{"id":12008,"date":"2024-12-27T01:10:34","date_gmt":"2024-12-26T17:10:34","guid":{"rendered":"https:\/\/viox.com\/?post_type=product&#038;p=12008"},"modified":"2024-12-27T01:10:34","modified_gmt":"2024-12-26T17:10:34","slug":"aluminum-alloy-breather-vent-plug","status":"publish","type":"product","link":"https:\/\/test.viox.com\/hu\/termek\/aluminum-alloy-breather-vent-plug\/","title":{"rendered":"Alum\u00ednium \u00f6tv\u00f6zetb\u0151l k\u00e9sz\u00fclt l\u00e9gtelen\u00edt\u0151 szell\u0151z\u0151 dug\u00f3"},"content":{"rendered":"<div class=\"product-intro\">\n<h2>Alum\u00ednium\u00f6tv\u00f6zetb\u0151l k\u00e9sz\u00fclt l\u00e9gtelen\u00edt\u0151 dug\u00f3<\/h2>\n<h2>\u00c1ttekint\u00e9s<\/h2>\n<p>A VIOX alum\u00ednium\u00f6tv\u00f6zetb\u0151l k\u00e9sz\u00fclt l\u00e9gtelen\u00edt\u0151 dug\u00f3 nyom\u00e1segyens\u00faly fenntart\u00e1s\u00e1ra \u00e9s a p\u00e1ralecsap\u00f3d\u00e1s megakad\u00e1lyoz\u00e1s\u00e1ra szolg\u00e1l k\u00fcl\u00f6nf\u00e9le ipari alkalmaz\u00e1sokban. Ez a szell\u0151z\u0151dug\u00f3 lehet\u0151v\u00e9 teszi a leveg\u0151 \u00e1thalad\u00e1s\u00e1t, mik\u00f6zben megakad\u00e1lyozza a nedvess\u00e9g \u00e9s a por bejut\u00e1s\u00e1t, \u00edgy ide\u00e1lis vesz\u00e9lyes ter\u00fcleteken \u00e9s robban\u00e1sbiztos elektromos berendez\u00e9sek csatlakoz\u00e1saihoz. Robusztus kialak\u00edt\u00e1s\u00fa, kiv\u00e1l\u00f3 min\u0151s\u00e9g\u0171 anyagokb\u00f3l k\u00e9sz\u00fclt, \u00edgy tart\u00f3s \u00e9s megb\u00edzhat\u00f3.<\/p>\n<h2>M\u0171szaki param\u00e9terek<\/h2>\n<table>\n<tbody>\n<tr>\n<th>T\u00e9tel<\/th>\n<th>R\u00e9szletek<\/th>\n<\/tr>\n<tr>\n<td>Sz\u00e1l<\/td>\n<td>Metrikus, PG, G (PF), \u00e9s NPT<\/td>\n<\/tr>\n<tr>\n<td>V\u00e9delmi fokozat<\/td>\n<td>IP65-IP68 (O-gy\u0171r\u0171vel)<\/td>\n<\/tr>\n<tr>\n<td>Munkah\u0151m\u00e9rs\u00e9klet<\/td>\n<td>-40\u2103 \u00e9s 125\u2103 k\u00f6z\u00f6tt<\/td>\n<\/tr>\n<tr>\n<td>Anyagok<\/td>\n<td>Alum\u00ednium\u00f6tv\u00f6zet<\/td>\n<\/tr>\n<tr>\n<td>Leveg\u0151\u00e1tereszt\u0151 k\u00e9pess\u00e9g<\/td>\n<td>2200 ml\/perc (dp=70 mbar)<\/td>\n<\/tr>\n<tr>\n<td>V\u00edz bel\u00e9p\u00e9si nyom\u00e1s<\/td>\n<td>&gt;10 kPa (kb. 1 m\u00e9teres v\u00edznyom\u00e1s)<\/td>\n<\/tr>\n<tr>\n<td>S\u00f3spray ellen\u00e1ll\u00e1s<\/td>\n<td>96 \u00f3ra (IEC 68-2-11)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Jellemz\u0151k<\/h2>\n<ul>\n<li>Lehet\u0151v\u00e9 teszi a leveg\u0151 \u00e1thalad\u00e1s\u00e1t, mik\u00f6zben megakad\u00e1lyozza a nedvess\u00e9g \u00e9s a por bejut\u00e1s\u00e1t.<\/li>\n<li>Fenntartja a nyom\u00e1segyens\u00falyt \u00e9s elker\u00fcli a kondenz\u00e1ci\u00f3t a burkolatokban.<\/li>\n<li>Testre szabhat\u00f3 v\u00edz\u00e1ll\u00f3s\u00e1gi szint a v\u00edzm\u00e9lys\u00e9g \u00e9s a l\u00e9g\u00e1tereszt\u0151 k\u00e9pess\u00e9g alapj\u00e1n.<\/li>\n<li>Ide\u00e1lis vesz\u00e9lyes ter\u00fcleteken, robban\u00e1sbiztos elektromos berendez\u00e9sekhez, vegyiparban, k\u0151olajiparban, valamint a villamosipar, k\u00f6nny\u0171ipar \u00e9s g\u00e9pipar k\u00fcl\u00f6nb\u00f6z\u0151 \u00e1gazataiban.<\/li>\n<\/ul>\n<h2>Term\u00e9k le\u00edr\u00e1sa<\/h2>\n<p>A VIOX alum\u00ednium\u00f6tv\u00f6zetb\u0151l k\u00e9sz\u00fclt l\u00e9gtelen\u00edt\u0151 dug\u00f3 egy sokoldal\u00fa eszk\u00f6z, amelyet g\u00e1z \u00e9s folyad\u00e9k \u00e1raml\u00e1s\u00e1nak szab\u00e1lyoz\u00e1s\u00e1ra terveztek. Tart\u00f3s h\u00e9jb\u00f3l, rug\u00f3s lemezekb\u0151l \u00e9s l\u00e9legz\u0151 anyagokb\u00f3l \u00e1ll, \u00edgy alkalmass\u00e1 teszi g\u00e1zok vagy folyad\u00e9kok szab\u00e1lyoz\u00e1s\u00e1ra, kiegyens\u00falyoz\u00e1s\u00e1ra \u00e9s kienged\u00e9s\u00e9re cs\u0151vezet\u00e9kekben \u00e9s tart\u00e1lyokban. A h\u00e9j kiv\u00e1l\u00f3 min\u0151s\u00e9g\u0171 alum\u00ednium\u00f6tv\u00f6zetb\u0151l vagy nikkel bevonat\u00fa s\u00e1rgar\u00e9zb\u0151l k\u00e9sz\u00fclt, kiv\u00e1l\u00f3 korr\u00f3zi\u00f3\u00e1ll\u00f3s\u00e1ggal \u00e9s szil\u00e1rds\u00e1ggal. A nagy rugalmass\u00e1g\u00fa \u00f6tv\u00f6zetb\u0151l k\u00e9sz\u00fclt rug\u00f3s lemez j\u00f3 rugalmass\u00e1got \u00e9s t\u00f6m\u00edtetts\u00e9get biztos\u00edt, lehet\u0151v\u00e9 t\u00e9ve a gyors \u00e9s pontos nyom\u00e1sbe\u00e1ll\u00edt\u00e1st. A l\u00e9legz\u0151 anyagok, bele\u00e9rtve a kiv\u00e1l\u00f3 min\u0151s\u00e9g\u0171 h\u00e1l\u00f3s lemezeket is, a k\u00fcl\u00f6nb\u00f6z\u0151 folyad\u00e9kjellemz\u0151k alapj\u00e1n optim\u00e1lis szell\u0151z\u00e9s \u00e9rdek\u00e9ben \u00e1ll\u00edthat\u00f3k be.<\/p>\n<h2>A term\u00e9k jellemz\u0151i<\/h2>\n<ul>\n<li><strong>Magas l\u00e9g\u00e1tereszt\u0151 k\u00e9pess\u00e9g:<\/strong> Biztos\u00edtja a berendez\u00e9s j\u00f3 bels\u0151 szell\u0151z\u00e9s\u00e9t, n\u00f6velve a feldolgoz\u00e1s hat\u00e9konys\u00e1g\u00e1t \u00e9s teljes\u00edtm\u00e9ny\u00e9t.<\/li>\n<li><strong>Er\u0151s kop\u00e1s\u00e1ll\u00f3s\u00e1g:<\/strong> Sima fel\u00fclet, amely ellen\u00e1ll a szennyez\u0151 anyagoknak, \u00edgy hossz\u00fa t\u00e1von meg\u0151rzi a teljes\u00edtm\u00e9nyt.<\/li>\n<li><strong>Magas h\u0151m\u00e9rs\u00e9kleti ellen\u00e1ll\u00e1s:<\/strong> Magas h\u0151m\u00e9rs\u00e9kletnek ellen\u00e1ll deform\u00e1l\u00f3d\u00e1s, olvad\u00e1s vagy reped\u00e9s n\u00e9lk\u00fcl.<\/li>\n<li><strong>V\u00edz\u00e1ll\u00f3 \u00e9s por\u00e1ll\u00f3:<\/strong> V\u00e9di a bels\u0151 berendez\u00e9seket a k\u00fcls\u0151 szennyez\u0151d\u00e9sekt\u0151l.<\/li>\n<li><strong>Nagy szil\u00e1rds\u00e1g:<\/strong> Nagy szil\u00e1rds\u00e1got \u00e9s f\u00e1rad\u00e1s\u00e1ll\u00f3s\u00e1got k\u00edn\u00e1l a stabil hossz\u00fa t\u00e1v\u00fa m\u0171k\u00f6d\u00e9shez.<\/li>\n<\/ul>\n<h2>Term\u00e9kel\u0151ny\u00f6k<\/h2>\n<ul>\n<li><strong>Gazdas\u00e1gos \u00e9s megfizethet\u0151:<\/strong> K\u00f6lts\u00e9ghat\u00e9kony, alacsonyabb haszn\u00e1lati k\u00f6lts\u00e9gekkel.<\/li>\n<li><strong>K\u00e9nyelmes karbantart\u00e1s:<\/strong> Egyszer\u0171 \u00e9s k\u00e9nyelmes karbantart\u00e1s hossz\u00fa \u00e9lettartam mellett.<\/li>\n<li><strong>Sz\u00e9les k\u00f6r\u0171 alkalmazhat\u00f3s\u00e1g:<\/strong> Alkalmas g\u00e1z- \u00e9s folyad\u00e9kkezel\u00e9sre \u00e9s sz\u0171r\u00e9sre k\u00fcl\u00f6nb\u00f6z\u0151 ter\u00fcleteken.<\/li>\n<li><strong>K\u00f6nny\u0171szerkezetes kialak\u00edt\u00e1s:<\/strong> Cs\u00f6kkenti a berendez\u00e9s s\u00faly\u00e1t, jav\u00edtva a m\u0171k\u00f6d\u00e9si hat\u00e9konys\u00e1got \u00e9s teljes\u00edtm\u00e9nyt.<\/li>\n<\/ul>\n<h2>Alkalmaz\u00e1si mez\u0151k<\/h2>\n<ul>\n<li><strong>Orvosi ter\u00fclet:<\/strong> Orvosi berendez\u00e9sekben, p\u00e9ld\u00e1ul l\u00e9legeztet\u0151g\u00e9pekben \u00e9s hemodial\u00edzisg\u00e9pekben haszn\u00e1latos.<\/li>\n<li><strong>Ipari ter\u00fclet:<\/strong> Alkalmas g\u00e1zsz\u0171r\u00e9shez, folyad\u00e9kkezel\u00e9shez \u00e9s k\u00f6rnyezetv\u00e9delmi berendez\u00e9sekhez.<\/li>\n<li><strong>\u00c9p\u00edt\u0151ipari ter\u00fclet:<\/strong> \u00c9p\u00edt\u0151anyagokban, p\u00e9ld\u00e1ul v\u00e1laszfalakban \u00e9s falpanelekben haszn\u00e1latos.<\/li>\n<\/ul>\n<h2>M\u0171szaki adatlap<\/h2>\n<table>\n<tbody>\n<tr>\n<th>Sz\u00e1l<\/th>\n<th>F\u0151 anyag<\/th>\n<th>Leveg\u0151\u00e1tereszt\u0151 k\u00e9pess\u00e9g<\/th>\n<th>Nyom\u00e1s tartom\u00e1ny<\/th>\n<th>Menethossz (mm)<\/th>\n<th>Kulcs\u00e1tm\u00e9r\u0151 (mm)<\/th>\n<th>\u00c9g\u00e9sg\u00e1tl\u00f3 fokozat<\/th>\n<th>V\u00e9delmi szint<\/th>\n<\/tr>\n<tr>\n<td>M03*0.5<\/td>\n<td>Alum\u00ednium\u00f6tv\u00f6zet \/ Rozsdamentes ac\u00e9l \/ Nikkel bevonat\u00fa s\u00e1rgar\u00e9z<\/td>\n<td>&gt;35 ml\/perc<\/td>\n<td>P=7Kpa<\/td>\n<td>3<\/td>\n<td>5<\/td>\n<td>UL94-V0<\/td>\n<td>IP65-IP68<\/td>\n<\/tr>\n<tr>\n<td>M04*0.7<\/td>\n<td>Alum\u00ednium\u00f6tv\u00f6zet \/ Rozsdamentes ac\u00e9l \/ Nikkel bevonat\u00fa s\u00e1rgar\u00e9z<\/td>\n<td>&gt;450 ml\/perc<\/td>\n<td>P=7Kpa<\/td>\n<td>5-7<\/td>\n<td>7-10<\/td>\n<td>UL94-V0<\/td>\n<td>IP65-IP68<\/td>\n<\/tr>\n<tr>\n<td>M05*0.8<\/td>\n<td>Alum\u00ednium\u00f6tv\u00f6zet \/ Rozsdamentes ac\u00e9l \/ Nikkel bevonat\u00fa s\u00e1rgar\u00e9z<\/td>\n<td>&gt;500 ml\/perc<\/td>\n<td>P=7Kpa<\/td>\n<td>5-8.3<\/td>\n<td>8-10<\/td>\n<td>UL94-V0<\/td>\n<td>IP65-IP68<\/td>\n<\/tr>\n<tr>\n<td>M06*1.0<\/td>\n<td>Alum\u00ednium\u00f6tv\u00f6zet \/ Rozsdamentes ac\u00e9l \/ Nikkel bevonat\u00fa s\u00e1rgar\u00e9z<\/td>\n<td>&gt;800 ml\/perc<\/td>\n<td>P=7Kpa<\/td>\n<td>5-7<\/td>\n<td>8-10<\/td>\n<td>UL94-V0<\/td>\n<td>IP65-IP68<\/td>\n<\/tr>\n<tr>\n<td>M08*1.0<\/td>\n<td>Alum\u00ednium\u00f6tv\u00f6zet \/ Rozsdamentes ac\u00e9l \/ Nikkel bevonat\u00fa s\u00e1rgar\u00e9z<\/td>\n<td>&gt;1000 ml\/perc<\/td>\n<td>P=7Kpa<\/td>\n<td>6<\/td>\n<td>10-12<\/td>\n<td>UL94-V0<\/td>\n<td>IP65-IP68<\/td>\n<\/tr>\n<tr>\n<td>M08*1.25<\/td>\n<td>Alum\u00ednium\u00f6tv\u00f6zet \/ Rozsdamentes ac\u00e9l \/ Nikkel bevonat\u00fa s\u00e1rgar\u00e9z<\/td>\n<td>&gt;1200 ml\/perc<\/td>\n<td>P=7Kpa<\/td>\n<td>7<\/td>\n<td>12<\/td>\n<td>UL94-V0<\/td>\n<td>IP65-IP68<\/td>\n<\/tr>\n<tr>\n<td>M12*1.5<\/td>\n<td>Alum\u00ednium\u00f6tv\u00f6zet \/ Rozsdamentes ac\u00e9l \/ Nikkel bevonat\u00fa s\u00e1rgar\u00e9z<\/td>\n<td>&gt;2000 ml\/perc<\/td>\n<td>P=7Kpa<\/td>\n<td>5-10<\/td>\n<td>16-17<\/td>\n<td>UL94-V0<\/td>\n<td>IP65-IP68<\/td>\n<\/tr>\n<tr>\n<td>M16*1.5<\/td>\n<td>Alum\u00ednium\u00f6tv\u00f6zet \/ Rozsdamentes ac\u00e9l \/ Nikkel bevonat\u00fa s\u00e1rgar\u00e9z<\/td>\n<td>&gt;3800 ml\/perc<\/td>\n<td>P=7Kpa<\/td>\n<td>10<\/td>\n<td>20<\/td>\n<td>UL94-V0<\/td>\n<td>IP65-IP68<\/td>\n<\/tr>\n<tr>\n<td>NPT1\/4<\/td>\n<td>Alum\u00ednium\u00f6tv\u00f6zet<\/td>\n<td>&gt;2150 ml\/perc<\/td>\n<td>P=7Kpa<\/td>\n<td>7<\/td>\n<td>15<\/td>\n<td>UL94-V0<\/td>\n<td>IP65-IP68<\/td>\n<\/tr>\n<tr>\n<td>NPT1\/8<\/td>\n<td>Alum\u00ednium\u00f6tv\u00f6zet<\/td>\n<td>&gt;700 ml\/perc<\/td>\n<td>P=7Kpa<\/td>\n<td>7<\/td>\n<td>12<\/td>\n<td>UL94-V0<\/td>\n<td>IP65-IP68<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<div>Menet : metrikus, PG, G (PF) \u00e9s NPT menetek<\/div>\n<div>V\u00e9detts\u00e9gi fok: IP65-IP68 (O-gy\u0171r\u0171vel)<\/div>\n<div>\u00dczemi h\u0151m\u00e9rs\u00e9klet: -40 \u2103 \u00e9s 125 \u2103 k\u00f6z\u00f6tt<\/div>\n<div>Anyagok: Alum\u00ednium\u00f6tv\u00f6zet<\/div>\n<div>L\u00e9g\u00e1tereszt\u0151 k\u00e9pess\u00e9g: 2200 ml\/perc (dp=70 mbar)<\/div>\n<div>V\u00edzbel\u00e9p\u00e9si nyom\u00e1s: &gt;10 kPa (kb. 1 m\u00e9ter v\u00edznyom\u00e1s)<\/div>\n<div>S\u00f3permet-\u00e1ll\u00f3s\u00e1g: 96 \u00f3ra (IEC 68-2-11)<\/div>","protected":false},"featured_media":12009,"comment_status":"closed","ping_status":"closed","template":"","meta":{"inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[],"product_cat":[190],"product_tag":[],"class_list":{"0":"post-12008","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-breather-vent-plug","7":"desktop-align-left","8":"tablet-align-left","9":"mobile-align-left","11":"first","12":"instock","13":"shipping-taxable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/test.viox.com\/hu\/wp-json\/wp\/v2\/product\/12008","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/test.viox.com\/hu\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/test.viox.com\/hu\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/test.viox.com\/hu\/wp-json\/wp\/v2\/comments?post=12008"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/test.viox.com\/hu\/wp-json\/wp\/v2\/media\/12009"}],"wp:attachment":[{"href":"https:\/\/test.viox.com\/hu\/wp-json\/wp\/v2\/media?parent=12008"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/test.viox.com\/hu\/wp-json\/wp\/v2\/product_brand?post=12008"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/test.viox.com\/hu\/wp-json\/wp\/v2\/product_cat?post=12008"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/test.viox.com\/hu\/wp-json\/wp\/v2\/product_tag?post=12008"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}