{"id":13863,"date":"2025-03-05T16:37:49","date_gmt":"2025-03-05T08:37:49","guid":{"rendered":"https:\/\/viox.com\/?post_type=product&#038;p=13863"},"modified":"2025-03-05T16:51:39","modified_gmt":"2025-03-05T08:51:39","slug":"vkl11-residual-current-operated-circuit-breaker-2p-rccb","status":"publish","type":"product","link":"https:\/\/test.viox.com\/hu\/termek\/vkl11-residual-current-operated-circuit-breaker-2p-rccb\/","title":{"rendered":"VKL11 Fennmarad\u00f3 \u00e1ram m\u0171k\u00f6dtetett megszak\u00edt\u00f3 2P (RCCB)"},"content":{"rendered":"<div class=\"product-intro\">\n<h2>Bevezet\u00e9s a VKL11 RCCB-be<\/h2>\n<p>A VIOX VKL11 marad\u00e9k\u00e1ram-v\u00e9d\u0151kapcsol\u00f3 (RCCB) a villamos biztons\u00e1gi technol\u00f3gia \u00e9lvonal\u00e1t k\u00e9pviseli. Prec\u00edzi\u00f3s m\u00e9rn\u00f6ki tervez\u00e9ssel \u00e9s a legmagasabb nemzetk\u00f6zi szabv\u00e1nyoknak megfelel\u0151en gy\u00e1rtott VKL11 RCCB megb\u00edzhat\u00f3 v\u00e9delmet ny\u00fajt a marad\u00e9k\u00e1ramok ellen lakoss\u00e1gi, kereskedelmi \u00e9s ipari alkalmaz\u00e1sokban.<\/p>\n<p>A modern elektromos berendez\u00e9sek kritikus biztons\u00e1gi elemek\u00e9nt a VKL11 RCCB folyamatosan figyeli a f\u00e1zis- \u00e9s a nullavezet\u0151 \u00e1ram\u00e1nak egyens\u00faly\u00e1t, \u00e9s azonnal lev\u00e1lasztja az \u00e1ramk\u00f6rt, ha potenci\u00e1lisan vesz\u00e9lyes egyens\u00falyhi\u00e1nyt \u00e9szlel. Ez a gyors reag\u00e1l\u00e1s\u00fa mechanizmus megv\u00e9di az embereket az \u00e1ram\u00fct\u00e9s vesz\u00e9ly\u00e9t\u0151l, a vagyont\u00e1rgyakat pedig az elektromos t\u00fczekt\u0151l, \u00edgy n\u00e9lk\u00fcl\u00f6zhetetlen eszk\u00f6z minden elektromos berendez\u00e9sben.<\/p>\n<h2>1. \u00c1ltal\u00e1nos jellemz\u0151k \u00e9s funkci\u00f3k<\/h2>\n<h3>1.1 Els\u0151dleges funkci\u00f3<\/h3>\n<p>A VKL11 \u00e1ramv\u00e9d\u0151 kapcsol\u00f3t \u00fagy tervezt\u00e9k, hogy:<\/p>\n<ul>\n<li>Hat\u00e9konyan \u00e9s megb\u00edzhat\u00f3an vez\u00e9relheti az elektromos \u00e1ramk\u00f6r\u00f6ket<\/li>\n<li>V\u00e9dje meg az embereket a k\u00f6zvetett \u00e9rintkez\u00e9sekt\u0151l, \u00e9s biztos\u00edtson tov\u00e1bbi v\u00e9delmet a k\u00f6zvetlen \u00e9rintkez\u00e9sek ellen<\/li>\n<li>V\u00e9dje a berendez\u00e9seket a szigetel\u00e9si hib\u00e1k okozta t\u0171zvesz\u00e9lyekt\u0151l<\/li>\n<\/ul>\n<p>Ezeket a marad\u00e9k\u00e1ram-v\u00e9d\u0151kapcsol\u00f3kat kifejezetten lak\u00e1sokban, tercier szektorban \u00e9s ipari alkalmaz\u00e1sokban val\u00f3 haszn\u00e1latra tervezt\u00e9k, ahol az elektromos biztons\u00e1g kiemelked\u0151 fontoss\u00e1g\u00fa.<\/p>\n<h3>1.2 Kiv\u00e1laszt\u00e1si \u00fatmutat\u00f3 \u00e9s t\u00edpusok<\/h3>\n<h4>\u00c9szlelhet\u0151 hull\u00e1mforma-opci\u00f3k<\/h4>\n<p><strong>AC oszt\u00e1ly:<\/strong> A VKL11 AC oszt\u00e1ly\u00fa \u00e1ramv\u00e9d\u0151 kapcsol\u00f3 lassan n\u00f6vekv\u0151 szinuszos v\u00e1ltakoz\u00f3 \u00e1ram\u00fa marad\u00e9k\u00e1ramokra lett tervezve, standard v\u00e9delmet ny\u00fajtva a legt\u00f6bb h\u00e1ztart\u00e1si \u00e9s k\u00f6nny\u0171kereskedelmi alkalmaz\u00e1s sz\u00e1m\u00e1ra.<\/p>\n<p><strong>Egy oszt\u00e1ly:<\/strong> Az A oszt\u00e1ly\u00fa modellt szinuszos v\u00e1ltakoz\u00f3 \u00e1ram\u00fa marad\u00e9k\u00e1ramokra \u00e9s pulz\u00e1l\u00f3 egyen\u00e1ram\u00fa marad\u00e9k\u00e1ramokra egyar\u00e1nt tervezt\u00e9k, fokozott v\u00e9delmet ny\u00fajtva f\u00fcggetlen\u00fcl att\u00f3l, hogy ezek az \u00e1ramok hirtelen vagy lassan jelentkeznek.<\/p>\n<p><strong>ASi T\u00edpus:<\/strong> A VKL11 term\u00e9kcsal\u00e1d legfejlettebb opci\u00f3ja, az ASi t\u00edpus a k\u00f6vetkez\u0151ket tartalmazza:<\/p>\n<ul>\n<li>Teljes A t\u00edpus\u00fa jellemz\u0151k, plusz Si: Szuperimmuniz\u00e1lt (nagyfok\u00fa immunit\u00e1s a nem k\u00edv\u00e1nt kiold\u00e1sokkal szemben)<\/li>\n<li>Szinuszos v\u00e1ltakoz\u00f3 \u00e1ram\u00fa marad\u00e9k\u00e1ramok \u00e9s pulz\u00e1l\u00f3 egyen\u00e1ramok elleni v\u00e9delem<\/li>\n<li>Speci\u00e1lis G\/SI t\u00edpus sz\u0171r\u0151kkel a harmonikusok \u00e9s tranziens t\u00falfesz\u00fclts\u00e9gek okozta t\u00e9ves kiold\u00e1sok ellen<\/li>\n<li>K\u00e9pess\u00e9g ellen\u00e1llni a 8\/20 \u03bcs-os, 3000 A-es t\u00falfesz\u00fclts\u00e9gnek, mik\u00f6zben stabil \u00e1llapotot tart fenn<\/li>\n<li>G\/KV \u00e9s SI funkci\u00f3 egyar\u00e1nt az \u00e1tfog\u00f3 v\u00e9delem \u00e9rdek\u00e9ben<\/li>\n<\/ul>\n<h3>1.3 Tan\u00fas\u00edtv\u00e1nyok \u00e9s megfelel\u0151s\u00e9g<\/h3>\n<p>A VKL11 RCCB sorozat szigor\u00fa nemzetk\u00f6zi szabv\u00e1nyoknak felel meg, amit az UKCA \u00e9s CE j\u00f3v\u00e1hagy\u00e1sok \u00e9s tan\u00fas\u00edtv\u00e1nyok is igazolnak, biztos\u00edtva a legszigor\u00fabb biztons\u00e1gi el\u0151\u00edr\u00e1sok betart\u00e1s\u00e1t.<\/p>\n<h2>2. M\u0171szaki param\u00e9terek<\/h2>\n<table>\n<tbody>\n<tr>\n<th><\/th>\n<th>Standard<\/th>\n<th>IEC\/EN 61008-1<\/th>\n<\/tr>\n<tr>\n<td rowspan=\"14\">Elektromos jellemz\u0151k<\/td>\n<td>Modellsz\u00e1m.<\/td>\n<td>VKL11<\/td>\n<\/tr>\n<tr>\n<td>Lengyelek<\/td>\n<td>2P, 4P<\/td>\n<\/tr>\n<tr>\n<td>N\u00e9vleges \u00e1ram In<\/td>\n<td>16A, 25A, 32A, 40A, 63A, 80A, 100A, 100A<\/td>\n<\/tr>\n<tr>\n<td>N\u00e9vleges \u00e9rz\u00e9kenys\u00e9g I\u25b3n<\/td>\n<td>10mA (2P\/4P 16A-40A), 30mA, 100mA, 300mA<\/td>\n<\/tr>\n<tr>\n<td>N\u00e9vleges fesz\u00fclts\u00e9g Ue<\/td>\n<td>2P: 240V 4P: 415V<\/td>\n<\/tr>\n<tr>\n<td>Szigetel\u00e9si fesz\u00fclts\u00e9g Ui<\/td>\n<td>500V<\/td>\n<\/tr>\n<tr>\n<td>N\u00e9vleges frekvencia<\/td>\n<td>50\/60 Hz<\/td>\n<\/tr>\n<tr>\n<td>N\u00e9vleges marad\u00e9k teherb\u00edr\u00f3- \u00e9s szak\u00edt\u00f3k\u00e9pess\u00e9g I\u25b3m<\/td>\n<td>500A (In=16A, 25A, 32A, 40A)<br \/>\n630A (In=63A), 800A (In=80A), 1000A (In=100A)<\/td>\n<\/tr>\n<tr>\n<td>R\u00f6vidz\u00e1rlati \u00e1ram Inc=I\u25b3c<\/td>\n<td>6000A, 10000A<\/td>\n<\/tr>\n<tr>\n<td>T\u00edpus (a f\u00f6ldsziv\u00e1rg\u00e1s hull\u00e1mform\u00e1ja)<\/td>\n<td>AC, A<\/td>\n<\/tr>\n<tr>\n<td>Kipr\u00f3b\u00e1l\u00e1si id\u0151<\/td>\n<td>Pillanatnyi<\/td>\n<\/tr>\n<tr>\n<td>N\u00e9vleges impulzus\u00e1ll\u00e1si fesz\u00fclts\u00e9g (1.2\/50) Uimp<\/td>\n<td>6kV<\/td>\n<\/tr>\n<tr>\n<td>Dielektromos vizsg\u00e1lati fesz\u00fclts\u00e9g ind. Freq. 1 percig<\/td>\n<td>2.5<\/td>\n<\/tr>\n<tr>\n<td>Szennyezetts\u00e9gi fok<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"8\">Mechanikai jellemz\u0151k<\/td>\n<td>Elektromos \u00e9lettartam<\/td>\n<td>\u22652000<\/td>\n<\/tr>\n<tr>\n<td>Mechanikai \u00e9lettartam<\/td>\n<td>\u22652000<\/td>\n<\/tr>\n<tr>\n<td>Hiba\u00e1ram jelz\u0151<\/td>\n<td>Igen<\/td>\n<\/tr>\n<tr>\n<td>Termin\u00e1l v\u00e9delmi fok<\/td>\n<td>IP20<\/td>\n<\/tr>\n<tr>\n<td>K\u00f6rnyezeti h\u0151m\u00e9rs\u00e9klet (napi \u00e1tlag \u226435 \u2103)<\/td>\n<td>-25\u00b0C \u00e9s 55\u00b0C k\u00f6z\u00f6tt<\/td>\n<\/tr>\n<tr>\n<td>T\u00e1rol\u00e1si h\u0151m\u00e9rs\u00e9klet<\/td>\n<td>-40\u00b0C \u00e9s 70\u00b0C k\u00f6z\u00f6tt<\/td>\n<\/tr>\n<tr>\n<td>Termin\u00e1lcsatlakoz\u00e1s t\u00edpusa<\/td>\n<td>K\u00e1bel\/csapos gy\u0171jt\u0151s\u00edn<\/td>\n<\/tr>\n<tr>\n<td>Kimeneti m\u00e9ret fent\/alul a k\u00e1belhez<\/td>\n<td>25-35 mm\u00b2<br \/>\n18-3\/18-2 AWG<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\">Telep\u00edt\u00e9s<\/td>\n<\/tr>\n<tr>\n<td>Megh\u00faz\u00e1si nyomat\u00e9k<\/td>\n<td>2,5 N-m<br \/>\n22 In-lbs.<\/td>\n<\/tr>\n<tr>\n<td>Szerel\u00e9s<\/td>\n<td>DIN s\u00ednre EN 60715 (35mm) gyorskapocs seg\u00edts\u00e9g\u00e9vel<\/td>\n<\/tr>\n<tr>\n<td>Kapcsolat<\/td>\n<td>Fel\u00fclr\u0151l \u00e9s alulr\u00f3l<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>3. Kiold\u00e1si \u00e9rz\u00e9kenys\u00e9g \u00e9s teljes\u00edtm\u00e9ny<\/h2>\n<h3>Speci\u00e1lis kiold\u00e1si \u00e9rz\u00e9kenys\u00e9gi be\u00e1ll\u00edt\u00e1sok<\/h3>\n<p>A VKL11 RCCB t\u00f6bb \u00e9rz\u00e9kenys\u00e9gi szintet k\u00edn\u00e1l a k\u00fcl\u00f6nb\u00f6z\u0151 alkalmaz\u00e1si k\u00f6vetelm\u00e9nyeknek megfelel\u0151en:<\/p>\n<ul>\n<li><strong>10mA:<\/strong> Prec\u00edzi\u00f3s m\u0171szerek sziv\u00e1rg\u00e1s elleni v\u00e9delme \u00e9s f\u00fcrd\u0151szobai haszn\u00e1lat, amely a legmagasabb szint\u0171 v\u00e9delmet ny\u00fajtja azokon a ter\u00fcleteken, ahol v\u00edz \u00e9s elektromos \u00e1ram van a k\u00f6zelben<\/li>\n<li><strong>30mA:<\/strong> Kieg\u00e9sz\u00edt\u0151 v\u00e9delem a k\u00f6zvetlen \u00e9rintkez\u00e9s ellen, ide\u00e1lis lakoss\u00e1gi alkalmaz\u00e1sokhoz<\/li>\n<li><strong>100mA:<\/strong> Az I\u2206n &lt; 50R k\u00e9plet szerint koordin\u00e1lva a f\u00f6ldel\u0151rendszerrel, v\u00e9delmet ny\u00fajtva a k\u00f6zvetett \u00e9rintkez\u00e9sek ellen<\/li>\n<li><strong>300mA\/500mA:<\/strong> V\u00e9delem k\u00f6zvetett \u00e9rintkez\u00e9sek, valamint t\u0171zvesz\u00e9ly ellen, jellemz\u0151en ipari alkalmaz\u00e1sokban haszn\u00e1lj\u00e1k<\/li>\n<\/ul>\n<h3>Breaking Time teljes\u00edtm\u00e9ny<\/h3>\n<p>A VKL11 \u00e1ramv\u00e9d\u0151 h\u00e1rom k\u00fcl\u00f6nb\u00f6z\u0151 kikapcsol\u00e1si id\u0151t k\u00edn\u00e1l, hogy megfeleljen az adott alkalmaz\u00e1si k\u00f6vetelm\u00e9nyeknek:<\/p>\n<h4>Pillanatnyi<\/h4>\n<p>Azonnali kiold\u00e1st biztos\u00edt (id\u0151k\u00e9sleltet\u00e9s n\u00e9lk\u00fcl), \u2264100 ms v\u00e1laszid\u0151vel standard (norm\u00e1l t\u00edpus\u00fa) alkalmaz\u00e1sokhoz, ahol az azonnali lekapcsol\u00e1s kritikus fontoss\u00e1g\u00fa.<\/p>\n<h4>R\u00f6vid k\u00e9sleltet\u00e9s\u0171 Si, G, KV<\/h4>\n<p>10 ms~300 ms k\u00f6z\u00f6tti v\u00e1laszid\u0151vel (ASI, G, KV t\u00edpus) biztos\u00edtja a legal\u00e1bb 10 ms-os kiold\u00e1st. A Si: Super immuniz\u00e1lt funkci\u00f3 nagyfok\u00fa immunit\u00e1st biztos\u00edt a nem k\u00edv\u00e1nt kiold\u00e1sokkal szemben, \u00edgy ez az opci\u00f3 ide\u00e1lis olyan telep\u00edt\u00e9sekhez, ahol pillanatnyi ingadoz\u00e1sok el\u0151fordulhatnak.<\/p>\n<h4>Szelekt\u00edv S<\/h4>\n<p>A szelekt\u00edv opci\u00f3 teljes szelektivit\u00e1st biztos\u00edt egy nem szelekt\u00edv RCD-vel, amely lefel\u00e9 van elhelyezve, 150 ms \u00e9s 500 ms k\u00f6z\u00f6tti v\u00e1laszid\u0151vel (S t\u00edpus). Ez t\u00f6k\u00e9letess\u00e9 teszi kaszk\u00e1dos telep\u00edt\u00e9sekhez, ahol az eszk\u00f6z\u00f6k k\u00f6z\u00f6tti szelektivit\u00e1s elengedhetetlen.<\/p>\n<h2>4. Alkalmaz\u00e1sok \u00e9s el\u0151ny\u00f6k<\/h2>\n<h3>Ide\u00e1lis alkalmaz\u00e1sok a VKL11 RCCB sz\u00e1m\u00e1ra<\/h3>\n<p>A VKL11 RCCB sz\u00e9les k\u00f6r\u0171 alkalmaz\u00e1sokhoz alkalmas, bele\u00e9rtve:<\/p>\n<ul>\n<li><strong>Lak\u00f3\u00e9p\u00fcletek telep\u00edt\u00e9se:<\/strong> Alapvet\u0151 v\u00e9delem biztos\u00edt\u00e1sa otthonokban, lak\u00e1sokban \u00e9s lak\u00f3terekben<\/li>\n<li><strong>Kereskedelmi \u00e9p\u00fcletek:<\/strong> Biztons\u00e1g garant\u00e1l\u00e1sa irod\u00e1kban, \u00fczlethelyis\u00e9gekben \u00e9s k\u00f6z\u00e9p\u00fcletekben<\/li>\n<li><strong>K\u00f6nny\u0171ipari alkalmaz\u00e1sok:<\/strong> Berendez\u00e9sek \u00e9s szem\u00e9lyzet v\u00e9delme m\u0171helyk\u00f6rnyezetben<\/li>\n<li><strong>Szakter\u00fcletek:<\/strong> Fokozott v\u00e9delmet ny\u00fajt f\u00fcrd\u0151szob\u00e1kban, konyh\u00e1kban \u00e9s m\u00e1s olyan helyeken, ahol v\u00edz \u00e9s elektromoss\u00e1g is jelen van<\/li>\n<li><strong>Eloszt\u00f3t\u00e1bl\u00e1k:<\/strong> Integr\u00e1ci\u00f3 f\u0151- \u00e9s aleloszt\u00f3 szekr\u00e9nyekbe az \u00e1tfog\u00f3 elektromos biztons\u00e1g \u00e9rdek\u00e9ben<\/li>\n<\/ul>\n<h3>A VKL11 RCCB kiv\u00e1laszt\u00e1s\u00e1nak f\u0151 el\u0151nyei<\/h3>\n<ul>\n<li><strong>Fokozott biztons\u00e1g:<\/strong> V\u00e9d a k\u00f6zvetlen \u00e9s k\u00f6zvetett elektromos \u00e9rintkez\u00e9sek ellen<\/li>\n<li><strong>T\u0171zmegel\u0151z\u00e9s:<\/strong> A gyors lev\u00e1laszt\u00e1s seg\u00edt megel\u0151zni a szigetel\u00e9si hib\u00e1k \u00e1ltal okozott elektromos t\u00fczeket<\/li>\n<li><strong>Sokoldal\u00fa v\u00e9delem:<\/strong> K\u00fcl\u00f6nb\u00f6z\u0151 t\u00edpusokban (AC, A, ASi) kaphat\u00f3, hogy megfeleljen a k\u00fcl\u00f6nb\u00f6z\u0151 alkalmaz\u00e1si k\u00f6vetelm\u00e9nyeknek<\/li>\n<li><strong>T\u00edpusbe\u00e1ll\u00edt\u00e1sok:<\/strong> A standard AC-\u00e9rz\u00e9kel\u00e9st\u0151l a fejlett ASi-ig, amely nagyfok\u00fa immunit\u00e1st biztos\u00edt a nem k\u00edv\u00e1nt kiold\u00e1sokkal szemben<\/li>\n<li><strong>Nemzetk\u00f6zi megfelel\u00e9s:<\/strong> Megfelel a szigor\u00fa szabv\u00e1nyoknak, UKCA \u00e9s CE tan\u00fas\u00edtv\u00e1nnyal rendelkezik<\/li>\n<li><strong>Megb\u00edzhat\u00f3s\u00e1g:<\/strong> Hossz\u00fa elektromos \u00e9s mechanikai \u00e9lettartamra tervezve (\u22652000 m\u0171velet)<\/li>\n<li><strong>Sz\u00e9les m\u0171k\u00f6d\u00e9si tartom\u00e1ny:<\/strong> Hat\u00e9konyan m\u0171k\u00f6dik -25\u00b0C \u00e9s 55\u00b0C k\u00f6rnyezeti h\u0151m\u00e9rs\u00e9klet k\u00f6z\u00f6tt<\/li>\n<li><strong>Egyszer\u0171 telep\u00edt\u00e9s:<\/strong> Standard 35 mm-es DIN s\u00ednre szerelhet\u0151 gyorscsatlakoz\u00f3val<\/li>\n<\/ul>\n<h2>5. Telep\u00edt\u00e9s \u00e9s m\u00e9retek<\/h2>\n<h3>V\u00e1zlat- \u00e9s be\u00e9p\u00edt\u00e9si m\u00e9retek (mm)<\/h3>\n<p>A VKL11 \u00e1ramv\u00e9d\u0151 kapcsol\u00f3t eloszt\u00f3szekr\u00e9nyekbe val\u00f3 k\u00e9nyelmes beszerel\u00e9sre tervezt\u00e9k, szabv\u00e1nyos m\u00e9retekkel, amelyek megk\u00f6nny\u00edtik az integr\u00e1ci\u00f3t:<\/p>\n<ul>\n<li>Szerel\u00e9s: DIN s\u00ednre EN 60715 (35 mm) gyorsr\u00f6gz\u00edt\u0151vel<\/li>\n<li>Csatlakoz\u00e1s: Fel\u00fclr\u0151l \u00e9s alulr\u00f3l a rugalmas telep\u00edt\u00e9si lehet\u0151s\u00e9gek \u00e9rdek\u00e9ben<\/li>\n<li>Termin\u00e1l csatlakoz\u00e1s t\u00edpusa: Kompatibilis mind a k\u00e1beles, mind a t\u0171s gy\u0171jt\u0151s\u00ednnel<\/li>\n<li>K\u00e1belcsatlakoz\u00f3k kapacit\u00e1sa: 25-35 mm\u00b2 (18-3\/18-2 AWG)<\/li>\n<li>Gy\u0171jt\u0151s\u00edn csatlakoz\u00f3kapacit\u00e1sa: 10\/16 mm\u00b2 (18-8\/18-5 AWG)<\/li>\n<li>Megh\u00faz\u00e1si nyomat\u00e9k: 2,5 N\u00b7m (22 in-lbs) a biztons\u00e1gos csatlakoz\u00e1sokhoz<\/li>\n<\/ul>\n<h2>6. Kiv\u00e1laszt\u00e1si \u00fatmutat\u00f3: A megfelel\u0151 VKL11 \u00e1ramv\u00e9d\u0151 kapcsol\u00f3 kiv\u00e1laszt\u00e1sa<\/h2>\n<h3>1. l\u00e9p\u00e9s: A sz\u00fcks\u00e9ges t\u00edpus meghat\u00e1roz\u00e1sa hull\u00e1mforma-\u00e9rz\u00e9kel\u00e9s alapj\u00e1n<\/h3>\n<ul>\n<li><strong>T\u00edpus AC:<\/strong> Alapvet\u0151 alkalmaz\u00e1sokhoz standard szinuszos v\u00e1ltakoz\u00f3 \u00e1ramv\u00e9delemmel<\/li>\n<li><strong>A t\u00edpus:<\/strong> AC \u00e9s impulzusos egyen\u00e1ram\u00fa alkatr\u00e9szeket tartalmaz\u00f3 alkalmaz\u00e1sokhoz<\/li>\n<li><strong>ASi t\u00edpus:<\/strong> Olyan telep\u00edt\u00e9sekhez, amelyek nagyfok\u00fa immunit\u00e1st ig\u00e9nyelnek a nem k\u00edv\u00e1nt kiold\u00e1sokkal szemben, v\u00e9delemmel a felharmonikusok \u00e9s a tranziens t\u00falfesz\u00fclts\u00e9gek ellen<\/li>\n<\/ul>\n<h3>2. l\u00e9p\u00e9s: V\u00e1lassza ki a megfelel\u0151 \u00e1ramer\u0151ss\u00e9get (In)<\/h3>\n<p>V\u00e1lasszon a k\u00f6vetkez\u0151k k\u00f6z\u00fcl: 16 A, 25 A, 32 A, 40 A, 63 A, 80 A vagy 100 A az \u00e1ramk\u00f6r v\u00e1rhat\u00f3 maxim\u00e1lis \u00fczemi \u00e1ram\u00e1t\u00f3l f\u00fcgg\u0151en.<\/p>\n<h3>3. l\u00e9p\u00e9s: A sz\u00fcks\u00e9ges \u00e9rz\u00e9kenys\u00e9g (I\u2206n) meghat\u00e1roz\u00e1sa<\/h3>\n<ul>\n<li><strong>10mA:<\/strong> A legmagasabb v\u00e9delmi szinthez (prec\u00edzi\u00f3s m\u0171szerek, f\u00fcrd\u0151szob\u00e1k)<\/li>\n<li><strong>30mA:<\/strong> Standard szem\u00e9lyv\u00e9delem lakoss\u00e1gi alkalmaz\u00e1sokban<\/li>\n<li><strong>100mA:<\/strong> F\u00f6ldel\u0151rendszerekkel \u00f6sszehangolt v\u00e9delemhez<\/li>\n<li><strong>300mA:<\/strong> T\u0171zmegel\u0151z\u00e9si \u00e9s ipari alkalmaz\u00e1sokhoz<\/li>\n<\/ul>\n<h3>4. l\u00e9p\u00e9s: V\u00e1lasszon a 2P \u00e9s a 4P verzi\u00f3k k\u00f6z\u00fcl<\/h3>\n<p>Egyf\u00e1zis\u00fa alkalmaz\u00e1sokhoz (240V) v\u00e1lassza a 2P (2 p\u00f3lus\u00fa), h\u00e1romf\u00e1zis\u00fa alkalmaz\u00e1sokhoz (415V) pedig a 4P (4 p\u00f3lus\u00fa) lehet\u0151s\u00e9get.<\/p>\n<h3>5. l\u00e9p\u00e9s: Vegye figyelembe a sz\u00fcnetid\u0151-k\u00f6vetelm\u00e9nyeket<\/h3>\n<ul>\n<li><strong>Norm\u00e1l t\u00edpus:<\/strong> Standard azonnali m\u0171k\u00f6d\u00e9shez (\u2264100ms)<\/li>\n<li><strong>ASI, G, KV t\u00edpus:<\/strong> R\u00f6vid k\u00e9sleltet\u00e9st (10 ms~300 ms) ig\u00e9nyl\u0151 alkalmaz\u00e1sokhoz<\/li>\n<li><strong>S t\u00edpus:<\/strong> Szelekt\u00edv koordin\u00e1ci\u00f3hoz (150ms~500ms)<\/li>\n<\/ul>\n<h2>7. V\u00e1zlat \u00e9s telep\u00edt\u00e9si m\u00e9retek (mm)<\/h2>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-13889\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VKL11-RCCB-Outline-and-installation-Dimensions.webp\" alt=\"VKL11 RCCB Outline and installation Dimensions\" width=\"800\" height=\"243\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VKL11-RCCB-Outline-and-installation-Dimensions.webp 800w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VKL11-RCCB-Outline-and-installation-Dimensions-300x91.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VKL11-RCCB-Outline-and-installation-Dimensions-768x233.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VKL11-RCCB-Outline-and-installation-Dimensions-18x5.webp 18w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VKL11-RCCB-Outline-and-installation-Dimensions-600x182.webp 600w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<h2>8. Karbantart\u00e1si \u00e9s tesztel\u00e9si aj\u00e1nl\u00e1sok<\/h2>\n<p>B\u00e1r a VKL11 \u00e1ramv\u00e9d\u0151 kapcsol\u00f3t megb\u00edzhat\u00f3, hossz\u00fa t\u00e1v\u00fa m\u0171k\u00f6d\u00e9sre tervezt\u00e9k, az optim\u00e1lis teljes\u00edtm\u00e9ny biztos\u00edt\u00e1sa \u00e9rdek\u00e9ben rendszeres tesztel\u00e9s aj\u00e1nlott:<\/p>\n<ul>\n<li>Havonta tesztelje az \u00e1ram-v\u00e9d\u0151kapcsol\u00f3t a tesztgomb megnyom\u00e1s\u00e1val a megfelel\u0151 mechanikai m\u0171k\u00f6d\u00e9s ellen\u0151rz\u00e9s\u00e9hez.<\/li>\n<li>\u00c9vente v\u00e9gezzen szakk\u00e9pzett szem\u00e9lyzet \u00e1ltali ellen\u0151rz\u00e9seket a t\u00falmeleged\u00e9s, s\u00e9r\u00fcl\u00e9s vagy laza csatlakoz\u00e1sok jeleinek ellen\u0151rz\u00e9se \u00e9rdek\u00e9ben.<\/li>\n<li>A tervezett elektromos karbantart\u00e1s r\u00e9szek\u00e9nt ellen\u0151rizze a kiold\u00e1si id\u0151ket \u00e9s az \u00e9rz\u00e9kenys\u00e9get megfelel\u0151 tesztberendez\u00e9sekkel.<\/li>\n<li>Cser\u00e9lje ki az \u00e1ramv\u00e9d\u0151 kapcsol\u00f3t, ha a tesztgomb nem oldja ki a k\u00e9sz\u00fcl\u00e9ket, vagy ha b\u00e1rmilyen fizikai s\u00e9r\u00fcl\u00e9st \u00e9szlel.<\/li>\n<li>Dokument\u00e1lja az \u00f6sszes tesztet \u00e9s karbantart\u00e1si tev\u00e9kenys\u00e9get a helyi elektromos el\u0151\u00edr\u00e1soknak val\u00f3 megfelel\u00e9s \u00e9rdek\u00e9ben<\/li>\n<\/ul>\n<h2>9. Integr\u00e1ci\u00f3 elektromos rendszerekkel<\/h2>\n<h3>F\u0151eloszt\u00f3 t\u00e1bla telep\u00edt\u00e9se<\/h3>\n<p>A VKL11 \u00e1ramv\u00e9d\u0151 z\u00f6kken\u0151mentesen integr\u00e1lhat\u00f3 a f\u0151 eloszt\u00f3t\u00e1bl\u00e1kba, \u00e1tfog\u00f3 v\u00e9delmet ny\u00fajtva a teljes elektromos telep\u00edt\u00e9s sz\u00e1m\u00e1ra. Ebben a konfigur\u00e1ci\u00f3ban jellemz\u0151en t\u00f6bb, a l\u00e1nc t\u00f6bbi r\u00e9sz\u00e9t s\u00farol\u00f3 \u00e1ramk\u00f6rt v\u00e9d.<\/p>\n<h3>Aleloszt\u00f3 t\u00e1bla telep\u00edt\u00e9se<\/h3>\n<p>C\u00e9lzottabb v\u00e9delem \u00e9rdek\u00e9ben a VKL11 aleloszt\u00f3kba telep\u00edthet\u0151, \u00edgy meghat\u00e1rozott ter\u00fcleteket vagy berendez\u00e9seket v\u00e9dve. Ez az elrendez\u00e9s lehet\u0151v\u00e9 teszi a szelekt\u00edv koordin\u00e1ci\u00f3t a fels\u0151bb v\u00e9delmi eszk\u00f6z\u00f6kkel.<\/p>\n<h3>Kaszk\u00e1d konfigur\u00e1ci\u00f3<\/h3>\n<p>Nagyobb telep\u00edt\u00e9sekben a VKL11 \u00e1ramv\u00e9d\u0151 kapcsol\u00f3k kaszk\u00e1d konfigur\u00e1ci\u00f3ban is elhelyezhet\u0151k, szelekt\u00edv (S-t\u00edpus\u00fa) eszk\u00f6z\u00f6kkel a t\u00e1pell\u00e1t\u00e1s, standard eszk\u00f6z\u00f6kkel pedig a t\u00e1pell\u00e1t\u00e1s oldal\u00e1n, biztos\u00edtva a megfelel\u0151 szelektivit\u00e1st \u00e9s megel\u0151zve a sz\u00fcks\u00e9gtelen \u00e1ramkimarad\u00e1sokat.<\/p>\n<h2>K\u00f6vetkeztet\u00e9s: Mi\u00e9rt v\u00e1lassza a VKL11 RCCB-t?<\/h2>\n<p>A VIOX VKL11 \u00e1ram-v\u00e9d\u0151kapcsol\u00f3 az ide\u00e1lis egyens\u00falyt k\u00e9pviseli a fejlett v\u00e9delem, a megb\u00edzhat\u00f3s\u00e1g \u00e9s a sokoldal\u00fas\u00e1g k\u00f6z\u00f6tt. \u00c1tfog\u00f3 t\u00edpus-, \u00e9rz\u00e9kenys\u00e9g- \u00e9s teljes\u00edtm\u00e9nyjellemz\u0151inek v\u00e1laszt\u00e9k\u00e1val gyakorlatilag b\u00e1rmilyen alkalmaz\u00e1shoz testreszabott elektromos biztons\u00e1gi megold\u00e1sokat k\u00edn\u00e1l.<\/p>\n<p>A VKL11 \u00e1ramv\u00e9d\u0151 kapcsol\u00f3 kiv\u00e1laszt\u00e1s\u00e1val egy olyan biztons\u00e1gi eszk\u00f6zbe fektet be, amely nemcsak megfelel a jelenlegi nemzetk\u00f6zi szabv\u00e1nyoknak, hanem min\u0151s\u00e9gi \u00e9s tart\u00f3s kialak\u00edt\u00e1s\u00e1val \u00e9vekig tart\u00f3 megb\u00edzhat\u00f3 szolg\u00e1ltat\u00e1st ny\u00fajt. Ak\u00e1r lakoss\u00e1gi, kereskedelmi, ak\u00e1r ipari telep\u00edt\u00e9sekr\u0151l van sz\u00f3, a VKL11 biztos\u00edtja azt a nyugalmat, hogy elektromos rendszereit ipar\u00e1gvezet\u0151 technol\u00f3gia v\u00e9di.<\/p>\n<p>A VKL11 RCCB-vel kapcsolatos tov\u00e1bbi inform\u00e1ci\u00f3k\u00e9rt vagy az \u00d6n konkr\u00e9t alkalmaz\u00e1si k\u00f6vetelm\u00e9nyeinek megbesz\u00e9l\u00e9s\u00e9hez k\u00e9rj\u00fck, vegye fel a kapcsolatot m\u0171szaki t\u00e1mogat\u00e1si csapatunkkal, vagy l\u00e1togasson el weboldalunkra.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<div class=\"markdown\">\n<p>A VKL11 RCCB egy nagy teljes\u00edtm\u00e9ny\u0171 marad\u00e9k\u00e1ram-v\u00e9d\u0151kapcsol\u00f3, amelyet lakoss\u00e1gi, kereskedelmi \u00e9s ipari alkalmaz\u00e1sokhoz terveztek. V\u00e9delmet ny\u00fajt az \u00e1ram\u00fct\u00e9s \u00e9s a t\u0171zvesz\u00e9ly ellen az AC \u00e9s DC marad\u00e9k\u00e1ramok \u00e9rz\u00e9kel\u00e9s\u00e9vel. 2P \u00e9s 4P konfigur\u00e1ci\u00f3ban kaphat\u00f3, 10 mA \u00e9s 300 mA k\u00f6z\u00f6tti \u00e9rz\u00e9kenys\u00e9gi szinttel, megb\u00edzhat\u00f3 biztons\u00e1got \u00e9s a nemzetk\u00f6zi szabv\u00e1nyoknak val\u00f3 megfelel\u00e9st biztos\u00edt.<\/p>\n<\/div>","protected":false},"featured_media":13890,"comment_status":"closed","ping_status":"closed","template":"","meta":{"inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[],"product_cat":[131],"product_tag":[],"class_list":{"0":"post-13863","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-rccb","7":"desktop-align-left","8":"tablet-align-left","9":"mobile-align-left","11":"first","12":"instock","13":"shipping-taxable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/test.viox.com\/hu\/wp-json\/wp\/v2\/product\/13863","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/test.viox.com\/hu\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/test.viox.com\/hu\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/test.viox.com\/hu\/wp-json\/wp\/v2\/comments?post=13863"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/test.viox.com\/hu\/wp-json\/wp\/v2\/media\/13890"}],"wp:attachment":[{"href":"https:\/\/test.viox.com\/hu\/wp-json\/wp\/v2\/media?parent=13863"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/test.viox.com\/hu\/wp-json\/wp\/v2\/product_brand?post=13863"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/test.viox.com\/hu\/wp-json\/wp\/v2\/product_cat?post=13863"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/test.viox.com\/hu\/wp-json\/wp\/v2\/product_tag?post=13863"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}