{"id":20883,"date":"2025-12-16T23:03:20","date_gmt":"2025-12-16T15:03:20","guid":{"rendered":"https:\/\/viox.com\/?p=20883"},"modified":"2025-12-16T23:04:33","modified_gmt":"2025-12-16T15:04:33","slug":"timer-relay-voltage-selection-guide-12v-24v-120v-230v","status":"publish","type":"post","link":"https:\/\/test.viox.com\/ko\/timer-relay-voltage-selection-guide-12v-24v-120v-230v\/","title":{"rendered":"12V, 24V, 120V \ubc0f 230V \ud0c0\uc774\uba38 \ub9b4\ub808\uc774 \uc911\uc5d0\uc11c \uc120\ud0dd"},"content":{"rendered":"<div class=\"product-intro\">\n<p>\ud0c0\uc774\uba38 \ub9b4\ub808\uc774\uc5d0 \uc801\ud569\ud55c \uc81c\uc5b4 \uc804\uc555(12V, 24V, 120V \ub610\ub294 230V)\uc744 \uc120\ud0dd\ud558\ub294 \uac83\uc740 \uc2dc\uc2a4\ud15c \uc548\uc804, \ud638\ud658\uc131 \ubc0f \uc2e0\ub8b0\uc131\uc5d0 \uc9c1\uc811\uc801\uc778 \uc601\ud5a5\uc744 \ubbf8\uce69\ub2c8\ub2e4. 24V DC\ub294 \uc548\uc804 \uc774\uc810\uacfc PLC \ud638\ud658\uc131\uc73c\ub85c \uc778\ud574 \uc0b0\uc5c5 \uc790\ub3d9\ud654\uc758 \ucd5c\uc2e0 \ud45c\uc900\uc774 \ub418\uc5c8\uc9c0\ub9cc, 12V\ub294 \ubaa8\ubc14\uc77c \ubc0f \ubc30\ud130\ub9ac \uc804\uc6d0 \uc560\ud50c\ub9ac\ucf00\uc774\uc158\uc5d0 \uc801\ud569\ud558\uace0, 120V\/230V AC \uc635\uc158\uc740 \uace0\uc804\ub825 \uc7a5\ube44 \ubc0f \uc9c0\uc5ed \uc8fc\uc804\uc6d0 \uc2dc\uc2a4\ud15c\uc5d0 \uc5ec\uc804\ud788 \ud544\uc218\uc801\uc785\ub2c8\ub2e4. \uc774 \uac00\uc774\ub4dc\ub294 \uc5d4\uc9c0\ub2c8\uc5b4, \uc2dc\uc2a4\ud15c \ud1b5\ud569\uc790 \ubc0f \uc870\ub2ec \uc804\ubb38\uac00\uac00 \ubaa8\ub4e0 \uc81c\uc5b4 \uc2dc\uc2a4\ud15c\uc5d0 \ucd5c\uc801\uc758 \ud0c0\uc774\uba38 \ub9b4\ub808\uc774 \uc804\uc555\uc744 \uc9c0\uc815\ud558\ub294 \ub370 \ub3c4\uc6c0\uc774 \ub418\ub294 \uc758\uc0ac \uacb0\uc815 \ud504\ub808\uc784\uc6cc\ud06c, \ube44\uad50 \ud14c\uc774\ube14 \ubc0f \uc560\ud50c\ub9ac\ucf00\uc774\uc158\ubcc4 \uad8c\uc7a5 \uc0ac\ud56d\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4.<\/p>\n<p>\ud0c0\uc774\uba38 \ub9b4\ub808\uc774\ub294 \uc0b0\uc5c5, \uc0c1\uc5c5 \ubc0f \uc8fc\uac70 \uc560\ud50c\ub9ac\ucf00\uc774\uc158 \uc804\ubc18\uc5d0\uc11c \uc815\ud655\ud55c \uc2dc\uac04 \uae30\ubc18 \uc790\ub3d9\ud654\ub97c \uac00\ub2a5\ud558\uac8c \ud558\ub294 \uae30\ubcf8\uc801\uc778 \uc81c\uc5b4 \uad6c\uc131 \uc694\uc18c\uc785\ub2c8\ub2e4. \uc9c0\uc815\ud558\ub294 \uc81c\uc5b4 \uc804\uc555\uc740 \uc2dc\uc2a4\ud15c \ud638\ud658\uc131, \uc124\uce58 \uc548\uc804 \ubc0f \uc7a5\uae30\uc801\uc778 \uc2e0\ub8b0\uc131\uc744 \uacb0\uc815\ud569\ub2c8\ub2e4.<\/p>\n<figure style=\"text-align: center; margin: 20px 0;\"><img decoding=\"async\" style=\"max-width: 100%; height: auto;\" src=\"https:\/\/img.viox.com\/viox-timer-relay-mounted-on-din-rail-in-industrial-control-panel-with-led-indicators-and-voltage-adjustment-dial-professional-product-photography.png.webp\" alt=\"VIOX timer relay mounted on DIN rail in industrial control panel with LED indicators and voltage adjustment dial, professional product photography\" \/><figcaption style=\"color: #666; font-style: italic; margin-top: 8px;\">\uadf8\ub9bc 1: VIOX <a href=\"https:\/\/test.viox.com\/ko\/timer-relay\/\">\ub9b4\ub808\uc774 \ud0c0\uc774\uba38<\/a> \uc7a5\ucc29\ub428 <a href=\"https:\/\/test.viox.com\/ko\/din-rail\/\">DIN \ub808\uc77c<\/a> \uba85\ud655\ud55c LED \ud45c\uc2dc\ub4f1\uacfc \uc815\ud655\ud55c \uc804\uc555 \uc870\uc815 \ucee8\ud2b8\ub864\uc774 \uc788\uc2b5\ub2c8\ub2e4.<\/figcaption><\/figure>\n<h2>\ud0c0\uc774\uba38 \ub9b4\ub808\uc774 \uc81c\uc5b4 \uc804\uc555 \uc774\ud574<\/h2>\n<p>\uc81c\uc5b4 \uc804\uc555(\ucf54\uc77c \uc804\uc555 \ub610\ub294 \uc791\ub3d9 \uc804\uc555\uc774\ub77c\uace0\ub3c4 \ud568)\uc740 \ud0c0\uc774\uba38 \ub9b4\ub808\uc774\uc758 \ub0b4\ubd80 \ucf54\uc77c\uc5d0 \uc804\uc6d0\uc744 \uacf5\uae09\ud558\uace0 \uc2a4\uc704\uce6d \uba54\ucee4\ub2c8\uc998\uc744 \ud65c\uc131\ud654\ud558\ub294 \ub370 \ud544\uc694\ud55c \uc804\uae30 \uc2e0\ud638\uc785\ub2c8\ub2e4. \uc774 \uc804\uc555\uc740 \ub9b4\ub808\uc774\uc758 \ud0c0\uc774\ubc0d \ud68c\ub85c\uc640 \uc804\uc790\uc11d\uc5d0 \uc804\uc6d0\uc744 \uacf5\uae09\ud558\uc5ec \uc7a5\uce58\uac00 \uc2dc\uac04 \uac04\uaca9\uc744 \uce21\uc815\ud558\uace0 \ud6e8\uc52c \ub354 \ub192\uc740 \uc804\uc555\uacfc \uc804\ub958\ub97c \uc804\ud658\ud560 \uc218 \uc788\ub294 \ucd9c\ub825 \uc811\uc810\uc744 \uc81c\uc5b4\ud560 \uc218 \uc788\ub3c4\ub85d \ud569\ub2c8\ub2e4.<\/p>\n<h3>\uc81c\uc5b4 \uc804\uc555\uc774 \uc911\uc694\ud55c \uc774\uc720<\/h3>\n<p>\uc62c\ubc14\ub978 \uc81c\uc5b4 \uc804\uc555\uc744 \uc9c0\uc815\ud558\ub294 \uac83\uc740 \uc138 \uac00\uc9c0 \uc8fc\uc694 \uc774\uc720\ub85c \uc911\uc694\ud569\ub2c8\ub2e4.<\/p>\n<p><strong>\uc2dc\uc2a4\ud15c \ud638\ud658\uc131<\/strong>: \ud0c0\uc774\uba38 \ub9b4\ub808\uc774\ub294 \uae30\uc874 \uc81c\uc5b4 \uc2dc\uc2a4\ud15c \uc804\uc555\uacfc \uc77c\uce58\ud574\uc57c \ud569\ub2c8\ub2e4. 24V DC \uc2e0\ud638\ub97c \ucd9c\ub825\ud558\ub294 PLC\ub294 \ucd94\uac00 \uc778\ud130\ud398\uc774\uc2a4 \uc7a5\ube44 \uc5c6\uc774 120V AC \ub9b4\ub808\uc774\ub97c \uc9c1\uc811 \uad6c\ub3d9\ud560 \uc218 \uc5c6\uc2b5\ub2c8\ub2e4. \uc804\uc555\uc774 \uc77c\uce58\ud558\uc9c0 \uc54a\uc73c\uba74 \uc791\ub3d9\uc774 \uc911\ub2e8\ub418\uac70\ub098 \ube44\uc6a9\uc774 \ub9ce\uc774 \ub4dc\ub294 \ubcc0\ud658\uae30\uac00 \ud544\uc694\ud569\ub2c8\ub2e4.<\/p>\n<p><strong>\uc548\uc804<\/strong>: \ub0ae\uc740 DC \uc804\uc555(12V, 24V)\uc740 IEC 61140\uc5d0 \ub530\ub77c \uc548\uc804 \ucd08\uc800\uc804\uc555(SELV)\uc73c\ub85c \ubd84\ub958\ub418\uc5b4 \uc124\uce58, \uc720\uc9c0 \ubcf4\uc218 \ubc0f \ubb38\uc81c \ud574\uacb0 \uc911\uc5d0 \uc778\uc6d0\uc5d0 \ub300\ud55c \uac10\uc804 \uc704\ud5d8\uc744 \ucd5c\uc18c\ud654\ud569\ub2c8\ub2e4. \ub354 \ub192\uc740 AC \uc804\uc555(120V, 230V)\uc5d0\ub294 \ucd94\uac00 \uc548\uc804 \uc608\ubc29 \uc870\uce58\uc640 \uc790\uaca9\uc744 \uac16\ucd98 \uc778\ub825\uc774 \ud544\uc694\ud569\ub2c8\ub2e4.<\/p>\n<p><strong>\uc2e0\ub8b0\uc131 \ubc0f \ub178\uc774\uc988 \ub0b4\uc131<\/strong>: DC \uc81c\uc5b4 \uc804\uc555, \ud2b9\ud788 24V\ub294 \uc804\uae30\uc801\uc73c\ub85c \uc5f4\uc545\ud55c \uc0b0\uc5c5 \ud658\uacbd\uc5d0\uc11c \uc6b0\uc218\ud55c \ub178\uc774\uc988 \ub0b4\uc131\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4. AC \uc804\uc555\uc740 \uc804\uc555 \uac15\ud558 \ud2b9\uc131\uc774 \ub0ae\uae30 \ub54c\ubb38\uc5d0 \ub354 \uae34 \ucf00\uc774\ube14 \uae38\uc774\uc5d0 \uc120\ud638\ub420 \uc218 \uc788\uc2b5\ub2c8\ub2e4.<\/p>\n<h3>DC \ub300 AC \uc81c\uc5b4 \uc804\uc555<\/h3>\n<p>\ud0c0\uc774\uba38 \ub9b4\ub808\uc774\ub294 DC \ubc0f AC \uc81c\uc5b4 \uc804\uc555 \ubaa8\ub450\uc5d0\uc11c \uc0ac\uc6a9\ud560 \uc218 \uc788\uc73c\uba70 \uac01\uac01 \ub69c\ub837\ud55c \uc7a5\uc810\uc774 \uc788\uc2b5\ub2c8\ub2e4.<\/p>\n<table style=\"border-collapse: collapse; width: 100%; margin-bottom: 20px;\" border=\"1\">\n<tbody>\n<tr style=\"background-color: #f5f5f5;\">\n<td style=\"padding: 10px;\"><strong>\ud2b9\uc131<\/strong><\/td>\n<td style=\"padding: 10px;\"><strong>DC \uc81c\uc5b4 (12V, 24V)<\/strong><\/td>\n<td style=\"padding: 10px;\"><strong>AC \uc81c\uc5b4 (120V, 230V)<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px;\"><strong>\uc548\uc804<\/strong><\/td>\n<td style=\"padding: 10px;\">SELV \ubd84\ub958, \ucd5c\uc18c\ud55c\uc758 \uac10\uc804 \uc704\ud5d8<\/td>\n<td style=\"padding: 10px;\">\uc804\uae30 \uc548\uc804 \uc608\ubc29 \uc870\uce58 \ud544\uc694<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px;\"><strong>\ub178\uc774\uc988 \ub0b4\uc131<\/strong><\/td>\n<td style=\"padding: 10px;\">\uc6b0\uc218, EMI\/RFI\uc5d0 \uac15\ud568<\/td>\n<td style=\"padding: 10px;\">\uc804\uae30\uc801 \ub178\uc774\uc988\uc5d0 \ucde8\uc57d<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px;\"><strong>\uc804\uc6d0 \uac00\uc6a9\uc131<\/strong><\/td>\n<td style=\"padding: 10px;\">\uc804\uc6d0 \uacf5\uae09 \uc7a5\uce58 \ud544\uc694; \ucd5c\uc2e0 \uc790\ub3d9\ud654\uc5d0\uc11c \uc77c\ubc18\uc801<\/td>\n<td style=\"padding: 10px;\">\uc8fc\uc804\uc6d0\uc5d0\uc11c \uc9c1\uc811 \uacf5\uae09<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px;\"><strong>\uc77c\ubc18\uc801\uc778 \uc560\ud50c\ub9ac\ucf00\uc774\uc158<\/strong><\/td>\n<td style=\"padding: 10px;\">PLC \uc2dc\uc2a4\ud15c, \uc13c\uc11c, \ucd5c\uc2e0 \uc790\ub3d9\ud654<\/td>\n<td style=\"padding: 10px;\">\uae30\uc874 \uc81c\uc5b4 \ud328\ub110, \uace0\uc804\ub825 \uc2dc\uc2a4\ud15c<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px;\"><strong>\uc804\uc555 \uc548\uc815\uc131<\/strong><\/td>\n<td style=\"padding: 10px;\">\uc870\uc815\ub41c \uc804\uc6d0 \uacf5\uae09 \uc7a5\uce58\uc5d0\uc11c \uc77c\uad00\ub41c \ucd9c\ub825<\/td>\n<td style=\"padding: 10px;\">\uc8fc\uc804\uc6d0 \uc804\uc555 \ubcc0\ub3d9\uc5d0 \uc601\ud5a5 \ubc1b\uc74c<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px;\"><strong>\uac70\ub9ac<\/strong><\/td>\n<td style=\"padding: 10px;\">\uae34 \ucf00\uc774\ube14 \uae38\uc774\uc5d0\uc11c \ub354 \ub192\uc740 \uc804\uc555 \uac15\ud558<\/td>\n<td style=\"padding: 10px;\">\uc7a5\uac70\ub9ac \uc804\uc1a1\uc5d0 \ub354 \uc801\ud569<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>\uc8fc\uc694 \uace0\ub824 \uc0ac\ud56d<\/strong>: \ub9ce\uc740 \ucd5c\uc2e0 VIOX \ud0c0\uc774\uba38 \ub9b4\ub808\uc774\ub294 \ubc94\uc6a9 \uc804\uc555 \uc785\ub825(\uc608: 24-240V AC\/DC)\uc744 \ud2b9\uc9d5\uc73c\ub85c \ud558\uc5ec AC\uc640 DC \uc911\uc5d0\uc11c \uc120\ud0dd\ud560 \ud544\uc694\uac00 \uc5c6\uace0 \uae00\ub85c\ubc8c \ud638\ud658\uc131\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4. \uc774\ub7ec\ud55c \ub2e4\uc911 \uc804\uc555 \ubaa8\ub378\uc740 \uc785\ub825 \uc804\uc555 \uc720\ud615\uc744 \uc790\ub3d9\uc73c\ub85c \uac10\uc9c0\ud558\uace0 \uadf8\uc5d0 \ub530\ub77c \uc791\ub3d9\uc744 \uc870\uc815\ud569\ub2c8\ub2e4.<\/p>\n<figure style=\"text-align: center; margin: 20px 0;\"><img decoding=\"async\" style=\"max-width: 100%; height: auto;\" src=\"https:\/\/img.viox.com\/technical-diagram-comparing-12v-24v-120v-and-230v-timer-relay-system-schematics-with-annotations-showing-key-characteristics-for-each-voltage-type.webp\" alt=\"Technical diagram comparing 12V, 24V, 120V, and 230V timer relay system schematics with annotations showing key characteristics for each voltage type\" \/><figcaption style=\"color: #666; font-style: italic; margin-top: 8px;\">\uadf8\ub9bc 2: 12V, 24V, 120V \ubc0f 230V \ud0c0\uc774\uba38 \ub9b4\ub808\uc774 \ubc30\uc120 \uad6c\uc131 \ubc0f \uc8fc\uc694 \ud2b9\uc131\uc744 \ubcf4\uc5ec\uc8fc\ub294 \uae30\uc220 \ud68c\ub85c\ub3c4 \ube44\uad50.<\/figcaption><\/figure>\n<h2>12V \ub300 24V \ub300 120V \ub300 230V: \uc804\uccb4 \ube44\uad50<\/h2>\n<h3>\uc0c1\uc138 \uc804\uc555 \uc0ac\uc591<\/h3>\n<p>\uac01 \uc81c\uc5b4 \uc804\uc555 \uc635\uc158\uc740 \uc804\ub825 \uc694\uad6c \uc0ac\ud56d, \uc548\uc804 \uc694\uad6c \uc0ac\ud56d \ubc0f \uc2dc\uc2a4\ud15c \uc544\ud0a4\ud14d\ucc98\ub97c \uae30\ubc18\uc73c\ub85c \ub69c\ub837\ud55c \uc560\ud50c\ub9ac\ucf00\uc774\uc158\uc5d0 \uc0ac\uc6a9\ub429\ub2c8\ub2e4.<\/p>\n<table style=\"border-collapse: collapse; width: 100%; margin-bottom: 20px;\" border=\"1\">\n<tbody>\n<tr style=\"background-color: #f5f5f5;\">\n<td style=\"padding: 10px;\"><strong>\uc804\uc555<\/strong><\/td>\n<td style=\"padding: 10px;\"><strong>\uc720\ud615<\/strong><\/td>\n<td style=\"padding: 10px;\"><strong>\uc77c\ubc18\uc801\uc778 \uacf5\ucc28<\/strong><\/td>\n<td style=\"padding: 10px;\"><strong>\uc548\uc804 \ubd84\ub958<\/strong><\/td>\n<td style=\"padding: 10px;\"><strong>\uc8fc\uc694 \uc0ac\uc6a9 \uc0ac\ub840<\/strong><\/td>\n<td style=\"padding: 10px;\"><strong>\uc9c0\ub9ac\uc801 \uc120\ud638\ub3c4<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px;\"><strong>12V \uc9c1\ub958<\/strong><\/td>\n<td style=\"padding: 10px;\">DC<\/td>\n<td style=\"padding: 10px;\">\u00b110-15%<\/td>\n<td style=\"padding: 10px;\">SELV (\uc548\uc804)<\/td>\n<td style=\"padding: 10px;\">\uc790\ub3d9\ucc28, \ubaa8\ubc14\uc77c \uc7a5\ube44, \ubc30\ud130\ub9ac \uc2dc\uc2a4\ud15c<\/td>\n<td style=\"padding: 10px;\">\uae00\ub85c\ubc8c<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px;\"><strong>24V DC<\/strong><\/td>\n<td style=\"padding: 10px;\">DC<\/td>\n<td style=\"padding: 10px;\">\u00b110-20%<\/td>\n<td style=\"padding: 10px;\">SELV (\uc548\uc804)<\/td>\n<td style=\"padding: 10px;\">PLC \uc2dc\uc2a4\ud15c, \uc0b0\uc5c5 \uc790\ub3d9\ud654, \uc13c\uc11c<\/td>\n<td style=\"padding: 10px;\">\uae00\ub85c\ubc8c (\ud45c\uc900)<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px;\"><strong>120V AC<\/strong><\/td>\n<td style=\"padding: 10px;\">AC<\/td>\n<td style=\"padding: 10px;\">\u00b110%<\/td>\n<td style=\"padding: 10px;\">\uc704\ud5d8 \uc804\uc555<\/td>\n<td style=\"padding: 10px;\">\ubd81\ubbf8 \uc81c\uc5b4 \ud328\ub110, \ub808\uac70\uc2dc \uc2dc\uc2a4\ud15c<\/td>\n<td style=\"padding: 10px;\">\ubd81\ubbf8<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px;\"><strong>230V AC<\/strong><\/td>\n<td style=\"padding: 10px;\">AC<\/td>\n<td style=\"padding: 10px;\">\u00b110%<\/td>\n<td style=\"padding: 10px;\">\uc704\ud5d8 \uc804\uc555<\/td>\n<td style=\"padding: 10px;\">\uc720\ub7fd \uae30\uacc4, \uc8fc\uc804\uc6d0 \uc2dc\uc2a4\ud15c<\/td>\n<td style=\"padding: 10px;\">\uc720\ub7fd, \uc544\uc2dc\uc544, \uae00\ub85c\ubc8c<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>12V DC \ud0c0\uc774\uba38 \ub9b4\ub808\uc774<\/h3>\n<ul>\n<li>\uc790\ub3d9\ucc28 \ubc0f \ubaa8\ubc14\uc77c \uc560\ud50c\ub9ac\ucf00\uc774\uc158\uc5d0\uc11c \ub110\ub9ac \uc0ac\uc6a9 \uac00\ub2a5<\/li>\n<li>\ud45c\uc900 12V \ubc30\ud130\ub9ac \uc2dc\uc2a4\ud15c(\ucc28\ub7c9, \ubcf4\ud2b8, RV)\uacfc \ud638\ud658 \uac00\ub2a5<\/li>\n<li>\uc77c\ubc18\uc801\uc778 \uc804\uc555 \uc911\uc5d0\uc11c \uac00\uc7a5 \ub0ae\uc740 \uc804\ub825 \uc18c\ube44<\/li>\n<li>\uc27d\uac8c \uad6c\ud560 \uc218 \uc788\ub294 \uc804\uc6d0 \uacf5\uae09 \uc7a5\uce58<\/li>\n<li>\uc0b0\uc5c5 \uc790\ub3d9\ud654\uc5d0\uc11c \ub35c \uc77c\ubc18\uc801 (24V\uac00 \uc120\ud638\ub428)<\/li>\n<li>24V\uc5d0 \ube44\ud574 \ub3d9\uc77c\ud55c \uc804\ub825\uc5d0 \ub300\ud574 \ub354 \ub192\uc740 \uc804\ub958 \uc18c\ubaa8<\/li>\n<li>\uc0b0\uc5c5\uc6a9 \ub4f1\uae09 \ud0c0\uc774\uba38 \ub9b4\ub808\uc774 \ubaa8\ub378\uc5d0\uc11c \uc81c\ud55c\ub41c \uac00\uc6a9\uc131<\/li>\n<\/ul>\n<p><strong>\uc77c\ubc18\uc801\uc778 \uc751\uc6a9 \ubd84\uc57c:<\/strong><\/p>\n<ul>\n<li>\uc790\ub3d9\ucc28 \uc560\ud504\ud130\ub9c8\ucf13 \uc81c\uc5b4<\/li>\n<li>\ud574\uc591 \ubc0f RV \uc2dc\uc2a4\ud15c<\/li>\n<li>\ud0dc\uc591\uc5f4 \ubc30\ud130\ub9ac \ucda9\uc804 \ucee8\ud2b8\ub864\ub7ec<\/li>\n<li>\ud734\ub300\uc6a9 \uc7a5\ube44 \ubc0f \ubc1c\uc804\uae30<\/li>\n<li>\ub18d\uc5c5\uc6a9 \uc774\ub3d9 \uae30\uacc4<\/li>\n<\/ul>\n<h3>24V DC \ud0c0\uc774\uba38 \ub9b4\ub808\uc774<\/h3>\n<ul>\n<li>\ucd5c\uc2e0 PLC \ubc0f \uc790\ub3d9\ud654 \uc2dc\uc2a4\ud15c\uc758 \uc0b0\uc5c5 \ud45c\uc900<\/li>\n<li>SELV \uc548\uc804 \ub4f1\uae09\uc740 \uc804\uae30\uc801 \uc704\ud5d8\uc744 \uc904\uc785\ub2c8\ub2e4.<\/li>\n<li>\uc0b0\uc5c5 \ud658\uacbd\uc5d0\uc11c \ud0c1\uc6d4\ud55c \ub178\uc774\uc988 \ub0b4\uc131<\/li>\n<li>\ubaa8\ub4e0 \uc8fc\uc694 \uc81c\uc870\uc5c5\uccb4\uc5d0\uc11c \uad11\ubc94\uc704\ud558\uac8c \uc0ac\uc6a9 \uac00\ub2a5<\/li>\n<li>\uc0b0\uc5c5\uc6a9 \uc13c\uc11c, \uc561\ucd94\uc5d0\uc774\ud130 \ubc0f \ud544\ub4dc \uc7a5\uce58\uc640 \ud638\ud658 \uac00\ub2a5<\/li>\n<li>\ub3d9\uc77c\ud55c \uc804\ub825\uc5d0 \ub300\ud574 12V\ubcf4\ub2e4 \ub0ae\uc740 \uc804\ub958 \uc694\uad6c \uc0ac\ud56d<\/li>\n<li>\uc804\uc6a9 24V \uc804\uc6d0 \uacf5\uae09 \uc7a5\uce58 \ud544\uc694 (\uc774\ubbf8 \uc5c6\ub294 \uacbd\uc6b0 \ube44\uc6a9 \ucd94\uac00)<\/li>\n<li>\uae34 \ucf00\uc774\ube14 \uae38\uc774 (&gt;100m)\uc5d0\uc11c \uc804\uc555 \uac15\ud558\uac00 \ud074 \uc218 \uc788\uc74c<\/li>\n<\/ul>\n<p><strong>\uc77c\ubc18\uc801\uc778 \uc751\uc6a9 \ubd84\uc57c:<\/strong><\/p>\n<ul>\n<li>PLC \uc81c\uc5b4 \uc790\ub3d9\ud654 \uc2dc\uc2a4\ud15c<\/li>\n<li>\uacf5\uc7a5 \uc870\ub9bd \ub77c\uc778 \ubc0f \uacf5\uc815 \uc81c\uc5b4<\/li>\n<li>\ube4c\ub529 \uc790\ub3d9\ud654 \ubc0f HVAC \uc81c\uc5b4<\/li>\n<li>\uc548\uc804 \ud68c\ub85c \ubc0f \ube44\uc0c1 \uc815\uc9c0 \uc2dc\uc2a4\ud15c<\/li>\n<li>\uc0b0\uc5c5 \uae30\uacc4 \ubc0f \ub85c\ubd07<\/li>\n<li>\ud3ec\uc7a5 \ubc0f \uc790\uc7ac \ucde8\uae09 \uc7a5\ube44<\/li>\n<\/ul>\n<p><strong>\uc2dc\uc7a5 \uc704\uce58<\/strong>: 24V DC\ub294 \uc804 \uc138\uacc4 \uc2e0\uaddc \uc0b0\uc5c5 \uc124\ube44\uc5d0\uc11c \uc9c0\ubc30\uc801\uc778 \ud45c\uc900\uc785\ub2c8\ub2e4.<\/p>\n<h3>120V AC \ud0c0\uc774\uba38 \ub9b4\ub808\uc774<\/h3>\n<ul>\n<li>\ubd81\ubbf8 \uc8fc\uc804\uc6d0\uc5d0 \uc9c1\uc811 \uc5f0\uacb0 (\uc804\uc6d0 \uacf5\uae09 \uc7a5\uce58 \ubd88\ud544\uc694)<\/li>\n<li>\uace0\uc804\ub825 \uc560\ud50c\ub9ac\ucf00\uc774\uc158\uc5d0 \uc801\ud569<\/li>\n<li>24V DC\uc5d0 \ube44\ud574 \uc7a5\uac70\ub9ac\uc5d0\uc11c \ub0ae\uc740 \uc804\uc555 \uac15\ud558<\/li>\n<li>\uae30\uc874 \uc124\ube44\uc5d0 \uc798 \uad6c\ucd95\ub428<\/li>\n<li>\uc704\ud5d8\ud55c \uc804\uc555\uc73c\ub85c \uc778\ud574 \uc790\uaca9\uc744 \uac16\ucd98 \uc804\uae30 \uae30\uc220\uc790\uac00 \uc124\uce58\ud574\uc57c \ud568<\/li>\n<li>SELV \ub4f1\uae09\uc774 \uc544\ub2d8; \ubb38\uc81c \ud574\uacb0 \uc911 \ub354 \ub192\uc740 \uac10\uc804 \uc704\ud5d8<\/li>\n<li>\ucd5c\uc2e0 PLC \uc2dc\uc2a4\ud15c\uacfc\uc758 \ud638\ud658\uc131\uc774 \ub5a8\uc5b4\uc9d0 (\uc778\ud130\ud398\uc774\uc2a4 \ub9b4\ub808\uc774 \ud544\uc694)<\/li>\n<li>\uc8fc\uc804\uc6d0 \uc804\uc555 \ubcc0\ub3d9\uc5d0 \uc601\ud5a5 \ubc1b\uc74c<\/li>\n<\/ul>\n<p><strong>\uc77c\ubc18\uc801\uc778 \uc751\uc6a9 \ubd84\uc57c:<\/strong><\/p>\n<ul>\n<li>\ubd81\ubbf8 \uc0c1\uc5c5\uc6a9 HVAC \uc2dc\uc2a4\ud15c<\/li>\n<li>\uac74\ubb3c \ub0b4 \uc870\uba85 \uc81c\uc5b4<\/li>\n<li>\uad6c\ud615 \uc0b0\uc5c5 \uc81c\uc5b4 \ud328\ub110<\/li>\n<li>\ud38c\ud504 \ubc0f \ubaa8\ud130 \uc81c\uc5b4<\/li>\n<li>\uac74\ubb3c \uc7a5\ube44 (\ubc30\uae30 \ud32c, \ud788\ud130)<\/li>\n<\/ul>\n<h3>230V AC \ud0c0\uc774\uba38 \ub9b4\ub808\uc774<\/h3>\n<ul>\n<li>\uc720\ub7fd\/\uad6d\uc81c \uc8fc\uc804\uc6d0 (230V\/240V)\uc5d0 \uc9c1\uc811 \uc5f0\uacb0<\/li>\n<li>230V \uc8fc\uc804\uc6d0\uc774 \uc788\ub294 \uc9c0\uc5ed\uc5d0\uc11c\ub294 \uc804\uc6d0 \uacf5\uae09 \uc7a5\uce58\uac00 \ud544\uc694\ud558\uc9c0 \uc54a\uc74c<\/li>\n<li>\uace0\uc804\ub825 \uc7a5\ube44 \uc81c\uc5b4\uc5d0 \ud6a8\uc728\uc801<\/li>\n<li>\uc7a5\uac70\ub9ac \uc81c\uc5b4 \uc2e0\ud638 \uc804\uc1a1\uc5d0 \uc801\ud569<\/li>\n<li>\uc704\ud5d8 \uc804\uc555 \ubd84\ub958<\/li>\n<li>\ud604\uc9c0 \uc804\uae30 \uaddc\uc815\uc744 \uc900\uc218\ud574\uc57c \ud568<\/li>\n<li>\uc800\uc804\uc555 \uc81c\uc5b4 \uc2dc\uc2a4\ud15c\uacfc\uc758 \ud638\ud658\uc131\uc774 \ub5a8\uc5b4\uc9d0<\/li>\n<li>\ub9ce\uc740 \uc9c0\uc5ed\uc5d0\uc11c \uba74\ud5c8\uac00 \uc788\ub294 \uc804\uae30 \uae30\uc220\uc790\ub9cc \uc124\uce58 \uac00\ub2a5<\/li>\n<\/ul>\n<p><strong>\uc77c\ubc18\uc801\uc778 \uc751\uc6a9 \ubd84\uc57c:<\/strong><\/p>\n<ul>\n<li>\uc720\ub7fd \uc0b0\uc5c5 \uae30\uacc4<\/li>\n<li>\uad6d\uc81c \uc0c1\uc5c5 \uc7a5\ube44<\/li>\n<li>\uace0\uc804\ub825 \ubaa8\ud130 \uc81c\uc5b4<\/li>\n<li>230V \uc9c0\uc5ed\uc758 HVAC \uc2dc\uc2a4\ud15c<\/li>\n<li>\uac74\ubb3c \uc11c\ube44\uc2a4 (\ud38c\ud504, \uc555\ucd95\uae30, \ud658\uae30)<\/li>\n<\/ul>\n<h3>\ubc94\uc6a9 \uc804\uc555 \ud0c0\uc774\uba38 \ub9b4\ub808\uc774 (24-240V AC\/DC)<\/h3>\n<p>\ucd5c\uc2e0 VIOX \ud0c0\uc774\uba38 \ub9b4\ub808\uc774\ub294 \uc810\uc810 \ub354 \ub113\uc740 \ubc94\uc704\ub97c \uc218\uc6a9\ud558\ub294 \ubc94\uc6a9 \uc804\uc555 \uc785\ub825\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4.<\/p>\n<ul>\n<li>\ub2e8\uc77c \ubaa8\ub378\ub85c \uae00\ub85c\ubc8c \uc2dc\uc7a5\uc5d0 \uc11c\ube44\uc2a4 \uc81c\uacf5<\/li>\n<li>\uac04\uc18c\ud654\ub41c \uc7ac\uace0 \ubc0f \uc870\ub2ec<\/li>\n<li>\ub2e4\uc591\ud55c \uc804\uc555 \uc2dc\uc2a4\ud15c\uc5d0\uc11c \uc720\uc5f0\ud55c \uc124\uce58<\/li>\n<li>\uc2dc\uc124 \uc804\uc555 \ubcc0\uacbd\uc5d0 \ub300\ud55c \ubbf8\ub798 \ubcf4\uc7a5<\/li>\n<li>\uc5d4\uc9c0\ub2c8\uc5b4\ub9c1 \uc0ac\uc591 \ubcf5\uc7a1\uc131 \uac10\uc18c<\/li>\n<\/ul>\n<p><strong>\uace0\ub824 \uc0ac\ud56d:<\/strong><\/p>\n<ul>\n<li>\uc77c\ubc18\uc801\uc73c\ub85c \ub2e8\uc77c \uc804\uc555 \ubaa8\ub378\ubcf4\ub2e4 10-20% \ub192\uc740 \ube44\uc6a9<\/li>\n<li>\uc2e4\uc81c \uc804\uc555 \ubc94\uc704\uac00 \uc694\uad6c \uc0ac\ud56d\uc744 \ucda9\uc871\ud558\ub294\uc9c0 \ud655\uc778\ud558\uc2ed\uc2dc\uc624.<\/li>\n<\/ul>\n<figure style=\"text-align: center; margin: 20px 0;\"><img decoding=\"async\" style=\"max-width: 100%; height: auto;\" src=\"https:\/\/img.viox.com\/electrical-circuit-schematic-showing-timer-relay-wiring-connections-for-dc-control-circuits-and-ac-control-circuits-with-labeled-terminals.webp\" alt=\"Electrical circuit schematic showing timer relay wiring connections for DC control circuits and AC control circuits with labeled terminals\" \/><figcaption style=\"color: #666; font-style: italic; margin-top: 8px;\">\uadf8\ub9bc 3: DC \ubc0f AC \uc81c\uc5b4 \ud68c\ub85c \ubaa8\ub450\uc5d0 \ub300\ud55c \uc62c\ubc14\ub978 \ubc30\uc120 \uc5f0\uacb0\uc744 \ubcf4\uc5ec\uc8fc\ub294 \uc0c1\uc138 \ud68c\ub85c\ub3c4 (\ub2e8\uc790 \ub808\uc774\ube14 \ud3ec\ud568).<\/figcaption><\/figure>\n<h2>\uc560\ud50c\ub9ac\ucf00\uc774\uc158 \uc720\ud615\ubcc4 \uc120\ud0dd \uae30\uc900<\/h2>\n<h3>\uc758\uc0ac \uacb0\uc815 \ud504\ub808\uc784\uc6cc\ud06c<\/h3>\n<p>\ucd5c\uc801\uc758 \ud0c0\uc774\uba38 \ub9b4\ub808\uc774 \uc81c\uc5b4 \uc804\uc555\uc744 \uc120\ud0dd\ud558\ub824\uba74 \uc774 \uccb4\uacc4\uc801\uc778 \uc811\uadfc \ubc29\uc2dd\uc744 \uc0ac\uc6a9\ud558\uc2ed\uc2dc\uc624.<\/p>\n<table style=\"border-collapse: collapse; width: 100%; margin-bottom: 20px;\" border=\"1\">\n<tbody>\n<tr style=\"background-color: #f5f5f5;\">\n<td style=\"padding: 10px;\"><strong>\uc6b0\uc120\uc21c\uc704 \uc694\uc18c<\/strong><\/td>\n<td style=\"padding: 10px;\"><strong>\uad8c\uc7a5 \uc804\uc555<\/strong><\/td>\n<td style=\"padding: 10px;\"><strong>\ucd94\ub860<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px;\"><strong>\uae30\uc874 PLC\/\uc81c\uc5b4 \uc2dc\uc2a4\ud15c<\/strong><\/td>\n<td style=\"padding: 10px;\">\uc2dc\uc2a4\ud15c \uc804\uc555 \uc77c\uce58<\/td>\n<td style=\"padding: 10px;\">\uc9c1\uc811\uc801\uc778 \ud638\ud658\uc131 \ubcf4\uc7a5; \ub300\ubd80\ubd84\uc758 \ucd5c\uc2e0 PLC\uc758 \uacbd\uc6b0 24V DC<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px;\"><strong>\uc548\uc804\uc774 \uc911\uc694\ud55c \uc560\ud50c\ub9ac\ucf00\uc774\uc158<\/strong><\/td>\n<td style=\"padding: 10px;\">12V \ub610\ub294 24V DC (SELV)<\/td>\n<td style=\"padding: 10px;\">\uc720\uc9c0 \ubcf4\uc218 \ubc0f \ubb38\uc81c \ud574\uacb0 \uc911 \uac10\uc804 \uc704\ud5d8 \ucd5c\uc18c\ud654<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px;\"><strong>\ubaa8\ubc14\uc77c\/\ubc30\ud130\ub9ac \uc804\uc6d0<\/strong><\/td>\n<td style=\"padding: 10px;\">12V \uc9c1\ub958<\/td>\n<td style=\"padding: 10px;\">\ud45c\uc900 \uc790\ub3d9\ucc28\/\ud574\uc591 \ubc30\ud130\ub9ac \uc804\uc555<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px;\"><strong>\uae30\uc874 \uc81c\uc5b4 \uc2dc\uc2a4\ud15c \uc5c6\uc74c<\/strong><\/td>\n<td style=\"padding: 10px;\">24V DC (\ubbf8\ub798 \ub300\ube44)<\/td>\n<td style=\"padding: 10px;\">\uc0b0\uc5c5 \ud45c\uc900, \ud655\uc7a5\uc131\uc744 \uc704\ud55c \ucd5c\ub300 \uc720\uc5f0\uc131<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px;\"><strong>\uae30\uc874 AC \uc2dc\uc2a4\ud15c\uc73c\ub85c \uac1c\uc870<\/strong><\/td>\n<td style=\"padding: 10px;\">\uae30\uc874 (120V \ub610\ub294 230V)\uacfc \uc77c\uce58<\/td>\n<td style=\"padding: 10px;\">\uc124\uce58 \ube44\uc6a9 \ubc0f \ubcf5\uc7a1\uc131 \ucd5c\uc18c\ud654<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px;\"><strong>\uae00\ub85c\ubc8c \uc7a5\ube44<\/strong><\/td>\n<td style=\"padding: 10px;\">\ubc94\uc6a9 24-240V AC\/DC<\/td>\n<td style=\"padding: 10px;\">\uc804 \uc138\uacc4 \ubc30\ud3ec\ub97c \uc704\ud55c \ub2e8\uc77c \uc0ac\uc591<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px;\"><strong>\uae34 \ucf00\uc774\ube14 \uae38\uc774 (&gt;100m)<\/strong><\/td>\n<td style=\"padding: 10px;\">120V \ub610\ub294 230V AC<\/td>\n<td style=\"padding: 10px;\">\uac70\ub9ac \ub300\ube44 \ub0ae\uc740 \uc804\uc555 \uac15\ud558<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px;\"><strong>\ub178\uc774\uc988\uac00 \uc2ec\ud55c \uc804\uae30 \ud658\uacbd<\/strong><\/td>\n<td style=\"padding: 10px;\">24V DC<\/td>\n<td style=\"padding: 10px;\">\uc6b0\uc218\ud55c EMI\/RFI \ub0b4\uc131<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>\uc560\ud50c\ub9ac\ucf00\uc774\uc158\ubcc4 \uad8c\uc7a5 \uc0ac\ud56d<\/h3>\n<h4>\uc0b0\uc5c5 \uc790\ub3d9\ud654 \ubc0f \uc81c\uc870<\/h4>\n<p><strong>\uad8c\uc7a5: 24V DC<\/strong><\/p>\n<ul>\n<li>PLC \uc785\/\ucd9c\ub825 \ubaa8\ub4c8<\/li>\n<li>\uc0b0\uc5c5\uc6a9 \uc13c\uc11c (\uadfc\uc811, \uad11\uc804, \uc555\ub825)<\/li>\n<li>\uacf5\uc555 \ubc38\ube0c \uc194\ub808\ub178\uc774\ub4dc<\/li>\n<li>\ud328\ub110 \ud45c\uc2dc\uae30 \ubc0f \ud478\uc2dc \ubc84\ud2bc<\/li>\n<li>\uc548\uc804 \ub9b4\ub808\uc774 \ubc0f \ube44\uc0c1 \uc815\uc9c0 \ud68c\ub85c<\/li>\n<li><strong>120V\/230V AC<\/strong>: \ub808\uac70\uc2dc \uc7a5\ube44 \ub610\ub294 PLC \uc81c\uc5b4 \uc5c6\uc774 \ub3c5\ub9bd\ud615 \ubaa8\ud130 \uae30\ub3d9\uae30<\/li>\n<li><strong>\ubc94\uc6a9 \uc804\uc555<\/strong>: \uc5ec\ub7ec \uae00\ub85c\ubc8c \uc2dc\uc124\uc5d0 \uacf5\uae09\ub418\ub294 \uc7a5\ube44<\/li>\n<\/ul>\n<h4>\ube4c\ub529 \uc790\ub3d9\ud654 \ubc0f HVAC<\/h4>\n<p><strong>\uad8c\uc7a5: 24V AC \ub610\ub294 24V DC<\/strong><\/p>\n<p>\ube4c\ub529 \uad00\ub9ac \uc2dc\uc2a4\ud15c\uc740 \uc77c\ubc18\uc801\uc73c\ub85c 24V AC (\ubd81\ubbf8) \ub610\ub294 24V DC (\uc720\ub7fd)\uc5d0\uc11c \uc791\ub3d9\ud569\ub2c8\ub2e4. \ud0c0\uc774\uba38 \ub9b4\ub808\uc774\ub294 \ud32c \uc9c0\uc5f0 \uaebc\uc9d0, \uc555\ucd95\uae30 \uc2dc\uac04 \uc9c0\uc5f0, \ud658\uae30 \ud37c\uc9c0 \uc8fc\uae30 \ubc0f \uc870\uba85 \uc2dc\ud000\uc2a4\ub97c \uc81c\uc5b4\ud569\ub2c8\ub2e4.<\/p>\n<ul>\n<li><strong>120V\/230V AC<\/strong>: \uc811\ucd09\uae30 \uc5c6\uc774 \ub77c\uc778 \uc804\uc555 \uc7a5\ube44\ub97c \uc9c1\uc811 \uc81c\uc5b4<\/li>\n<li><strong>12V \uc9c1\ub958<\/strong>: \ube44\uc0c1 \uc791\ub3d9\uc744 \uc704\ud55c \ubc30\ud130\ub9ac \ubc31\uc5c5 \uc2dc\uc2a4\ud15c<\/li>\n<\/ul>\n<h4>\ubaa8\ud130 \uc81c\uc5b4 \ubc0f \uc804\ub825 \ubd84\ubc30<\/h4>\n<p><strong>\uad8c\uc7a5: \ubaa8\ud130 \ud06c\uae30 \ubc0f \uc81c\uc5b4 \uc544\ud0a4\ud14d\ucc98\uc5d0 \ub530\ub77c \ub2e4\ub984<\/strong><\/p>\n<table style=\"border-collapse: collapse; width: 100%; margin-bottom: 20px;\" border=\"1\">\n<tbody>\n<tr style=\"background-color: #f5f5f5;\">\n<td style=\"padding: 10px;\"><strong>\ubaa8\ud130 \uc560\ud50c\ub9ac\ucf00\uc774\uc158<\/strong><\/td>\n<td style=\"padding: 10px;\"><strong>\uc81c\uc5b4 \uc804\uc555<\/strong><\/td>\n<td style=\"padding: 10px;\"><strong>\uc77c\ubc18\uc801\uc778 \uc0ac\uc6a9 \uc0ac\ub840<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px;\"><strong>\uae30\ub3d9\uae30\uac00 \uc788\ub294 \uc18c\ud615 \ubaa8\ud130 (&lt;2 HP)<\/strong><\/td>\n<td style=\"padding: 10px;\">24V DC<\/td>\n<td style=\"padding: 10px;\">PLC \uc81c\uc5b4 \ucee8\ubca0\uc774\uc5b4, \ud38c\ud504 \uc2dc\ud000\uc2f1<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px;\"><strong>\uc911\uac04 \ubaa8\ud130 (2-50 HP)<\/strong><\/td>\n<td style=\"padding: 10px;\">120V AC<\/td>\n<td style=\"padding: 10px;\">\ubd81\ubbf8 \uc9c0\uc5ed\uc758 \uc811\ucd09\uae30 \ucf54\uc77c \uc81c\uc5b4<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px;\"><strong>\ub300\ud615 \ubaa8\ud130 (&gt;50 HP)<\/strong><\/td>\n<td style=\"padding: 10px;\">230V AC<\/td>\n<td style=\"padding: 10px;\">\uace0\uc804\ub825 \uc0b0\uc5c5 \uc7a5\ube44<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px;\"><strong>\uc2a4\ud0c0 \ub378\ud0c0 \uc2a4\ud0c0\ud130<\/strong><\/td>\n<td style=\"padding: 10px;\">24V DC \ub610\ub294 120V<\/td>\n<td style=\"padding: 10px;\">\uc2a4\ud0c0 \ubc0f \ub378\ud0c0 \uad8c\uc120 \uac04\uc758 \ud0c0\uc774\ubc0d \uc804\ud658<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h4>\ub18d\uc5c5 \ubc0f \ubaa8\ubc14\uc77c \uc7a5\ube44<\/h4>\n<p><strong>\uad8c\uc7a5: 12V DC<\/strong><\/p>\n<p>\ud2b8\ub799\ud130, \uad00\uac1c \uc2dc\uc2a4\ud15c \ubc0f \ubaa8\ubc14\uc77c \uae30\uacc4\ub294 12V \ubc30\ud130\ub9ac \uc2dc\uc2a4\ud15c\uc744 \uc0ac\uc6a9\ud569\ub2c8\ub2e4. \ud0c0\uc774\uba38 \ub9b4\ub808\uc774\ub294 \uad00\uac1c \uad6c\uc5ed \ud0c0\uc774\ubc0d, \uc7a5\ube44 \uc2dc\uc791 \uc9c0\uc5f0 \ubc0f \ubcf4\uc870 \uc2dc\uc2a4\ud15c \ud0c0\uc774\ubc0d (\uc870\uba85, \ud788\ud130, \uc1a1\ud48d\uae30)\uc744 \uc81c\uc5b4\ud569\ub2c8\ub2e4.<\/p>\n<ul>\n<li><strong>24V DC<\/strong>: 24V \uc2dc\uc2a4\ud15c\uc744 \uac16\ucd98 \ub300\ud615 \uc0c1\uc5c5\uc6a9 \ub18d\uc5c5 \uc7a5\ube44<\/li>\n<li><strong>230V AC<\/strong>: \uc8fc\uc804\uc6d0 \uacf5\uae09 \uc7a5\uce58\uac00 \uc788\ub294 \uace0\uc815 \uc7a5\ube44 (\ud3ec\uc7a5 \ucc3d\uace0, \ubcf4\uad00 \uc2dc\uc124)<\/li>\n<\/ul>\n<h4>\uc548\uc804 \ubc0f \ube44\uc0c1 \uc2dc\uc2a4\ud15c<\/h4>\n<p><strong>\uad8c\uc7a5: 24V DC (\ubc30\ud130\ub9ac \ubc31\uc5c5 \ud3ec\ud568)<\/strong><\/p>\n<p>\uc548\uc804 \ud68c\ub85c\ub294 \ube44\uc0c1 \uc870\uba85, \ub300\ud53c \uc2dc\uc2a4\ud15c, \ud654\uc7ac \uc9c4\uc555 \ubc0f \uc548\uc804 \uc778\ud130\ub85d\uc744 \uc704\ud574 \ubb34\uc815\uc804 \uc804\uc6d0 \uacf5\uae09 \uc7a5\uce58\uac00 \uc788\ub294 SELV \uc804\uc555\uc744 \uc0ac\uc6a9\ud574\uc57c \ud569\ub2c8\ub2e4 (ISO 13849\uc5d0 \ub530\ub984).<\/p>\n<p><strong>\uc911\uc694 \uc694\uad6c \uc0ac\ud56d<\/strong>: \uc548\uc804 \uad00\ub828 \ud0c0\uc774\uba38 \ub9b4\ub808\uc774\ub294 \ud574\ub2f9 \uae30\ub2a5 \uc548\uc804 \ud45c\uc900 (IEC 61508\uc5d0 \ub530\ub978 SIL \ub4f1\uae09 \ub610\ub294 ISO 13849\uc5d0 \ub530\ub978 \uc131\ub2a5 \uc218\uc900)\uc744 \ucda9\uc871\ud574\uc57c \ud569\ub2c8\ub2e4.<\/p>\n<h2>Standards and Compliance<\/h2>\n<p>\ud0c0\uc774\uba38 \ub9b4\ub808\uc774 \uc81c\uc5b4 \uc804\uc555 \uc120\ud0dd\uc740 \uc548\uc804, \uc131\ub2a5 \ubc0f \ubc95\uc801 \uc900\uc218\ub97c \ubcf4\uc7a5\ud558\uae30 \uc704\ud574 \ud574\ub2f9 \uad6d\uc81c \ubc0f \uc9c0\uc5ed \ud45c\uc900\uc744 \uc900\uc218\ud574\uc57c \ud569\ub2c8\ub2e4.<\/p>\n<h3>\uc8fc\uc694 \uad6d\uc81c \ud45c\uc900<\/h3>\n<table style=\"border-collapse: collapse; width: 100%; margin-bottom: 20px;\" border=\"1\">\n<tbody>\n<tr style=\"background-color: #f5f5f5;\">\n<td style=\"padding: 10px;\"><strong>\uc900<\/strong><\/td>\n<td style=\"padding: 10px;\"><strong>\ubc94\uc704<\/strong><\/td>\n<td style=\"padding: 10px;\"><strong>\uc804\uc555 \uc120\ud0dd\uacfc\uc758 \uad00\ub828\uc131<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px;\"><strong>IEC61812-1<\/strong><\/td>\n<td style=\"padding: 10px;\">\uc0b0\uc5c5\uc6a9 \uc2dc\uac04 \ub9b4\ub808\uc774<\/td>\n<td style=\"padding: 10px;\">\uc804\uae30\uc801 \uc2a4\ud2b8\ub808\uc2a4 \ud558\uc5d0\uc11c \uc131\ub2a5 \uc694\uad6c \uc0ac\ud56d, \uc815\ud655\uc131 \ubc0f \uc548\uc804\uc744 \uc815\uc758\ud569\ub2c8\ub2e4.<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px;\"><strong>IEC 60255<\/strong><\/td>\n<td style=\"padding: 10px;\">\uce21\uc815 \ub9b4\ub808\uc774 \ubc0f \ubcf4\ud638<\/td>\n<td style=\"padding: 10px;\">\ub9b4\ub808\uc774 \uad6c\uc131 \ubc0f \ud14c\uc2a4\ud2b8 \ubc29\ubc95\uc744 \ub2e4\ub8f9\ub2c8\ub2e4.<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px;\"><strong>IEC 61140<\/strong><\/td>\n<td style=\"padding: 10px;\">\uc5d0 \ub300\ud55c \ubcf4\ud638\ub97c \uc804\uae30\uc801 \ucda9\uaca9<\/td>\n<td style=\"padding: 10px;\">SELV (\u226450V AC\/\u2264120V DC) \uc548\uc804 \ubd84\ub958\ub97c \uc815\uc758\ud569\ub2c8\ub2e4.<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px;\"><strong>IEC 60664-1<\/strong><\/td>\n<td style=\"padding: 10px;\">\uc808\uc5f0 \ud611\uc870<\/td>\n<td style=\"padding: 10px;\">\uc804\uc555\ubcc4\ub85c \uac04\uaca9 \ubc0f \uc5f0\uba74 \uac70\ub9ac\ub97c \uc9c0\uc815\ud569\ub2c8\ub2e4.<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px;\"><strong>UL508<\/strong><\/td>\n<td style=\"padding: 10px;\">\uc0b0\uc5c5 \uc81c\uc5b4 \uc7a5\ube44 (\ubd81\ubbf8)<\/td>\n<td style=\"padding: 10px;\">\ud0c0\uc774\uba38 \ub9b4\ub808\uc774\ub97c \ud3ec\ud568\ud55c \uc81c\uc5b4 \uc7a5\uce58 \uc548\uc804 \ud45c\uc900<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px;\"><strong>IEC\/UL 61810-1<\/strong><\/td>\n<td style=\"padding: 10px;\">\uc804\uae30\uae30\uacc4 \uae30\ubcf8 \ub9b4\ub808\uc774<\/td>\n<td style=\"padding: 10px;\">\ub9b4\ub808\uc774\uc5d0 \ub300\ud55c UL 508\uc744 \ub300\uccb4\ud558\ub294 \uc870\ud654 \ud45c\uc900<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>\uc548\uc804 \ub4f1\uae09<\/h3>\n<ul>\n<li>12V \ubc0f 24V DC \uc2dc\uc2a4\ud15c\uc5d0 \uc801\uc6a9<\/li>\n<li>IEC 61140\uc740 SELV\ub97c \u226450V AC \ub610\ub294 \u2264120V DC\ub85c \uc815\uc758<\/li>\n<li>\ucd5c\uc18c\ud55c\uc758 \uac10\uc804 \uc704\ud5d8<\/li>\n<li>\ud2b9\uc815 \uc870\uac74 \ud558\uc5d0\uc11c \ube44\uc808\uc5f0 \uc811\ucd09 \uac00\ub2a5 \ubd80\ud488 \ud5c8\uc6a9<\/li>\n<li>\uc791\uc5c5\uc790\uac00 \uc811\uadfc \uac00\ub2a5\ud55c \uc81c\uc5b4 \ud68c\ub85c\uc5d0 \uc120\ud638<\/li>\n<li>\uc804\uae30\uc801 \uc808\uc5f0 \ubc0f \ubcf4\ud638 \uc7a5\ubcbd \ud544\uc694<\/li>\n<li>\ub300\ubd80\ubd84\uc758 \uad00\ud560 \uad6c\uc5ed\uc5d0\uc11c \uc790\uaca9\uc744 \uac16\ucd98 \uc804\uae30 \uae30\uc220\uc790\uc758 \uc124\uce58 \uc758\ubb34\ud654<\/li>\n<li>\ucd94\uac00 \uc548\uc804 \ubb38\uc11c \ubc0f \ub77c\ubca8\ub9c1 \ud544\uc694<\/li>\n<li>\ud604\uc9c0 \uc804\uae30 \uaddc\uc815 (NEC, IEC 60364 \ub4f1) \uc900\uc218 \ud544\uc218<\/li>\n<\/ul>\n<h3>\uc9c0\uc5ed\ubcc4 \uc900\uc218 \uace0\ub824 \uc0ac\ud56d<\/h3>\n<ul>\n<li>\uc77c\ubc18\uc801\uc73c\ub85c \uc0c1\uc5c5\uc6a9 \uc124\uce58\uc5d0\ub294 UL \ub610\ub294 CSA \uc778\uc99d \ud544\uc694<\/li>\n<li>NEC (National Electrical Code)\ub294 \uc124\uce58 \uad00\ud589\uc744 \uaddc\uc815<\/li>\n<li>120V AC\ub294 \ub808\uac70\uc2dc \uc2dc\uc2a4\ud15c\uc758 \ud45c\uc900 \uc81c\uc5b4 \uc804\uc555<\/li>\n<li>\uc0c8\ub85c\uc6b4 \uc790\ub3d9\ud654 \ud504\ub85c\uc81d\ud2b8\uc5d0\uc11c 24V DC\ub85c \uc804\ud658<\/li>\n<li>CE \ub9c8\ud0b9 \ud544\uc218 (\uc800\uc804\uc555 \uc9c0\uce68, EMC \uc9c0\uce68 \uc900\uc218)<\/li>\n<li>IEC 61812-1\uc740 \uc8fc\uc694 \uae30\ub2a5 \ud45c\uc900<\/li>\n<li>\uc8fc\uc804\uc6d0\uc5d0\uc11c \ud30c\uc0dd\ub41c \uc81c\uc5b4\uc5d0 \ub300\ud55c 230V AC \ud45c\uc900<\/li>\n<li>\uc790\ub3d9\ud654 \ubc0f PLC \uc2dc\uc2a4\ud15c\uc5d0 \ub300\ud55c 24V DC \ud45c\uc900<\/li>\n<li>\ub2e4\uc591\ud55c \uc694\uad6c \uc0ac\ud56d; IEC \ud45c\uc900\uc774 \ub110\ub9ac \uc778\uc815\ub428<\/li>\n<li>\ub9ce\uc740 \uc9c0\uc5ed\uc5d0\uc11c UL \ub610\ub294 CE \uc778\uc99d\uc744 \ud5c8\uc6a9<\/li>\n<li>\uc804\uc555 \ud45c\uc900\ud654\ub294 \uad6d\uac00\ubcc4\ub85c \ub2e4\ub984 (230V\uac00 \uc9c0\ubc30\uc801\uc774\uba70 \uc77c\ubd80 220V\/240V)<\/li>\n<\/ul>\n<h2>\uc2e4\uc6a9\uc801\uc778 \uc120\ud0dd \uc9c0\uce68<\/h2>\n<h3>\ube60\ub978 \uc120\ud0dd \uc758\uc0ac \uacb0\uc815 \ud2b8\ub9ac<\/h3>\n<p><strong>\uc2dc\uc791: \uae30\uc874 \uc81c\uc5b4 \uc2dc\uc2a4\ud15c\uc774 \uc788\uc2b5\ub2c8\uae4c?<\/strong><\/p>\n<p>\u2192 <strong>\uc608<\/strong>: PLC, DCS \ub610\ub294 \uc81c\uc5b4 \ud328\ub110\uc758 \uc81c\uc5b4 \uc804\uc555\uacfc \uc77c\uce58<\/p>\n<ul>\n<li>PLC \uc2dc\uc2a4\ud15c \u2192 \uc77c\ubc18\uc801\uc73c\ub85c 24V DC<\/li>\n<li>\uad6c\ud615 \ub9b4\ub808\uc774 \ud328\ub110 \u2192 120V AC (\ubd81\ubbf8) \ub610\ub294 230V AC (\uc720\ub7fd)<\/li>\n<li>\ube4c\ub529 \uc790\ub3d9\ud654 \u2192 24V AC\/DC<\/li>\n<li>\ubaa8\ubc14\uc77c \uc7a5\ube44 \u2192 12V DC<\/li>\n<\/ul>\n<figure style=\"text-align: center; margin: 20px 0;\"><img decoding=\"async\" style=\"max-width: 100%; height: auto;\" src=\"https:\/\/img.viox.com\/decision-flowchart-infographic-for-timer-relay-voltage-selection-showing-application-paths-from-requirements-to-12v-24v-120v-or-230v-recommendations.webp\" alt=\"Decision flowchart infographic for timer relay voltage selection showing application paths from requirements to 12V, 24V, 120V, or 230V recommendations\" \/><figcaption style=\"color: #666; font-style: italic; margin-top: 8px;\">\uadf8\ub9bc 4: \ud0c0\uc774\uba38 \ub9b4\ub808\uc774 \uc804\uc555 \uc120\ud0dd \uac00\uc774\ub4dc \u2013 \uc560\ud50c\ub9ac\ucf00\uc774\uc158 \uc694\uad6c \uc0ac\ud56d\uc5d0\uc11c \uc804\uc555 \uad8c\uc7a5 \uc0ac\ud56d\uae4c\uc9c0\uc758 \ud3ec\uad04\uc801\uc778 \ud750\ub984\ub3c4.<\/figcaption><\/figure>\n<p>\u2192 <strong>\uc544\ub2c8\uc694<\/strong> (\uc0c8\ub85c\uc6b4 \uc124\uacc4): \uc120\ud0dd <strong>24V DC<\/strong><\/p>\n<ul>\n<li>\uc0b0\uc5c5 \ud45c\uc900, \ucd5c\ub300 \uc720\uc5f0\uc131<\/li>\n<li>\ucd5c\uace0\uc758 \uc548\uc804 \ud504\ub85c\ud544 (SELV)<\/li>\n<li>\uac00\uc7a5 \uad11\ubc94\uc704\ud55c \uc81c\ud488 \uac00\uc6a9\uc131<\/li>\n<li>\ud5a5\ud6c4 \ud655\uc7a5 \ud638\ud658\uc131<\/li>\n<\/ul>\n<p><strong>\uc608\uc678<\/strong>: \uc81c\uc5b4 \uc2dc\uc2a4\ud15c \uc778\ud504\ub77c\uac00 \uc5c6\ub294 \uc8fc\uc804\uc6d0 \uad6c\ub3d9 \uc7a5\ube44\uc758 \uacbd\uc6b0 \uc804\uc6d0 \uacf5\uae09 \uc7a5\uce58 \ube44\uc6a9\uc744 \uc5c6\uc560\uae30 \uc704\ud574 120V\/230V AC (\uc9c0\uc5ed\ubcc4)\ub97c \uc0ac\uc6a9\ud558\uc2ed\uc2dc\uc624.<\/p>\n<h3>\uc124\uce58 \uace0\ub824 \uc0ac\ud56d<\/h3>\n<table style=\"border-collapse: collapse; width: 100%; margin-bottom: 20px;\" border=\"1\">\n<tbody>\n<tr style=\"background-color: #f5f5f5;\">\n<td style=\"padding: 10px;\"><strong>\uc728<\/strong><\/td>\n<td style=\"padding: 10px;\"><strong>12V\/24V DC<\/strong><\/td>\n<td style=\"padding: 10px;\"><strong>120V\/230V AC<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px;\"><strong>\uc804\uc6d0 \uacf5\uae09 \uc7a5\uce58 \ud544\uc694<\/strong><\/td>\n<td style=\"padding: 10px;\">\uc608 ($50-200 \ucd94\uac00)<\/td>\n<td style=\"padding: 10px;\">\uc544\ub2c8\uc694 (\uc8fc\uc804\uc6d0\uc5d0\uc11c \uc9c1\uc811)<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px;\"><strong>\ubc30\uc120<\/strong><\/td>\n<td style=\"padding: 10px;\">\ub354 \uc791\uc740 \uac8c\uc774\uc9c0 \ud5c8\uc6a9<\/td>\n<td style=\"padding: 10px;\">\ub354 \ud070 \uac8c\uc774\uc9c0, \uc804\uc120\uad00\uc774 \uc885\uc885 \ud544\uc694<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px;\"><strong>\uc124\uce58 \uc778\ub825<\/strong><\/td>\n<td style=\"padding: 10px;\">\ub0ae\uc740 \uae30\uc220 \uc218\uc900 \ud5c8\uc6a9<\/td>\n<td style=\"padding: 10px;\">\uc77c\ubc18\uc801\uc73c\ub85c \uba74\ud5c8\uac00 \uc788\ub294 \uc804\uae30 \uae30\uc220\uc790 \ud544\uc694<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px;\"><strong>\ubb38\uc81c \ud574\uacb0<\/strong><\/td>\n<td style=\"padding: 10px;\">\uae30\ubcf8 \uad50\uc721\uc744 \ubc1b\uc740 \uae30\uc220\uc790\uc5d0\uac8c \uc548\uc804<\/td>\n<td style=\"padding: 10px;\">\uc804\uae30 \uc548\uc804 \uc608\ubc29 \uc870\uce58 \ud544\uc694<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px;\"><strong>\uc804\uc555 \uac15\ud558 \ubb38\uc81c<\/strong><\/td>\n<td style=\"padding: 10px;\">&gt;100m \uc774\uc0c1\uc5d0\uc11c \uc0c1\ub2f9\ud568<\/td>\n<td style=\"padding: 10px;\">\ucd5c\uc18c<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px;\"><strong>EMI \uac10\uc218\uc131<\/strong><\/td>\n<td style=\"padding: 10px;\">DC\uac00 \ub354 \uba74\uc5ed\ub428 (\ud2b9\ud788 24V)<\/td>\n<td style=\"padding: 10px;\">AC\ub294 \ub178\uc774\uc988\uc5d0 \ucde8\uc57d\ud568<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>\ube44\uc6a9 \ud3b8\uc775 \ubd84\uc11d<\/h3>\n<ul>\n<li><strong>12V\/24V DC<\/strong>: \ub9b4\ub808\uc774 + \uc804\uc6d0 \uacf5\uae09 \uc7a5\uce58 ($50-200) = \ub354 \ub192\uc740 \ucd08\uae30 \ube44\uc6a9<\/li>\n<li><strong>120V\/230V AC<\/strong>: \ub9b4\ub808\uc774\ub9cc = \ub354 \ub0ae\uc740 \ucd08\uae30 \ube44\uc6a9<\/li>\n<li><strong>24V DC<\/strong>: \ub354 \ub0ae\uc740 \uc720\uc9c0 \ubcf4\uc218 (\ub354 \uc548\uc804\ud55c \ubb38\uc81c \ud574\uacb0), \ub354 \uc26c\uc6b4 \ud655\uc7a5, \uc2dc\ub044\ub7ec\uc6b4 \ud658\uacbd\uc5d0\uc11c \ub354 \ub098\uc740 \uc548\uc815\uc131<\/li>\n<li><strong>120V\/230V AC<\/strong>: \uc804\uc555 \ubcc0\ub3d9\uc73c\ub85c \uc778\ud55c \uc624\uc791\ub3d9 \uc704\ud5d8 \uc99d\uac00, \uc218\uc815\uc744 \uc704\ud574 \uc804\uae30 \uae30\uc220\uc790 \ud544\uc694<\/li>\n<\/ul>\n<p><strong>VIOX \uad8c\uc7a5 \uc0ac\ud56d<\/strong>: \uc0c8\ub85c\uc6b4 \uc0b0\uc5c5 \uc124\ube44\uc758 \uacbd\uc6b0 24V DC \uc2dc\uc2a4\ud15c\uc758 \uc7a5\uae30\uc801\uc778 \uc774\uc810\uc774 \uc57d\uac04\uc758 \ucd94\uac00 \ucd08\uae30 \ube44\uc6a9\ubcf4\ub2e4 \ud07d\ub2c8\ub2e4. \ud5a5\uc0c1\ub41c \uc548\uc804\uc131, \uc548\uc815\uc131 \ubc0f \ud655\uc7a5 \uc720\uc5f0\uc131\uc740 \uc6b0\uc218\ud55c \ucd1d \uc18c\uc720 \ube44\uc6a9\uc744 \uc81c\uacf5\ud569\ub2c8\ub2e4.<\/p>\n<h2>\uc790\uc8fc \ubb3b\ub294 \uc9c8\ubb38<\/h2>\n<h3>12V \uc81c\uc5b4 \uc2e0\ud638\ub85c 24V \ud0c0\uc774\uba38 \ub9b4\ub808\uc774\ub97c \uc0ac\uc6a9\ud560 \uc218 \uc788\uc2b5\ub2c8\uae4c?<\/h3>\n<p>\uc544\ub2c8\uc694, \uc9c1\uc811\uc801\uc73c\ub85c\ub294 \uc548 \ub429\ub2c8\ub2e4. 24V \ub9b4\ub808\uc774\ub294 \ucf54\uc77c\uc744 \uc548\uc815\uc801\uc73c\ub85c \uc791\ub3d9\uc2dc\ud0a4\uae30 \uc704\ud574 \uc57d 24V\uc758 \uc804\uc555\uc774 \ud544\uc694\ud569\ub2c8\ub2e4. 12V\ub9cc \uac00\ud558\uba74 \ucf54\uc77c \uc804\ub958\uac00 \ubd80\uc871\ud558\uc5ec \ub9b4\ub808\uc774\uac00 \uc804\ud658\ub418\uc9c0 \uc54a\uc2b5\ub2c8\ub2e4. 12V \uc815\uaca9 \ud0c0\uc774\uba38 \ub9b4\ub808\uc774\ub97c \uc0ac\uc6a9\ud558\uac70\ub098 \uc804\uc555 \ubcc0\ud658\uae30\ub97c \ucd94\uac00\ud574\uc57c \ud569\ub2c8\ub2e4. \uc77c\ubd80 \ubc94\uc6a9 \uc804\uc555 \ud0c0\uc774\uba38 \ub9b4\ub808\uc774(\uc608: 12-48V DC \ubc94\uc704)\ub294 \ub450 \uc804\uc555\uc744 \ubaa8\ub450 \uc218\uc6a9\ud560 \uc218 \uc788\uc2b5\ub2c8\ub2e4.<\/p>\n<h3>120V AC \ud0c0\uc774\uba38 \ub9b4\ub808\uc774\ub97c 230V AC\uc5d0 \uc5f0\uacb0\ud558\uba74 \uc5b4\ub5bb\uac8c \ub418\ub098\uc694?<\/h3>\n<p>\ub9b4\ub808\uc774\uac00 \uc989\uc2dc \uc2ec\uac01\ud558\uac8c \uc190\uc0c1\ub418\uac70\ub098 \ud30c\uad34\ub420 \uc218 \uc788\uc2b5\ub2c8\ub2e4. \uacfc\ub3c4\ud55c \uc804\uc555\uc740 \ucf54\uc77c \uacfc\uc5f4, \uc808\uc5f0 \ud30c\uad34 \ubc0f \uc7a0\uc7ac\uc801\uc778 \ud654\uc7ac \uc704\ud5d8\uc744 \ucd08\ub798\ud569\ub2c8\ub2e4. \ud56d\uc0c1 \uc804\uc555 \uc815\uaca9\uc774 \uacf5\uae09 \uc7a5\uce58\uc640 \uc815\ud655\ud788 \uc77c\uce58\ud558\ub294\uc9c0 \ud655\uc778\ud558\uc2ed\uc2dc\uc624. \ub2e4\uc911 \uc804\uc555 \uae30\ub2a5\uc774 \ud544\uc694\ud55c \uacbd\uc6b0 \uc804\uccb4 \uc804\uc555 \ubc94\uc704\uc5d0 \ub300\ud574 \uc815\uaca9\uc774 \uc9c0\uc815\ub41c \ubc94\uc6a9 \uc804\uc555 \ubaa8\ub378\uc744 \uc9c0\uc815\ud558\uc2ed\uc2dc\uc624.<\/p>\n<h3>24V DC \ud0c0\uc774\uba38 \ub9b4\ub808\uc774\ub85c 230V \ubd80\ud558\ub97c \uc81c\uc5b4\ud560 \uc218 \uc788\uc2b5\ub2c8\uae4c?<\/h3>\n<p>\uc608, \uadf8\ub807\uc2b5\ub2c8\ub2e4. \uc81c\uc5b4 \uc804\uc555(24V DC)\uc740 \uc811\uc810 \uc815\uaca9\uacfc \ub3c5\ub9bd\uc801\uc785\ub2c8\ub2e4. \ud0c0\uc774\uba38 \ub9b4\ub808\uc774 \uc811\uc810\uc740 \uc2a4\uc704\uce6d \uc6a9\ub7c9\uc5d0 \ub530\ub77c \ubcc4\ub3c4\ub85c \uc815\uaca9\uc774 \ub9e4\uaca8\uc9c0\uba70, \uc77c\ubc18\uc801\uc73c\ub85c 250V AC\uc5d0\uc11c 5A ~ 16A\uc785\ub2c8\ub2e4. \uc811\uc810 \uc815\uaca9\uc774 \ubd80\ud558 \uc694\uad6c \uc0ac\ud56d\uc744 \ucda9\uc871\ud558\uac70\ub098 \ucd08\uacfc\ud558\ub294\uc9c0 \ud655\uc778\ud558\uc2ed\uc2dc\uc624. 24V DC\ub294 \ub9b4\ub808\uc774 \ucf54\uc77c\uc5d0\ub9cc \uc804\uc6d0\uc744 \uacf5\uae09\ud558\uba70, \uc811\uc810\uc740 \ud6e8\uc52c \ub354 \ub192\uc740 \uc804\uc555\uc744 \uc548\uc804\ud558\uac8c \uc804\ud658\ud560 \uc218 \uc788\uc2b5\ub2c8\ub2e4.<\/p>\n<h3>\ud0c0\uc774\uba38 \ub9b4\ub808\uc774\uc5d0 24V AC\ub294 24V DC\uc640 \ub3d9\uc77c\ud55c\uac00\uc694?<\/h3>\n<p>\uc544\ub2c8\uc694, \uc774\uac83\ub4e4\uc740 \ub2e4\ub985\ub2c8\ub2e4. \uc77c\ubd80 \ud0c0\uc774\uba38 \ub9b4\ub808\uc774\ub294 AC, DC \ub610\ub294 \ub458 \ub2e4\ub9cc \ud5c8\uc6a9\ud569\ub2c8\ub2e4. AC \ub9b4\ub808\uc774\ub294 DC \ub9b4\ub808\uc774\uc640 \ub2e4\ub978 \ucf54\uc77c \uc124\uacc4\ub97c \uc0ac\uc6a9\ud569\ub2c8\ub2e4. \ud56d\uc0c1 \ub9b4\ub808\uc774 \uc0ac\uc591\uc5d0 \u201cAC\u201d, \u201cDC\u201d \ub610\ub294 \u201cAC\/DC\u201d\uac00 \ud45c\uc2dc\ub418\uc5b4 \uc788\ub294\uc9c0 \ud655\uc778\ud558\uc2ed\uc2dc\uc624. \ubc94\uc6a9 \uc804\uc555 VIOX \ud0c0\uc774\uba38 \ub9b4\ub808\uc774\ub294 \uc77c\ubc18\uc801\uc73c\ub85c 24V AC\uc640 24V DC\ub97c \uc0c1\ud638 \uad50\ud658\uc801\uc73c\ub85c \ud5c8\uc6a9\ud558\uba70 \uc785\ub825 \uc720\ud615\uc744 \uc790\ub3d9\uc73c\ub85c \uac10\uc9c0\ud569\ub2c8\ub2e4.<\/p>\n<h3>\uc0b0\uc5c5 \uc751\uc6a9 \ubd84\uc57c\uc5d0\uc11c 12V DC\ubcf4\ub2e4 24V DC\uac00 \uc120\ud638\ub418\ub294 \uc774\uc720\ub294 \ubb34\uc5c7\uc785\ub2c8\uae4c?<\/h3>\n<p>\uc8fc\uc694 \uc774\uc720 \ub450 \uac00\uc9c0: (1) \ub0ae\uc740 \uc804\ub958 \uc18c\ubaa8\u201424V\ub294 \ub3d9\uc77c\ud55c \uc804\ub825\uc5d0 \ub300\ud574 12V\uc758 \uc808\ubc18 \uc804\ub958\ub9cc \ud544\uc694\ub85c \ud568; (2) \ub354 \ub098\uc740 \ub178\uc774\uc988 \ub0b4\uc131. \ucd94\uac00\uc801\uc73c\ub85c, 24V\ub294 \ud655\ub9bd\ub41c PLC \ud45c\uc900\uc784.<\/p>\n<h3>24V DC \ud0c0\uc774\uba38 \ub9b4\ub808\uc774\uc5d0 \ud2b9\ubcc4\ud55c \uc804\uc6d0 \uacf5\uae09 \uc7a5\uce58\uac00 \ud544\uc694\ud55c\uac00\uc694?<\/h3>\n<p>\uc608, \uc815\uc804\uc555 24V DC \uc804\uc6d0 \uacf5\uae09 \uc7a5\uce58(DIN \ub808\uc77c \ub9c8\uc6b4\ud2b8 \uc2a4\uc704\uce6d \uc804\uc6d0 \uacf5\uae09 \uc7a5\uce58, 24V DC \uc815\uaca9, \ubd80\ud558\uc5d0 \ub530\ub77c 1-10A)\uac00 \ud544\uc694\ud569\ub2c8\ub2e4. \uc0b0\uc5c5\uc6a9 \uc804\uc6d0 \uacf5\uae09 \uc7a5\uce58\ub294 120V \ub610\ub294 230V AC \uc8fc\uc804\uc6d0\uc744 \uc548\uc815\uc801\uc778 24V DC\ub85c \ubcc0\ud658\ud569\ub2c8\ub2e4. \uc5f0\uacb0\ub41c \ubaa8\ub4e0 \uc7a5\uce58\uc5d0 \ub300\ud574 20%\uc758 \uc5ec\uc720\ub97c \ub450\uace0 \uc804\uc6d0 \uacf5\uae09 \uc7a5\uce58\uc758 \ud06c\uae30\ub97c \uc870\uc815\ud558\uc2ed\uc2dc\uc624. VIOX\ub294 \ud638\ud658 \uac00\ub2a5\ud55c DIN \ub808\uc77c \uc804\uc6d0 \uacf5\uae09 \uc7a5\uce58\ub97c \uc81c\uacf5\ud569\ub2c8\ub2e4.<\/p>\n<hr style=\"margin: 40px 0; border: 0; border-top: 1px solid #eee;\" \/>\n<p>\uc62c\ubc14\ub978 \ud0c0\uc774\uba38 \ub9b4\ub808\uc774 \uc81c\uc5b4 \uc804\uc555\uc744 \uc120\ud0dd\ud558\ub294 \uac83\uc740 \uc548\uc804, \ud638\ud658\uc131 \ubc0f \uc548\uc815\uc131\uc5d0 \uc601\ud5a5\uc744 \ubbf8\uce69\ub2c8\ub2e4. 24V DC\uac00 \ucd5c\uc2e0 \uc790\ub3d9\ud654\uc758 \uae00\ub85c\ubc8c \ud45c\uc900\uc774\uc9c0\ub9cc 12V DC\ub294 \ubaa8\ubc14\uc77c \uc560\ud50c\ub9ac\ucf00\uc774\uc158\uc5d0 \uc0ac\uc6a9\ub418\uba70 120V\/230V AC\ub294 \uc8fc\uc804\uc6d0 \uad6c\ub3d9 \uc7a5\ube44\uc5d0 \ud544\uc218\uc801\uc785\ub2c8\ub2e4. VIOX Electric\uc740 \ucd5c\ub300 \uc720\uc5f0\uc131\uc744 \uc704\ud574 \ubc94\uc6a9 \uc804\uc555 \ubaa8\ub378\uacfc \ud568\uaed8 \ubaa8\ub4e0 \uc804\uc555 \uc635\uc158\uc5d0\uc11c \ud0c0\uc774\uba38 \ub9b4\ub808\uc774\ub97c \uc81c\uacf5\ud569\ub2c8\ub2e4.<\/p>\n<\/div>\n<div class=\"simg-pop-btn\" style=\"top: 272px; left: 14px; display: none;\"><\/div>\n<div class=\"simg-pop-btn\" style=\"top: 272px; left: 14px; display: none;\"><\/div>","protected":false},"excerpt":{"rendered":"<p>Choosing the right control voltage for your timer relay\u201412V, 24V, 120V, or 230V\u2014directly impacts system safety, compatibility, and reliability. While 24V DC has become the modern standard for industrial automation due to its safety advantages and PLC compatibility, 12V suits mobile and battery-powered applications, and 120V\/230V AC options remain essential for high-power equipment and regional [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":20886,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1],"tags":[],"class_list":["post-20883","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"_links":{"self":[{"href":"https:\/\/test.viox.com\/ko\/wp-json\/wp\/v2\/posts\/20883","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/test.viox.com\/ko\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/test.viox.com\/ko\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/test.viox.com\/ko\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/test.viox.com\/ko\/wp-json\/wp\/v2\/comments?post=20883"}],"version-history":[{"count":2,"href":"https:\/\/test.viox.com\/ko\/wp-json\/wp\/v2\/posts\/20883\/revisions"}],"predecessor-version":[{"id":20885,"href":"https:\/\/test.viox.com\/ko\/wp-json\/wp\/v2\/posts\/20883\/revisions\/20885"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/test.viox.com\/ko\/wp-json\/wp\/v2\/media\/20886"}],"wp:attachment":[{"href":"https:\/\/test.viox.com\/ko\/wp-json\/wp\/v2\/media?parent=20883"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/test.viox.com\/ko\/wp-json\/wp\/v2\/categories?post=20883"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/test.viox.com\/ko\/wp-json\/wp\/v2\/tags?post=20883"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}