{"id":5559,"date":"2024-09-13T14:49:20","date_gmt":"2024-09-13T06:49:20","guid":{"rendered":"https:\/\/viox.com\/?post_type=product&#038;p=5559"},"modified":"2024-09-13T14:49:20","modified_gmt":"2024-09-13T06:49:20","slug":"viox-vm7-125-2-1-4p-1-125a-10ka-low-voltage-mcb","status":"publish","type":"product","link":"https:\/\/test.viox.com\/my\/product\/viox-vm7-125-2-1-4p-1-125a-10ka-low-voltage-mcb\/","title":{"rendered":"VIOX VM7-125-2 1-4P 1-125A 10kA \u1021\u1014\u102d\u1019\u1037\u103a\u1017\u102d\u102f\u1037\u1021\u102c\u1038 MCB"},"content":{"rendered":"<div class=\"product-intro\">\n<h2>VIOX VM7-125-2 1-4P 1-125A 10kA \u1017\u102d\u102f\u1037\u1021\u102c\u1038\u1014\u102d\u1019\u1037\u103a MCB Miniature Circuit Breaker<\/h2>\n<h2>\u1001\u103c\u102f\u1036\u1004\u102f\u1036\u101e\u102f\u1036\u1038\u101e\u1015\u103a\u1001\u103b\u1000\u103a<\/h2>\n<p>VIOX VM7-125-2 series miniature circuit breaker \u101e\u100a\u103a rated working frequency 50Hz\/60Hz, rated working voltage AC240\/400V \u1014\u103e\u1004\u1037\u103a rated current 125A \u1021\u1011\u102d\u101b\u103e\u102d\u101e\u1031\u102c distribution lines \u1019\u103b\u102c\u1038\u1021\u1010\u103d\u1000\u103a \u1012\u102e\u1007\u102d\u102f\u1004\u103a\u1038\u1011\u102f\u1010\u103a\u1011\u102c\u1038\u101e\u1031\u102c \u1005\u103d\u1019\u103a\u1038\u1006\u1031\u102c\u1004\u103a\u101b\u100a\u103a\u1019\u103c\u1004\u1037\u103a\u1000\u102d\u101b\u102d\u101a\u102c\u1010\u1005\u103a\u1001\u102f\u1016\u103c\u1005\u103a\u101e\u100a\u103a\u104b \u1024 MCB \u101e\u100a\u103a \u1021\u101b\u1031\u1038\u1000\u103c\u102e\u1038\u101e\u1031\u102c\u1021\u1006\u1031\u102c\u1000\u103a\u1021\u1021\u102f\u1036\u1019\u103b\u102c\u1038\u1014\u103e\u1004\u1037\u103a \u1021\u101c\u102c\u1038\u1010\u1030\u1015\u1010\u103a\u101d\u1014\u103a\u1038\u1000\u103b\u1004\u103a\u1019\u103b\u102c\u1038\u101b\u103e\u102d power line facilities \u1019\u103b\u102c\u1038\u1014\u103e\u1004\u1037\u103a \u1021\u101b\u1031\u1038\u1000\u103c\u102e\u1038\u101e\u1031\u102c\u101c\u103b\u103e\u1015\u103a\u1005\u1005\u103a\u1015\u1005\u1039\u1005\u100a\u103a\u1038\u1019\u103b\u102c\u1038\u1021\u1010\u103d\u1000\u103a \u101e\u102c\u101c\u103d\u1014\u103a\u1000\u1031\u102c\u1004\u103a\u1038\u1019\u103d\u1014\u103a\u101e\u1031\u102c\u1000\u102c\u1000\u103d\u101a\u103a\u1019\u103e\u102f\u1000\u102d\u102f \u1015\u1031\u1038\u1015\u102b\u101e\u100a\u103a\u104b \u104e\u1004\u103a\u1038\u1000\u102d\u102f \u1019\u1000\u103c\u102c\u1001\u100f on-off operations \u1019\u103b\u102c\u1038\u1021\u1010\u103d\u1000\u103a\u101c\u100a\u103a\u1038 \u1021\u101e\u102f\u1036\u1038\u1015\u103c\u102f\u1014\u102d\u102f\u1004\u103a\u1015\u103c\u102e\u1038 isolation \u101b\u100a\u103a\u101b\u103d\u101a\u103a\u1001\u103b\u1000\u103a\u1019\u103b\u102c\u1038\u1021\u1010\u103d\u1000\u103a\u101c\u100a\u103a\u1038 \u101e\u1004\u1037\u103a\u101c\u103b\u1031\u102c\u103a\u1015\u102b\u101e\u100a\u103a\u104b.<\/p>\n<h2>\u1021\u1013\u102d\u1000\u1021\u1004\u103a\u1039\u1002\u102b\u101b\u1015\u103a\u1019\u103b\u102c\u1038<\/h2>\n<ul>\n<li>\u101c\u1000\u103a\u101b\u103e\u102d\u1021\u1006\u1004\u1037\u103a\u1021\u102c\u1038\u101c\u102f\u1036\u1038\u1021\u1010\u103d\u1000\u103a 10kA \u1019\u103c\u1004\u1037\u103a\u1019\u102c\u1038\u101e\u1031\u102c rated short-circuit breaking capacity<\/li>\n<li>\u1015\u102d\u102f\u1019\u102d\u102f\u1000\u1031\u102c\u1004\u103a\u1038\u1019\u103d\u1014\u103a\u101e\u1031\u102c\u101c\u102f\u1036\u1001\u103c\u102f\u1036\u101b\u1031\u1038\u1021\u1010\u103d\u1000\u103a \u1021\u1014\u102e\u101b\u1031\u102c\u1004\u103a\u1014\u103e\u1004\u1037\u103a \u1021\u1005\u102d\u1019\u103a\u1038\u101b\u1031\u102c\u1004\u103a \u101c\u102f\u1036\u1001\u103c\u102f\u1036\u101b\u1031\u1038\u1021\u100a\u103d\u103e\u1014\u103a\u1038\u1019\u103b\u102c\u1038<\/li>\n<li>\u101c\u103b\u1004\u103a\u1019\u103c\u1014\u103a\u101e\u1031\u102c contact closure \u1021\u1010\u103d\u1000\u103a \u1005\u103d\u1019\u103a\u1038\u1021\u1004\u103a\u101e\u102d\u102f\u101c\u103e\u1031\u102c\u1004\u103a\u1019\u103e\u102f\u101a\u1014\u1039\u1010\u101b\u102c\u1038\u101e\u100a\u103a \u1011\u102f\u1010\u103a\u1000\u102f\u1014\u103a\u101e\u1000\u103a\u1010\u1019\u103a\u1038\u1000\u102d\u102f \u1010\u102d\u102f\u1038\u1010\u1000\u103a\u1005\u1031\u101e\u100a\u103a\u104b<\/li>\n<li>AX-1 \u1000\u1032\u1037\u101e\u102d\u102f\u1037\u101e\u1031\u102c \u1021\u1019\u103b\u102d\u102f\u1038\u1019\u103b\u102d\u102f\u1038\u101e\u1031\u102c modular accessories \u1019\u103b\u102c\u1038\u1014\u103e\u1004\u1037\u103a \u1010\u103d\u1032\u1016\u1000\u103a\u1021\u101e\u102f\u1036\u1038\u1015\u103c\u102f\u1014\u102d\u102f\u1004\u103a\u101e\u100a\u103a\u104b<\/li>\n<li>GB\/T14048.2 \u1014\u103e\u1004\u1037\u103a IEC60947-2 \u1005\u1036\u1001\u103b\u102d\u1014\u103a\u1005\u1036\u100a\u103d\u103e\u1014\u103a\u1038\u1019\u103b\u102c\u1038\u1014\u103e\u1004\u1037\u103a\u1000\u102d\u102f\u1000\u103a\u100a\u102e\u101e\u100a\u103a\u104b<\/li>\n<\/ul>\n<h2>\u1014\u100a\u103a\u1038\u1015\u100a\u102c\u1006\u102d\u102f\u1004\u103a\u101b\u102c\u101e\u1010\u103a\u1019\u103e\u1010\u103a\u1001\u103b\u1000\u103a\u1019\u103b\u102c\u1038<\/h2>\n<ul>\n<li>Product shelf current: 125A<\/li>\n<li>Rated insulation voltage (Ui): 1000V<\/li>\n<li>Rated impulse withstand voltage (Uimp): 6kV<\/li>\n<li>Rated current: 16A, 20A, 25A, 32A, 40A, 50A, 63A, 80A, 100A, 125A<\/li>\n<li>Rated voltage: 240\/400V (1P, 2P), 400V (2P, 3P, 4P)<\/li>\n<li>\u1021\u1006\u1004\u1037\u103a\u101e\u1010\u103a\u1019\u103e\u1010\u103a\u1011\u102c\u1038\u101e\u1031\u102c \u1000\u103c\u102d\u1019\u103a\u1014\u103e\u102f\u1014\u103a\u1038- 50\/60Hz<\/li>\n<li>Tripping curve: C: 8In\u00b120%, D: 12In\u00b120%<\/li>\n<li>Number of poles: 1P, 2P, 3P, 4P<\/li>\n<li>Unipolar width: 27mm<\/li>\n<li>Ultimate short-circuit breaking capacity (Icu): 10kA<\/li>\n<li>Operating short-circuit breaking capacity (Ics): 7.5kA<\/li>\n<li>Reference temperature: 30\u00b0C<\/li>\n<li>Usage Category: A<\/li>\n<\/ul>\n<h2>\u1005\u103d\u1019\u103a\u1038\u1006\u1031\u102c\u1004\u103a\u101b\u100a\u103a \u101c\u1000\u1039\u1001\u100f\u102c\u1019\u103b\u102c\u1038<\/h2>\n<ul>\n<li>Mechanical life: 20,000 cycles<\/li>\n<li>Electrical lifespan: 6,000 cycles<\/li>\n<\/ul>\n<h2>\u1001\u101c\u102f\u1010\u103a\u1010\u102d\u102f\u1000\u103a\u1001\u103c\u1004\u103a\u1038 \u101c\u1000\u1039\u1001\u100f\u102c\u1019\u103b\u102c\u1038<\/h2>\n<table border=\"1\" cellpadding=\"5\">\n<tbody>\n<tr>\n<th>\u1021\u1006\u1004\u1037\u103a\u101e\u1010\u103a\u1019\u103e\u1010\u103a\u1011\u102c\u1038\u101e\u1031\u102c \u101c\u1000\u103a\u101b\u103e\u102d (A)<\/th>\n<th>Overload Tripping Characteristics<\/th>\n<th>Instantaneous Tripping Characteristics (A)<\/th>\n<\/tr>\n<tr>\n<td>In \u2264 125<\/td>\n<td>1.05In agreed non-tripping time 1h (cold state)<br \/>\n1.30In agreed tripping time 1h (hot state)<\/td>\n<td rowspan=\"2\">10In\u00b120%<\/td>\n<\/tr>\n<tr>\n<td>In &gt; 125<\/td>\n<td>1.05In agreed non-tripping time 2h (cold state)<br \/>\n1.30In agreed tripping time 2h (hot state)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>\u1021\u101e\u102f\u1036\u1038\u1001\u103b\u1019\u103e\u102f<\/h2>\n<ul>\n<li>Power line facilities \u1019\u103b\u102c\u1038\u1021\u102c\u1038 \u1000\u102c\u1000\u103d\u101a\u103a\u1001\u103c\u1004\u103a\u1038<\/li>\n<li>\u1021\u101b\u1031\u1038\u1000\u103c\u102e\u1038\u101e\u1031\u102c \u101c\u103b\u103e\u1015\u103a\u1005\u1005\u103a\u1015\u1005\u1039\u1005\u100a\u103a\u1038 \u1000\u102c\u1000\u103d\u101a\u103a\u1001\u103c\u1004\u103a\u1038<\/li>\n<li>\u1021\u101b\u1031\u1038\u1000\u103c\u102e\u1038\u101e\u1031\u102c \u1021\u1006\u1031\u102c\u1000\u103a\u1021\u1021\u102f\u1036\u1019\u103b\u102c\u1038\u101b\u103e\u102d Distribution systems \u1019\u103b\u102c\u1038<\/li>\n<li>\u1019\u1000\u103c\u102c\u1001\u100f on-off operations \u1019\u103b\u102c\u1038<\/li>\n<li>\u101c\u103b\u103e\u1015\u103a\u1005\u1005\u103a\u1021\u1011\u102e\u1038\u1000\u103b\u1014\u103a<\/li>\n<\/ul>\n<h2>\u1018\u1031\u1038\u1000\u1004\u103a\u1038\u101b\u1031\u1038\u1021\u1004\u103a\u1039\u1002\u102b\u101b\u1015\u103a\u1019\u103b\u102c\u1038<\/h2>\n<ul>\n<li>\u1019\u103c\u1004\u1037\u103a\u1019\u102c\u1038\u101e\u1031\u102c short-circuit breaking capacity<\/li>\n<li>Dual-color \u101c\u102f\u1036\u1001\u103c\u102f\u1036\u101b\u1031\u1038\u1021\u100a\u103d\u103e\u1014\u103a\u1038\u1019\u103b\u102c\u1038<\/li>\n<li>\u1010\u101e\u1019\u1010\u103a\u1010\u100a\u103a\u1038\u101c\u100a\u103a\u1015\u1010\u103a\u1019\u103e\u102f\u1021\u1010\u103d\u1000\u103a \u1005\u103d\u1019\u103a\u1038\u1021\u1004\u103a\u101e\u102d\u102f\u101c\u103e\u1031\u102c\u1004\u103a\u1019\u103e\u102f\u101a\u1014\u1039\u1010\u101b\u102c\u1038<\/li>\n<\/ul>\n<h2>\u1021\u101e\u103d\u1004\u103a\u1021\u1015\u103c\u1004\u103a\u1019\u103b\u1009\u103a\u1038\u1000\u103d\u1031\u1038<\/h2>\n<p><a href=\"https:\/\/test.viox.com\/my\/?attachment_id=5560\" rel=\"attachment wp-att-5560\"><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone  wp-image-5560\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VM7-125-2-1-4P-1-125A-10kA-Low-Voltage-MCB-Miniature-Circuit-Breaker02.webp\" alt=\"\" width=\"732\" height=\"264\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VM7-125-2-1-4P-1-125A-10kA-Low-Voltage-MCB-Miniature-Circuit-Breaker02.webp 1292w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VM7-125-2-1-4P-1-125A-10kA-Low-Voltage-MCB-Miniature-Circuit-Breaker02-300x108.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VM7-125-2-1-4P-1-125A-10kA-Low-Voltage-MCB-Miniature-Circuit-Breaker02-1024x369.webp 1024w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VM7-125-2-1-4P-1-125A-10kA-Low-Voltage-MCB-Miniature-Circuit-Breaker02-768x277.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VM7-125-2-1-4P-1-125A-10kA-Low-Voltage-MCB-Miniature-Circuit-Breaker02-600x216.webp 600w\" sizes=\"(max-width: 732px) 100vw, 732px\" \/><\/a><\/p>\n<h2>\u1021\u1010\u102d\u102f\u1004\u103a\u1038\u1021\u1010\u102c<\/h2>\n<p><a href=\"https:\/\/test.viox.com\/my\/?attachment_id=5561\" rel=\"attachment wp-att-5561\"><img decoding=\"async\" class=\"alignnone  wp-image-5561\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VM7-125-2-1-4P-1-125A-10kA-Low-Voltage-MCB-Miniature-Circuit-Breaker03.webp\" alt=\"\" width=\"765\" height=\"216\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VM7-125-2-1-4P-1-125A-10kA-Low-Voltage-MCB-Miniature-Circuit-Breaker03.webp 1502w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VM7-125-2-1-4P-1-125A-10kA-Low-Voltage-MCB-Miniature-Circuit-Breaker03-300x85.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VM7-125-2-1-4P-1-125A-10kA-Low-Voltage-MCB-Miniature-Circuit-Breaker03-1024x289.webp 1024w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VM7-125-2-1-4P-1-125A-10kA-Low-Voltage-MCB-Miniature-Circuit-Breaker03-768x217.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VM7-125-2-1-4P-1-125A-10kA-Low-Voltage-MCB-Miniature-Circuit-Breaker03-600x169.webp 600w\" sizes=\"(max-width: 765px) 100vw, 765px\" \/><\/a><\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<div class=\"msg-content MuiBox-root css-0\">\n<div class=\"break-words\">\n<p>VIOX VM7-125-2 MCB \u101e\u100a\u103a 125A \u1021\u1011\u102d \u101c\u103b\u103e\u1015\u103a\u1005\u1005\u103a\u1005\u1014\u1005\u103a\u1019\u103b\u102c\u1038\u1021\u1010\u103d\u1000\u103a \u1001\u102d\u102f\u1004\u103a\u1019\u102c\u101e\u1031\u102c\u1000\u102c\u1000\u103d\u101a\u103a\u1019\u103e\u102f\u1015\u1031\u1038\u1015\u102b\u101e\u100a\u103a\u104b \u1024 GB\/T14048.2 \u1014\u103e\u1004\u1037\u103a IEC60947-2 \u1005\u1036\u1001\u103b\u102d\u1014\u103a\u1005\u1036\u100a\u103d\u103e\u1014\u103a\u1038\u1019\u103b\u102c\u1038\u1014\u103e\u1004\u1037\u103a\u1000\u102d\u102f\u1000\u103a\u100a\u102e\u101e\u1031\u102c\u1000\u102d\u101b\u102d\u101a\u102c\u101e\u100a\u103a 10kA ultimate breaking capacity \u1015\u102b\u101b\u103e\u102d\u1015\u103c\u102e\u1038 240\/400V AC \u1010\u103d\u1004\u103a 16A \u1019\u103e 125A \u1021\u1011\u102d \u1021\u1019\u103b\u102d\u102f\u1038\u1019\u103b\u102d\u102f\u1038\u101e\u1031\u102c current ratings \u1019\u103b\u102c\u1038\u1000\u102d\u102f \u1021\u1011\u1031\u102c\u1000\u103a\u1021\u1015\u1036\u1037\u1015\u1031\u1038\u1015\u102b\u101e\u100a\u103a\u104b 1P, 2P, 3P \u1014\u103e\u1004\u1037\u103a 4P configurations \u1019\u103b\u102c\u1038\u1016\u103c\u1004\u1037\u103a\u101b\u101b\u103e\u102d\u1014\u102d\u102f\u1004\u103a\u1015\u103c\u102e\u1038 C \u1014\u103e\u1004\u1037\u103a D tripping curves \u1019\u103b\u102c\u1038\u1000\u102d\u102f \u1018\u1000\u103a\u1005\u102f\u1036\u101e\u102f\u1036\u1038\u1014\u102d\u102f\u1004\u103a\u101e\u1031\u102c applications \u1019\u103b\u102c\u1038\u1021\u1010\u103d\u1000\u103a \u1015\u1036\u1037\u1015\u102d\u102f\u1038\u1015\u1031\u1038\u1015\u102b\u101e\u100a\u103a\u104b \u1021\u1013\u102d\u1000\u1021\u102c\u1038\u101e\u102c\u1001\u103b\u1000\u103a\u1019\u103b\u102c\u1038\u1019\u103e\u102c 6kV impulse withstand voltage, \u1021\u1014\u102e\/\u1021\u1005\u102d\u1019\u103a\u1038\u101b\u1031\u102c\u1004\u103a \u101c\u102f\u1036\u1001\u103c\u102f\u1036\u101b\u1031\u1038\u1021\u100a\u103d\u103e\u1014\u103a\u1038\u1019\u103b\u102c\u1038\u1014\u103e\u1004\u1037\u103a \u101e\u1000\u103a\u1010\u1019\u103a\u1038\u1015\u102d\u102f\u1019\u102d\u102f\u1000\u1031\u102c\u1004\u103a\u1038\u1019\u103d\u1014\u103a\u1005\u1031\u101b\u1014\u103a\u1021\u1010\u103d\u1000\u103a \u1005\u103d\u1019\u103a\u1038\u1021\u1004\u103a\u101e\u102d\u102f\u101c\u103e\u1031\u102c\u1004\u103a\u1019\u103e\u102f\u101a\u1014\u1039\u1010\u101b\u102c\u1038\u1010\u102d\u102f\u1037\u1015\u102b\u101d\u1004\u103a\u101e\u100a\u103a\u104b 20,000 cycle mechanical life \u1014\u103e\u1004\u1037\u103a 6,000 cycle electrical life \u1010\u102d\u102f\u1037\u1016\u103c\u1004\u1037\u103a \u1024 MCB \u101e\u100a\u103a \u1021\u101b\u1031\u1038\u1000\u103c\u102e\u1038\u101e\u1031\u102c\u1015\u1005\u1039\u1005\u100a\u103a\u1038\u1019\u103b\u102c\u1038\u1014\u103e\u1004\u1037\u103a power line facilities \u1019\u103b\u102c\u1038\u1021\u1010\u103d\u1000\u103a \u101a\u102f\u1036\u1000\u103c\u100a\u103a\u1005\u102d\u1010\u103a\u1001\u103b\u101b\u101e\u1031\u102c\u1000\u102c\u1000\u103d\u101a\u103a\u1019\u103e\u102f\u1000\u102d\u102f \u101e\u1031\u1001\u103b\u102c\u1005\u1031\u1015\u102b\u101e\u100a\u103a\u104b \u104e\u1004\u103a\u1038\u104f modular accessories \u1019\u103b\u102c\u1038\u1014\u103e\u1004\u1037\u103a 27mm unipolar width \u1010\u102d\u102f\u1037\u1014\u103e\u1004\u1037\u103a \u1010\u103d\u1032\u1016\u1000\u103a\u1021\u101e\u102f\u1036\u1038\u1015\u103c\u102f\u1014\u102d\u102f\u1004\u103a\u1019\u103e\u102f\u101e\u100a\u103a \u1021\u101b\u1031\u1038\u1000\u103c\u102e\u1038\u101e\u1031\u102c\u1021\u1006\u1031\u102c\u1000\u103a\u1021\u1021\u102f\u1036\u1019\u103b\u102c\u1038\u101b\u103e\u102d \u1021\u1019\u103b\u102d\u102f\u1038\u1019\u103b\u102d\u102f\u1038\u101e\u1031\u102c distribution systems \u1019\u103b\u102c\u1038\u1021\u1010\u103d\u1000\u103a \u1021\u1000\u1031\u102c\u1004\u103a\u1038\u1006\u102f\u1036\u1038\u1016\u103c\u1005\u103a\u101e\u100a\u103a\u104b \u1024\u1000\u102d\u101b\u102d\u101a\u102c\u101e\u100a\u103a 50\/60Hz \u1010\u103d\u1004\u103a \u1011\u102d\u101b\u1031\u102c\u1000\u103a\u1005\u103d\u102c\u101c\u100a\u103a\u1015\u1010\u103a\u1014\u102d\u102f\u1004\u103a\u1015\u103c\u102e\u1038 \u1015\u103c\u100a\u1037\u103a\u1005\u102f\u1036\u101e\u1031\u102c circuit protection \u1021\u1010\u103d\u1000\u103a overload \u1014\u103e\u1004\u1037\u103a instantaneous tripping characteristics \u1014\u103e\u1005\u103a\u1019\u103b\u102d\u102f\u1038\u101c\u102f\u1036\u1038\u1000\u102d\u102f \u1015\u1031\u1038\u1015\u102b\u101e\u100a\u103a\u104b.<\/p>\n<\/div>\n<\/div>","protected":false},"featured_media":5562,"comment_status":"closed","ping_status":"closed","template":"","meta":{"inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[],"product_cat":[116,130],"product_tag":[],"class_list":{"0":"post-5559","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-low-voltage-protection-devices","7":"product_cat-mcb","8":"desktop-align-left","9":"tablet-align-left","10":"mobile-align-left","12":"first","13":"instock","14":"shipping-taxable","15":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/test.viox.com\/my\/wp-json\/wp\/v2\/product\/5559","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/test.viox.com\/my\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/test.viox.com\/my\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/test.viox.com\/my\/wp-json\/wp\/v2\/comments?post=5559"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/test.viox.com\/my\/wp-json\/wp\/v2\/media\/5562"}],"wp:attachment":[{"href":"https:\/\/test.viox.com\/my\/wp-json\/wp\/v2\/media?parent=5559"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/test.viox.com\/my\/wp-json\/wp\/v2\/product_brand?post=5559"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/test.viox.com\/my\/wp-json\/wp\/v2\/product_cat?post=5559"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/test.viox.com\/my\/wp-json\/wp\/v2\/product_tag?post=5559"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}