{"id":5465,"date":"2024-09-12T15:13:20","date_gmt":"2024-09-12T07:13:20","guid":{"rendered":"https:\/\/viox.com\/?post_type=product&#038;p=5465"},"modified":"2024-09-12T15:17:32","modified_gmt":"2024-09-12T07:17:32","slug":"viox-vsp1-d20-1s1-pluggable-single-pole-spd","status":"publish","type":"product","link":"https:\/\/test.viox.com\/ms\/product\/viox-vsp1-d20-1s1-pluggable-single-pole-spd\/","title":{"rendered":"VIOX VSP1-D20\/1(S)+1 SPD Kutub Tunggal Boleh Palam"},"content":{"rendered":"<div class=\"product-intro\">\n<h2>VIOX VSP1-D20\/1(S)+1 Pluggable Single-Pole SPD<\/h2>\n<h2>Overview<\/h2>\n<p>The VIOX VSP1-D20\/1(S)+1 is a high-performance Pluggable Single-Pole Surge Protective Device (SPD) designed for use in sub-distribution boards. This versatile device offers robust protection for L-N and N-PE modes, making it an ideal solution for various electrical installations.<\/p>\n<h2>Key Features<\/h2>\n<ul>\n<li>Class II, Class III, Type 2, Type 3 device<\/li>\n<li>Location of Use: Sub-Distribution Boards<\/li>\n<li>Mode of Protection: L-N, N-PE<\/li>\n<li>Surge Ratings: In = 10 kA (8\/20 \u03bcs)<\/li>\n<li>IEC\/EN\/UL Category: Class II+III \/ Type 2+3<\/li>\n<li>Protective Elements: High Energy MOV and GDT<\/li>\n<li>Housing: Pluggable Design<\/li>\n<li>Compliance: IEC 61643-11:2011, EN 61643-11:2012<\/li>\n<\/ul>\n<h2>Technical Specifications<\/h2>\n<table border=\"1\" cellpadding=\"5\">\n<tbody>\n<tr>\n<th>IEC Electrical<\/th>\n<th>75<\/th>\n<th>150<\/th>\n<th>275<\/th>\n<th>320<\/th>\n<th>385<\/th>\n<th>440<\/th>\n<\/tr>\n<tr>\n<td>Nominal AC Voltage (50\/60Hz)<\/td>\n<td>60 V<\/td>\n<td>120 V<\/td>\n<td>230 V<\/td>\n<td>230 V<\/td>\n<td>230 V<\/td>\n<td>400 V<\/td>\n<\/tr>\n<tr>\n<td>Maximum Continuous Operating Voltage (AC) (L-N)<\/td>\n<td>75 V<\/td>\n<td>150 V<\/td>\n<td>275V<\/td>\n<td>320 V<\/td>\n<td>385 V<\/td>\n<td>440 V<\/td>\n<\/tr>\n<tr>\n<td>Maximum Continuous Operating Voltage (AC) (N-PE)<\/td>\n<td colspan=\"6\">255V<\/td>\n<\/tr>\n<tr>\n<td>Nominal Discharge Current (8\/20 \u03bcs) (L-N) \/ (N-PE)<\/td>\n<td colspan=\"6\">10kV \/ 10kA<\/td>\n<\/tr>\n<tr>\n<td>Maximum Discharge Current (8\/20 \u03bcs) (L-N) \/ (N-PE)<\/td>\n<td colspan=\"6\">20 kA \/ 20 kA<\/td>\n<\/tr>\n<tr>\n<td>Voltage Protection Level (L-N) \/ (N-PE)<\/td>\n<td>0.2kV\/1.5kV<\/td>\n<td>0.6kV\/1.5kV<\/td>\n<td>1.3kV\/1.5kV<\/td>\n<td>1.5kV\/1.5kV<\/td>\n<td>1.5kV\/1.5kV<\/td>\n<td>1.8kV\/1.5kV<\/td>\n<\/tr>\n<tr>\n<td>Follow Current Interrupt Rating (N-PE)<\/td>\n<td colspan=\"6\">100Arms<\/td>\n<\/tr>\n<tr>\n<td>Response Time (L-N) \/ (N-PE)<\/td>\n<td colspan=\"6\">&lt; 25 ns \/ &lt; 100 ns<\/td>\n<\/tr>\n<tr>\n<td>Back-Up Fuse (max)<\/td>\n<td colspan=\"6\">125 A gL \/ gG<\/td>\n<\/tr>\n<tr>\n<td>Short-Circuit Current Rating (AC) (L-N)<\/td>\n<td colspan=\"6\">10 kA<\/td>\n<\/tr>\n<tr>\n<td>TOV Withstand 5s (L-N)<\/td>\n<td>90V<\/td>\n<td>180V<\/td>\n<td>335V<\/td>\n<td>335V<\/td>\n<td>335V<\/td>\n<td>580V<\/td>\n<\/tr>\n<tr>\n<td>TOV 120min (L-N)<\/td>\n<td>115V<\/td>\n<td>230V<\/td>\n<td>440V<\/td>\n<td>440V<\/td>\n<td>440V<\/td>\n<td>765V<\/td>\n<\/tr>\n<tr>\n<td>mode<\/td>\n<td>Withstand<\/td>\n<td>Withstand<\/td>\n<td>Safe Fail<\/td>\n<td>Safe Fail<\/td>\n<td>Safe Fail<\/td>\n<td>Safe Fail<\/td>\n<\/tr>\n<tr>\n<td>TOV Withstand 200ms (N-PE)<\/td>\n<td colspan=\"6\">1200V<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Mechanical &amp; Environmental Specifications<\/h2>\n<ul>\n<li>Operating Temperature Range: -40\u00b0F to +158\u00b0F [-40\u00b0C to +70\u00b0C]<\/li>\n<li>Permissible Operating Humidity: 5%&#8230;95%<\/li>\n<li>Atmospheric pressure and altitude: 80k Pa &#8230; 106k Pa \/ -500 m&#8230;.2000 m<\/li>\n<li>Terminal Screw Torque: 39.9 lbf.in [4.5 Nm]<\/li>\n<li>Conductor Cross Section (max): 2 AWG (Solid, Stranded) \/ 4 AWG (Flexible)<\/li>\n<li>35 mm\u00b2 (Solid, Stranded) \/ 25 mm\u00b2(Flexible)<\/li>\n<li>Mounting: 35 mm DIN Rail, EN 60715<\/li>\n<li>Degree of Protection: IP 20 (built-in)<\/li>\n<li>Housing Material: Thermoplastic: Extinguishing Degree UL 94 V-0<\/li>\n<li>Thermal Protection: Yes<\/li>\n<li>Operating State \/ Fault Indication: Green ok \/ Red defect<\/li>\n<\/ul>\n<h2>Additional Features<\/h2>\n<ul>\n<li>Remote Contacts (RC): Optional<\/li>\n<li>RC Switching Capacity: AC: 250V \/ 0.5 A; DC: 250V \/ 0.1 A; 125 V \/ 0.2 A; 75 V \/ 0.5 A<\/li>\n<li>RC Conductor Cross Section (max): 16 AWG (Solid) \/ 1.5 mm\u00b2(Solid)<\/li>\n<\/ul>\n<h2>Internal Configuration<\/h2>\n<p><a href=\"https:\/\/test.viox.com\/?attachment_id=5469\" rel=\"attachment wp-att-5469\"><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone wp-image-5469 size-full\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VSP1-D20_1S1-Pluggable-Single-Pole-SPD04.webp\" alt=\" Internal Configuration OF VIOX VSP1-D20_1(S)+1 Pluggable Single-Pole SPD\" width=\"332\" height=\"370\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VSP1-D20_1S1-Pluggable-Single-Pole-SPD04.webp 332w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VSP1-D20_1S1-Pluggable-Single-Pole-SPD04-269x300.webp 269w\" sizes=\"(max-width: 332px) 100vw, 332px\" \/><\/a><\/p>\n<h2>Dimension<\/h2>\n<p><a href=\"https:\/\/test.viox.com\/?attachment_id=5467\" rel=\"attachment wp-att-5467\"><img decoding=\"async\" class=\"alignnone size-full wp-image-5467\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VSP1-D20_1S1-Pluggable-Single-Pole-SPD03.webp\" alt=\"Dimension of VIOX VSP1-D20_1(S)+1 Pluggable Single-Pole SPD\" width=\"696\" height=\"368\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VSP1-D20_1S1-Pluggable-Single-Pole-SPD03.webp 696w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VSP1-D20_1S1-Pluggable-Single-Pole-SPD03-300x159.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VSP1-D20_1S1-Pluggable-Single-Pole-SPD03-600x317.webp 600w\" sizes=\"(max-width: 696px) 100vw, 696px\" \/><\/a><\/p>\n<h2>Connection Diagram<\/h2>\n<p><a href=\"https:\/\/test.viox.com\/?attachment_id=5468\" rel=\"attachment wp-att-5468\"><img decoding=\"async\" class=\"alignnone size-full wp-image-5468\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VSP1-D20_1S1-Pluggable-Single-Pole-SPD02.webp\" alt=\" Connection Diagram of VIOX VSP1-D20_1(S)+1 Pluggable Single-Pole SPD\" width=\"430\" height=\"462\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VSP1-D20_1S1-Pluggable-Single-Pole-SPD02.webp 430w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VSP1-D20_1S1-Pluggable-Single-Pole-SPD02-279x300.webp 279w\" sizes=\"(max-width: 430px) 100vw, 430px\" \/><\/a><\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<div class=\"msg-content MuiBox-root css-0\">\n<div class=\"break-words\">\n<p>VIOX VSP1-D20\/1(S)+1 SPD Satu Kutub Boleh Pasang menawarkan perlindungan lonjakan komprehensif untuk papan sub-agihan. Peranti Kelas II+III\/Jenis 2+3 ini melindungi mod L-N dan N-PE dengan arus discas nominal 10kA dan maksimum 20kA. Mempunyai elemen MOV dan GDT bertenaga tinggi, ia beroperasi dari 60V hingga 400V AC dengan masa tindak balas &lt;25ns untuk L-N dan &lt;100ns untuk N-PE. Mematuhi IEC 61643-11:2011 dan EN 61643-11:2012, ia menyediakan tahap perlindungan voltan dari 0.2kV hingga 1.8kV. Dengan perlindungan IP20, perlindungan terma, dan sesentuh jauh pilihan, SPD serba boleh ini sesuai untuk pelbagai pemasangan elektrik, menggabungkan kebolehpercayaan dan prestasi untuk perlindungan sistem kuasa yang dipertingkatkan dalam pelbagai aplikasi.<\/p>\n<\/div>\n<\/div>","protected":false},"featured_media":5466,"comment_status":"closed","ping_status":"closed","template":"","meta":{"inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[],"product_cat":[116,127],"product_tag":[],"class_list":{"0":"post-5465","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-low-voltage-protection-devices","7":"product_cat-surge-protector","8":"desktop-align-left","9":"tablet-align-left","10":"mobile-align-left","12":"first","13":"instock","14":"shipping-taxable","15":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/test.viox.com\/ms\/wp-json\/wp\/v2\/product\/5465","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/test.viox.com\/ms\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/test.viox.com\/ms\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/test.viox.com\/ms\/wp-json\/wp\/v2\/comments?post=5465"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/test.viox.com\/ms\/wp-json\/wp\/v2\/media\/5466"}],"wp:attachment":[{"href":"https:\/\/test.viox.com\/ms\/wp-json\/wp\/v2\/media?parent=5465"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/test.viox.com\/ms\/wp-json\/wp\/v2\/product_brand?post=5465"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/test.viox.com\/ms\/wp-json\/wp\/v2\/product_cat?post=5465"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/test.viox.com\/ms\/wp-json\/wp\/v2\/product_tag?post=5465"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}