{"id":3796,"date":"2024-06-21T13:14:47","date_gmt":"2024-06-21T05:14:47","guid":{"rendered":"https:\/\/viox.com\/?post_type=product&#038;p=3796"},"modified":"2024-06-21T13:24:00","modified_gmt":"2024-06-21T05:24:00","slug":"sm8-hall-sensor","status":"publish","type":"product","link":"https:\/\/test.viox.com\/fr\/produit\/sm8-hall-sensor\/","title":{"rendered":"Capteur \u00e0 effet Hall SM8"},"content":{"rendered":"<p><em><strong>Br\u00e8ve introduction :<\/strong><\/em><\/p>\n<div>\u00a0\u00a0Le capteur \u00e0 effet Hall de la s\u00e9rie SM est un type de capteur magn\u00e9to-sensoriel compos\u00e9 d'un r\u00e9gulateur de tension, d'un g\u00e9n\u00e9rateur de tension \u00e0 effet Hall, d'un amplificateur diff\u00e9rentiel, d'un d\u00e9clencheur Schmidt et d'un p\u00f4le de sortie de collecteur en circuit ouvert. Son entr\u00e9e est la densit\u00e9 du flux magn\u00e9tique. La sortie est un signal de tension num\u00e9rique.<\/div>\n<div><\/div>\n<div><em><strong>Caract\u00e9ristiques :<\/strong><\/em><\/div>\n<div>\n<ul class=\"list-paddingleft-2\">\n<li>Large gamme de tensions secteur<\/li>\n<li>Haute fr\u00e9quence<\/li>\n<li>Longue dur\u00e9e de vie, volume compact et installation pratique<\/li>\n<li>Connexion directe \u00e0 des transistors et \u00e0 des circuits logiques tels que TTL ou MOS.<\/li>\n<\/ul>\n<div><\/div>\n<div><\/div>\n<div><em><strong>Mod\u00e8le et param\u00e8tres :<\/strong><\/em><\/div>\n<div>\n<div class=\"sliderTable mt10 mb10 sliderTable-index0\">\n<div class=\"inner\">\n<table width=\"899\">\n<tbody>\n<tr class=\"firstRow\">\n<td width=\"336\"><strong>Code d'apparence ext\u00e9rieure<\/strong><\/td>\n<td width=\"562\"><strong>SM8<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"336\"><strong>Marque<\/strong><\/td>\n<td width=\"562\"><b>VIOX<\/b><\/td>\n<\/tr>\n<tr>\n<td width=\"336\">Distance de d\u00e9tection<\/td>\n<td width=\"562\">10 mm<\/td>\n<\/tr>\n<tr>\n<td width=\"336\">Tension secteur<\/td>\n<td width=\"562\">5-24VDC<\/td>\n<\/tr>\n<tr>\n<td width=\"336\">Objet d\u00e9tectable<\/td>\n<td width=\"562\">Aimant permanent<\/td>\n<\/tr>\n<tr>\n<td width=\"336\">Tension de bas niveau de la sortie<\/td>\n<td width=\"562\">200mV<\/td>\n<\/tr>\n<tr>\n<td width=\"336\">Tension de haut niveau de la sortie<\/td>\n<td width=\"562\">0,1\u03bcA<\/td>\n<\/tr>\n<tr>\n<td width=\"336\">Courant secteur<\/td>\n<td width=\"562\">8mA<\/td>\n<\/tr>\n<tr>\n<td width=\"336\">Fr\u00e9quence ON-OFF<\/td>\n<td width=\"562\">320KHz<\/td>\n<\/tr>\n<tr>\n<td width=\"336\">Densit\u00e9 magn\u00e9tique au point de travail<\/td>\n<td width=\"562\">22mT<\/td>\n<\/tr>\n<tr>\n<td width=\"336\">Mat\u00e9riau de la coque<\/td>\n<td width=\"562\">M\u00e9tal<\/td>\n<\/tr>\n<tr>\n<td width=\"336\">Temp\u00e9rature ambiante<\/td>\n<td width=\"562\">-25\u2103~+70\u2103<\/td>\n<\/tr>\n<tr>\n<td width=\"336\">Structure de protection<\/td>\n<td width=\"562\">IP67<\/td>\n<\/tr>\n<tr>\n<td width=\"336\">NPN NO<\/td>\n<td width=\"562\"><strong>SM8-31010NA<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"336\">NPN NC<\/td>\n<td width=\"562\">&#8211;<\/td>\n<\/tr>\n<tr>\n<td width=\"336\">PNP NO<\/td>\n<td width=\"562\">SM8-31010PA<\/td>\n<\/tr>\n<tr>\n<td width=\"336\">PNP NC<\/td>\n<td width=\"562\">&#8211;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Les capteurs \u00e0 effet Hall VIOX de la s\u00e9rie SM se caract\u00e9risent par une large plage de tension (5-24VDC), une haute fr\u00e9quence (320KHz) et une conception m\u00e9tallique compacte et durable avec une protection IP67. Ces capteurs offrent une distance de d\u00e9tection de 10 mm et se connectent directement aux circuits TTL\/MOS. Fonctionnant \u00e0 des temp\u00e9ratures de -25\u2103 \u00e0 +70\u2103, les mod\u00e8les SM8-31010NA (NPN) et SM8-31010PA (PNP) garantissent des performances fiables pour les applications industrielles.<\/p>","protected":false},"featured_media":3797,"comment_status":"closed","ping_status":"closed","template":"","meta":{"inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[],"product_cat":[81,30],"product_tag":[],"class_list":{"0":"post-3796","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-hall-sensor","7":"product_cat-sensors","8":"desktop-align-left","9":"tablet-align-left","10":"mobile-align-left","12":"first","13":"instock","14":"shipping-taxable","15":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/test.viox.com\/fr\/wp-json\/wp\/v2\/product\/3796","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/test.viox.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/test.viox.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/test.viox.com\/fr\/wp-json\/wp\/v2\/comments?post=3796"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/test.viox.com\/fr\/wp-json\/wp\/v2\/media\/3797"}],"wp:attachment":[{"href":"https:\/\/test.viox.com\/fr\/wp-json\/wp\/v2\/media?parent=3796"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/test.viox.com\/fr\/wp-json\/wp\/v2\/product_brand?post=3796"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/test.viox.com\/fr\/wp-json\/wp\/v2\/product_cat?post=3796"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/test.viox.com\/fr\/wp-json\/wp\/v2\/product_tag?post=3796"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}