{"id":18397,"date":"2025-07-14T01:44:42","date_gmt":"2025-07-13T17:44:42","guid":{"rendered":"https:\/\/viox.com\/?p=18397"},"modified":"2025-07-14T01:44:45","modified_gmt":"2025-07-13T17:44:45","slug":"how-circuit-breaker-poles-affect-voltage-current-protection","status":"publish","type":"post","link":"https:\/\/test.viox.com\/fr\/how-circuit-breaker-poles-affect-voltage-current-protection\/","title":{"rendered":"Comment les p\u00f4les du disjoncteur affectent la protection contre la tension et le courant"},"content":{"rendered":"<div class=\"product-intro\">\n<h2>Introduction<\/h2>\n<p>Comprendre la configuration des p\u00f4les d&#039;un disjoncteur est essentiel \u00e0 la s\u00e9curit\u00e9 \u00e9lectrique et \u00e0 l&#039;efficacit\u00e9 du syst\u00e8me. Le nombre de p\u00f4les d&#039;un disjoncteur correspond au nombre de circuits qu&#039;il peut prot\u00e9ger, chaque p\u00f4le repr\u00e9sentant des interrupteurs individuels correspondant \u00e0 diff\u00e9rents fils ou phases \u00e9lectriques. Que vous travailliez sur des syst\u00e8mes \u00e9lectriques r\u00e9sidentiels, commerciaux ou industriels, le choix de la configuration des p\u00f4les a un impact direct sur la fourniture de tension, la protection du courant et la s\u00e9curit\u00e9 globale du syst\u00e8me.<\/p>\n<h2>Que sont les p\u00f4les d&#039;un disjoncteur ?<\/h2>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-18398\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/1P-4P-Circuit-Breaker-Poles.webp\" alt=\"1P-4P Circuit Breaker Poles\" width=\"800\" height=\"466\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/1P-4P-Circuit-Breaker-Poles.webp 800w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/1P-4P-Circuit-Breaker-Poles-300x175.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/1P-4P-Circuit-Breaker-Poles-768x447.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/1P-4P-Circuit-Breaker-Poles-18x10.webp 18w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/1P-4P-Circuit-Breaker-Poles-600x350.webp 600w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<p>Les p\u00f4les correspondent au nombre de circuits compl\u00e8tement distincts pouvant \u00eatre prot\u00e9g\u00e9s simultan\u00e9ment par un disjoncteur. Chaque p\u00f4le est consid\u00e9r\u00e9 comme un interrupteur individuel au sein du disjoncteur, capable d&#039;interrompre le flux \u00e9lectrique de mani\u00e8re ind\u00e9pendante tout en \u00e9tant reli\u00e9 m\u00e9caniquement aux autres p\u00f4les pour une protection coordonn\u00e9e.<\/p>\n<h3>Caract\u00e9ristiques principales des poteaux :<\/h3>\n<ul>\n<li><strong>Isolation \u00e9lectrique<\/strong>:Chaque p\u00f4le fonctionne sur des circuits s\u00e9par\u00e9s<\/li>\n<li><strong>Liaison m\u00e9canique<\/strong>:Les disjoncteurs multipolaires se d\u00e9clenchent ensemble lorsqu&#039;un p\u00f4le d\u00e9tecte un d\u00e9faut<\/li>\n<li><strong>Distribution de tension<\/strong>:Diff\u00e9rentes configurations de p\u00f4les fournissent diff\u00e9rentes sorties de tension<\/li>\n<li><strong>Champ d'application de la protection<\/strong>:Plus de p\u00f4les peuvent prot\u00e9ger des conducteurs suppl\u00e9mentaires, y compris les fils neutres<\/li>\n<\/ul>\n<h2>Disjoncteurs unipolaires (1P)<\/h2>\n<h3>Sp\u00e9cifications de tension et de courant<\/h3>\n<p>Les disjoncteurs unipolaires fournissent 120 volts, g\u00e9n\u00e9ralement de 15 \u00e0 20 amp\u00e8res, et sont dot\u00e9s d&#039;un fil de phase et d&#039;un fil neutre. Ce sont les disjoncteurs les plus courants dans les tableaux \u00e9lectriques r\u00e9sidentiels.<\/p>\n<h3>Applications et fonctionnalit\u00e9s de protection<\/h3>\n<p><strong>Id\u00e9al pour :<\/strong><\/p>\n<ul>\n<li>Circuits d&#039;\u00e9clairage r\u00e9sidentiels standard<\/li>\n<li>Prises \u00e0 usage g\u00e9n\u00e9ral<\/li>\n<li>Petits appareils \u00e9lectrom\u00e9nagers (t\u00e9l\u00e9viseurs, ordinateurs, petits outils \u00e9lectriques)<\/li>\n<li>Circuits n\u00e9cessitant une alimentation 120 V<\/li>\n<\/ul>\n<p><strong>Caract\u00e9ristiques de protection :<\/strong><\/p>\n<ul>\n<li>Prot\u00e8ge uniquement le conducteur chaud<\/li>\n<li>En cas de surcharge d&#039;un disjoncteur unipolaire, seul le disjoncteur concern\u00e9 se d\u00e9clenchera<\/li>\n<li>L&#039;option la plus \u00e9conome en \u00e9nergie pour les applications \u00e0 faible consommation<\/li>\n<li>Occupe un emplacement dans le panneau \u00e9lectrique<\/li>\n<\/ul>\n<h3>Configuration De C\u00e2blage<\/h3>\n<p>Les disjoncteurs unipolaires sont c\u00e2bl\u00e9s avec un fil chaud et un fil neutre, ce qui les rend simples \u00e0 installer et \u00e0 entretenir pour les circuits \u00e9lectriques de base.<\/p>\n<h2>Disjoncteurs bipolaires (2P)<\/h2>\n<h3>Sp\u00e9cifications de tension et de courant<\/h3>\n<p>Les disjoncteurs bipolaires fournissent 240 volts et 20 \u00e0 60 amp\u00e8res et poss\u00e8dent deux fils conducteurs qui partagent un fil neutre. Ces disjoncteurs sont essentiels pour les applications r\u00e9sidentielles et commerciales de forte puissance.<\/p>\n<h3>Applications et fonctionnalit\u00e9s de protection<\/h3>\n<p><strong>Id\u00e9al pour :<\/strong><\/p>\n<ul>\n<li>cuisini\u00e8res et fours \u00e9lectriques<\/li>\n<li>Syst\u00e8mes de climatisation centraux<\/li>\n<li>Chauffe-eau \u00e9lectriques<\/li>\n<li>S\u00e8che-linge<\/li>\n<li>Bains \u00e0 remous et spas<\/li>\n<li>Applications de gros moteurs<\/li>\n<\/ul>\n<p><strong>Caract\u00e9ristiques de protection :<\/strong><\/p>\n<ul>\n<li>S&#039;il y a un court-circuit sur l&#039;un des fils sous tension des p\u00f4les, les deux se d\u00e9clenchent<\/li>\n<li>Assure la d\u00e9connexion simultan\u00e9e des deux conducteurs sous tension<\/li>\n<li>Occupe deux emplacements dans le bo\u00eetier de disjoncteurs avec un interrupteur \u00e0 bascule deux fois plus long<\/li>\n<\/ul>\n<h3>Configuration De C\u00e2blage<\/h3>\n<p>Les disjoncteurs bipolaires sont c\u00e2bl\u00e9s avec deux fils chauds connect\u00e9s par un seul fil neutre, permettant un fonctionnement \u00e0 240 V en utilisant les deux branches du service \u00e9lectrique r\u00e9sidentiel.<\/p>\n<h2>Disjoncteurs tripolaires (3P)<\/h2>\n<h3>Applications de tension et de courant<\/h3>\n<p>Les disjoncteurs tripolaires sont principalement utilis\u00e9s dans les syst\u00e8mes \u00e9lectriques triphas\u00e9s courants dans les environnements commerciaux et industriels. Un disjoncteur tripolaire est principalement utilis\u00e9 dans les syst\u00e8mes \u00e9lectriques triphas\u00e9s, courants dans les grands b\u00e2timents et les applications industrielles.<\/p>\n<h3>Les Fonctions De Protection De<\/h3>\n<p><strong>Principaux avantages :<\/strong><\/p>\n<ul>\n<li>Prot\u00e8ge les trois phases simultan\u00e9ment<\/li>\n<li>Peut interrompre le circuit dans les trois phases simultan\u00e9ment, offrant une protection compl\u00e8te contre les surcharges et les courts-circuits<\/li>\n<li>Distribution d&#039;\u00e9nergie plus efficace pour les moteurs et les gros \u00e9quipements<\/li>\n<li>R\u00e9duit l&#039;espace du panneau \u00e9lectrique par rapport \u00e0 trois disjoncteurs unipolaires s\u00e9par\u00e9s<\/li>\n<\/ul>\n<h3>Quand utiliser les disjoncteurs 3P<\/h3>\n<p>Les disjoncteurs miniatures TP sont utilis\u00e9s dans les syst\u00e8mes triphas\u00e9s \u00e0 4 fils et sont le type le plus courant dans les r\u00e9seaux triphas\u00e9s ordinaires. Ils sont id\u00e9aux pour\u00a0:<\/p>\n<ul>\n<li>Moteurs triphas\u00e9s<\/li>\n<li>Machines industrielles<\/li>\n<li>Syst\u00e8mes CVC commerciaux<\/li>\n<li>Panneaux de distribution dans les b\u00e2timents commerciaux<\/li>\n<\/ul>\n<h2>Disjoncteurs t\u00e9trapolaires (4P)<\/h2>\n<h3>Fonctionnalit\u00e9s de protection am\u00e9lior\u00e9es<\/h3>\n<p>Un disjoncteur t\u00e9trapolaire offre des fonctionnalit\u00e9s similaires \u00e0 celles d&#039;un disjoncteur tripolaire, avec un p\u00f4le suppl\u00e9mentaire pour la protection de la ligne neutre. Cette protection suppl\u00e9mentaire est cruciale dans certains sc\u00e9narios \u00e9lectriques.<\/p>\n<h3>Applications critiques<\/h3>\n<p><strong>Quand les disjoncteurs 4P sont essentiels\u00a0:<\/strong><\/p>\n<p><strong>Syst\u00e8mes de charge d\u00e9s\u00e9quilibr\u00e9e :<\/strong><\/p>\n<p>Dans les syst\u00e8mes avec des charges d\u00e9s\u00e9quilibr\u00e9es, o\u00f9 la charge sur une ou plusieurs phases est significativement diff\u00e9rente des autres, une condition de d\u00e9faut peut provoquer le passage du courant \u00e0 travers le fil neutre.<\/p>\n<p><strong>Protection contre les courants harmoniques :<\/strong><\/p>\n<p>Certains types d\u2019\u00e9quipements, tels que les ordinateurs et les \u00e9clairages \u00e9co\u00e9nerg\u00e9tiques, peuvent g\u00e9n\u00e9rer des courants harmoniques qui peuvent amener le fil neutre \u00e0 transporter des niveaux de courant plus \u00e9lev\u00e9s.<\/p>\n<p><strong>Syst\u00e8mes \u00e0 double source d&#039;alimentation :<\/strong><\/p>\n<p>Lorsque nous avons une double alimentation comme dans DG et d&#039;autres sources d&#039;alimentation \u00e9lectrique, il est n\u00e9cessaire d&#039;isoler le neutre, lorsque le neutre doit \u00eatre isol\u00e9 dans le r\u00e9seau interne, un disjoncteur diff\u00e9rentiel TPN ou 4P peut \u00eatre utilis\u00e9.<\/p>\n<h3>Distinction entre TPN et 4P<\/h3>\n<p>TPN d\u00e9signe un appareil \u00e0 4 p\u00f4les dont le 4e p\u00f4le est le neutre. Pour un TPN, la protection s&#039;applique uniquement au courant traversant 3 p\u00f4les (triphas\u00e9)\u00a0; il n&#039;existe aucune protection pour le courant traversant le p\u00f4le neutre. Pour les disjoncteurs \u00e0 4 p\u00f4les, la protection s&#039;applique au courant traversant tous les p\u00f4les.<\/p>\n<h2>Diff\u00e9rences de protection de tension selon la configuration des p\u00f4les<\/h2>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-18400\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/Voltage-ratings-for-different-pole-configurations.webp\" alt=\"Voltage ratings for different pole configurations\" width=\"800\" height=\"533\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/Voltage-ratings-for-different-pole-configurations.webp 800w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/Voltage-ratings-for-different-pole-configurations-300x200.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/Voltage-ratings-for-different-pole-configurations-768x512.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/Voltage-ratings-for-different-pole-configurations-18x12.webp 18w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/Voltage-ratings-for-different-pole-configurations-600x400.webp 600w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<h3>Syst\u00e8mes monophas\u00e9s (1P et 2P)<\/h3>\n<ul>\n<li><strong>Protection 120 V<\/strong>:Les disjoncteurs unipolaires prot\u00e8gent les circuits individuels de 120 V<\/li>\n<li><strong>Protection 240 V<\/strong>:Les disjoncteurs bipolaires assurent la protection des charges de 240 V en prot\u00e9geant les deux conducteurs chauds<\/li>\n<\/ul>\n<h3>Syst\u00e8mes triphas\u00e9s (3P et 4P)<\/h3>\n<ul>\n<li><strong>Protection de phase<\/strong>:Les disjoncteurs tripolaires prot\u00e8gent les conducteurs triphas\u00e9s<\/li>\n<li><strong>Protection compl\u00e8te du syst\u00e8me<\/strong>:Les disjoncteurs \u00e0 quatre p\u00f4les ajoutent une protection neutre pour une s\u00e9curit\u00e9 compl\u00e8te du syst\u00e8me<\/li>\n<\/ul>\n<h2>Capacit\u00e9s de protection actuelles<\/h2>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-18401\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/Maximum-current-ratings-for-different-pole-configurations.webp\" alt=\"Maximum current ratings for different pole configurations\" width=\"800\" height=\"533\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/Maximum-current-ratings-for-different-pole-configurations.webp 800w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/Maximum-current-ratings-for-different-pole-configurations-300x200.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/Maximum-current-ratings-for-different-pole-configurations-768x512.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/Maximum-current-ratings-for-different-pole-configurations-18x12.webp 18w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/07\/Maximum-current-ratings-for-different-pole-configurations-600x400.webp 600w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<h3>Coordination et s\u00e9lectivit\u00e9<\/h3>\n<p>Les disjoncteurs multipolaires sont isol\u00e9s \u00e9lectriquement, mais li\u00e9s m\u00e9caniquement, con\u00e7us avec une liaison de \u00ab d\u00e9clenchement commun \u00bb qui garantit que si un p\u00f4le se d\u00e9clenche dans le disjoncteur, les autres p\u00f4les du disjoncteur se d\u00e9clencheront simultan\u00e9ment.<\/p>\n<h3>Diff\u00e9rences de philosophie de protection<\/h3>\n<ul>\n<li><strong>Unipolaire\/Bipolaire<\/strong>: Se concentre sur la protection des circuits individuels<\/li>\n<li><strong>tripolaire<\/strong>: Met l&#039;accent sur la protection triphas\u00e9e \u00e9quilibr\u00e9e<\/li>\n<li><strong>Quatre p\u00f4les<\/strong>: Fournit une protection compl\u00e8te, y compris la protection contre les d\u00e9fauts de neutre<\/li>\n<\/ul>\n<h2>Consid\u00e9rations de s\u00e9curit\u00e9 et exigences du code<\/h2>\n<h3>Protection contre les d\u00e9fauts \u00e0 la terre<\/h3>\n<p>Si une protection contre les d\u00e9fauts \u00e0 la terre sans restriction est install\u00e9e sur le neutre du transformateur, le disjoncteur de section de bus doit avoir 4 p\u00f4les et, de pr\u00e9f\u00e9rence, les disjoncteurs d&#039;arriv\u00e9e doivent \u00e9galement avoir 4 p\u00f4les.<\/p>\n<h3>S\u00e9curit\u00e9 du fil neutre<\/h3>\n<p>Normalement, la coupure du neutre est interdite, quelles que soient les conditions (sauf applications particuli\u00e8res), pour des raisons de s\u00e9curit\u00e9 humaine et mat\u00e9rielle. Cependant, certaines applications n\u00e9cessitent une coupure du neutre pour une isolation compl\u00e8te.<\/p>\n<h3>M\u00e9canismes de d\u00e9clenchement sans d\u00e9clenchement<\/h3>\n<p>Tous les disjoncteurs sont con\u00e7us avec un m\u00e9canisme de d\u00e9clenchement interne, une fonction de s\u00e9curit\u00e9 rendant impossible le maintien manuel des contacts ferm\u00e9s en cas de surintensit\u00e9 ou de d\u00e9faut.<\/p>\n<h2>Choisir la bonne configuration de poteau<\/h2>\n<h3>Matrice de d\u00e9cision<\/h3>\n<p><strong>Utiliser un p\u00f4le unique lorsque :<\/strong><\/p>\n<ul>\n<li>Circuits 120 V requis<\/li>\n<li>Protection individuelle des circuits n\u00e9cessaire<\/li>\n<li>\u00c9clairage r\u00e9sidentiel et petits \u00e9lectrom\u00e9nagers<\/li>\n<li>La rentabilit\u00e9 est une priorit\u00e9<\/li>\n<\/ul>\n<p><strong>Utiliser le bipolaire lorsque :<\/strong><\/p>\n<ul>\n<li>Fonctionnement 240 V requis<\/li>\n<li>Appareils \u00e9lectrom\u00e9nagers de grande puissance<\/li>\n<li>N\u00e9cessite la d\u00e9connexion simultan\u00e9e des deux fils sous tension<\/li>\n<\/ul>\n<p><strong>Utiliser un tripolaire lorsque :<\/strong><\/p>\n<ul>\n<li>Fonctionnement du syst\u00e8me triphas\u00e9<\/li>\n<li>Applications \u00e0 charge \u00e9quilibr\u00e9e<\/li>\n<li>Installations commerciales\/industrielles standard<\/li>\n<li>Le neutre reste sur le bus commun<\/li>\n<\/ul>\n<p><strong>Utiliser un c\u00e2ble \u00e0 quatre p\u00f4les lorsque :<\/strong><\/p>\n<ul>\n<li>Charges triphas\u00e9es d\u00e9s\u00e9quilibr\u00e9es pr\u00e9sentes<\/li>\n<li>Courants harmoniques attendus<\/li>\n<li>Configurations \u00e0 double source d&#039;alimentation<\/li>\n<li>Isolation \u00e9lectrique compl\u00e8te requise<\/li>\n<li>Une protection des \u00e9quipements sensibles est n\u00e9cessaire<\/li>\n<\/ul>\n<h2>L&#039;Installation et la Maintenance des Meilleures Pratiques<\/h2>\n<h3>Exigences d&#039;espace du panneau<\/h3>\n<ul>\n<li>Unipolaire : 1 emplacement pour panneau<\/li>\n<li>Bipolaire : 2 emplacements pour panneaux<\/li>\n<li>Tripolaire : 3 emplacements pour panneaux<\/li>\n<li>Quatre p\u00f4les : 4 emplacements pour panneaux<\/li>\n<\/ul>\n<h3>Recommandations d&#039;installation professionnelle<\/h3>\n<p>Une \u00e9valuation du syst\u00e8me doit \u00eatre requise pour d\u00e9cider si des disjoncteurs tripolaires avec liaison neutre peuvent \u00eatre utilis\u00e9s ou si des disjoncteurs t\u00e9trapolaires sont n\u00e9cessaires.<\/p>\n<h3>La Conformit\u00e9 Au Code<\/h3>\n<p>Consultez toujours les codes et normes \u00e9lectriques locaux lors du choix des configurations de p\u00f4les de disjoncteur. Une \u00e9valuation professionnelle garantit une coordination ad\u00e9quate de la protection et la s\u00e9curit\u00e9 du syst\u00e8me.<\/p>\n<h2>Conclusion<\/h2>\n<p>Le nombre de p\u00f4les des disjoncteurs a un impact significatif sur la tension d\u00e9livr\u00e9e et la protection du courant. Les disjoncteurs unipolaires et bipolaires r\u00e9pondent efficacement aux besoins r\u00e9sidentiels, tandis que les configurations tripolaires et t\u00e9trapolaires offrent la protection compl\u00e8te requise pour les applications commerciales et industrielles.<\/p>\n<p>Points cl\u00e9s \u00e0 retenir pour les professionnels de l\u2019\u00e9lectricit\u00e9 :<\/p>\n<ul>\n<li>Adaptez la configuration des p\u00f4les aux exigences de tension du syst\u00e8me<\/li>\n<li>Tenez compte des caract\u00e9ristiques de charge et de l&#039;\u00e9quilibre lors du choix entre 3P et 4P<\/li>\n<li>\u00c9valuer le potentiel de courant neutre dans les environnements riches en harmoniques<\/li>\n<li>Assurer une bonne coordination avec les dispositifs de protection en amont et en aval<\/li>\n<\/ul>\n<p>La compr\u00e9hension de ces diff\u00e9rences permet de prendre des d\u00e9cisions \u00e9clair\u00e9es qui am\u00e9liorent la s\u00e9curit\u00e9, la fiabilit\u00e9 et la conformit\u00e9 aux codes du syst\u00e8me \u00e9lectrique dans tous les types d\u2019installation.<\/p>\n<h2>Li\u00e9es<\/h2>\n<p><a href=\"https:\/\/test.viox.com\/fr\/how-to-choose-the-right-miniature-circuit-breaker\/\">Comment choisir le bon disjoncteur miniature : Guide technique complet<\/a><\/p>\n<p><a href=\"https:\/\/test.viox.com\/fr\/2-pole-vs-3-pole-breaker\/\">Disjoncteur bipolaire ou tripolaire\u00a0: guide complet<\/a><\/p>\n<p><a href=\"https:\/\/test.viox.com\/fr\/how-to-replace-a-circuit-breaker\/\">Comment remplacer un disjoncteur<\/a><\/p>\n<p><a href=\"https:\/\/test.viox.com\/fr\/what-is-a-dc-circuit-breaker\/\">Qu&#039;est-ce qu&#039;un disjoncteur CC<\/a><\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Introduction Understanding circuit breaker pole configurations is crucial for electrical safety and system efficiency. The number of poles in a circuit breaker refers to the number of circuits the device can protect, with each pole representing individual switches within the breaker that correspond to different wires or phases of electricity. Whether you&#8217;re working with residential, [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":18402,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1],"tags":[],"class_list":["post-18397","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"_links":{"self":[{"href":"https:\/\/test.viox.com\/fr\/wp-json\/wp\/v2\/posts\/18397","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/test.viox.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/test.viox.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/test.viox.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/test.viox.com\/fr\/wp-json\/wp\/v2\/comments?post=18397"}],"version-history":[{"count":0,"href":"https:\/\/test.viox.com\/fr\/wp-json\/wp\/v2\/posts\/18397\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/test.viox.com\/fr\/wp-json\/wp\/v2\/media\/18402"}],"wp:attachment":[{"href":"https:\/\/test.viox.com\/fr\/wp-json\/wp\/v2\/media?parent=18397"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/test.viox.com\/fr\/wp-json\/wp\/v2\/categories?post=18397"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/test.viox.com\/fr\/wp-json\/wp\/v2\/tags?post=18397"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}