{"id":20874,"date":"2025-12-16T01:52:08","date_gmt":"2025-12-15T17:52:08","guid":{"rendered":"https:\/\/viox.com\/?p=20874"},"modified":"2025-12-16T01:55:18","modified_gmt":"2025-12-15T17:55:18","slug":"terminal-block-selection-guide-types-uses","status":"publish","type":"post","link":"https:\/\/test.viox.com\/fr\/terminal-block-selection-guide-types-uses\/","title":{"rendered":"Le guide ultime des borniers : types, utilisations et fonctions"},"content":{"rendered":"<div class=\"product-intro\">\n<p>La sp\u00e9cification des borniers pour un panneau industriel devrait \u00eatre simple. Mais lorsque les e-mails d'approvisionnement demandent s'il faut utiliser des bornes \u00e0 vis ou \u00e0 ressort, ou lorsque les sp\u00e9cifications \u00e9num\u00e8rent des \u201cblocs de barri\u00e8re\u201d sans contexte, la clart\u00e9 devient essentielle. Les ing\u00e9nieurs \u00e9lectriciens ont besoin de crit\u00e8res de s\u00e9lection pr\u00e9cis. Les entrepreneurs ont besoin de l'assurance qu'ils commandent le bon mat\u00e9riel. Les gestionnaires d'installations veulent des terminaisons qui restent s\u00e9curis\u00e9es pendant des ann\u00e9es de vibrations et de cycles de temp\u00e9rature.<\/p>\n<p>Les borniers - dispositifs modulaires isol\u00e9s qui connectent m\u00e9caniquement et \u00e9lectriquement les conducteurs - forment l'\u00e9pine dorsale du c\u00e2blage organis\u00e9 dans les panneaux de commande, les machines et l'automatisation des b\u00e2timents. Mont\u00e9s sur rail DIN \u00e0 l'int\u00e9rieur des bo\u00eetiers, ils transforment le c\u00e2blage point \u00e0 point chaotique en circuits structur\u00e9s et \u00e9tiquet\u00e9s.<\/p>\n<p>Ce guide \u00e9tablit une taxonomie claire des types de borniers, fournit des tableaux comparatifs pour la sp\u00e9cification et fournit des conseils de s\u00e9lection pratiques align\u00e9s sur les normes IEC 60947-7-1 et UL 1059.<\/p>\n<h2>Qu'est-ce qu'une <a href=\"https:\/\/test.viox.com\/fr\/terminal-block\/\">Bornier<\/a>?<\/h2>\n<p>Un bornier est un bo\u00eetier modulaire isol\u00e9 contenant :<\/p>\n<ul>\n<li><strong>\u00c9l\u00e9ment conducteur<\/strong>: Contact m\u00e9tallique (g\u00e9n\u00e9ralement en cuivre ou en laiton) qui transporte le courant entre les conducteurs<\/li>\n<li><strong>M\u00e9canisme de serrage<\/strong>: Vis, ressort ou dispositif enfichable qui fixe les extr\u00e9mit\u00e9s d\u00e9nud\u00e9es des fils<\/li>\n<li><strong>Corps isolant<\/strong>: Plastique ignifuge (polyamide, polycarbonate) assurant l'isolation \u00e9lectrique et la protection m\u00e9canique<\/li>\n<li><strong>Syst\u00e8me de montage<\/strong>: Clip de rail DIN (EN 60715) ou trous de vis de panneau pour une installation s\u00e9curis\u00e9e<\/li>\n<\/ul>\n<h3>Respect des normes<\/h3>\n<p>Les borniers pour les applications industrielles, commerciales et r\u00e9sidentielles sont conformes \u00e0 :<\/p>\n<ul>\n<li><strong>IEC 60947-7-1:2025<\/strong> (\u00c9dition 4.0) : Borniers pour appareillage basse tension et appareillage de commande pour conducteurs en cuivre ; couvre les caract\u00e9ristiques \u00e9lectriques, les m\u00e9thodes d'essai, les tailles de conducteurs et les exigences m\u00e9caniques<\/li>\n<li><strong>UL 1059<\/strong>: Borniers pour les march\u00e9s nord-am\u00e9ricains ; d\u00e9finit la construction, l'espacement, l'\u00e9l\u00e9vation de temp\u00e9rature et les essais de court-circuit<\/li>\n<li><strong>EN 60715<\/strong>: Normes de profil\u00e9s de montage sur rail DIN assurant la compatibilit\u00e9 m\u00e9canique entre les fabricants<\/li>\n<\/ul>\n<p>Les borniers fonctionnent dans des circuits jusqu'\u00e0 <strong>1000V AC (\u22641000Hz)<\/strong> ou <strong>1500V DC<\/strong>, supportant des tailles de conducteurs de <strong>0.2mm\u00b2 \u00e0 300mm\u00b2<\/strong> (AWG 24 \u00e0 600 kcmil), avec des courants nominaux allant de <strong>6A \u00e0 400A<\/strong>.<\/p>\n<figure style=\"text-align: center; margin: 20px 0;\"><img decoding=\"async\" style=\"max-width: 100%; height: auto;\" src=\"https:\/\/img.viox.com\/professional-industrial-photography-showing-viox-terminal-blocks-mounted-on-din-rail-inside-electrical-control-panel.webp\" alt=\"Professional industrial photography showing VIOX terminal blocks mounted on DIN rail inside electrical control panel\" \/><figcaption style=\"color: #666; font-size: 0.9em; margin-top: 5px;\">Photographie industrielle professionnelle montrant des borniers VIOX mont\u00e9s sur <a href=\"https:\/\/test.viox.com\/fr\/din-rail\/\">Rail DIN<\/a> \u00e0 l'int\u00e9rieur d'un panneau de commande \u00e9lectrique.<\/figcaption><\/figure>\n<h2>Types de borniers : Par m\u00e9thode de serrage<\/h2>\n<h3>Blocs de bornes \u00e0 vis<\/h3>\n<p><strong>La construction<\/strong>: Une vis filet\u00e9e comprime le conducteur contre un contact. Le couple de serrage cr\u00e9e une continuit\u00e9 \u00e9lectrique.<\/p>\n<p><strong>Avantages<\/strong>:<\/p>\n<ul>\n<li>Large gamme de conducteurs dans un seul appareil (par exemple, 0,5 mm\u00b2 \u00e0 6 mm\u00b2)<\/li>\n<li>Grande robustesse m\u00e9canique adapt\u00e9e aux applications \u00e0 courant \u00e9lev\u00e9 (jusqu'\u00e0 150A+)<\/li>\n<li>M\u00e9thode d'installation famili\u00e8re ; universellement accept\u00e9e<\/li>\n<li>Co\u00fbt par position inf\u00e9rieur \u00e0 celui des technologies \u00e0 ressort<\/li>\n<\/ul>\n<p><strong>Consid\u00e9rations<\/strong>:<\/p>\n<ul>\n<li>L'installation n\u00e9cessite des tournevis dynamom\u00e9triques calibr\u00e9s (typique : 0,5-2,5 N\u00b7m selon la taille)<\/li>\n<li>Les vibrations ou les cycles thermiques peuvent desserrer les connexions ; un resserrage p\u00e9riodique est recommand\u00e9<\/li>\n<li>Temps d'installation plus long que les alternatives \u00e0 ressort<\/li>\n<li>La comp\u00e9tence de l'installateur affecte la qualit\u00e9 de la connexion<\/li>\n<\/ul>\n<p><strong>Les Applications Typiques<\/strong>: C\u00e2blage de b\u00e2timents, panneaux de distribution d'\u00e9nergie, circuits de commande de machines, installations de r\u00e9novation<\/p>\n<h3>Borniers \u00e0 ressort<\/h3>\n<p><strong>La construction<\/strong>: Un \u00e9l\u00e9ment de ressort pr\u00e9charg\u00e9 exerce une force de serrage constante. Un tournevis ou un bouton-poussoir lib\u00e8re le ressort pour l'insertion\/le retrait du fil.<\/p>\n<p><strong>Avantages<\/strong>:<\/p>\n<ul>\n<li>Installation plus rapide - aucune sp\u00e9cification de couple requise<\/li>\n<li>Maintient une pression constante ind\u00e9pendamment des vibrations ou des changements de temp\u00e9rature<\/li>\n<li>Exigences de formation r\u00e9duites pour l'installateur<\/li>\n<li>Excellentes performances dans les environnements \u00e0 fortes vibrations (moteurs, v\u00e9hicules ferroviaires, machines lourdes)<\/li>\n<li>Maintenance r\u00e9duite - pas de resserrage p\u00e9riodique<\/li>\n<\/ul>\n<p><strong>Consid\u00e9rations<\/strong>:<\/p>\n<ul>\n<li>Co\u00fbt par position plus \u00e9lev\u00e9 que les bornes \u00e0 vis<\/li>\n<li>Pr\u00e9paration des fils critique (longueur de d\u00e9nudage, utilisation de l'embout)<\/li>\n<li>L'\u00e9l\u00e9ment de ressort peut se fatiguer apr\u00e8s de nombreux cycles d'insertion (g\u00e9n\u00e9ralement \u00e9valu\u00e9 \u00e0 &gt;20 cycles)<\/li>\n<\/ul>\n<p><strong>Les Applications Typiques<\/strong>: Automatisation industrielle, armoires de commande soumises \u00e0 des vibrations, installations n\u00e9cessitant des changements de circuits fr\u00e9quents, syst\u00e8mes d'\u00e9nergie renouvelable<\/p>\n<h3>Blocs terminaux Push-In<\/h3>\n<p><strong>La construction<\/strong>: Insertion sans outil d'un conducteur \u00e0 embout ou solide dans un contact \u00e0 cage \u00e0 ressort. Lib\u00e9ration par bouton-poussoir ou fente de tournevis.<\/p>\n<p><strong>Avantages<\/strong>:<\/p>\n<ul>\n<li><strong>M\u00e9thode d'installation la plus rapide<\/strong>\u2014aucun outil requis pour la connexion<\/li>\n<li>Conception ultra-compacte maximisant la densit\u00e9 du panneau<\/li>\n<li>Id\u00e9al pour les changements de c\u00e2blage \u00e0 haute fr\u00e9quence<\/li>\n<li>Excellent dans les environnements difficiles (marins, chimiques, ext\u00e9rieurs)<\/li>\n<li>Erreurs de c\u00e2blage r\u00e9duites gr\u00e2ce \u00e0 une insertion simple<\/li>\n<\/ul>\n<p><strong>Consid\u00e9rations<\/strong>:<\/p>\n<ul>\n<li>N\u00e9cessite des embouts sur les conducteurs toronn\u00e9s pour un contact fiable<\/li>\n<li>Ne convient pas aux fils tr\u00e8s fins (g\u00e9n\u00e9ralement \u22650,5 mm\u00b2)<\/li>\n<li>Limit\u00e9 aux courants nominaux inf\u00e9rieurs (g\u00e9n\u00e9ralement \u226432A)<\/li>\n<\/ul>\n<p><strong>Les Applications Typiques<\/strong>: Panneaux de commande haute densit\u00e9, c\u00e2blage d'E\/S, automatisation distribu\u00e9e, construction de machines modulaires<\/p>\n<h3>Tableau comparatif : M\u00e9thodes de serrage<\/h3>\n<table style=\"border-collapse: collapse; width: 100%; text-align: left;\" border=\"1\">\n<thead>\n<tr style=\"background-color: #f2f2f2;\">\n<th style=\"padding: 8px;\">Fonctionnalit\u00e9<\/th>\n<th style=\"padding: 8px;\">Borne \u00e0 vis<\/th>\n<th style=\"padding: 8px;\">Borne \u00e0 ressort<\/th>\n<th style=\"padding: 8px;\">Borne enfichable<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"padding: 8px;\"><strong>Vitesse d'installation<\/strong><\/td>\n<td style=\"padding: 8px;\">Mod\u00e9r\u00e9 (couple requis)<\/td>\n<td style=\"padding: 8px;\">Rapide (pas de couple)<\/td>\n<td style=\"padding: 8px;\">Tr\u00e8s rapide (sans outil)<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px;\"><strong>Comp\u00e9tence requise<\/strong><\/td>\n<td style=\"padding: 8px;\">Mod\u00e9r\u00e9 (contr\u00f4le du couple)<\/td>\n<td style=\"padding: 8px;\">Faible<\/td>\n<td style=\"padding: 8px;\">Tr\u00e8s faible<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px;\"><strong>R\u00e9sistance aux vibrations<\/strong><\/td>\n<td style=\"padding: 8px;\">Mod\u00e9r\u00e9 (peut se desserrer)<\/td>\n<td style=\"padding: 8px;\">Excellent (pression constante)<\/td>\n<td style=\"padding: 8px;\">Excellent<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px;\"><strong>Maintenance<\/strong><\/td>\n<td style=\"padding: 8px;\">Resserrage p\u00e9riodique<\/td>\n<td style=\"padding: 8px;\">Minime<\/td>\n<td style=\"padding: 8px;\">Minime<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px;\"><strong>Note Actuelle<\/strong><\/td>\n<td style=\"padding: 8px;\">6A \u2013 400A<\/td>\n<td style=\"padding: 8px;\">6A \u2013 125A<\/td>\n<td style=\"padding: 8px;\">6A \u2013 32A<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px;\"><strong>Co\u00fbt par position<\/strong><\/td>\n<td style=\"padding: 8px;\">Faible<\/td>\n<td style=\"padding: 8px;\">Moyen-\u00c9lev\u00e9<\/td>\n<td style=\"padding: 8px;\">Moyen-\u00c9lev\u00e9<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px;\"><strong>Plage de c\u00e2bles typique<\/strong><\/td>\n<td style=\"padding: 8px;\">0,5 mm\u00b2 \u2013 95 mm\u00b2<\/td>\n<td style=\"padding: 8px;\">0,08 mm\u00b2 \u2013 35 mm\u00b2<\/td>\n<td style=\"padding: 8px;\">0,5 mm\u00b2 \u2013 4 mm\u00b2<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px;\"><strong>Meilleure application<\/strong><\/td>\n<td style=\"padding: 8px;\">Distribution d'\u00e9nergie, haute puissance<\/td>\n<td style=\"padding: 8px;\">Vibrations, changements fr\u00e9quents<\/td>\n<td style=\"padding: 8px;\">Haute densit\u00e9, installation rapide<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<figure style=\"text-align: center; margin: 20px 0;\"><img decoding=\"async\" style=\"max-width: 100%; height: auto;\" src=\"https:\/\/img.viox.com\/technical-cutaway-cross-section-diagram-showing-internal-construction-of-three-terminal-block-clamping-methods.webp\" alt=\"Technical cutaway cross-section diagram showing internal construction of three terminal block clamping methods\" \/><figcaption style=\"color: #666; font-size: 0.9em; margin-top: 5px;\">Sch\u00e9ma technique en coupe transversale montrant la construction interne des borniers \u00e0 vis, \u00e0 ressort et \u00e0 insertion.<\/figcaption><\/figure>\n<h2>Types de borniers\u00a0: par fonction et configuration<\/h2>\n<p>Au-del\u00e0 de la m\u00e9thode de serrage, les borniers sont class\u00e9s par fonction de circuit, style de montage et caract\u00e9ristiques sp\u00e9ciales.<\/p>\n<h3>Borniers traversants<\/h3>\n<p><strong>Fonction<\/strong>\u00a0: Fournissent une connexion fil \u00e0 fil avec des points d'entr\u00e9e sur les c\u00f4t\u00e9s oppos\u00e9s du bornier. Pas de cavaliers internes ni de commutation\u00a0: pur passage.<\/p>\n<p><strong>Cas d&#039;utilisation<\/strong>\u00a0: C\u00e2blage de distribution g\u00e9n\u00e9rale, extensions de circuit, interconnexions de panneaux<\/p>\n<p><strong>Sp\u00e9cifications<\/strong>\u00a0: Disponible dans tous les types de serrage\u00a0; courants nominaux 6A-150A\u00a0; configurations \u00e0 un ou plusieurs niveaux<\/p>\n<h3>Borniers de terre<\/h3>\n<p><strong>Fonction<\/strong>\u00a0: Connectent les conducteurs de terre de protection (PE) au rail DIN ou \u00e0 la barre omnibus de terre d\u00e9di\u00e9e. Comportent souvent une isolation verte\/jaune et un contact m\u00e9tallique direct avec le rail.<\/p>\n<p><strong>Cas d&#039;utilisation<\/strong>\u00a0: Chaque panneau de commande ou tableau de distribution n\u00e9cessite des terminaisons de terre d\u00e9di\u00e9es<\/p>\n<h3>Borniers de sectionnement (test)<\/h3>\n<p><strong>Fonction<\/strong>\u00a0: Incluent un cavalier amovible, une liaison ou un interrupteur \u00e0 couteau qui interrompt le circuit pour les tests ou l'isolation sans retirer les fils.<\/p>\n<p><strong>Cas d&#039;utilisation<\/strong>\u00a0: Points de mesure de courant, circuits d'\u00e9talonnage de capteurs, acc\u00e8s de mise en service<\/p>\n<h3>Borniers \u00e0 fusible<\/h3>\n<p><strong>Fonction<\/strong>\u00a0: Int\u00e8grent un porte-fusible et des contacts dans un seul module de rail DIN, offrant une protection contre les surintensit\u00e9s au point de terminaison.<\/p>\n<p><strong>Avantages<\/strong>\u00a0: \u00c9limine les porte-fusibles s\u00e9par\u00e9s, r\u00e9duit le c\u00e2blage, simplifie le d\u00e9pannage (fusible grill\u00e9 visible)<\/p>\n<p><strong>Types de fusibles<\/strong>\u00a0: Accepte les fusibles cylindriques 5x20mm, 6,3x32mm ou 10x38mm\u00a0; certains mod\u00e8les incluent des indicateurs de fusible grill\u00e9<\/p>\n<p><strong>Cas d&#039;utilisation<\/strong>\u00a0: Protection des circuits de d\u00e9rivation, protection d'entr\u00e9e de l'\u00e9quipement, isolation de charge individuelle<\/p>\n<h3>Blocs terminaux multi-niveaux<\/h3>\n<p><strong>Fonction<\/strong>\u00a0: Empilez deux ou trois circuits ind\u00e9pendants dans un seul encombrement de module (empilement vertical). Chaque niveau est isol\u00e9 \u00e9lectriquement.<\/p>\n<p><strong>Avantages<\/strong>\u00a0: \u00c9conomise de l'espace sur le rail DIN (am\u00e9lioration de la densit\u00e9 de 2x \u00e0 3x), organise les signaux associ\u00e9s (par exemple, 0V, +24V, signal)<\/p>\n<p><strong>Cas d&#039;utilisation<\/strong>\u00a0: Panneaux haute densit\u00e9, bo\u00eetiers compacts, distribution de signaux + alimentation dans les armoires d'automatisation<\/p>\n<h3>Borniers \u00e0 barri\u00e8re (bandes de barri\u00e8re)<\/h3>\n<p><strong>Fonction<\/strong>\u00a0: Barrette de connexion \u00e0 une seule rang\u00e9e avec des barri\u00e8res d'isolation sur\u00e9lev\u00e9es entre chaque position, emp\u00eachant tout contact accidentel entre les circuits adjacents.<\/p>\n<p><strong>Montage<\/strong>\u00a0: G\u00e9n\u00e9ralement viss\u00e9 sur le panneau ou le bo\u00eetier (pas sur le rail DIN)<\/p>\n<p><strong>Cas d&#039;utilisation<\/strong>\u00a0: Circuits haute tension, connexions d'alimentation, environnements sujets aux vibrations, installations plus anciennes<\/p>\n<h3>Blocs de distribution d'\u00e9nergie<\/h3>\n<p><strong>Fonction<\/strong>\u00a0: Bornes robustes con\u00e7ues pour les alimentations principales ou les connexions de charge importantes. Plusieurs positions de sortie aliment\u00e9es \u00e0 partir d'une seule entr\u00e9e.<\/p>\n<p><strong>Sp\u00e9cifications<\/strong>\u00a0: Capacit\u00e9 de courant \u00e9lev\u00e9e (150A-600A), acceptation de conducteurs de grande taille (35mm\u00b2-300mm\u00b2), couvercles isol\u00e9s ou prot\u00e8ge-doigts<\/p>\n<p><strong>Cas d&#039;utilisation<\/strong>\u00a0: Connexions de barres omnibus principales, alimentations de moteurs, distribution triphas\u00e9e<\/p>\n<h3>Tableau comparatif des fonctions<\/h3>\n<table style=\"border-collapse: collapse; width: 100%; text-align: left;\" border=\"1\">\n<thead>\n<tr style=\"background-color: #f2f2f2;\">\n<th style=\"padding: 8px;\">Type de bornier<\/th>\n<th style=\"padding: 8px;\">Fonction principale<\/th>\n<th style=\"padding: 8px;\">Montage<\/th>\n<th style=\"padding: 8px;\">Plage de courant typique<\/th>\n<th style=\"padding: 8px;\">Caract\u00e9ristique principale<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"padding: 8px;\"><strong>Traversant<\/strong><\/td>\n<td style=\"padding: 8px;\">Passage fil \u00e0 fil<\/td>\n<td style=\"padding: 8px;\">Rail DIN<\/td>\n<td style=\"padding: 8px;\">6A \u2013 150A<\/td>\n<td style=\"padding: 8px;\">Distribution simple<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px;\"><strong>Terre (PE)<\/strong><\/td>\n<td style=\"padding: 8px;\">Connexion de terre de protection<\/td>\n<td style=\"padding: 8px;\">Rail DIN<\/td>\n<td style=\"padding: 8px;\">6A \u2013 150A<\/td>\n<td style=\"padding: 8px;\">Contact direct avec le rail, codage vert\/jaune<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px;\"><strong>Sectionnement (test)<\/strong><\/td>\n<td style=\"padding: 8px;\">Interruption de circuit sans d\u00e9connexion<\/td>\n<td style=\"padding: 8px;\">Rail DIN<\/td>\n<td style=\"padding: 8px;\">6A \u2013 125A<\/td>\n<td style=\"padding: 8px;\">Cavalier amovible ou interrupteur \u00e0 couteau<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px;\"><strong>Borne \u00e0 fusible<\/strong><\/td>\n<td style=\"padding: 8px;\">Protection int\u00e9gr\u00e9e contre les surintensit\u00e9s<\/td>\n<td style=\"padding: 8px;\">Rail DIN<\/td>\n<td style=\"padding: 8px;\">6A \u2013 32A<\/td>\n<td style=\"padding: 8px;\">Indicateur de fusible grill\u00e9, modulaire<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px;\"><strong>Multi-niveaux<\/strong><\/td>\n<td style=\"padding: 8px;\">Circuits empil\u00e9s (2-3 niveaux)<\/td>\n<td style=\"padding: 8px;\">Rail DIN<\/td>\n<td style=\"padding: 8px;\">6A \u2013 32A par niveau<\/td>\n<td style=\"padding: 8px;\">Signaux organis\u00e9s et peu encombrants<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px;\"><strong>Bornier \u00e0 barri\u00e8re<\/strong><\/td>\n<td style=\"padding: 8px;\">Positions isol\u00e9es \u00e0 une rang\u00e9e<\/td>\n<td style=\"padding: 8px;\">Montage par vis sur panneau<\/td>\n<td style=\"padding: 8px;\">15A \u2013 100A<\/td>\n<td style=\"padding: 8px;\">Barri\u00e8res sur\u00e9lev\u00e9es, isolation haute tension<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px;\"><strong>Distribution de l'\u00e9nergie<\/strong><\/td>\n<td style=\"padding: 8px;\">Alimentations principales \u00e0 courant \u00e9lev\u00e9<\/td>\n<td style=\"padding: 8px;\"><a href=\"https:\/\/test.viox.com\/fr\/busbar\/\">Jeu de barres<\/a> ou montage sur panneau<\/td>\n<td style=\"padding: 8px;\">150A \u2013 600A<\/td>\n<td style=\"padding: 8px;\">Conducteurs lourds, sorties multiples<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<figure style=\"text-align: center; margin: 20px 0;\"><img decoding=\"async\" style=\"max-width: 100%; height: auto;\" src=\"https:\/\/img.viox.com\/electrical-wiring-schematic-diagram-illustrating-terminal-block-connection-layout-on-din-rail.webp\" alt=\"Electrical wiring schematic diagram illustrating terminal block connection layout on DIN rail\" \/><figcaption style=\"color: #666; font-size: 0.9em; margin-top: 5px;\">Sch\u00e9ma de c\u00e2blage \u00e9lectrique illustrant la disposition de la connexion du bornier sur rail DIN.<\/figcaption><\/figure>\n<h2>Sp\u00e9cifications techniques et crit\u00e8res de s\u00e9lection<\/h2>\n<p>La sp\u00e9cification du bornier correct n\u00e9cessite de faire correspondre les exigences \u00e9lectriques, les contraintes m\u00e9caniques et l'environnement d'installation.<\/p>\n<p><strong>Courant nominal (In)<\/strong>: Courant continu maximal sans d\u00e9passer les limites d'\u00e9l\u00e9vation de temp\u00e9rature (g\u00e9n\u00e9ralement 50K au-dessus de la temp\u00e9rature ambiante).<\/p>\n<p><strong>Tension nominale (Ue)<\/strong>: Tension de fonctionnement maximale (AC ou DC). D\u00e9termine les distances de cheminement et de d\u00e9gagement.<\/p>\n<p><strong>Compatibilit\u00e9 de la taille des conducteurs<\/strong>:<\/p>\n<table style=\"border-collapse: collapse; width: 100%; text-align: left;\" border=\"1\">\n<thead>\n<tr style=\"background-color: #f2f2f2;\">\n<th style=\"padding: 8px;\">Courant nominal du bornier<\/th>\n<th style=\"padding: 8px;\">Fil massif (mm\u00b2)<\/th>\n<th style=\"padding: 8px;\">Fil toronn\u00e9 (mm\u00b2)<\/th>\n<th style=\"padding: 8px;\">Toronn\u00e9 + embout (mm\u00b2)<\/th>\n<th style=\"padding: 8px;\">\u00c9quivalent AWG<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"padding: 8px;\"><strong>6A \u2013 10A<\/strong><\/td>\n<td style=\"padding: 8px;\">0.2 \u2013 2.5<\/td>\n<td style=\"padding: 8px;\">0.2 \u2013 2.5<\/td>\n<td style=\"padding: 8px;\">0.25 \u2013 2.5<\/td>\n<td style=\"padding: 8px;\">24 \u2013 14<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px;\"><strong>17A \u2013 24A<\/strong><\/td>\n<td style=\"padding: 8px;\">0.5 \u2013 4.0<\/td>\n<td style=\"padding: 8px;\">0.5 \u2013 4.0<\/td>\n<td style=\"padding: 8px;\">0.5 \u2013 4.0<\/td>\n<td style=\"padding: 8px;\">20 \u2013 12<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px;\"><strong>32A \u2013 41A<\/strong><\/td>\n<td style=\"padding: 8px;\">1.0 \u2013 6.0<\/td>\n<td style=\"padding: 8px;\">1.0 \u2013 6.0<\/td>\n<td style=\"padding: 8px;\">1.5 \u2013 6.0<\/td>\n<td style=\"padding: 8px;\">16 \u2013 10<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px;\"><strong>57A \u2013 76A<\/strong><\/td>\n<td style=\"padding: 8px;\">2.5 \u2013 10<\/td>\n<td style=\"padding: 8px;\">2.5 \u2013 10<\/td>\n<td style=\"padding: 8px;\">4.0 \u2013 10<\/td>\n<td style=\"padding: 8px;\">12 \u2013 8<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px;\"><strong>101A \u2013 125A<\/strong><\/td>\n<td style=\"padding: 8px;\">10 \u2013 35<\/td>\n<td style=\"padding: 8px;\">10 \u2013 35<\/td>\n<td style=\"padding: 8px;\">16 \u2013 35<\/td>\n<td style=\"padding: 8px;\">8 \u2013 2<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px;\"><strong>150A+<\/strong><\/td>\n<td style=\"padding: 8px;\">25 \u2013 95+<\/td>\n<td style=\"padding: 8px;\">25 \u2013 95+<\/td>\n<td style=\"padding: 8px;\">35 \u2013 95+<\/td>\n<td style=\"padding: 8px;\">2 \u2013 4\/0+<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><em>Remarque : Valeurs nominales selon IEC 60947-7-1 ; la capacit\u00e9 r\u00e9elle d\u00e9pend du mat\u00e9riau du conducteur, de la temp\u00e9rature ambiante et de la configuration de l'installation.<\/em><\/p>\n<p><strong>Pas du bornier<\/strong>: Espacement centre \u00e0 centre entre les bornes adjacentes : 2,54 mm (signaux ultra-compacts), 5,0 mm\/5,08 mm (contr\u00f4le standard), 7,5 mm (service moyen), 10 mm\/12 mm (service intensif), 15 mm+ (haute puissance)<\/p>\n<p><strong>Nombre de p\u00f4les<\/strong>: Combien de circuits ind\u00e9pendants existent dans un bo\u00eetier de bornier<\/p>\n<ul>\n<li>Unipolaire (1P) : Un circuit par bloc<\/li>\n<li>Multipolaire (2P, 3P, 4P) : Plusieurs circuits partagent un bo\u00eetier commun (courant dans la distribution d'\u00e9nergie)<\/li>\n<\/ul>\n<p><strong>Compatibilit\u00e9 rail DIN<\/strong>: Standard 35 mm \u00d7 7,5 mm ou 35 mm \u00d7 15 mm (EN 60715)<\/p>\n<h3>Facteurs environnementaux et d'installation<\/h3>\n<table style=\"border-collapse: collapse; width: 100%; text-align: left;\" border=\"1\">\n<thead>\n<tr style=\"background-color: #f2f2f2;\">\n<th style=\"padding: 8px;\">Facteur de S\u00e9lection<\/th>\n<th style=\"padding: 8px;\">Consid\u00e9rations<\/th>\n<th style=\"padding: 8px;\">Recommandation<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"padding: 8px;\"><strong>Environnement de vibration<\/strong><\/td>\n<td style=\"padding: 8px;\">Moteurs, v\u00e9hicules ferroviaires, machines lourdes<\/td>\n<td style=\"padding: 8px;\">\u00c0 ressort ou enfichable ; \u00e9viter les vis sauf si le couple est v\u00e9rifi\u00e9<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px;\"><strong>Plage De Temp\u00e9rature<\/strong><\/td>\n<td style=\"padding: 8px;\">Ext\u00e9rieur, compartiments moteur, fours<\/td>\n<td style=\"padding: 8px;\">V\u00e9rifier la temp\u00e9rature nominale du bornier (g\u00e9n\u00e9ralement de -40\u00b0C \u00e0 +105\u00b0C)<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px;\"><strong>Exposition aux produits chimiques<\/strong><\/td>\n<td style=\"padding: 8px;\">Marine, usines chimiques, traitement des eaux us\u00e9es<\/td>\n<td style=\"padding: 8px;\">Contacts en acier inoxydable, polym\u00e8res sp\u00e9ciaux (par exemple, PA66-GF)<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px;\"><strong>D\u00e9connexion fr\u00e9quente<\/strong><\/td>\n<td style=\"padding: 8px;\">\u00c9quipement de test, machines modulaires, installations temporaires<\/td>\n<td style=\"padding: 8px;\">\u00c0 ressort ou enfichable (cycles d'insertion &gt; 20)<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px;\"><strong>Densit\u00e9 de conducteur \u00e9lev\u00e9e<\/strong><\/td>\n<td style=\"padding: 8px;\">Bo\u00eetiers compacts, \u00e9quipements mobiles, E\/S distribu\u00e9es<\/td>\n<td style=\"padding: 8px;\">Bornes \u00e0 insertion, blocs multi-niveaux<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px;\"><strong>Environnement r\u00e9glementaire<\/strong><\/td>\n<td style=\"padding: 8px;\">Am\u00e9rique du Nord (UL\/CSA), Europe (CE), projets mondiaux<\/td>\n<td style=\"padding: 8px;\">V\u00e9rifier UL 1059, IEC 60947-7-1 et marquage CE<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px;\"><strong>Maintenance Accessibilit\u00e9<\/strong><\/td>\n<td style=\"padding: 8px;\">Installations \u00e0 distance, bo\u00eetiers scell\u00e9s<\/td>\n<td style=\"padding: 8px;\">Bornes \u00e0 vis acceptables si accessibles ; bornes \u00e0 ressort si scell\u00e9es<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Guide d'application : Choisir le bon bornier<\/h2>\n<p>Faites correspondre le type de bornier aux exigences de l'application pour une performance, une s\u00e9curit\u00e9 et un co\u00fbt de cycle de vie optimaux.<\/p>\n<h3>Panneaux de contr\u00f4le industriels<\/h3>\n<p><strong>Exigences<\/strong>: Circuits de signaux et de puissance mixtes, modifications fr\u00e9quentes, vibrations provenant de moteurs \u00e0 proximit\u00e9<\/p>\n<p><strong>Solution recommand\u00e9e<\/strong>: Bornes \u00e0 ressort (6A-24A) pour les signaux ; bornes \u00e0 vis ou \u00e0 ressort (32A-76A) pour l'alimentation ; blocs multi-niveaux pour les E\/S denses<\/p>\n<h3>Automatisation du b\u00e2timent et CVC<\/h3>\n<p><strong>Exigences<\/strong>: Longue dur\u00e9e de vie, acc\u00e8s peu fr\u00e9quent, courants mod\u00e9r\u00e9s, conformit\u00e9 aux codes du b\u00e2timent<\/p>\n<p><strong>Solution recommand\u00e9e<\/strong>: Bornes \u00e0 vis (rentables pour les circuits de 10A \u00e0 20A) ; barrettes de connexion pour les raccordements au secteur ; bornes \u00e0 fusible pour la protection des d\u00e9rivations<\/p>\n<h3>Fabrication de machines et d'\u00e9quipements<\/h3>\n<p><strong>Exigences<\/strong>: Conception modulaire, assemblage rapide, conformit\u00e9 mondiale, facilit\u00e9 d'entretien<\/p>\n<p><strong>Solution recommand\u00e9e<\/strong>: Bornes \u00e0 insertion pour les circuits de commande (c\u00e2blage de production rapide) ; bornes \u00e0 ressort pour l'alimentation ; bornes de d\u00e9connexion pour les points de test ; certification UL + IEC<\/p>\n<h3>\u00c9nergie renouvelable (solaire, \u00e9olienne)<\/h3>\n<p><strong>Exigences<\/strong>: Exposition ext\u00e9rieure, r\u00e9sistance aux UV, haute tension (jusqu'\u00e0 1500V DC), cycles de temp\u00e9rature<\/p>\n<p><strong>Solution recommand\u00e9e<\/strong>: Borniers homologu\u00e9s PV (IEC 60947-7-4) ; grandes distances de fuite ; bornes \u00e0 ressort pour la r\u00e9sistance aux vibrations<\/p>\n<h3>Ferroviaire et transport<\/h3>\n<p><strong>Exigences<\/strong>: Vibrations extr\u00eames, chocs, plage de temp\u00e9rature (-40\u00b0C \u00e0 +85\u00b0C), s\u00e9curit\u00e9 incendie (EN 45545)<\/p>\n<p><strong>Solution recommand\u00e9e<\/strong>: Bornes \u00e0 ressort ou \u00e0 insertion ; mat\u00e9riaux ignifuges sans halog\u00e8ne ; contacts en acier inoxydable ; taux de cycles d'insertion \u00e9lev\u00e9s<\/p>\n<h3>Marine et offshore<\/h3>\n<p><strong>Exigences<\/strong>: R\u00e9sistance \u00e0 la corrosion, humidit\u00e9 \u00e9lev\u00e9e, brouillard salin, maintenance fr\u00e9quente<\/p>\n<p><strong>Solution recommand\u00e9e<\/strong>: Contacts en acier inoxydable ; bo\u00eetiers sp\u00e9ciaux en polyamide ou polycarbonate ; bornes \u00e0 insertion ou \u00e0 ressort ; bo\u00eetiers IP67<\/p>\n<figure style=\"text-align: center; margin: 20px 0;\"><img decoding=\"async\" style=\"max-width: 100%; height: auto;\" src=\"https:\/\/img.viox.com\/side-by-side-comparison-illustration-of-three-terminal-block-types-screw-terminal-spring-clamp-terminal-and-push-in-terminal.webp\" alt=\"Side-by-side comparison illustration of three terminal block types - screw terminal, spring-clamp terminal, and push-in terminal\" \/><figcaption style=\"color: #666; font-size: 0.9em; margin-top: 5px;\">Illustration comparative c\u00f4te \u00e0 c\u00f4te des types de bornes \u00e0 vis, de bornes \u00e0 ressort et de bornes \u00e0 insertion.<\/figcaption><\/figure>\n<h2>Installation et entretien<\/h2>\n<h3>Pr\u00e9paration du fil<\/h3>\n<ul>\n<li><strong>Longueur de la bande<\/strong>: Respecter les sp\u00e9cifications du fabricant (g\u00e9n\u00e9ralement 8-12mm pour les vis, 10-11mm pour les ressorts)<\/li>\n<li><strong>Embouts<\/strong>: Obligatoire pour les fils multibrins dans les bornes \u00e0 ressort et \u00e0 insertion ; am\u00e9liore le contact et emp\u00eache la rupture des brins<\/li>\n<li><strong>Torsion des fils<\/strong>: Ne jamais torsader les fils multibrins sans embouts - les brins individuels peuvent se casser et cr\u00e9er une r\u00e9sistance<\/li>\n<\/ul>\n<p>Les bornes \u00e0 vis n\u00e9cessitent des tournevis dynamom\u00e9triques calibr\u00e9s. Un serrage insuffisant provoque un \u00e9chauffement ; un serrage excessif endommage les conducteurs.<\/p>\n<table style=\"border-collapse: collapse; width: 100%; text-align: left;\" border=\"1\">\n<thead>\n<tr style=\"background-color: #f2f2f2;\">\n<th style=\"padding: 8px;\">Courant nominal du bornier<\/th>\n<th style=\"padding: 8px;\">Plage de couple typique<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"padding: 8px;\"><strong>6A \u2013 10A<\/strong><\/td>\n<td style=\"padding: 8px;\">0,5 \u2013 0,6 N\u00b7m<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px;\"><strong>17A \u2013 24A<\/strong><\/td>\n<td style=\"padding: 8px;\">0,8 \u2013 1,2 N\u00b7m<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px;\"><strong>32A \u2013 41A<\/strong><\/td>\n<td style=\"padding: 8px;\">1,2 \u2013 1,8 N\u00b7m<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px;\"><strong>57A \u2013 76A<\/strong><\/td>\n<td style=\"padding: 8px;\">2,0 \u2013 2,5 N\u00b7m<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 8px;\"><strong>101A+<\/strong><\/td>\n<td style=\"padding: 8px;\">3,0 \u2013 6,0 N\u00b7m<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>\u00c9tiquetage et maintenance<\/h3>\n<ul>\n<li>Utilisez des \u00e9tiquettes imprim\u00e9es identifiant la fonction du circuit ; maintenez les sch\u00e9mas de c\u00e2blage<\/li>\n<li>Code couleur des circuits (bleu pour le neutre, vert\/jaune pour la terre selon IEC 60446)<\/li>\n<li><strong>Bornes \u00e0 vis<\/strong>: Resserrer annuellement dans les environnements vibratoires<\/li>\n<li><strong>Ressort\/insertion<\/strong>: Inspection visuelle uniquement ; aucun resserrage requis<\/li>\n<li><strong>Tous types<\/strong>: Imagerie thermique lors de la mise en service<\/li>\n<\/ul>\n<h2>Foire Aux Questions<\/h2>\n<p><strong>Q : Quelle est la diff\u00e9rence entre un bornier et une barrette de connexion ?<\/strong><\/p>\n<p>R : \u201cBarrette de connexion\u201d et \u201cbarrette de barri\u00e8re\u201d se r\u00e9f\u00e8rent g\u00e9n\u00e9ralement \u00e0 des borniers \u00e0 une seule rang\u00e9e mont\u00e9s directement sur des panneaux avec des vis, plut\u00f4t que sur un rail DIN. Ils remplissent la m\u00eame fonction mais utilisent des m\u00e9thodes de montage diff\u00e9rentes.<\/p>\n<p><strong>Q : Puis-je m\u00e9langer des borniers \u00e0 vis et \u00e0 ressort sur le m\u00eame rail DIN ?<\/strong><\/p>\n<p>R : Oui. Le montage sur rail DIN permet de m\u00e9langer diff\u00e9rents types et marques tant que chacun r\u00e9pond aux sp\u00e9cifications requises pour son circuit.<\/p>\n<p><strong>Q : Les embouts sont-ils obligatoires pour les fils multibrins ?<\/strong><\/p>\n<p>R : Obligatoire pour les bornes \u00e0 ressort et \u00e0 insertion. Recommand\u00e9 mais pas toujours obligatoire pour les bornes \u00e0 vis, selon les sp\u00e9cifications du fabricant.<\/p>\n<p><strong>Q : Pourquoi les borniers ont-ils diff\u00e9rentes options de pas (espacement) ?<\/strong><\/p>\n<p>R : Le pas d\u00e9termine la capacit\u00e9 de courant et l'acc\u00e8s aux fils. Un pas \u00e9troit (5 mm) permet de gagner de la place pour les signaux de faible courant ; un pas large (10 mm+) permet d'accueillir des conducteurs plus grands et des courants plus \u00e9lev\u00e9s.<\/p>\n<p><strong>Q : Comment s\u00e9lectionner le courant nominal lorsque la taille du conducteur se situe entre deux valeurs nominales standard ?<\/strong><\/p>\n<p>R : S\u00e9lectionnez toujours le bornier dont le courant nominal correspond \u00e0 la taille de conducteur imm\u00e9diatement sup\u00e9rieure. Ne jamais d\u00e9passer le courant nominal, m\u00eame si le fil peut physiquement s'ins\u00e9rer.<\/p>\n<p><strong>Q : Que signifie la mention \u201cprot\u00e9g\u00e9 contre les contacts accidentels\u201d ou IP20 pour les borniers ?<\/strong><\/p>\n<p>R : IP20 (IEC 60529) offre une protection contre les contacts accidentels avec des pi\u00e8ces sous tension par les doigts ou des objets de &gt;12,5 mm de diam\u00e8tre. De nombreux borniers comprennent des couvercles amovibles ou des contacts encastr\u00e9s pour r\u00e9pondre \u00e0 cette exigence.<\/p>\n<h2>Conclusion<\/h2>\n<p>Les borniers transforment le c\u00e2blage des panneaux, passant de connexions point \u00e0 point ad hoc \u00e0 des syst\u00e8mes \u00e9lectriques organis\u00e9s, testables et maintenables. Le choix du bon type - qu'il s'agisse d'un serrage \u00e0 vis, \u00e0 ressort ou \u00e0 insertion ; d'une fonction de passage, de d\u00e9connexion ou de fusible ; d'une configuration standard ou multi-niveaux - d\u00e9pend des caract\u00e9ristiques \u00e9lectriques, de l'environnement d'installation, de l'acc\u00e8s pour la maintenance et des exigences du cycle de vie.<\/p>\n<p><strong>VIOX \u00c9lectrique<\/strong> fabrique une gamme compl\u00e8te de borniers pour rail DIN conformes aux normes IEC 60947-7-1 et UL 1059. Notre gamme de produits comprend des borniers \u00e0 vis, \u00e0 ressort et \u00e0 insertion avec des courants nominaux de 6A \u00e0 400A, destin\u00e9s \u00e0 l'automatisation industrielle, \u00e0 la distribution d'\u00e9nergie, aux syst\u00e8mes de b\u00e2timent et aux applications sp\u00e9cialis\u00e9es.<\/p>\n<p>Que vous sp\u00e9cifiiez des composants de panneau de commande, que vous achetiez du mat\u00e9riel de remplacement ou que vous conceviez de nouveaux \u00e9quipements, notre \u00e9quipe technique vous fournit des conseils d'application et des solutions personnalis\u00e9es pour vos besoins en borniers.<\/p>\n<p><strong>Contacter VIOX Electric<\/strong> d\u00e8s aujourd'hui pour discuter des sp\u00e9cifications de votre projet et recevoir des recommandations d'experts pour des solutions de borniers fiables et conformes aux normes.<\/p>\n<\/div>\n<div class=\"simg-pop-btn\" style=\"top: 765.344px; left: 14.0078px; display: none;\"><\/div>\n<div class=\"simg-pop-btn\" style=\"top: 765.344px; left: 14.0078px; display: none;\"><\/div>\n<div class=\"simg-pop-btn\" style=\"top: 5696.14px; left: 14.0078px; display: none;\"><\/div>\n<div class=\"simg-pop-btn\" style=\"top: 5696.14px; left: 14.0078px; display: none;\"><\/div>\n<div class=\"simg-pop-btn\" style=\"top: 8571.74px; left: 14.0078px; display: none;\"><\/div>\n<div class=\"simg-pop-btn\" style=\"top: 8571.74px; left: 14.0078px; display: none;\"><\/div>","protected":false},"excerpt":{"rendered":"<p>Specifying terminal blocks for an industrial panel should be straightforward. But when procurement emails ask whether to use screw terminals or spring-clamp, or when specifications list &#8220;barrier blocks&#8221; without context, clarity becomes critical. Electrical engineers need precise selection criteria. Contractors need assurance they&#8217;re ordering the right hardware. Facility managers want terminations that stay secure through [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":20876,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1],"tags":[],"class_list":["post-20874","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"_links":{"self":[{"href":"https:\/\/test.viox.com\/fr\/wp-json\/wp\/v2\/posts\/20874","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/test.viox.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/test.viox.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/test.viox.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/test.viox.com\/fr\/wp-json\/wp\/v2\/comments?post=20874"}],"version-history":[{"count":1,"href":"https:\/\/test.viox.com\/fr\/wp-json\/wp\/v2\/posts\/20874\/revisions"}],"predecessor-version":[{"id":20875,"href":"https:\/\/test.viox.com\/fr\/wp-json\/wp\/v2\/posts\/20874\/revisions\/20875"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/test.viox.com\/fr\/wp-json\/wp\/v2\/media\/20876"}],"wp:attachment":[{"href":"https:\/\/test.viox.com\/fr\/wp-json\/wp\/v2\/media?parent=20874"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/test.viox.com\/fr\/wp-json\/wp\/v2\/categories?post=20874"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/test.viox.com\/fr\/wp-json\/wp\/v2\/tags?post=20874"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}