{"id":5506,"date":"2024-09-12T20:58:28","date_gmt":"2024-09-12T12:58:28","guid":{"rendered":"https:\/\/viox.com\/?post_type=product&#038;p=5506"},"modified":"2024-09-12T21:01:32","modified_gmt":"2024-09-12T13:01:32","slug":"viox-vsp1-c40pv-3s-1500vd4-pluggable-multi-pole-spd","status":"publish","type":"product","link":"https:\/\/test.viox.com\/fa\/product\/viox-vsp1-c40pv-3s-1500vd4-pluggable-multi-pole-spd\/","title":{"rendered":"VIOX VSP1-C40PV\/3(S) 1500V(D4) \u0686\u0646\u062f \u0642\u0637\u0628\u06cc \u0642\u0627\u0628\u0644 \u0627\u062a\u0635\u0627\u0644 SPD"},"content":{"rendered":"<div class=\"product-intro\">\n<h2>VIOX VSP1-C40PV\/3(S) 1500V(D4) Pluggable Multi-Pole SPD<\/h2>\n<h2>Overview<\/h2>\n<p>The VIOX VSP1-C40PV\/3(S) 1500V(D4) is a high-performance Pluggable Multi-Pole Surge Protective Device (SPD) designed for use in sub-distribution boards. This versatile device offers robust protection for (DC+) &#8211; PE and (DC-) &#8211; PE modes, making it an ideal solution for high-voltage photovoltaic systems and other DC applications requiring multi-pole protection up to 1500V.<\/p>\n<h2>Key Features<\/h2>\n<ul>\n<li>Class I, Class II, Type 1, Type 2 device<\/li>\n<li>Location of Use: Sub-Distribution Boards<\/li>\n<li>Mode of Protection: (DC+) &#8211; PE, (DC-) &#8211; PE<\/li>\n<li>Surge Ratings: In = 20 kA (8\/20 \u03bcs)<\/li>\n<li>IEC\/EN\/UL Category: Class I+II \/ Type 1+2<\/li>\n<li>Protective Elements: High Energy MOV<\/li>\n<li>Housing: Pluggable Design<a href=\"https:\/\/test.viox.com\/?attachment_id=5510\" rel=\"attachment wp-att-5510\"><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-5510\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VSP1-C40PV_3S-1500VD4-Pluggable-Multi-Pole-SPD02.webp\" alt=\"\" width=\"474\" height=\"446\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VSP1-C40PV_3S-1500VD4-Pluggable-Multi-Pole-SPD02.webp 474w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VSP1-C40PV_3S-1500VD4-Pluggable-Multi-Pole-SPD02-300x282.webp 300w\" sizes=\"(max-width: 474px) 100vw, 474px\" \/><\/a><\/li>\n<li>Compliance: IEC 61643-31:2018, EN 50539-11:2013+A1:2014<\/li>\n<\/ul>\n<h2>Technical Specifications<\/h2>\n<table border=\"1\" cellpadding=\"5\">\n<tbody>\n<tr>\n<th>IEC Electrical<\/th>\n<th>1500<\/th>\n<\/tr>\n<tr>\n<td>Nominal AC Voltage<\/td>\n<td>1500 V<\/td>\n<\/tr>\n<tr>\n<td>Maximum Continuous Operating Voltage (DC)<\/td>\n<td>1500 V<\/td>\n<\/tr>\n<tr>\n<td>Nominal Discharge Current (8\/20 \u03bcs)<\/td>\n<td>20 kA<\/td>\n<\/tr>\n<tr>\n<td>Maximum Discharge Current (8\/20 \u03bcs)<\/td>\n<td>40 kA<\/td>\n<\/tr>\n<tr>\n<td>Impulse Discharge Current (10\/350 \u03bcs)<\/td>\n<td>6.25 kA<\/td>\n<\/tr>\n<tr>\n<td>Voltage Protection Level<\/td>\n<td>5.6 kV<\/td>\n<\/tr>\n<tr>\n<td>Response Time<\/td>\n<td>&lt; 25 ns<\/td>\n<\/tr>\n<tr>\n<td>Back-Up Fuse (max)<\/td>\n<td>125 A gL \/ gG<\/td>\n<\/tr>\n<tr>\n<td>Short-Circuit Current Rating (AC)<\/td>\n<td>25 kA \/ 50 kA<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Mechanical &amp; Environmental Specifications<\/h2>\n<ul>\n<li>Operating Temperature Range: -40\u00b0F to +158\u00b0F [-40\u00b0C to +70\u00b0C]<\/li>\n<li>Permissible Operating Humidity: 5%&#8230;95%<\/li>\n<li>Atmospheric pressure and altitude: 80k Pa &#8230; 106k Pa \/ -500 m&#8230;.2000 m<\/li>\n<li>Terminal Screw Torque: 39.9 lbf.in [4.5 Nm]<\/li>\n<li>Conductor Cross Section (max): 2 AWG (Solid, Stranded) \/ 4 AWG (Flexible)<\/li>\n<li>35 mm\u00b2 (Solid, Stranded) \/ 25 mm\u00b2(Flexible)<\/li>\n<li>Mounting: 35 mm DIN Rail, EN 60715<\/li>\n<li>Degree of Protection: IP 20 (built-in)<\/li>\n<li>Housing Material: Thermoplastic: Extinguishing Degree UL 94 V-0<\/li>\n<li>Thermal Protection: Yes<\/li>\n<li>Operating State \/ Fault Indication: Green ok \/ Red defect<\/li>\n<\/ul>\n<h2>Additional Features<\/h2>\n<ul>\n<li>Remote Contacts (RC): Optional<\/li>\n<li>RC Switching Capacity: AC: 250V \/ 0.5 A; DC: 250V \/ 0.1 A;125V \/ 0.2 A;75V \/ 0.5 A<\/li>\n<li>RC Conductor Cross Section (max): 16 AWG (Solid) \/ 1.5 mm\u00b2(Solid)<\/li>\n<\/ul>\n<h2>Internal Configuration<\/h2>\n<p><a href=\"https:\/\/test.viox.com\/?attachment_id=5509\" rel=\"attachment wp-att-5509\"><img decoding=\"async\" class=\"alignnone size-full wp-image-5509\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VSP1-C40PV_3S-1500VD4-Pluggable-Multi-Pole-SPD04.webp\" alt=\"\" width=\"480\" height=\"416\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VSP1-C40PV_3S-1500VD4-Pluggable-Multi-Pole-SPD04.webp 480w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VSP1-C40PV_3S-1500VD4-Pluggable-Multi-Pole-SPD04-300x260.webp 300w\" sizes=\"(max-width: 480px) 100vw, 480px\" \/><\/a><\/p>\n<h2>Dimension<\/h2>\n<p><a href=\"https:\/\/test.viox.com\/?attachment_id=5508\" rel=\"attachment wp-att-5508\"><img decoding=\"async\" class=\"alignnone size-full wp-image-5508\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VSP1-C40PV_3S-1500VD4-Pluggable-Multi-Pole-SPD03.webp\" alt=\"\" width=\"708\" height=\"354\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VSP1-C40PV_3S-1500VD4-Pluggable-Multi-Pole-SPD03.webp 708w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VSP1-C40PV_3S-1500VD4-Pluggable-Multi-Pole-SPD03-300x150.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VSP1-C40PV_3S-1500VD4-Pluggable-Multi-Pole-SPD03-600x300.webp 600w\" sizes=\"(max-width: 708px) 100vw, 708px\" \/><\/a><\/p>\n<h2>Connection Diagram<\/h2>\n<p>[Image placeholder for Connection Diagram]<\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<div class=\"msg-content MuiBox-root css-0\">\n<div class=\"break-words\">\n<p>SPD \u0686\u0646\u062f \u0642\u0637\u0628\u06cc \u0642\u0627\u0628\u0644 \u0627\u062a\u0635\u0627\u0644 VIOX VSP1-C40PV\/3(S) 1500V(D4) \u0645\u062d\u0627\u0641\u0638\u062a \u062f\u0631 \u0628\u0631\u0627\u0628\u0631 \u0646\u0648\u0633\u0627\u0646\u0627\u062a \u0628\u0631\u0642 \u0642\u0648\u06cc \u0631\u0627 \u0628\u0631\u0627\u06cc \u0633\u06cc\u0633\u062a\u0645\u200c\u0647\u0627\u06cc \u0641\u062a\u0648\u0648\u0644\u062a\u0627\u0626\u06cc\u06a9 \u0648\u0644\u062a\u0627\u0698 \u0628\u0627\u0644\u0627 \u062a\u0627 1500 \u0648\u0644\u062a DC \u0627\u0631\u0627\u0626\u0647 \u0645\u06cc\u200c\u062f\u0647\u062f. \u0627\u06cc\u0646 \u062f\u0633\u062a\u06af\u0627\u0647 \u06a9\u0644\u0627\u0633 I+II\/\u0646\u0648\u0639 1+2 \u062d\u0627\u0644\u062a\u200c\u0647\u0627\u06cc (DC+) \u2013 PE \u0648 (DC-) \u2013 PE \u0631\u0627 \u0628\u0627 \u062c\u0631\u06cc\u0627\u0646 \u062a\u062e\u0644\u06cc\u0647 \u0627\u0633\u0645\u06cc 20kA \u0648 \u062d\u062f\u0627\u06a9\u062b\u0631 40kA \u0645\u062d\u0627\u0641\u0638\u062a \u0645\u06cc\u200c\u06a9\u0646\u062f. \u0627\u06cc\u0646 \u062f\u0633\u062a\u06af\u0627\u0647 \u0628\u0627 \u062f\u0627\u0634\u062a\u0646 \u0639\u0646\u0627\u0635\u0631 MOV \u067e\u0631\u0627\u0646\u0631\u0698\u06cc\u060c \u0633\u0637\u062d \u0645\u062d\u0627\u0641\u0638\u062a \u0648\u0644\u062a\u0627\u0698 5.6kV \u0631\u0627 \u0628\u0627 \u0632\u0645\u0627\u0646 \u067e\u0627\u0633\u062e \u06a9\u0645\u062a\u0631 \u0627\u0632 25ns \u0641\u0631\u0627\u0647\u0645 \u0645\u06cc\u200c\u06a9\u0646\u062f. \u0637\u0631\u0627\u062d\u06cc \u0642\u0627\u0628\u0644 \u0627\u062a\u0635\u0627\u0644\u060c \u0646\u0635\u0628 \u0622\u0633\u0627\u0646 \u0631\u0648\u06cc \u0631\u06cc\u0644\u200c\u0647\u0627\u06cc DIN 35 \u0645\u06cc\u0644\u06cc\u200c\u0645\u062a\u0631\u06cc \u0631\u0627 \u062a\u0636\u0645\u06cc\u0646 \u0645\u06cc\u200c\u06a9\u0646\u062f. \u0645\u0637\u0627\u0628\u0642 \u0628\u0627 IEC 61643-31:2018 \u0648 EN 50539-11:2013+A1:2014\u060c \u0634\u0627\u0645\u0644 \u062d\u0641\u0627\u0638\u062a IP20\u060c \u0645\u062d\u0627\u0641\u0638 \u062d\u0631\u0627\u0631\u062a\u06cc \u0648 \u06a9\u0646\u062a\u0627\u06a9\u062a\u200c\u0647\u0627\u06cc \u0627\u0632 \u0631\u0627\u0647 \u062f\u0648\u0631 \u0627\u062e\u062a\u06cc\u0627\u0631\u06cc \u0627\u0633\u062a. \u0627\u06cc\u0646 SPD \u0686\u0646\u062f \u0642\u0637\u0628\u06cc \u0647\u0645\u0647 \u06a9\u0627\u0631\u0647\u060c \u0642\u0627\u0628\u0644\u06cc\u062a \u0627\u0637\u0645\u06cc\u0646\u0627\u0646 \u0648 \u0639\u0645\u0644\u06a9\u0631\u062f \u0631\u0627 \u0628\u0631\u0627\u06cc \u0645\u062d\u0627\u0641\u0638\u062a \u067e\u06cc\u0634\u0631\u0641\u062a\u0647 \u0627\u0632 \u0633\u06cc\u0633\u062a\u0645 \u0642\u062f\u0631\u062a \u062f\u0631 \u06a9\u0627\u0631\u0628\u0631\u062f\u0647\u0627\u06cc DC \u0628\u0627 \u0648\u0644\u062a\u0627\u0698 \u0641\u0648\u0642 \u0628\u0627\u0644\u0627 \u0648 \u0641\u062a\u0648\u0648\u0644\u062a\u0627\u0626\u06cc\u06a9 \u062a\u0631\u06a9\u06cc\u0628 \u0645\u06cc\u200c\u06a9\u0646\u062f.<\/p>\n<\/div>\n<\/div>","protected":false},"featured_media":5507,"comment_status":"closed","ping_status":"closed","template":"","meta":{"inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[],"product_cat":[116,127],"product_tag":[],"class_list":{"0":"post-5506","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-low-voltage-protection-devices","7":"product_cat-surge-protector","8":"desktop-align-left","9":"tablet-align-left","10":"mobile-align-left","12":"first","13":"instock","14":"shipping-taxable","15":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/test.viox.com\/fa\/wp-json\/wp\/v2\/product\/5506","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/test.viox.com\/fa\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/test.viox.com\/fa\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/test.viox.com\/fa\/wp-json\/wp\/v2\/comments?post=5506"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/test.viox.com\/fa\/wp-json\/wp\/v2\/media\/5507"}],"wp:attachment":[{"href":"https:\/\/test.viox.com\/fa\/wp-json\/wp\/v2\/media?parent=5506"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/test.viox.com\/fa\/wp-json\/wp\/v2\/product_brand?post=5506"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/test.viox.com\/fa\/wp-json\/wp\/v2\/product_cat?post=5506"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/test.viox.com\/fa\/wp-json\/wp\/v2\/product_tag?post=5506"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}