{"id":5465,"date":"2024-09-12T15:13:20","date_gmt":"2024-09-12T07:13:20","guid":{"rendered":"https:\/\/viox.com\/?post_type=product&#038;p=5465"},"modified":"2024-09-12T15:17:32","modified_gmt":"2024-09-12T07:17:32","slug":"viox-vsp1-d20-1s1-pluggable-single-pole-spd","status":"publish","type":"product","link":"https:\/\/test.viox.com\/fr\/produit\/viox-vsp1-d20-1s1-pluggable-single-pole-spd\/","title":{"rendered":"VIOX VSP1-D20\/1(S)+1 SPD unipolaire enfichable"},"content":{"rendered":"<div class=\"product-intro\">\n<h2>VIOX VSP1-D20\/1(S)+1 Pluggable Single-Pole SPD<\/h2>\n<h2>Overview<\/h2>\n<p>The VIOX VSP1-D20\/1(S)+1 is a high-performance Pluggable Single-Pole Surge Protective Device (SPD) designed for use in sub-distribution boards. This versatile device offers robust protection for L-N and N-PE modes, making it an ideal solution for various electrical installations.<\/p>\n<h2>Key Features<\/h2>\n<ul>\n<li>Class II, Class III, Type 2, Type 3 device<\/li>\n<li>Location of Use: Sub-Distribution Boards<\/li>\n<li>Mode of Protection: L-N, N-PE<\/li>\n<li>Surge Ratings: In = 10 kA (8\/20 \u03bcs)<\/li>\n<li>IEC\/EN\/UL Category: Class II+III \/ Type 2+3<\/li>\n<li>Protective Elements: High Energy MOV and GDT<\/li>\n<li>Housing: Pluggable Design<\/li>\n<li>Compliance: IEC 61643-11:2011, EN 61643-11:2012<\/li>\n<\/ul>\n<h2>Technical Specifications<\/h2>\n<table border=\"1\" cellpadding=\"5\">\n<tbody>\n<tr>\n<th>IEC Electrical<\/th>\n<th>75<\/th>\n<th>150<\/th>\n<th>275<\/th>\n<th>320<\/th>\n<th>385<\/th>\n<th>440<\/th>\n<\/tr>\n<tr>\n<td>Nominal AC Voltage (50\/60Hz)<\/td>\n<td>60 V<\/td>\n<td>120 V<\/td>\n<td>230 V<\/td>\n<td>230 V<\/td>\n<td>230 V<\/td>\n<td>400 V<\/td>\n<\/tr>\n<tr>\n<td>Maximum Continuous Operating Voltage (AC) (L-N)<\/td>\n<td>75 V<\/td>\n<td>150 V<\/td>\n<td>275V<\/td>\n<td>320 V<\/td>\n<td>385 V<\/td>\n<td>440 V<\/td>\n<\/tr>\n<tr>\n<td>Maximum Continuous Operating Voltage (AC) (N-PE)<\/td>\n<td colspan=\"6\">255V<\/td>\n<\/tr>\n<tr>\n<td>Nominal Discharge Current (8\/20 \u03bcs) (L-N) \/ (N-PE)<\/td>\n<td colspan=\"6\">10kV \/ 10kA<\/td>\n<\/tr>\n<tr>\n<td>Maximum Discharge Current (8\/20 \u03bcs) (L-N) \/ (N-PE)<\/td>\n<td colspan=\"6\">20 kA \/ 20 kA<\/td>\n<\/tr>\n<tr>\n<td>Voltage Protection Level (L-N) \/ (N-PE)<\/td>\n<td>0.2kV\/1.5kV<\/td>\n<td>0.6kV\/1.5kV<\/td>\n<td>1.3kV\/1.5kV<\/td>\n<td>1.5kV\/1.5kV<\/td>\n<td>1.5kV\/1.5kV<\/td>\n<td>1.8kV\/1.5kV<\/td>\n<\/tr>\n<tr>\n<td>Follow Current Interrupt Rating (N-PE)<\/td>\n<td colspan=\"6\">100Arms<\/td>\n<\/tr>\n<tr>\n<td>Response Time (L-N) \/ (N-PE)<\/td>\n<td colspan=\"6\">&lt; 25 ns \/ &lt; 100 ns<\/td>\n<\/tr>\n<tr>\n<td>Back-Up Fuse (max)<\/td>\n<td colspan=\"6\">125 A gL \/ gG<\/td>\n<\/tr>\n<tr>\n<td>Short-Circuit Current Rating (AC) (L-N)<\/td>\n<td colspan=\"6\">10 kA<\/td>\n<\/tr>\n<tr>\n<td>TOV Withstand 5s (L-N)<\/td>\n<td>90V<\/td>\n<td>180V<\/td>\n<td>335V<\/td>\n<td>335V<\/td>\n<td>335V<\/td>\n<td>580V<\/td>\n<\/tr>\n<tr>\n<td>TOV 120min (L-N)<\/td>\n<td>115V<\/td>\n<td>230V<\/td>\n<td>440V<\/td>\n<td>440V<\/td>\n<td>440V<\/td>\n<td>765V<\/td>\n<\/tr>\n<tr>\n<td>mode<\/td>\n<td>Withstand<\/td>\n<td>Withstand<\/td>\n<td>Safe Fail<\/td>\n<td>Safe Fail<\/td>\n<td>Safe Fail<\/td>\n<td>Safe Fail<\/td>\n<\/tr>\n<tr>\n<td>TOV Withstand 200ms (N-PE)<\/td>\n<td colspan=\"6\">1200V<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Mechanical &amp; Environmental Specifications<\/h2>\n<ul>\n<li>Operating Temperature Range: -40\u00b0F to +158\u00b0F [-40\u00b0C to +70\u00b0C]<\/li>\n<li>Permissible Operating Humidity: 5%&#8230;95%<\/li>\n<li>Atmospheric pressure and altitude: 80k Pa &#8230; 106k Pa \/ -500 m&#8230;.2000 m<\/li>\n<li>Terminal Screw Torque: 39.9 lbf.in [4.5 Nm]<\/li>\n<li>Conductor Cross Section (max): 2 AWG (Solid, Stranded) \/ 4 AWG (Flexible)<\/li>\n<li>35 mm\u00b2 (Solid, Stranded) \/ 25 mm\u00b2(Flexible)<\/li>\n<li>Mounting: 35 mm DIN Rail, EN 60715<\/li>\n<li>Degree of Protection: IP 20 (built-in)<\/li>\n<li>Housing Material: Thermoplastic: Extinguishing Degree UL 94 V-0<\/li>\n<li>Thermal Protection: Yes<\/li>\n<li>Operating State \/ Fault Indication: Green ok \/ Red defect<\/li>\n<\/ul>\n<h2>Additional Features<\/h2>\n<ul>\n<li>Remote Contacts (RC): Optional<\/li>\n<li>RC Switching Capacity: AC: 250V \/ 0.5 A; DC: 250V \/ 0.1 A; 125 V \/ 0.2 A; 75 V \/ 0.5 A<\/li>\n<li>RC Conductor Cross Section (max): 16 AWG (Solid) \/ 1.5 mm\u00b2(Solid)<\/li>\n<\/ul>\n<h2>Internal Configuration<\/h2>\n<p><a href=\"https:\/\/test.viox.com\/?attachment_id=5469\" rel=\"attachment wp-att-5469\"><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone wp-image-5469 size-full\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VSP1-D20_1S1-Pluggable-Single-Pole-SPD04.webp\" alt=\" Internal Configuration OF VIOX VSP1-D20_1(S)+1 Pluggable Single-Pole SPD\" width=\"332\" height=\"370\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VSP1-D20_1S1-Pluggable-Single-Pole-SPD04.webp 332w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VSP1-D20_1S1-Pluggable-Single-Pole-SPD04-269x300.webp 269w\" sizes=\"(max-width: 332px) 100vw, 332px\" \/><\/a><\/p>\n<h2>Dimension<\/h2>\n<p><a href=\"https:\/\/test.viox.com\/?attachment_id=5467\" rel=\"attachment wp-att-5467\"><img decoding=\"async\" class=\"alignnone size-full wp-image-5467\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VSP1-D20_1S1-Pluggable-Single-Pole-SPD03.webp\" alt=\"Dimension of VIOX VSP1-D20_1(S)+1 Pluggable Single-Pole SPD\" width=\"696\" height=\"368\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VSP1-D20_1S1-Pluggable-Single-Pole-SPD03.webp 696w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VSP1-D20_1S1-Pluggable-Single-Pole-SPD03-300x159.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VSP1-D20_1S1-Pluggable-Single-Pole-SPD03-600x317.webp 600w\" sizes=\"(max-width: 696px) 100vw, 696px\" \/><\/a><\/p>\n<h2>Connection Diagram<\/h2>\n<p><a href=\"https:\/\/test.viox.com\/?attachment_id=5468\" rel=\"attachment wp-att-5468\"><img decoding=\"async\" class=\"alignnone size-full wp-image-5468\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VSP1-D20_1S1-Pluggable-Single-Pole-SPD02.webp\" alt=\" Connection Diagram of VIOX VSP1-D20_1(S)+1 Pluggable Single-Pole SPD\" width=\"430\" height=\"462\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VSP1-D20_1S1-Pluggable-Single-Pole-SPD02.webp 430w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VSP1-D20_1S1-Pluggable-Single-Pole-SPD02-279x300.webp 279w\" sizes=\"(max-width: 430px) 100vw, 430px\" \/><\/a><\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<div class=\"msg-content MuiBox-root css-0\">\n<div class=\"break-words\">\n<p>VIOX VSP1-D20\/1(S)+1 Pluggable Single-Pole SPD offre une protection compl\u00e8te contre les surtensions pour les cartes de sous-distribution. Ce dispositif de Classe II+III\/Type 2+3 prot\u00e8ge les modes L-N et N-PE avec un courant de d\u00e9charge nominal de 10kA et maximum de 20kA. Dot\u00e9 d'\u00e9l\u00e9ments MOV et GDT \u00e0 haute \u00e9nergie, il fonctionne de 60V \u00e0 400V AC avec un temps de r\u00e9ponse &lt;25ns pour L-N et &lt;100ns pour N-PE. Conforme aux normes IEC 61643-11:2011 et EN 61643-11:2012, il offre des niveaux de protection de 0,2kV \u00e0 1,8kV. Avec une protection IP20, des protections thermiques et des contacts \u00e0 distance en option, ce SPD polyvalent convient \u00e0 diverses installations \u00e9lectriques, combinant fiabilit\u00e9 et performance pour une meilleure protection du syst\u00e8me d&#039;alimentation dans diverses applications.<\/p>\n<\/div>\n<\/div>","protected":false},"featured_media":5466,"comment_status":"closed","ping_status":"closed","template":"","meta":{"inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[],"product_cat":[116,127],"product_tag":[],"class_list":{"0":"post-5465","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-low-voltage-protection-devices","7":"product_cat-surge-protector","8":"desktop-align-left","9":"tablet-align-left","10":"mobile-align-left","12":"first","13":"instock","14":"shipping-taxable","15":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/test.viox.com\/fr\/wp-json\/wp\/v2\/product\/5465","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/test.viox.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/test.viox.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/test.viox.com\/fr\/wp-json\/wp\/v2\/comments?post=5465"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/test.viox.com\/fr\/wp-json\/wp\/v2\/media\/5466"}],"wp:attachment":[{"href":"https:\/\/test.viox.com\/fr\/wp-json\/wp\/v2\/media?parent=5465"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/test.viox.com\/fr\/wp-json\/wp\/v2\/product_brand?post=5465"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/test.viox.com\/fr\/wp-json\/wp\/v2\/product_cat?post=5465"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/test.viox.com\/fr\/wp-json\/wp\/v2\/product_tag?post=5465"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}