015\u103a\u1004\u1014\u103a\u1038\u101e\u102f\u1036\u1038\u1019\u103b\u102c\u1038\u1021\u1010\u103d\u1000\u103a \u101e\u1004\u1037\u103a\u101c\u103b\u1031\u102c\u103a\u1015\u103c\u102e\u1038 \u1021\u101c\u102d\u102f\u1021\u101c\u103b\u1031\u102c\u1000\u103a circuit disconnection \u1014\u103e\u1004\u1037\u103a high short-circuit tolerance \u1000\u102d\u102f\u1015\u1031\u1038\u1015\u102b\u101e\u100a\u103a\u104b \u1000\u102d\u101b\u102d\u101a\u102c\u104f 25mm\u00b2 terminal capacity, 2.0Nm fastening torque \u1014\u103e\u1004\u1037\u103a 35.5mm DIN rail mounting \u1010\u102d\u102f\u1037\u101e\u100a\u103a \u1016\u103c\u1014\u1037\u103a\u1016\u103c\u1030\u1038\u101b\u1031\u1038\u1018\u102f\u1010\u103a\u1019\u103b\u102c\u1038\u1014\u103e\u1004\u1037\u103a \u101c\u103b\u103e\u1015\u103a\u1005\u1005\u103a\u1006\u102c\u1038\u1000\u1005\u103a\u1019\u103b\u102c\u1038\u1010\u103d\u1004\u103a \u1019\u103c\u1031\u1015\u103c\u1004\u103a\u101a\u102d\u102f\u1005\u102d\u1019\u1037\u103a\u1019\u103e\u102f\u1000\u102c\u1000\u103d\u101a\u103a\u101b\u1031\u1038\u101c\u102d\u102f\u1021\u1015\u103a\u1001\u103b\u1000\u103a\u1021\u1019\u103b\u102d\u102f\u1038\u1019\u103b\u102d\u102f\u1038\u1021\u1010\u103d\u1000\u103a \u1021\u1000\u1031\u102c\u1004\u103a\u1038\u1006\u102f\u1036\u1038\u1016\u103c\u1005\u103a\u1005\u1031\u1015\u102b\u101e\u100a\u103a\u104b.<\/p>\n<\/div>\n<\/div>","protected":false},"featured_media":5595,"comment_status":"closed","ping_status":"closed","template":"","meta":{"inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[],"product_cat":[116,131],"product_tag":[],"class_list":{"0":"post-5593","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-low-voltage-protection-devices","7":"product_cat-rccb","8":"desktop-align-left","9":"tablet-align-left","10":"mobile-align-left","12":"first","13":"instock","14":"shipping-taxable","15":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/test.viox.com\/my\/wp-json\/wp\/v2\/product\/5593","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/test.viox.com\/my\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/test.viox.com\/my\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/test.viox.com\/my\/wp-json\/wp\/v2\/comments?post=5593"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/test.viox.com\/my\/wp-json\/wp\/v2\/media\/5595"}],"wp:attachment":[{"href":"https:\/\/test.viox.com\/my\/wp-json\/wp\/v2\/media?parent=5593"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/test.viox.com\/my\/wp-json\/wp\/v2\/product_brand?post=5593"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/test.viox.com\/my\/wp-json\/wp\/v2\/product_cat?post=5593"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/test.viox.com\/my\/wp-json\/wp\/v2\/product_tag?post=5593"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}