{"id":21304,"date":"2026-01-16T23:59:50","date_gmt":"2026-01-16T15:59:50","guid":{"rendered":"https:\/\/viox.com\/?p=21304"},"modified":"2026-01-16T23:59:52","modified_gmt":"2026-01-16T15:59:52","slug":"load-center-vs-distribution-board-nema-iec-difference","status":"publish","type":"post","link":"https:\/\/test.viox.com\/ko\/load-center-vs-distribution-board-nema-iec-difference\/","title":{"rendered":"\ubd80\ud558 \uc911\uc2ec \ub300 \ubc30\uc804\ubc18: NEMA \ubc0f IEC \ud45c\uc900 \uac04 \ucc28\uc774\uc810 \uc774\ud574"},"content":{"rendered":"<div class=\"product-intro\">\n<p>\ucd5c\uadfc \uc720\ub7fd\uc758 \ud55c \uacc4\uc57d\uc5c5\uccb4\uac00 \ubd81\ubbf8 \uc81c\uc870 \uc2dc\uc124 \ud504\ub85c\uc81d\ud2b8\uc5d0 400V \ubc30\uc804\ubc18 \uc0ac\uc591\uc744 \uc81c\ucd9c\ud588\uc744 \ub54c, \uc870\ub2ec \ud300\uc740 \uc608\uc0c1\uce58 \ubabb\ud55c \ubb38\uc81c\uc5d0 \uc9c1\uba74\ud588\uc2b5\ub2c8\ub2e4. \ud604\uc9c0 \uc804\uae30 \uac80\uc0ac\uad00\uc774 UL 67 \ud45c\uc900\uc744 \uc900\uc218\ud558\uc9c0 \uc54a\uc558\ub2e4\ub294 \uc774\uc720\ub85c \uc7a5\ube44\ub97c \uac70\ubd80\ud55c \uac83\uc785\ub2c8\ub2e4. \uadfc\ubcf8\uc801\uc778 \uc6d0\uc778\uc740 \ubb34\uc5c7\uc774\uc5c8\uc744\uae4c\uc694? \u201c\ub85c\ub4dc \uc13c\ud130\u201d\uc640 \u201c\ubc30\uc804\ubc18\u201d \uac04\uc758 \uae30\ubcf8\uc801\uc778 \uc624\ud574\uc600\uc2b5\ub2c8\ub2e4. \uc774 \ub450 \uc6a9\uc5b4\ub294 \uae30\ub2a5\uc801\uc73c\ub85c \uc720\uc0ac\ud55c \uc7a5\ube44\ub97c \uc124\uba85\ud558\uc9c0\ub9cc \uc644\uc804\ud788 \ub2e4\ub978 \uaddc\uc81c \ud504\ub808\uc784\uc6cc\ud06c\uc758 \uc801\uc6a9\uc744 \ubc1b\uc2b5\ub2c8\ub2e4.<\/p>\n<p>\uc774\ub7ec\ud55c \uc2dc\ub098\ub9ac\uc624\ub294 \uc624\ub298\ub0a0\uc758 \uc138\uacc4\ud654\ub41c \uc804\uae30 \uc0b0\uc5c5\uc5d0\uc11c \uc790\uc8fc \ubc1c\uc0dd\ud569\ub2c8\ub2e4. \ud504\ub85c\uc81d\ud2b8\uac00 \ub300\ub959\uc5d0 \uac78\uccd0 \uc9c4\ud589\ub418\uace0 \uacf5\uae09\ub9dd\uc774 \uad6d\uacbd\uc744 \ub118\ub098\ub4e4\uba74\uc11c NEMA(National Electrical Manufacturers Association)\uc640 IEC(International Electrotechnical Commission) \ud45c\uc900 \uac04\uc758 \ucc28\uc774\ub294 \ub2e8\uc21c\ud55c \ud559\ubb38\uc801\uc778 \ubb38\uc81c\uac00 \uc544\ub2c8\ub77c \uc7a5\ube44 \uc120\ud0dd, \uaddc\uc815 \uc900\uc218 \ubc0f \ud504\ub85c\uc81d\ud2b8 \uc608\uc0b0\uc5d0 \uc9c1\uc811\uc801\uc778 \uc601\ud5a5\uc744 \ubbf8\uce69\ub2c8\ub2e4.<\/p>\n<p>\uc774\ub7ec\ud55c \ucc28\uc774\uc810\uc744 \uc774\ud574\ud558\ub294 \uac83\uc740 \uad6d\uc81c \ud504\ub85c\uc81d\ud2b8\uc5d0 \ucc38\uc5ec\ud558\uac70\ub098 \uae00\ub85c\ubc8c \uc6b4\uc601 \uc2dc\uc124\uc5d0 \uc7a5\ube44\ub97c \uc120\ud0dd\ud558\ub294 \uc804\uae30 \uc5d4\uc9c0\ub2c8\uc5b4, \ud328\ub110 \ube4c\ub354 \ubc0f \ud504\ub85c\uc81d\ud2b8 \uad00\ub9ac\uc790\uc5d0\uac8c \ud544\uc218\uc801\uc785\ub2c8\ub2e4. \uc774 \uac00\uc774\ub4dc\uc5d0\uc11c\ub294 \ub85c\ub4dc \uc13c\ud130\uc640 \ubc30\uc804\ubc18 \uac04\uc758 \uae30\uc220\uc801 \ubc0f \uaddc\uc81c\uc801 \ucc28\uc774\uc810\uc744 \uba85\ud655\ud788 \ud558\uc5ec \ud2b9\uc815 \uc694\uad6c \uc0ac\ud56d\uc5d0 \ub9de\ub294 \uc62c\ubc14\ub978 \uc7a5\ube44\ub97c \uc9c0\uc815\ud558\ub294 \ub370 \ub3c4\uc6c0\uc744 \ub4dc\ub9bd\ub2c8\ub2e4.<\/p>\n<h2>\uc6a9\uc5b4\uc758 \uc911\uc694\uc131 \u2013 \ub85c\ub4dc \uc13c\ud130 vs. \ubc30\uc804\ubc18<\/h2>\n<p>\u201c\ub85c\ub4dc \uc13c\ud130\u201d\uc640 \u201c\ubc30\uc804\ubc18\u201d\uc774\ub77c\ub294 \uc6a9\uc5b4\ub294 \uc885\uc885 \uc0c1\ud638 \uad50\ud658\uc801\uc73c\ub85c \uc0ac\uc6a9\ub418\uc9c0\ub9cc, \uc11c\ub85c \ub2e4\ub978 \ub300\ub959\uc5d0\uc11c \ubc1c\uc804\ud55c \ub69c\ub837\ud55c \uaddc\uc81c \uc804\ud1b5\uc744 \ubc18\uc601\ud569\ub2c8\ub2e4.<\/p>\n<p>A <strong>\ub85c\ub4dc \uc13c\ud130<\/strong> \ub294 \ub4e4\uc5b4\uc624\ub294 \uc804\ub825\uc744 \uac1c\ubcc4 \ubd84\uae30 \ud68c\ub85c\ub85c \ubd84\ubc30\ud558\ub294 \uc8fc\uac70\uc6a9 \ub610\ub294 \uacbd\uc0c1\uc5c5\uc6a9 \uc804\uae30 \ud328\ub110\uc5d0 \ub300\ud55c \ubd81\ubbf8 \uc6a9\uc5b4\uc785\ub2c8\ub2e4. \uc774 \uc6a9\uc5b4\ub294 NEMA \ud45c\uc900\uc5d0\uc11c \uc720\ub798\ud588\uc73c\uba70 UL 67(\ud328\ub110\ubcf4\ub4dc \ud45c\uc900) \ubc0f NEC(National Electrical Code)\uc5d0 \uae4a\uc774 \ubfcc\ub9ac\ub0b4\ub9ac\uace0 \uc788\uc2b5\ub2c8\ub2e4. \ub85c\ub4dc \uc13c\ud130\ub294 \uc77c\ubc18\uc801\uc73c\ub85c 120\/240V \ub2e8\uc0c1 \uc2dc\uc2a4\ud15c\uc5d0 \uc0ac\uc6a9\ub418\uba70 \uc54c\ub8e8\ubbf8\ub284 \ub610\ub294 \uad6c\ub9ac \ubc84\uc2a4 \ubc14\uc5d0 \uc7a5\ucc29\ub41c \ud50c\ub7ec\uadf8\uc778 \ud68c\ub85c \ucc28\ub2e8\uae30\ub97c \uc0ac\uc6a9\ud569\ub2c8\ub2e4.<\/p>\n<figure style=\"text-align: center; margin: 20px 0;\">\n        <img decoding=\"async\" src=\"https:\/\/img.viox.com\/Professional-installation-of-VIOX-NEMA-compliant-load-center-showing-organized-circuit-breakers-and-bus-bar-system.webp\" alt=\"Professional installation of VIOX NEMA compliant load center showing organized circuit breakers and bus bar system\" style=\"max-width: 100%; height: auto;\"><figcaption style=\"font-style: italic; color: #555; margin-top: 8px;\">\uadf8\ub9bc 1: \uccb4\uacc4\uc801\uc778 \ud68c\ub85c \ucc28\ub2e8\uae30\uc640 \uacac\uace0\ud55c \ubc84\uc2a4 \ubc14 \uc2dc\uc2a4\ud15c\uc744 \uac16\ucd98 VIOX NEMA \uc900\uc218 \ub85c\ub4dc \uc13c\ud130\uc758 \uc804\ubb38\uc801\uc778 \uc124\uce58 \ubaa8\uc2b5.<\/figcaption><\/figure>\n<p><strong>\ubc30\uc804\ubc18<\/strong> \ub294 \ub3d9\uc77c\ud55c \uae30\ub2a5 \uc7a5\ube44\uc5d0 \ub300\ud55c IEC \uc6a9\uc5b4\ub97c \ub098\ud0c0\ub0c5\ub2c8\ub2e4. \uc8fc\ub85c IEC 61439-3(\uc77c\ubc18\uc778\uc774 \uc791\ub3d9\ud558\ub3c4\ub85d \uc124\uacc4\ub41c \ubc30\uc804\ubc18)\uc758 \uc801\uc6a9\uc744 \ubc1b\uc73c\uba70, \uc774\ub7ec\ud55c \uc5b4\uc148\ube14\ub9ac\ub294 \ub3d9\uc77c\ud55c \ubaa9\uc801\uc744 \uc218\ud589\ud558\uc9c0\ub9cc \ub2e4\ub978 \uc124\uacc4 \uac80\uc99d \ubc29\ubc95\uacfc \uc131\ub2a5 \uae30\uc900\uc744 \ub530\ub985\ub2c8\ub2e4. IEC \ud504\ub808\uc784\uc6cc\ud06c\ub294 \uc18c\ube44\uc790 \uc7a5\uce58\uc640 \uc0b0\uc5c5\uc6a9 \uac1c\ud3d0 \uc7a5\uce58\ub97c \uad6c\ubcc4\ud558\uae30 \uc704\ud574 \u201cDBO\u201d(\uc77c\ubc18\uc778\uc6a9 \ubc30\uc804\ubc18) \uc57d\uc5b4\ub97c \uc0ac\uc6a9\ud569\ub2c8\ub2e4.<\/p>\n<p>\uc6a9\uc5b4 \ubd84\ud560\uc740 \ubcd1\ud589\uc801\uc778 \uaddc\uc81c \uac1c\ubc1c\uc5d0\uc11c \ube44\ub86f\ub418\uc5c8\uc2b5\ub2c8\ub2e4. NEMA\ub294 1926\ub144\uc5d0 \ubd81\ubbf8 \uc9c0\uc5ed\uc758 \uc804\uae30 \uc81c\uc870\ub97c \ud45c\uc900\ud654\ud558\uae30 \uc704\ud574 \uc124\ub9bd\ub418\uc5c8\uc73c\uba70, IEC\ub294 1906\ub144\uc5d0 \uc720\ub7fd \uc8fc\ub3c4\uc758 \uad6d\uc81c \ud45c\uc900 \uae30\uad6c\ub85c \ub4f1\uc7a5\ud588\uc2b5\ub2c8\ub2e4. \uc218\uc2ed \ub144 \ub3d9\uc548 \uc774\ub4e4 \uae30\uad00\uc740 \ub3c5\ub9bd\uc801\uc73c\ub85c \uc6b4\uc601\ub418\uba74\uc11c \uc624\ub298\ub0a0\uae4c\uc9c0 \uc9c0\uc18d\ub418\ub294 \ub69c\ub837\ud55c \uae30\uc220 \uc5b4\ud718\ub97c \ub9cc\ub4e4\uc5c8\uc2b5\ub2c8\ub2e4.<\/p>\n<p>\uae30\ub2a5\uc801\uc778 \uad00\uc810\uc5d0\uc11c \ubcfc \ub54c \ub450 \uc7a5\uce58\ub294 \ub4e4\uc5b4\uc624\ub294 \uc804\ub825\uc744 \uc218\uc2e0\ud558\uace0, \ubd84\uae30 \ud68c\ub85c\ub85c \ub098\ub204\uace0, \uac01 \ud68c\ub85c\uc5d0 \uacfc\uc804\ub958 \ubcf4\ud638\ub97c \uc81c\uacf5\ud558\ub294 \ub3d9\uc77c\ud55c \ud544\uc218 \uc791\uc5c5\uc744 \uc218\ud589\ud569\ub2c8\ub2e4. \uadf8\ub7ec\ub098 \uc124\uacc4, \ud14c\uc2a4\ud2b8 \ubc0f \uc124\uce58\ub97c \uaddc\uc81c\ud558\ub294 \uaddc\uc81c \ud504\ub808\uc784\uc6cc\ud06c\ub294 \ud06c\uac8c \ub2e4\ub985\ub2c8\ub2e4.<\/p>\n<h3>\ud45c 1: \ud45c\uc900 \uac04 \uc6a9\uc5b4 \ube44\uad50<\/h3>\n<table border=\"1\" style=\"border-collapse: collapse; width: 100%; text-align: left; margin-bottom: 20px;\">\n<thead>\n<tr style=\"background-color: #f2f2f2;\">\n<th style=\"padding: 8px;\">NEMA\/\ubd81\ubbf8<\/th>\n<th style=\"padding: 8px;\">IEC\/\uad6d\uc81c<\/th>\n<th style=\"padding: 8px;\">\uae30\ub2a5 \uc124\uba85<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"padding: 8px;\">\ub85c\ub4dc \uc13c\ud130<\/td>\n<td style=\"padding: 8px;\">\ubc30\uc804\ubc18(DBO)<\/td>\n<td style=\"padding: 8px;\">\uc8fc\uac70\uc6a9\/\uacbd\uc0c1\uc5c5\uc6a9 \ud328\ub110<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px;\">\ud328\ub110\ubcf4\ub4dc<\/td>\n<td style=\"padding: 8px;\">\ubc30\uc804\ubc18\/\uac1c\ud3d0\ubc18 \uc5b4\uc148\ube14\ub9ac<\/td>\n<td style=\"padding: 8px;\">\uc0c1\uc5c5\uc6a9\/\uc0b0\uc5c5\uc6a9 \ud328\ub110<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px;\">\uba54\uc778 \ucc28\ub2e8\uae30<\/td>\n<td style=\"padding: 8px;\">\uc8fc \ubcf4\ud638 \uc7a5\uce58<\/td>\n<td style=\"padding: 8px;\">1\ucc28 \uacfc\uc804\ub958 \ubcf4\ud638<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px;\">\ubd84\uae30 \ucc28\ub2e8\uae30<\/td>\n<td style=\"padding: 8px;\">\ucd9c\ub825 \ud68c\ub85c \ubcf4\ud638 \uc7a5\uce58<\/td>\n<td style=\"padding: 8px;\">\uac1c\ubcc4 \ud68c\ub85c \ubcf4\ud638<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px;\">\ubc84\uc2a4 \ubc14<\/td>\n<td style=\"padding: 8px;\">\ubc84\uc2a4\ubc14\/\uc8fc \ubc30\uc804 \ubc14<\/td>\n<td style=\"padding: 8px;\">\uc804\ub958 \ubd84\ubc30 \ub3c4\uccb4<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px;\">AIC \uc815\uaca9<\/td>\n<td style=\"padding: 8px;\">Icw\/Ipk \uc815\uaca9<\/td>\n<td style=\"padding: 8px;\">\ub2e8\ub77d \ub0b4\uc131 \uc6a9\ub7c9<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>NEMA \ud45c\uc900 \u2013 \ub85c\ub4dc \uc13c\ud130\uc5d0 \ub300\ud55c \ubd81\ubbf8 \uc811\uadfc \ubc29\uc2dd<\/h2>\n<p>NEMA(National Electrical Manufacturers Association)\ub294 \uc8fc\ub85c \ubbf8\uad6d, \uce90\ub098\ub2e4 \ubc0f \ub77c\ud2f4 \uc544\uba54\ub9ac\uce74 \uc77c\ubd80 \uc9c0\uc5ed\uc5d0\uc11c \uc0ac\uc6a9\ub418\ub294 \uc804\uae30 \uc7a5\ube44\uc5d0 \ub300\ud55c \ud3ec\uad04\uc801\uc778 \ud45c\uc900\uc744 \uc124\uc815\ud569\ub2c8\ub2e4. 1926\ub144\uc5d0 \uc124\ub9bd\ub41c NEMA\uc758 \uc811\uadfc \ubc29\uc2dd\uc740 \uacac\uace0\ud55c \uad6c\uc870, \ub0b4\uc7a5\ub41c \uc548\uc804 \uacc4\uc218 \ubc0f \uc26c\uc6b4 \uc120\ud0dd\uc744 \uac15\uc870\ud558\uba70, \uc774\ub294 \ud604\ub300\uc801\uc778 \ub85c\ub4dc \uc13c\ud130 \uc124\uacc4\uc758 \ud1a0\ub300\uac00 \ub418\uc5c8\uc2b5\ub2c8\ub2e4.<\/p>\n<h3>UL 67 \ubc0f NEMA PB1 \uc694\uad6c \uc0ac\ud56d<\/h3>\n<p>\ubd81\ubbf8 \uc2dc\uc7a5\uc6a9\uc73c\ub85c \uc81c\uc870\ub41c \ub85c\ub4dc \uc13c\ud130\ub294 \uac74\uc124, \uc131\ub2a5 \ubc0f \uc548\uc804 \uc694\uad6c \uc0ac\ud56d\uc744 \uc124\uc815\ud558\ub294 UL 67(\ud328\ub110\ubcf4\ub4dc)\uc744 \uc900\uc218\ud574\uc57c \ud569\ub2c8\ub2e4. NEMA \ud45c\uc900 PB1\uc740 600V \uc774\ud558\uc758 \uc800\uc804\uc555 \uac1c\ud3d0\ubc18 \ubc0f \ud328\ub110\ubcf4\ub4dc\uc5d0 \ub300\ud55c \ucd94\uac00 \uc9c0\uce68\uc73c\ub85c UL 67\uc744 \ubcf4\uc644\ud569\ub2c8\ub2e4.<\/p>\n<p>\uc774\ub7ec\ud55c \ud45c\uc900\uc740 \ub370\ub4dc \ud504\ub7f0\ud2b8 \uc124\uacc4(\ub3c4\uc5b4\uac00 \ub2eb\ud614\uc744 \ub54c \ub178\ucd9c\ub41c \ud65c\uc120 \ubd80\ud488 \uc5c6\uc74c), \uc8fc \uc811\uc9c0 \uc870\ud56d \ubc0f \uc628\ub3c4 \uc0c1\uc2b9 \uc81c\ud55c\uc744 \ud3ec\ud568\ud55c \ud2b9\uc815 \uac74\uc124 \uae30\ub2a5\uc744 \uc758\ubb34\ud654\ud569\ub2c8\ub2e4. UL 67\uc758 2017\ub144 \uac1c\uc815\ud310\uc5d0\ub294 \uc11c\ube44\uc2a4 \uc785\uad6c \uc694\uad6c \uc0ac\ud56d\uc774 \ucd94\uac00\ub418\uc5b4 \uc8fc \ucc28\ub2e8\uae30 \ud328\ub110\uc5d0\uc11c \ud65c\uc120 \ubd80\ud488\uacfc\uc758 \ubd80\uc8fc\uc758\ud55c \uc811\ucd09\uc744 \ubc29\uc9c0\ud558\ub294 \ubcf4\ud638 \uc7a5\ubcbd\uc744 \uc758\ubb34\ud654\ud588\uc2b5\ub2c8\ub2e4.<\/p>\n<h3>\uc77c\ubc18\uc801\uc778 NEMA \ub85c\ub4dc \uc13c\ud130 \uc0ac\uc591<\/h3>\n<p>NEMA \ub85c\ub4dc \uc13c\ud130\ub294 120\/240V \ub2e8\uc0c1 \uc8fc\uac70\uc6a9 \uc124\uce58\uc5d0\uc11c 480V 3\uc0c1 \uc0c1\uc5c5\uc6a9 \uc560\ud50c\ub9ac\ucf00\uc774\uc158\uc5d0 \uc774\ub974\ub294 \uc804\uc555 \uc2dc\uc2a4\ud15c\uc5d0 \uc0ac\uc6a9\ub429\ub2c8\ub2e4. \uc8fc\uac70\uc6a9 \ub85c\ub4dc \uc13c\ud130\ub294 \uc77c\ubc18\uc801\uc73c\ub85c 100A\uc5d0\uc11c 200A \uc8fc \ucc28\ub2e8\uae30 \uc815\uaca9 \ubc94\uc704\uc778 \ubc18\uba74, \uc0c1\uc5c5\uc6a9 \ud328\ub110\ubcf4\ub4dc\ub294 \uc801\uc808\ud55c \ud06c\uae30\uc758 \ubc84\uc2a4 \ubc14\ub97c \uc0ac\uc6a9\ud558\uc5ec \ucd5c\ub300 1200A\ub97c \ucc98\ub9ac\ud560 \uc218 \uc788\uc2b5\ub2c8\ub2e4.<\/p>\n<p>\ub2e8\ub77d \uc815\uaca9\uc740 AIC(Amperes Interrupting Capacity) \uba54\ud2b8\ub9ad\uc744 \uc0ac\uc6a9\ud558\uba70, \uc77c\ubc18\uc801\uc778 \uc8fc\uac70\uc6a9 \ub85c\ub4dc \uc13c\ud130\ub294 10,000 AIC \ub610\ub294 22,000 AIC\ub85c \uc815\uaca9\ub429\ub2c8\ub2e4. \uc0b0\uc5c5\uc6a9 \ud328\ub110\ubcf4\ub4dc\ub294 \uc720\ud2f8\ub9ac\ud2f0 \ubcc0\uc555\uae30 \ub610\ub294 \ub300\ud615 \ubc1c\uc804\uae30 \uadfc\ucc98\uc758 \uc124\uce58\uc5d0 \ub300\ud574 42,000 AIC \ub610\ub294 65,000 AIC \uc815\uaca9\uc774 \ud544\uc694\ud560 \uc218 \uc788\uc2b5\ub2c8\ub2e4.<\/p>\n<h3>\uc124\uacc4 \ucca0\ud559: \uacac\uace0\uc131 \ubc0f \uc548\uc804 \ub9c8\uc9c4<\/h3>\n<p>NEMA\uc758 \uc124\uacc4 \ucca0\ud559\uc740 \uc0c1\ub2f9\ud55c \uc548\uc804 \uacc4\uc218\ub97c \ud1b5\ud569\ud569\ub2c8\ub2e4. \ub85c\ub4dc \uc13c\ud130\ub294 \uc0c1\ub2f9\ud55c \uc5f4 \ud5e4\ub4dc\ub8f8\uc744 \uc720\uc9c0\ud558\uba74\uc11c \uc5f0\uc18d \ubd80\ud558\uc5d0\uc11c \uc548\uc815\uc801\uc73c\ub85c \uc791\ub3d9\ud558\ub3c4\ub85d \uc124\uacc4\ub418\uc5c8\uc2b5\ub2c8\ub2e4. \uc774 \uc811\uadfc \ubc29\uc2dd\uc740 \uacf5\uac04 \ud6a8\uc728\uc131 \ub610\ub294 \ucd08\uae30 \ube44\uc6a9\ubcf4\ub2e4 \uc7a5\uae30\uc801\uc778 \ub0b4\uad6c\uc131\uc744 \uc6b0\uc120\uc2dc\ud569\ub2c8\ub2e4.<\/p>\n<p>\ud68c\ub85c \ucc28\ub2e8\uae30\ub294 \ud50c\ub7ec\uadf8\uc628 \ub610\ub294 \ubcfc\ud2b8\uc628 \uc5f0\uacb0\uc744 \uc0ac\uc6a9\ud558\uc5ec \ubc84\uc2a4 \ubc14\uc5d0 \uc7a5\ucc29\ub429\ub2c8\ub2e4. \ud50c\ub7ec\uadf8\uc628 \ucc28\ub2e8\uae30\ub294 \ube60\ub978 \uc124\uce58 \ubc0f \uad50\uccb4\ub97c \uc81c\uacf5\ud558\uc5ec \uc8fc\uac70\uc6a9 \uc560\ud50c\ub9ac\ucf00\uc774\uc158\uc5d0\uc11c \ub110\ub9ac \uc0ac\uc6a9\ub429\ub2c8\ub2e4. \ubcfc\ud2b8\uc628 \ucc28\ub2e8\uae30\ub294 \uc9c4\ub3d9 \ub610\ub294 \ub192\uc740 \uace0\uc7a5 \uc804\ub958\uac00 \uc6b0\ub824\ub418\ub294 \uc0c1\uc5c5\uc6a9 \ubc0f \uc0b0\uc5c5\uc6a9 \uc124\uce58\uc5d0 \ub300\ud574 \ub354 \uc548\uc804\ud55c \uae30\uacc4\uc801 \ubc0f \uc804\uae30\uc801 \uc5f0\uacb0\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4.<\/p>\n<h3>NEMA \uc778\ud074\ub85c\uc800 \uc720\ud615<\/h3>\n<p>\ub85c\ub4dc \uc13c\ud130 \uc778\ud074\ub85c\uc800\ub294 \ud658\uacbd \uc870\uac74\uc5d0 \ub300\ud55c \ubcf4\ud638 \uc218\uc900\uc744 \uc815\uc758\ud558\ub294 NEMA 250 \ud45c\uc900\uc744 \ub530\ub985\ub2c8\ub2e4.<\/p>\n<ul>\n<li><strong>\uc720\ud615 1:<\/strong> \uc2e4\ub0b4 \uc0ac\uc6a9, \uba3c\uc9c0 \ubc0f \uc6b0\ubc1c\uc801\uc778 \uc811\ucd09\uc5d0 \ub300\ud55c \uc77c\ubc18\uc801\uc778 \ubcf4\ud638<\/li>\n<li><strong>368: \uc720\ud615 3R:<\/strong> \uc2e4\uc678 \uc0ac\uc6a9, \ubc30\uc218 \uc870\ud56d\uc774 \uc788\ub294 \ubc29\uc218<\/li>\n<li><strong>372: \uc720\ud615 4X:<\/strong> \uc2e4\ub0b4\/\uc2e4\uc678, \ub0b4\uc2dd\uc131(\uc77c\ubc18\uc801\uc73c\ub85c \uc2a4\ud14c\uc778\ub9ac\uc2a4 \uc2a4\ud2f8 \ub610\ub294 \uc720\ub9ac \uc12c\uc720), \ud638\uc2a4\uc5d0\uc11c \uc9c1\uc811 \ubd84\uc0ac\ub418\ub294 \ubb3c\uc5d0 \ub300\ud55c \ubcf4\ud638<\/li>\n<\/ul>\n<h3>\ud45c 2: \uc77c\ubc18\uc801\uc778 NEMA \ub85c\ub4dc \uc13c\ud130 \uc0ac\uc591<\/h3>\n<table border=\"1\" style=\"border-collapse: collapse; width: 100%; text-align: left; margin-bottom: 20px;\">\n<thead>\n<tr style=\"background-color: #f2f2f2;\">\n<th style=\"padding: 8px;\">\ub9e4\uac1c\ubcc0\uc218<\/th>\n<th style=\"padding: 8px;\">\uc8fc\uac70\uc6a9 \ubc94\uc704<\/th>\n<th style=\"padding: 8px;\">\uc0c1\uc5c5\uc6a9\/\uc0b0\uc5c5\uc6a9 \ubc94\uc704<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"padding: 8px;\">\uc804\uc555<\/td>\n<td style=\"padding: 8px;\">120\/240V 1\uc0c1<\/td>\n<td style=\"padding: 8px;\">208Y\/120V \ub610\ub294 480Y\/277V 3\uc0c1<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px;\">\uc8fc \ucc28\ub2e8\uae30 \uc815\uaca9<\/td>\n<td style=\"padding: 8px;\">100A \u2013 225A<\/td>\n<td style=\"padding: 8px;\">225A \u2013 1200A<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px;\">\ub2e8\ub77d \uc815\uaca9<\/td>\n<td style=\"padding: 8px;\">10kA \u2013 22kA AIC<\/td>\n<td style=\"padding: 8px;\">22kA \u2013 65kA AIC<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px;\">\ubc84\uc2a4 \uc7ac\ub8cc<\/td>\n<td style=\"padding: 8px;\">\uc54c\ub8e8\ubbf8\ub284(\uc8fc\uc11d \ub3c4\uae08) \ub610\ub294 \uad6c\ub9ac<\/td>\n<td style=\"padding: 8px;\">\uad6c\ub9ac(\uc740 \ub3c4\uae08)<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px;\">\ube0c\ub808\uc774\ucee4 \uc720\ud615<\/td>\n<td style=\"padding: 8px;\">\ud50c\ub7ec\uadf8\uc628<\/td>\n<td style=\"padding: 8px;\">\ud50c\ub7ec\uadf8\uc628 \ub610\ub294 \ubcfc\ud2b8\uc628<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px;\">\ud45c\uc900 \uc778\ud074\ub85c\uc800<\/td>\n<td style=\"padding: 8px;\">NEMA \uc720\ud615 1<\/td>\n<td style=\"padding: 8px;\">NEMA \uc720\ud615 1, 3R, 12<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px;\">\uad00\ub9ac \ud45c\uc900<\/td>\n<td style=\"padding: 8px;\">UL 67, NEMA PB1, NEC \uc870\ud56d 408<\/td>\n<td style=\"padding: 8px;\">UL 67, NEMA PB1, UL 891<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>IEC \ud45c\uc900 \u2013 \ubc30\uc804\ubc18\uc744 \uc704\ud55c \uae00\ub85c\ubc8c \ud504\ub808\uc784\uc6cc\ud06c<\/h2>\n<p>\uad6d\uc81c\uc804\uae30\uae30\uc220\uc704\uc6d0\ud68c(IEC)\ub294 \uc720\ub7fd, \uc544\uc2dc\uc544, \uc544\ud504\ub9ac\uce74, \uc911\ub3d9, \uadf8\ub9ac\uace0 \uc804 \uc138\uacc4\uc801\uc73c\ub85c \ub2e4\uad6d\uc801 \ud504\ub85c\uc81d\ud2b8\uc5d0\uc11c \uc0ac\uc6a9\ub418\ub294 \uc804\uae30 \uc7a5\ube44\uc5d0 \ub300\ud55c \uae30\uc220 \ud504\ub808\uc784\uc6cc\ud06c\ub97c \uc81c\uacf5\ud569\ub2c8\ub2e4. 1906\ub144\uc5d0 \uc124\ub9bd\ub41c IEC\uc758 \uc811\uadfc \ubc29\uc2dd\uc740 \uc815\uc758\ub41c \uc548\uc804 \ub9e4\uac1c\ubcc0\uc218 \ub0b4\uc5d0\uc11c \uc131\ub2a5 \uae30\ubc18 \uac80\uc99d \ubc0f \uc124\uacc4 \uc720\uc5f0\uc131\uc744 \uac15\uc870\ud569\ub2c8\ub2e4.<\/p>\n<h3>IEC 61439 \uc2dc\ub9ac\uc988: \uae30\ucd08<\/h3>\n<p>\ubc30\uc804\ubc18\uc740 2009\ub144\uc5d0 \uad6c\ud615 IEC 60439 \ud45c\uc900\uc744 \ub300\uccb4\ud55c IEC 61439 \uc2dc\ub9ac\uc988\uc5d0 \uc18d\ud569\ub2c8\ub2e4. \uc774 \ud3ec\uad04\uc801\uc778 \ud504\ub808\uc784\uc6cc\ud06c\ub294 \ub2e4\uc591\ud55c \uc870\ub9bd \uc720\ud615\uc744 \ub2e4\ub8e8\ub294 \uc5ec\ub7ec \ubd80\ubd84\uc73c\ub85c \uad6c\uc131\ub429\ub2c8\ub2e4.<\/p>\n<p>IEC 61439-1\uc740 \uc815\uc758, \uac80\uc99d \uc694\uad6c \uc0ac\ud56d \ubc0f \uad6c\uc131 \ud45c\uc900\uc744 \ud3ec\ud568\ud558\uc5ec \ubaa8\ub4e0 \uc800\uc804\uc555 \uac1c\ud3d0 \uc7a5\uce58 \ubc0f \uc81c\uc5b4 \uc7a5\uce58 \uc5b4\uc148\ube14\ub9ac\uc5d0 \uc801\uc6a9 \uac00\ub2a5\ud55c \uc77c\ubc18 \uaddc\uce59\uc744 \uc124\uc815\ud569\ub2c8\ub2e4. \uc774 \ubb38\uc11c\ub294 \uc815\uaca9 \uc804\ub958(\uc5b4\uc148\ube14\ub9ac\uc758 \uacbd\uc6b0 InA, \ud68c\ub85c\uc758 \uacbd\uc6b0 Inc), \uc815\uaca9 \uc804\uc555 \ubc0f \uc124\uacc4 \uac80\uc99d \uc808\ucc28\uc640 \uac19\uc740 \uae30\ubcf8 \uac1c\ub150\uc744 \uc815\uc758\ud569\ub2c8\ub2e4.<\/p>\n<p>IEC 61439-3\uc740 \ud2b9\ud788 \uc8fc\uac70\uc6a9 \uc18c\ube44\uc790 \uc7a5\uce58 \ubc0f \uacbd\uc0c1\uc5c5\uc6a9 \ubc30\uc804 \ud328\ub110\uc744 \ub2e4\ub8e8\ub294 \u201c\uc77c\ubc18\uc778\uc774 \uc791\ub3d9\ud558\ub3c4\ub85d \uc758\ub3c4\ub41c \ubc30\uc804\ubc18(DBO)\u201d\uc744 \ub2e4\ub8f9\ub2c8\ub2e4. \uc774 \ud45c\uc900\uc740 NEMA \ubd80\ud558 \uc13c\ud130\uc640 \uac00\uc7a5 \uc9c1\uc811\uc801\uc73c\ub85c \ube44\uad50\ud560 \uc218 \uc788\ub294 \uc7a5\ube44\ub97c \uc815\uc758\ud569\ub2c8\ub2e4.<\/p>\n<h3>IEC 61439-3\uc5d0 \ub530\ub978 \uc8fc\uc694 \uae30\uc220 \ub9e4\uac1c\ubcc0\uc218<\/h3>\n<p>IEC 61439-3\uc758 \uc801\uc6a9\uc744 \ubc1b\ub294 \ubc30\uc804\ubc18\uc5d0\ub294 \ud2b9\uc815 \uc791\ub3d9 \uc81c\ud55c\uc774 \uc788\uc2b5\ub2c8\ub2e4.<\/p>\n<ul>\n<li><strong>\uc811\uc9c0 \uacf5\uce6d \uc804\uc555:<\/strong> 300V AC \ucd08\uacfc \uae08\uc9c0 (IEC 61439-1:2020\uc758 \ud45c G.1\uc5d0 \ub530\ub984)<\/li>\n<li><strong>Inc (\ud68c\ub85c \uc815\uaca9 \uc804\ub958):<\/strong> \ucd9c\ub825 \ud68c\ub85c\uc758 \uacbd\uc6b0 125A \ucd08\uacfc \uae08\uc9c0<\/li>\n<li><strong>InA (\uc5b4\uc148\ube14\ub9ac \uc815\uaca9 \uc804\ub958):<\/strong> \uc804\uccb4 \uc5b4\uc148\ube14\ub9ac\uc758 \uacbd\uc6b0 250A \ucd08\uacfc \uae08\uc9c0<\/li>\n<li><strong>\ube48\ub3c4:<\/strong> \uc77c\ubc18\uc801\uc73c\ub85c 50Hz (60Hz \uc560\ud50c\ub9ac\ucf00\uc774\uc158\ub3c4 \ud3ec\ud568)<\/li>\n<\/ul>\n<p>\uc774\ub7ec\ud55c \ub9e4\uac1c\ubcc0\uc218\ub294 DBO\ub97c \uc804\ubb38\uc801\uc778 \uc804\uae30 \uad50\uc721 \uc5c6\uc774 \uc77c\ubc18\uc778(\uc8fc\ud0dd \uc18c\uc720\uc790, \uc0ac\ubb34\uc9c1 \uadfc\ub85c\uc790)\uc774 \uc2a4\uc704\uce58\ub97c \uc791\ub3d9\ud558\uac70\ub098 \ud4e8\uc988\ub97c \uad50\uccb4\ud560 \uc218 \uc788\ub294 \ube44\uc0b0\uc5c5\uc6a9 \uc560\ud50c\ub9ac\ucf00\uc774\uc158\uc6a9 \uc7a5\ube44\ub85c \uc815\uc758\ud569\ub2c8\ub2e4.<\/p>\n<figure style=\"text-align: center; margin: 20px 0;\">\n        <img decoding=\"async\" src=\"https:\/\/img.viox.com\/VIOX-IEC-61439-compliant-distribution-board-with-DIN-rail-mounted-circuit-breakers-and-IP54-protection-rating.webp\" alt=\"VIOX IEC 61439 compliant distribution board with DIN rail mounted circuit breakers and IP54 protection rating\" style=\"max-width: 100%; height: auto;\"><figcaption style=\"font-style: italic; color: #555; margin-top: 8px;\">\uadf8\ub9bc 2: DIN \ub808\uc77c \uc7a5\ucc29 \ud68c\ub85c \ucc28\ub2e8\uae30 \ubc0f \uc0b0\uc5c5 \uc548\uc804\uc744 \uc704\ud55c IP54 \ubcf4\ud638 \ub4f1\uae09\uc744 \ud2b9\uc9d5\uc73c\ub85c \ud558\ub294 VIOX IEC 61439 \uc900\uc218 \ubc30\uc804\ubc18.<\/figcaption><\/figure>\n<h3>\uc131\ub2a5 \uae30\ubc18 \uc124\uacc4 \uac80\uc99d<\/h3>\n<p>IEC 61439\ub294 NEMA\uc758 \uaddc\uc815\uc801 \uc694\uad6c \uc0ac\ud56d\uacfc \uadfc\ubcf8\uc801\uc73c\ub85c \ub2e4\ub978 \uc131\ub2a5 \uae30\ubc18 \uc811\uadfc \ubc29\uc2dd\uc744 \ub3c4\uc785\ud569\ub2c8\ub2e4. \uc81c\uc870\uc5c5\uccb4\ub294 \ub2e4\uc74c\uc744 \ud1b5\ud574 \uc124\uacc4\ub97c \uac80\uc99d\ud574\uc57c \ud569\ub2c8\ub2e4.<\/p>\n<ul>\n<li><strong>\uc720\ud615 \ud14c\uc2a4\ud2b8:<\/strong> \uc628\ub3c4 \uc0c1\uc2b9 \uac80\uc99d, \ub2e8\ub77d \ud14c\uc2a4\ud2b8, \uc720\uc804 \ud2b9\uc131 \ubc0f \uae30\uacc4\uc801 \uc791\ub3d9\uc744 \ud3ec\ud568\ud55c \ub300\ud45c\uc801\uc778 \uc5b4\uc148\ube14\ub9ac \uc124\uacc4\uc5d0 \ub300\ud55c \ud3ec\uad04\uc801\uc778 \ud14c\uc2a4\ud2b8. \uc77c\ub2e8 \ud615\uc2dd \ud14c\uc2a4\ud2b8\ub97c \uac70\uce58\uba74 \uc124\uacc4\ub294 \u201c\uac80\uc99d\ub41c \uc5b4\uc148\ube14\ub9ac\u201d\uac00 \ub429\ub2c8\ub2e4.\u201d<\/li>\n<li><strong>\uc815\uae30 \ud14c\uc2a4\ud2b8:<\/strong> \ubaa8\ub4e0 \uc81c\uc870 \uc7a5\uce58\ub294 \uc720\uc804\uccb4 \ud14c\uc2a4\ud2b8 \ubc0f \uc791\ub3d9 \uc810\uac80\uc744 \ud3ec\ud568\ud55c \uae30\ubcf8 \uac80\uc99d\uc744 \uac70\uce58\uc9c0\ub9cc \uc804\uccb4 \ud615\uc2dd \ud14c\uc2a4\ud2b8 \uc81c\ud488\uad70\uc740 \uac70\uce58\uc9c0 \uc54a\uc2b5\ub2c8\ub2e4.<\/li>\n<li><strong>\ube44\uad50\uc5d0 \uc758\ud55c \uc124\uacc4 \uac80\uc99d:<\/strong> \ud328\ub110 \ube4c\ub354\ub294 \uc2dc\uc2a4\ud15c \uc81c\uc870\uc5c5\uccb4\uc758 \uc0ac\uc591\uc744 \uc815\ud655\ud788 \ub530\ub974\ub294 \uacbd\uc6b0 \ud615\uc2dd \ud14c\uc2a4\ud2b8\ub97c \ubc18\ubcf5\ud558\uc9c0 \uc54a\uace0\ub3c4 \uc6d0\ub798 \uc81c\uc870\uc5c5\uccb4\uc758 \uac80\uc99d\ub41c \uc2dc\uc2a4\ud15c\uc744 \uc0ac\uc6a9\ud558\uc5ec \uc5b4\uc148\ube14\ub9ac\ub97c \uad6c\uc131\ud560 \uc218 \uc788\uc2b5\ub2c8\ub2e4.<\/li>\n<\/ul>\n<p>\uc774 \uc811\uadfc \ubc29\uc2dd\uc740 \uc5c4\uaca9\ud55c \ucd08\uae30 \uac80\uc99d\uc744 \ud1b5\ud574 \uc548\uc804\uc744 \uc720\uc9c0\ud558\uba74\uc11c \ub354 \ud070 \uc124\uacc4 \uc720\uc5f0\uc131\uc744 \ud5c8\uc6a9\ud569\ub2c8\ub2e4. \uadf8\ub7ec\ub098 \uc81c\uc870\uc5c5\uccb4\ub294 \uaddc\uc815 \uc900\uc218\ub97c \uc785\uc99d\ud558\ub294 \ubb38\uc11c\ub97c \uc720\uc9c0 \uad00\ub9ac\ud574\uc57c \ud558\ub294 \uc0c1\ub2f9\ud55c \ucc45\uc784\uc774 \uc788\uc2b5\ub2c8\ub2e4.<\/p>\n<h3>IP \ub4f1\uae09\uc774 NEMA \uc720\ud615\uc744 \ub300\uccb4\ud569\ub2c8\ub2e4.<\/h3>\n<p>NEMA \uc778\ud074\ub85c\uc800 \uc720\ud615 \ub300\uc2e0 IEC\ub294 IEC 60529\uc5d0 \uc815\uc758\ub41c IP(\uce68\ud22c \ubcf4\ud638) \ub4f1\uae09 \uc2dc\uc2a4\ud15c\uc744 \uc0ac\uc6a9\ud569\ub2c8\ub2e4. IP \ub4f1\uae09\uc740 \ub450 \uc790\ub9ac \uc22b\uc790\ub85c \uad6c\uc131\ub429\ub2c8\ub2e4. \uccab \ubc88\uc9f8 \uc22b\uc790\ub294 \uace0\uccb4 \uc785\uc790 \ubcf4\ud638\ub97c \ub098\ud0c0\ub0b4\uace0 \ub450 \ubc88\uc9f8 \uc22b\uc790\ub294 \uc561\uccb4 \uce68\ud22c \ubcf4\ud638\ub97c \ub098\ud0c0\ub0c5\ub2c8\ub2e4.<\/p>\n<p>\ubc30\uc804\ubc18\uc5d0 \ub300\ud55c \uc77c\ubc18\uc801\uc778 \ub4f1\uae09:<\/p>\n<ul>\n<li><strong>IP40:<\/strong> &gt;1mm\uc758 \uace0\uccb4 \ubb3c\uccb4\ub85c\ubd80\ud130 \ubcf4\ud638, \uc561\uccb4 \ubcf4\ud638 \uc5c6\uc74c(\uc2e4\ub0b4 \uc560\ud50c\ub9ac\ucf00\uc774\uc158)<\/li>\n<li><strong>IP54:<\/strong> \ubc29\uc9c4, \ubb3c \ud280\uae40\uc73c\ub85c\ubd80\ud130 \ubcf4\ud638(\uacbd\uacf5\uc5c5)<\/li>\n<li><strong>IP65:<\/strong> \ubc29\uc9c4, \ubb3c \ubd84\uc0ac\ub85c\ubd80\ud130 \ubcf4\ud638(\uc2e4\uc678 \ub610\ub294 \uc5f4\uc545\ud55c \ud658\uacbd)<\/li>\n<\/ul>\n<h3>\ud45c 3: IEC 61439 \ubc30\uc804\ubc18 \uc8fc\uc694 \ub9e4\uac1c\ubcc0\uc218<\/h3>\n<table border=\"1\" style=\"border-collapse: collapse; width: 100%; text-align: left; margin-bottom: 20px;\">\n<thead>\n<tr style=\"background-color: #f2f2f2;\">\n<th style=\"padding: 8px;\">\ub9e4\uac1c\ubcc0\uc218<\/th>\n<th style=\"padding: 8px;\">IEC 61439-3 (DBO) \uc0ac\uc591<\/th>\n<th style=\"padding: 8px;\">\ucc38\uace0<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"padding: 8px;\">\uc811\uc9c0 \uacf5\uce6d \uc804\uc555<\/td>\n<td style=\"padding: 8px;\">\u2264300V AC<\/td>\n<td style=\"padding: 8px;\">\uc8fc\uac70 \ubc0f \uc18c\uaddc\ubaa8 \uc0c1\uc5c5\uc6a9<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px;\">Inc (\ud68c\ub85c \uc815\uaca9 \uc804\ub958)<\/td>\n<td style=\"padding: 8px;\">\u2264125A<\/td>\n<td style=\"padding: 8px;\">\uac1c\ubcc4 \ucd9c\ub825 \ud68c\ub85c<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px;\">InA(\uc5b4\uc148\ube14\ub9ac \uc815\uaca9 \uc804\ub958)<\/td>\n<td style=\"padding: 8px;\">\u2264250A<\/td>\n<td style=\"padding: 8px;\">\uc8fc \uc720\uc785 \uacf5\uae09 \uc7a5\uce58<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px;\">\ube48\ub3c4<\/td>\n<td style=\"padding: 8px;\">\uc77c\ubc18\uc801\uc73c\ub85c 50Hz<\/td>\n<td style=\"padding: 8px;\">60Hz \uc560\ud50c\ub9ac\ucf00\uc774\uc158 \ud3ec\ud568<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px;\">IP \ub4f1\uae09<\/td>\n<td style=\"padding: 8px;\">IP2X \ucd5c\uc18c (\uc77c\ubc18\uc801\uc778 IP40-IP54)<\/td>\n<td style=\"padding: 8px;\">\uc2e4\uc678 \uc0ac\uc6a9\uc744 \uc704\ud55c \ub354 \ub192\uc740 \ub4f1\uae09<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px;\">\ubcf4\ud638 \uc7a5\uce58<\/td>\n<td style=\"padding: 8px;\">IEC 60898, 61008, 61009\uc5d0 \ub530\ub978 MCB, RCCB, RCBO<\/td>\n<td style=\"padding: 8px;\">\ud45c\uc900\ud654\ub41c \uad6c\uc131 \uc694\uc18c \uc778\ud130\ud398\uc774\uc2a4<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px;\">\uac80\uc99d \ubc29\ubc95<\/td>\n<td style=\"padding: 8px;\">\ud615\uc2dd \ud14c\uc2a4\ud2b8 + \uc77c\uc0c1 \ud14c\uc2a4\ud2b8<\/td>\n<td style=\"padding: 8px;\">\ub610\ub294 \ube44\uad50\uc5d0 \uc758\ud55c \uac80\uc99d<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px;\">\uad00\ub9ac \ud45c\uc900<\/td>\n<td style=\"padding: 8px;\">IEC 61439-1, IEC 61439-3<\/td>\n<td style=\"padding: 8px;\">\ud30c\ud2b8 1: \uc77c\ubc18 \uaddc\uce59, \ud30c\ud2b8 3: DBO \ud2b9\uc815<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>\uc8fc\uc694 \uae30\uc220\uc801 \ucc28\uc774\uc810: \uc790\uc138\ud55c \ube44\uad50<\/h2>\n<p>\ubd80\ud558 \uc13c\ud130\uc640 \ubc30\uc804\ubc18\uc740 \ub3d9\uc77c\ud55c \uae30\ub2a5\uc801 \ubaa9\uc801\uc744 \uc218\ud589\ud558\uc9c0\ub9cc \uae30\ubcf8 \ud45c\uc900\uc740 \uc0ac\uc591, \uc124\uce58 \ubc0f \uc791\ub3d9\uc5d0 \uc601\ud5a5\uc744 \ubbf8\uce58\ub294 \uc758\ubbf8 \uc788\ub294 \uae30\uc220\uc801 \ucc28\uc774\uc810\uc744 \ub9cc\ub4ed\ub2c8\ub2e4.<\/p>\n<h3>\ud45c\uc900 \uae30\uad00 \ubc0f \uc9c0\ub9ac\uc801 \ubcf4\uae09\ub960<\/h3>\n<p>NEMA \ud45c\uc900\uc740 \ubd81\ubbf8(\ubbf8\uad6d, \uce90\ub098\ub2e4, \uba55\uc2dc\ucf54 \uc77c\ubd80) \ubc0f \uc5ed\uc0ac\uc801\uc73c\ub85c \ubbf8\uad6d \uc804\uae30 \uc778\ud504\ub77c\uc640 \uc5f0\uacb0\ub41c \uad6d\uac00\uc5d0\uc11c \uc9c0\ubc30\uc801\uc785\ub2c8\ub2e4. IEC \ud45c\uc900\uc740 \uc720\ub7fd, \uc544\uc2dc\uc544, \uc544\ud504\ub9ac\uce74, \uc911\ub3d9 \ubc0f NEMA \uc9c0\uc5ed \uc678\ubd80\uc758 \ub77c\ud2f4 \uc544\uba54\ub9ac\uce74\ub97c \ud3ec\ud568\ud55c \ub300\ubd80\ubd84\uc758 \uae00\ub85c\ubc8c \uc124\uce58\ub97c \uad00\ub9ac\ud569\ub2c8\ub2e4.<\/p>\n<p>\uc774\ub7ec\ud55c \uc9c0\ub9ac\uc801 \ubd84\ud560\uc740 \uc2e4\uc9c8\uc801\uc778 \ubb38\uc81c\ub97c \uc57c\uae30\ud569\ub2c8\ub2e4. NEMA \ud45c\uc900\uc5d0 \ub530\ub77c \uc124\uacc4\ub41c \uc2dc\uc124\uc740 \uaddc\uc81c \uc2b9\uc778 \uc5c6\uc774\ub294 IEC \uc7a5\ube44\ub97c \uc27d\uac8c \uc218\uc6a9\ud560 \uc218 \uc5c6\uc73c\uba70 \uadf8 \ubc18\ub300\ub3c4 \ub9c8\ucc2c\uac00\uc9c0\uc785\ub2c8\ub2e4. \uc5ec\ub7ec \uad6d\uac00\uc5d0 \uac78\uccd0 \uc788\ub294 \ud504\ub85c\uc81d\ud2b8\ub294 \uc885\uc885 \ub450 \ud504\ub808\uc784\uc6cc\ud06c\ub97c \ubaa8\ub450 \uc218\uc6a9\ud558\uae30 \uc704\ud574 \ubcd1\ub82c \uc0ac\uc591\uc774 \ud544\uc694\ud569\ub2c8\ub2e4.<\/p>\n<h3>\uc804\uc555 \ubc0f \uc8fc\ud30c\uc218 \uace0\ub824 \uc0ac\ud56d<\/h3>\n<p>\ubd81\ubbf8 \uc2dc\uc2a4\ud15c\uc740 \uc77c\ubc18\uc801\uc73c\ub85c 120\/240V \ub2e8\uc0c1 \ub610\ub294 208Y\/120V \ubc0f 480Y\/277V 3\uc0c1 \uc804\uc555\uc73c\ub85c 60Hz\uc5d0\uc11c \uc791\ub3d9\ud569\ub2c8\ub2e4. IEC \uc9c0\uc5ed\uc740 \uc8fc\ub85c 230V \ub2e8\uc0c1(400V 3\uc0c1 Y \uc2dc\uc2a4\ud15c\uc5d0\uc11c \uc0c1-\uc911\uc131\uc120)\uc73c\ub85c 50Hz \uc2dc\uc2a4\ud15c\uc744 \uc0ac\uc6a9\ud569\ub2c8\ub2e4.<\/p>\n<p>\uc774\ub7ec\ud55c \uadfc\ubcf8\uc801\uc778 \ucc28\uc774\uc810\uc740 \ubc30\uc804\ubc18 \uc790\uccb4\ub97c \ub118\uc5b4 \uc5f0\uacb0\ub41c \ubd80\ud558, \ubaa8\ud130 \uc18d\ub3c4, \ubcc0\uc555\uae30 \uc120\ud0dd \ubc0f \uace0\uc870\ud30c \uace0\ub824 \uc0ac\ud56d\uc5d0 \uc601\ud5a5\uc744 \ubbf8\uce69\ub2c8\ub2e4. \uc2dc\uc2a4\ud15c \uc8fc\ud30c\uc218\ub97c \ud574\uacb0\ud558\uc9c0 \uc54a\uace0 \ubc30\uc804\ubc18\uc744 \ub2e8\uc21c\ud788 \ub300\uccb4\ud558\uba74 \uc791\ub3d9 \ubb38\uc81c\uac00 \ubc1c\uc0dd\ud569\ub2c8\ub2e4.<\/p>\n<h3>\uc804\ub958 \uc815\uaca9 \ucca0\ud559<\/h3>\n<p>NEMA \ubd80\ud558 \uc13c\ud130\ub294 \uc0c1\ub2f9\ud55c \uc5f4\uc801 \ub9c8\uc9c4\uc73c\ub85c \uc815\uaca9 \uc804\ub958\uc758 100%\uc5d0\uc11c \uc9c0\uc18d\uc801\uc73c\ub85c \uc791\ub3d9\ud560 \uc218 \uc788\ub294 \uc11c\ube44\uc2a4 \uacc4\uc218\ub97c \ud1b5\ud569\ud569\ub2c8\ub2e4. \uc774 \ubcf4\uc218\uc801\uc778 \uc811\uadfc \ubc29\uc2dd\uc740 200A \ubd80\ud558 \uc13c\ud130\uac00 \ub514\ub808\uc774\ud305 \uc5c6\uc774 200A\ub97c \uc548\uc815\uc801\uc73c\ub85c \uc9c0\uc18d\uc801\uc73c\ub85c \ucc98\ub9ac\ud560 \uc218 \uc788\uc74c\uc744 \uc758\ubbf8\ud569\ub2c8\ub2e4.<\/p>\n<p>IEC \ubc30\uc804\ubc18\uc740 \ud2b9\uc815 \uc560\ud50c\ub9ac\ucf00\uc774\uc158\uc5d0 \uc7a5\uce58\ub97c \uc77c\uce58\uc2dc\ud0a4\uae30 \uc704\ud574 \ud65c\uc6a9 \ubc94\uc8fc\ub97c \uc0ac\uc6a9\ud558\uc5ec \ud14c\uc2a4\ud2b8\ub41c \uc6a9\ub7c9\uc5d0 \ub530\ub77c \uad6c\uc131 \uc694\uc18c\ub97c \ub354 \uc815\ud655\ud558\uac8c \ud3c9\uac00\ud569\ub2c8\ub2e4. 250A InA\ub85c \uc815\uaca9\ub41c DBO\ub294 \uc815\uc758\ub41c \uc870\uac74\uc5d0\uc11c \ud574\ub2f9 \uc218\uc900\uc5d0\uc11c \uc791\ub3d9\ud558\uba70, \uc720\uc0ac\ud55c NEMA \uc7a5\ube44\ubcf4\ub2e4 \ub0b4\uc7ac\ub41c \uc624\ubc84\ud5e4\ub4dc\uac00 \uc801\uc2b5\ub2c8\ub2e4.<\/p>\n<h3>\ub2e8\ub77d \ud68c\ub85c \uc131\ub2a5 \uc9c0\ud45c<\/h3>\n<p>NEMA\ub294 AIC(\ucc28\ub2e8 \uc6a9\ub7c9) \ub4f1\uae09\uc744 \uc0ac\uc6a9\ud558\uba70, \uc77c\ubc18\uc801\uc73c\ub85c \ubd80\ud558 \uc13c\ud130\uc758 \uacbd\uc6b0 10kA, 22kA, 42kA \ub610\ub294 65kA\uc785\ub2c8\ub2e4. \uc774 \ub2e8\uc77c \uc22b\uc790\ub294 \uc5b4\uc148\ube14\ub9ac\uac00 \uc548\uc804\ud558\uac8c \ucc28\ub2e8\ud558\uace0 \uc81c\uac70\ud560 \uc218 \uc788\ub294 \ucd5c\ub300 \uace0\uc7a5 \uc804\ub958\ub97c \ub098\ud0c0\ub0c5\ub2c8\ub2e4.<\/p>\n<p>IEC\ub294 \uc5ec\ub7ec \ub2e8\ub77d \ud68c\ub85c \ub9e4\uac1c\ubcc0\uc218\ub97c \uc0ac\uc6a9\ud569\ub2c8\ub2e4.<\/p>\n<ul>\n<li><strong>Icw(\uc815\uaca9 \ub2e8\uc2dc\uac04 \ub0b4\uc804\ub958):<\/strong> \uc5b4\uc148\ube14\ub9ac\uac00 \uc9c0\uc815\ub41c \uc2dc\uac04(\uc77c\ubc18\uc801\uc73c\ub85c 1\ucd08) \ub3d9\uc548 \uacac\ub51c \uc218 \uc788\ub294 \uc804\ub958 \ub808\ubca8<\/li>\n<li><strong>Ipk(\uc815\uaca9 \ud53c\ud06c \ub0b4\uc804\ub958):<\/strong> \uace0\uc7a5 \uc2dc \ucd5c\ub300 \uc21c\uac04 \ud53c\ud06c \uc804\ub958<\/li>\n<li><strong>Icc(\uc870\uac74\ubd80 \ub2e8\ub77d \ud68c\ub85c \uc804\ub958):<\/strong> \ud2b9\uc815 \uc0c1\uc704 \uc7a5\uce58\uc640 \uc870\uc815\ub41c \ub2e8\ub77d \ud68c\ub85c \ubcf4\ud638<\/li>\n<\/ul>\n<p>\uc774 \ub2e4\uc911 \ub9e4\uac1c\ubcc0\uc218 \uc811\uadfc \ubc29\uc2dd\uc740 \ub354 \uc790\uc138\ud55c \uace0\uc7a5 \uc131\ub2a5 \uc815\ubcf4\ub97c \uc81c\uacf5\ud558\uc9c0\ub9cc \uc0ac\uc591 \uc791\uc131 \uc2dc \ub354 \uc815\uad50\ud55c \ubd84\uc11d\uc774 \ud544\uc694\ud569\ub2c8\ub2e4.<\/p>\n<figure style=\"text-align: center; margin: 20px 0;\">\n        <img decoding=\"async\" src=\"https:\/\/img.viox.com\/Technical-comparison-diagram-showing-NEMA-AIC-ratings-versus-IEC-Icw-and-Ipk-short-circuit-parameters.webp\" alt=\"Technical comparison diagram showing NEMA AIC ratings versus IEC Icw and Ipk short circuit parameters\" style=\"max-width: 100%; height: auto;\"><figcaption style=\"font-style: italic; color: #555; margin-top: 8px;\">\uadf8\ub9bc 3: NEMA AIC \ub4f1\uae09\uacfc IEC Icw\/Ipk \ub2e8\ub77d \ud68c\ub85c \ub9e4\uac1c\ubcc0\uc218 \uac04\uc758 \ucc28\uc774\uc810\uc744 \ubcf4\uc5ec\uc8fc\ub294 \uae30\uc220 \ube44\uad50 \ub2e4\uc774\uc5b4\uadf8\ub7a8.<\/figcaption><\/figure>\n<h3>\uc778\ud074\ub85c\uc800 \ubcf4\ud638 \ucca0\ud559<\/h3>\n<p>NEMA \uc720\ud615 \ub4f1\uae09(1, 3R, 4X, 12)\uc740 \uad11\ubc94\uc704\ud55c \ubc94\uc8fc\ub97c \ud1b5\ud574 \ud658\uacbd \uc704\ud5d8\uc5d0 \ub300\ud55c \uc644\uc804\ud55c \uc778\ud074\ub85c\uc800 \uc131\ub2a5\uc744 \uc124\uba85\ud569\ub2c8\ub2e4. \u201cNEMA 3R\u201d\uc744 \uc9c0\uc815\ud558\ub294 \uc5d4\uc9c0\ub2c8\uc5b4\ub294 \uc790\uc138\ud55c \ubd84\uc11d \uc5c6\uc774\ub3c4 \uc778\ud074\ub85c\uc800\uac00 \uc2e4\uc678 \ube57\ubb3c \ubcf4\ud638 \uae30\ub2a5\uc744 \uc81c\uacf5\ud55c\ub2e4\ub294 \uac83\uc744 \uc54c\uace0 \uc788\uc2b5\ub2c8\ub2e4.<\/p>\n<p>IEC IP \ub4f1\uae09\uc740 \ub354 \uc138\ubd84\ud654\ub41c \uc0ac\uc591\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4. IP54 \uc778\ud074\ub85c\uc800\ub294 \uba3c\uc9c0 \ubcf4\ud638(5) \ubc0f \ud280\ub294 \ubb3c \ubcf4\ud638(4)\ub97c \uc81c\uacf5\ud558\uc5ec \ud658\uacbd \uc870\uac74\uc5d0 \uc815\ud655\ud558\uac8c \ub9de\ucd9c \uc218 \uc788\uc2b5\ub2c8\ub2e4. \uadf8\ub7ec\ub098 IP \ub4f1\uae09\uc740 NEMA \uc720\ud615\uc5d0\uc11c \ub2e4\ub8e8\ub294 \ubd80\uc2dd \ubc29\uc9c0, \ucda9\uaca9 \ubcf4\ud638 \ub610\ub294 \uae30\ud0c0 \uc694\uc18c\ub97c \ub2e4\ub8e8\uc9c0 \uc54a\uc73c\ubbc0\ub85c \ucd94\uac00 \uc0ac\uc591\uc774 \ud544\uc694\ud560 \uc218 \uc788\uc2b5\ub2c8\ub2e4.<\/p>\n<h3>\uac80\uc99d \ubc0f \uc900\uc218 \uc811\uadfc \ubc29\uc2dd<\/h3>\n<p>NEMA\ub294 \uaddc\uc815\uc801 \uc811\uadfc \ubc29\uc2dd\uc744 \ub530\ub985\ub2c8\ub2e4. \ud45c\uc900\uc740 \uc81c\uc870\uc5c5\uccb4\uac00 \ub530\ub77c\uc57c \ud558\ub294 \ud2b9\uc815 \uad6c\uc131 \uc694\uad6c \uc0ac\ud56d, \uc7ac\ub8cc \ubc0f \ud14c\uc2a4\ud2b8 \uc808\ucc28\ub97c \uc815\uc758\ud569\ub2c8\ub2e4. \uc900\uc218\ub294 \uc815\uc758\ub41c \uae30\uc900\uc744 \ucda9\uc871\ud558\ub294 \uac83\uc744 \uc758\ubbf8\ud569\ub2c8\ub2e4.<\/p>\n<p>IEC\ub294 \uc131\ub2a5 \uae30\ubc18 \uac80\uc99d\uc744 \uc0ac\uc6a9\ud569\ub2c8\ub2e4. \ud45c\uc900\uc740 \ud544\uc694\ud55c \uc131\ub2a5 \uc218\uc900\uc744 \uc815\uc758\ud558\uc9c0\ub9cc \uc81c\uc870\uc5c5\uccb4\ub294 \uc774\ub97c \ub2ec\uc131\ud558\ub294 \ub370 \uc720\uc5f0\uc131\uc744 \uac00\uc9c8 \uc218 \uc788\uc2b5\ub2c8\ub2e4. \ud615\uc2dd \ud14c\uc2a4\ud2b8\ub294 \uc124\uacc4 \uc801\uc808\uc131\uc744 \uc785\uc99d\ud569\ub2c8\ub2e4. \uc9c0\uc18d\uc801\uc778 \uc77c\uc0c1 \ud14c\uc2a4\ud2b8\ub294 \uc77c\uad00\uc131\uc744 \ubcf4\uc7a5\ud569\ub2c8\ub2e4. \uc774 \uc811\uadfc \ubc29\uc2dd\uc740 \ud601\uc2e0\uc744 \uc7a5\ub824\ud558\uc9c0\ub9cc \uc5c4\uaca9\ud55c \ubb38\uc11c\ud654\uac00 \ud544\uc694\ud569\ub2c8\ub2e4.<\/p>\n<h3>\ud45c 4: NEMA \ubd80\ud558 \uc13c\ud130 \ub300 IEC \ubc30\uc804\ubc18 \u2013 \uae30\uc220 \ube44\uad50 \ub9e4\ud2b8\ub9ad\uc2a4<\/h3>\n<table border=\"1\" style=\"border-collapse: collapse; width: 100%; text-align: left; margin-bottom: 20px;\">\n<thead>\n<tr style=\"background-color: #f2f2f2;\">\n<th style=\"padding: 8px;\">\uce21\uba74<\/th>\n<th style=\"padding: 8px;\">NEMA \ubd80\ud558 \uc13c\ud130<\/th>\n<th style=\"padding: 8px;\">IEC \ubc30\uc804\ubc18<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"padding: 8px;\"><strong>\uae30\ubcf8 \ud45c\uc900<\/strong><\/td>\n<td style=\"padding: 8px;\">UL 67, NEMA PB1<\/td>\n<td style=\"padding: 8px;\">IEC 61439-1, IEC 61439-3<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px;\"><strong>\uc9c0\ub9ac\uc801 \uc0ac\uc6a9<\/strong><\/td>\n<td style=\"padding: 8px;\">\ubd81\ubbf8, \ub77c\ud2f4 \uc544\uba54\ub9ac\uce74 \uc77c\ubd80<\/td>\n<td style=\"padding: 8px;\">\uc720\ub7fd, \uc544\uc2dc\uc544, \uc544\ud504\ub9ac\uce74, \uc911\ub3d9, \uc804 \uc138\uacc4<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px;\"><strong>\uc77c\ubc18 \uc804\uc555<\/strong><\/td>\n<td style=\"padding: 8px;\">120\/240V(1\u03c6), 208Y\/120V, 480Y\/277V(3\u03c6)<\/td>\n<td style=\"padding: 8px;\">230V(1\u03c6), 400Y\/230V(3\u03c6)<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px;\"><strong>\ube48\ub3c4<\/strong><\/td>\n<td style=\"padding: 8px;\">60Hz<\/td>\n<td style=\"padding: 8px;\">50Hz(60Hz \ud3ec\ud568)<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px;\"><strong>\uc8fc\uac70\uc6a9 \uc804\ub958 \ubc94\uc704<\/strong><\/td>\n<td style=\"padding: 8px;\">100A \u2013 200A<\/td>\n<td style=\"padding: 8px;\">InA \ucd5c\ub300 250A, Inc \ucd5c\ub300 125A<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px;\"><strong>\ub2e8\ub77d \uc815\uaca9<\/strong><\/td>\n<td style=\"padding: 8px;\">AIC(10kA, 22kA, 42kA, 65kA)<\/td>\n<td style=\"padding: 8px;\">Icw\/Ipk(\uc9c0\uc815\ub41c \uc2dc\uac04 \ub3d9\uc548 kA)<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px;\"><strong>\uc778\ud074\ub85c\uc800 \ubcf4\ud638<\/strong><\/td>\n<td style=\"padding: 8px;\">NEMA \uc720\ud615 1, 3R, 4X, 12<\/td>\n<td style=\"padding: 8px;\">IP \ub4f1\uae09(IP40, IP54, IP65)<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px;\"><strong>\uc124\uacc4 \ucca0\ud559<\/strong><\/td>\n<td style=\"padding: 8px;\">\uaddc\uc815\uc801, \uc548\uc804 \uacc4\uc218 \ub0b4\uc7a5<\/td>\n<td style=\"padding: 8px;\">\uc131\ub2a5 \uae30\ubc18, \uc124\uacc4 \uac80\uc99d<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px;\"><strong>\ucc28\ub2e8\uae30 \uc7a5\ucc29<\/strong><\/td>\n<td style=\"padding: 8px;\">\ubc84\uc2a4\uc5d0 \ud50c\ub7ec\uadf8\uc628 \ub610\ub294 \ubcfc\ud2b8\uc628<\/td>\n<td style=\"padding: 8px;\">DIN \ub808\uc77c, \ubcfc\ud2b8\uc628 \ub610\ub294 \ud50c\ub7ec\uadf8\uc778 \ubaa8\ub4c8\uc2dd<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px;\"><strong>\uac80\uc99d \ubc29\ubc95<\/strong><\/td>\n<td style=\"padding: 8px;\">UL 67\uc5d0 \ub530\ub978 \uc900\uc218 \ud14c\uc2a4\ud2b8<\/td>\n<td style=\"padding: 8px;\">\ud615\uc2dd \ud14c\uc2a4\ud2b8 + \uc77c\uc0c1 \ud14c\uc2a4\ud2b8<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px;\"><strong>\uad6c\uc131 \uc694\uc18c \uc120\ud0dd<\/strong><\/td>\n<td style=\"padding: 8px;\">\ubcf4\uc218\uc801\uc778 \ud06c\uae30 \uc870\uc815, \ub354 \ub192\uc740 \uc11c\ube44\uc2a4 \uacc4\uc218<\/td>\n<td style=\"padding: 8px;\">\ud65c\uc6a9 \ubc94\uc8fc\ub97c \ud1b5\ud55c \uc815\ud655\ud55c \ub9e4\uce6d<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px;\"><strong>\uc77c\ubc18\uc801\uc778 \ubc84\uc2a4 \uc7ac\ub8cc<\/strong><\/td>\n<td style=\"padding: 8px;\">\uc54c\ub8e8\ubbf8\ub284(\uc8fc\uc11d \ub3c4\uae08) \ub610\ub294 \uad6c\ub9ac<\/td>\n<td style=\"padding: 8px;\">\uc801\uc808\ud55c \ub3c4\uae08\uc774 \ub41c \uc54c\ub8e8\ubbf8\ub284 \ub610\ub294 \uad6c\ub9ac<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>\uc5d4\uc9c0\ub2c8\uc5b4 \ubc0f \uc0ac\uc591 \uc791\uc131\uc790\ub97c \uc704\ud55c \uc2e4\uc81c\uc801 \uc758\ubbf8<\/h2>\n<p>NEMA\uc640 IEC \ud45c\uc900 \uac04\uc758 \uae30\uc220\uc801 \ucc28\uc774\uc810\uc744 \uc774\ud574\ud558\uba74 \ud504\ub85c\uc81d\ud2b8 \uc131\uacf5, \ube44\uc6a9 \ubc0f \uc7a5\uae30 \uc6b4\uc601\uc5d0 \uc601\ud5a5\uc744 \ubbf8\uce58\ub294 \uc2e4\uc81c \uc0ac\uc591 \uacb0\uc815\uc73c\ub85c \uc774\uc5b4\uc9d1\ub2c8\ub2e4.<\/p>\n<h3>\uc9c0\ub9ac\uc801 \uc704\uce58\uac00 \uae30\ubcf8 \ud45c\uc900\uc744 \uc8fc\ub3c4\ud569\ub2c8\ub2e4.<\/h3>\n<p>\ud504\ub85c\uc81d\ud2b8 \uc704\uce58\ub294 \ud45c\uc900 \uc120\ud0dd\uc5d0 \uc788\uc5b4 \uc9c0\ubc30\uc801\uc778 \uc694\uc18c\ub85c \ub0a8\uc544 \uc788\uc2b5\ub2c8\ub2e4. \ubd81\ubbf8 \ud504\ub85c\uc81d\ud2b8\uc5d0\uc11c\ub294 \ud604\uc9c0 \uc804\uae30 \uaddc\uc815 \ubc0f \uac80\uc0ac \uc694\uad6c \uc0ac\ud56d\uc744 \ucda9\uc871\ud558\uae30 \uc704\ud574 NEMA \uc900\uc218 \ubd80\ud558 \uc13c\ud130\uac00 \ud544\uc694\ud569\ub2c8\ub2e4. IEC \uc9c0\uc5ed\uc758 \ud504\ub85c\uc81d\ud2b8\uc5d0\uc11c\ub294 \uaddc\uc81c \uc2b9\uc778\uc744 \uc5bb\uae30 \uc704\ud574 IEC 61439\ub97c \ucda9\uc871\ud558\ub294 \ubc30\uc804\ubc18\uc744 \uc9c0\uc815\ud574\uc57c \ud569\ub2c8\ub2e4.<\/p>\n<p>\uad6d\uc81c \ud504\ub85c\uc81d\ud2b8\ub294 \uc0ac\uc591 \ubb38\uc81c\ub97c \uc81c\uc2dc\ud569\ub2c8\ub2e4. \ubbf8\uad6d, \ub3c5\uc77c \ubc0f \uc911\uad6d\uc5d0 \ub3d9\uc77c\ud55c \uc2dc\uc124\uc744 \uac74\uc124\ud558\ub294 \uae00\ub85c\ubc8c \uc81c\uc870 \ud68c\uc0ac\ub294 \ubcd1\ub82c \uc0ac\uc591\uc774 \ud544\uc694\ud569\ub2c8\ub2e4. \ubbf8\uad6d \uc2dc\uc124\uc758 \uacbd\uc6b0 NEMA \ubd80\ud558 \uc13c\ud130, \ub3c5\uc77c \ubc0f \uc911\uad6d\uc758 \uacbd\uc6b0 IEC \ubc30\uc804\ubc18. \uc774 \uc911\ubcf5\uc740 \uc5d4\uc9c0\ub2c8\uc5b4\ub9c1 \ub178\ub825\uc744 \uc99d\uac00\uc2dc\ud0a4\uc9c0\ub9cc \ud604\uc9c0 \uc900\uc218\ub97c \ubcf4\uc7a5\ud569\ub2c8\ub2e4.<\/p>\n<h3>\uc9c1\uc811\uc801\uc778 \uc0c1\ud638 \uad50\ud658\uc131 \uc81c\ud55c<\/h3>\n<p>NEMA \ubd80\ud558 \uc13c\ud130\uc640 IEC \ubc30\uc804\ubc18\uc740 \uc804\uc555 \ubc0f \uc804\ub958 \ub4f1\uae09\uc774 \uc720\uc0ac\ud574 \ubcf4\uc774\ub294 \uacbd\uc6b0\uc5d0\ub3c4 \uc9c1\uc811\uc801\uc73c\ub85c \uc0c1\ud638 \uad50\ud658\ud560 \uc218 \uc5c6\uc2b5\ub2c8\ub2e4. NEMA \ubc84\uc2a4 \uc2dc\uc2a4\ud15c\uc6a9\uc73c\ub85c \uc124\uacc4\ub41c \ud68c\ub85c \ucc28\ub2e8\uae30\ub294 IEC DIN \ub808\uc77c \uc7a5\ucc29\uc5d0 \uae30\uacc4\uc801\uc73c\ub85c \ub9de\uc9c0 \uc54a\uc2b5\ub2c8\ub2e4. \ud544\uc694\ud55c \uac80\uc99d \ubb38\uc11c\ub294 \ud45c\uc900 \uac04\uc5d0 \uadfc\ubcf8\uc801\uc73c\ub85c \ub2e4\ub985\ub2c8\ub2e4.<\/p>\n<p>\ud55c \ud45c\uc900\uc744 \ub2e4\ub978 \ud45c\uc900\uc73c\ub85c \ub300\uccb4\ud558\ub824\ub294 \uc2dc\ub3c4\ub294 \uae30\uacc4\uc801 \ube44\ud638\ud658\uc131, \uaddc\uc815 \ubbf8\uc900\uc218, \ubcf4\uc99d \ubb34\ud6a8\ud654 \ubc0f \uc7a0\uc7ac\uc801\uc778 \uc548\uc804 \ubb38\uc81c\uc640 \uac19\uc740 \uc5ec\ub7ec \ubb38\uc81c\ub97c \uc57c\uae30\ud569\ub2c8\ub2e4. \uc7a5\ube44\ub294 \ud504\ub85c\uc81d\ud2b8 \ubb38\uc11c\uc5d0 \uc9c0\uc815\ub41c \ud45c\uc900\uacfc \uad00\ud560 \ub2f9\uad6d\uc5d0\uc11c \uc694\uad6c\ud558\ub294 \ud45c\uc900\uacfc \uc77c\uce58\ud574\uc57c \ud569\ub2c8\ub2e4.<\/p>\n<figure style=\"text-align: center; margin: 20px 0;\">\n        <img decoding=\"async\" src=\"https:\/\/img.viox.com\/Cutaway-technical-illustration-comparing-NEMA-plug-on-breaker-mounting-versus-IEC-DIN-rail-mounting-systems.webp\" alt=\"Cutaway technical illustration comparing NEMA plug on breaker mounting versus IEC DIN rail mounting systems\" style=\"max-width: 100%; height: auto;\"><figcaption style=\"font-style: italic; color: #555; margin-top: 8px;\">\uadf8\ub9bc 4: NEMA \ud50c\ub7ec\uadf8\uc628 \ucc28\ub2e8\uae30 \uc7a5\ucc29 \ub300 IEC DIN \ub808\uc77c \uc7a5\ucc29 \uc2dc\uc2a4\ud15c\uc758 \uc5ed\ud559\uc744 \ube44\uad50\ud558\ub294 \uae30\uc220 \ub2e8\uba74 \uadf8\ub9bc.<\/figcaption><\/figure>\n<h3>NEMA \ubd80\ud558 \uc13c\ud130\ub97c \uc9c0\uc815\ud574\uc57c \ud558\ub294 \uacbd\uc6b0<\/h3>\n<p>NEMA \uc7a5\ube44\ub294 \ub2e4\uc74c\uacfc \uac19\uc740 \ud2b9\uc9d5\uc744 \uac00\uc9c4 \ud504\ub85c\uc81d\ud2b8\uc5d0 \uc801\ud569\ud569\ub2c8\ub2e4.<\/p>\n<ul>\n<li><strong>\uc704\uce58:<\/strong> \ubbf8\uad6d, \uce90\ub098\ub2e4 \ub610\ub294 \uae30\ud0c0 NEMA \uc6b0\uc138 \uc9c0\uc5ed<\/li>\n<li><strong>\ud658\uacbd:<\/strong> \uacac\uace0\ud55c \uad6c\uc870\uac00 \uc7a5\uae30\uc801\uc778 \uc2e0\ub8b0\uc131\uc744 \uc81c\uacf5\ud558\ub294 \uc5f4\uc545\ud55c \uc0b0\uc5c5 \uc870\uac74<\/li>\n<li><strong>\uac04\ub2e8:<\/strong> \uac04\ub2e8\ud55c \uc120\ud0dd(\uc804\uc555 + \uc804\ub958 = \ubaa8\ub378 \ubc88\ud638)\uc73c\ub85c \uc0ac\uc591\uc744 \ube60\ub974\uac8c \ucc98\ub9ac\ud560 \uc218 \uc788\ub294 \uc560\ud50c\ub9ac\ucf00\uc774\uc158<\/li>\n<li><strong>\uac00\uc6a9\uc131:<\/strong> NEMA \uc7a5\ube44\ub97c \uc9e7\uc740 \ub9ac\ub4dc \ud0c0\uc784\uc73c\ub85c \uc27d\uac8c \uad6c\ud560 \uc218 \uc788\ub294 \uc9c0\uc5ed<\/li>\n<li><strong>\uc11c\ube44\uc2a4:<\/strong> NEMA \uc2dc\uc2a4\ud15c\uc5d0 \ub300\ud55c \uc720\uc9c0 \ubcf4\uc218 \ub2f4\ub2f9\uc790 \uad50\uc721 \uc2dc\uc124<\/li>\n<\/ul>\n<h3>IEC \ubc30\uc804\ubc18 \uc0ac\uc591 \uacb0\uc815 \uc2dc\uae30<\/h3>\n<p>IEC \uc7a5\ube44\uac00 \uc801\ud569\ud55c \uacbd\uc6b0:<\/p>\n<ul>\n<li><strong>\uc704\uce58:<\/strong> \uc720\ub7fd, \uc544\uc2dc\uc544, \uc544\ud504\ub9ac\uce74, \uc911\ub3d9 \ub610\ub294 IEC \uc6b0\uc138 \uc9c0\uc5ed<\/li>\n<li><strong>\uacf5\uac04 \uc81c\uc57d:<\/strong> \ucf64\ud329\ud2b8\ud55c \ubaa8\ub4c8\uc2dd \uc124\uacc4\ub85c \uc0ac\uc6a9 \uac00\ub2a5\ud55c \uacf5\uac04\uc744 \uadf9\ub300\ud654\ud558\ub294 \uc124\uce58<\/li>\n<li><strong>\uc0ac\uc6a9\uc790 \uc9c0\uc815:<\/strong> \uac80\uc99d\ub41c \uc2dc\uc2a4\ud15c \ub0b4\uc5d0\uc11c \uc720\uc5f0\ud55c \uad6c\uc131\uc744 \uc694\uad6c\ud558\ub294 \ud504\ub85c\uc81d\ud2b8<\/li>\n<li><strong>\uae00\ub85c\ubc8c \uc77c\uad00\uc131:<\/strong> \uc804 \uc138\uacc4 \uc7a5\ube44 \ud45c\uc900\ud654\ub97c \ucd94\uad6c\ud558\ub294 \ub2e4\uad6d\uc801 \uc2dc\uc124<\/li>\n<li><strong>\uacf5\uae09\ub9dd:<\/strong> IEC \uc81c\uc870\uc5c5\uccb4\uac00 \ub354 \ub098\uc740 \uac00\uaca9 \ub610\ub294 \ubc30\uc1a1\uc744 \uc81c\uacf5\ud558\ub294 \uc0c1\ud669<\/li>\n<\/ul>\n<h3>\ube44\uc6a9 \ubc0f \uac00\uc6a9\uc131 \uc694\uc18c<\/h3>\n<p>\uc9c0\uc5ed\ubcc4 \uc81c\uc870 \uc9d1\uc911\ub3c4\uac00 \uac00\uaca9\uc5d0 \uc601\ud5a5\uc744 \ubbf8\uce69\ub2c8\ub2e4. NEMA \uc7a5\ube44\ub294 \uc77c\ubc18\uc801\uc73c\ub85c \ubd81\ubbf8 \uc9c0\uc5ed \uc0dd\uc0b0 \ubc0f \uc720\ud1b5 \ub124\ud2b8\uc6cc\ud06c\ub85c \uc778\ud574 \ube44\uc6a9\uc774 \uc800\ub834\ud569\ub2c8\ub2e4. IEC \uc7a5\ube44\ub294 \uc720\ub7fd \ubc0f \uc544\uc2dc\uc544 \uc2dc\uc7a5\uc5d0\uc11c \uac00\uaca9 \uacbd\uc7c1\ub825\uc744 \uac16\uc2b5\ub2c8\ub2e4.<\/p>\n<p>\ub9ac\ub4dc \ud0c0\uc784\ub3c4 \uc720\uc0ac\ud55c \ud328\ud134\uc744 \ub530\ub985\ub2c8\ub2e4. \ud45c\uc900 NEMA \ubd80\ud558 \uc13c\ud130\ub294 \ubd81\ubbf8 \uc9c0\uc5ed \ub0b4\uc5d0\uc11c \ube60\ub974\uac8c \ubc30\uc1a1\ub418\uc9c0\ub9cc IEC \uc9c0\uc5ed\uc5d0\uc11c\ub294 \ubc30\uc1a1 \uc2dc\uac04\uc774 \uc5f0\uc7a5\ub420 \uc218 \uc788\uc2b5\ub2c8\ub2e4. IEC \ubc30\uc804\ubc18\uc740 \uc720\ub7fd \ubc0f \uc544\uc2dc\uc544\uc5d0\uc11c \uc9e7\uc740 \ub9ac\ub4dc \ud0c0\uc784\uc744 \uc81c\uacf5\ud558\uc9c0\ub9cc \ubd81\ubbf8 \ud504\ub85c\uc81d\ud2b8\uc5d0\ub294 \ub354 \uae34 \ubc30\uc1a1 \uc2dc\uac04\uc774 \uc18c\uc694\ub429\ub2c8\ub2e4.<\/p>\n<h3>\uc720\uc9c0 \ubcf4\uc218 \ubc0f \uc608\ube44 \ubd80\ud488 \uace0\ub824 \uc0ac\ud56d<\/h3>\n<p>\uc7a5\uae30 \uc6b4\uc601 \ube44\uc6a9\uc740 \uc608\ube44 \ubd80\ud488 \uac00\uc6a9\uc131\uc5d0 \ub530\ub77c \ub2ec\ub77c\uc9d1\ub2c8\ub2e4. \uc2dc\uc124\uc740 \uc124\uce58\ub41c \ud45c\uc900\uc5d0 \ub9de\ub294 \uad50\uccb4\uc6a9 \ucc28\ub2e8\uae30 \ubc0f \uad6c\uc131 \uc694\uc18c\ub97c \ube44\ucd95\ud574\uc57c \ud569\ub2c8\ub2e4. NEMA \ubd80\ud558 \uc13c\ud130\uac00 \uc788\ub294 \uc2dc\uc124\uc740 120\/240V \uc791\ub3d9 \uc815\uaca9\uc758 \ud50c\ub7ec\uadf8\uc778 \ucc28\ub2e8\uae30 \uc7ac\uace0\ub97c \uc720\uc9c0 \uad00\ub9ac\ud569\ub2c8\ub2e4. \ub098\uc911\uc5d0 IEC \uc7a5\ube44\ub85c \uc804\ud658\ud558\ub824\uba74 \uae30\uc874 \uc608\ube44 \ubd80\ud488 \uc7ac\uace0\ub97c \uad50\uccb4\ud574\uc57c \ud569\ub2c8\ub2e4.<\/p>\n<p>\uc778\ub825 \uad50\uc721\uc740 \ub610 \ub2e4\ub978 \uc9c0\uc18d\uc801\uc778 \ube44\uc6a9\uc785\ub2c8\ub2e4. NEMA \ubd80\ud558 \uc13c\ud130\uc5d0 \uc775\uc219\ud55c \uc804\uae30 \uae30\uc220\uc790\ub294 IEC \ubc30\uc804\ubc18\uc744 \uc11c\ube44\uc2a4\ud558\ub824\uba74 \uad50\uc721\uc774 \ud544\uc694\ud558\uba70 \uadf8 \ubc18\ub300\uc758 \uacbd\uc6b0\ub3c4 \ub9c8\ucc2c\uac00\uc9c0\uc785\ub2c8\ub2e4. \ub450 \ud45c\uc900\uc774 \ubaa8\ub450 \uc788\ub294 \uc2dc\uc124\uc740 \ub354 \uad11\ubc94\uc704\ud55c \uad50\uc721 \ud504\ub85c\uadf8\ub7a8\uacfc \uc7a0\uc7ac\uc801\uc73c\ub85c \uc804\ubb38 \uc720\uc9c0 \ubcf4\uc218 \ud300\uc774 \ud544\uc694\ud569\ub2c8\ub2e4.<\/p>\n<h2>\ub450 \ud45c\uc900\uc744 \uc704\ud55c VIOX \uc804\uae30 \uc194\ub8e8\uc158<\/h2>\n<p>VIOX Electric\uc740 NEMA \ubc0f IEC \ud45c\uc900\uc744 \ubaa8\ub450 \uc900\uc218\ud558\ub294 \ubc30\uc804 \uc7a5\ube44\ub97c \uc81c\uc870\ud558\uc5ec \uc804 \uc138\uacc4 \ubaa8\ub4e0 \uc9c0\uc5ed\uc758 \ud504\ub85c\uc81d\ud2b8\uc5d0 \uc720\uc5f0\uc131\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4. \ub2f9\uc0ac\uc758 \uc81c\uc870 \uc2dc\uc124\uc740 UL, CE \ubc0f \uae30\ud0c0 \uad6d\uc81c \uc778\uc99d \uae30\uad00\uc758 \uc778\uc99d\uc744 \uc720\uc9c0 \uad00\ub9ac\ud558\uc5ec \ud504\ub85c\uc81d\ud2b8 \uc704\uce58\uc5d0 \uad00\uacc4\uc5c6\uc774 \uc81c\ud488\uc774 \ud544\uc694\ud55c \ud45c\uc900\uc744 \ucda9\uc871\ud558\ub3c4\ub85d \ubcf4\uc7a5\ud569\ub2c8\ub2e4.<\/p>\n<h3>\ud3ec\uad04\uc801\uc778 \ud14c\uc2a4\ud2b8 \uae30\ub2a5<\/h3>\n<p>\ub2f9\uc0ac\uc758 \uc0ac\ub0b4 \ud14c\uc2a4\ud2b8 \uc5f0\uad6c\uc18c\ub294 UL 67 \ubc0f IEC 61439 \uc694\uad6c \uc0ac\ud56d\uc5d0 \ub530\ub77c \uac80\uc99d \ud14c\uc2a4\ud2b8\ub97c \uc218\ud589\ud569\ub2c8\ub2e4. \uc628\ub3c4 \uc0c1\uc2b9 \ud14c\uc2a4\ud2b8, \ub2e8\ub77d \ud14c\uc2a4\ud2b8, \uc720\uc804\uccb4 \ud14c\uc2a4\ud2b8 \ubc0f \uae30\uacc4\uc801 \ub0b4\uad6c\uc131 \ud14c\uc2a4\ud2b8\ub294 \uc0dd\uc0b0 \uc804\uc5d0 \uc124\uacc4\ub97c \uac80\uc99d\ud569\ub2c8\ub2e4. \uc774 \uc774\uc911 \ud45c\uc900 \uae30\ub2a5\uc744 \ud1b5\ud574 \ubaa8\ub4e0 \uaddc\uc81c \uad00\ud560 \uad6c\uc5ed\uc758 \ud504\ub85c\uc81d\ud2b8\uc5d0 \uc801\uc808\ud55c \ubb38\uc11c\ub97c \uc81c\uacf5\ud560 \uc218 \uc788\uc2b5\ub2c8\ub2e4.<\/p>\n<p>IEC 61439 \uc5b4\uc148\ube14\ub9ac\uc758 \uacbd\uc6b0 VIOX \uac80\uc99d \uc2dc\uc2a4\ud15c\uc744 \uc0ac\uc6a9\ud558\uc5ec \uc5b4\uc148\ube14\ub9ac\ub97c \uad6c\ucd95\ud558\ub294 \ud328\ub110 \ube4c\ub354\ub97c \uc9c0\uc6d0\ud558\ub294 \uac80\uc99d\ub41c \uc2dc\uc2a4\ud15c \ubc94\uc704\uc5d0 \ub300\ud55c \uc804\uccb4 \uc720\ud615 \ud14c\uc2a4\ud2b8 \ubb38\uc11c\ub97c \uc720\uc9c0 \uad00\ub9ac\ud569\ub2c8\ub2e4. NEMA \uc560\ud50c\ub9ac\ucf00\uc774\uc158\uc758 \uacbd\uc6b0 UL 67 \ubaa9\ub85d\uc740 \ud45c\uc900 \ubc0f \ub9de\ucda4\ud615 \ud328\ub110\ubcf4\ub4dc \uad6c\uc131\uc744 \ub2e4\ub8f9\ub2c8\ub2e4.<\/p>\n<h3>\uc0ac\uc591 \uc9c0\uc6d0\uc744 \uc704\ud55c \uae30\uc220 \uc9c0\uc6d0<\/h3>\n<p>VIOX \uae30\uc220 \uc9c0\uc6d0 \ud300\uc740 \uc5d4\uc9c0\ub2c8\uc5b4\uac00 \ud2b9\uc815 \uc560\ud50c\ub9ac\ucf00\uc774\uc158\uc5d0 \uc801\ud569\ud55c \uc7a5\ube44\ub97c \uc120\ud0dd\ud558\ub3c4\ub85d \uc9c0\uc6d0\ud569\ub2c8\ub2e4. \ud504\ub85c\uc81d\ud2b8\uc5d0 NEMA \ubd80\ud558 \uc13c\ud130, IEC \ubc30\uc804\ubc18 \ub610\ub294 \ub458 \ub2e4 \ud544\uc694\ud55c\uc9c0 \uc5ec\ubd80\uc5d0 \uad00\uacc4\uc5c6\uc774 \ub2f9\uc0ac\uc758 \uc804\ubb38\uac00\ub294 \uae30\uc220 \uc694\uad6c \uc0ac\ud56d\uc744 \ucda9\uc871\ud558\ub294 \ub3d9\uc2dc\uc5d0 \ube44\uc6a9 \ubc0f \ubc30\uc1a1 \uc77c\uc815\uc744 \ucd5c\uc801\ud654\ud558\ub294 \uad6c\uc131\uc744 \uad8c\uc7a5\ud560 \uc218 \uc788\uc2b5\ub2c8\ub2e4.<\/p>\n<p>\ub2f9\uc0ac\uc758 \uc5d4\uc9c0\ub2c8\uc5b4\ub9c1 \ud300\uc740 \ub610\ud55c \ud45c\uc900 \uac04 \uc804\ud658 \ud504\ub85c\uc81d\ud2b8\ub97c \uc9c0\uc6d0\ud560 \uc218 \uc788\uc2b5\ub2c8\ub2e4. \uc608\ub97c \ub4e4\uc5b4 \ub2e4\uad6d\uc801 \uc2dc\uc124 \ud45c\uc900\ud654 \ud504\ub85c\uadf8\ub7a8\uc744 \uc704\ud55c IEC \ub3d9\uae09 \uc7a5\ube44\ub97c \uc9c0\uc815\ud558\uac70\ub098 \uae30\uc874 NEMA \uc778\ud504\ub77c\uac00 \uc788\ub294 IEC \uc9c0\uc5ed\uc758 \uc2dc\uc124\uc5d0 \ub300\ud55c NEMA \uc7a5\ube44\ub97c \uc2dd\ubcc4\ud558\ub294 \uac83\uc785\ub2c8\ub2e4.<\/p>\n<p>\ub2f9\uc0ac\uc758 \ubd80\ud558 \uc13c\ud130 \ubc0f \ubc30\uc804\ubc18 \uc81c\ud488 \ub77c\uc778\uc5d0 \ub300\ud55c \uc790\uc138\ud55c \uae30\uc220 \uc0ac\uc591\uc740 \ub2f9\uc0ac\uc758 \uc804\uccb4 \uc81c\ud488 \ub77c\uc778\uc744 \uc0b4\ud3b4\ubcf4\uc2ed\uc2dc\uc624. <a href=\"https:\/\/test.viox.com\/ko\/switchgear-current-ratings-ina-inc-rdf-guide\/\">\uac1c\ud3d0 \uc7a5\uce58 \uc804\ub958 \uc815\uaca9 \uac00\uc774\ub4dc<\/a>, IEC 61439\uc5d0 \ub530\ub978 InA, Inc \ubc0f RDF \uc815\uaca9\uc744 \ub2e4\ub8f9\ub2c8\ub2e4. \ub610\ud55c \ub2f9\uc0ac\ub294 <a href=\"https:\/\/test.viox.com\/ko\/on-grid-vs-off-grid-solar-distribution-box-selection-guide\/\">\ud0dc\uc591\uad11 \ubc30\uc804 \uc560\ud50c\ub9ac\ucf00\uc774\uc158\uc744 \uc704\ud55c \ubcf4\ud638 \uad6c\uc131 \uc694\uc18c \uc120\ud0dd<\/a>, \ub2e4\uc591\ud55c \uc804\uae30 \ubc30\uc804 \uc2dc\ub098\ub9ac\uc624\uc5d0 \ub300\ud55c \ub2f9\uc0ac\uc758 \uc804\ubb38\uc131\uc744 \uc785\uc99d\ud569\ub2c8\ub2e4. \ub2f9\uc0ac\uc758 \ud300\uc740 <a href=\"https:\/\/test.viox.com\/ko\/nec-vs-iec-terminology-correspondence\/\">NEC \ubc0f IEC \uc6a9\uc5b4 \ud45c\uc900<\/a>, \uaddc\uc81c \uad00\ud560 \uad6c\uc5ed \uc804\ubc18\uc5d0 \uac78\uccd0 \uc815\ud655\ud55c \uc0ac\uc591\uc744 \ubcf4\uc7a5\ud569\ub2c8\ub2e4.<\/p>\n<h2>\uacb0\ub860<\/h2>\n<p>\ubd80\ud558 \uc13c\ud130\uc640 \ubc30\uc804\ubc18\uc740 \uc11c\ub85c \ub2e4\ub978 \uaddc\uc81c \ud504\ub808\uc784\uc6cc\ud06c\uc758 \uc801\uc6a9\uc744 \ubc1b\ub294 \uae30\ub2a5\uc801\uc73c\ub85c \ub3d9\ub4f1\ud55c \uc7a5\ube44\uc5d0 \ub300\ud55c \uc9c0\uc5ed\ubcc4 \uc6a9\uc5b4\ub97c \ub098\ud0c0\ub0c5\ub2c8\ub2e4. NEMA \ud45c\uc900\uc740 UL 67 \ubc0f NEMA PB1\uc758 \uaddc\ubc94\uc801 \uc694\uad6c \uc0ac\ud56d\uc744 \ud1b5\ud574 \ubd81\ubbf8 \uc2dc\uc7a5\uc5d0 \uc11c\ube44\uc2a4\ub97c \uc81c\uacf5\ud558\ub294 \ub0b4\uc7a5\ub41c \uc548\uc804 \uacc4\uc218\ub97c \uac16\ucd98 \uacac\uace0\ud55c \uad6c\uc870\ub97c \uac15\uc870\ud569\ub2c8\ub2e4. IEC \ud45c\uc900\uc740 IEC 61439\uc5d0 \ub530\ub978 \uc131\ub2a5 \uae30\ubc18 \uac80\uc99d\uc744 \uc911\uc2ec\uc73c\ub85c \ud558\ub294 \uae00\ub85c\ubc8c \ud504\ub808\uc784\uc6cc\ud06c\ub97c \uc81c\uacf5\ud558\uc5ec \uc815\uc758\ub41c \uc548\uc804 \ub9e4\uac1c\ubcc0\uc218 \ub0b4\uc5d0\uc11c \uc124\uacc4 \uc720\uc5f0\uc131\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4.<\/p>\n<p>\uc5b4\ub5a4 \ud45c\uc900\ub3c4 \ubcf8\uc9c8\uc801\uc73c\ub85c \uc6b0\uc218\ud558\uc9c0 \uc54a\uc2b5\ub2c8\ub2e4. \uac01 \ud45c\uc900\uc740 \uc9c0\uc5ed \uc804\uae30 \uc778\ud504\ub77c, \uaddc\uc81c \ud658\uacbd \ubc0f \uc0b0\uc5c5 \uad00\ud589\uc5d0 \ub9de\uac8c \uc9c4\ud654\ud588\uc2b5\ub2c8\ub2e4. \ud604\ub300 \uc804\uae30 \uc5d4\uc9c0\ub2c8\uc5b4\ub294 \uad6d\uc81c \uacbd\uacc4\ub97c \ub118\ub098\ub4dc\ub294 \ud504\ub85c\uc81d\ud2b8 \ub610\ub294 \ub2e4\uad6d\uc801 \uc870\uc9c1\uc5d0 \uc11c\ube44\uc2a4\ub97c \uc81c\uacf5\ud558\ub294 \ud504\ub85c\uc81d\ud2b8\uc5d0 \uc801\ud569\ud55c \uc7a5\ube44\ub97c \uc9c0\uc815\ud558\ub824\uba74 \ub450 \ud504\ub808\uc784\uc6cc\ud06c\ub97c \ubaa8\ub450 \uc774\ud574\ud574\uc57c \ud569\ub2c8\ub2e4.<\/p>\n<p>\ud504\ub85c\uc81d\ud2b8\uc5d0 \uc801\ud569\ud55c \ud45c\uc900\uc744 \uc120\ud0dd\ud558\ub294 \uac83\uc740 \uc704\uce58, \uaddc\uc81c \uc694\uad6c \uc0ac\ud56d, \uc0ac\uc6a9 \uac00\ub2a5\ud55c \uc804\ubb38 \uc9c0\uc2dd \ubc0f \uc7a5\uae30\uc801\uc778 \uc6b4\uc601 \uace0\ub824 \uc0ac\ud56d\uc5d0 \ub530\ub77c \ub2e4\ub985\ub2c8\ub2e4. NEMA \ubc0f IEC \ud45c\uc900 \ubaa8\ub450\uc5d0 \ub300\ud55c \uc804\ubb38 \uc9c0\uc2dd\uc744 \uc720\uc9c0 \uad00\ub9ac\ud558\ub294 VIOX Electric\uacfc \uac19\uc740 \uc81c\uc870\uc5c5\uccb4\uc640 \ud611\ub825\ud558\uba74 \ud504\ub85c\uc81d\ud2b8 \uc704\uce58 \ub610\ub294 \uaddc\uc81c \uad00\ud560 \uad6c\uc5ed\uc5d0 \uad00\uacc4\uc5c6\uc774 \uc801\uc808\ud55c \uc7a5\ube44 \uc0ac\uc591\uc744 \ubcf4\uc7a5\ud560 \uc218 \uc788\uc2b5\ub2c8\ub2e4.<\/p>\n<figure style=\"text-align: center; margin: 20px 0;\">\n        <img decoding=\"async\" src=\"https:\/\/img.viox.com\/World-map-showing-NEMA-and-IEC-standards-geographic-distribution-with-decision-flowchart-for-specification-selection.webp\" alt=\"World map showing NEMA and IEC standards geographic distribution with decision flowchart for specification selection\" style=\"max-width: 100%; height: auto;\"><figcaption style=\"font-style: italic; color: #555; margin-top: 8px;\">\uadf8\ub9bc 5: NEMA \ubc0f IEC \ud45c\uc900 \uc9c0\ub9ac\uc801 \ubd84\ud3ec\uc640 \uc0ac\uc591 \uc120\ud0dd\uc744 \uc704\ud55c \uc758\uc0ac \uacb0\uc815 \ud750\ub984\ub3c4\ub97c \uacb0\ud569\ud55c \uae00\ub85c\ubc8c \uc9c0\ub3c4.<\/figcaption><\/figure>\n<h2>\uc790\uc8fc \ubb3b\ub294 \uc9c8\ubb38<\/h2>\n<h3>Q1: IEC \ubc30\uc804\ubc18\uc73c\ub85c \uc9c0\uc815\ub41c \ud504\ub85c\uc81d\ud2b8\uc5d0\uc11c NEMA \ubd80\ud558 \uc13c\ud130\ub97c \uc0ac\uc6a9\ud560 \uc218 \uc788\uc2b5\ub2c8\uae4c?<\/h3>\n<p>\uc544\ub2c8\uc694, NEMA \ubd80\ud558 \uc13c\ud130\uc640 IEC \ubc30\uc804\ubc18\uc740 \uacf5\uc2dd\uc801\uc778 \uc5d4\uc9c0\ub2c8\uc5b4\ub9c1 \ubd84\uc11d \ubc0f \uaddc\uc81c \uc2b9\uc778 \uc5c6\uc774\ub294 \uc0c1\ud638 \uad50\ud658\ud560 \uc218 \uc5c6\uc2b5\ub2c8\ub2e4. \uc774\ub4e4\uc740 \uc11c\ub85c \ub2e4\ub978 \uac74\uc124 \ud45c\uc900\uc744 \ub530\ub974\uace0, \ud68c\ub85c \ucc28\ub2e8\uae30\uc5d0 \ub300\ud55c \ud638\ud658\ub418\uc9c0 \uc54a\ub294 \uc7a5\ucc29 \uc2dc\uc2a4\ud15c\uc744 \uc0ac\uc6a9\ud558\uace0, \uc11c\ub85c \ub2e4\ub978 \uac80\uc99d \ubb38\uc11c\uac00 \ud544\uc694\ud569\ub2c8\ub2e4. \uc9c0\uc815\ub41c \ud45c\uc900\uacfc \uc77c\uce58\ud558\uc9c0 \uc54a\ub294 \uc7a5\ube44\ub97c \uc0ac\uc6a9\ud558\uba74 \ucf54\ub4dc \uc900\uc218 \ubb38\uc81c\uac00 \ubc1c\uc0dd\ud558\uace0, \ubcf4\uc99d\uc774 \ubb34\ud6a8\ud654\ub418\uace0, \uc548\uc804 \uc704\ud5d8\uc774 \ubc1c\uc0dd\ud560 \uc218 \uc788\uc2b5\ub2c8\ub2e4. \ud504\ub85c\uc81d\ud2b8 \uc704\uce58 \ub610\ub294 \uc0ac\uc591\uc5d0 IEC \uc7a5\ube44\uac00 \ud544\uc694\ud55c \uacbd\uc6b0 NEMA \ubd80\ud558 \uc13c\ud130\uac00 \uc544\ub2cc IEC 61439\ub97c \uc900\uc218\ud558\ub294 \ubc30\uc804\ubc18\uc744 \uc0ac\uc6a9\ud574\uc57c \ud569\ub2c8\ub2e4.<\/p>\n<h3>Q2: UL 67\uacfc IEC 61439-3\uc758 \uc8fc\uc694 \ucc28\uc774\uc810\uc740 \ubb34\uc5c7\uc785\ub2c8\uae4c?<\/h3>\n<p>UL 67\uc740 \uaddc\uc815\uc801 \uc811\uadfc \ubc29\uc2dd\uc744 \ub530\ub974\uba70, \uc81c\uc870\uc5c5\uccb4\uac00 \uc815\ud655\ud788 \uc900\uc218\ud574\uc57c \ud558\ub294 \ud2b9\uc815 \uad6c\uc870 \uc694\uad6c \uc0ac\ud56d, \uc7ac\ub8cc \ubc0f \ud14c\uc2a4\ud2b8 \uc808\ucc28\ub97c \uc815\uc758\ud569\ub2c8\ub2e4. IEC 61439-3\uc740 \uc131\ub2a5 \uae30\ubc18 \uc811\uadfc \ubc29\uc2dd\uc744 \uc0ac\uc6a9\ud558\uc5ec \ud544\uc694\ud55c \uc131\ub2a5 \uc218\uc900(\uc628\ub3c4 \uc0c1\uc2b9 \uc81c\ud55c, \ub2e8\ub77d \ub0b4\uc131 \ub4f1)\uc744 \uc9c0\uc815\ud558\ub294 \ub3d9\uc2dc\uc5d0 \uc81c\uc870\uc5c5\uccb4\uac00 \uc124\uacc4 \uac80\uc99d\uc744 \ud1b5\ud574 \uc774\ub7ec\ud55c \uc218\uc900\uc744 \ub2ec\uc131\ud558\ub294 \ubc29\ubc95\uc5d0 \ub300\ud55c \uc720\uc5f0\uc131\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4. \ub610\ud55c UL 67\uc740 \uc0b0\uc5c5\uc6a9 \ubc30\uc804\ubc18\uc744 \ud3ec\ud568\ud55c \uad11\ubc94\uc704\ud55c \ubc30\uc804\ubc18\uc744 \ub2e4\ub8e8\ub294 \ubc18\uba74, IEC 61439-3\uc740 \ud2b9\ud788 \uc77c\ubc18\uc778\uc774 \uc791\ub3d9\ud558\ub294 \ubc30\uc804\ubc18(DBO)\uc744 \ub300\uc0c1\uc73c\ub85c \ud558\uba70 \uc8fc\uac70 \ubc0f \uacbd\uc0c1\uc5c5\uc6a9 \uc560\ud50c\ub9ac\ucf00\uc774\uc158\uc5d0 \uc801\ud569\ud55c \uc804\ub958 \ubc0f \uc804\uc555 \uc81c\ud55c\uc744 \uac16\uc2b5\ub2c8\ub2e4.<\/p>\n<h3>Q3: NEMA \ubc0f IEC \ud68c\ub85c \ucc28\ub2e8\uae30\ub97c \uc0c1\ud638 \uad50\ud658\ud560 \uc218 \uc788\uc2b5\ub2c8\uae4c?<\/h3>\n<p>\uc544\ub2c8\uc694, NEMA\uc640 IEC \ud68c\ub85c \ucc28\ub2e8\uae30\ub294 \uae30\uacc4\uc801, \uc804\uae30\uc801\uc73c\ub85c \ud638\ud658\ub418\uc9c0 \uc54a\uc2b5\ub2c8\ub2e4. NEMA \ucc28\ub2e8\uae30\ub294 \ud2b9\uc815 \uac04\uaca9(\uc77c\ubc18\uc801\uc73c\ub85c \uc8fc\uac70\uc6a9 \ubd80\ud558 \uc911\uc2ec\uc758 \uacbd\uc6b0 1\uc778\uce58 \uc911\uc2ec)\uc73c\ub85c \ud328\ub110\ubcf4\ub4dc \ubc84\uc2a4 \ubc14\uc5d0 \ud50c\ub7ec\uadf8\uc628 \ub610\ub294 \ubcfc\ud2b8\uc628 \uc5f0\uacb0\uc744 \uc0ac\uc6a9\ud569\ub2c8\ub2e4. IEC \ucc28\ub2e8\uae30\ub294 \ub2e4\ub978 \uae30\uacc4\uc801 \uc778\ud130\ud398\uc774\uc2a4\uc640 \uac04\uaca9\uc73c\ub85c DIN \ub808\uc77c\uc5d0 \uc7a5\ucc29\ub429\ub2c8\ub2e4. \uae30\uacc4\uc801 \ucc28\uc774 \uc678\uc5d0\ub3c4 \ud2b8\ub9bd \ud2b9\uc131, \ud14c\uc2a4\ud2b8 \ud45c\uc900 \ubc0f \ub9c8\ud0b9 \uc694\uad6c \uc0ac\ud56d\uc740 NEMA(UL 489)\uc640 IEC(IEC 60898) \ucc28\ub2e8\uae30 \uac04\uc5d0 \ub2e4\ub985\ub2c8\ub2e4. \uc798\ubabb\ub41c \ucc28\ub2e8\uae30 \uc720\ud615\uc744 \uc124\uce58\ud558\uba74 \ubd88\ub7c9\ud55c \uc804\uae30 \uc5f0\uacb0, \ubd80\uc801\uc808\ud55c \uace0\uc7a5 \ubcf4\ud638 \ubc0f \ubaa9\ub85d \uc694\uad6c \uc0ac\ud56d \uc704\ubc18\uc744 \ud3ec\ud568\ud55c \uc2ec\uac01\ud55c \uc548\uc804 \uc704\ud5d8\uc774 \ubc1c\uc0dd\ud569\ub2c8\ub2e4.<\/p>\n<h3>Q4: \uc5b4\ub5a4 \ud45c\uc900\uc774 \ub354 \uc5c4\uaca9\ud569\ub2c8\uae4c? NEMA \ub610\ub294 IEC?<\/h3>\n<p>\ub450 \ud45c\uc900 \ubaa8\ub450 \ubcf8\uc9c8\uc801\uc73c\ub85c \ub354 \uc5c4\uaca9\ud558\uac70\ub098 \ub35c \uc5c4\uaca9\ud55c \uac83\uc740 \uc544\ub2c8\uba70, \uc548\uc804 \ubc0f \uc131\ub2a5\uc758 \uc11c\ub85c \ub2e4\ub978 \uce21\uba74\uc744 \uac15\uc870\ud569\ub2c8\ub2e4. NEMA \ud45c\uc900\uc740 \uc77c\ubc18\uc801\uc73c\ub85c \ub354 \ud070 \uc548\uc804 \uacc4\uc218\uc640 \ub354 \uacac\uace0\ud55c \uad6c\uc870\ub97c \uc694\uad6c\ud558\ubbc0\ub85c \uc7a5\ube44\uac00 \uc124\uacc4 \ud55c\uacc4 \uadfc\ucc98\uc5d0\uc11c \uc791\ub3d9\ud560 \uac00\ub2a5\uc131\uc774 \uc801\uc2b5\ub2c8\ub2e4. IEC \ud45c\uc900\uc740 \ud615\uc2dd \ud14c\uc2a4\ud2b8\ub97c \ud1b5\ud574 \ub354 \uc790\uc138\ud55c \uc131\ub2a5 \uac80\uc99d\uc744 \uc694\uad6c\ud558\uc9c0\ub9cc \ud65c\uc6a9 \ubc94\uc8fc\ub97c \ud1b5\ud574 \uc801\uc808\ud558\uac8c \uc801\uc6a9\ub420 \uacbd\uc6b0 \ud14c\uc2a4\ud2b8\ub41c \ud55c\uacc4\uc5d0 \ub354 \uac00\uae5d\uac8c \uc791\ub3d9\ud560 \uc218 \uc788\uc2b5\ub2c8\ub2e4. \ub450 \ud45c\uc900 \ubaa8\ub450 \uc7a5\ube44\uac00 \uc62c\ubc14\ub974\uac8c \uc9c0\uc815, \uc124\uce58 \ubc0f \uc720\uc9c0 \uad00\ub9ac\ub420 \ub54c \uc548\uc804\uc744 \ud6a8\uacfc\uc801\uc73c\ub85c \ubcf4\uc7a5\ud569\ub2c8\ub2e4. \uc8fc\uc694 \ucc28\uc774\uc810\uc740 \ucca0\ud559\uc5d0 \uc788\uc2b5\ub2c8\ub2e4. NEMA\ub294 \ubcf4\uc218\uc801\uc778 \uc124\uacc4 \ub9c8\uc9c4\uc744 \uc120\ud638\ud558\uace0 IEC\ub294 \uad6c\uc131 \uc694\uc18c\uc758 \uae30\ub2a5\uc744 \uc560\ud50c\ub9ac\ucf00\uc774\uc158 \uc694\uad6c \uc0ac\ud56d\uc5d0 \uc815\ud655\ud558\uac8c \uc77c\uce58\uc2dc\ud0a4\ub294 \uac83\uc744 \uc120\ud638\ud569\ub2c8\ub2e4.<\/p>\n<h3>Q5: NEMA AIC \uc815\uaca9\uacfc IEC \ub2e8\ub77d \uc815\uaca9 \uac04\uc5d0 \uc5b4\ub5bb\uac8c \ubcc0\ud658\ud569\ub2c8\uae4c?<\/h3>\n<p>NEMA AIC \uc815\uaca9\uacfc IEC Icw\/Ipk \uc815\uaca9 \uac04\uc758 \uc9c1\uc811\uc801\uc778 \ubcc0\ud658\uc740 \ub2e8\ub77d \ud68c\ub85c \uc131\ub2a5\uc758 \uc11c\ub85c \ub2e4\ub978 \uce21\uba74\uc744 \uce21\uc815\ud558\uae30 \ub54c\ubb38\uc5d0 \uac04\ub2e8\ud558\uc9c0 \uc54a\uc2b5\ub2c8\ub2e4. NEMA AIC(\ucc28\ub2e8 \uc6a9\ub7c9)\ub294 \ucc28\ub2e8\uae30\uac00 \ucc28\ub2e8\ud558\uace0 \uc81c\uac70\ud560 \uc218 \uc788\ub294 \ucd5c\ub300 \ub300\uce6d RMS \uace0\uc7a5 \uc804\ub958\ub97c \ub098\ud0c0\ub0c5\ub2c8\ub2e4. IEC Icw(\ub2e8\uc2dc\uac04 \ub0b4\uc804\ub958)\ub294 \uc5b4\uc148\ube14\ub9ac\uac00 \ud2b9\uc815 \uc2dc\uac04(\uc77c\ubc18\uc801\uc73c\ub85c 1\ucd08) \ub3d9\uc548 \uacac\ub51c \uc218 \uc788\ub294 RMS \uc804\ub958 \ub808\ubca8\uc744 \ub098\ud0c0\ub0b4\uace0, Ipk(\ucd5c\ub300 \ub0b4\uc804\ub958)\ub294 \ucd5c\ub300 \uc21c\uac04 \ud53c\ud06c \uc804\ub958\ub97c \ub098\ud0c0\ub0c5\ub2c8\ub2e4. \ub300\ub7b5\uc801\uc778 \uadfc\uc0ac\uce58\ub85c IEC Icw\uc5d0 2.5\ub97c \uacf1\ud558\uc5ec \ud53c\ud06c \uace0\uc7a5 \uc804\ub958\ub97c \ucd94\uc815\ud560 \uc218 \uc788\uc9c0\ub9cc \uc774\ub294 \uc2dc\uc2a4\ud15c X\/R \ube44\uc728\uc5d0 \ub530\ub77c \ub2e4\ub985\ub2c8\ub2e4. \uc911\uc694\ud55c \uc560\ud50c\ub9ac\ucf00\uc774\uc158\uc758 \uacbd\uc6b0 \uc9c1\uc811 \ubcc0\ud658\uc744 \uc2dc\ub3c4\ud558\uae30\ubcf4\ub2e4\ub294 \uc81c\uc870\uc5c5\uccb4\uc5d0 \ubb38\uc758\ud558\uc5ec \uc801\uc808\ud55c \uace0\uc7a5 \uc804\ub958 \ubd84\uc11d\uc744 \uc218\ud589\ud558\uc2ed\uc2dc\uc624. \uae30\ubcf8\uc801\uc778 \ud14c\uc2a4\ud2b8 \ubc29\ubc95\uacfc \uc548\uc804 \ucca0\ud559\uc774 \ud45c\uc900 \uac04\uc5d0 \uadfc\ubcf8\uc801\uc73c\ub85c \ub2e4\ub974\uae30 \ub54c\ubb38\uc785\ub2c8\ub2e4.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>When a European contractor recently submitted specifications for a 400V distribution board on a North American manufacturing facility project, the procurement team faced an unexpected challenge: the local electrical inspector rejected the equipment citing non-compliance with UL 67 standards. The root cause? A fundamental misunderstanding between &#8220;load centers&#8221; and &#8220;distribution boards&#8221;\u2014two terms describing functionally similar [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":21305,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1],"tags":[],"class_list":["post-21304","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"_links":{"self":[{"href":"https:\/\/test.viox.com\/ko\/wp-json\/wp\/v2\/posts\/21304","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/test.viox.com\/ko\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/test.viox.com\/ko\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/test.viox.com\/ko\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/test.viox.com\/ko\/wp-json\/wp\/v2\/comments?post=21304"}],"version-history":[{"count":1,"href":"https:\/\/test.viox.com\/ko\/wp-json\/wp\/v2\/posts\/21304\/revisions"}],"predecessor-version":[{"id":21306,"href":"https:\/\/test.viox.com\/ko\/wp-json\/wp\/v2\/posts\/21304\/revisions\/21306"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/test.viox.com\/ko\/wp-json\/wp\/v2\/media\/21305"}],"wp:attachment":[{"href":"https:\/\/test.viox.com\/ko\/wp-json\/wp\/v2\/media?parent=21304"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/test.viox.com\/ko\/wp-json\/wp\/v2\/categories?post=21304"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/test.viox.com\/ko\/wp-json\/wp\/v2\/tags?post=21304"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}