{"id":14333,"date":"2025-03-20T11:37:21","date_gmt":"2025-03-20T03:37:21","guid":{"rendered":"https:\/\/viox.com\/?post_type=product&#038;p=14333"},"modified":"2025-03-20T11:37:21","modified_gmt":"2025-03-20T03:37:21","slug":"viox-fct18-akr-pulse-delayed-timer-relay-with-control-signal","status":"publish","type":"product","link":"https:\/\/test.viox.com\/hu\/termek\/viox-fct18-akr-pulse-delayed-timer-relay-with-control-signal\/","title":{"rendered":"VIOX FCT18-AKR impulzus k\u00e9sleltetett id\u0151z\u00edt\u0151 rel\u00e9 vez\u00e9rl\u0151jelekkel"},"content":{"rendered":"<div class=\"product-intro\">\n<h2>Bevezet\u00e9s<\/h2>\n<p>A VIOX FCT18-AKR egy nagy pontoss\u00e1g\u00fa impulzus k\u00e9sleltetett id\u0151z\u00edt\u0151 rel\u00e9, amelyet olyan ipari automatiz\u00e1l\u00e1si rendszerekhez terveztek, amelyek pontos id\u0151z\u00edt\u00e9svez\u00e9rl\u00e9st ig\u00e9nyelnek. Az ON-k\u00e9sleltet\u00e9si (emelked\u0151 \u00e9l kiv\u00e1lt\u00f3) funkci\u00f3val ez az id\u0151z\u00edt\u0151 rel\u00e9 megb\u00edzhat\u00f3 m\u0171k\u00f6d\u00e9st biztos\u00edt sz\u00e1mos olyan alkalmaz\u00e1shoz, ahol a pontos id\u0151z\u00edt\u00e9s kulcsfontoss\u00e1g\u00fa. Az FCT18-AKR kiemelkedik kiv\u00e9teles sokoldal\u00fas\u00e1g\u00e1val, mivel 0,1 m\u00e1sodperct\u0151l ak\u00e1r 100 napig terjed\u0151 id\u0151tartom\u00e1nyt k\u00edn\u00e1l, \u00edgy egyar\u00e1nt alkalmas gyors reag\u00e1l\u00e1s\u00fa folyamatokhoz \u00e9s hossz\u00fa t\u00e1v\u00fa id\u0151f\u00fcgg\u0151 m\u0171veletekhez.<\/p>\n<h2>F\u0151bb jellemz\u0151k \u00e9s el\u0151ny\u00f6k<\/h2>\n<h3>Sokoldal\u00fa id\u0151z\u00edt\u00e9si funkci\u00f3<\/h3>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-14334\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-AKR-Pulse-Delayed-Timer-Relay-with-Control-Signal-timing-function.webp\" alt=\"VIOX FCT18-AKR Pulse Delayed Timer Relay with Control Signal timing function\" width=\"806\" height=\"300\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-AKR-Pulse-Delayed-Timer-Relay-with-Control-Signal-timing-function.webp 806w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-AKR-Pulse-Delayed-Timer-Relay-with-Control-Signal-timing-function-300x112.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-AKR-Pulse-Delayed-Timer-Relay-with-Control-Signal-timing-function-768x286.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-AKR-Pulse-Delayed-Timer-Relay-with-Control-Signal-timing-function-18x7.webp 18w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-AKR-Pulse-Delayed-Timer-Relay-with-Control-Signal-timing-function-600x223.webp 600w\" sizes=\"(max-width: 806px) 100vw, 806px\" \/><\/p>\n<p>Az FCT18-AKR emelked\u0151 \u00e9l\u0171 triggerel\u00e9ssel m\u0171k\u00f6d\u0151 ON k\u00e9sleltetett id\u0151z\u00edt\u0151k\u00e9nt m\u0171k\u00f6dik, ahol a m\u0171k\u00f6d\u00e9si id\u0151t az S (jel) bemenet pontosan szab\u00e1lyozza. Az Un (t\u00e1pell\u00e1t\u00e1s) bekapcsol\u00e1sakor \u00e9s az S jel kiv\u00e1lt\u00e1sakor az R rel\u00e9 az el\u0151re be\u00e1ll\u00edtott T id\u0151 eltelt\u00e9vel aktiv\u00e1l\u00f3dik. Ez az id\u0151z\u00edt\u00e9si funkci\u00f3 ide\u00e1lis olyan alkalmaz\u00e1sokhoz, amelyek a berendez\u00e9sek vagy folyamatok k\u00e9sleltetett aktiv\u00e1l\u00e1s\u00e1t ig\u00e9nylik.<\/p>\n<h3>Sz\u00e9les id\u0151tartom\u00e1ny kiv\u00e1laszt\u00e1sa<\/h3>\n<p>Az FCT18-AKR egyik legleny\u0171g\u00f6z\u0151bb tulajdons\u00e1ga a sz\u00e9les k\u00f6r\u0171 id\u0151beli rugalmass\u00e1g:<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-14335\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-AKR-Pulse-Delayed-Timer-Relay-with-Control-Signal-time-setting.webp\" alt=\"VIOX FCT18-AKR Pulse Delayed Timer Relay with Control Signal time setting\" width=\"834\" height=\"316\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-AKR-Pulse-Delayed-Timer-Relay-with-Control-Signal-time-setting.webp 834w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-AKR-Pulse-Delayed-Timer-Relay-with-Control-Signal-time-setting-300x114.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-AKR-Pulse-Delayed-Timer-Relay-with-Control-Signal-time-setting-768x291.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-AKR-Pulse-Delayed-Timer-Relay-with-Control-Signal-time-setting-18x7.webp 18w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-AKR-Pulse-Delayed-Timer-Relay-with-Control-Signal-time-setting-600x227.webp 600w\" sizes=\"(max-width: 834px) 100vw, 834px\" \/><\/p>\n<ul>\n<li>0.1-1s: Gyors reag\u00e1l\u00e1s\u00fa alkalmaz\u00e1sokhoz<\/li>\n<li>1-10s: Ide\u00e1lis a r\u00f6vid folyamatok k\u00e9sleltet\u00e9s\u00e9hez<\/li>\n<li>0.1-1m: T\u00f6k\u00e9letes percalap\u00fa id\u0151m\u00e9r\u00e9si ig\u00e9nyekhez<\/li>\n<li>1-10m: Alkalmas k\u00f6zepes id\u0151tartam\u00fa folyamatokhoz<\/li>\n<li>0,1-1 \u00f3ra: \u00d3ra alap\u00fa m\u0171veletekhez<\/li>\n<li>1-10 \u00f3ra: Hosszabb\u00edtott \u00f3rai id\u0151z\u00edt\u00e9s<\/li>\n<li>0,1-1 nap: Napi ciklusm\u0171veletek<\/li>\n<li>1-10nap: T\u00f6bbnapos id\u0151z\u00edt\u00e9si k\u00f6vetelm\u00e9nyek<\/li>\n<li>3-30nap: Havi m\u0171k\u00f6d\u00e9si ciklusok<\/li>\n<li>10-100nap: Kiterjesztett hossz\u00fa t\u00e1v\u00fa id\u0151z\u00edt\u00e9s<\/li>\n<\/ul>\n<p>Ez a figyelemre m\u00e9lt\u00f3 v\u00e1laszt\u00e9k kik\u00fcsz\u00f6b\u00f6li a t\u00f6bb id\u0151z\u00edt\u0151 rel\u00e9 sz\u00fcks\u00e9gess\u00e9g\u00e9t a k\u00fcl\u00f6nb\u00f6z\u0151 id\u0151z\u00edt\u00e9si k\u00f6vetelm\u00e9nyekkel rendelkez\u0151 rendszerekben, egyszer\u0171s\u00edtve a k\u00e9szletgazd\u00e1lkod\u00e1st \u00e9s cs\u00f6kkentve a k\u00f6lts\u00e9geket.<\/p>\n<h3>\u00c1ll\u00edthat\u00f3 ar\u00e1ny be\u00e1ll\u00edt\u00e1sa<\/h3>\n<p>Az FCT18-AKR pontos ar\u00e1nybe\u00e1ll\u00edt\u00e1ssal rendelkezik 10% \u00e9s 100% k\u00f6z\u00f6tt (5% l\u00e9p\u00e9sekben), lehet\u0151v\u00e9 t\u00e9ve az id\u0151z\u00edt\u00e9si peri\u00f3dus finomhangol\u00e1s\u00e1t az egyes kiv\u00e1lasztott tartom\u00e1nyokon bel\u00fcl. Ez a pontoss\u00e1gi szint biztos\u00edtja, hogy a rel\u00e9 kalibr\u00e1lhat\u00f3 legyen \u00fagy, hogy b\u00e1rmilyen alkalmaz\u00e1s pontos id\u0151z\u00edt\u00e9si k\u00f6vetelm\u00e9nyeinek megfeleljen.<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-14336\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-AKR-Pulse-Delayed-Timer-Relay-with-Control-Signal-ratio-setting.webp\" alt=\"VIOX FCT18-AKR Pulse Delayed Timer Relay with Control Signal ratio setting\" width=\"954\" height=\"252\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-AKR-Pulse-Delayed-Timer-Relay-with-Control-Signal-ratio-setting.webp 954w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-AKR-Pulse-Delayed-Timer-Relay-with-Control-Signal-ratio-setting-300x79.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-AKR-Pulse-Delayed-Timer-Relay-with-Control-Signal-ratio-setting-768x203.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-AKR-Pulse-Delayed-Timer-Relay-with-Control-Signal-ratio-setting-18x5.webp 18w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-AKR-Pulse-Delayed-Timer-Relay-with-Control-Signal-ratio-setting-600x158.webp 600w\" sizes=\"(max-width: 954px) 100vw, 954px\" \/><\/p>\n<h3>Univerz\u00e1lis t\u00e1pegys\u00e9g kompatibilit\u00e1s<\/h3>\n<p>A 12V \u00e9s 240V AC\/DC k\u00f6z\u00f6tti sz\u00e9les t\u00e1pell\u00e1t\u00e1si tartom\u00e1nynak k\u00f6sz\u00f6nhet\u0151en az FCT18-AKR kiv\u00e9teles telep\u00edt\u00e9si rugalmass\u00e1got k\u00edn\u00e1l, \u00edgy gyakorlatilag a vil\u00e1g b\u00e1rmely ipari \u00e1ramell\u00e1t\u00f3 rendszer\u00e9vel kompatibilis. Ez az univerz\u00e1lis t\u00e1pell\u00e1t\u00e1si k\u00e9pess\u00e9g cs\u00f6kkenti a k\u00e9szletig\u00e9nyt \u00e9s egyszer\u0171s\u00edti a specifik\u00e1ci\u00f3t.<\/p>\n<h3>Megb\u00edzhat\u00f3 teljes\u00edtm\u00e9ny<\/h3>\n<p>Az FCT18-AKR a megb\u00edzhat\u00f3s\u00e1g jegy\u00e9ben k\u00e9sz\u00fclt:<\/p>\n<ul>\n<li>Id\u0151hiba kevesebb, mint 0,5%<\/li>\n<li>Id\u0151beli elt\u00e9r\u00e9s mind\u00f6ssze 0,1%<\/li>\n<li>Ism\u00e9tl\u00e9si pontoss\u00e1g 0,5%<\/li>\n<li>Er\u0151s interferenciaelh\u00e1r\u00edt\u00f3 k\u00e9pess\u00e9g az elektromos zajos k\u00f6rnyezetben val\u00f3 stabil m\u0171k\u00f6d\u00e9shez<\/li>\n<\/ul>\n<h3>Egyszer\u0171 telep\u00edt\u00e9s \u00e9s be\u00e1ll\u00edt\u00e1s<\/h3>\n<p>A telep\u00edt\u00e9s \u00e9s a konfigur\u00e1l\u00e1s egyszer\u0171:<\/p>\n<ul>\n<li>K\u00f6nnyen be\u00e1ll\u00edthat\u00f3 id\u0151 \u00e9s ar\u00e1ny az intuit\u00edv t\u00e1rcs\u00e1s vez\u00e9rl\u00e9ssel<\/li>\n<li>DIN s\u00ednre szerelhet\u0151 (EN\/IEC 60715 kompatibilis)<\/li>\n<li>A term\u00e9k oldal\u00e1n tal\u00e1lhat\u00f3 egy\u00e9rtelm\u0171 kapcsol\u00e1si rajzok<\/li>\n<li>Kompakt m\u00e9retek: 90mm \u00d7 18mm \u00d7 64mm<\/li>\n<\/ul>\n<h3>Tart\u00f3s kialak\u00edt\u00e1s<\/h3>\n<p>Az ipari k\u00f6rnyezetre tervezett FCT18-AKR a k\u00f6vetkez\u0151ket k\u00edn\u00e1lja:<\/p>\n<ul>\n<li>M\u0171k\u00f6d\u00e9si h\u0151m\u00e9rs\u00e9klet-tartom\u00e1ny -20\u00b0C \u00e9s +60\u00b0C k\u00f6z\u00f6tt (-40\u00b0F \u00e9s +85\u00b0F k\u00f6z\u00f6tt)<\/li>\n<li>H\u0151m\u00e9rs\u00e9kleti egy\u00fctthat\u00f3 0,05%\/\u00b0C 20\u00b0C-on (0,05%\/\u00b0F 68\u00b0F-on)<\/li>\n<li>Mechanikai \u00e9lettartam 1\u00d710\u2077 m\u0171velet eset\u00e9n<\/li>\n<li>Elektromos \u00e9lettartam 1\u00d710\u2075 m\u0171velet eset\u00e9n<\/li>\n<li>IP20 v\u00e9detts\u00e9g<\/li>\n<li>Szennyezetts\u00e9gi szint 2 min\u0151s\u00edt\u00e9s<\/li>\n<\/ul>\n<h2>M\u0171szaki specifik\u00e1ci\u00f3k<\/h2>\n<h3>Modell azonos\u00edt\u00e1sa<\/h3>\n<p>Az FCT18-AKR term\u00e9kk\u00f3d a k\u00f6vetkez\u0151k\u00e9ppen \u00e9p\u00fcl fel:<\/p>\n<p><strong>FCT18-AkR X Y Z<\/strong><\/p>\n<p>Hol:<\/p>\n<ol>\n<li><strong>Funkci\u00f3<\/strong>: AkR - ON-k\u00e9sleltet\u00e9si id\u0151z\u00edt\u00e9si funkci\u00f3<\/li>\n<li><strong>Kimeneti t\u00edpus<\/strong>:\n<ul>\n<li>1: 1CO \u00e9rintkez\u0151 (1 SPDT)<\/li>\n<li>2: 2CO \u00e9rintkez\u0151 (2 SPDT)<\/li>\n<\/ul>\n<\/li>\n<li><strong>T\u00e1pfesz\u00fclts\u00e9g<\/strong>:\n<ul>\n<li>A: AC 230V<\/li>\n<li>D: DC 24V<\/li>\n<li>W: AC\/DC 12-240V<\/li>\n<\/ul>\n<\/li>\n<li><strong>Vez\u00e9rl\u0151jel<\/strong>:\n<ul>\n<li>N: NPN<\/li>\n<li>P: PNP<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n<h3>R\u00e9szletes specifik\u00e1ci\u00f3k<\/h3>\n<table border=\"1\" width=\"100%\" cellspacing=\"0\" cellpadding=\"5\">\n<thead>\n<tr>\n<th>Param\u00e9ter<\/th>\n<th>FCT18-AkR1<\/th>\n<th>FCT18-AkR2<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Bemeneti termin\u00e1l<\/td>\n<td>A1-A2<\/td>\n<td>A1-A2<\/td>\n<\/tr>\n<tr>\n<td>Fesz\u00fclts\u00e9gtartom\u00e1ny<\/td>\n<td>AC 230V \/ DC24V \/ AC\/DC 12-240V<\/td>\n<td>AC 230V \/ DC24V \/ AC\/DC 12-240V<\/td>\n<\/tr>\n<tr>\n<td>Energiafogyaszt\u00e1s<\/td>\n<td>AC 3,5VA \/ DC 2,0W<\/td>\n<td>AC 3,5VA \/ DC 2,0W<\/td>\n<\/tr>\n<tr>\n<td>Fesz\u00fclts\u00e9gt\u0171r\u00e9s<\/td>\n<td>-15% ~ +10%<\/td>\n<td>-15% ~ +10%<\/td>\n<\/tr>\n<tr>\n<td>Ell\u00e1t\u00e1s jelz\u00e9se<\/td>\n<td>Z\u00f6ld LED<\/td>\n<td>Z\u00f6ld LED<\/td>\n<\/tr>\n<tr>\n<td>Rel\u00e9 jelz\u00e9s<\/td>\n<td>Piros LED<\/td>\n<td>Piros LED<\/td>\n<\/tr>\n<tr>\n<td>Id\u0151tartom\u00e1nyok<\/td>\n<td>0.1s-100nap<\/td>\n<td>0.1s-100nap<\/td>\n<\/tr>\n<tr>\n<td>Id\u0151be\u00e1ll\u00edt\u00e1s<\/td>\n<td>Gomb<\/td>\n<td>Gomb<\/td>\n<\/tr>\n<tr>\n<td>Id\u0151beli elt\u00e9r\u00e9s<\/td>\n<td>0.1%<\/td>\n<td>0.1%<\/td>\n<\/tr>\n<tr>\n<td>Ism\u00e9tl\u00e9si pontoss\u00e1g<\/td>\n<td>0.5%<\/td>\n<td>0.5%<\/td>\n<\/tr>\n<tr>\n<td>H\u0151m\u00e9rs\u00e9kleti egy\u00fctthat\u00f3<\/td>\n<td>0,05%\/\u00b0C, 20\u00b0C-on (0,05%\/\u00b0F, 68\u00b0F-on)<\/td>\n<td>0,05%\/\u00b0C, 20\u00b0C-on (0,05%\/\u00b0F, 68\u00b0F-on)<\/td>\n<\/tr>\n<tr>\n<td>Kimeneti \u00e9rintkez\u0151<\/td>\n<td>1*SPDT<\/td>\n<td>2*SPDT<\/td>\n<\/tr>\n<tr>\n<td>N\u00e9vleges \u00e1ram<\/td>\n<td>1*16A<\/td>\n<td>2*16A<\/td>\n<\/tr>\n<tr>\n<td>Mechanikai \u00e9lettartam<\/td>\n<td>1*10\u2077<\/td>\n<td>1*10\u2077<\/td>\n<\/tr>\n<tr>\n<td>Elektromos \u00e9lettartam<\/td>\n<td>1*10\u2075<\/td>\n<td>1*10\u2075<\/td>\n<\/tr>\n<tr>\n<td>K\u00f6rnyezeti h\u0151m\u00e9rs\u00e9klet<\/td>\n<td>-20 ... +60\u00b0C \/ -40 ... +85\u00b0C<\/td>\n<td>-20 ... +60\u00b0C \/ -40 ... +85\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Szerel\u00e9s<\/td>\n<td>DIN s\u00edn EN\/IEC 60715<\/td>\n<td>DIN s\u00edn EN\/IEC 60715<\/td>\n<\/tr>\n<tr>\n<td>IP-besorol\u00e1s<\/td>\n<td>IP20<\/td>\n<td>IP20<\/td>\n<\/tr>\n<tr>\n<td>Csupasz\u00edt\u00e1si hossz<\/td>\n<td>7mm (0.28in)<\/td>\n<td>7mm (0.28in)<\/td>\n<\/tr>\n<tr>\n<td>Be\u00e9p\u00edtett magass\u00e1g<\/td>\n<td>\u22642200m<\/td>\n<td>\u22642200m<\/td>\n<\/tr>\n<tr>\n<td>Szennyezetts\u00e9gi szint<\/td>\n<td>2<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td>Maxim\u00e1lis k\u00e1belm\u00e9ret<\/td>\n<td>AWG13-20 0,4N-m<\/td>\n<td>AWG13-20 0,4N-m<\/td>\n<\/tr>\n<tr>\n<td>Dimenzi\u00f3<\/td>\n<td>90mm*18mm*64mm<\/td>\n<td>90mm*18mm*64mm<\/td>\n<\/tr>\n<tr>\n<td>S\u00faly<\/td>\n<td>kb. 90g<\/td>\n<td>kb. 90g<\/td>\n<\/tr>\n<tr>\n<td>Szabv\u00e1nyok<\/td>\n<td>GB\/T 14048.5, IEC60947-5-1, EN6812-1<\/td>\n<td>GB\/T 14048.5, IEC60947-5-1, EN6812-1<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Vezet\u00e9kek konfigur\u00e1ci\u00f3i<\/h2>\n<p>Az FCT18-AKR NPN \u00e9s PNP konfigur\u00e1ci\u00f3ban is bek\u00f6thet\u0151:<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-14337\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-AKR-Pulse-Delayed-Timer-Relay-with-Control-Signal-wiring.webp\" alt=\"VIOX FCT18-AKR Pulse Delayed Timer Relay with Control Signal wiring\" width=\"406\" height=\"386\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-AKR-Pulse-Delayed-Timer-Relay-with-Control-Signal-wiring.webp 406w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-AKR-Pulse-Delayed-Timer-Relay-with-Control-Signal-wiring-300x285.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-AKR-Pulse-Delayed-Timer-Relay-with-Control-Signal-wiring-13x12.webp 13w\" sizes=\"(max-width: 406px) 100vw, 406px\" \/><\/p>\n<h3>NPN konfigur\u00e1ci\u00f3<\/h3>\n<ul>\n<li>Csatlakoztassa a t\u00e1pegys\u00e9get az Un<\/li>\n<li>Csatlakoztassa a vez\u00e9rl\u0151jelet S<\/li>\n<li>Kimeneti csatlakoz\u00e1sok: OA1 (DC+ \/ AC L) \u00e9s OA2 (DC- \/ AC N)<\/li>\n<li>Termin\u00e1lcsatlakoz\u00e1sok: 11, 12, 14, 21, 22, 24<\/li>\n<\/ul>\n<h3>PNP konfigur\u00e1ci\u00f3<\/h3>\n<ul>\n<li>Csatlakoztassa a t\u00e1pegys\u00e9get az Un<\/li>\n<li>Csatlakoztassa a vez\u00e9rl\u0151jelet S<\/li>\n<li>Kimeneti csatlakoz\u00e1sok: OA1 (DC+ \/ AC L) \u00e9s OA2 (DC- \/ AC N)<\/li>\n<li>Termin\u00e1lcsatlakoz\u00e1sok: 11, 12, 14, 21, 22, 24<\/li>\n<\/ul>\n<h2>Dimenzi\u00f3<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-14338\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-AKR-Pulse-Delayed-Timer-Relay-with-Control-Signal-dimension.webp\" alt=\"VIOX FCT18-AKR Pulse Delayed Timer Relay with Control Signal dimension\" width=\"424\" height=\"376\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-AKR-Pulse-Delayed-Timer-Relay-with-Control-Signal-dimension.webp 424w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-AKR-Pulse-Delayed-Timer-Relay-with-Control-Signal-dimension-300x266.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VIOX-FCT18-AKR-Pulse-Delayed-Timer-Relay-with-Control-Signal-dimension-14x12.webp 14w\" sizes=\"(max-width: 424px) 100vw, 424px\" \/><\/p>\n<h2>Alkalmaz\u00e1sok<\/h2>\n<p>Az FCT18-AKR impulzus k\u00e9sleltetett id\u0151z\u00edt\u0151 rel\u00e9 ide\u00e1lis ipari \u00e9s kereskedelmi alkalmaz\u00e1sok sz\u00e9les k\u00f6r\u00e9hez:<\/p>\n<h3>Gy\u00e1rt\u00e1s automatiz\u00e1l\u00e1sa<\/h3>\n<ul>\n<li>Sz\u00e1ll\u00edt\u00f3rendszerek id\u0151z\u00edtett m\u0171veletekkel<\/li>\n<li>Szekvenci\u00e1lis g\u00e9pi m\u0171veletek<\/li>\n<li>Gy\u00e1rt\u00f3sori id\u0151z\u00edt\u00e9s ellen\u0151rz\u00e9se<\/li>\n<li>\u00d6sszeszerel\u0151sori folyamatok koordin\u00e1l\u00e1sa<\/li>\n<\/ul>\n<h3>\u00c9p\u00fcletkezel\u00e9s<\/h3>\n<ul>\n<li>HVAC-rendszer id\u0151z\u00edt\u00e9svez\u00e9rl\u00e9se<\/li>\n<li>Vil\u00e1g\u00edt\u00e1svez\u00e9rl\u0151 rendszerek<\/li>\n<li>Biztons\u00e1gi rendszer bel\u00e9p\u00e9si\/kil\u00e9p\u00e9si k\u00e9sleltet\u00e9se<\/li>\n<li>Szivatty\u00fa \u00e9s motorvez\u00e9rl\u00e9s id\u0151z\u00edt\u00e9se<\/li>\n<\/ul>\n<h3>Energiagazd\u00e1lkod\u00e1s<\/h3>\n<ul>\n<li>Teljes\u00edtm\u00e9nysorrend a berendez\u00e9sek ind\u00edt\u00e1s\u00e1hoz<\/li>\n<li>A terhel\u00e9s lekapcsol\u00e1s\u00e1nak id\u0151z\u00edt\u00e9se<\/li>\n<li>A gener\u00e1tor ind\u00edt\u00e1si sorrendje<\/li>\n<li>Energiatakar\u00e9koss\u00e1gi id\u0151z\u00edt\u00e9si ciklusok<\/li>\n<\/ul>\n<h3>V\u00edzkezel\u00e9s<\/h3>\n<ul>\n<li>Szivatty\u00fa ciklus id\u0151z\u00edt\u00e9se<\/li>\n<li>Sz\u0171r\u0151rendszer id\u0151z\u00edt\u00e9se<\/li>\n<li>K\u00e9sedelmes vegyszeradagol\u00e1s<\/li>\n<li>Visszamos\u00e1si ciklus vez\u00e9rl\u00e9se<\/li>\n<\/ul>\n<h3>Mez\u0151gazdas\u00e1g<\/h3>\n<ul>\n<li>\u00d6nt\u00f6z\u00e9s id\u0151z\u00edt\u00e9si rendszerek<\/li>\n<li>\u00c1llattakarm\u00e1nyoz\u00e1si berendez\u00e9sek id\u0151z\u00edt\u00e9se<\/li>\n<li>Az \u00fcvegh\u00e1zi kl\u00edmaszab\u00e1lyoz\u00e1s id\u0151z\u00edt\u00e9se<\/li>\n<li>Az akvakult\u00fara-rendszer id\u0151z\u00edt\u00e9se<\/li>\n<\/ul>\n<h3>\u00c1ltal\u00e1nos ipari alkalmaz\u00e1sok<\/h3>\n<ul>\n<li>Motorind\u00edt\u00e1s id\u0151z\u00edt\u00e9se<\/li>\n<li>Folyamatok szekven\u00e1l\u00e1sa<\/li>\n<li>Id\u0151alap\u00fa biztons\u00e1gi reteszel\u00e9s<\/li>\n<li>Berendez\u00e9s bemeleg\u00edt\u00e9si k\u00e9sedelmek<\/li>\n<\/ul>\n<h2>Telep\u00edt\u00e9si \u00e9s telep\u00edt\u00e9si \u00fatmutat\u00f3<\/h2>\n<h3>Szerel\u00e9si utas\u00edt\u00e1sok<\/h3>\n<ol>\n<li>Szerelje fel az FCT18-AKR-t egy szabv\u00e1nyos 35 mm-es DIN-s\u00ednre az EN\/IEC 60715 szabv\u00e1nynak megfelel\u0151en.<\/li>\n<li>Biztos\u00edtsa a megfelel\u0151 szell\u0151z\u00e9st a k\u00e9sz\u00fcl\u00e9k k\u00f6r\u00fcl.<\/li>\n<li>Az optim\u00e1lis teljes\u00edtm\u00e9ny \u00e9rdek\u00e9ben a k\u00e9sz\u00fcl\u00e9ket t\u00falzott rezg\u00e9sekt\u0151l, port\u00f3l \u00e9s mar\u00f3 g\u00e1zokt\u00f3l mentes helyre kell telep\u00edteni.<\/li>\n<\/ol>\n<h3>Bek\u00f6t\u00e9si l\u00e9p\u00e9sek<\/h3>\n<ol>\n<li>Csupasz\u00edtsa a vezet\u00e9keket 7 mm (0,28 h\u00fcvelyk) hossz\u00fas\u00e1g\u00fara.<\/li>\n<li>Csatlakoztassa a t\u00e1pegys\u00e9get az A1-A2 csatlakoz\u00f3khoz.<\/li>\n<li>Csatlakoztassa a vez\u00e9rl\u0151jelet az S csatlakoz\u00f3hoz.<\/li>\n<li>Csatlakoztassa a kimeneti eszk\u00f6z\u00f6ket a megfelel\u0151 \u00e9rintkez\u0151kapcsokhoz.<\/li>\n<li>Gy\u0151z\u0151dj\u00f6n meg arr\u00f3l, hogy minden csatlakoz\u00e1s szoros \u00e9s biztons\u00e1gos.<\/li>\n<\/ol>\n<h3>Id\u0151be\u00e1ll\u00edt\u00e1si elj\u00e1r\u00e1s<\/h3>\n<ol>\n<li>V\u00e1lassza ki a megfelel\u0151 id\u0151tartom\u00e1nyt a f\u0151 v\u00e1laszt\u00f3t\u00e1rcs\u00e1val.<\/li>\n<li>Finomhangolja az id\u0151\u00e9rt\u00e9ket az ar\u00e1nybe\u00e1ll\u00edt\u00f3 t\u00e1rcs\u00e1val (10%-100%).<\/li>\n<li>Kapcsolja be a t\u00e1pell\u00e1t\u00e1st, \u00e9s ellen\u0151rizze a helyes m\u0171k\u00f6d\u00e9st a LED-kijelz\u0151k ellen\u0151rz\u00e9s\u00e9vel.<\/li>\n<\/ol>\n<h2>Hibaelh\u00e1r\u00edt\u00e1si tippek<\/h2>\n<h3>A rel\u00e9 nem aktiv\u00e1l\u00f3dik<\/h3>\n<ul>\n<li>Ellen\u0151rizze a t\u00e1pegys\u00e9g csatlakoz\u00e1sait \u00e9s a fesz\u00fclts\u00e9get.<\/li>\n<li>Ellen\u0151rizze, hogy a vez\u00e9rl\u0151jel megfelel\u0151en van-e csatlakoztatva.<\/li>\n<li>Gy\u0151z\u0151dj\u00f6n meg arr\u00f3l, hogy az id\u0151be\u00e1ll\u00edt\u00e1s megfelel\u0151 az alkalmaz\u00e1shoz.<\/li>\n<li>Ellen\u0151rizze a laza csatlakoz\u00f3kat.<\/li>\n<\/ul>\n<h3>Id\u0151z\u00edt\u00e9si pontatlans\u00e1g<\/h3>\n<ul>\n<li>Ellen\u0151rizze, hogy az \u00fczemi h\u0151m\u00e9rs\u00e9klet a megadott tartom\u00e1nyon bel\u00fcl van-e.<\/li>\n<li>Ellen\u0151rizze a k\u00f6zelben l\u00e9v\u0151 elektrom\u00e1gneses zavarforr\u00e1sok megl\u00e9t\u00e9t.<\/li>\n<li>A fesz\u00fclts\u00e9g stabilit\u00e1s\u00e1nak biztos\u00edt\u00e1sa a megadott t\u0171r\u00e9shat\u00e1ron bel\u00fcl.<\/li>\n<li>Sz\u00fcks\u00e9g eset\u00e9n kalibr\u00e1lja \u00fajra az id\u0151be\u00e1ll\u00edt\u00e1sokat.<\/li>\n<\/ul>\n<h3>Nem m\u0171k\u00f6d\u0151 LED kijelz\u0151k<\/h3>\n<ul>\n<li>Ellen\u0151rizze a t\u00e1pegys\u00e9g csatlakoz\u00e1sait.<\/li>\n<li>Ellen\u0151rizze, hogy a fesz\u00fclts\u00e9g a megadott tartom\u00e1nyon bel\u00fcl van-e.<\/li>\n<li>Ha a mutat\u00f3k tov\u00e1bbra sem m\u0171k\u00f6dnek, l\u00e9pjen kapcsolatba az \u00fcgyf\u00e9lszolg\u00e1lattal.<\/li>\n<\/ul>\n<h2>Karbantart\u00e1s \u00e9s gondoz\u00e1s<\/h2>\n<p>Az FCT18-AKR-t minim\u00e1lis karbantart\u00e1sra tervezt\u00e9k. Az optim\u00e1lis teljes\u00edtm\u00e9ny \u00e9rdek\u00e9ben azonban:<\/p>\n<ul>\n<li>Rendszeresen ellen\u0151rizze a csatlakoz\u00f3k t\u00f6m\u00f6rs\u00e9g\u00e9t.<\/li>\n<li>Tartsa tiszt\u00e1n a k\u00e9sz\u00fcl\u00e9ket a port\u00f3l \u00e9s a t\u00f6rmel\u00e9kt\u0151l.<\/li>\n<li>Meghat\u00e1rozott k\u00f6rnyezeti felt\u00e9telek k\u00f6z\u00f6tt m\u0171k\u00f6dj\u00f6n.<\/li>\n<li>Rendszeresen r\u00f6gz\u00edtse az id\u0151z\u00edt\u00e9si teljes\u00edtm\u00e9nyt az esetleges elt\u00e9r\u00e9sek \u00e9szlel\u00e9se \u00e9rdek\u00e9ben.<\/li>\n<\/ul>\n<h2>Megfelel\u00e9s \u00e9s tan\u00fas\u00edt\u00e1s<\/h2>\n<p>Az FCT18-AKR id\u0151z\u00edt\u0151 rel\u00e9 gy\u00e1rt\u00e1sa megfelel a k\u00f6vetkez\u0151knek:<\/p>\n<ul>\n<li>GB\/T 14048.5<\/li>\n<li>IEC60947-5-1<\/li>\n<li>EN6812-1<\/li>\n<\/ul>\n<p>Ezek a szabv\u00e1nyok biztos\u00edtj\u00e1k a megb\u00edzhat\u00f3 teljes\u00edtm\u00e9nyt, az elektromos biztons\u00e1got \u00e9s az elektrom\u00e1gneses kompatibilit\u00e1st.<\/p>\n<h2>Garancia \u00e9s t\u00e1mogat\u00e1s<\/h2>\n<p>A VIOX az FCT18-AKR m\u00f6g\u00f6tt \u00e1tfog\u00f3 garanci\u00e1val \u00e9s m\u0171szaki t\u00e1mogat\u00e1ssal \u00e1ll. R\u00e9szletes garanci\u00e1lis inform\u00e1ci\u00f3k\u00e9rt \u00e9s technikai seg\u00edts\u00e9gny\u00fajt\u00e1s\u00e9rt forduljon \u00fcgyf\u00e9lszolg\u00e1latunkhoz, vagy l\u00e1togasson el weboldalunkra.<\/p>\n<h2>K\u00f6vetkeztet\u00e9s<\/h2>\n<p>A VIOX FCT18-AKR impulzusk\u00e9sleltetett id\u0151z\u00edt\u0151 rel\u00e9 ide\u00e1lis megold\u00e1st jelent olyan alkalmaz\u00e1sokhoz, amelyek prec\u00edz id\u0151z\u00edt\u00e9svez\u00e9rl\u00e9st ig\u00e9nyelnek sokoldal\u00fa tartom\u00e1nyi lehet\u0151s\u00e9gekkel. Sz\u00e9les \u00fczemi fesz\u00fclts\u00e9gtartom\u00e1nya, kiv\u00e9teles pontoss\u00e1ga \u00e9s robusztus ipari kialak\u00edt\u00e1sa alkalmass\u00e1 teszi a k\u00e9sz\u00fcl\u00e9ket t\u00f6bb ipar\u00e1g ig\u00e9nyes k\u00f6rnyezet\u00e9ben is. Ak\u00e1r milliszekundumos pontoss\u00e1got, ak\u00e1r t\u00f6bbnapos id\u0151z\u00edt\u00e9si ciklusokat ig\u00e9nyel az alkalmaz\u00e1sa, az FCT18-AKR megb\u00edzhat\u00f3 teljes\u00edtm\u00e9nyt ny\u00fajt, hogy rendszerei zavartalanul m\u0171k\u00f6djenek.<\/p>\n<p>A VIOX FCT18-AKR-rel kapcsolatos tov\u00e1bbi inform\u00e1ci\u00f3k\u00e9rt vagy az \u00d6n egyedi alkalmaz\u00e1si k\u00f6vetelm\u00e9nyeinek megvitat\u00e1s\u00e1\u00e9rt forduljon m\u0171szaki t\u00e1mogat\u00f3 csapatunkhoz, akik szak\u00e9rt\u0151i \u00fatmutat\u00e1st tudnak ny\u00fajtani a megval\u00f3s\u00edt\u00e1ssal \u00e9s konfigur\u00e1ci\u00f3val kapcsolatban.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<div class=\"markdown\">\n<p>A VIOX FCT18-AKR impulzus k\u00e9sleltetett id\u0151z\u00edt\u0151 rel\u00e9 pontos bekapcsol\u00e1si k\u00e9sleltet\u00e9st biztos\u00edt, amelyet emelked\u0151 \u00e9l\u0171 jel ind\u00edt. Rendk\u00edv\u00fcl sz\u00e9les 0,1s-100 napos tartom\u00e1nyt, &lt;0,5% hib\u00e1t, NPN\/PNP vez\u00e9rl\u00e9st, 1\/2 SPDT \u00e9rintkez\u0151ket, DIN s\u00ednre szerelhet\u0151 \u00e9s univerz\u00e1lis AC\/DC 12-240V-os t\u00e1pell\u00e1t\u00e1st biztos\u00edt. Ig\u00e9nyes ipari alkalmaz\u00e1sokhoz.<\/p>\n<\/div>\n<div class=\"MessageFooter-cvwndn leDsBF\">\n<div class=\"MessageMetadata-claACb fcypgW message-tokens has-metrics\"><\/div>\n<\/div>","protected":false},"featured_media":14339,"comment_status":"closed","ping_status":"closed","template":"","meta":{"inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[],"product_cat":[196,123],"product_tag":[],"class_list":{"0":"post-14333","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-time-relay","7":"product_cat-relay","8":"desktop-align-left","9":"tablet-align-left","10":"mobile-align-left","12":"first","13":"instock","14":"shipping-taxable","15":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/test.viox.com\/hu\/wp-json\/wp\/v2\/product\/14333","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/test.viox.com\/hu\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/test.viox.com\/hu\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/test.viox.com\/hu\/wp-json\/wp\/v2\/comments?post=14333"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/test.viox.com\/hu\/wp-json\/wp\/v2\/media\/14339"}],"wp:attachment":[{"href":"https:\/\/test.viox.com\/hu\/wp-json\/wp\/v2\/media?parent=14333"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/test.viox.com\/hu\/wp-json\/wp\/v2\/product_brand?post=14333"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/test.viox.com\/hu\/wp-json\/wp\/v2\/product_cat?post=14333"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/test.viox.com\/hu\/wp-json\/wp\/v2\/product_tag?post=14333"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}