{"id":17389,"date":"2025-06-01T23:19:34","date_gmt":"2025-06-01T15:19:34","guid":{"rendered":"https:\/\/viox.com\/?p=17389"},"modified":"2025-06-01T23:19:48","modified_gmt":"2025-06-01T15:19:48","slug":"british-standard-switch-socket-installation-guide","status":"publish","type":"post","link":"https:\/\/test.viox.com\/hu\/british-standard-switch-socket-installation-guide\/","title":{"rendered":"Brit szabv\u00e1ny\u00fa kapcsol\u00f3aljzat-telep\u00edt\u00e9si \u00fatmutat\u00f3 | BS 1363 bark\u00e1csbiztons\u00e1g \u00e9s vezet\u00e9kez\u00e9s"},"content":{"rendered":"<div class=\"product-intro\">\n<p>Egy brit szabv\u00e1ny\u00fa kapcsol\u00f3aljzat telep\u00edt\u00e9s\u00e9hez ismerni kell az Egyes\u00fclt Kir\u00e1lys\u00e1g elektromos el\u0151\u00edr\u00e1sait, biztons\u00e1gi protokolljait \u00e9s a megfelel\u0151 bek\u00f6t\u00e9si technik\u00e1kat. Ez az \u00e1tfog\u00f3 \u00fatmutat\u00f3 mindent lefed a t\u00f6rt\u00e9nelmi kontextust\u00f3l a halad\u00f3 telep\u00edt\u00e9si elj\u00e1r\u00e1sokig, biztos\u00edtva a biztons\u00e1gos \u00e9s a BS 1363 szabv\u00e1nyoknak megfelel\u0151 aljzattelep\u00edt\u00e9st.<\/p>\n<h2>Mik azok a brit szabv\u00e1nyos kapcsol\u00f3aljzatok?<\/h2>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-17357\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/06\/UK-Switch-and-Socket-manufacturer.webp\" alt=\"UK Switch and Socket manufacturer\" width=\"800\" height=\"668\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/06\/UK-Switch-and-Socket-manufacturer.webp 800w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/06\/UK-Switch-and-Socket-manufacturer-300x251.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/06\/UK-Switch-and-Socket-manufacturer-768x641.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/06\/UK-Switch-and-Socket-manufacturer-14x12.webp 14w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/06\/UK-Switch-and-Socket-manufacturer-600x501.webp 600w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<p style=\"text-align: center;\"><a href=\"https:\/\/test.viox.com\/hu\/uk-switch-and-socket\/\">VIOX brit szabv\u00e1ny\u00fa aljzatok<\/a><\/p>\n<p>A brit szabv\u00e1ny\u00fa konnektorok (BS 1363) a vil\u00e1g egyik legbiztons\u00e1gosabb elektromos aljzat-kialak\u00edt\u00e1s\u00e1t k\u00e9pviselik, 13 A-es, 250 V-os v\u00e1ltakoz\u00f3 \u00e1ram\u00fa aljzatokkal, amelyek h\u00e1rom n\u00e9gyzet alak\u00fa, h\u00e1romsz\u00f6g alak\u00fa \u00e9rintkez\u0151vel rendelkeznek. Ezek a konnektorok a m\u00e1sodik vil\u00e1gh\u00e1bor\u00fa ut\u00e1ni \u00fajj\u00e1\u00e9p\u00edt\u00e9si er\u0151fesz\u00edt\u00e9sekb\u0151l sz\u00e1rmaznak, amikor az 1944-es Villamosszerel\u00e9si Bizotts\u00e1g kritikus biztons\u00e1gi korl\u00e1tokat azonos\u00edtott a megl\u00e9v\u0151 BS 546 rendszerben, k\u00fcl\u00f6n\u00f6sen az 5 A \u00e9s 15 A k\u00f6z\u00f6tti k\u00f6zbens\u0151 \u00e1ramer\u0151ss\u00e9g hi\u00e1ny\u00e1t.<\/p>\n<h3>A BS 1363 aljzatok f\u0151bb jellemz\u0151i:<\/h3>\n<ul>\n<li><strong>Biztons\u00e1gi red\u0151ny\u00f6k<\/strong> az idegen t\u00e1rgyak bejut\u00e1s\u00e1t megakad\u00e1lyoz\u00f3 \u00e9l\u0151 \u00e9s semleges furatokon<\/li>\n<li><strong>Biztos\u00edtott dug\u00f3k<\/strong> 13 A-es biztos\u00edt\u00e9kbet\u00e9teket (BS 1362) tartalmaz t\u00fal\u00e1ramv\u00e9delemhez<\/li>\n<li><strong>F\u00f6ldel\u0151csap<\/strong> a cs\u00facson elhelyezve a fokozott elektromos biztons\u00e1g \u00e9rdek\u00e9ben<\/li>\n<li><strong>13A \u00e1ramer\u0151ss\u00e9g<\/strong> 250 V AC fesz\u00fclts\u00e9gen, gy\u0171r\u0171s \u00e1ramk\u00f6r kompatibilit\u00e1ssal<\/li>\n<li><strong>N\u00e9gyzet alak\u00fa t\u0171s konfigur\u00e1ci\u00f3<\/strong> biztos\u00edtva a helyes polariz\u00e1ci\u00f3t \u00e9s megakad\u00e1lyozva a helytelen behelyez\u00e9st<\/li>\n<\/ul>\n<p>A szabv\u00e1nyos m\u00e9retek jellemz\u0151en 86 mm x 86 mm az el\u0151lap eset\u00e9ben, \u00edgy kompatibilisek a modern brit elektromos berendez\u00e9sekkel \u00e9s eloszt\u00f3dobozokkal.<\/p>\n<h2>Jogi k\u00f6vetelm\u00e9nyek \u00e9s biztons\u00e1gi el\u0151\u00edr\u00e1sok<\/h2>\n<h3>P. r\u00e9sz \u00c9p\u00edt\u00e9si Szab\u00e1lyzatnak val\u00f3 megfelel\u00e9s<\/h3>\n<p><strong>FONTOS BIZTONS\u00c1GI FIGYELMEZTET\u00c9S:<\/strong> Az elektromos \u00e1rammal v\u00e9gzett munka vesz\u00e9lyes \u00e9s ak\u00e1r hal\u00e1los is lehet. Ha bizonytalan a munka b\u00e1rmely aspektus\u00e1ban, mindig b\u00edzzon meg szakk\u00e9pzett villanyszerel\u0151t.<\/p>\n<p>Az Egyes\u00fclt Kir\u00e1lys\u00e1gban az elektromos munk\u00e1kat az \u00c9p\u00edt\u00e9si Szab\u00e1lyzat (Anglia \u00e9s Wales) P. r\u00e9sze \u00e9s a BS 7671 brit szabv\u00e1ny szab\u00e1lyozza. Ezen k\u00f6vetelm\u00e9nyek meg\u00e9rt\u00e9se elengedhetetlen a jogszab\u00e1lyoknak val\u00f3 megfelel\u00e9shez:<\/p>\n<p><strong>Amit jogilag megtehetsz (azonos cser\u00e9k):<\/strong><\/p>\n<ul>\n<li>Megl\u00e9v\u0151 aljzatok cser\u00e9je egyen\u00e9rt\u00e9k\u0171 specifik\u00e1ci\u00f3j\u00faakra<\/li>\n<li>Egyszeres aljzatok USB-funkci\u00f3val ell\u00e1tott egyszeres aljzatokra v\u00e1lt\u00e1sa<\/li>\n<li>Dupla aljzatok cser\u00e9je dupla aljzatokra<\/li>\n<li>Kisebb jav\u00edt\u00e1sok a megl\u00e9v\u0151 aljzatok \u00e1ramk\u00f6reiben<\/li>\n<\/ul>\n<p><strong>Amihez szakk\u00e9pzett villanyszerel\u0151re van sz\u00fcks\u00e9g:<\/strong><\/p>\n<ul>\n<li>Teljesen \u00faj aljzati \u00e1ramk\u00f6r\u00f6k telep\u00edt\u00e9se vagy a megl\u00e9v\u0151 \u00e1ramk\u00f6r\u00f6k jelent\u0151s b\u0151v\u00edt\u00e9se<\/li>\n<li>Szoftveraljzatok hozz\u00e1ad\u00e1sa ott, ahol kor\u00e1bban nem l\u00e9teztek<\/li>\n<li>K\u00fclt\u00e9ri aljzatok telep\u00edt\u00e9se (30 mA-es RCD-v\u00e9delemmel)<\/li>\n<li>F\u00fcrd\u0151szobai \u00e9s k\u00fcl\u00f6nleges helysz\u00edni telep\u00edt\u00e9sek<\/li>\n<li>Munkav\u00e9gz\u00e9s kereskedelmi vagy b\u00e9rbead\u00e1si ingatlanokban<\/li>\n<\/ul>\n<h3>Brit szabv\u00e1nyos aljzatmagass\u00e1g- \u00e9s elhelyez\u00e9si el\u0151\u00edr\u00e1sok<\/h3>\n<p>A konnektorok elhelyez\u00e9s\u00e9nek meg kell felelnie az M. j\u00f3v\u00e1hagyott dokumentum akad\u00e1lymentes\u00edt\u00e9si k\u00f6vetelm\u00e9nyeinek:<\/p>\n<ul>\n<li><strong>Minim\u00e1lis magass\u00e1g:<\/strong> 450 mm-re a k\u00e9sz padl\u00f3szintt\u0151l<\/li>\n<li><strong>Maxim\u00e1lis magass\u00e1g:<\/strong> 1200 mm-re a k\u00e9sz padl\u00f3szintt\u0151l<\/li>\n<li><strong>Standard be\u00e9p\u00edt\u00e9si magass\u00e1g:<\/strong> 300-400 mm a padl\u00f3t\u00f3l a hozz\u00e1f\u00e9rhet\u0151s\u00e9g \u00e9rdek\u00e9ben<\/li>\n<li><strong>Konyhai munkalap t\u00e1vols\u00e1ga:<\/strong> Minimum 100 mm a csatlakoz\u00f3aljzatok alatt a k\u00e1belhajl\u00edt\u00e1s elker\u00fcl\u00e9se \u00e9rdek\u00e9ben<\/li>\n<li><strong>Sarokpozicion\u00e1l\u00e1s:<\/strong> Minimum 350 mm a sarkokt\u00f3l kerekessz\u00e9kkel megk\u00f6zel\u00edthet\u0151v\u00e9 t\u00e9ve<\/li>\n<li><strong>V\u00edzszintes szabad magass\u00e1g:<\/strong> Minimum 300 mm t\u00e1vols\u00e1gra a mosogat\u00f3kt\u00f3l vagy a mosd\u00f3kagyl\u00f3kt\u00f3l<\/li>\n<\/ul>\n<h2>Alapvet\u0151 eszk\u00f6z\u00f6k \u00e9s anyagok<\/h2>\n<h3>Biztons\u00e1gi \u00e9s vizsg\u00e1l\u00f3berendez\u00e9sek:<\/h3>\n<ul>\n<li><strong>Fesz\u00fclts\u00e9gm\u00e9r\u0151\/digit\u00e1lis multim\u00e9ter<\/strong> a \u201ebizony\u00edtsd halottnak, igazold az egys\u00e9get, igazold a halottnak\u201d tesztel\u00e9si protokollhoz<\/li>\n<li><strong>Dugaszol\u00f3aljzat-teszter<\/strong> a k\u00e1belez\u00e9s helyess\u00e9g\u00e9nek v\u00e9gs\u0151 ellen\u0151rz\u00e9s\u00e9hez<\/li>\n<li><strong>Szigetelt csavarh\u00faz\u00f3k<\/strong> (VDE tan\u00fas\u00edtv\u00e1nnyal) \u2013 laposfej\u0171 \u00e9s Phillips<\/li>\n<li><strong>Vezet\u00e9kcsupasz\u00edt\u00f3k\/v\u00e1g\u00f3k<\/strong> k\u00e1bel el\u0151k\u00e9sz\u00edt\u00e9s\u00e9hez<\/li>\n<li><strong>V\u00edzm\u00e9rt\u00e9k<\/strong> a pontos pozicion\u00e1l\u00e1shoz<\/li>\n<li><strong>V\u00e9d\u0151szem\u00fcveg \u00e9s porv\u00e9d\u0151 maszk<\/strong><\/li>\n<\/ul>\n<h3>Telep\u00edt\u00e9si anyagok:<\/h3>\n<ul>\n<li><strong>BS 1363 szabv\u00e1nynak megfelel\u0151 aljzat<\/strong> (egyes vagy k\u00e9tsz\u00e1rny\u00fa)<\/li>\n<li><strong>Megfelel\u0151 pattress doboz<\/strong> (f\u00e9m t\u00f6m\u00f6r falakhoz, m\u0171anyag g\u00f6dr\u00f6s falakhoz)<\/li>\n<li><strong>Csatlakoz\u00f3csavarok<\/strong> \u00e9s r\u00f6gz\u00edt\u0151elemek<\/li>\n<li><strong>Z\u00f6ld\/s\u00e1rga f\u00f6ldel\u0151h\u00fcvely<\/strong> ha sz\u00fcks\u00e9ges<\/li>\n<li><strong>Figyelmeztet\u0151 jelek<\/strong> fogyaszt\u00f3i egys\u00e9ghez munka k\u00f6zben<\/li>\n<\/ul>\n<h2>Telep\u00edt\u00e9s el\u0151tti biztons\u00e1gi protokollok<\/h2>\n<h3>\u00c1ramk\u00f6r-lev\u00e1laszt\u00e1si elj\u00e1r\u00e1s<\/h3>\n<p><strong>1. l\u00e9p\u00e9s: A megfelel\u0151 \u00e1ramk\u00f6r azonos\u00edt\u00e1sa<\/strong><\/p>\n<p>Keresse meg a fogyaszt\u00f3i egys\u00e9get, \u00e9s azonos\u00edtsa be, hogy melyik kismegszak\u00edt\u00f3 (MCB) vagy biztos\u00edt\u00e9k v\u00e9di a foglalat \u00e1ramk\u00f6r\u00e9t, amelyen dolgozik. A gy\u0171r\u0171s \u00e1ramk\u00f6r\u00f6k \u00e1ltal\u00e1ban 32 A-es MCB-ket haszn\u00e1lnak, m\u00edg a sug\u00e1rir\u00e1ny\u00fa \u00e1ramk\u00f6r\u00f6k 20 A-es MCB-ket.<\/p>\n<p><strong>2. l\u00e9p\u00e9s: Izol\u00e1lja az \u00e1ramk\u00f6rt<\/strong><\/p>\n<ul>\n<li>Kapcsolja ki a megfelel\u0151 kismegszak\u00edt\u00f3t, vagy vegye ki a biztos\u00edt\u00e9kot<\/li>\n<li>Helyezzen el egy j\u00f3l l\u00e1that\u00f3 figyelmeztet\u0151 t\u00e1bl\u00e1t: \u201eVESZ\u00c9LY \u2013 Villanyszerel\u00e9si munk\u00e1latok folyamatban \u2013 TILOS bekapcsolni\u201d<\/li>\n<li>Kapcsolja ki az \u00e1ramk\u00f6r-megszak\u00edt\u00f3t, ha lehets\u00e9ges<\/li>\n<\/ul>\n<p><strong>3. l\u00e9p\u00e9s: A halott tesztel\u00e9s bizony\u00edt\u00e1sa<\/strong><\/p>\n<p>Haszn\u00e1ld a \u201ebizony\u00edtsd be a halott, bizony\u00edtsd be az egys\u00e9get, bizony\u00edtsd be a halott\u201d m\u00f3dszertant:<\/p>\n<ol>\n<li>Teszteld a fesz\u00fclts\u00e9gm\u00e9r\u0151det egy ismert, \u00e9l\u0151 forr\u00e1son, hogy megbizonyosodj r\u00f3la, m\u0171k\u00f6dik-e.<\/li>\n<li>Ellen\u0151rizze az aljzat \u00e1ramk\u00f6r\u00e9t nulla fesz\u00fclts\u00e9gre az \u00f6sszes kombin\u00e1ci\u00f3 (f\u00e1zis-nulla, f\u00e1zis-f\u00f6ld, nulla-f\u00f6ld) k\u00f6z\u00f6tt.<\/li>\n<li>Teszteld \u00fajra a fesz\u00fclts\u00e9gm\u00e9r\u0151det az ismert \u00e9l\u0151 forr\u00e1son, hogy megbizonyosodj arr\u00f3l, hogy tov\u00e1bbra is m\u0171k\u00f6dik.<\/li>\n<\/ol>\n<h2>Az Egyes\u00fclt Kir\u00e1lys\u00e1g aljzatainak sz\u00edneinek meg\u00e9rt\u00e9se<\/h2>\n<h3>Modern vezet\u00e9kez\u00e9si sz\u00ednek (2004 ut\u00e1ni harmoniz\u00e1lt szabv\u00e1nyok):<\/h3>\n<ul>\n<li><strong>BARNA:<\/strong> F\u00e1zis (L) \u2013 a jobb oldali csatlakoz\u00f3hoz csatlakozik, ha az aljzat fel\u00e9 n\u00e9z<\/li>\n<li><strong>K\u00c9K:<\/strong> Nulla (N) \u2013 a bal oldali csatlakoz\u00f3hoz csatlakozik<\/li>\n<li><strong>Z\u00d6LD\/S\u00c1RGA CS\u00cdKOK:<\/strong> F\u00f6ldel\u00e9s (E) \u2013 a f\u00f6ldel\u0151 csatlakoz\u00f3hoz csatlakozik (fel\u00fcl)<\/li>\n<\/ul>\n<h3>R\u00e9gebbi telep\u00edt\u00e9sek (2004 el\u0151tt):<\/h3>\n<ul>\n<li><strong>PIROS:<\/strong> \u00c9l\u0151 (B)<\/li>\n<li><strong>FEKETE:<\/strong> Semleges (N)<\/li>\n<li><strong>Z\u00d6LD\/S\u00c1RGA CS\u00cdKOK vagy csupasz r\u00e9z h\u00fcvellyel:<\/strong> F\u00f6ld (K)<\/li>\n<\/ul>\n<p><strong>Fontos:<\/strong> Ha nagyon r\u00e9gi, megfelel\u0151 f\u00f6ldel\u0151vezet\u00e9k n\u00e9lk\u00fcli vezet\u00e9kekkel tal\u00e1lkozik, a folytat\u00e1s el\u0151tt konzult\u00e1ljon szakk\u00e9pzett villanyszerel\u0151vel.<\/p>\n<h2>L\u00e9p\u00e9sr\u0151l l\u00e9p\u00e9sre t\u00f6rt\u00e9n\u0151 telep\u00edt\u00e9si elj\u00e1r\u00e1s<\/h2>\n<h3>1. f\u00e1zis: Megl\u00e9v\u0151 aljzat elt\u00e1vol\u00edt\u00e1sa \u00e9s felm\u00e9r\u00e9se<\/h3>\n<p><strong>1. Dokument\u00e1lja a megl\u00e9v\u0151 vezet\u00e9keket<\/strong><\/p>\n<p>K\u00e9sz\u00edtsen tiszta f\u00e9nyk\u00e9peket a megl\u00e9v\u0151 vezet\u00e9kcsatlakoz\u00e1sokr\u00f3l, miel\u0151tt b\u00e1rmit is lev\u00e1lasztana. Ez kulcsfontoss\u00e1g\u00fa referenciaanyagk\u00e9nt szolg\u00e1l az \u00f6sszeszerel\u00e9shez.<\/p>\n<p><strong>2. El\u0151lap elt\u00e1vol\u00edt\u00e1sa<\/strong><\/p>\n<ul>\n<li>Csavarja ki a r\u00f6gz\u00edt\u0151csavarokat (\u00e1ltal\u00e1ban 3,5 mm)<\/li>\n<li>\u00d3vatosan h\u00fazza ki a foglalatot a patrontart\u00f3 dobozb\u00f3l<\/li>\n<li>Figyelje meg a megl\u00e9v\u0151 vezet\u00e9kek \u00e1llapot\u00e1t s\u00e9r\u00fcl\u00e9s, t\u00falmeleged\u00e9s vagy megfelel\u0151 hossz\u00fas\u00e1g szempontj\u00e1b\u00f3l<\/li>\n<\/ul>\n<p><strong>3. Karmester \u00e9rt\u00e9kel\u00e9se<\/strong><\/p>\n<p>Ellen\u0151rizze a vezet\u00e9keket a k\u00f6vetkez\u0151k szempontj\u00e1b\u00f3l:<\/p>\n<ul>\n<li>H\u0151k\u00e1rosod\u00e1s (elsz\u00ednez\u0151d\u00e9s, t\u00f6r\u00e9kenys\u00e9g)<\/li>\n<li>Megfelel\u0151 vezet\u00e9khossz az \u00faj csatlakoz\u00e1sokhoz<\/li>\n<li>Megfelel\u0151 szigetel\u00e9si \u00e1llapot<\/li>\n<li>Megfelel\u0151 m\u00e9r\u0151eszk\u00f6z az \u00e1ramk\u00f6r terhel\u00e9s\u00e9hez<\/li>\n<\/ul>\n<h3>2. f\u00e1zis: M\u0171szaki bek\u00f6t\u00e9si elj\u00e1r\u00e1sok<\/h3>\n<p><strong>4. Karmester el\u0151k\u00e9sz\u00edt\u00e9se<\/strong><\/p>\n<ul>\n<li>Csupasz\u00edtson le 12 mm szigetel\u00e9st megfelel\u0151 k\u00e1belcsupasz\u00edt\u00f3 fog\u00f3kkal<\/li>\n<li>\u00dcgyeljen arra, hogy a csupasz\u00edt\u00e1s sor\u00e1n ne szakadjon el r\u00e9zsz\u00e1l<\/li>\n<li>Dupla vezet\u0151r\u00e9teg a jobb csatlakoz\u00f3fog\u00e1s \u00e9rdek\u00e9ben (kritikus a 2,5 mm\u00b2-es sodrott k\u00e1belekn\u00e9l)<\/li>\n<li>Vigyen fel z\u00f6ld\/s\u00e1rga v\u00e9d\u0151burkolatot a f\u00f6ldel\u0151vezet\u00e9kekre, ha csupasz r\u00e9z l\u00e1that\u00f3.<\/li>\n<\/ul>\n<p><strong>5. Polariz\u00e1lt csatlakoz\u00e1si protokoll<\/strong><\/p>\n<p>A vezet\u00e9kek csatlakoztat\u00e1sa szigor\u00fa polariz\u00e1ci\u00f3s k\u00f6vetelm\u00e9nyeknek megfelel\u0151en:<\/p>\n<ul>\n<li><strong>\u00c9L\u0150 (barna)<\/strong> \u2192 L csatlakoz\u00f3 (jobb oldal, ha a foglalat fel\u00e9 n\u00e9z)<\/li>\n<li><strong>SEMLEGES (k\u00e9k)<\/strong> \u2192 N-termin\u00e1l (bal oldal)<\/li>\n<li><strong>F\u00d6LD (z\u00f6ld\/s\u00e1rga)<\/strong> \u2192 E termin\u00e1l (fels\u0151-k\u00f6z\u00e9ps\u0151)<\/li>\n<\/ul>\n<p><strong>Fontos a gy\u0171r\u0171s \u00e1ramk\u00f6r\u00f6kh\u00f6z:<\/strong> A legt\u00f6bb brit h\u00e1ztart\u00e1si konnektor gy\u0171r\u0171s \u00e1ramk\u00f6r\u0171, ami azt jelenti, hogy k\u00e9t k\u00e1bellel kell rendelkeznie (mindegyik sz\u00ednb\u0151l n\u00e9gy vezet\u00e9k). Minden csatlakoz\u00f3 k\u00e9t azonos sz\u00edn\u0171 vezet\u00e9ket fogad be.<\/p>\n<p><strong>6. Termin\u00e1lcsatlakoz\u00e1sok specifik\u00e1ci\u00f3i<\/strong><\/p>\n<ul>\n<li><strong>Csatlakoz\u00f3csavarok nyomat\u00e9ka:<\/strong> 0,5\u20130,6 Nm (a t\u00falzott megh\u00faz\u00e1s a sz\u00e1lak elny\u00edr\u00e1s\u00e1t okozhatja)<\/li>\n<li>Gy\u0151z\u0151dj\u00f6n meg arr\u00f3l, hogy a r\u00e9zmag a csavar alatt van r\u00f6gz\u00edtve, nem a szigetel\u00e9s alatt<\/li>\n<li>Ellen\u0151rizze, hogy a csupasz r\u00e9z nem ny\u00falik-e t\u00fal a csatlakoz\u00f3bemeneten.<\/li>\n<li>A k\u00e1belk\u00f6peny r\u00f6gz\u00edt\u00e9s\u00e9vel a szor\u00edt\u00f3lemez alatt megfelel\u0151 fesz\u00fclts\u00e9gmentes\u00edt\u00e9st kell biztos\u00edtani<\/li>\n<\/ul>\n<h3>3. f\u00e1zis: Aljzat felszerel\u00e9se \u00e9s be\u00e1ll\u00edt\u00e1sa<\/h3>\n<p><strong>7. Professzion\u00e1lis szerel\u00e9si technika<\/strong><\/p>\n<ul>\n<li>Haszn\u00e1ljon v\u00edzm\u00e9rt\u00e9ket a v\u00edzszintes helyzet biztos\u00edt\u00e1s\u00e1hoz<\/li>\n<li><strong>El\u0151lap csavarj\u00e1nak nyomat\u00e9ka:<\/strong> 0,8 Nm a reped\u00e9sek megel\u0151z\u00e9s\u00e9re<\/li>\n<li>Gy\u0151z\u0151dj\u00f6n meg arr\u00f3l, hogy a konnektor egy s\u00edkban van a fal fel\u00fclet\u00e9vel<\/li>\n<li>Ellen\u0151rizze a megfelel\u0151 vezet\u00e9kelvezet\u00e9st a pattress dobozban<\/li>\n<\/ul>\n<h2>Telep\u00edt\u00e9s ut\u00e1ni tesztel\u00e9s \u00e9s ellen\u0151rz\u00e9s<\/h2>\n<h3>Elektromos vizsg\u00e1lati protokoll<\/h3>\n<p><strong>1. Folytonoss\u00e1gvizsg\u00e1lat<\/strong><\/p>\n<ul>\n<li><strong>F\u00f6ldel\u00e9si ellen\u00e1ll\u00e1s:<\/strong> \u22641,1 \u03a9 (BS 7671 411.5. szab\u00e1lyoz\u00e1s)<\/li>\n<li><strong>Semleges-f\u00f6ld:<\/strong> Gy\u0151z\u0151dj\u00f6n meg arr\u00f3l, hogy nincs v\u00e9letlen k\u00f6t\u00e9s<\/li>\n<li>Kalibr\u00e1lt digit\u00e1lis multim\u00e9terrel v\u00e9gzett teszt<\/li>\n<\/ul>\n<p><strong>2. Szigetel\u00e9si ellen\u00e1ll\u00e1s vizsg\u00e1lata<\/strong><\/p>\n<ul>\n<li><strong>Minimumk\u00f6vetelm\u00e9ny:<\/strong> \u22651 M\u03a9 az f\u00e1zis\/nulla \u00e9s a f\u00f6ld k\u00f6z\u00f6tt<\/li>\n<li>Tesztel\u00e9s 500 V DC szigetel\u00e9svizsg\u00e1l\u00f3val (megger)<\/li>\n<\/ul>\n<p><strong>3. Funkcion\u00e1lis ellen\u0151rz\u00e9s<\/strong><\/p>\n<ul>\n<li>A red\u0151ny m\u0171k\u00f6d\u00e9s\u00e9nek ellen\u0151rz\u00e9se BS 1363 tesztdug\u00f3val<\/li>\n<li>Terhel\u00e9si vizsg\u00e1lat elv\u00e9gz\u00e9se megfelel\u0151 pr\u00f3bababa terhel\u00e9ssel<\/li>\n<li>Haszn\u00e1ljon dugaszol\u00f3aljzat-tesztel\u0151t a helyes bek\u00f6t\u00e9si sorrend ellen\u0151rz\u00e9s\u00e9hez<\/li>\n<\/ul>\n<h3>Aljzattesztel\u0151 ellen\u0151rz\u00e9se<\/h3>\n<p>A dugaszol\u00f3aljzat-tesztel\u0151 a k\u00f6vetkez\u0151ket fogja jelezni:<\/p>\n<ul>\n<li>Helyes f\u00e1zis-, nulla- \u00e9s f\u00f6ldel\u00e9si csatlakoz\u00e1sok<\/li>\n<li>Megfelel\u0151 polarit\u00e1s (f\u00e1zis \u00e9s nulla nem felcser\u00e9lve)<\/li>\n<li>F\u00f6ldfolytonoss\u00e1g \u00e9s funkcionalit\u00e1s<\/li>\n<li>Gyakori vezet\u00e9kez\u00e9si hib\u00e1k, amelyek biztons\u00e1gi kock\u00e1zatot jelenthetnek<\/li>\n<\/ul>\n<h2>Speci\u00e1lis konfigur\u00e1ci\u00f3k \u00e9s modern friss\u00edt\u00e9sek<\/h2>\n<h3>Intelligens aljzat integr\u00e1ci\u00f3<\/h3>\n<p>A modern BS 1363-kompatibilis aljzatok mostant\u00f3l t\u00e1mogatj\u00e1k:<\/p>\n<ul>\n<li><strong>Energiafigyel\u00e9s:<\/strong> Fesz\u00fclts\u00e9g (230V \u00b110%), \u00e1ram (0\u201313A) \u00e9s teljes\u00edtm\u00e9nyt\u00e9nyez\u0151 val\u00f3s idej\u0171 m\u00e9r\u00e9se<\/li>\n<li><strong>T\u00e1vir\u00e1ny\u00edt\u00f3:<\/strong> Zigbee\/802.15.4 vezet\u00e9k n\u00e9lk\u00fcli integr\u00e1ci\u00f3 otthoni automatiz\u00e1l\u00e1shoz<\/li>\n<li><strong>USB-C t\u00e1pell\u00e1t\u00e1s:<\/strong> Ak\u00e1r 45 W-os USB-C portok dinamikus fesz\u00fclts\u00e9gegyeztet\u00e9ssel (5\u201320 V)<\/li>\n<li><strong>Alkalmaz\u00e1skapcsolat:<\/strong> Okostelefonos vez\u00e9rl\u00e9s \u00e9s \u00fctemez\u00e9si lehet\u0151s\u00e9gek<\/li>\n<\/ul>\n<h3>USB-aljzattal kapcsolatos szempontok<\/h3>\n<p>USB-be \u00e9p\u00edtett aljzatokra val\u00f3 friss\u00edt\u00e9s eset\u00e9n:<\/p>\n<ul>\n<li>Fenntartja a kompatibilit\u00e1st a megl\u00e9v\u0151 BS 1363 szabv\u00e1nnyal<\/li>\n<li>Vegye figyelembe a t\u00f6lt\u00e9si k\u00f6vetelm\u00e9nyeket (USB-A vs. USB-C)<\/li>\n<li>Ellen\u0151rizze a megl\u00e9v\u0151 patchboxon bel\u00fcli elegend\u0151 helyet<\/li>\n<li>K\u00f6vesse ugyanazokat a bek\u00f6t\u00e9si elj\u00e1r\u00e1sokat, mint a hagyom\u00e1nyos aljzatok<\/li>\n<\/ul>\n<h2>Gyakori telep\u00edt\u00e9si probl\u00e9m\u00e1k elh\u00e1r\u00edt\u00e1sa<\/h2>\n<h3>Nincs \u00e1ram a telep\u00edt\u00e9s ut\u00e1n<\/h3>\n<p><strong>Azonnali int\u00e9zked\u00e9sek:<\/strong><\/p>\n<ol>\n<li><strong>AZONNAL KAPCSOLJA KI<\/strong> \u00e9s halottnak bizonyul<\/li>\n<li>Ellen\u0151rizze, hogy a kismegszak\u00edt\u00f3 (MCB) leoldott-e (r\u00f6vidz\u00e1rlatra utalva).<\/li>\n<li>Ellen\u0151rizze, hogy minden vezet\u00e9kcsatlakoz\u00e1s biztons\u00e1gos \u00e9s megfelel\u0151en van-e lez\u00e1rva<\/li>\n<li>Gy\u0151z\u0151dj\u00f6n meg arr\u00f3l, hogy a csupasz vezet\u00e9kek nem \u00e9rnek egym\u00e1shoz vagy a f\u00e9m \u00e9rintkez\u0151dobozhoz.<\/li>\n<\/ol>\n<h3>A konnektor teszter hib\u00e1kat mutat<\/h3>\n<p><strong>Gyakori indik\u00e1ci\u00f3k:<\/strong><\/p>\n<ul>\n<li><strong>Nincs F\u00f6ld:<\/strong> Vesz\u00e9lyes \u00e1llapot, amely azonnali beavatkoz\u00e1st ig\u00e9nyel<\/li>\n<li><strong>Ford\u00edtott polarit\u00e1s:<\/strong> F\u00e1zis \u00e9s nulla vezet\u00e9kek felcser\u00e9lve<\/li>\n<li><strong>Nincs semleges:<\/strong> Hi\u00e1nyos \u00e1ramk\u00f6ri csatlakoz\u00e1s<\/li>\n<\/ul>\n<p><strong>V\u00e1lasz:<\/strong> Azonnal kapcsolja ki az \u00e1ramell\u00e1t\u00e1st, \u00e9s ellen\u0151rizze \u00fajra az \u00f6sszes csatlakoz\u00e1st. Ha bizonytalan, forduljon szakk\u00e9pzett villanyszerel\u0151h\u00f6z.<\/p>\n<h3>Id\u0151szakos m\u0171k\u00f6d\u00e9s<\/h3>\n<p>A lehets\u00e9ges okok a k\u00f6vetkez\u0151k:<\/p>\n<ul>\n<li>Laza csatlakoz\u00f3k<\/li>\n<li>S\u00e9r\u00fclt vezet\u0151k a falakon bel\u00fcl<\/li>\n<li>\u00c1ramk\u00f6r t\u00falterhel\u00e9si felt\u00e9telek<\/li>\n<li>Rossz csatlakoz\u00e1s a fogyaszt\u00f3i egys\u00e9gn\u00e9l<\/li>\n<\/ul>\n<h2>Gyakori telep\u00edt\u00e9si hib\u00e1k \u00e9s megel\u0151z\u00e9s\u00fck<\/h2>\n<table>\n<thead>\n<tr>\n<th>Hiba<\/th>\n<th>Kock\u00e1zat<\/th>\n<th>Megel\u0151z\u00e9si strat\u00e9gia<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Ford\u00edtott polariz\u00e1ci\u00f3 (L\/N csere)<\/td>\n<td>Berendez\u00e9sk\u00e1rosod\u00e1s, \u00e1ram\u00fct\u00e9s vesz\u00e9lye<\/td>\n<td>Haszn\u00e1ljon csatlakoz\u00f3tesztel\u0151t; ellen\u0151rizze a barna \u2192 L, k\u00e9k \u2192 N poz\u00edci\u00f3t<\/td>\n<\/tr>\n<tr>\n<td>Nem megfelel\u0151 fesz\u00fclts\u00e9gmentes\u00edt\u00e9s<\/td>\n<td>Vezet\u0151f\u00e1rad\u00e1s, \u00edvk\u00e9pz\u0151d\u00e9s<\/td>\n<td>K\u00e1belk\u00f6peny-r\u00f6gz\u00edt\u00e9s dupla ellen\u0151rz\u00e9se<\/td>\n<\/tr>\n<tr>\n<td>Hi\u00e1nyz\u00f3 f\u00f6ldel\u00e9s<\/td>\n<td>Hiba\u00e1ram-megtart\u00e1s<\/td>\n<td>Ellen\u0151rizze a f\u00f6ldel\u00e9s folytonoss\u00e1g\u00e1t &lt;0,05 \u03a9 a f\u0151 f\u00f6ldel\u0151 csatlakoz\u00f3hoz k\u00e9pest<\/td>\n<\/tr>\n<tr>\n<td>T\u00falh\u00fazott csatlakoz\u00f3k<\/td>\n<td>Vezet\u0151 s\u00e9r\u00fcl\u00e9se<\/td>\n<td>Haszn\u00e1ljon nyomat\u00e9kkorl\u00e1toz\u00f3 csavarh\u00faz\u00f3kat<\/td>\n<\/tr>\n<tr>\n<td>Nem elegend\u0151 vezet\u00e9khossz<\/td>\n<td>Csatlakoz\u00e1si fesz\u00fclts\u00e9g<\/td>\n<td>Hagyjon elegend\u0151 vezet\u00e9khosszt a csatlakoz\u00e1sokhoz<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Mikor kell h\u00edvni egy profi villanyszerel\u0151t<\/h2>\n<p><strong>K\u00f6telez\u0151 szakmai seg\u00edts\u00e9gny\u00fajt\u00e1s:<\/strong><\/p>\n<ul>\n<li>B\u00e1rmilyen bizonytalans\u00e1g a biztons\u00e1gi elj\u00e1r\u00e1sokkal vagy szab\u00e1lyoz\u00e1sokkal kapcsolatban<\/li>\n<li>R\u00e9gi, s\u00e9r\u00fclt vagy nem megfelel\u0151 vezet\u00e9kek felder\u00edt\u00e9se<\/li>\n<li>A fogyaszt\u00f3i egys\u00e9g nem rendelkezik RCD-v\u00e9delemmel<\/li>\n<li>A munk\u00e1latokhoz P. r\u00e9sz szerinti \u00e9p\u00edt\u00e9si enged\u00e9lyez\u00e9si \u00e9rtes\u00edt\u00e9s sz\u00fcks\u00e9ges.<\/li>\n<li>A telep\u00edt\u00e9s \u00faj \u00e1ramk\u00f6r\u00f6ket vagy jelent\u0151s b\u0151v\u00edt\u00e9seket ig\u00e9nyel<\/li>\n<li>Kereskedelmi vagy b\u00e9rbead\u00e1si ingatlanok telep\u00edt\u00e9se<\/li>\n<\/ul>\n<p><strong>Azonnali szakmai beavatkoz\u00e1st ig\u00e9nyl\u0151 jelek:<\/strong><\/p>\n<ul>\n<li>Gyakran kiold\u00f3 megszak\u00edt\u00f3k<\/li>\n<li>\u00c9gett szagok az elektromos berendez\u00e9sekb\u0151l<\/li>\n<li>Meleg vagy forr\u00f3 aljzatfel\u00fcletek norm\u00e1l m\u0171k\u00f6d\u00e9s k\u00f6zben<\/li>\n<li>L\u00e1that\u00f3 szikr\u00e1z\u00e1s eszk\u00f6z\u00f6k csatlakoztat\u00e1sakor<\/li>\n<li>B\u00e1rmilyen \u00e1ram\u00fct\u00e9s elektromos berendez\u00e9sb\u0151l<\/li>\n<\/ul>\n<h2>Karbantart\u00e1s \u00e9s hossz\u00fa t\u00e1v\u00fa biztons\u00e1g<\/h2>\n<h3>Rendszeres ellen\u0151rz\u00e9si \u00fctemterv<\/h3>\n<ul>\n<li><strong>Szemrev\u00e9telez\u00e9s:<\/strong> 6 havonta s\u00e9r\u00fcl\u00e9s, kop\u00e1s vagy elsz\u00ednez\u0151d\u00e9s szempontj\u00e1b\u00f3l<\/li>\n<li><strong>Szakmai tesztel\u00e9s:<\/strong> EICR (Elektromos Telep\u00edt\u00e9si \u00c1llapotjelent\u00e9s) 5-10 \u00e9vente lakoss\u00e1gi ingatlanok eset\u00e9ben<\/li>\n<li><strong>Azonnali csere:<\/strong> B\u00e1rmilyen t\u00falmeleged\u00e9s, reped\u00e9s vagy mechanikai s\u00e9r\u00fcl\u00e9s jeleit keresve<\/li>\n<\/ul>\n<h3>Terhel\u00e9skezel\u00e9si bev\u00e1lt gyakorlatok<\/h3>\n<ul>\n<li>Ker\u00fclje a konnektorok t\u00falterhel\u00e9s\u00e9t t\u00f6bb nagy teljes\u00edtm\u00e9ny\u0171 k\u00e9sz\u00fcl\u00e9kkel<\/li>\n<li>Gy\u0151z\u0151dj\u00f6n meg arr\u00f3l, hogy a csatlakoz\u00f3dug\u00f3k szorosan illeszkednek (a laza csatlakoz\u00e1sok t\u00falmeleged\u00e9st okozhatnak)<\/li>\n<li>A t\u00falterhel\u00e9s megel\u0151z\u00e9se \u00e9rdek\u00e9ben figyelje a teljes \u00e1ramk\u00f6r terhel\u00e9s\u00e9t<\/li>\n<li>Fontolja meg az \u00e1ramk\u00f6r b\u0151v\u00edt\u00e9s\u00e9t, ha gyakran haszn\u00e1lja a maxim\u00e1lis kapacit\u00e1st<\/li>\n<\/ul>\n<h2>K\u00f6vetkeztet\u00e9s<\/h2>\n<p>A brit szabv\u00e1ny\u00fa kapcsol\u00f3aljzatok telep\u00edt\u00e9se \u00f6tv\u00f6zi a t\u00f6rt\u00e9nelmi biztons\u00e1gi \u00faj\u00edt\u00e1sokat a modern technol\u00f3giai k\u00f6vetelm\u00e9nyekkel. Az 1944-es h\u00e1bor\u00fa ut\u00e1ni \u00fajj\u00e1\u00e9p\u00edt\u00e9si ig\u00e9nyek alapj\u00e1n kifejlesztett BS 1363 rendszer megfelel\u0151 telep\u00edt\u00e9s \u00e9s karbantart\u00e1s eset\u00e9n a vil\u00e1g egyik legbiztons\u00e1gosabb elektromos aljzat-kialak\u00edt\u00e1sa.<\/p>\n<p>A siker a biztons\u00e1gi protokollok szigor\u00fa betart\u00e1s\u00e1t\u00f3l, az Egyes\u00fclt Kir\u00e1lys\u00e1g k\u00e1belez\u00e9si szabv\u00e1nyainak meg\u00e9rt\u00e9s\u00e9t\u0151l \u00e9s a szakmai k\u00e9pess\u00e9gek korl\u00e1tainak felismer\u00e9s\u00e9t\u0151l f\u00fcgg. A \u201epr\u00f3b\u00e1ld meg, pr\u00f3b\u00e1ld meg az egys\u00e9get, pr\u00f3b\u00e1ld meg a kikapcsolt \u00e1llapotot\u201d tesztel\u00e9si m\u00f3dszer, a csatlakoz\u00e1sok megfelel\u0151 polariz\u00e1ci\u00f3ja \u00e9s az \u00e1tfog\u00f3 telep\u00edt\u00e9s ut\u00e1ni ellen\u0151rz\u00e9s biztos\u00edtja, hogy a telep\u00edt\u00e9sek megfeleljenek a BS 7671 szabv\u00e1ny k\u00f6vetelm\u00e9nyeinek.<\/p>\n<p>Ak\u00e1r hasonl\u00f3 alkatr\u00e9szek cser\u00e9j\u00e9t v\u00e9gzi, ak\u00e1r modern intelligens aljzatok korszer\u0171s\u00edt\u00e9s\u00e9t fontolgatja, a biztons\u00e1got a megfelel\u0151 szigetel\u00e9si elj\u00e1r\u00e1sok, a helyes bek\u00f6t\u00e9si technik\u00e1k \u00e9s a bizonytalans\u00e1g eset\u00e9n a szakmai konzult\u00e1ci\u00f3 r\u00e9v\u00e9n kell el\u0151t\u00e9rbe helyezni. A GFCI integr\u00e1ci\u00f3 \u00e9s az intelligens otthoni csatlakoztathat\u00f3s\u00e1g j\u00f6v\u0151beli fejleszt\u00e9sei tov\u00e1bbra is b\u0151v\u00edtik a funkcionalit\u00e1st, mik\u00f6zben fenntartj\u00e1k a BS 1363 szabv\u00e1ny bev\u00e1lt biztons\u00e1gi alapjait.<\/p>\n<p><strong>Biztons\u00e1gi nyilatkozat:<\/strong> Ez az \u00fatmutat\u00f3 kiz\u00e1r\u00f3lag oktat\u00e1si c\u00e9l\u00fa inform\u00e1ci\u00f3kat tartalmaz. Az elektromos munk\u00e1k jelent\u0151s biztons\u00e1gi kock\u00e1zatokkal j\u00e1rnak, \u00e9s a helyi \u00e9p\u00edt\u00e9si el\u0151\u00edr\u00e1sokt\u00f3l, a telep\u00edt\u00e9s \u00f6sszetetts\u00e9g\u00e9t\u0151l \u00e9s az egy\u00e9ni kompetenciaszintekt\u0151l f\u00fcgg\u0151en szakember telep\u00edt\u00e9s\u00e9t ig\u00e9nyelhetik. Komplex telep\u00edt\u00e9sek, kereskedelmi munk\u00e1k vagy a telep\u00edt\u00e9si folyamat b\u00e1rmely aspektus\u00e1val kapcsolatos bizonytalans\u00e1g eset\u00e9n mindig konzult\u00e1ljon szakk\u00e9pzett villanyszerel\u0151vel.<\/p>\n<h2>Kapcsol\u00f3d\u00f3<\/h2>\n<p><a href=\"https:\/\/test.viox.com\/hu\/uk-switch-and-socket\/\">Az egyes\u00fclt KIR\u00c1LYS\u00c1G Kapcsol\u00f3 csatlakoz\u00f3<\/a><\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Installing a British standard switch socket requires understanding UK electrical regulations, safety protocols, and proper wiring techniques. This comprehensive guide covers everything from historical context to advanced installation procedures, ensuring safe and compliant socket installation following BS 1363 standards. What Are British Standard Switch Sockets? VIOX British standard sockets British standard sockets (BS 1363) represent [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":17390,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1],"tags":[],"class_list":["post-17389","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"_links":{"self":[{"href":"https:\/\/test.viox.com\/hu\/wp-json\/wp\/v2\/posts\/17389","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/test.viox.com\/hu\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/test.viox.com\/hu\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/test.viox.com\/hu\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/test.viox.com\/hu\/wp-json\/wp\/v2\/comments?post=17389"}],"version-history":[{"count":0,"href":"https:\/\/test.viox.com\/hu\/wp-json\/wp\/v2\/posts\/17389\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/test.viox.com\/hu\/wp-json\/wp\/v2\/media\/17390"}],"wp:attachment":[{"href":"https:\/\/test.viox.com\/hu\/wp-json\/wp\/v2\/media?parent=17389"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/test.viox.com\/hu\/wp-json\/wp\/v2\/categories?post=17389"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/test.viox.com\/hu\/wp-json\/wp\/v2\/tags?post=17389"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}