{"id":5565,"date":"2024-09-13T15:05:36","date_gmt":"2024-09-13T07:05:36","guid":{"rendered":"https:\/\/viox.com\/?post_type=product&#038;p=5565"},"modified":"2024-09-13T15:08:23","modified_gmt":"2024-09-13T07:08:23","slug":"viox-vm2-125-1-4p-mcb","status":"publish","type":"product","link":"https:\/\/test.viox.com\/my\/product\/viox-vm2-125-1-4p-mcb\/","title":{"rendered":"VIOX VM2-125 1-4P MCB"},"content":{"rendered":"<div class=\"product-intro\">\n<h2>VIOX VM2-125 1-4P Miniature Circuit Breaker (MCB)<\/h2>\n<h2>\u1001\u103c\u102f\u1036\u1004\u102f\u1036\u101e\u102f\u1036\u1038\u101e\u1015\u103a\u1001\u103b\u1000\u103a<\/h2>\n<p>VIOX VM2-125 Miniature Circuit Breaker (MCB) \u1000\u102d\u102f rated voltage 230V\/400V \u1014\u103e\u1004\u1037\u103a rated current 20A \u1019\u103e 125A \u1021\u1011\u102d\u101b\u103e\u102d\u101e\u1031\u102c AC 50Hz\/60Hz \u1005\u1014\u1005\u103a\u1019\u103b\u102c\u1038\u1010\u103d\u1004\u103a overload \u1014\u103e\u1004\u1037\u103a short circuits \u1019\u103b\u102c\u1038\u1019\u103e\u1000\u102c\u1000\u103d\u101a\u103a\u101b\u1014\u103a\u1021\u1010\u103d\u1000\u103a\u1012\u102e\u1007\u102d\u102f\u1004\u103a\u1038\u1011\u102f\u1010\u103a\u1011\u102c\u1038\u1015\u102b\u101e\u100a\u103a\u104b \u1015\u102f\u1036\u1019\u103e\u1014\u103a\u1021\u1001\u103c\u1031\u1021\u1014\u1031\u1019\u103b\u102c\u1038\u1010\u103d\u1004\u103a\u1019\u1000\u103c\u102c\u1001\u100f on-and-off switch \u101c\u102f\u1015\u103a\u1006\u1031\u102c\u1004\u103a\u1019\u103e\u102f\u1019\u103b\u102c\u1038\u1021\u1010\u103d\u1000\u103a\u101e\u1004\u1037\u103a\u1010\u1031\u102c\u103a\u1015\u103c\u102e\u1038\u1005\u1000\u103a\u1019\u103e\u102f\u104a \u1000\u1030\u1038\u101e\u1014\u103a\u1038\u101b\u1031\u102c\u1004\u103a\u1038\u101d\u101a\u103a\u101b\u1031\u1038\u104a \u1021\u1011\u1015\u103a\u1019\u103c\u1004\u1037\u103a\u1021\u1006\u1031\u102c\u1000\u103a\u1021\u1021\u102f\u1036\u1019\u103b\u102c\u1038\u1014\u103e\u1004\u1037\u103a\u1021\u102d\u1019\u103a\u101e\u102f\u1036\u1038 application \u1019\u103b\u102c\u1038\u1010\u103d\u1004\u103a\u1000\u103b\u101a\u103a\u1015\u103c\u1014\u1037\u103a\u1005\u103d\u102c\u1021\u101e\u102f\u1036\u1038\u1015\u103c\u102f\u101e\u100a\u103a\u104b.<\/p>\n<h2>\u1021\u1013\u102d\u1000\u1021\u1004\u103a\u1039\u1002\u102b\u101b\u1015\u103a\u1019\u103b\u102c\u1038<\/h2>\n<ul>\n<li>10kA \u104f\u1019\u103c\u1004\u1037\u103a\u1019\u102c\u1038\u101e\u1031\u102c short-circuit capacity<\/li>\n<li>125A \u1021\u1011\u102d current \u101e\u101a\u103a\u1006\u1031\u102c\u1004\u103a\u101e\u1031\u102c circuits \u1019\u103b\u102c\u1038\u1000\u102d\u102f\u1000\u102c\u1000\u103d\u101a\u103a\u1015\u1031\u1038\u101e\u100a\u103a<\/li>\n<li>\u1006\u1000\u103a\u101e\u103d\u101a\u103a\u101b\u1014\u103a\u1021\u1014\u1031\u1021\u1011\u102c\u1038\u100a\u103d\u103e\u1014\u103a\u1015\u103c<\/li>\n<li>\u1021\u102d\u1019\u103a\u101e\u102f\u1036\u1038\u1014\u103e\u1004\u1037\u103a\u1021\u101c\u102c\u1038\u1010\u1030\u1010\u1015\u103a\u1006\u1004\u103a\u1019\u103e\u102f\u1019\u103b\u102c\u1038\u1010\u103d\u1004\u103a main switch \u1021\u1016\u103c\u1005\u103a\u101e\u1004\u1037\u103a\u101c\u103b\u1031\u102c\u103a\u101e\u100a\u103a\u104b<\/li>\n<li>\u1021\u101c\u103d\u1014\u103a\u1000\u1031\u102c\u1004\u103a\u1038\u1019\u103d\u1014\u103a\u101e\u1031\u102c\u1005\u103b\u1031\u1038\u1014\u103e\u102f\u1014\u103a\u1038\u1014\u103e\u1004\u1037\u103a\u1021\u101b\u100a\u103a\u1021\u101e\u103d\u1031\u1038\u1021\u1001\u103b\u102d\u102f\u1038<\/li>\n<\/ul>\n<h2>\u1014\u100a\u103a\u1038\u1015\u100a\u102c\u1006\u102d\u102f\u1004\u103a\u101b\u102c\u101e\u1010\u103a\u1019\u103e\u1010\u103a\u1001\u103b\u1000\u103a\u1019\u103b\u102c\u1038<\/h2>\n<ul>\n<li>\u1005\u1036\u101e\u1010\u103a\u1019\u103e\u1010\u103a\u1001\u103b\u1000\u103a- IEC\/EN 60898-1<\/li>\n<li>Pole configurations: 1P, 1P+N, 2P, 3P, 3P+N, 4P<\/li>\n<li>Rated voltage: AC 230V\/400V<\/li>\n<li>Rated current: 20A, 25A, 32A, 40A, 50A, 63A, 80A, 100A, 125A<\/li>\n<li>Tripping curve: C, D<\/li>\n<li>Rated short-circuit capacity (Icn): 10000A<\/li>\n<li>Rated service short-circuit capacity (Ics): 7500A<\/li>\n<li>\u1021\u1006\u1004\u1037\u103a\u101e\u1010\u103a\u1019\u103e\u1010\u103a\u1011\u102c\u1038\u101e\u1031\u102c \u1000\u103c\u102d\u1019\u103a\u1014\u103e\u102f\u1014\u103a\u1038- 50\/60Hz<\/li>\n<li>Rated impulse withstand voltage (Uimp): 6kV<\/li>\n<li>Connection terminal: Pillar terminal with clamp<\/li>\n<\/ul>\n<h2>\u1005\u103d\u1019\u103a\u1038\u1006\u1031\u102c\u1004\u103a\u101b\u100a\u103a \u101c\u1000\u1039\u1001\u100f\u102c\u1019\u103b\u102c\u1038<\/h2>\n<ul>\n<li>Electro-mechanical endurance: In\u2264100A = 10000 cycles, In=125A = 8000 cycles<\/li>\n<li>Terminal connection height: 20mm<\/li>\n<li>Connection capacity: Flexible conductor 35mm\u00b2, Rigid conductor 50mm\u00b2<\/li>\n<li>Installation: On symmetrical DIN rail 35mm or panel mounting<\/li>\n<\/ul>\n<h2>Overload Current Protection \u101c\u1000\u1039\u1001\u100f\u102c\u1019\u103b\u102c\u1038<\/h2>\n<table border=\"1\" cellpadding=\"5\">\n<tbody>\n<tr>\n<th>\u1005\u1019\u103a\u1038<\/th>\n<th>\u1001\u101c\u102f\u1010\u103a\u1010\u102d\u102f\u1000\u103a\u1001\u103c\u1004\u103a\u1038 \u1021\u1019\u103b\u102d\u102f\u1038\u1021\u1005\u102c\u1038<\/th>\n<th>\u1005\u1019\u103a\u1038\u101e\u1015\u103a\u1006\u1032<\/th>\n<th>\u1000\u1014\u1026\u1038\u1021\u1001\u103c\u1031\u1021\u1014\u1031<\/th>\n<th>\u1001\u101c\u102f\u1010\u103a\u1010\u102d\u102f\u1000\u103a\u101e\u100a\u1037\u103a\u1021\u1001\u103b\u102d\u1014\u103a \u101e\u102d\u102f\u1037\u1019\u101f\u102f\u1010\u103a \u1001\u101c\u102f\u1010\u103a\u1019\u1010\u102d\u102f\u1000\u103a\u101e\u1031\u102c\u1021\u1001\u103b\u102d\u1014\u103a \u1015\u1036\u1037\u1015\u102d\u102f\u1038\u1019\u103e\u102f<\/th>\n<th>\u101b\u101c\u1012\u103a<\/th>\n<\/tr>\n<tr>\n<td>a<\/td>\n<td>\u1021\u1001\u103b\u102d\u1014\u103a\u1000\u103c\u1014\u1037\u103a\u1000\u103c\u102c\u1001\u103c\u1004\u103a\u1038\u104b<\/td>\n<td>1.05\u101c\u1000\u103a\u1019<\/td>\n<td>\u1021\u1031\u1038<\/td>\n<td>t\u22641h (In\u226463A), t\u22642h (&gt;63A \u1021\u1010\u103d\u1004\u103a\u1038)<\/td>\n<td>Tripping \u1019\u101b\u103e\u102d\u1015\u102b\u104b<\/td>\n<\/tr>\n<tr>\n<td>\u1001<\/td>\n<td>\u1021\u1001\u103b\u102d\u1014\u103a\u1000\u103c\u1014\u1037\u103a\u1000\u103c\u102c\u1001\u103c\u1004\u103a\u1038\u104b<\/td>\n<td>1.30In<\/td>\n<td>\u1005\u1019\u103a\u1038\u101e\u1015\u103a\u1015\u103c\u102e\u1038\u1014\u1031\u102c\u1000\u103a<\/td>\n<td>t&lt;1h (In\u226463A), t&lt;2h (&gt;63A \u1021\u1010\u103d\u1004\u103a\u1038)<\/td>\n<td>\u1001\u101c\u102f\u1010\u103a\u1010\u102d\u102f\u1000\u103a\u1001\u103c\u1004\u103a\u1038\u104b<\/td>\n<\/tr>\n<tr>\n<td>\u1002<\/td>\n<td>\u1021\u1001\u103b\u102d\u1014\u103a\u1000\u103c\u1014\u1037\u103a\u1000\u103c\u102c\u1001\u103c\u1004\u103a\u1038\u104b<\/td>\n<td>2In<\/td>\n<td>\u1021\u1031\u1038<\/td>\n<td>1s &lt;t&lt;60s (In\u226463A), 1s&lt;t 63A)<\/td>\n<td>\u1001\u101c\u102f\u1010\u103a\u1010\u102d\u102f\u1000\u103a\u1001\u103c\u1004\u103a\u1038\u104b<\/td>\n<\/tr>\n<tr>\n<td>\u1003<\/td>\n<td>\u1001\u103b\u1000\u103a\u1001\u103c\u1004\u103a\u1038<\/td>\n<td>8In<\/td>\n<td>\u1021\u1031\u1038<\/td>\n<td>t\u22640.2s<\/td>\n<td>Tripping \u1019\u101b\u103e\u102d\u1015\u102b\u104b<\/td>\n<\/tr>\n<tr>\n<td>\u1004<\/td>\n<td>\u1001\u103b\u1000\u103a\u1001\u103c\u1004\u103a\u1038<\/td>\n<td>12In<\/td>\n<td>\u1021\u1031\u1038<\/td>\n<td>t&lt;0.2s<\/td>\n<td>\u1001\u101c\u102f\u1010\u103a\u1010\u102d\u102f\u1000\u103a\u1001\u103c\u1004\u103a\u1038\u104b<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>\u1021\u101e\u102f\u1036\u1038\u1001\u103b\u1019\u103e\u102f<\/h2>\n<ul>\n<li>\u1005\u1000\u103a\u1019\u103e\u102f\u101c\u103b\u103e\u1015\u103a\u1005\u1005\u103a\u1005\u1014\u1005\u103a\u1019\u103b\u102c\u1038<\/li>\n<li>\u101c\u102f\u1015\u103a\u1004\u1014\u103a\u1038\u101e\u102f\u1036\u1038 \u1021\u1006\u1031\u102c\u1000\u103a\u1021\u1021\u102f\u1036\u1019\u103b\u102c\u1038<\/li>\n<li>High-rise buildings<\/li>\n<li>\u1021\u102d\u1019\u103a\u101e\u102f\u1036\u1038\u101c\u103b\u103e\u1015\u103a\u1005\u1005\u103a\u1010\u1015\u103a\u1006\u1004\u103a\u1019\u103e\u102f\u1019\u103b\u102c\u1038<\/li>\n<\/ul>\n<h2>\u1021\u101c\u102f\u1015\u103a\u1021\u1001\u103c\u1031\u1001\u1036<\/h2>\n<p>VIOX VM2-125 MCB \u101e\u100a\u103a overload protection \u1021\u1010\u103d\u1000\u103a bimetallic strip \u1014\u103e\u1004\u1037\u103a short-circuit protection \u1021\u1010\u103d\u1000\u103a electromagnetic mechanism \u1000\u102d\u102f\u1021\u101e\u102f\u1036\u1038\u1015\u103c\u102f\u104d\u101c\u100a\u103a\u1015\u1010\u103a\u101e\u100a\u103a\u104b overload \u1016\u103c\u1005\u103a\u1015\u1031\u102b\u103a\u1014\u1031\u1005\u1009\u103a bimetallic strip \u101e\u100a\u103a\u1021\u1015\u1030\u1015\u1031\u1038\u1015\u103c\u102e\u1038\u1000\u103d\u1031\u1038\u101e\u103d\u102c\u1038\u1000\u102c operating mechanism \u1014\u103e\u1004\u1037\u103a\u1001\u103b\u102d\u1010\u103a\u1006\u1000\u103a\u1011\u102c\u1038\u101e\u1031\u102c electromechanical latch \u1000\u102d\u102f\u101c\u103d\u103e\u1010\u103a\u1015\u1031\u1038\u101e\u100a\u103a\u104b \u1024\u101c\u102f\u1015\u103a\u1006\u1031\u102c\u1004\u103a\u1001\u103b\u1000\u103a\u101e\u100a\u103a MCB contacts \u1019\u103b\u102c\u1038\u1000\u102d\u102f\u1016\u103d\u1004\u1037\u103a\u1015\u103c\u102e\u1038 current \u1005\u102e\u1038\u1006\u1004\u103a\u1038\u1019\u103e\u102f\u1000\u102d\u102f\u1021\u1014\u103e\u1031\u102c\u1004\u1037\u103a\u1021\u101a\u103e\u1000\u103a\u1015\u1031\u1038\u101e\u100a\u103a\u104b short circuits \u1019\u103b\u102c\u1038\u1021\u1010\u103d\u1000\u103a electromagnetic mechanism \u101e\u100a\u103a\u1021\u101c\u103b\u1004\u103a\u1021\u1019\u103c\u1014\u103a tripping \u1000\u102d\u102f\u1015\u1031\u1038\u101e\u100a\u103a\u104b trip \u1016\u103c\u1005\u103a\u1015\u103c\u102e\u1038\u1014\u1031\u102c\u1000\u103a current \u1005\u102e\u1038\u1006\u1004\u103a\u1038\u1019\u103e\u102f\u1000\u102d\u102f\u1015\u103c\u1014\u103a\u101c\u100a\u103a\u101b\u101b\u103e\u102d\u101b\u1014\u103a manual reset \u101c\u102d\u102f\u1021\u1015\u103a\u101e\u100a\u103a\u104b.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<div class=\"msg-content MuiBox-root css-0\">\n<div class=\"break-words\">\n<p>VIOX VM2-125 MCB \u101e\u100a\u103a 125A \u1021\u1011\u102d\u101b\u103e\u102d\u101e\u1031\u102c \u101c\u103b\u103e\u1015\u103a\u1005\u1005\u103a\u1005\u1014\u1005\u103a\u1019\u103b\u102c\u1038\u1021\u1010\u103d\u1000\u103a \u1001\u102d\u102f\u1004\u103a\u1019\u102c\u101e\u1031\u102c\u1000\u102c\u1000\u103d\u101a\u103a\u1019\u103e\u102f\u1015\u1031\u1038\u1015\u102b\u101e\u100a\u103a\u104b \u1024 IEC\/EN 60898-1 \u1005\u1036\u1014\u103e\u102f\u1014\u103a\u1038\u1014\u103e\u1004\u1037\u103a\u1000\u102d\u102f\u1000\u103a\u100a\u102e\u101e\u1031\u102c\u1000\u102d\u101b\u102d\u101a\u102c\u101e\u100a\u103a 10kA short-circuit capacity \u1015\u102b\u101b\u103e\u102d\u1015\u103c\u102e\u1038 230\/400V AC \u1010\u103d\u1004\u103a 20A \u1019\u103e 125A \u1021\u1011\u102d current ratings \u1000\u102d\u102f\u1011\u1031\u102c\u1000\u103a\u1015\u1036\u1037\u1015\u1031\u1038\u101e\u100a\u103a\u104b 1P, 1P+N, 2P, 3P, 3P+N \u1014\u103e\u1004\u1037\u103a 4P configurations \u1019\u103b\u102c\u1038\u1010\u103d\u1004\u103a\u101b\u101b\u103e\u102d\u1014\u102d\u102f\u1004\u103a\u1015\u103c\u102e\u1038 \u104e\u1004\u103a\u1038\u101e\u100a\u103a C \u1014\u103e\u1004\u1037\u103a D tripping curves \u1019\u103b\u102c\u1038\u1000\u102d\u102f\u1005\u102f\u1036\u101c\u1004\u103a\u101e\u1031\u102c application \u1019\u103b\u102c\u1038\u1021\u1010\u103d\u1000\u103a\u1015\u1031\u1038\u1015\u102b\u101e\u100a\u103a\u104b \u1021\u1013\u102d\u1000\u1021\u102c\u1038\u101e\u102c\u1001\u103b\u1000\u103a\u1019\u103b\u102c\u1038\u1019\u103e\u102c 6kV impulse withstand voltage, contact position indication \u1014\u103e\u1004\u1037\u103a overload \u1014\u103e\u1004\u1037\u103a short-circuit protection \u1021\u1010\u103d\u1000\u103a dual protection mechanisms \u1010\u102d\u102f\u1037\u1015\u102b\u101d\u1004\u103a\u101e\u100a\u103a\u104b 10,000 cycle electro-mechanical endurance \u1021\u1011\u102d\u1015\u102b\u101d\u1004\u103a\u101e\u1031\u102c\u1000\u103c\u1031\u102c\u1004\u1037\u103a \u1024 MCB \u101e\u100a\u103a \u1005\u1000\u103a\u1019\u103e\u102f\u104a \u1000\u1030\u1038\u101e\u1014\u103a\u1038\u101b\u1031\u102c\u1004\u103a\u1038\u101d\u101a\u103a\u101b\u1031\u1038\u1014\u103e\u1004\u1037\u103a \u101c\u1030\u1014\u1031\u1021\u102d\u1019\u103a\u1010\u1015\u103a\u1006\u1004\u103a\u1019\u103e\u102f\u1019\u103b\u102c\u1038\u1021\u1010\u103d\u1000\u103a \u101a\u102f\u1036\u1000\u103c\u100a\u103a\u1005\u102d\u1010\u103a\u1001\u103b\u101b\u101e\u1031\u102c\u1000\u102c\u1000\u103d\u101a\u103a\u1019\u103e\u102f\u1000\u102d\u102f\u101e\u1031\u1001\u103b\u102c\u1005\u1031\u101e\u100a\u103a\u104b 50mm\u00b2 \u1021\u1011\u102d\u101b\u103e\u102d\u101e\u1031\u102c\u1015\u103c\u1031\u102c\u1004\u103a\u1038\u101c\u103d\u101a\u103a\u1015\u103c\u1004\u103a\u101c\u103d\u101a\u103a\u1001\u103b\u102d\u1010\u103a\u1006\u1000\u103a\u1014\u102d\u102f\u1004\u103a\u1019\u103e\u102f\u104a 20mm terminal height \u1014\u103e\u1004\u1037\u103a\u101c\u103d\u101a\u103a\u1000\u1030\u101e\u1031\u102c DIN rail mounting \u1010\u102d\u102f\u1037\u1000\u103c\u1031\u102c\u1004\u1037\u103a circuit protection \u101c\u102d\u102f\u1021\u1015\u103a\u1001\u103b\u1000\u103a\u1021\u1019\u103b\u102d\u102f\u1038\u1019\u103b\u102d\u102f\u1038\u1021\u1010\u103d\u1000\u103a\u1021\u1000\u1031\u102c\u1004\u103a\u1038\u1006\u102f\u1036\u1038\u1016\u103c\u1005\u103a\u101e\u100a\u103a\u104b \u1024\u1000\u102d\u101b\u102d\u101a\u102c\u101e\u100a\u103a 50\/60Hz \u1010\u103d\u1004\u103a\u1011\u102d\u101b\u1031\u102c\u1000\u103a\u1005\u103d\u102c\u101c\u100a\u103a\u1015\u1010\u103a\u1014\u102d\u102f\u1004\u103a\u1015\u103c\u102e\u1038\u1015\u103c\u100a\u1037\u103a\u1005\u102f\u1036\u101e\u1031\u102c overload current protection characteristics \u1000\u102d\u102f\u1015\u1031\u1038\u101e\u1031\u102c\u1000\u103c\u1031\u102c\u1004\u1037\u103a\u1019\u1010\u1030\u100a\u102e\u101e\u1031\u102c\u1021\u1006\u1031\u102c\u1000\u103a\u1021\u1026 application \u1019\u103b\u102c\u1038\u1010\u103d\u1004\u103a\u1019\u1000\u103c\u102c\u1001\u100f\u1015\u103c\u1031\u102c\u1004\u103a\u1038\u101c\u1032\u1001\u103c\u1004\u103a\u1038\u1019\u101b\u103e\u102d\u101e\u1031\u102c\u101c\u102f\u1015\u103a\u1006\u1031\u102c\u1004\u103a\u1019\u103e\u102f\u1019\u103b\u102c\u1038\u1021\u1010\u103d\u1000\u103a\u101e\u1004\u1037\u103a\u1010\u1031\u102c\u103a\u101e\u100a\u103a\u104b.<\/p>\n<\/div>\n<\/div>","protected":false},"featured_media":5566,"comment_status":"closed","ping_status":"closed","template":"","meta":{"inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[],"product_cat":[116,130],"product_tag":[],"class_list":{"0":"post-5565","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-low-voltage-protection-devices","7":"product_cat-mcb","8":"desktop-align-left","9":"tablet-align-left","10":"mobile-align-left","12":"first","13":"instock","14":"shipping-taxable","15":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/test.viox.com\/my\/wp-json\/wp\/v2\/product\/5565","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/test.viox.com\/my\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/test.viox.com\/my\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/test.viox.com\/my\/wp-json\/wp\/v2\/comments?post=5565"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/test.viox.com\/my\/wp-json\/wp\/v2\/media\/5566"}],"wp:attachment":[{"href":"https:\/\/test.viox.com\/my\/wp-json\/wp\/v2\/media?parent=5565"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/test.viox.com\/my\/wp-json\/wp\/v2\/product_brand?post=5565"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/test.viox.com\/my\/wp-json\/wp\/v2\/product_cat?post=5565"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/test.viox.com\/my\/wp-json\/wp\/v2\/product_tag?post=5565"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}