{"id":20573,"date":"2025-12-17T08:12:32","date_gmt":"2025-12-17T00:12:32","guid":{"rendered":"https:\/\/viox.com\/?p=20573"},"modified":"2025-12-04T23:48:44","modified_gmt":"2025-12-04T15:48:44","slug":"standard-breaker-sizes","status":"publish","type":"post","link":"https:\/\/test.viox.com\/hu\/standard-breaker-sizes\/","title":{"rendered":"Szabv\u00e1nyos megszak\u00edt\u00f3 m\u00e9retek: MCCB \u00e1ramer\u0151ss\u00e9g tartom\u00e1ny 16A-t\u0151l 1600A-ig"},"content":{"rendered":"<div class=\"product-intro\">\n<p>A megfelel\u0151 kiv\u00e1laszt\u00e1sa<a href=\"https:\/\/test.viox.com\/hu\/mccb\/\"> m\u0171anyagh\u00e1zas megszak\u00edt\u00f3 (MCCB)<\/a> a szabv\u00e1nyos megszak\u00edt\u00f3 m\u00e9retek meg\u00e9rt\u00e9s\u00e9vel kezd\u0151dik. Elt\u00e9r\u0151en a <a href=\"http:\/\/voix.com\/mcb\" rel=\"nofollow noopener\" target=\"_blank\">miniat\u0171r megszak\u00edt\u00f3k (MCB-k)<\/a> v\u00e9gs\u0151 \u00e1ramk\u00f6r\u00f6ket v\u00e9d\u0151 megszak\u00edt\u00f3kt\u00f3l, az MCCB-k sokkal sz\u00e9lesebb \u00e1ramtartom\u00e1nyt fednek le \u2013 a 16A-es \u00e1gvezet\u00e9kt\u0151l az 1600A-es f\u0151 bet\u00e1pl\u00e1l\u00e1sig \u2013, \u00e9s a megfelel\u0151 n\u00e9vleges \u00e9rt\u00e9k kiv\u00e1laszt\u00e1sa k\u00f6zvetlen\u00fcl befoly\u00e1solja a rendszer biztons\u00e1g\u00e1t, koordin\u00e1ci\u00f3j\u00e1t \u00e9s a projekt k\u00f6lts\u00e9geit.<\/p>\n<p>Ez az \u00fatmutat\u00f3 felt\u00e9rk\u00e9pezi a teljes IEC 60947-2 szabv\u00e1nyos \u00e1ram\u00e9rt\u00e9keket, elmagyar\u00e1zza a keretm\u00e9ret-kateg\u00f3ri\u00e1kat, \u00e9s megmutatja, hogyan illesztheti a megszak\u00edt\u00f3 specifik\u00e1ci\u00f3it az alkalmaz\u00e1s\u00e1hoz. Ak\u00e1r egy motor t\u00e1pvezet\u00e9k\u00e9t, egy \u00e9p\u00fclet al-eloszt\u00f3j\u00e1t vagy egy kapcsol\u00f3berendez\u00e9s bet\u00e1pl\u00e1l\u00e1s\u00e1t m\u00e9retezi, megtal\u00e1lja a sz\u00fcks\u00e9ges m\u0171szaki r\u00e9szleteket \u00e9s kiv\u00e1laszt\u00e1si logik\u00e1t.<\/p>\n<h2>Gyors referencia: Szabv\u00e1nyos MCCB \u00e1ram\u00e9rt\u00e9kek<\/h2>\n<p>Az IEC-nek megfelel\u0151 MCCB-k a k\u00f6vetkez\u0151 szabv\u00e1nyos \u00e9rt\u00e9kekkel kaphat\u00f3k:<\/p>\n<p><strong>16A<\/strong> | <strong>20A<\/strong> | <strong>25A<\/strong> | <strong>32A<\/strong> | <strong>40A<\/strong> | <strong>50A<\/strong> | <strong>63A<\/strong> | <strong>80A<\/strong> | <strong>100A<\/strong> | <strong>125A<\/strong> | <strong>160A<\/strong> | <strong>200A<\/strong> | <strong>250A<\/strong> | <strong>320A<\/strong> | <strong>400A<\/strong> | <strong>500A<\/strong> | <strong>630A<\/strong> | <strong>800A<\/strong> | <strong>1000A<\/strong> | <strong>1250A<\/strong> | <strong>1600A<\/strong><\/p>\n<p>Nem minden gy\u00e1rt\u00f3 k\u00edn\u00e1l minden keretben minden n\u00e9vleges \u00e9rt\u00e9ket. A keretm\u00e9ret (kicsi, k\u00f6zepes vagy nagy) hat\u00e1rozza meg, hogy mely \u00e1ram\u00e9rt\u00e9kek \u00e1llnak rendelkez\u00e9sre, \u00e9s milyen megszak\u00edt\u00f3k\u00e9pess\u00e9geket (Icu\/Ics) \u00e9rhet el a megszak\u00edt\u00f3.<\/p>\n<figure><img decoding=\"async\" src=\"https:\/\/img.viox.com\/mccb-frame-size-comparison-showing-small-medium-and-large-frame-breakers.webp\" alt=\"MCCB Frame Size Comparison showing small, medium, and large frame breakers\" \/><figcaption>1. \u00e1bra: Az MCCB-k fizikai m\u00e9ret\u00e9nek v\u00e1ltoz\u00e1sa a keretkateg\u00f3ri\u00e1kban. Balr\u00f3l jobbra: Kicsi keret (63A), K\u00f6zepes keret (400A), Nagy keret (1600A). A keretm\u00e9ret hat\u00e1rozza meg a maxim\u00e1lis \u00e1ram\u00e9rt\u00e9ket \u00e9s a rendelkez\u00e9sre \u00e1ll\u00f3 megszak\u00edt\u00f3k\u00e9pess\u00e9get.<\/figcaption><\/figure>\n<h2>Az IEC 60947-2 szabv\u00e1nyos \u00e9rt\u00e9kek meg\u00e9rt\u00e9se<\/h2>\n<p>Az IEC 60947-2 az a nemzetk\u00f6zi szabv\u00e1ny, amely meghat\u00e1rozza a kisfesz\u00fclts\u00e9g\u0171 megszak\u00edt\u00f3kra vonatkoz\u00f3 teljes\u00edtm\u00e9nyk\u00f6vetelm\u00e9nyeket, bele\u00e9rtve az \u00f6sszes MCCB-t is. Ha egy megszak\u00edt\u00f3 adatt\u00e1bl\u00e1j\u00e1n az \u201cIEC 60947-2\u201d jel\u00f6l\u00e9st l\u00e1tja, az meger\u0151s\u00edti, hogy az eszk\u00f6zt tesztelt\u00e9k \u00e9s tan\u00fas\u00edtott\u00e1k, hogy megfelel a meghat\u00e1rozott elektromos, mechanikai \u00e9s biztons\u00e1gi krit\u00e9riumoknak.<\/p>\n<h3>F\u0151bb n\u00e9vleges param\u00e9terek<\/h3>\n<p>Minden MCCB adatlap tartalmazza ezeket a l\u00e9nyeges \u00e9rt\u00e9keket:<\/p>\n<p><strong>In (N\u00e9vleges \u00e1ram)<\/strong>: A maxim\u00e1lis folyamatos \u00e1ram, amelyet a megszak\u00edt\u00f3 egy referencia k\u00f6rnyezeti h\u0151m\u00e9rs\u00e9kleten (\u00e1ltal\u00e1ban 40\u00b0C) k\u00e9pes vezetni kiold\u00e1s n\u00e9lk\u00fcl. Ez a megszak\u00edt\u00f3 \u201cm\u00e9rete\u201d - p\u00e9ld\u00e1ul egy 250A-es MCCB In = 250A.<\/p>\n<p><strong>Ue (N\u00e9vleges \u00fczemi fesz\u00fclts\u00e9g)<\/strong>: Az a fesz\u00fclts\u00e9g, amelyen a megszak\u00edt\u00f3t \u00fczemeltet\u00e9sre tervezt\u00e9k. A szok\u00e1sos \u00e9rt\u00e9kek k\u00f6z\u00e9 tartozik a 230V, 400V, 690V AC h\u00e1romf\u00e1zis\u00fa rendszerekhez, vagy a 250V DC akkumul\u00e1toros \u00e9s napelemes alkalmaz\u00e1sokhoz.<\/p>\n<p><strong>Icu (N\u00e9vleges v\u00e9gs\u0151 r\u00f6vidz\u00e1rlati megszak\u00edt\u00f3k\u00e9pess\u00e9g)<\/strong>: A maxim\u00e1lis hiba\u00e1ram (kA-ban), amelyet a megszak\u00edt\u00f3 egyszer biztons\u00e1gosan meg tud szak\u00edtani. Egy Icu szint\u0171 hiba ut\u00e1n a megszak\u00edt\u00f3 nem felt\u00e9tlen\u00fcl alkalmas a tov\u00e1bbi haszn\u00e1latra. A tipikus \u00e9rt\u00e9kek 25kA \u00e9s 100kA k\u00f6z\u00f6tt mozognak a keretm\u00e9rett\u0151l f\u00fcgg\u0151en.<\/p>\n<p><strong>Ics (N\u00e9vleges \u00fczemi r\u00f6vidz\u00e1rlati megszak\u00edt\u00f3k\u00e9pess\u00e9g)<\/strong>: Az a hiba\u00e1ramszint, amelyn\u00e9l a megszak\u00edt\u00f3 k\u00e9pes megszak\u00edtani \u00e9s tov\u00e1bbra is haszn\u00e1lhat\u00f3 marad a folyamatos m\u0171k\u00f6d\u00e9shez. Az IEC az Ics-t az Icu sz\u00e1zal\u00e9k\u00e1ban hat\u00e1rozza meg - \u00e1ltal\u00e1ban 25%, 50%, 75% vagy 100%. Kritikus l\u00e9tes\u00edtm\u00e9nyekn\u00e9l az Ics = 100%-ot kell megadni; kereskedelmi \u00e9p\u00fcletekn\u00e9l a 75% a bevett gyakorlat.<\/p>\n<h3>Felhaszn\u00e1l\u00e1si kateg\u00f3ri\u00e1k<\/h3>\n<p>Az IEC 60947-2 k\u00e9t kateg\u00f3ri\u00e1t hat\u00e1roz meg:<\/p>\n<ul>\n<li><strong>A kateg\u00f3ria<\/strong>: Azonnali kiold\u00e1sra tervezett megszak\u00edt\u00f3k, sz\u00e1nd\u00e9kos id\u0151z\u00edt\u00e9s n\u00e9lk\u00fcl. A legt\u00f6bb MCCB ebbe a kateg\u00f3ri\u00e1ba tartozik az \u00e1ltal\u00e1nos eloszt\u00e1s \u00e9s a motorv\u00e9delem szempontj\u00e1b\u00f3l.<\/li>\n<li><strong>B kateg\u00f3ria<\/strong>: Megszak\u00edt\u00f3k sz\u00e1nd\u00e9kos id\u0151z\u00edt\u00e9ssel (ellen\u00e1ll\u00e1si k\u00e9pess\u00e9ggel) a downstream eszk\u00f6z\u00f6kkel val\u00f3 szelekt\u00edv koordin\u00e1ci\u00f3hoz. Olyan upstream poz\u00edci\u00f3kban haszn\u00e1lj\u00e1k, ahol szelektivit\u00e1sra van sz\u00fcks\u00e9g.<\/li>\n<\/ul>\n<h3>Mi\u00e9rt fontosak ezek az \u00e9rt\u00e9kek<\/h3>\n<p>Az MCCB m\u00e9retez\u00e9sekor meg kell gy\u0151z\u0151dnie arr\u00f3l, hogy:<\/p>\n<ul>\n<li>Az In megegyezik vagy meghaladja a terhel\u00e9si \u00e1ramot (a bekapcsol\u00e1si \u00e1ram \u00e9s a j\u00f6v\u0151beli n\u00f6veked\u00e9s figyelembev\u00e9tel\u00e9vel)<\/li>\n<li>Az Icu el\u00e9ri vagy meghaladja a v\u00e1rhat\u00f3 hiba\u00e1ramot a telep\u00edt\u00e9si ponton<\/li>\n<li>Az Ics megfelel\u0151 az alkalmaz\u00e1s kritikus fontoss\u00e1g\u00e1hoz (75-100%)<\/li>\n<li>A keretm\u00e9ret megfelel a sz\u00fcks\u00e9ges In \u00e9s Icu kombin\u00e1ci\u00f3nak<\/li>\n<\/ul>\n<p>Egy 250A-es terhel\u00e9s nem felt\u00e9tlen\u00fcl ig\u00e9nyel 250A-es megszak\u00edt\u00f3t - ellen\u0151riznie kell a hiba szintj\u00e9t, a koordin\u00e1ci\u00f3s k\u00f6vetelm\u00e9nyeket, \u00e9s azt, hogy alkalmazhat\u00f3-e a teljes\u00edtm\u00e9nycs\u00f6kkent\u00e9s (magas k\u00f6rnyezeti h\u0151m\u00e9rs\u00e9klet, csoportos\u00edt\u00e1s vagy harmonikus tartalom).<\/p>\n<h2>MCCB keretm\u00e9ret kateg\u00f3ri\u00e1k<\/h2>\n<h3>Keretm\u00e9ret szerinti oszt\u00e1lyoz\u00e1s<\/h3>\n<p>B\u00e1r a gy\u00e1rt\u00f3k k\u00fcl\u00f6nb\u00f6z\u0151 elnevez\u00e9seket haszn\u00e1lnak, az ipar\u00e1g h\u00e1rom sz\u00e9les kateg\u00f3ri\u00e1t ismer el:<\/p>\n<table>\n<tbody>\n<tr>\n<td><strong>Keret kateg\u00f3ria<\/strong><\/td>\n<td><strong>Tipikus \u00e1ramtartom\u00e1ny<\/strong><\/td>\n<td><strong>Tipikus Icu tartom\u00e1ny<\/strong><\/td>\n<td><strong>Gyakori alkalmaz\u00e1sok<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>Kicsi keret<\/strong><\/td>\n<td>16A \u2013 250A<\/td>\n<td>25kA \u2013 50kA<\/td>\n<td>\u00c1g\u00e1ramk\u00f6r\u00f6k, kis t\u00e1pvezet\u00e9kek, motorv\u00e9delem<\/td>\n<\/tr>\n<tr>\n<td><strong>K\u00f6zepes keret<\/strong><\/td>\n<td>250A \u2013 630A<\/td>\n<td>35kA \u2013 70kA<\/td>\n<td>Al-eloszt\u00f3k, \u00e9p\u00fclet t\u00e1pvezet\u00e9kek, eloszt\u00f3t\u00e1bl\u00e1k<\/td>\n<\/tr>\n<tr>\n<td><strong>Nagy keret<\/strong><\/td>\n<td>630A \u2013 1600A<\/td>\n<td>50kA \u2013 100kA<\/td>\n<td>F\u0151 bet\u00e1pl\u00e1l\u00e1sok, kapcsol\u00f3berendez\u00e9sek, ipari h\u00e1l\u00f3zatok<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Mi\u00e9rt fontos a keretm\u00e9ret<\/h3>\n<p><strong>Megszak\u00edt\u00f3k\u00e9pess\u00e9g korl\u00e1tai<\/strong>: A nagyobb keretek nagyobb hiba\u00e1ramokat k\u00e9pesek megszak\u00edtani. Ha a telep\u00edt\u00e9si ponton 65kA v\u00e1rhat\u00f3 hiba\u00e1ram van, akkor k\u00f6zepes vagy nagy keretre lesz sz\u00fcks\u00e9ge - a kis keretek \u00e1ltal\u00e1ban 50kA-n\u00e1l tet\u0151znek.<\/p>\n<p><strong>Fizikai hely<\/strong>: Egy 1600A-es nagy keretes MCCB 300 mm sz\u00e9les vagy ann\u00e1l is nagyobb lehet, m\u00edg egy 63A-es kis keretes megszak\u00edt\u00f3 70 mm lehet. A panel tervez\u00e9s\u00e9nek figyelembe kell vennie ezeket a m\u00e9reteket, k\u00fcl\u00f6n\u00f6sen a fel\u00faj\u00edt\u00e1si projektekben.<\/p>\n<p><strong>K\u00f6lts\u00e9goptimaliz\u00e1l\u00e1s<\/strong>: Ne specifik\u00e1ljon t\u00fal. Egy 200A-es alkalmaz\u00e1s 30kA-es hiba\u00e1rammal nem ig\u00e9nyel nagy keretes megszak\u00edt\u00f3t. Haszn\u00e1ljon egy kis keretes 250A-es egys\u00e9get, hogy helyet \u00e9s k\u00f6lts\u00e9get takar\u00edtson meg a panelen.<\/p>\n<p><strong>Be\u00e1ll\u00edt\u00e1si tartom\u00e1ny<\/strong>: A nagyobb keretekben l\u00e9v\u0151 elektronikus kiold\u00f3egys\u00e9gek gyakran lehet\u0151v\u00e9 teszik az In, Ir (termikus) \u00e9s Im (m\u00e1gneses) be\u00e1ll\u00edt\u00e1sok helysz\u00edni be\u00e1ll\u00edt\u00e1s\u00e1t. A termikus-m\u00e1gneses kiold\u00f3kkal rendelkez\u0151 kis keretek \u00e1ltal\u00e1ban r\u00f6gz\u00edtettek.<\/p>\n<h3>Keret vs. N\u00e9vleges \u00e9rt\u00e9k: Gyakorlati p\u00e9lda<\/h3>\n<p>Vegy\u00fcnk egy 400A-es t\u00e1pvezet\u00e9ket egy kereskedelmi \u00e9p\u00fcletben 40kA-es hiba\u00e1rammal:<\/p>\n<ul>\n<li><strong>1. opci\u00f3<\/strong>: V\u00e1lasszon egy k\u00f6zepes keretes MCCB-t 400A \/ 50kA n\u00e9vleges \u00e9rt\u00e9kkel (In=400A, Icu=50kA)<\/li>\n<li><strong>2. opci\u00f3<\/strong>: V\u00e1lasszon egy nagy keretes MCCB-t 400A \/ 65kA n\u00e9vleges \u00e9rt\u00e9kkel (In=400A, Icu=65kA)<\/li>\n<\/ul>\n<p>Mindkett\u0151 megfelel a 400A-es terhel\u00e9si k\u00f6vetelm\u00e9nynek, de az 1. opci\u00f3 egy kisebb, olcs\u00f3bb keretet haszn\u00e1l, amely elegend\u0151 a 40kA-es hiba\u00e1ramhoz. A 2. opci\u00f3 t\u00f6bbletet biztos\u00edt, de pazarl\u00f3 a panel hely \u00e9s a k\u00f6lts\u00e9gvet\u00e9s szempontj\u00e1b\u00f3l. A l\u00e9nyeg az, hogy <strong>a legkisebb keretet v\u00e1lassza<\/strong> ami megfelel mind az In, mind az Icu k\u00f6vetelm\u00e9nyeinek.<\/p>\n<figure><img decoding=\"async\" src=\"https:\/\/img.viox.com\/standard-mccb-current-ratings-chart-organized-by-frame-size.webp\" alt=\"Standard MCCB Current Ratings Chart organized by frame size\" \/><figcaption>2. \u00e1bra: A teljes IEC 60947-2 szabv\u00e1ny szerinti \u00e1ram\u00e9rt\u00e9kek keretkateg\u00f3ri\u00e1k szerint rendezve. A kis keretek (16-250A) \u00e1ramk\u00f6ri \u00e9s motorv\u00e9delmet biztos\u00edtanak; a k\u00f6zepes keretek (250-630A) \u00e9p\u00fclet bet\u00e1pl\u00e1l\u00e1s\u00e1t \u00e9s al-eloszt\u00f3it szolg\u00e1lj\u00e1k; a nagy keretek (630-1600A) a f\u0151 bej\u00f6v\u0151ket \u00e9s a kapcsol\u00f3berendez\u00e9seket v\u00e9dik.<\/figcaption><\/figure>\n<h2>Kis keretes MCCB-k (16A \u2013 250A)<\/h2>\n<p>A kis keretes MCCB-k a legt\u00f6bb \u00e1ramk\u00f6ri, al-bet\u00e1pl\u00e1l\u00e1si \u00e9s motorv\u00e9delmi alkalmaz\u00e1st kezelik kereskedelmi \u00e9s k\u00f6nny\u0171ipari k\u00f6rnyezetben. \u00c1thidalj\u00e1k a szakad\u00e9kot az MCB-k (125A-ig) \u00e9s a nagyobb eloszt\u00f3 megszak\u00edt\u00f3k k\u00f6z\u00f6tt.<\/p>\n<h3>Szabv\u00e1nyos \u00e1ram\u00e9rt\u00e9kek<\/h3>\n<table>\n<tbody>\n<tr>\n<td><strong>\u00c9rt\u00e9k (A)<\/strong><\/td>\n<td><strong>Tipikus alkalmaz\u00e1sok<\/strong><\/td>\n<td><strong>Gyakori kiold\u00e1si t\u00edpus<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>16A<\/strong><\/td>\n<td>Kis motoros bet\u00e1pl\u00e1l\u00f3k, vil\u00e1g\u00edt\u00e1si panelek<\/td>\n<td>Termikus-m\u00e1gneses<\/td>\n<\/tr>\n<tr>\n<td><strong>20A<\/strong><\/td>\n<td>Berendez\u00e9s \u00e1ramk\u00f6rei, kis szivatty\u00fak<\/td>\n<td>Termikus-m\u00e1gneses<\/td>\n<\/tr>\n<tr>\n<td><strong>25A<\/strong><\/td>\n<td>HVAC egys\u00e9gek, kis g\u00e9pek<\/td>\n<td>Termikus-m\u00e1gneses<\/td>\n<\/tr>\n<tr>\n<td><strong>32A<\/strong><\/td>\n<td>Motoros bet\u00e1pl\u00e1l\u00f3k (15kW-ig 400V-on)<\/td>\n<td>Termikus-m\u00e1gneses<\/td>\n<\/tr>\n<tr>\n<td><strong>40A<\/strong><\/td>\n<td>Kereskedelmi konyhai berendez\u00e9sek, h\u0171t\u0151k<\/td>\n<td>Termikus-m\u00e1gneses<\/td>\n<\/tr>\n<tr>\n<td><strong>50A<\/strong><\/td>\n<td>K\u00f6zepes motorok (22kW), UPS bet\u00e1pl\u00e1l\u00f3k<\/td>\n<td>Termikus-m\u00e1gneses<\/td>\n<\/tr>\n<tr>\n<td><strong>63A<\/strong><\/td>\n<td>Eloszt\u00f3 al-bet\u00e1pl\u00e1l\u00f3k, nagy motorok (30kW)<\/td>\n<td>Termikus-m\u00e1gneses \/ Elektronikus<\/td>\n<\/tr>\n<tr>\n<td><strong>80A<\/strong><\/td>\n<td>\u00c9p\u00fclet al-eloszt\u00e1sa, motorvez\u00e9rl\u0151 k\u00f6zpontok<\/td>\n<td>Termikus-m\u00e1gneses \/ Elektronikus<\/td>\n<\/tr>\n<tr>\n<td><strong>100A<\/strong><\/td>\n<td>Emeleti eloszt\u00f3t\u00e1bl\u00e1k, lift \u00e1ramk\u00f6r\u00f6k<\/td>\n<td>Termikus-m\u00e1gneses \/ Elektronikus<\/td>\n<\/tr>\n<tr>\n<td><strong>125A<\/strong><\/td>\n<td>\u00c9p\u00fclet felsz\u00e1ll\u00f3 vezet\u00e9kek, kis kereskedelmi szolg\u00e1ltat\u00f3 bej\u00e1rat<\/td>\n<td>Elektronikus<\/td>\n<\/tr>\n<tr>\n<td><strong>160A<\/strong><\/td>\n<td>Al-eloszt\u00f3k, gener\u00e1tor \u00e1tkapcsol\u00f3k<\/td>\n<td>Elektronikus<\/td>\n<\/tr>\n<tr>\n<td><strong>200A<\/strong><\/td>\n<td>Kereskedelmi al-eloszt\u00f3k, kis ipari bet\u00e1pl\u00e1l\u00f3k<\/td>\n<td>Elektronikus<\/td>\n<\/tr>\n<tr>\n<td><strong>250A<\/strong><\/td>\n<td>\u00c9p\u00fclet f\u0151 bet\u00e1pl\u00e1l\u00f3i, ipari eloszt\u00e1s<\/td>\n<td>Elektronikus<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>M\u0171szaki jellemz\u0151k<\/h3>\n<p><strong>T\u00f6r\u00e9si kapacit\u00e1s<\/strong>: A kis keretes MCCB-k jellemz\u0151en 25kA \u00e9s 50kA k\u00f6z\u00f6tti Icu \u00e9rt\u00e9keket k\u00edn\u00e1lnak. A legt\u00f6bb kereskedelmi \u00e9p\u00fclethez (20-35kA z\u00e1rlati szintek) egy 36kA vagy 50kA keret megfelel\u0151 v\u00e9delmet ny\u00fajt.<\/p>\n<p><strong>Kiold\u00e1si technol\u00f3gia<\/strong>:<\/p>\n<ul>\n<li><strong>16A-63A<\/strong>: \u00c1ltal\u00e1ban r\u00f6gz\u00edtett termikus-m\u00e1gneses (bimet\u00e1l + elektrom\u00e1gneses kiold\u00e1s)<\/li>\n<li><strong>63A-250A<\/strong>: El\u00e9rhet\u0151 mind r\u00f6gz\u00edtett termikus-m\u00e1gneses, mind \u00e1ll\u00edthat\u00f3 elektronikus v\u00e1ltozatban<\/li>\n<li>Az elektronikus kiold\u00f3egys\u00e9gek \u00e1ll\u00edthat\u00f3 Ir (t\u00falterhel\u00e9s) \u00e9s Im (z\u00e1rlat) be\u00e1ll\u00edt\u00e1sokat k\u00edn\u00e1lnak, amelyek hasznosak a motor koordin\u00e1ci\u00f3j\u00e1hoz<\/li>\n<\/ul>\n<p><strong>El\u00e9rhet\u0151 p\u00f3lusok<\/strong>: 1P, 2P, 3P, 4P konfigur\u00e1ci\u00f3k. Vegye figyelembe, hogy az 1P MCCB-k kev\u00e9sb\u00e9 gyakoriak, mint az MCB-k egyf\u00e1zis\u00fa \u00e1ramk\u00f6r\u00f6kh\u00f6z \u2013 a legt\u00f6bb kis keretes MCCB 2P vagy 3P-vel kezd\u0151dik.<\/p>\n<h3>Motorv\u00e9delem p\u00e9lda<\/h3>\n<p>Egy 30kW \/ 400V-os h\u00e1romf\u00e1zis\u00fa motorhoz (In \u2248 57A teljes terhel\u00e9s):<\/p>\n<ol>\n<li><strong>V\u00e1lassza ki a megszak\u00edt\u00f3 \u00e9rt\u00e9k\u00e9t<\/strong>: V\u00e1lasszon 63A MCCB-t (a k\u00f6vetkez\u0151 szabv\u00e1nyos m\u00e9ret 57A felett)<\/li>\n<li><strong>Ellen\u0151rizze a megszak\u00edt\u00e1si k\u00e9pess\u00e9get<\/strong>: Ha a z\u00e1rlati szint 28kA, adja meg a 36kA vagy 50kA Icu-t<\/li>\n<li><strong>Kiold\u00e1si be\u00e1ll\u00edt\u00e1s<\/strong>: Haszn\u00e1ljon elektronikus kiold\u00e1st, \u00e1ll\u00edthat\u00f3 Ir \u00e9rt\u00e9kkel, amelyet 0,95 x In-re \u00e1ll\u00edtson (54A termikus v\u00e9delem)<\/li>\n<li><strong>Koordin\u00e1ci\u00f3<\/strong>: Gy\u0151z\u0151dj\u00f6n meg arr\u00f3l, hogy a m\u00e1gneses k\u00fcsz\u00f6b\u00e9rt\u00e9k Im &gt; motor ind\u00edt\u00f3\u00e1rama (jellemz\u0151en 6-8 x In)<\/li>\n<\/ol>\n<h3>Mikor v\u00e1lasszon kis keretet<\/h3>\n<ul>\n<li><strong>Terhel\u00e9si \u00e1ram<\/strong> \u2264 250A<\/li>\n<li><strong>Z\u00e1rlati szint<\/strong> \u2264 50kA<\/li>\n<li><strong>Alkalmaz\u00e1s<\/strong> motorokat, g\u00e9peket vagy \u00e9p\u00fclet al-eloszt\u00e1s\u00e1t foglalja mag\u00e1ban<\/li>\n<li><strong>Hely<\/strong> korl\u00e1tozott (\u00e1ltal\u00e1ban 70-140 mm sz\u00e9les, a p\u00f3lusokt\u00f3l f\u00fcgg\u0151en)<\/li>\n<\/ul>\n<p>Alacsonyabb \u00e9rt\u00e9kekhez (16-32A), amelyek egyszer\u0171 reziszt\u00edv terhel\u00e9seket v\u00e9denek, egy MCB k\u00f6lts\u00e9ghat\u00e9konyabb lehet. V\u00e1lasszon MCCB-t, ha \u00e1ll\u00edthat\u00f3 kiold\u00e1si be\u00e1ll\u00edt\u00e1sokra, nagyobb megszak\u00edt\u00e1si k\u00e9pess\u00e9gre vagy jobb szelektivit\u00e1si koordin\u00e1ci\u00f3ra van sz\u00fcks\u00e9ge.<\/p>\n<h2>K\u00f6zepes keretes MCCB-k (250A \u2013 630A)<\/h2>\n<p>A k\u00f6zepes keretes MCCB-k a kereskedelmi \u00e9s ipari eloszt\u00f3rendszerek gerinc\u00e9t k\u00e9pezik. V\u00e9dik az \u00e9p\u00fclet bet\u00e1pl\u00e1l\u00f3it, al-eloszt\u00f3it \u00e9s a k\u00f6z\u00e9pfesz\u00fclts\u00e9g\u0171 transzform\u00e1torok szekunder oldal\u00e1t. Ez a tartom\u00e1ny lefedi az irodah\u00e1zakban, bev\u00e1s\u00e1rl\u00f3k\u00f6zpontokban \u00e9s gy\u00e1rt\u00f3\u00fczemekben tal\u00e1lhat\u00f3 f\u0151 eloszt\u00f3t\u00e1bl\u00e1k alkalmaz\u00e1sainak t\u00f6bbs\u00e9g\u00e9t.<\/p>\n<h3>Szabv\u00e1nyos \u00e1ram\u00e9rt\u00e9kek<\/h3>\n<table>\n<tbody>\n<tr>\n<td><strong>\u00c9rt\u00e9k (A)<\/strong><\/td>\n<td><strong>Tipikus alkalmaz\u00e1sok<\/strong><\/td>\n<td><strong>Tipikus Icu tartom\u00e1ny<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>250A<\/strong><\/td>\n<td>\u00c9p\u00fclet f\u0151 bet\u00e1pl\u00e1l\u00f3i, ipari al-eloszt\u00e1s<\/td>\n<td>35kA \u2013 65kA<\/td>\n<\/tr>\n<tr>\n<td><strong>320A<\/strong><\/td>\n<td>Kereskedelmi f\u0151 bet\u00e1pl\u00e1l\u00f3k, k\u00f6zepes ipari terhel\u00e9sek<\/td>\n<td>35kA \u2013 65kA<\/td>\n<\/tr>\n<tr>\n<td><strong>400A<\/strong><\/td>\n<td>\u00c9p\u00fclet szolg\u00e1ltat\u00f3 bej\u00e1rata (kicsi-k\u00f6zepes), technol\u00f3giai berendez\u00e9sek<\/td>\n<td>35kA \u2013 70kA<\/td>\n<\/tr>\n<tr>\n<td><strong>500A<\/strong><\/td>\n<td>Nagy \u00e9p\u00fclet bet\u00e1pl\u00e1l\u00f3k, ipari f\u0151vezet\u00e9kek<\/td>\n<td>50kA \u2013 70kA<\/td>\n<\/tr>\n<tr>\n<td><strong>630A<\/strong><\/td>\n<td>F\u0151 eloszt\u00f3t\u00e1bl\u00e1k, transzform\u00e1tor szekunder v\u00e9delem<\/td>\n<td>50kA \u2013 85kA<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>M\u0171szaki jellemz\u0151k<\/h3>\n<p><strong>T\u00f6r\u00e9si kapacit\u00e1s<\/strong>: A k\u00f6zepes keretek magasabb Icu \u00e9rt\u00e9keket (35-85kA) k\u00edn\u00e1lnak a f\u0151 eloszt\u00e1si pontokon jellemz\u0151 magasabb z\u00e1rlati \u00e1ramok kezel\u00e9s\u00e9re. A helysz\u00edni gener\u00e1torral vagy szoros transzform\u00e1tor csatol\u00e1ssal rendelkez\u0151 ipari telephelyeken gyakran 40-65kA tartom\u00e1nyban vannak a z\u00e1rlati szintek.<\/p>\n<p><strong>Elektronikus \u00dat Egys\u00e9gek<\/strong>: Szinte minden k\u00f6zepes keretes MCCB elektronikus kiold\u00e1si technol\u00f3gi\u00e1t haszn\u00e1l a k\u00f6vetkez\u0151kkel:<\/p>\n<ul>\n<li><strong>Ir (T\u00falterhel\u00e9s)<\/strong>: \u00c1ll\u00edthat\u00f3 0,4 \u00e9s 1,0 x In k\u00f6z\u00f6tt, k\u00e9sleltetett termikus v\u00e9delem<\/li>\n<li><strong>Isd (R\u00f6vid k\u00e9sleltet\u00e9s)<\/strong>: \u00c1ll\u00edthat\u00f3 pillanatnyi r\u00f6vidz\u00e1rlati k\u00fcsz\u00f6b\u00e9rt\u00e9k, tipikusan 1,5-10 x In<\/li>\n<li><strong>Ii (Pillanatnyi)<\/strong>: M\u00e1gneses kiold\u00e1s magas szint\u0171 hib\u00e1khoz (opcion\u00e1lis egyes egys\u00e9geken)<\/li>\n<li><strong>F\u00f6ldz\u00e1rlat<\/strong>: Opcion\u00e1lis f\u00f6ldz\u00e1rlat elleni v\u00e9delmi modul a fokozott biztons\u00e1g \u00e9rdek\u00e9ben<\/li>\n<\/ul>\n<p><strong>Keret Sz\u00e9less\u00e9ge<\/strong>: 3 p\u00f3lus\u00fa egys\u00e9gekn\u00e9l 140-180 mm, 4 p\u00f3lus\u00faakn\u00e1l 190-240 mm sz\u00e9less\u00e9g v\u00e1rhat\u00f3. Gondosan tervezze meg a panel kiv\u00e1g\u00e1si m\u00e9reteit \u2013 ezek a megszak\u00edt\u00f3k l\u00e9nyegesen t\u00f6bb helyet foglalnak el, mint a kis keretek.<\/p>\n<p><strong>Kommunik\u00e1ci\u00f3<\/strong>: Sok k\u00f6zepes keret\u0171 MCCB k\u00edn\u00e1l kommunik\u00e1ci\u00f3s modulokat (Modbus RTU, Profibus, Ethernet) az \u00e9p\u00fcletfel\u00fcgyeleti rendszerekbe (BMS) vagy a SCADA-ba val\u00f3 integr\u00e1l\u00e1shoz.<\/p>\n<h3>Koordin\u00e1ci\u00f3 \u00e9s szelektivit\u00e1s<\/h3>\n<p>Ezen az \u00e1ramszinten, <strong>szelekt\u00edv koordin\u00e1ci\u00f3<\/strong> kritikus fontoss\u00e1g\u00fav\u00e1 v\u00e1lik. Id\u0151-\u00e1ram karakterisztika elemz\u00e9sre van sz\u00fcks\u00e9g annak biztos\u00edt\u00e1s\u00e1hoz, hogy a fels\u0151 oldali 630A-es \u00e9s az als\u00f3 oldali 250A-es megszak\u00edt\u00f3k megfelel\u0151en sz\u00e9tv\u00e1lasszanak:<\/p>\n<ul>\n<li><strong>Haszn\u00e1ljon k\u00fcl\u00f6nb\u00f6z\u0151 kiold\u00e1si technol\u00f3gi\u00e1kat<\/strong>: Fels\u0151 oldali elektronikus (\u00e1ll\u00edthat\u00f3 id\u0151z\u00edt\u00e9ssel) + als\u00f3 oldali termikus-m\u00e1gneses (gyors)<\/li>\n<li><strong>Ellen\u0151rizze az id\u0151-\u00e1ram karakterisztik\u00e1kat<\/strong>: Biztos\u00edtson legal\u00e1bb 100-200 ms sz\u00e9tv\u00e1laszt\u00e1si id\u0151t minden hibaszinten<\/li>\n<li><strong>Fontolja meg az S-sorozatot vagy a ZSI-t<\/strong>: Egyes gy\u00e1rt\u00f3k \u201cszelekt\u00edv\u201d vagy z\u00f3naszelekt\u00edv reteszel\u00e9st k\u00edn\u00e1lnak a garant\u00e1lt koordin\u00e1ci\u00f3 \u00e9rdek\u00e9ben<\/li>\n<\/ul>\n<h3>Transzform\u00e1tor szekunder oldali v\u00e9delm\u00e9nek p\u00e9ld\u00e1ja<\/h3>\n<p>Egy 1000kVA \/ 400V-os transzform\u00e1torhoz (In \u2248 1443A szekunder):<\/p>\n<ol>\n<li><strong>Sz\u00e1m\u00edtsa ki a hiba\u00e1ramot<\/strong>: Ha a transzform\u00e1tor impedanci\u00e1ja Zk = 6%, a szekunder oldali hiba \u2248 24 x In = 34,6kA<\/li>\n<li><strong>V\u00e1lassza ki a megszak\u00edt\u00f3 \u00e9rt\u00e9k\u00e9t<\/strong>: V\u00e1lasszon 630A-es MCCB-t f\u0151megszak\u00edt\u00f3nak (lehet\u0151v\u00e9 teszi a j\u00f6v\u0151beni terhel\u00e9sn\u00f6veked\u00e9st ~440kW-ig)<\/li>\n<li><strong>Adja meg a megszak\u00edt\u00f3k\u00e9pess\u00e9get<\/strong>: Icu \u2265 35kA; v\u00e1lasszon 50kA vagy 65kA keretet a biztons\u00e1gi tartal\u00e9k \u00e9rdek\u00e9ben<\/li>\n<li><strong>Kiold\u00e1si be\u00e1ll\u00edt\u00e1sok<\/strong>: Ir = 0,8 x 630A = 504A (lehet\u0151v\u00e9 teszi az 1443A-es bet\u00e1pl\u00e1l\u00e1st t\u00falterhel\u00e9ses kiold\u00e1s n\u00e9lk\u00fcl)<\/li>\n<li><strong>Koordin\u00e1ci\u00f3<\/strong>: \u00c1ll\u00edtsa be az Isd = 3000A \u00e9rt\u00e9ket 0,2s k\u00e9sleltet\u00e9ssel a downstream 250A-es megszak\u00edt\u00f3kkal val\u00f3 szelektivit\u00e1s \u00e9rdek\u00e9ben<\/li>\n<\/ol>\n<h3>Mikor v\u00e1lasszunk k\u00f6zepes keretet<\/h3>\n<ul>\n<li><strong>Terhel\u00e9si \u00e1ram<\/strong> 250-630A<\/li>\n<li><strong>Z\u00e1rlati szint<\/strong> 30-85kA<\/li>\n<li><strong>Alkalmaz\u00e1s<\/strong> f\u0151eloszt\u00f3 t\u00e1bl\u00e1kat, \u00e9p\u00fcletbe bej\u00f6v\u0151 t\u00e1pl\u00e1l\u00e1st vagy ipari bet\u00e1pl\u00e1l\u00e1sokat foglal mag\u00e1ban<\/li>\n<li><strong>Szelektivit\u00e1s<\/strong> koordin\u00e1ci\u00f3 sz\u00fcks\u00e9ges a downstream megszak\u00edt\u00f3kkal<\/li>\n<li><strong>Kommunik\u00e1ci\u00f3<\/strong> integr\u00e1ci\u00f3 sz\u00fcks\u00e9ges a BMS\/SCADA-val<\/li>\n<\/ul>\n<h2>Nagy keret\u0171 MCCB-k (630A \u2013 1600A)<\/h2>\n<p>A nagy keret\u0171 MCCB-k v\u00e9dik a f\u0151 bej\u00f6v\u0151ket, a kapcsol\u00f3berendez\u00e9sek gy\u0171jt\u0151s\u00edn szakaszait \u00e9s a nagy ipari terhel\u00e9seket. Ezek a megszak\u00edt\u00f3k a f\u0151 v\u00e9delmi eszk\u00f6zk\u00e9nt szolg\u00e1lnak a k\u00f6zm\u0171vi bet\u00e1pl\u00e1l\u00e1s (vagy a helysz\u00edni termel\u00e9s) \u00e9s a l\u00e9tes\u00edtm\u00e9ny eloszt\u00f3rendszere k\u00f6z\u00f6tt. Ezen a szinten egyetlen megszak\u00edt\u00f3 meghib\u00e1sod\u00e1sa le\u00e1ll\u00edthat egy eg\u00e9sz \u00e9p\u00fcletet vagy gy\u00e1rt\u00f3sort \u2013 a megb\u00edzhat\u00f3s\u00e1g \u00e9s a koordin\u00e1ci\u00f3 nem alku t\u00e1rgya.<\/p>\n<h3>Szabv\u00e1nyos \u00e1ram\u00e9rt\u00e9kek<\/h3>\n<table>\n<tbody>\n<tr>\n<td><strong>\u00c9rt\u00e9k (A)<\/strong><\/td>\n<td><strong>Tipikus alkalmaz\u00e1sok<\/strong><\/td>\n<td><strong>Tipikus Icu tartom\u00e1ny<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>630A<\/strong><\/td>\n<td>Kis ipari f\u0151 bej\u00f6v\u0151, nagy \u00e9p\u00fcletbe bej\u00f6v\u0151 t\u00e1pl\u00e1l\u00e1s<\/td>\n<td>50kA \u2013 100kA<\/td>\n<\/tr>\n<tr>\n<td><strong>800A<\/strong><\/td>\n<td>K\u00f6zepes ipari f\u0151, t\u00f6bb \u00e9p\u00fcletb\u0151l \u00e1ll\u00f3 campus eloszt\u00e1sa<\/td>\n<td>65kA \u2013 100kA<\/td>\n<\/tr>\n<tr>\n<td><strong>1000A<\/strong><\/td>\n<td>Ipari f\u0151kapcsol\u00f3 t\u00e1bla, adatk\u00f6zpont UPS bej\u00f6v\u0151<\/td>\n<td>65kA \u2013 100kA<\/td>\n<\/tr>\n<tr>\n<td><strong>1250A<\/strong><\/td>\n<td>Nagy ipari f\u0151, nagy kereskedelmi komplexumok<\/td>\n<td>85kA \u2013 100kA<\/td>\n<\/tr>\n<tr>\n<td><strong>1600A<\/strong><\/td>\n<td>Maxim\u00e1lis MCCB n\u00e9vleges \u00e9rt\u00e9k; f\u0151kapcsol\u00f3 berendez\u00e9s, els\u0151dleges bej\u00f6v\u0151k<\/td>\n<td>85kA \u2013 150kA<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>M\u0171szaki jellemz\u0151k<\/h3>\n<p><strong>T\u00f6r\u00e9si kapacit\u00e1s<\/strong>: A nagy keretek k\u00edn\u00e1lj\u00e1k a legmagasabb Icu \u00e9rt\u00e9keket, amelyek az MCCB technol\u00f3gi\u00e1ban el\u00e9rhet\u0151k \u2013 65-150kA. E szint felett \u00e1ltal\u00e1ban \u00e1tt\u00e9r\u00fcnk a <a href=\"https:\/\/test.viox.com\/hu\/complete-guide-to-air-circuit-breakers-acb\/\">L\u00e9gmegszak\u00edt\u00f3k (ACB-k)<\/a> kih\u00fazhat\u00f3 kivitelre.<\/p>\n<p><strong>Fejlett elektronikus kiold\u00f3 egys\u00e9gek<\/strong>: A nagy keret\u0171 MCCB-k kifinomult, mikroprocesszor \u00e1ltal vez\u00e9relt kiold\u00f3 egys\u00e9gekkel rendelkeznek:<\/p>\n<ul>\n<li><strong>Programozhat\u00f3 id\u0151-\u00e1ram karakterisztik\u00e1k<\/strong>: ANSI g\u00f6rb\u00e9k, IEC g\u00f6rb\u00e9k vagy egyedi be\u00e1ll\u00edt\u00e1sok<\/li>\n<li><strong>F\u00f6ldz\u00e1rlat elleni v\u00e9delem<\/strong>: \u00c1ll\u00edthat\u00f3 \u00e9rz\u00e9kenys\u00e9g \u00e9s id\u0151z\u00edt\u00e9s (30mA-t\u0151l 1200A-ig)<\/li>\n<li><strong>Nullavezet\u0151 v\u00e9delem<\/strong>: 4 p\u00f3lus\u00fa egys\u00e9gek nullavezet\u0151 \u00e1ram figyel\u00e9ssel<\/li>\n<li><strong>\u00cdvhiba \u00e9rz\u00e9kel\u00e9s<\/strong>: Opcion\u00e1lis AFCI modulok a t\u0171zmegel\u0151z\u00e9shez<\/li>\n<li><strong>M\u00e9r\u00e9s \u00e9s adatr\u00f6gz\u00edt\u00e9s<\/strong>: Val\u00f3s idej\u0171 \u00e1ram, fesz\u00fclts\u00e9g, teljes\u00edtm\u00e9ny, energia, harmonikusok<\/li>\n<li><strong>Kommunik\u00e1ci\u00f3s protokollok<\/strong>: Modbus TCP\/IP, Profinet, BACnet az integr\u00e1ci\u00f3hoz<\/li>\n<\/ul>\n<p><strong>Fizikai m\u00e9retek<\/strong>: Egy 1600A-es 4 p\u00f3lus\u00fa MCCB m\u00e9rete 300mm (Sz) x 380mm (Ma) x 140mm (M\u00e9) lehet. A s\u00falya meghaladja a 15 kg-ot. A telep\u00edt\u00e9shez biztons\u00e1gos r\u00f6gz\u00edt\u00e9s sz\u00fcks\u00e9ges a n\u00e9vleges gy\u0171jt\u0151s\u00ednhez vagy k\u00e1belsarukhoz, megfelel\u0151 nyomat\u00e9kspecifik\u00e1ci\u00f3kkal (gyakran 40-60 Nm sorkapocs nyomat\u00e9k).<\/p>\n<p><strong>Tesztel\u00e9s \u00e9s karbantart\u00e1s<\/strong>: Az IEC 60947-2 el\u0151\u00edrja, hogy a nagy keret\u0171 MCCB-knek meghat\u00e1rozott tesztsorozatokat kell kib\u00edrniuk. Jelent\u0151s hib\u00e1k (Icu k\u00f6zel\u00e9ben) ut\u00e1n ellen\u0151rizze az \u00e9rintkez\u0151k er\u00f3zi\u00f3j\u00e1t, az \u00edvolt\u00f3 kamra \u00e1llapot\u00e1t \u00e9s a mechanizmus kop\u00e1s\u00e1t. Sok helysz\u00ednen \u00e9vente v\u00e9geznek kiold\u00e1si teszteket \u00e9s 3-5 \u00e9vente \u00e9rintkez\u00e9si ellen\u00e1ll\u00e1s ellen\u0151rz\u00e9seket.<\/p>\n<h3>Kapcsol\u00f3berendez\u00e9s f\u0151 bej\u00f6v\u0151 p\u00e9lda<\/h3>\n<p>Egy 2500kVA \/ 400V-os ipari l\u00e9tes\u00edtm\u00e9nyhez (becs\u00fclt terhel\u00e9s 3608A, ig\u00e9nyt\u00e9nyez\u0151 0,6 = 2165A):<\/p>\n<ol>\n<li><strong>Sz\u00e1m\u00edtsa ki a hiba\u00e1ramot<\/strong>: K\u00f6zm\u0171vi hiba hozz\u00e1j\u00e1rul\u00e1s = 80kA a csatlakoz\u00e1si ponton<\/li>\n<li><strong>V\u00e1lassza ki a megszak\u00edt\u00f3 \u00e9rt\u00e9k\u00e9t<\/strong>: V\u00e1lasszon 1600A-es MCCB-t (a k\u00f6vetkez\u0151 szabv\u00e1nyos m\u00e9ret a 2165A-es ig\u00e9ny felett, lehet\u0151v\u00e9 teszi a n\u00f6veked\u00e9st)<\/li>\n<li><strong>Adja meg a megszak\u00edt\u00f3k\u00e9pess\u00e9get<\/strong>: Icu \u2265 80kA; v\u00e1lasszon 100kA keretet a biztons\u00e1gi tartal\u00e9k \u00e9rdek\u00e9ben<\/li>\n<li><strong>Kiold\u00e1si be\u00e1ll\u00edt\u00e1sok<\/strong>: Ir = 0,9 x 1600A = 1440A, Isd = 6400A \/ 0,4s, Ii = 15000A<\/li>\n<li><strong>Koordin\u00e1ci\u00f3<\/strong>: Ellen\u0151rizze a szelektivit\u00e1st a lefel\u00e9 men\u0151 630A-es bet\u00e1pl\u00e1l\u00e1sokkal az id\u0151-\u00e1ram g\u00f6rb\u00e9k seg\u00edts\u00e9g\u00e9vel<\/li>\n<li><strong>Kommunik\u00e1ci\u00f3<\/strong>: Csatlakoz\u00e1s SCADA-hoz a terhel\u00e9s figyel\u00e9s\u00e9hez \u00e9s a t\u00e1voli lekapcsol\u00e1si k\u00e9pess\u00e9ghez<\/li>\n<\/ol>\n<h3>ACB vs. Nagykeretes MCCB<\/h3>\n<p><strong>Maradjon az MCCB-n\u00e9l, ha<\/strong>:<\/p>\n<ul>\n<li>\u00c1ram \u2264 1600A<\/li>\n<li>Z\u00e1rlati szint \u2264 100kA (vagy 150kA nagy teljes\u00edtm\u00e9ny\u0171 modellekkel)<\/li>\n<li>Fix telep\u00edt\u00e9s (nincs sz\u00fcks\u00e9g kih\u00fazhat\u00f3 szervizel\u00e9sre)<\/li>\n<li>A k\u00f6lts\u00e9gvet\u00e9si korl\u00e1tok a kompakt MCCB-t r\u00e9szes\u00edtik el\u0151nyben az ACB-vel szemben<\/li>\n<\/ul>\n<p><strong>V\u00e1ltson ACB-re, ha<\/strong>:<\/p>\n<ul>\n<li>\u00c1ram &gt; 1600A (az ACB-k 6300A-ig terjednek+)<\/li>\n<li>Kih\u00fazhat\u00f3 konstrukci\u00f3 sz\u00fcks\u00e9ges a karbantart\u00e1shoz \u00e1ll\u00e1sid\u0151 n\u00e9lk\u00fcl<\/li>\n<li>Rendk\u00edv\u00fcl magas z\u00e1rlati szintek (&gt;100kA) ACB megszak\u00edt\u00e1si technol\u00f3gi\u00e1t ig\u00e9nyelnek<\/li>\n<li>Az alkalmaz\u00e1s l\u00e1that\u00f3 kontaktus sz\u00e9tv\u00e1laszt\u00e1st vagy kiterjedt seg\u00e9d\u00e9rintkez\u0151ket ig\u00e9nyel<\/li>\n<\/ul>\n<h3>Mikor v\u00e1lasszon nagykeretest<\/h3>\n<ul>\n<li><strong>Terhel\u00e9si \u00e1ram<\/strong> 630-1600A<\/li>\n<li><strong>Z\u00e1rlati szint<\/strong> 50-150kA<\/li>\n<li><strong>Alkalmaz\u00e1s<\/strong> mag\u00e1ban foglalja a f\u0151 bet\u00e1pl\u00e1l\u00e1sokat, a kapcsol\u00f3berendez\u00e9seket vagy a kritikus eloszt\u00e1si pontokat<\/li>\n<li><strong>Speci\u00e1lis v\u00e9delem<\/strong> (m\u00e9r\u00e9s, kommunik\u00e1ci\u00f3, f\u00f6ldz\u00e1rlat) sz\u00fcks\u00e9ges<\/li>\n<li><strong>K\u00f6lts\u00e9gvet\u00e9s \u00e9s hely<\/strong> az MCCB technol\u00f3gi\u00e1t r\u00e9szes\u00edti el\u0151nyben az ACB-vel szemben<\/li>\n<\/ul>\n<h2>Hogyan olvassuk le az MCCB adatt\u00e1bl\u00e1it<\/h2>\n<p>Minden IEC-nek megfelel\u0151 MCCB adatt\u00e1bl\u00e1t (n\u00e9vt\u00e1bl\u00e1t) tartalmaz, amely kritikus specifik\u00e1ci\u00f3s adatokat jelen\u00edt meg. Az inform\u00e1ci\u00f3k dek\u00f3dol\u00e1s\u00e1nak meg\u00e9rt\u00e9se biztos\u00edtja, hogy helyesen v\u00e1lassza ki, telep\u00edtse \u00e9s tartsa karban a megszak\u00edt\u00f3kat.<\/p>\n<h3>Alapvet\u0151 adatt\u00e1bla inform\u00e1ci\u00f3k<\/h3>\n<p>Egy tipikus MCCB adatt\u00e1bla a k\u00f6vetkez\u0151ket tartalmazza:<\/p>\n<ul>\n<li><strong>1. Gy\u00e1rt\u00f3 \u00e9s modell<\/strong>: M\u00e1rkan\u00e9v \u00e9s term\u00e9ksorozat (pl. \u201cVIOX VMC3-630\u201d)<\/li>\n<li><strong>2. IEC szabv\u00e1ny jel\u00f6l\u00e9s<\/strong>: Az \u201cIEC 60947-2\u201d vagy \u201cEN 60947-2\u201d meger\u0151s\u00edti a megfelel\u0151s\u00e9get<\/li>\n<li><strong>3. N\u00e9vleges \u00e1ram (In)<\/strong>: A megszak\u00edt\u00f3 n\u00e9vleges \u00e1ramer\u0151ss\u00e9ge referencia k\u00f6rnyezeti h\u0151m\u00e9rs\u00e9kleten (40\u00b0C)<\/li>\n<li><strong>4. N\u00e9vleges fesz\u00fclts\u00e9g (Ue)<\/strong>: \u00dczemi fesz\u00fclts\u00e9g (pl. 690V AC, 250V DC)<\/li>\n<li><strong>5. Megszak\u00edt\u00f3k\u00e9pess\u00e9g (Icu \/ Ics)<\/strong>: Icu (v\u00e9gs\u0151) \u00e9s Ics (\u00fczemi) hat\u00e1r\u00e9rt\u00e9kek kA-ben<\/li>\n<li><strong>6. Felhaszn\u00e1l\u00e1si kateg\u00f3ria<\/strong>: A kateg\u00f3ria (azonnali) vagy B kateg\u00f3ria (id\u0151k\u00e9sleltetett)<\/li>\n<li><strong>7. N\u00e9vleges szigetel\u00e9si fesz\u00fclts\u00e9g (Ui)<\/strong>: Maxim\u00e1lis rendszerfesz\u00fclts\u00e9g t\u0171r\u00e9s<\/li>\n<li><strong>8. N\u00e9vleges l\u00f6k\u0151fesz\u00fclts\u00e9g \u00e1ll\u00f3s\u00e1g (Uimp)<\/strong>: T\u00falfesz\u00fclts\u00e9g immunit\u00e1s (pl. 8kV)<\/li>\n<li><strong>9. P\u00f3lusok \u00e9s konfigur\u00e1ci\u00f3<\/strong>: 3P vagy 4P<\/li>\n<li><strong>10. Kiold\u00e1si be\u00e1ll\u00edt\u00e1sok<\/strong>: Ir, Isd, Ii tartom\u00e1nyok (ha \u00e1ll\u00edthat\u00f3)<\/li>\n<li><strong>11. Tan\u00fas\u00edtv\u00e1nyok<\/strong>: CE, CCC, UL jelek<\/li>\n<\/ul>\n<figure><img decoding=\"async\" src=\"https:\/\/img.viox.com\/mccb-rating-plate-example-showing-all-specifications.webp\" alt=\"MCCB Rating Plate Example showing all specifications\" \/><figcaption>3. \u00e1bra: R\u00e9szletes MCCB adatt\u00e1bla, amely alapvet\u0151 specifik\u00e1ci\u00f3kat jelen\u00edt meg: In (n\u00e9vleges \u00e1ram), Ue (\u00fczemi fesz\u00fclts\u00e9g), Icu\/Ics (megszak\u00edt\u00f3k\u00e9pess\u00e9g), IEC 60947-2 megfelel\u0151s\u00e9g, kiold\u00e1si be\u00e1ll\u00edt\u00e1sok \u00e9s tan\u00fas\u00edt\u00e1si jelek. Telep\u00edt\u00e9s el\u0151tt mindig ellen\u0151rizze, hogy ezek a param\u00e9terek megfelelnek-e a tervez\u00e9si k\u00f6vetelm\u00e9nyeknek.<\/figcaption><\/figure>\n<h3>Mit kell ellen\u0151rizni a telep\u00edt\u00e9s el\u0151tt<\/h3>\n<ol>\n<li><strong>In \u2265 sz\u00e1m\u00edtott terhel\u00e9si \u00e1ram<\/strong> (adott esetben h\u0151m\u00e9rs\u00e9klet\/csoportos\u00edt\u00e1s miatti cs\u00f6kkent\u00e9ssel)<\/li>\n<li><strong>Ue = rendszerfesz\u00fclts\u00e9g<\/strong> (egyeznie kell; a 400V-os megszak\u00edt\u00f3 nem v\u00e9dheti a 690V-os rendszert)<\/li>\n<li><strong>Icu \u2265 v\u00e1rhat\u00f3 z\u00e1rlati \u00e1ram<\/strong> a telep\u00edt\u00e9si ponton<\/li>\n<li><strong>Ics megfelel\u0151<\/strong> az alkalmaz\u00e1shoz (a legkritikusabb alkalmaz\u00e1sokhoz 75-100%)<\/li>\n<li><strong>A p\u00f3lusok illeszkednek a rendszerhez<\/strong>: 3P h\u00e1romf\u00e1zis\u00fahoz, 4P, ha semleges v\u00e9delem sz\u00fcks\u00e9ges<\/li>\n<li><strong>Kiold\u00e1si be\u00e1ll\u00edt\u00e1sok<\/strong> (ha \u00e1ll\u00edthat\u00f3) a koordin\u00e1ci\u00f3s tanulm\u00e1ny szerint konfigur\u00e1lva<\/li>\n<li><strong>Tan\u00fas\u00edtv\u00e1nyok<\/strong> \u00e9rv\u00e9nyes a telep\u00edt\u00e9si r\u00e9gi\u00f3ra<\/li>\n<\/ol>\n<h2>Kiv\u00e1laszt\u00e1si \u00fatmutat\u00f3 alkalmaz\u00e1s szerint<\/h2>\n<p>A megfelel\u0151 MCCB \u00e1ramer\u0151ss\u00e9g kiv\u00e1laszt\u00e1sa az adott alkalmaz\u00e1st\u00f3l, a terhel\u00e9s t\u00edpus\u00e1t\u00f3l, a z\u00e1rlati szintt\u0151l \u00e9s a koordin\u00e1ci\u00f3s k\u00f6vetelm\u00e9nyekt\u0151l f\u00fcgg.<\/p>\n<h3>Gyors kiv\u00e1laszt\u00e1si t\u00e1bl\u00e1zat<\/h3>\n<table>\n<tbody>\n<tr>\n<td><strong>Alkalmaz\u00e1s<\/strong><\/td>\n<td><strong>Terhel\u00e9si \u00e1ram<\/strong><\/td>\n<td><strong>Aj\u00e1nlott MCCB n\u00e9vleges \u00e9rt\u00e9k<\/strong><\/td>\n<td><strong>Tipikus Icu<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Kismotor (7,5kW)<\/td>\n<td>15A<\/td>\n<td><strong>20A vagy 25A<\/strong><\/td>\n<td>25-36kA<\/td>\n<\/tr>\n<tr>\n<td>K\u00f6zepes motor (30kW)<\/td>\n<td>57A<\/td>\n<td><strong>63A vagy 80A<\/strong><\/td>\n<td>36-50kA<\/td>\n<\/tr>\n<tr>\n<td>Nagy motor (110kW)<\/td>\n<td>200A<\/td>\n<td><strong>250A<\/strong><\/td>\n<td>50-65kA<\/td>\n<\/tr>\n<tr>\n<td>Irodai szint bet\u00e1pl\u00e1l\u00e1sa<\/td>\n<td>180A<\/td>\n<td><strong>200A vagy 250A<\/strong><\/td>\n<td>36-50kA<\/td>\n<\/tr>\n<tr>\n<td>\u00c9p\u00fclet f\u0151eloszt\u00f3ja<\/td>\n<td>450A<\/td>\n<td><strong>500A vagy 630A<\/strong><\/td>\n<td>50-65kA<\/td>\n<\/tr>\n<tr>\n<td>Kism\u00e9ret\u0171 szerviz bej\u00e1rat<\/td>\n<td>650A<\/td>\n<td><strong>800A<\/strong><\/td>\n<td>65-85kA<\/td>\n<\/tr>\n<tr>\n<td>Ipari f\u0151eloszt\u00f3<\/td>\n<td>1200A<\/td>\n<td><strong>1250A vagy 1600A<\/strong><\/td>\n<td>85-100kA<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Kritikus kiv\u00e1laszt\u00e1si eml\u00e9keztet\u0151k<\/h3>\n<ol>\n<li><strong>Soha ne m\u00e9retezze alul az In-t<\/strong>: Egy megszak\u00edt\u00f3, amely n\u00e9vleges \u00e9rt\u00e9k\u00e9nek 90%-\u00e1t folyamatosan viszi, t\u00falmelegszik \u00e9s leromlik<\/li>\n<li><strong>Mindig ellen\u0151rizze az Icu-t<\/strong>: Az alulm\u00e9retezett megszak\u00edt\u00f3k\u00e9pess\u00e9g katasztrof\u00e1lis megszak\u00edt\u00f3hib\u00e1t okozhat z\u00e1rlatok eset\u00e9n<\/li>\n<li><strong>Ellen\u0151rizze a k\u00f6rnyezeti h\u0151m\u00e9rs\u00e9kletet<\/strong>: A szabv\u00e1nyos n\u00e9vleges \u00e9rt\u00e9kek 40\u00b0C-ot felt\u00e9teleznek; magasabb h\u0151m\u00e9rs\u00e9klet eset\u00e9n cs\u00f6kkentse a n\u00e9vleges \u00e9rt\u00e9ket (0,9x 50\u00b0C-on, 0,8x 60\u00b0C-on)<\/li>\n<li><strong>Hangolja \u00f6ssze az id\u0151-\u00e1ram g\u00f6rb\u00e9ket<\/strong>: Haszn\u00e1ljon gy\u00e1rt\u00f3i szoftvert a szelektivit\u00e1s ellen\u0151rz\u00e9s\u00e9hez a teljes eloszt\u00f3rendszerben<\/li>\n<li><strong>Vegye figyelembe a j\u00f6v\u0151beli n\u00f6veked\u00e9st<\/strong>: Adjon meg 10-25%-os tartal\u00e9kot az In-ben a l\u00e9tes\u00edtm\u00e9ny b\u0151v\u00edt\u00e9s\u00e9hez<\/li>\n<\/ol>\n<figure><img decoding=\"async\" src=\"https:\/\/img.viox.com\/mccb-selection-decision-flowchart.webp\" alt=\"MCCB Selection Decision Flowchart\" \/><figcaption>5. \u00e1bra: MCCB kiv\u00e1laszt\u00e1si folyamat\u00e1bra, amely a terhel\u00e9si \u00e1ram alapj\u00e1n ir\u00e1ny\u00edtja a keretm\u00e9ret meghat\u00e1roz\u00e1s\u00e1t, majd a megszak\u00edt\u00f3k\u00e9pess\u00e9g ellen\u0151rz\u00e9s\u00e9t, a szerviz n\u00e9vleges \u00e9rt\u00e9k\u00e9nek ellen\u0151rz\u00e9s\u00e9t \u00e9s a koordin\u00e1ci\u00f3s elemz\u00e9st. Haszn\u00e1lja ezt a szisztematikus megk\u00f6zel\u00edt\u00e9st az alkalmaz\u00e1s\u00e1hoz megfelel\u0151 megszak\u00edt\u00f3 specifik\u00e1ci\u00f3 biztos\u00edt\u00e1s\u00e1hoz.<\/figcaption><\/figure>\n<h2>K\u00f6vetkeztet\u00e9s<\/h2>\n<p>A 16A-t\u00f3l 1600A-ig terjed\u0151 szabv\u00e1nyos MCCB \u00e1ram\u00e9rt\u00e9kek k\u00e9pezik a modern elektromos eloszt\u00f3rendszerek alapj\u00e1t. A keretm\u00e9retek, az \u00e1ram\u00e9rt\u00e9kek \u00e9s a megszak\u00edt\u00f3k\u00e9pess\u00e9gek k\u00f6z\u00f6tti kapcsolat meg\u00e9rt\u00e9se lehet\u0151v\u00e9 teszi, hogy olyan megszak\u00edt\u00f3kat specifik\u00e1ljon, amelyek v\u00e9dik a berendez\u00e9seket, biztos\u00edtj\u00e1k a rendszer koordin\u00e1ci\u00f3j\u00e1t \u00e9s megfelelnek az IEC 60947-2 biztons\u00e1gi szabv\u00e1nyoknak.<\/p>\n<p>F\u0151bb tudnival\u00f3k:<\/p>\n<ul>\n<li><strong>Az In-t igaz\u00edtsa a terhel\u00e9si k\u00f6vetelm\u00e9nyekhez<\/strong> 10-25%-os tartal\u00e9kkal a n\u00f6veked\u00e9shez \u00e9s a n\u00e9vleges \u00e9rt\u00e9k cs\u00f6kkent\u00e9s\u00e9hez<\/li>\n<li><strong>Ellen\u0151rizze az Icu-t a z\u00e1rlati tanulm\u00e1nyok alapj\u00e1n<\/strong>\u2013 soha ne szereljen be el\u00e9gtelen megszak\u00edt\u00f3k\u00e9pess\u00e9g\u0171 megszak\u00edt\u00f3t<\/li>\n<li><strong>V\u00e1lassza ki b\u00f6lcsen a keretm\u00e9retet<\/strong>\u2013 kis keretek \u226450kA \/ \u2264250A-hez, k\u00f6zepesek 30-85kA \/ 250-630A-hez, nagyok 50-150kA \/ 630-1600A-hez<\/li>\n<li><strong>Olvassa el figyelmesen a adatt\u00e1bl\u00e1kat<\/strong>\u2013 a telep\u00edt\u00e9s el\u0151tt ellen\u0151rizze az In, Ue, Icu, Ics, p\u00f3lusok \u00e9s tan\u00fas\u00edtv\u00e1nyok adatait<\/li>\n<li><strong>Hangolja \u00f6ssze a rendszer tanulm\u00e1nyokkal<\/strong>\u2013 haszn\u00e1ljon id\u0151-\u00e1ram g\u00f6rb\u00e9ket a szelektivit\u00e1s biztos\u00edt\u00e1s\u00e1hoz az eloszt\u00e1si hierarchi\u00e1ban<\/li>\n<\/ul>\n<p>Ak\u00e1r egy 30 kW-os motort v\u00e9d 63A-es megszak\u00edt\u00f3val, ak\u00e1r egy 1600A-es f\u0151 bet\u00e1pl\u00e1l\u00e1st specifik\u00e1l egy ipari l\u00e9tes\u00edtm\u00e9nyhez, az elvek ugyanazok maradnak: pontos terhel\u00e9ssz\u00e1m\u00edt\u00e1s, megfelel\u0151 megszak\u00edt\u00f3k\u00e9pess\u00e9g \u00e9s ellen\u0151rz\u00f6tt koordin\u00e1ci\u00f3.<\/p>\n<hr \/>\n<p><strong>Seg\u00edts\u00e9gre van sz\u00fcks\u00e9ge a megfelel\u0151 MCCB kiv\u00e1laszt\u00e1s\u00e1hoz a projektj\u00e9hez?<\/strong> A VIOX Electric IEC 60947-2 szabv\u00e1nynak megfelel\u0151 MCCB-ket gy\u00e1rt minden szabv\u00e1nyos n\u00e9vleges \u00e9rt\u00e9kben 16A-t\u00f3l 1600A-ig. M\u00e9rn\u00f6ki csapatunk technikai t\u00e1mogat\u00e1st ny\u00fajt a megszak\u00edt\u00f3 kiv\u00e1laszt\u00e1s\u00e1hoz, a koordin\u00e1ci\u00f3s tanulm\u00e1nyokhoz \u00e9s a rendszertervez\u00e9shez. <a href=\"#\">Vegye fel vel\u00fcnk a kapcsolatot a specifik\u00e1ci\u00f3k\u00e9rt \u00e9s a m\u0171szaki tan\u00e1csad\u00e1s\u00e9rt.<\/a><\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Selecting the right molded case circuit breaker (MCCB) starts with understanding standard breaker sizes. Unlike miniature circuit breakers (MCBs) that protect final circuits, MCCBs cover a much wider current range\u2014from 16A branch feeders to 1600A main incomers\u2014and choosing the correct rating directly impacts system safety, coordination, and project costs. This guide maps the complete IEC [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":20574,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1],"tags":[],"class_list":["post-20573","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"_links":{"self":[{"href":"https:\/\/test.viox.com\/hu\/wp-json\/wp\/v2\/posts\/20573","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/test.viox.com\/hu\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/test.viox.com\/hu\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/test.viox.com\/hu\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/test.viox.com\/hu\/wp-json\/wp\/v2\/comments?post=20573"}],"version-history":[{"count":4,"href":"https:\/\/test.viox.com\/hu\/wp-json\/wp\/v2\/posts\/20573\/revisions"}],"predecessor-version":[{"id":20578,"href":"https:\/\/test.viox.com\/hu\/wp-json\/wp\/v2\/posts\/20573\/revisions\/20578"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/test.viox.com\/hu\/wp-json\/wp\/v2\/media\/20574"}],"wp:attachment":[{"href":"https:\/\/test.viox.com\/hu\/wp-json\/wp\/v2\/media?parent=20573"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/test.viox.com\/hu\/wp-json\/wp\/v2\/categories?post=20573"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/test.viox.com\/hu\/wp-json\/wp\/v2\/tags?post=20573"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}