{"id":20336,"date":"2025-11-27T09:48:38","date_gmt":"2025-11-27T01:48:38","guid":{"rendered":"https:\/\/viox.com\/?post_type=product&#038;p=20336"},"modified":"2025-11-27T09:52:58","modified_gmt":"2025-11-27T01:52:58","slug":"vob4-63-mcb-6ka-10ka-miniature-circuit-breaker","status":"publish","type":"product","link":"https:\/\/test.viox.com\/fr\/produit\/vob4-63-mcb-6ka-10ka-miniature-circuit-breaker\/","title":{"rendered":"VOB4-63 MCB \u2013 Disjoncteur Miniature"},"content":{"rendered":"<div class=\"product-intro\">\n<h2><\/h2>\n<h2>VOB4-63 High-Performance Miniature Circuit Breaker<\/h2>\n<p><strong>Industrial-Grade MCB with 6kA\/10kA Breaking Capacity<\/strong> &#8211; VIOX VOB4-63 series miniature circuit breakers deliver superior protection for demanding commercial and industrial installations. Dual-standard compliant (IEC 60898-1 &amp; IEC 60947-2), thermal-magnetic trip technology, 500V insulation rating, complete range from 1A to 63A.<\/p>\n<h2>Why Choose VOB4-63 High-Performance MCB?<\/h2>\n<ul>\n<li><strong>Dual Breaking Capacity:<\/strong> 6000A or 10000A &#8211; superior fault protection for industrial systems<\/li>\n<li><strong>Enhanced Insulation:<\/strong> AC 500V rated insulation voltage (higher than standard 415V)<\/li>\n<li><strong>Dual Standard Compliance:<\/strong> IEC 60898-1 &amp; IEC 60947-2 certified for both residential and industrial applications<\/li>\n<li><strong>Complete Rating Range:<\/strong> 1A to 63A in full increments (1A, 2A, 3A, 4A, 5A, 6A, 8A, 10A, 13A, 16A, 20A, 25A, 32A, 40A, 50A, 63A)<\/li>\n<li><strong>All Trip Curves Available:<\/strong> Type B, C, D curves for any application requirement<\/li>\n<li><strong>Industrial Durability:<\/strong> 10,000 mechanical operations, 4,000 electrical cycles<\/li>\n<li><strong>Professional Installation:<\/strong> DIN rail mounting, 1-25mm\u00b2 terminal capacity<\/li>\n<li><strong>Proven Quality:<\/strong> Manufactured by ISO 9001:2015 certified VIOX Electric<\/li>\n<\/ul>\n<hr \/>\n<h2>Complete Technical Specifications<\/h2>\n<table border=\"1\" cellspacing=\"0\" cellpadding=\"5\">\n<thead>\n<tr>\n<th>Parameter<\/th>\n<th>Specification<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>Product Series<\/strong><\/td>\n<td>VOB4-63<\/td>\n<\/tr>\n<tr>\n<td><strong>Breaking Capacity (Icn)<\/strong><\/td>\n<td><strong>6000A or 10000A<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>Number of Poles<\/strong><\/td>\n<td>1P, 2P, 3P, 4P<\/td>\n<\/tr>\n<tr>\n<td><strong>Rated Current (In)<\/strong><\/td>\n<td>1A, 2A, 3A, 4A, 5A, 6A, 8A, 10A, 13A, 16A, 20A, 25A, 32A, 40A, 50A, 63A<\/td>\n<\/tr>\n<tr>\n<td><strong>Rated Operational Voltage<\/strong><\/td>\n<td>1P: 240V\/415V~<br \/>\n2P, 3P, 4P: 415V~<\/td>\n<\/tr>\n<tr>\n<td><strong>Trip Unit Technology<\/strong><\/td>\n<td>Thermal-magnetic<\/td>\n<\/tr>\n<tr>\n<td><strong>Curve Code (Trip Characteristics)<\/strong><\/td>\n<td><strong>B, C, D<\/strong> (all curves available)<\/td>\n<\/tr>\n<tr>\n<td><strong>Rated Insulation Voltage (Ui)<\/strong><\/td>\n<td><strong>AC 500V~<\/strong> (enhanced)<\/td>\n<\/tr>\n<tr>\n<td><strong>Rated Impulse Withstand Voltage (Uimp)<\/strong><\/td>\n<td>4000V<\/td>\n<\/tr>\n<tr>\n<td><strong>Mechanical Durability<\/strong><\/td>\n<td>10,000 cycles<\/td>\n<\/tr>\n<tr>\n<td><strong>Electrical Durability<\/strong><\/td>\n<td>4,000 cycles<\/td>\n<\/tr>\n<tr>\n<td><strong>Tightening Torque<\/strong><\/td>\n<td>M5 2.5N\u00b7m \u26a0<\/td>\n<\/tr>\n<tr>\n<td><strong>IP Degree of Protection<\/strong><\/td>\n<td>IP20 conforming to IEC 60529<br \/>\nIP40 (modular enclosure) conforming to IEC 60529<\/td>\n<\/tr>\n<tr>\n<td><strong>Ambient Air Temperature for Operation<\/strong><\/td>\n<td>-5\u00b0C to +40\u00b0C<\/td>\n<\/tr>\n<tr>\n<td><strong>Standards Compliance<\/strong><\/td>\n<td><strong>IEC 60898-1 &amp; IEC 60947-2<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>EU RoHS Directive<\/strong><\/td>\n<td>Compliant EU RoHS Declaration<\/td>\n<\/tr>\n<tr>\n<td><strong>Pollution Degree<\/strong><\/td>\n<td>2 conforming to IEC\/EN 60898-1<\/td>\n<\/tr>\n<tr>\n<td><strong>Terminal Capacity<\/strong><\/td>\n<td>Upper\/Lower Wiring: 1-25mm\u00b2 (flexible\/rigid conductor)<\/td>\n<\/tr>\n<tr>\n<td><strong>Mounting<\/strong><\/td>\n<td>35mm DIN rail (IEC\/EN 60715)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<hr \/>\n<h2>Understanding Breaking Capacity: 6kA vs 10kA<\/h2>\n<p>The VOB4-63 series offers two breaking capacity options to match your installation requirements:<\/p>\n<h3>6kA Breaking Capacity (6000A)<\/h3>\n<ul>\n<li><strong>Best for:<\/strong> Residential buildings, small commercial offices, light industrial facilities<\/li>\n<li><strong>Typical installations:<\/strong> Lighting circuits, small motor loads, general power distribution<\/li>\n<li><strong>Fault current handling:<\/strong> Up to 6,000 amperes short-circuit protection<\/li>\n<\/ul>\n<h3>10kA Breaking Capacity (10000A) &#8211; Recommended for Industrial<\/h3>\n<ul>\n<li><strong>Best for:<\/strong> Industrial plants, large commercial buildings, high-power equipment installations<\/li>\n<li><strong>Typical installations:<\/strong> Motor control centers, industrial automation, heavy machinery protection<\/li>\n<li><strong>Fault current handling:<\/strong> Up to 10,000 amperes short-circuit protection<\/li>\n<li><strong>Additional safety margin:<\/strong> 67% higher capacity than 6kA for demanding applications<\/li>\n<\/ul>\n<p><strong>How to Choose:<\/strong> Calculate your installation&#8217;s prospective short-circuit current (PSC). For most industrial applications with transformers above 200kVA, 10kA breaking capacity is recommended.<\/p>\n<hr \/>\n<h2>Trip Curve Selection Guide<\/h2>\n<p>Select the correct trip curve based on your load characteristics:<\/p>\n<h3>Type B Curve MCB (3-5 \u00d7 In)<\/h3>\n<p><strong>Best for resistive loads with minimal inrush current:<\/strong><\/p>\n<ul>\n<li>Residential and commercial lighting circuits<\/li>\n<li>Heating elements and resistive heaters<\/li>\n<li>Domestic appliances<\/li>\n<li>Long cable runs where trip sensitivity is needed<\/li>\n<\/ul>\n<h3>Type C Curve MCB (5-10 \u00d7 In) &#8211; Most Common<\/h3>\n<p><strong>Best for general-purpose commercial and industrial applications:<\/strong><\/p>\n<ul>\n<li>Motor-driven equipment (pumps, fans, compressors)<\/li>\n<li>Fluorescent and LED lighting with electronic ballasts<\/li>\n<li>Transformers and inductive loads<\/li>\n<li>HVAC systems<\/li>\n<li>General power distribution panels<\/li>\n<\/ul>\n<h3>Type D Curve MCB (10-20 \u00d7 In)<\/h3>\n<p><strong>Best for high inrush current loads:<\/strong><\/p>\n<ul>\n<li>Large industrial motors and motor starters<\/li>\n<li>Welding equipment and X-ray machines<\/li>\n<li>Large transformers with high magnetizing inrush<\/li>\n<li>Capacitive loads<\/li>\n<li>Industrial machinery with high starting currents<\/li>\n<\/ul>\n<hr \/>\n<h2>Applications by Industry<\/h2>\n<h3>Industrial Manufacturing<\/h3>\n<ul>\n<li>Motor control centers (MCCs) for production equipment<\/li>\n<li>CNC machines and industrial automation systems<\/li>\n<li>Conveyor systems and material handling equipment<\/li>\n<li>Industrial robots and automated assembly lines<\/li>\n<li>Power distribution in factory electrical panels<\/li>\n<\/ul>\n<h3>Commercial Buildings<\/h3>\n<ul>\n<li>Office building main and sub-distribution boards<\/li>\n<li>Shopping mall electrical systems<\/li>\n<li>Hotel and hospitality power distribution<\/li>\n<li>Data center electrical protection<\/li>\n<li>Commercial HVAC and mechanical systems<\/li>\n<\/ul>\n<h3>Infrastructure &amp; Construction<\/h3>\n<ul>\n<li>Public building electrical installations<\/li>\n<li>Educational facilities (schools, universities)<\/li>\n<li>Healthcare facilities (hospitals, clinics)<\/li>\n<li>Transportation hubs (airports, train stations)<\/li>\n<li>Government and municipal buildings<\/li>\n<\/ul>\n<h3>Energy &amp; Utilities<\/h3>\n<ul>\n<li>Solar PV system protection circuits<\/li>\n<li>Wind turbine electrical systems<\/li>\n<li>Power generation auxiliary equipment<\/li>\n<li>Electrical substations and switchgear<\/li>\n<li>Energy storage system protection<\/li>\n<\/ul>\n<h3>OEM &amp; Panel Builders<\/h3>\n<ul>\n<li>Electrical panel manufacturers and switchgear assemblers<\/li>\n<li>Control system integrators<\/li>\n<li>Industrial equipment manufacturers<\/li>\n<li>Automation system providers<\/li>\n<li>Custom electrical solution designers<\/li>\n<\/ul>\n<hr \/>\n<h2>Dimensions &amp; Installation Data<\/h2>\n<p><strong>Modular Width (Standard 18mm Module):<\/strong><\/p>\n<ul>\n<li>1P: 1 module (17.8mm)<\/li>\n<li>2P: 2 modules (35.6mm)<\/li>\n<li>3P: 3 modules (53.4mm)<\/li>\n<li>4P: 4 modules (71.2mm)<\/li>\n<\/ul>\n<p><strong>Physical Dimensions:<\/strong><\/p>\n<ul>\n<li>Height: 83mm<\/li>\n<li>Depth: 74mm (1P), 63.5mm (multi-pole)<\/li>\n<li>DIN rail depth: 35mm<\/li>\n<\/ul>\n<p><strong>Installation:<\/strong><\/p>\n<ul>\n<li>Mounting: Standard 35mm DIN rail per IEC\/EN 60715<\/li>\n<li>Terminal type: Screw terminals (torque-controlled)<\/li>\n<li>Wire capacity: 1-25mm\u00b2 (both stranded and solid conductors)<\/li>\n<li>Connection: Top and bottom terminals for daisy-chain wiring<\/li>\n<\/ul>\n<figure><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-20338\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/VOB4-63-Dimension.webp\" alt=\"VOB4-63 Dimension\" width=\"1000\" height=\"427\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/VOB4-63-Dimension.webp 1000w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/VOB4-63-Dimension-300x128.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/VOB4-63-Dimension-768x328.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/VOB4-63-Dimension-18x8.webp 18w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/VOB4-63-Dimension-600x256.webp 600w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><figcaption><em>Figure 2: VOB4-63 precise dimensional drawings for panel layout and DIN-rail mounting<\/em><\/figcaption><\/figure>\n<hr \/>\n<h2>Certifications &amp; Quality Standards<\/h2>\n<h3>International Standards Compliance<\/h3>\n<p>\u2713 <strong>IEC 60898-1:<\/strong> Household and similar installations (residential, light commercial)<br \/>\n\u2713 <strong>IEC 60947-2:<\/strong> Industrial low-voltage switchgear and controlgear<br \/>\n\u2713 <strong>EN 60898-1:<\/strong> European standard for MCB performance<br \/>\n\u2713 <strong>Pollution Degree 2:<\/strong> Suitable for standard industrial environments<\/p>\n<h3>Manufacturing Quality<\/h3>\n<p>\u2713 <strong>ISO 9001:2015 Certified:<\/strong> Quality management system certified<br \/>\n\u2713 <strong>EU RoHS Compliant:<\/strong> Lead-free, environmentally responsible manufacturing<br \/>\n\u2713 <strong>Factory Testing:<\/strong> 100% electrical testing before shipment<br \/>\n\u2713 <strong>Traceability:<\/strong> Full batch tracking and quality documentation<\/p>\n<h3>Third-Party Verification<\/h3>\n<p>\u2713 Independent laboratory testing for breaking capacity verification<br \/>\n\u2713 Type testing per IEC standards<br \/>\n\u2713 Continuous production monitoring<\/p>\n<hr \/>\n<h2>VOB4-63 vs VOB3-63: Which MCB Should You Choose?<\/h2>\n<table border=\"1\" cellspacing=\"0\" cellpadding=\"5\">\n<thead>\n<tr>\n<th>Feature<\/th>\n<th>VOB3-63<\/th>\n<th>VOB4-63<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>Breaking Capacity<\/strong><\/td>\n<td>4.5kA \/ 6kA<\/td>\n<td><strong>6kA \/ 10kA<\/strong> \u2713<\/td>\n<\/tr>\n<tr>\n<td><strong>Insulation Voltage<\/strong><\/td>\n<td>415V~<\/td>\n<td><strong>500V~<\/strong> \u2713<\/td>\n<\/tr>\n<tr>\n<td><strong>Standards<\/strong><\/td>\n<td>IEC 60898-1<\/td>\n<td><strong>IEC 60898-1 &amp; 60947-2<\/strong> \u2713<\/td>\n<\/tr>\n<tr>\n<td><strong>Recommended Use<\/strong><\/td>\n<td>Residential, Light Commercial<\/td>\n<td><strong>Industrial, Heavy Commercial<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>Price Point<\/strong><\/td>\n<td>Economy<\/td>\n<td>Premium<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Choose VOB4-63 when:<\/strong><\/p>\n<ul>\n<li>Working in industrial environments with higher fault currents<\/li>\n<li>Protecting high-value equipment requiring maximum safety margin<\/li>\n<li>Compliance with IEC 60947-2 is required<\/li>\n<li>Long-term reliability in demanding conditions is critical<\/li>\n<\/ul>\n<hr \/>\n<h2>Why VIOX Electric for Your MCB Supply?<\/h2>\n<h3>Direct Manufacturer Advantages<\/h3>\n<ul>\n<li>Factory-direct pricing without middleman markup<\/li>\n<li>Consistent quality control throughout production<\/li>\n<li>Flexible MOQ for both small orders and bulk projects<\/li>\n<li>Custom labeling and OEM partnership available<\/li>\n<\/ul>\n<h3>Technical Support<\/h3>\n<ul>\n<li>Pre-sales engineering consultation<\/li>\n<li>Application-specific recommendations<\/li>\n<li>Technical documentation in multiple languages<\/li>\n<li>After-sales technical support<\/li>\n<\/ul>\n<h3>Global Supply Capability<\/h3>\n<ul>\n<li>ISO 9001:2015 certified manufacturing facility<\/li>\n<li>Capacity for large-volume orders<\/li>\n<li>Reliable delivery schedules<\/li>\n<li>International shipping experience<\/li>\n<\/ul>\n<h3>Product Range<\/h3>\n<ul>\n<li>Complete MCB ratings from 1A to 63A<\/li>\n<li>All pole configurations (1P, 2P, 3P, 4P)<\/li>\n<li>All trip curves (B, C, D)<\/li>\n<li>Both breaking capacities (6kA, 10kA)<\/li>\n<\/ul>\n<hr \/>\n<h2>How to Order VOB4-63 MCB<\/h2>\n<p><strong>Model Numbering System:<\/strong> VOB4-63 [Breaking Capacity] [Poles] [Curve] [Rating]<\/p>\n<p><strong>Examples:<\/strong><\/p>\n<ul>\n<li><strong>VOB4-63 10kA 3P C 32A<\/strong> &#8211; 10kA, 3-Pole, Type C curve, 32A rated current<\/li>\n<li><strong>VOB4-63 6kA 2P C 16A<\/strong> &#8211; 6kA, 2-Pole, Type C curve, 16A rated current<\/li>\n<li><strong>VOB4-63 10kA 4P D 63A<\/strong> &#8211; 10kA, 4-Pole, Type D curve, 63A rated current<\/li>\n<\/ul>\n<p><strong>Ordering Information Checklist:<\/strong><\/p>\n<ol>\n<li>Breaking capacity required (6kA or 10kA)<\/li>\n<li>Number of poles (1P, 2P, 3P, 4P)<\/li>\n<li>Trip curve type (B, C, or D)<\/li>\n<li>Rated current (1A to 63A)<\/li>\n<li>Quantity required<\/li>\n<li>Delivery timeline<\/li>\n<\/ol>\n<hr \/>\n<h2>Get Your Quote Today<\/h2>\n<h3>Contact VIOX Electric &#8211; MCB Manufacturer<\/h3>\n<p><strong>For Distributors &amp; Volume Orders:<\/strong><\/p>\n<ul>\n<li>Competitive volume pricing tiers<\/li>\n<li>Distributor partnership programs<\/li>\n<li>Co-branding and private labeling options<\/li>\n<li>Technical training and support<\/li>\n<\/ul>\n<p><strong>For Panel Builders &amp; OEM:<\/strong><\/p>\n<ul>\n<li>Engineering sample requests<\/li>\n<li>Custom specifications available<\/li>\n<li>CAD drawings and technical documentation<\/li>\n<li>Integration support<\/li>\n<\/ul>\n<p><strong>For Electrical Contractors:<\/strong><\/p>\n<ul>\n<li>Project-specific quotations<\/li>\n<li>Mixed order flexibility<\/li>\n<li>Fast delivery for urgent projects<\/li>\n<li>Technical application support<\/li>\n<\/ul>\n<h2>Frequently Asked Questions (FAQ)<\/h2>\n<p><strong>Q: What&#8217;s the difference between 6kA and 10kA breaking capacity?<\/strong><br \/>\nA: The breaking capacity indicates the maximum short-circuit current the MCB can safely interrupt. 10kA provides 67% more protection than 6kA, making it essential for industrial installations with higher fault current levels.<\/p>\n<p><strong>Q: Can VOB4-63 replace my existing MCB?<\/strong><br \/>\nA: Yes, VOB4-63 is DIN-rail compatible and follows standard modular sizing. Ensure the breaking capacity, voltage rating, and pole configuration match your application requirements.<\/p>\n<p><strong>Q: What&#8217;s the lead time for bulk orders?<\/strong><br \/>\nA: Standard lead time is 2-4 weeks depending on order quantity and specifications. Contact our sales team for urgent orders.<\/p>\n<p><strong>Q: Do you provide technical documentation?<\/strong><br \/>\nA: Yes, complete technical datasheets, CAD drawings, installation manuals, and certificates are provided with every order.<\/p>\n<p><strong>Q: What&#8217;s your MOQ (Minimum Order Quantity)?<\/strong><br \/>\nA: We accommodate both small sample orders and large-volume projects. Contact us for specific MOQ based on your requirements.<\/p>\n<hr \/>\n<h2>Related VIOX Circuit Protection Products<\/h2>\n<ul>\n<li><strong>MCCB Series (Molded Case Circuit Breakers):<\/strong> For higher ratings up to 1600A and breaking capacities up to 100kA<\/li>\n<li><strong>RCCB\/RCBO:<\/strong> Add earth leakage protection with residual current devices<\/li>\n<li><strong>ACB Series (Air Circuit Breakers):<\/strong> Main distribution circuit breakers for large facilities<\/li>\n<li><strong>Load Break Switches:<\/strong> Manual isolation and switching up to 125A<\/li>\n<li><strong>SPD (Surge Protection Devices):<\/strong> Lightning and surge protection<\/li>\n<\/ul>\n<p><a href=\"https:\/\/test.viox.com\/mcb\"><strong>[VIEW ALL CIRCUIT PROTECTION PRODUCTS \u2192]<\/strong><\/a><\/p>\n<hr \/>\n<h2>Download Resources<\/h2>\n<ul>\n<li>\ud83d\udcc4 <strong>VOB4-63 Technical Datasheet<\/strong> (PDF)<\/li>\n<li>\ud83d\udcc4 <strong>Installation &amp; Wiring Guide<\/strong> (PDF)<\/li>\n<li>\ud83d\udcc4 <strong>IEC 60898-1 &amp; 60947-2 Compliance Certificate<\/strong><\/li>\n<li>\ud83d\udcc4 <strong>CAD Drawings (DWG\/DXF)<\/strong><\/li>\n<li>\ud83d\udcd8 <strong>Complete VIOX MCB Product Catalog<\/strong><\/li>\n<\/ul>\n<p><a href=\"https:\/\/test.viox.com\/contact\"><strong>[DOWNLOAD ALL RESOURCES]<\/strong><\/a><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<\/div>\n<div class=\"simg-pop-btn\" style=\"top: 4910.21px; left: 24px; display: none;\"><\/div>\n<div class=\"simg-pop-btn\" style=\"top: 4910.21px; left: 24px; display: none;\"><\/div>\n","protected":false},"excerpt":{"rendered":"<ul>\n<li><strong>Double Pouvoir de Coupure :<\/strong> 6000A ou 10000A \u2013 protection sup\u00e9rieure contre les d\u00e9fauts pour les syst\u00e8mes industriels<\/li>\n<li><strong>Isolation Am\u00e9lior\u00e9e :<\/strong> Tension d'isolation nominale AC 500V (sup\u00e9rieure \u00e0 la norme 415V)<\/li>\n<li><strong>Double Conformit\u00e9 aux Normes :<\/strong> Certifi\u00e9 IEC 60898-1 &amp; IEC 60947-2 pour les applications r\u00e9sidentielles et industrielles<\/li>\n<li><strong>Gamme Compl\u00e8te de Calibres :<\/strong> 1A \u00e0 63A par incr\u00e9ments complets (1A, 2A, 3A, 4A, 5A, 6A, 8A, 10A, 13A, 16A, 20A, 25A, 32A, 40A, 50A, 63A)<\/li>\n<li><strong>Toutes les Courbes de D\u00e9clenchement Disponibles :<\/strong> Courbes de type B, C, D pour toute exigence d'application<\/li>\n<li><strong>Durabilit\u00e9 industrielle :<\/strong> 10 000 op\u00e9rations m\u00e9caniques, 4 000 cycles \u00e9lectriques<\/li>\n<li><strong>Installation professionnelle :<\/strong> Montage sur rail DIN, capacit\u00e9 de raccordement 1-25mm\u00b2<\/li>\n<li><strong>Qualit\u00e9 Prouv\u00e9e :<\/strong> Fabriqu\u00e9 par VIOX Electric certifi\u00e9 ISO 9001:2015<\/li>\n<\/ul>","protected":false},"featured_media":20337,"comment_status":"closed","ping_status":"closed","template":"","meta":{"inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[],"product_cat":[130,116],"product_tag":[],"class_list":{"0":"post-20336","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-mcb","7":"product_cat-low-voltage-protection-devices","8":"desktop-align-left","9":"tablet-align-left","10":"mobile-align-left","12":"first","13":"instock","14":"shipping-taxable","15":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/test.viox.com\/fr\/wp-json\/wp\/v2\/product\/20336","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/test.viox.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/test.viox.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/test.viox.com\/fr\/wp-json\/wp\/v2\/comments?post=20336"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/test.viox.com\/fr\/wp-json\/wp\/v2\/media\/20337"}],"wp:attachment":[{"href":"https:\/\/test.viox.com\/fr\/wp-json\/wp\/v2\/media?parent=20336"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/test.viox.com\/fr\/wp-json\/wp\/v2\/product_brand?post=20336"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/test.viox.com\/fr\/wp-json\/wp\/v2\/product_cat?post=20336"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/test.viox.com\/fr\/wp-json\/wp\/v2\/product_tag?post=20336"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}