{"id":19015,"date":"2025-07-28T14:33:59","date_gmt":"2025-07-28T06:33:59","guid":{"rendered":"https:\/\/viox.com\/?p=19015"},"modified":"2026-01-19T09:07:47","modified_gmt":"2026-01-19T01:07:47","slug":"dc-isolator-vs-ac-isolator-switch","status":"publish","type":"post","link":"https:\/\/test.viox.com\/fr\/dc-isolator-vs-ac-isolator-switch\/","title":{"rendered":"Isolateur CC vs interrupteur d&#039;isolement CA\u00a0: guide comparatif complet pour des installations \u00e9lectriques s\u00fbres"},"content":{"rendered":"<div class=\"product-intro\">\n<div style=\"background-color: #f9f9f9; border-left: 5px solid #fd041a; padding: 20px; margin-bottom: 30px;\">\n<h2 style=\"margin-top: 0;\">Principaux enseignements<\/h2>\n<ul style=\"margin-bottom: 0;\">\n<li><strong>Facteur de passage par z\u00e9ro :<\/strong> Le courant alternatif \u00e9teint naturellement les arcs aux passages par z\u00e9ro (100 \u00e0 120 fois par seconde), tandis que le courant continu maintient les arcs en permanence.<\/li>\n<li><strong>Diff\u00e9rences de conception :<\/strong> Les sectionneurs CC n\u00e9cessitent des bobines d'extinction magn\u00e9tique et des chambres de coupure d'arc profondes, ce qui les rend physiquement plus grands et plus co\u00fbteux que les versions CA.<\/li>\n<li><strong>D\u00e9classement de tension :<\/strong> L'utilisation d'un sectionneur CA pour des applications CC entra\u00eene une baisse significative de la capacit\u00e9 de tension (par exemple, 690 V CA \u2192 ~220 V CC).<\/li>\n<li><strong>R\u00e8gle de s\u00e9curit\u00e9 :<\/strong> N'utilisez jamais un sectionneur de tension alternative pour les syst\u00e8mes CC tels que le solaire photovolta\u00efque ou le stockage de batteries afin d'\u00e9viter les risques d'incendie et le soudage des contacts.<\/li>\n<\/ul>\n<\/div>\n<p>Le technicien de maintenance ouvre l'interrupteur sectionneur. 600 volts, 32 amp\u00e8res. Proc\u00e9dure de consignation de routine pour un ensemble solaire sur le toit.<\/p>\n<p>Sauf que l'interrupteur n'\u00e9tait pas con\u00e7u pour le courant continu.<\/p>\n<p>\u00c0 l'int\u00e9rieur du bo\u00eetier, un arc se forme entre les contacts qui se s\u00e9parent : un pont de plasma brillant et soutenu conduisant 600 V CC \u00e0 travers l'air ionis\u00e9. Dans un syst\u00e8me CA, cet arc s'\u00e9teindrait naturellement en 10 millisecondes, \u00e9touff\u00e9 au prochain passage \u00e0 z\u00e9ro du courant. Mais le courant continu n'a pas de passage \u00e0 z\u00e9ro. L'arc se maintient. Les contacts commencent \u00e0 s'\u00e9roder. La temp\u00e9rature augmente. En quelques secondes, l'isolateur qui \u00e9tait cens\u00e9 assurer une d\u00e9connexion s\u00fbre devient un conducteur continu \u00e0 haute tension, exactement au moment o\u00f9 vous avez le plus besoin qu'il soit isol\u00e9.<\/p>\n<p>C'est <strong>\u201c Le filet de s\u00e9curit\u00e9 du passage \u00e0 z\u00e9ro \u201d<\/strong>\u2014 Le courant alternatif l'a, le courant continu ne l'a pas. Et cela change tout dans la fa\u00e7on dont les interrupteurs sectionneurs doivent \u00eatre con\u00e7us, \u00e9valu\u00e9s et s\u00e9lectionn\u00e9s.<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-19021\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/isolator-switches.webp\" alt=\"isolator switches\" width=\"800\" height=\"600\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/isolator-switches.webp 800w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/isolator-switches-300x225.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/isolator-switches-768x576.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/isolator-switches-16x12.webp 16w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/isolator-switches-600x450.webp 600w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<h2>Que sont les interrupteurs isolateurs\u00a0?<\/h2>\n<p>Un <strong><a href=\"https:\/\/test.viox.com\/fr\/what-is-a-dc-isolator-switch\/\">interrupteur d&#039;isolement<\/a><\/strong> (\u00e9galement appel\u00e9 interrupteur sectionneur ou sectionneur) est un dispositif de commutation m\u00e9canique con\u00e7u pour isoler un circuit \u00e9lectrique de sa source d'alimentation, assurant ainsi la s\u00e9curit\u00e9 de la maintenance et des r\u00e9parations. R\u00e9glement\u00e9 par <a href=\"https:\/\/test.viox.com\/fr\/iec-60947-3-utilization-categories-guide\/\">IEC 60947-3:2020<\/a> pour les appareillages basse tension (jusqu'\u00e0 1000 V CA et 1500 V CC), les sectionneurs offrent une d\u00e9connexion visible (un espace physique que vous pouvez voir ou v\u00e9rifier) entre les conducteurs sous tension et l'\u00e9quipement en aval.<\/p>\n<p>Contrairement aux <a href=\"https:\/\/test.viox.com\/fr\/circuit-breaker-vs-isolator-switch\/\">disjoncteurs<\/a>, les sectionneurs ne sont pas con\u00e7us pour interrompre les courants de d\u00e9faut sous charge. Ce sont des sectionneurs de maintenance. Vous les ouvrez lorsque le circuit est hors tension ou qu'il transporte une charge minimale, cr\u00e9ant ainsi un point d'isolation s\u00fbr pour les travaux en aval. La plupart des sectionneurs comprennent un m\u00e9canisme de verrouillage (moraillon de cadenas ou poign\u00e9e verrouillable) pour la conformit\u00e9 LOTO (Lockout\/Tagout).<\/p>\n<p>Voici ce qui rend la s\u00e9lection du sectionneur essentielle : la physique de <strong>l'interruption d'arc<\/strong>\u2014 ce qui se passe dans les microsecondes apr\u00e8s l'ouverture de l'interrupteur \u2014 est fondamentalement diff\u00e9rent pour le courant alternatif et le courant continu. Un sectionneur ad\u00e9quat pour le service CA peut \u00eatre totalement inad\u00e9quat (et dangereux) pour le service CC, m\u00eame \u00e0 une tension plus faible. La plaque signal\u00e9tique peut indiquer \u201c 690 V \u201d, mais il s'agit de 690 V <em>AC<\/em>. CA. L'utiliser sur une cha\u00eene solaire de 600 V CC ? Vous venez de cr\u00e9er un risque potentiel d'arc \u00e9lectrique.<\/p>\n<p>Ce n'est pas un d\u00e9tail technique mineur ou une marge de s\u00e9curit\u00e9 prudente. C'est de la physique. Et comprendre pourquoi n\u00e9cessite d'examiner ce qui se passe \u00e0 l'int\u00e9rieur de chaque interrupteur lorsque les contacts se s\u00e9parent sous tension.<\/p>\n<p><strong>Pro-Tip #1:<\/strong> N'utilisez jamais un sectionneur con\u00e7u pour le courant alternatif pour des applications en courant continu, sauf si sa fiche technique indique explicitement les valeurs nominales de tension\/courant en courant continu. Un sectionneur de 690 V CA a g\u00e9n\u00e9ralement une capacit\u00e9 CC de seulement 220 \u00e0 250 V CC, soit moins qu'une cha\u00eene solaire \u00e0 4 panneaux en circuit ouvert.<\/p>\n<h2>Le probl\u00e8me de l'extinction de l'arc : pourquoi le courant continu est diff\u00e9rent<\/h2>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-20304\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/viox-isolator-principle.svg\" alt=\"VIOX Isolator Switch Principle\" width=\"800\" height=\"680\" \/><\/p>\n<p>Lorsque vous ouvrez un interrupteur sous tension, un arc se forme. C'est in\u00e9vitable. Lorsque les contacts se s\u00e9parent, l'espace entre eux est encore suffisamment petit (microm\u00e8tres, puis millim\u00e8tres) pour que la tension ionise l'air, cr\u00e9ant ainsi un canal de plasma conducteur. Le courant continue de circuler \u00e0 travers cet arc m\u00eame si les contacts m\u00e9caniques ne se touchent plus.<\/p>\n<p>Pour que l'interrupteur isole v\u00e9ritablement le circuit, cet arc doit \u00eatre <strong>\u00e9teint<\/strong>. Et c'est l\u00e0 que le courant alternatif et le courant continu divergent compl\u00e8tement.<\/p>\n<h3>CA : Le passage \u00e0 z\u00e9ro naturel<\/h3>\n<p>Le courant alternatif, comme son nom l'indique, alterne. Un syst\u00e8me CA de 50 Hz franchit la tension\/le courant z\u00e9ro 100 fois par seconde. Un syst\u00e8me de 60 Hz franchit le z\u00e9ro 120 fois par seconde. Toutes les 8,33 millisecondes (60 Hz) ou 10 millisecondes (50 Hz), le flux de courant inverse sa direction et passe par z\u00e9ro.<\/p>\n<p>Au passage \u00e0 z\u00e9ro du courant, il n'y a pas d'\u00e9nergie pour maintenir l'arc. Le plasma se d\u00e9sionise. L'arc s'\u00e9teint. Si les contacts se sont suffisamment s\u00e9par\u00e9s au cycle suivant, la rigidit\u00e9 di\u00e9lectrique de l'espace (sa capacit\u00e9 \u00e0 supporter la tension sans r\u00e9amor\u00e7age) d\u00e9passe la tension du syst\u00e8me. L'arc ne se r\u00e9amorce pas. L'isolation est atteinte.<\/p>\n<p>C'est <strong>\u201c Le filet de s\u00e9curit\u00e9 du passage \u00e0 z\u00e9ro. \u201d<\/strong> Les sectionneurs CA peuvent compter sur cette interruption naturelle. La conception de leurs contacts, la distance entre les espaces et la g\u00e9om\u00e9trie de la chambre d'arc n'ont qu'\u00e0 garantir que l'arc ne se r\u00e9amorce pas apr\u00e8s le prochain passage \u00e0 z\u00e9ro. C'est un probl\u00e8me de conception relativement tol\u00e9rant.<\/p>\n<h3>CC : Le probl\u00e8me de l'arc sans fin<\/h3>\n<p>Le courant continu n'a pas de passage \u00e0 z\u00e9ro. Jamais. Une cha\u00eene solaire de 600 V CC fournit 600 volts en continu. Lorsque les contacts du sectionneur se s\u00e9parent et qu'un arc se forme, cet arc est maintenu par une \u00e9nergie continue. Il n'y a pas de point d'interruption naturelle. L'arc se poursuivra ind\u00e9finiment jusqu'\u00e0 ce que l'une des trois choses suivantes se produise :<\/p>\n<ol>\n<li><strong>L'espace entre les contacts devient suffisamment grand<\/strong> pour que m\u00eame l'arc ne puisse pas le franchir (ce qui n\u00e9cessite une s\u00e9paration physique beaucoup plus importante qu'en CA)<\/li>\n<li><strong>L'arc est \u00e9tir\u00e9 m\u00e9caniquement, refroidi et souffl\u00e9<\/strong> \u00e0 l'aide de champs magn\u00e9tiques et de cages d'arc<\/li>\n<li><strong>Les contacts se soudent ensemble<\/strong> en raison du chauffage continu, ce qui annule tout l'objectif de l'isolation<\/li>\n<\/ol>\n<p>L'option 3 est ce qui se passe lorsque vous utilisez un sectionneur con\u00e7u pour le courant alternatif dans un service en courant continu. La vitesse de s\u00e9paration des contacts et la distance entre les espaces qui fonctionnent bien pour le courant alternatif (car le prochain passage \u00e0 z\u00e9ro arrive dans 10 millisecondes) sont insuffisantes pour le courant continu. L'arc se maintient. L'\u00e9rosion des contacts s'acc\u00e9l\u00e8re. Dans le pire des cas, les contacts se soudent et vous perdez compl\u00e8tement l'isolation.<\/p>\n<p><strong>Pro-Tip #2:<\/strong> Le courant alternatif franchit le z\u00e9ro 100 fois par seconde (50 Hz) ou 120 fois (60 Hz) : chaque passage \u00e0 z\u00e9ro est une occasion pour l'arc de s'\u00e9teindre naturellement. Le courant continu ne franchit jamais le z\u00e9ro. Ce n'est pas une diff\u00e9rence mineure : c'est pourquoi les sectionneurs CC ont besoin de bobines d'extinction magn\u00e9tique et de cages d'arc profondes que les sectionneurs CA n'ont pas.<\/p>\n<figure><img decoding=\"async\" class=\"alignnone size-full wp-image-20305\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/AC-vs-DC-Arc-Extinction-Mechanisms.webp\" alt=\"AC vs DC Arc Extinction Mechanisms\" width=\"800\" height=\"450\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/AC-vs-DC-Arc-Extinction-Mechanisms.webp 800w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/AC-vs-DC-Arc-Extinction-Mechanisms-300x169.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/AC-vs-DC-Arc-Extinction-Mechanisms-768x432.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/AC-vs-DC-Arc-Extinction-Mechanisms-18x10.webp 18w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/AC-vs-DC-Arc-Extinction-Mechanisms-600x338.webp 600w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><figcaption>Figure 1 : M\u00e9canismes d'extinction d'arc CA et CC. Le courant alternatif franchit le z\u00e9ro 100 \u00e0 120 fois par seconde, ce qui fournit des points d'interruption d'arc naturels. Le courant continu ne franchit jamais le z\u00e9ro : les arcs se maintiennent en continu jusqu'\u00e0 ce qu'ils soient \u00e9teints m\u00e9caniquement.<\/figcaption><\/figure>\n<h2>Conception du sectionneur CC : Le guerrier de la chambre d'arc<\/h2>\n<p>\u00c9tant donn\u00e9 que les arcs CC ne s'\u00e9teignent pas d'eux-m\u00eames, les sectionneurs CC doivent forcer l'extinction par des moyens m\u00e9caniques agressifs. C'est <strong>\u201c Le guerrier de la chambre d'arc \u201d<\/strong>\u2014 un sectionneur CC est con\u00e7u pour la bataille.<\/p>\n<h3>Bobines d'extinction magn\u00e9tique<\/h3>\n<p>La plupart des sectionneurs CC int\u00e8grent <strong>des bobines d'extinction magn\u00e9tique<\/strong> ou des aimants permanents positionn\u00e9s pr\u00e8s des contacts. Lorsqu'un arc se forme, le champ magn\u00e9tique interagit avec le courant d'arc (qui est une charge en mouvement), produisant une force de Lorentz qui pousse l'arc loin des contacts et dans la chambre d'extinction d'arc.<\/p>\n<p>Consid\u00e9rez cela comme une main magn\u00e9tique qui pousse physiquement l'arc loin de l'endroit o\u00f9 il veut rester. Plus vous d\u00e9placez l'arc rapidement et loin, plus il se refroidit et s'\u00e9tire, jusqu'\u00e0 ce qu'il ne puisse plus se maintenir.<\/p>\n<h3>Cages d'arc (plaques de s\u00e9paration)<\/h3>\n<p>Une fois que l'arc est souffl\u00e9 dans la chambre d'arc, il rencontre <strong>des cages d'arc<\/strong>\u2014 des r\u00e9seaux de plaques m\u00e9talliques (souvent en cuivre) qui divisent l'arc en plusieurs segments plus courts. Chaque segment a sa propre chute de tension. Lorsque la chute de tension totale \u00e0 travers tous les segments d\u00e9passe la tension du syst\u00e8me, l'arc ne peut plus se maintenir. Il s'effondre.<\/p>\n<p>Les sectionneurs CC utilisent des conceptions de cages d'arc plus profondes et plus agressives que les sectionneurs CA, car ils ne peuvent pas compter sur les passages \u00e0 z\u00e9ro du courant. L'arc doit \u00eatre \u00e9teint de force \u00e0 plein courant, \u00e0 chaque fois.<\/p>\n<h3>Mat\u00e9riaux de contact \u00e0 haute teneur en argent<\/h3>\n<p>Les arcs CC sont brutaux pour les contacts. L'amor\u00e7age continu \u00e0 pleine tension provoque une \u00e9rosion et un chauffage rapides. Pour r\u00e9sister \u00e0 cela, les sectionneurs CC utilisent des mat\u00e9riaux de contact avec une teneur en argent plus \u00e9lev\u00e9e (souvent des alliages argent-tungst\u00e8ne ou argent-nickel) qui r\u00e9sistent mieux \u00e0 la soudure et \u00e0 l'\u00e9rosion que les contacts en cuivre ou en laiton courants dans les sectionneurs CA.<\/p>\n<p>Le r\u00e9sultat ? Un sectionneur CC de 1000 V CC \u00e0 32 A est physiquement plus grand, plus lourd, plus complexe et co\u00fbte 2 \u00e0 3 fois plus cher qu'un sectionneur CA de m\u00eame calibre. Ce n'est pas une tarification arbitraire : c'est le co\u00fbt d'ing\u00e9nierie de l'extinction forc\u00e9e de l'arc sans passage \u00e0 z\u00e9ro.<\/p>\n<p><strong>Pro-Tip #3:<\/strong> Pour les syst\u00e8mes photovolta\u00efques, v\u00e9rifiez toujours que la tension nominale CC du sectionneur d\u00e9passe la tension maximale en circuit ouvert (Voc) de votre cha\u00eene \u00e0 la temp\u00e9rature la plus basse pr\u00e9vue. Une cha\u00eene de 10 panneaux de modules de 400 W peut atteindre 500 \u00e0 600 V CC \u00e0 -10 \u00b0C, ce qui d\u00e9passe la capacit\u00e9 de nombreux sectionneurs \u201c compatibles CC \u201d. Consultez \u00e9galement notre guide sur <a href=\"https:\/\/test.viox.com\/fr\/connection-of-dc-isolators\/\">Connexion des sectionneurs CC<\/a> pour conna\u00eetre les pratiques de c\u00e2blage s\u00fbres.<\/p>\n<figure><\/figure>\n<figure><div id='gallery-1' class='gallery galleryid-19015 gallery-columns-3 gallery-size-full'><figure class='gallery-item'>\n\t\t\t<div class='gallery-icon landscape'>\n\t\t\t\t<a href='https:\/\/test.viox.com\/fr\/?attachment_id=14986'><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"800\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VOPV-DC-Isolator-Switch-NL1_T-Series-1.webp\" class=\"attachment-full size-full\" alt=\"VOPV DC Isolator Switch NL1_T Series\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VOPV-DC-Isolator-Switch-NL1_T-Series-1.webp 800w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VOPV-DC-Isolator-Switch-NL1_T-Series-1-300x300.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VOPV-DC-Isolator-Switch-NL1_T-Series-1-150x150.webp 150w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VOPV-DC-Isolator-Switch-NL1_T-Series-1-768x768.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VOPV-DC-Isolator-Switch-NL1_T-Series-1-12x12.webp 12w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VOPV-DC-Isolator-Switch-NL1_T-Series-1-600x600.webp 600w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VOPV-DC-Isolator-Switch-NL1_T-Series-1-100x100.webp 100w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/elementor\/thumbs\/VOPV-DC-Isolator-Switch-NL1_T-Series-1-r3ntkz9aljrq1yjgy0uif02c7rkuczs5lic1glcknc.webp 500w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/a>\n\t\t\t<\/div><\/figure><figure class='gallery-item'>\n\t\t\t<div class='gallery-icon landscape'>\n\t\t\t\t<a href='https:\/\/test.viox.com\/fr\/?attachment_id=14983'><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"800\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VOPV-DC-Isolator-Switch-NL1_T-Series.webp\" class=\"attachment-full size-full\" alt=\"VOPV DC Isolator Switch NL1 Series\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VOPV-DC-Isolator-Switch-NL1_T-Series.webp 800w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VOPV-DC-Isolator-Switch-NL1_T-Series-300x300.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VOPV-DC-Isolator-Switch-NL1_T-Series-150x150.webp 150w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VOPV-DC-Isolator-Switch-NL1_T-Series-768x768.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VOPV-DC-Isolator-Switch-NL1_T-Series-12x12.webp 12w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VOPV-DC-Isolator-Switch-NL1_T-Series-600x600.webp 600w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VOPV-DC-Isolator-Switch-NL1_T-Series-100x100.webp 100w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/a>\n\t\t\t<\/div><\/figure><figure class='gallery-item'>\n\t\t\t<div class='gallery-icon landscape'>\n\t\t\t\t<a href='https:\/\/test.viox.com\/fr\/vopv-dc-isolator-switch-l2-series\/'><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"800\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VOPV-DC-Isolator-Switch-L2-Series.webp\" class=\"attachment-full size-full\" alt=\"VOPV DC Isolator Switch L2 Series\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VOPV-DC-Isolator-Switch-L2-Series.webp 800w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VOPV-DC-Isolator-Switch-L2-Series-300x300.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VOPV-DC-Isolator-Switch-L2-Series-150x150.webp 150w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VOPV-DC-Isolator-Switch-L2-Series-768x768.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VOPV-DC-Isolator-Switch-L2-Series-12x12.webp 12w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VOPV-DC-Isolator-Switch-L2-Series-600x600.webp 600w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/03\/VOPV-DC-Isolator-Switch-L2-Series-100x100.webp 100w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/a>\n\t\t\t<\/div><\/figure>\n\t\t<\/div>\n<figcaption>Figure 2 : <a href=\"https:\/\/test.viox.com\/fr\/dc-isolator-switch\/\">Produit de sectionneur CC r\u00e9el<\/a>. Ce sectionneur CC industriel de 1000 V CC et 32 A montre la construction substantielle requise pour les applications photovolta\u00efques.<\/figcaption><\/figure>\n<h2>Conception du sectionneur CA : Surfer sur le passage \u00e0 z\u00e9ro<\/h2>\n<p>Les sectionneurs CA sont, en comparaison, simples. Ils n'ont pas besoin de bobines d'extinction magn\u00e9tique (bien que certains en incluent pour une interruption plus rapide). Ils n'ont pas besoin de cages d'arc profondes. Ils n'ont pas besoin de mat\u00e9riaux de contact exotiques.<\/p>\n<p>Pourquoi ? Parce que <strong>le passage \u00e0 z\u00e9ro fait l'essentiel du travail<\/strong>. Le travail du sectionneur CA n'est pas d'\u00e9teindre de force l'arc, mais de s'assurer que l'arc ne se r\u00e9amorce pas apr\u00e8s l'interruption naturelle du passage \u00e0 z\u00e9ro.<\/p>\n<ul>\n<li><strong>Distance d'espacement suffisante :<\/strong> G\u00e9n\u00e9ralement 3 \u00e0 6 mm pour le courant alternatif basse tension, selon la tension et le degr\u00e9 de pollution<\/li>\n<li><strong>Confinement d'arc de base :<\/strong> Barri\u00e8res isolantes simples pour emp\u00eacher le cheminement d'arc sur les surfaces<\/li>\n<\/ul>\n<p>C'est tout. Les sectionneurs CA comptent sur la forme d'onde pour faire le gros du travail. La conception m\u00e9canique doit juste suivre le rythme. Pour des applications sp\u00e9cifiques comme les moteurs triphas\u00e9s, consultez notre <a href=\"https:\/\/test.viox.com\/fr\/complete-guide-to-3-phase-isolator-switch\/\">Guide complet des sectionneurs triphas\u00e9s<\/a>.<\/p>\n<figure><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-20308 aligncenter\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/ac-isolator-switch.webp\" alt=\"ac isolator switch\" width=\"353\" height=\"446\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/ac-isolator-switch.webp 806w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/ac-isolator-switch-238x300.webp 238w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/ac-isolator-switch-768x970.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/ac-isolator-switch-10x12.webp 10w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/ac-isolator-switch-600x758.webp 600w\" sizes=\"(max-width: 353px) 100vw, 353px\" \/><figcaption>Figure 4 : Conception d'un sectionneur AC (Surfant sur le passage \u00e0 z\u00e9ro). Ce sectionneur AC triphas\u00e9 pr\u00e9sente une construction externe consid\u00e9rablement plus simple, sans complexit\u00e9 visible de la chambre d'arc.<\/figcaption><\/figure>\n<h2>La p\u00e9nalit\u00e9 de r\u00e9duction de tension<\/h2>\n<p>Voici une surprise qui surprend de nombreux ing\u00e9nieurs : si vous <em>doit<\/em> utilisez un sectionneur con\u00e7u pour AC pour du DC (ce que vous ne devriez pas faire, mais hypoth\u00e9tiquement), sa capacit\u00e9 de tension DC est consid\u00e9rablement inf\u00e9rieure \u00e0 sa tension nominale AC. C'est <strong>\u201cLa p\u00e9nalit\u00e9 de r\u00e9duction de tension.\u201d<\/strong><\/p>\n<p>Un sch\u00e9ma typique :<\/p>\n<ul>\n<li>Tension nominale de 690V AC \u2192 capacit\u00e9 d'environ 220-250V DC<\/li>\n<li>Tension nominale de 400V AC \u2192 capacit\u00e9 d'environ 150-180V DC<\/li>\n<li>Tension nominale de 230V AC \u2192 capacit\u00e9 d'environ 80-110V DC<\/li>\n<\/ul>\n<p>Pourquoi une r\u00e9duction aussi s\u00e9v\u00e8re ? Parce que la tension d'arc DC est fondamentalement diff\u00e9rente de la tension d'arc AC. Les fabricants en tiennent compte en r\u00e9duisant consid\u00e9rablement la tension nominale DC.<\/p>\n<p>Pour les applications solaires photovolta\u00efques, c'est <strong>\u201cLe pi\u00e8ge des cha\u00eenes PV.\u201d<\/strong> Un panneau solaire courant de 400W a une tension en circuit ouvert (Voc) d'environ 48-50V en STC. Cha\u00eene de 10 panneaux ensemble : 480-500V. Mais la Voc augmente \u00e0 des temp\u00e9ratures plus basses. Un sectionneur AC de 400V avec une tension nominale DC de 180V ? Compl\u00e8tement inad\u00e9quat.<\/p>\n<p><strong>Pro-Tip #4:<\/strong> Les sectionneurs sont con\u00e7us pour la commutation \u00e0 vide ou \u00e0 charge minimale : ce sont des sectionneurs de maintenance, pas des protections contre les surintensit\u00e9s. Pour les environnements n\u00e9cessitant une protection contre les intemp\u00e9ries, assurez-vous de bien comprendre <a href=\"https:\/\/test.viox.com\/fr\/indoor-outdoor-isolator-switch-ip-ratings\/\">Indices de protection IP pour les sectionneurs<\/a>.<\/p>\n<figure><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-20307\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/The-Voltage-Derating-Penalty-graph.webp\" alt=\"The Voltage Derating Penalty graph\" width=\"800\" height=\"450\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/The-Voltage-Derating-Penalty-graph.webp 800w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/The-Voltage-Derating-Penalty-graph-300x169.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/The-Voltage-Derating-Penalty-graph-768x432.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/The-Voltage-Derating-Penalty-graph-18x10.webp 18w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/The-Voltage-Derating-Penalty-graph-600x338.webp 600w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><figcaption>Figure 5 : La p\u00e9nalit\u00e9 de r\u00e9duction de tension. Les sectionneurs con\u00e7us pour AC perdent 60 \u00e0 70 % de leur capacit\u00e9 de tension lorsqu'ils sont utilis\u00e9s pour des applications DC.<\/figcaption><\/figure>\n<h2>Sectionneur DC vs AC : Comparaison des sp\u00e9cifications cl\u00e9s<\/h2>\n<table border=\"1\" cellspacing=\"0\" cellpadding=\"10\">\n<thead>\n<tr>\n<th>Sp\u00e9cification<\/th>\n<th>Isolateur CA<\/th>\n<th>Isolateur DC<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>M\u00e9canisme d'extinction de l'arc<\/strong><\/td>\n<td>Passage \u00e0 z\u00e9ro de courant naturel (100-120 fois\/sec)<\/td>\n<td>Extinction m\u00e9canique forc\u00e9e (soufflage magn\u00e9tique + chambres d'arc)<\/td>\n<\/tr>\n<tr>\n<td><strong>Intervalle de contact requis<\/strong><\/td>\n<td>3-6mm (varie selon la tension)<\/td>\n<td>8-15mm (intervalle plus grand pour la m\u00eame tension)<\/td>\n<\/tr>\n<tr>\n<td><strong>Conception de la chambre d'arc<\/strong><\/td>\n<td>Minimal ou nul<\/td>\n<td>Plaques de s\u00e9paration profondes, g\u00e9om\u00e9trie agressive<\/td>\n<\/tr>\n<tr>\n<td><strong>Soufflage magn\u00e9tique<\/strong><\/td>\n<td>Optionnel (pour une interruption rapide)<\/td>\n<td>Obligatoire (aimants permanents ou bobines)<\/td>\n<\/tr>\n<tr>\n<td><strong>Mat\u00e9riau de contact<\/strong><\/td>\n<td>Cuivre, laiton, alliages standard<\/td>\n<td>Teneur \u00e9lev\u00e9e en argent (alliages Ag-W, Ag-Ni)<\/td>\n<\/tr>\n<tr>\n<td><strong>Exemple de tension nominale<\/strong><\/td>\n<td>690V AC<\/td>\n<td>1000V DC ou 1500V DC<\/td>\n<\/tr>\n<tr>\n<td><strong>Exemple de courant nominal<\/strong><\/td>\n<td>32A, 63A, 125A typique<\/td>\n<td>16A-1600A (plage plus large pour PV\/ESS)<\/td>\n<\/tr>\n<tr>\n<td><strong>Les Applications Typiques<\/strong><\/td>\n<td>Contr\u00f4le de moteur, CVC, distribution AC industrielle<\/td>\n<td>Solaire PV, stockage de batterie, recharge de VE, microgrids DC<\/td>\n<\/tr>\n<tr>\n<td><strong>Normes<\/strong><\/td>\n<td>IEC 60947-3:2020 (cat\u00e9gories d'utilisation AC)<\/td>\n<td>IEC 60947-3:2020 (cat\u00e9gories d'utilisation DC : DC-21B, DC-PV2)<\/td>\n<\/tr>\n<tr>\n<td><strong>De Taille Et De Poids<\/strong><\/td>\n<td>Compact, l\u00e9ger<\/td>\n<td>Plus grand, plus lourd (2-3\u00d7 la taille pour le m\u00eame courant nominal)<\/td>\n<\/tr>\n<tr>\n<td><strong>Co\u00fbt<\/strong><\/td>\n<td>Inf\u00e9rieur (de base)<\/td>\n<td>2-3\u00d7 plus cher<\/td>\n<\/tr>\n<tr>\n<td><strong>Dur\u00e9e de l'arc \u00e0 l'ouverture<\/strong><\/td>\n<td>&lt;10ms (jusqu&#039;au prochain passage \u00e0 z\u00e9ro)<\/td>\n<td>Continu jusqu'\u00e0 l'extinction m\u00e9canique<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Principaux enseignements :<\/strong> La \u201cp\u00e9nalit\u00e9 de co\u00fbt de 2 \u00e0 3\u00d7\u201d pour les sectionneurs DC n'est pas une majoration de prix - elle refl\u00e8te la taxe de physique fondamentale de l'extinction des arcs sans passages \u00e0 z\u00e9ro.<\/p>\n<h2>Quand utiliser des sectionneurs DC vs AC<\/h2>\n<p>La d\u00e9cision ne concerne pas la pr\u00e9f\u00e9rence ou l'optimisation des co\u00fbts - il s'agit d'adapter la capacit\u00e9 d'extinction d'arc du sectionneur au type de courant de votre syst\u00e8me.<\/p>\n<h3>Utilisez des sectionneurs DC pour :<\/h3>\n<p><strong>1. Syst\u00e8mes solaires photovolta\u00efques (PV)<\/strong><br \/>\nChaque cha\u00eene CC de panneaux solaires n\u00e9cessite une isolation entre les panneaux et l'onduleur. Les tensions des cha\u00eenes atteignent couramment 600 \u00e0 1000 V CC. Recherchez la cat\u00e9gorie d'utilisation CEI 60947-3 DC-PV2 sp\u00e9cialement con\u00e7ue pour les t\u00e2ches de commutation photovolta\u00efque. Consultez notre guide sur <a href=\"https:\/\/test.viox.com\/fr\/solar-combiner-box-voltage-ratings-600v-vs-1000v-vs-1500v\/\">Valeurs nominales de tension des bo\u00eetiers de raccordement solaires<\/a> pour plus de d\u00e9tails.<\/p>\n<p><strong>2. Syst\u00e8mes de stockage d'\u00e9nergie par batterie (ESS)<\/strong><br \/>\nLes bancs de batteries fonctionnent \u00e0 des tensions DC allant de 48V \u00e0 800V+. Une isolation est requise entre les modules de batterie et les onduleurs.<\/p>\n<p><strong>3. Infrastructure de recharge de VE<\/strong><br \/>\nLes chargeurs rapides DC fournissent 400-800V DC directement aux batteries des v\u00e9hicules.<\/p>\n<p><strong>4. Microgrids DC et centres de donn\u00e9es<\/strong><br \/>\nLes centres de donn\u00e9es utilisent de plus en plus la distribution 380V DC pour r\u00e9duire les pertes de conversion.<\/p>\n<p><strong>5. Distribution DC marine et ferroviaire<\/strong><br \/>\nLes navires et les trains utilisent la distribution DC (24V, 48V, 110V, 750V) depuis des d\u00e9cennies.<\/p>\n<h3>Utilisez des sectionneurs AC pour :<\/h3>\n<p><strong>1. Circuits de commande de moteur<\/strong><br \/>\nIsolation pour les moteurs \u00e0 induction AC, les syst\u00e8mes CVC et les pompes.<\/p>\n<p><strong>Distribution AC des b\u00e2timents<\/strong><br \/>\nIsolation pour les panneaux d'\u00e9clairage et les charges g\u00e9n\u00e9rales du b\u00e2timent.<\/p>\n<p><strong>Panneaux de commande AC industriels<\/strong><br \/>\nArmoires de commande de machines avec <a href=\"https:\/\/test.viox.com\/fr\/ac-contactor\/\">Contacteurs \u00e0 courant alternatif<\/a> et automates programmables (PLC).<\/p>\n<h3>La r\u00e8gle critique<\/h3>\n<p>Si la tension de votre syst\u00e8me est continue (m\u00eame 48 V CC), utilisez un sectionneur de qualit\u00e9 CC. La physique de l'arc ne se soucie pas du niveau de tension ; elle se soucie du type de forme d'onde. Un arc de 48 V CC peut toujours se maintenir et provoquer le soudage des contacts dans un interrupteur uniquement CA.<\/p>\n<figure><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-20306\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/DC-Isolator-in-Solar-PV-Application.webp\" alt=\"DC Isolator in Solar PV Application\" width=\"700\" height=\"467\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/DC-Isolator-in-Solar-PV-Application.webp 700w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/DC-Isolator-in-Solar-PV-Application-300x200.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/DC-Isolator-in-Solar-PV-Application-18x12.webp 18w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/DC-Isolator-in-Solar-PV-Application-600x400.webp 600w\" sizes=\"(max-width: 700px) 100vw, 700px\" \/><figcaption>Figure 6 : Sectionneur CC dans une application solaire photovolta\u00efque (contexte r\u00e9el). Ce bo\u00eetier de raccordement ouvert montre les sectionneurs CC, les fusibles, les barres omnibus et le c\u00e2blage des connecteurs dans un d\u00e9ploiement r\u00e9el sur le terrain.<\/figcaption><\/figure>\n<h2>Guide de s\u00e9lection : M\u00e9thode en 4 \u00e9tapes pour les sectionneurs CC<\/h2>\n<h3>\u00c9tape 1 : Calculer la tension maximale du syst\u00e8me<\/h3>\n<p>Pour <strong>Solaire photovolta\u00efque :<\/strong> Calculer la Voc de la cha\u00eene \u00e0 la temp\u00e9rature ambiante la plus basse pr\u00e9vue. La Voc augmente d'environ 0,3 \u00e0 0,4 % par \u00b0C en dessous de 25 \u00b0C.<\/p>\n<ul>\n<li>Exemple : cha\u00eene de 10 panneaux, Voc = 49 V\/panneau \u00e0 STC. \u00c0 -10 \u00b0C : 49 V \u00d7 1,14 (facteur de temp\u00e9rature) \u00d7 10 panneaux = <strong>Tension nominale minimale du sectionneur de 559 V CC<\/strong><\/li>\n<\/ul>\n<p><strong>Pro-Tip:<\/strong> Toujours sp\u00e9cifier une tension nominale du sectionneur d'au moins 20 % sup\u00e9rieure \u00e0 la tension maximale calcul\u00e9e du syst\u00e8me pour une marge de s\u00e9curit\u00e9.<\/p>\n<h3>\u00c9tape 2 : D\u00e9terminer le courant nominal<\/h3>\n<p>Pour <strong>Solaire photovolta\u00efque :<\/strong> Utiliser le courant de court-circuit de la cha\u00eene (Isc) \u00d7 facteur de s\u00e9curit\u00e9 de 1,25.<\/p>\n<h3>\u00c9tape 3 : V\u00e9rifier la cat\u00e9gorie d'utilisation<\/h3>\n<p>V\u00e9rifier la fiche technique pour la cat\u00e9gorie d'utilisation CEI 60947-3 : DC-21B pour les circuits CC g\u00e9n\u00e9raux, DC-PV2 sp\u00e9cifiquement pour la commutation CC photovolta\u00efque.<\/p>\n<h3>\u00c9tape 4 : Confirmer le pouvoir de coupure en court-circuit (le cas \u00e9ch\u00e9ant)<\/h3>\n<p>La plupart des sectionneurs sont con\u00e7us pour la commutation \u00e0 vide ou \u00e0 charge minimale. Pour la commutation r\u00e9guli\u00e8re de charge ou l'interruption de d\u00e9faut, sp\u00e9cifiez un <a href=\"https:\/\/test.viox.com\/fr\/dc-isolator-vs-dc-circuit-breaker-complete-comparison-guide\/\">Disjoncteur CC<\/a> \u00e0 la place.<\/p>\n<p><strong>Pro-Tip #5:<\/strong> Les sectionneurs CC co\u00fbtent 2 \u00e0 3 fois plus cher que les sectionneurs CA \u00e9quivalents, car ils n\u00e9cessitent des mat\u00e9riaux de contact fondamentalement diff\u00e9rents, des syst\u00e8mes de soufflage magn\u00e9tique et des chambres d'extinction d'arc profondes.<\/p>\n<h2>Foire Aux Questions<\/h2>\n<div>\n<div>\n<h3>Puis-je utiliser un isolateur CA pour les applications CC\u00a0?<\/h3>\n<div>\n<div>\n<p>Non, g\u00e9n\u00e9ralement vous ne pouvez pas. Les sectionneurs CA comptent sur le \u201c passage par z\u00e9ro \u201d du courant alternatif pour \u00e9teindre les arcs \u00e9lectriques. Le courant continu n'a pas de passage par z\u00e9ro, ce qui signifie que les arcs peuvent se maintenir ind\u00e9finiment dans un interrupteur CA, entra\u00eenant une surchauffe, un incendie et le soudage des contacts.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<div>\n<h3>Pourquoi les sectionneurs CC sont-ils plus grands que les sectionneurs CA ?<\/h3>\n<div>\n<div>\n<p>Les sectionneurs CC n\u00e9cessitent des composants internes plus grands, tels que des bobines d'extinction magn\u00e9tique et des chambres de coupure d'arc plus profondes (plaques de s\u00e9paration), pour forcer m\u00e9caniquement l'extinction de l'arc. Ils n\u00e9cessitent \u00e9galement des espaces de contact plus larges pour emp\u00eacher le r\u00e9amor\u00e7age de l'arc.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<div>\n<h3>Quelle est la diff\u00e9rence entre un sectionneur CC et un disjoncteur CC ?<\/h3>\n<div>\n<div>\n<p>Un sectionneur CC est con\u00e7u principalement pour la d\u00e9connexion de maintenance (isolation du circuit) et est g\u00e9n\u00e9ralement actionn\u00e9 hors charge. Un <a href=\"https:\/\/test.viox.com\/fr\/what-is-a-dc-circuit-breaker\/\">Disjoncteur CC<\/a> offre une protection automatique contre les surcharges et les courts-circuits et est con\u00e7u pour interrompre les courants de d\u00e9faut sous charge.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<h2>Conclusion : La physique n'est pas facultative<\/h2>\n<p>La diff\u00e9rence entre les sectionneurs CC et CA n'est pas une question de valeurs nominales, de co\u00fbt ou de pr\u00e9f\u00e9rence. C'est de la physique.<\/p>\n<p>Les sectionneurs CA reposent sur <strong>\u201c Le filet de s\u00e9curit\u00e9 du passage \u00e0 z\u00e9ro \u201d<\/strong>. Les sectionneurs CC sont confront\u00e9s \u00e0 <strong>\u201c Le probl\u00e8me de l'arc sans fin \u201d<\/strong>. L'arc se maintiendra ind\u00e9finiment \u00e0 moins que l'interrupteur ne force l'extinction par le biais de bobines de soufflage magn\u00e9tique et de goulottes d'arc profondes.<\/p>\n<p>Lorsque vous sp\u00e9cifiez un sectionneur pour une cha\u00eene solaire photovolta\u00efque ou un stockage de batterie, vous s\u00e9lectionnez un syst\u00e8me d'extinction d'arc. Utilisez le mauvais, et vous risquez un arc soutenu et un incendie. La r\u00e8gle est simple : si votre tension est continue, utilisez un sectionneur de qualit\u00e9 CC.<\/p>\n<p>La physique n'est pas n\u00e9gociable. Choisissez en cons\u00e9quence.<\/p>\n<hr \/>\n<p><strong>Besoin d'aide pour choisir des sectionneurs CC pour votre projet solaire photovolta\u00efque ou de stockage de batterie ?<\/strong> Contactez notre \u00e9quipe d'ing\u00e9nierie d'application pour obtenir des conseils techniques sur les solutions de commutation CC conformes \u00e0 la norme CEI 60947-3.<\/p>\n<\/div>\n<div class=\"simg-pop-btn\" style=\"top: 466.914px; left: 14px; display: none;\"><\/div>\n<div class=\"simg-pop-btn\" style=\"top: 466.914px; left: 14px; display: none;\"><\/div>\n<div class=\"simg-pop-btn\" style=\"top: 653.914px; left: 14px; display: none;\"><\/div>\n<div class=\"simg-pop-btn\" style=\"top: 653.914px; left: 14px; display: none;\"><\/div>","protected":false},"excerpt":{"rendered":"<p>Key Takeaways Zero-Crossing Factor: AC current naturally extinguishes arcs at zero-crossings (100-120 times\/sec), while DC current sustains arcs continuously. Design Differences: DC isolators require magnetic blow-out coils and deep arc chutes, making them physically larger and more expensive than AC versions. Voltage Derating: Using an AC isolator for DC applications results in a significant drop [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":19023,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1],"tags":[],"class_list":["post-19015","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"_links":{"self":[{"href":"https:\/\/test.viox.com\/fr\/wp-json\/wp\/v2\/posts\/19015","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/test.viox.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/test.viox.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/test.viox.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/test.viox.com\/fr\/wp-json\/wp\/v2\/comments?post=19015"}],"version-history":[{"count":3,"href":"https:\/\/test.viox.com\/fr\/wp-json\/wp\/v2\/posts\/19015\/revisions"}],"predecessor-version":[{"id":21359,"href":"https:\/\/test.viox.com\/fr\/wp-json\/wp\/v2\/posts\/19015\/revisions\/21359"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/test.viox.com\/fr\/wp-json\/wp\/v2\/media\/19023"}],"wp:attachment":[{"href":"https:\/\/test.viox.com\/fr\/wp-json\/wp\/v2\/media?parent=19015"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/test.viox.com\/fr\/wp-json\/wp\/v2\/categories?post=19015"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/test.viox.com\/fr\/wp-json\/wp\/v2\/tags?post=19015"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}