{"id":2601,"date":"2024-06-13T19:15:08","date_gmt":"2024-06-13T11:15:08","guid":{"rendered":"https:\/\/viox.com\/?post_type=product&#038;p=2601"},"modified":"2024-06-13T19:27:50","modified_gmt":"2024-06-13T11:27:50","slug":"15mm-capacitive-proximity-sensor-ki0206","status":"publish","type":"product","link":"https:\/\/test.viox.com\/es\/producto\/15mm-capacitive-proximity-sensor-ki0206\/","title":{"rendered":"Sensor de proximidad capacitivo de 15 mm KI0206"},"content":{"rendered":"<table style=\"font-size: 16px; font-style: normal;\">\n<tbody>\n<tr class=\"firstRow\">\n<td colspan=\"2\">Modelo<\/td>\n<td>KI0206<\/td>\n<td>KI0207<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\">Producto<br \/>\ncaracter\u00edsticas<\/td>\n<td>Funci\u00f3n de salida<\/td>\n<td>Nominalmente abierto<\/td>\n<td>Normalmente cerrado<\/td>\n<\/tr>\n<tr>\n<td>Alcance de detecci\u00f3n (mm)<\/td>\n<td>3~15<\/td>\n<td>3~15<\/td>\n<\/tr>\n<tr>\n<td>Vivienda<\/td>\n<td>Tipo roscado<\/td>\n<td>Tipo roscado<\/td>\n<\/tr>\n<tr>\n<td>Dimensiones (mm)<\/td>\n<td>M30\u00d71.5<\/td>\n<td>M30\u00d71.5<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">El\u00e9ctrico<br \/>\nfecha<\/td>\n<td>Tensi\u00f3n de funcionamiento (V)<\/td>\n<td>20~250 CA\/CC<\/td>\n<td>20~250 CA\/CC<\/td>\n<\/tr>\n<tr>\n<td>Clase de protecci\u00f3n<\/td>\n<td>\u2161<\/td>\n<td>\u2161<\/td>\n<\/tr>\n<tr>\n<td>Protecci\u00f3n contra polaridad inversa<\/td>\n<td>no<\/td>\n<td>no<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"12\">Salida<\/td>\n<td>Funci\u00f3n de salida<\/td>\n<td>Normalmente abierto<\/td>\n<td>Normalmente cerrado<\/td>\n<\/tr>\n<tr>\n<td>M\u00e1x. ca\u00edda de tensi\u00f3n de conmutaci\u00f3n<br \/>\nsalida DC(V)<\/td>\n<td>8<\/td>\n<td>8<\/td>\n<\/tr>\n<tr>\n<td>M\u00e1x. ca\u00edda de tensi\u00f3n de conmutaci\u00f3n<br \/>\nsalida AC(V)<\/td>\n<td>10<\/td>\n<td>10<\/td>\n<\/tr>\n<tr>\n<td>Corriente de carga m\u00ednima (mA)<\/td>\n<td>5<\/td>\n<td>5<\/td>\n<\/tr>\n<tr>\n<td>Corriente de fuga m\u00e1x. (mA)<\/td>\n<td>2,5(250V AV) \/ 1,7(110V AC) \/ 1,5(24V DC)<\/td>\n<td>2,5(250 V AC)\/1,7(110 V AC)\/1,5(24 V DC)<\/td>\n<\/tr>\n<tr>\n<td>Corriente nominal permanente de<br \/>\nSalida de conmutaci\u00f3n AC(mA)<\/td>\n<td>200\uff1b\uff08250\uff08...50\u2103))<\/td>\n<td>200\uff1b\uff08250\uff08...50\u2103))<\/td>\n<\/tr>\n<tr>\n<td>Corriente nominal permanente de<br \/>\nSalida de conmutaci\u00f3n DC(mA)<\/td>\n<td>200\uff1b\uff08250\uff08...51\u2103))<\/td>\n<td>200\uff1b\uff08250\uff08...50\u2103))<\/td>\n<\/tr>\n<tr>\n<td>Corriente nominal de corta duraci\u00f3n de<br \/>\nSalida de conmutaci\u00f3n (mA)<\/td>\n<td>1500;(20ms\/ 0,5Hz)<\/td>\n<td>1500;(20ms\/ 0,5Hz)<\/td>\n<\/tr>\n<tr>\n<td>Frecuencia de conmutaci\u00f3n AC(Hz)<\/td>\n<td>25<\/td>\n<td>25<\/td>\n<\/tr>\n<tr>\n<td>Frecuencia de conmutaci\u00f3n DC(Hz)<\/td>\n<td>50<\/td>\n<td>50<\/td>\n<\/tr>\n<tr>\n<td>A prueba de cortocircuitos<\/td>\n<td>no<\/td>\n<td>no<\/td>\n<\/tr>\n<tr>\n<td>Protecci\u00f3n contra sobrecargas<\/td>\n<td>no<\/td>\n<td>no<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\">Supervisi\u00f3n<br \/>\ngama<\/td>\n<td>Alcance de detecci\u00f3n (mm)<\/td>\n<td>3~15<\/td>\n<td>3~15<\/td>\n<\/tr>\n<tr>\n<td>Rango de detecci\u00f3n ajustable<\/td>\n<td>s\u00ed<\/td>\n<td>s\u00ed<\/td>\n<\/tr>\n<tr>\n<td>Rango de ajuste de f\u00e1brica (mm)<\/td>\n<td>15<\/td>\n<td>15<\/td>\n<\/tr>\n<tr>\n<td>Alcance real Sr(mm)<\/td>\n<td>15\u00b110\uff05<\/td>\n<td>15\u00b110\uff05<\/td>\n<\/tr>\n<tr>\n<td>Distancia de funcionamiento (mm)<\/td>\n<td>0~12.1<\/td>\n<td>0~12.1<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">Precisi\u00f3n\/desviaciones<\/td>\n<td>Factor de correcci\u00f3n<\/td>\n<td>vidrio:0,4 \/agua:1 \/cer\u00e1mica:0,2 \/PVC:0,2<\/td>\n<td>vidrio:0,4 \/agua:1 \/cer\u00e1mica:0,2 \/PVC:0,2<\/td>\n<\/tr>\n<tr>\n<td>Hist\u00e9resis (\uff05 de Sr)<\/td>\n<td>1~15<\/td>\n<td>1~15<\/td>\n<\/tr>\n<tr>\n<td>Deriva del punto de conmutaci\u00f3n (\uff05 de Sr)<\/td>\n<td>-15-15<\/td>\n<td>-15~15<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">Funcionamiento<br \/>\ncondiciones<\/td>\n<td>Temperatura ambiente(\u2103)<\/td>\n<td>-25-70<\/td>\n<td>-25~70<\/td>\n<\/tr>\n<tr>\n<td>Protecci\u00f3n<\/td>\n<td>IP65<\/td>\n<td>IP65<\/td>\n<\/tr>\n<tr>\n<td>Aumento de la inmunidad<\/td>\n<td>s\u00ed;(Mayor inmunidad a las interferencias de radiofrecuencia conducidas<\/td>\n<td>s\u00ed;(Aumento de la inmunidad a las<br \/>\ninterferencias de radiofrecuencia<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Pruebas\/aprobaciones<\/td>\n<td>EMC<\/td>\n<td>EN 60947-5-2<\/td>\n<td>EN 60947-5-2<\/td>\n<\/tr>\n<tr>\n<td>MTTF(a\u00f1os)<\/td>\n<td>302<\/td>\n<td>302<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"6\">Datos mec\u00e1nicos<\/td>\n<td>Peso (g)<\/td>\n<td>126<\/td>\n<td>126.5<\/td>\n<\/tr>\n<tr>\n<td>Vivienda<\/td>\n<td>Tipo roscado<\/td>\n<td>Tipo roscado<\/td>\n<\/tr>\n<tr>\n<td>Se puede montar en<\/td>\n<td>no enrasable<\/td>\n<td>no enrasable<\/td>\n<\/tr>\n<tr>\n<td>Dimensiones (mm)<\/td>\n<td>M30\u00d71.5<\/td>\n<td>M30\u00d71.5<\/td>\n<\/tr>\n<tr>\n<td>Designaci\u00f3n del hilo<\/td>\n<td>M30\u00d71.5<\/td>\n<td>M30\u00d71.5<\/td>\n<\/tr>\n<tr>\n<td>Material<\/td>\n<td>PBT<\/td>\n<td>PBT<\/td>\n<\/tr>\n<tr>\n<td>Mostrar<\/td>\n<td>Mostrar<\/td>\n<td>Estado de conmutaci\u00f3n 1\u00d7LED ,amarillo<\/td>\n<td>Estado de conmutaci\u00f3n 1\u00d7LED ,amarillo<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Accesorios<\/td>\n<td>tuercas de seguridad:2<\/td>\n<td>tuercas de seguridad:2<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Observaciones<\/td>\n<td>Observaciones<\/td>\n<td>Recomendaci\u00f3n:<br \/>\ncompruebe que la unidad funciona correctamente tras un cortocircuito<\/td>\n<td>Recomendaci\u00f3n:<br \/>\ncompruebe que la unidad funciona correctamente tras un cortocircuito<\/td>\n<\/tr>\n<tr>\n<td>Cantidad por envase<\/td>\n<td><\/td>\n<td>1 unidad<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Conexi\u00f3n el\u00e9ctrica<\/td>\n<td>Protecci\u00f3n necesaria<\/td>\n<td>fusible miniatura seg\u00fan IEC60127-2 hoja 1;\u22642A;acci\u00f3n r\u00e1pida<\/td>\n<td>fusible miniatura seg\u00fan IEC60127-2 hoja 1;\u22642A;acci\u00f3n r\u00e1pida<\/td>\n<\/tr>\n<tr>\n<td>Enchufe<\/td>\n<td>Cable:0,1 m,PVC;2\u00d70,5 mm\u00b2.<br \/>\nConector: 1\u00d71\/2\u2033;codificaci\u00f3n:C<\/td>\n<td>Cable:0,1 m,PVC;2\u00d70,5 mm\u00b2.<br \/>\nConector: 1\u00d71\/2\u2033;codificaci\u00f3n:C<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone wp-image-2609 size-full\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/06\/15mm-capacitive-proximity-sensor-KI0206-Dimension.webp\" alt=\"\" width=\"800\" height=\"800\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/06\/15mm-capacitive-proximity-sensor-KI0206-Dimension.webp 800w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/06\/15mm-capacitive-proximity-sensor-KI0206-Dimension-300x300.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/06\/15mm-capacitive-proximity-sensor-KI0206-Dimension-150x150.webp 150w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/06\/15mm-capacitive-proximity-sensor-KI0206-Dimension-768x768.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/06\/15mm-capacitive-proximity-sensor-KI0206-Dimension-600x600.webp 600w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/06\/15mm-capacitive-proximity-sensor-KI0206-Dimension-100x100.webp 100w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>","protected":false},"excerpt":{"rendered":"<p>Sensor de proximidad capacitivo, 15 mm de alcance no enrasado, carcasa de pl\u00e1stico de 30 mm, 2 hilos CA\/CC, salida N.A., cable de 100 mm con conector Micro AC.<\/p>","protected":false},"featured_media":2602,"comment_status":"closed","ping_status":"closed","template":"","meta":{"inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[],"product_cat":[30,77],"product_tag":[],"class_list":{"0":"post-2601","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-sensors","7":"product_cat-ultrasonic-sensors","8":"desktop-align-left","9":"tablet-align-left","10":"mobile-align-left","12":"first","13":"instock","14":"shipping-taxable","15":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/test.viox.com\/es\/wp-json\/wp\/v2\/product\/2601","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/test.viox.com\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/test.viox.com\/es\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/test.viox.com\/es\/wp-json\/wp\/v2\/comments?post=2601"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/test.viox.com\/es\/wp-json\/wp\/v2\/media\/2602"}],"wp:attachment":[{"href":"https:\/\/test.viox.com\/es\/wp-json\/wp\/v2\/media?parent=2601"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/test.viox.com\/es\/wp-json\/wp\/v2\/product_brand?post=2601"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/test.viox.com\/es\/wp-json\/wp\/v2\/product_cat?post=2601"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/test.viox.com\/es\/wp-json\/wp\/v2\/product_tag?post=2601"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}