{"id":11960,"date":"2024-12-26T22:35:16","date_gmt":"2024-12-26T14:35:16","guid":{"rendered":"https:\/\/viox.com\/?post_type=product&#038;p=11960"},"modified":"2024-12-26T22:35:16","modified_gmt":"2024-12-26T14:35:16","slug":"metal-breather-vent-plug","status":"publish","type":"product","link":"https:\/\/test.viox.com\/hu\/termek\/metal-breather-vent-plug\/","title":{"rendered":"F\u00e9m l\u00e9gtelen\u00edt\u0151 szell\u0151z\u0151dug\u00f3"},"content":{"rendered":"<div class=\"product-intro\">\n<h2>F\u00e9m l\u00e9gtelen\u00edt\u0151 szell\u0151z\u0151dug\u00f3<\/h2>\n<h2>M\u0171szaki param\u00e9terek<\/h2>\n<p>A VIOX f\u00e9m szell\u0151z\u0151 dug\u00f3t \u00fagy tervezt\u00e9k, hogy fenntartsa a nyom\u00e1segyens\u00falyt \u00e9s megakad\u00e1lyozza a p\u00e1ralecsap\u00f3d\u00e1st k\u00fclt\u00e9ri vil\u00e1g\u00edt\u00e1sban \u00e9s szekr\u00e9nyekben. Robusztus kialak\u00edt\u00e1s\u00fa, kiv\u00e1l\u00f3 min\u0151s\u00e9g\u0171 anyagokkal, hogy biztos\u00edtsa a tart\u00f3ss\u00e1got \u00e9s a megb\u00edzhat\u00f3s\u00e1got a k\u00fcl\u00f6nb\u00f6z\u0151 ipari alkalmaz\u00e1sokban.<\/p>\n<h2>M\u0171szaki adatok<\/h2>\n<table>\n<tbody>\n<tr>\n<th>T\u00e9tel<\/th>\n<th>R\u00e9szletek<\/th>\n<\/tr>\n<tr>\n<td>Sz\u00e1l<\/td>\n<td>Metrikus, PG, G (PF), \u00e9s NPT<\/td>\n<\/tr>\n<tr>\n<td>V\u00e9delmi fokozat<\/td>\n<td>IP67-IP68 (O-gy\u0171r\u0171vel)<\/td>\n<\/tr>\n<tr>\n<td>Munkah\u0151m\u00e9rs\u00e9klet<\/td>\n<td>-40\u2103 \u00e9s 250\u2103 k\u00f6z\u00f6tt<\/td>\n<\/tr>\n<tr>\n<td>Anyagok<\/td>\n<td>ePTFE a l\u00e9g\u00e1tereszt\u0151 membr\u00e1nhoz, nikkelezett s\u00e1rgar\u00e9z a f\u0151testhez \u00e9s az anyar\u00e9szekhez, magas h\u0151m\u00e9rs\u00e9kletnek ellen\u00e1ll\u00f3 szilikon az O-gy\u0171r\u0171h\u00f6z<\/td>\n<\/tr>\n<tr>\n<td>L\u00e9g\u00e1raml\u00e1s<\/td>\n<td>0,2 ml-t\u0151l 12 l-ig \u00f3r\u00e1nk\u00e9nt 7 kPa-n\u00e1l<\/td>\n<\/tr>\n<tr>\n<td>V\u00edzbehatol\u00e1si nyom\u00e1s<\/td>\n<td>5 bar<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Jellemz\u0151k<\/h2>\n<ul>\n<li>Lehet\u0151v\u00e9 teszi a leveg\u0151 \u00e1thalad\u00e1s\u00e1t, mik\u00f6zben megakad\u00e1lyozza a nedvess\u00e9g \u00e9s a por bejut\u00e1s\u00e1t.<\/li>\n<li>Fenntartja a nyom\u00e1segyens\u00falyt \u00e9s elker\u00fcli a kondenz\u00e1ci\u00f3t a burkolatokban.<\/li>\n<li>Testre szabhat\u00f3 v\u00edz\u00e1ll\u00f3s\u00e1gi szint a v\u00edzm\u00e9lys\u00e9g \u00e9s a l\u00e9g\u00e1tereszt\u0151 k\u00e9pess\u00e9g alapj\u00e1n.<\/li>\n<li>Ide\u00e1lis vesz\u00e9lyes ter\u00fcleteken, robban\u00e1sbiztos elektromos berendez\u00e9sekhez, vegyiparban, k\u0151olajiparban, valamint a villamosipar, k\u00f6nny\u0171ipar \u00e9s g\u00e9pipar k\u00fcl\u00f6nb\u00f6z\u0151 \u00e1gazataiban.<\/li>\n<\/ul>\n<h2>Term\u00e9k le\u00edr\u00e1sa<\/h2>\n<p>A VIOX f\u00e9m szell\u0151z\u0151 dug\u00f3 egy sokoldal\u00fa eszk\u00f6z, amelyet a g\u00e1z \u00e9s folyad\u00e9k \u00e1raml\u00e1s\u00e1nak szab\u00e1lyoz\u00e1s\u00e1ra terveztek. Tart\u00f3s h\u00e9jb\u00f3l, rug\u00f3s lemezekb\u0151l \u00e9s l\u00e9legz\u0151 anyagokb\u00f3l \u00e1ll, \u00edgy alkalmas g\u00e1zok vagy folyad\u00e9kok szab\u00e1lyoz\u00e1s\u00e1ra, kiegyens\u00falyoz\u00e1s\u00e1ra \u00e9s kibocs\u00e1t\u00e1s\u00e1ra cs\u0151vezet\u00e9kekben \u00e9s tart\u00e1lyokban. A h\u00e9j kiv\u00e1l\u00f3 min\u0151s\u00e9g\u0171 alum\u00ednium\u00f6tv\u00f6zetb\u0151l vagy nikkelezett s\u00e1rgar\u00e9zb\u0151l k\u00e9sz\u00fcl, amely kiv\u00e1l\u00f3 korr\u00f3zi\u00f3\u00e1ll\u00f3s\u00e1got \u00e9s szil\u00e1rds\u00e1got biztos\u00edt. A rug\u00f3s lemez, amely nagy rugalmass\u00e1g\u00fa \u00f6tv\u00f6zet anyagb\u00f3l k\u00e9sz\u00fcl, j\u00f3 rugalmass\u00e1got \u00e9s t\u00f6m\u00edtetts\u00e9get biztos\u00edt, lehet\u0151v\u00e9 t\u00e9ve a gyors \u00e9s pontos nyom\u00e1sbe\u00e1ll\u00edt\u00e1sokat. A l\u00e9legz\u0151 anyagok, bele\u00e9rtve a kiv\u00e1l\u00f3 min\u0151s\u00e9g\u0171 h\u00e1l\u00f3s lemezeket, a k\u00fcl\u00f6nb\u00f6z\u0151 folyad\u00e9kjellemz\u0151k alapj\u00e1n optimaliz\u00e1lhat\u00f3k a szell\u0151z\u00e9s \u00e9rdek\u00e9ben.<\/p>\n<h2>El\u0151ny\u00f6k<\/h2>\n<ul>\n<li><strong>Nagy megb\u00edzhat\u00f3s\u00e1g:<\/strong> \u00c9p\u00edtett nagy szil\u00e1rds\u00e1g\u00fa anyagok kiv\u00e1l\u00f3 korr\u00f3zi\u00f3, t\u00f6m\u00f6r\u00edt\u00e9s, illetve kop\u00e1s\u00e1ll\u00f3s\u00e1g, biztos\u00edtva a hossz\u00fa t\u00e1v\u00fa stabil m\u0171k\u00f6d\u00e9s.<\/li>\n<li><strong>K\u00f6nnyen haszn\u00e1lhat\u00f3:<\/strong> Egyszer\u0171 szerkezet, kis m\u00e9ret \u00e9s k\u00f6nny\u0171 telep\u00edt\u00e9s. A bels\u0151 l\u00e9legz\u0151 anyag sz\u00fcks\u00e9g szerint cser\u00e9lhet\u0151 a rugalmas alkalmaz\u00e1s \u00e9rdek\u00e9ben.<\/li>\n<li><strong>Sz\u00e9lesk\u00f6r\u0171 alkalmazhat\u00f3s\u00e1g:<\/strong> Alkalmas k\u00fcl\u00f6nb\u00f6z\u0151 k\u00f6zegek sz\u00e1ll\u00edt\u00e1s\u00e1ra \u00e9s k\u00fcl\u00f6nb\u00f6z\u0151 nyom\u00e1s-, \u00e1raml\u00e1si sebess\u00e9g- \u00e9s h\u0151m\u00e9rs\u00e9klet-tartom\u00e1nyokra. M\u00e1s cs\u0151vezet\u00e9kekkel vagy berendez\u00e9sekkel egy\u00fctt haszn\u00e1lhat\u00f3 stabil \u00e1raml\u00e1si rendszer kialak\u00edt\u00e1s\u00e1hoz.<\/li>\n<\/ul>\n<h2>M\u0171szaki adatlap<\/h2>\n<table>\n<tbody>\n<tr>\n<th>Sz\u00e1l<\/th>\n<th>Menet O.D. (mm)<\/th>\n<th>Menethossz (mm)<\/th>\n<th>Test anyaga<\/th>\n<th>Leveg\u0151\u00e1tereszt\u0151 k\u00e9pess\u00e9g<\/th>\n<th>Oleof\u00f3b fokozat<\/th>\n<\/tr>\n<tr>\n<td>M5*0.8<\/td>\n<td>5<\/td>\n<td>6<\/td>\n<td>S\u00e1rgar\u00e9z<\/td>\n<td>&gt;500 ml\/perc 7 kPa-n\u00e1l<\/td>\n<td>8<\/td>\n<\/tr>\n<tr>\n<td>M6*1.0<\/td>\n<td>6<\/td>\n<td>6<\/td>\n<td>S\u00e1rgar\u00e9z<\/td>\n<td>&gt;800 ml\/perc 7 kPa-n\u00e1l<\/td>\n<td>8<\/td>\n<\/tr>\n<tr>\n<td>M8*1.0<\/td>\n<td>8<\/td>\n<td>7<\/td>\n<td>S\u00e1rgar\u00e9z<\/td>\n<td>&gt;1000 ml\/perc 7 kPa-n\u00e1l<\/td>\n<td>8<\/td>\n<\/tr>\n<tr>\n<td>M8*1.25<\/td>\n<td>8<\/td>\n<td>7<\/td>\n<td>S\u00e1rgar\u00e9z<\/td>\n<td>&gt;1200ml\/min 7kpa nyom\u00e1son<\/td>\n<td>8<\/td>\n<\/tr>\n<tr>\n<td>M12*1.5<\/td>\n<td>12<\/td>\n<td>8<\/td>\n<td>S\u00e1rgar\u00e9z<\/td>\n<td>&gt;2000 ml\/perc 7 kPa-n\u00e1l<\/td>\n<td>8<\/td>\n<\/tr>\n<tr>\n<td>M16*1.5<\/td>\n<td>16<\/td>\n<td>8<\/td>\n<td>S\u00e1rgar\u00e9z<\/td>\n<td>&gt;3800 ml\/perc 7 kPa-n\u00e1l<\/td>\n<td>8<\/td>\n<\/tr>\n<tr>\n<td>M20*1.5<\/td>\n<td>20<\/td>\n<td>8<\/td>\n<td>S\u00e1rgar\u00e9z<\/td>\n<td>&gt;5000 ml\/perc 7 kPa-n\u00e1l<\/td>\n<td>8<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Alkalmaz\u00e1sok<\/h2>\n<p>A VIOX f\u00e9m szell\u0151z\u0151 dug\u00f3t sz\u00e9les k\u00f6rben haszn\u00e1lj\u00e1k olyan ipar\u00e1gakban, mint a vegyipar, a koh\u00e1szat, a rep\u00fcl\u00e9s \u00e9s a hadipar. Ide\u00e1lis g\u00e1zok vagy folyad\u00e9kok szab\u00e1lyoz\u00e1s\u00e1ra, kiegyens\u00falyoz\u00e1s\u00e1ra \u00e9s kibocs\u00e1t\u00e1s\u00e1ra cs\u0151vezet\u00e9kekben \u00e9s tart\u00e1lyokban, biztos\u00edtva a stabil \u00e9s biztons\u00e1gos m\u0171k\u00f6d\u00e9st a k\u00fcl\u00f6nb\u00f6z\u0151 ipari ter\u00fcleteken.<\/p>\n<p>&nbsp;<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<div>Menet: metrikus, PG, G (PF) \u00e9s NPT menetek<\/div>\n<div>V\u00e9detts\u00e9gi fokozat: IP67-IP68 (O-gy\u0171r\u0171vel)<\/div>\n<div>\u00dczemi h\u0151m\u00e9rs\u00e9klet: -40\u2103 \u00e9s 250\u2103 k\u00f6z\u00f6tt<\/div>\n<div>Anyagok: ePTFE a l\u00e9g\u00e1tereszt\u0151 membr\u00e1nhoz, nikkelezett s\u00e1rgar\u00e9z a f\u0151testhez \u00e9s az anya r\u00e9szekhez, magas h\u0151m\u00e9rs\u00e9kletnek ellen\u00e1ll\u00f3 szilikon az O-gy\u0171r\u0171h\u00f6z.<\/div>\n<div>L\u00e9g\u00e1raml\u00e1s: 0,2 ml-t\u0151l 12 l-ig \u00f3r\u00e1nk\u00e9nt 7 kPa-n\u00e1l<\/div>\n<div>V\u00edzbehatol\u00e1si nyom\u00e1s: 5 bar<\/div>","protected":false},"featured_media":11961,"comment_status":"closed","ping_status":"closed","template":"","meta":{"inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[],"product_cat":[190],"product_tag":[],"class_list":{"0":"post-11960","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-breather-vent-plug","7":"desktop-align-left","8":"tablet-align-left","9":"mobile-align-left","11":"first","12":"instock","13":"shipping-taxable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/test.viox.com\/hu\/wp-json\/wp\/v2\/product\/11960","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/test.viox.com\/hu\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/test.viox.com\/hu\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/test.viox.com\/hu\/wp-json\/wp\/v2\/comments?post=11960"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/test.viox.com\/hu\/wp-json\/wp\/v2\/media\/11961"}],"wp:attachment":[{"href":"https:\/\/test.viox.com\/hu\/wp-json\/wp\/v2\/media?parent=11960"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/test.viox.com\/hu\/wp-json\/wp\/v2\/product_brand?post=11960"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/test.viox.com\/hu\/wp-json\/wp\/v2\/product_cat?post=11960"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/test.viox.com\/hu\/wp-json\/wp\/v2\/product_tag?post=11960"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}