{"id":21474,"date":"2026-01-28T18:23:42","date_gmt":"2026-01-28T10:23:42","guid":{"rendered":"https:\/\/viox.com\/?p=21474"},"modified":"2026-01-28T18:23:46","modified_gmt":"2026-01-28T10:23:46","slug":"mccb-short-time-delay-icw-rating-explained","status":"publish","type":"post","link":"https:\/\/test.viox.com\/es\/mccb-short-time-delay-icw-rating-explained\/","title":{"rendered":"\u00bfPor qu\u00e9 los MCCB ofrecen protecci\u00f3n de retardo de corta duraci\u00f3n sin una corriente nominal de resistencia de corta duraci\u00f3n (I<sub>cw<\/sub>)"},"content":{"rendered":"<div class=\"product-intro\">\n<figure style=\"text-align: center; margin: 20px 0;\"><img decoding=\"async\" style=\"max-width: 100%; height: auto;\" src=\"https:\/\/img.viox.com\/MCCB-electronic-trip-unit-in-industrial-panel-showing-400A-rating-and-current-display.webp\" alt=\"MCCB electronic trip unit in industrial panel showing 400A rating and current display - VIOX Electric\" \/><figcaption style=\"font-style: italic; color: #555; margin-top: 8px;\">Unidad de disparo electr\u00f3nico MCCB en panel industrial que muestra una clasificaci\u00f3n de 400A y visualizaci\u00f3n de corriente \u2013 VIOX Electric<\/figcaption><\/figure>\n<h2>Respuesta directa<\/h2>\n<p><strong><a href=\"https:\/\/test.viox.com\/es\/mccb\/\">Disyuntores de caja moldeada (MCCB)<\/a> puede proporcionar protecci\u00f3n de retardo de corta duraci\u00f3n sin una corriente nominal de resistencia de corta duraci\u00f3n (I<sub>cw<\/sub>) porque pertenecen a la Categor\u00eda A de la norma IEC 60947-2, donde la selectividad se logra a trav\u00e9s de la tecnolog\u00eda de limitaci\u00f3n de corriente en lugar de retardos de tiempo intencionales.<\/strong> A diferencia de los interruptores autom\u00e1ticos de bastidor abierto (ACB) de Categor\u00eda B que \u201cesperan\u201d las corrientes de falla utilizando una alta I<sub>cw<\/sub> , los MCCB utilizan la repulsi\u00f3n electromagn\u00e9tica de los contactos y la interrupci\u00f3n de arco ultrarr\u00e1pida para limitar la energ\u00eda de falla, protegi\u00e9ndose a s\u00ed mismos mientras se coordinan con los dispositivos aguas abajo a trav\u00e9s de sus caracter\u00edsticas inherentes de retardo corto (t\u00edpicamente 10-12\u00d7 I<sub>n<\/sub>) por debajo del umbral de disparo instant\u00e1neo.<\/p>\n<hr \/>\n<h2>Puntos Clave<\/h2>\n<ul>\n<li>\u2705 <strong>Categor\u00eda A vs. B<\/strong>: Los MCCB (Categor\u00eda A) carecen de I<sub>cw<\/sub> declaradas, pero poseen una capacidad inherente de resistencia de corta duraci\u00f3n por debajo de su umbral de repulsi\u00f3n de contacto (t\u00edpicamente &gt;12-14\u00d7 I<sub>n<\/sub>)<\/li>\n<li>\u2705 <strong>F\u00edsica de la limitaci\u00f3n de corriente<\/strong>: La presi\u00f3n del resorte de contacto es intencionalmente baja en los MCCB para permitir una r\u00e1pida repulsi\u00f3n electromagn\u00e9tica a altas corrientes de falla (&gt;25\u00d7 I<sub>n<\/sub>), previniendo da\u00f1os a trav\u00e9s de una interrupci\u00f3n r\u00e1pida en lugar de una resistencia prolongada<\/li>\n<li>\u2705 <strong>Realidad del retardo corto<\/strong>: Los ajustes de retardo corto de MCCB (por ejemplo, 10\u00d7 I<sub>n<\/sub>, 0.4s) solo funcionan cuando la corriente de falla se mantiene por debajo del umbral de disparo instant\u00e1neo; exceder esto desencadena una acci\u00f3n inmediata a trav\u00e9s de un disparo magn\u00e9tico o mecanismos basados en energ\u00eda<\/li>\n<li>\u2705 <strong>Limitaciones de selectividad<\/strong>: La selectividad total entre MCCB requiere tablas de coordinaci\u00f3n cuidadosas; las cascadas ACB a MCCB logran mejores resultados porque los ACB pueden retrasar verdaderamente (capacidad I<sub>cw<\/sub> = I<sub>cu<\/sub> ) mientras que los MCCB manejan las fallas aguas abajo<\/li>\n<li>\u2705 <strong>Anulaci\u00f3n de seguridad<\/strong>: Los MCCB avanzados con disparos instant\u00e1neos desactivables (por ejemplo, Schneider NSX) incorporan funciones de \u201cdisparo de energ\u00eda\u201d o \u201canulaci\u00f3n instant\u00e1nea\u201d: si la corriente de falla excede ~25\u00d7 I<sub>n<\/sub>, los mecanismos accionados por gas fuerzan el disparo inmediato independientemente de la configuraci\u00f3n<\/li>\n<\/ul>\n<hr \/>\n<h2>Comprensi\u00f3n de las categor\u00edas de selectividad IEC 60947-2<\/h2>\n<figure style=\"text-align: center; margin: 20px 0;\"><img decoding=\"async\" style=\"max-width: 100%; height: auto;\" src=\"https:\/\/img.viox.com\/Size-and-construction-comparison-between-ACB-with-Icw-rating-and-compact-MCCB-Category-A-breaker.webp\" alt=\"Size and construction comparison between ACB with Icw rating and compact MCCB Category A breaker - VIOX Electric\" \/><figcaption style=\"font-style: italic; color: #555; margin-top: 8px;\">Comparaci\u00f3n de tama\u00f1o y construcci\u00f3n entre ACB con clasificaci\u00f3n Icw e interruptor compacto MCCB Categor\u00eda A \u2013 VIOX Electric<\/figcaption><\/figure>\n<h3>Categor\u00eda B: ACB con I<sub>cw<\/sub><\/h3>\n<p>Los interruptores autom\u00e1ticos de bastidor abierto (ACB) est\u00e1n dise\u00f1ados para <strong>Categor\u00eda B<\/strong> aplicaciones donde la selectividad se logra a trav\u00e9s de retardos de tiempo cortos intencionales. De acuerdo con la norma IEC 60947-2, estos dispositivos deben declarar una corriente nominal de resistencia de corta duraci\u00f3n (I<sub>cw<\/sub>): la corriente de falla m\u00e1xima que el interruptor puede transportar en la posici\u00f3n cerrada durante un per\u00edodo de tiempo especificado (0.05s, 0.1s, 0.25s, 0.5s o 1.0s) sin sufrir da\u00f1os.<\/p>\n<p><strong>Caracter\u00edsticas clave de los interruptores de Categor\u00eda B:<\/strong><\/p>\n<table style=\"border-collapse: collapse; width: 100%; margin: 20px 0;\" border=\"1\" cellpadding=\"10\">\n<thead>\n<tr style=\"background-color: #f2f2f2;\">\n<th>Par\u00e1metro<\/th>\n<th>Especificaci\u00f3n<\/th>\n<th>Prop\u00f3sito<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>Yo<sub>cw<\/sub> Clasificaci\u00f3n<\/strong><\/td>\n<td>M\u00ednimo 12\u00d7 I<sub>n<\/sub> o 5kA (marcos \u22642500A)<br \/>\nM\u00ednimo 30kA (marcos &gt;2500A)<\/td>\n<td>Permite el retardo intencional durante las fallas<\/td>\n<\/tr>\n<tr>\n<td><strong>Contacto Dise\u00f1o<\/strong><\/td>\n<td>Alta presi\u00f3n del resorte<\/td>\n<td>Evita la repulsi\u00f3n del contacto durante el per\u00edodo de retardo<\/td>\n<\/tr>\n<tr>\n<td><strong>Diferimiento del disparo<\/strong><\/td>\n<td>El disparo instant\u00e1neo se puede desactivar<\/td>\n<td>Permite la coordinaci\u00f3n pura basada en el tiempo<\/td>\n<\/tr>\n<tr>\n<td><strong>Aplicaci\u00f3n T\u00edpica<\/strong><\/td>\n<td>Acometidas principales, alimentadores de distribuci\u00f3n<\/td>\n<td>Se coordina con los MCCB aguas abajo<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Por ejemplo, un ACB de 800A con I<sub>cw<\/sub> = 85kA\/1s puede soportar una corriente de falla de 85kA durante hasta 1 segundo mientras el rel\u00e9 de retardo corto \u201cespera\u201d a que los dispositivos aguas abajo eliminen la falla. Esta capacidad requiere una construcci\u00f3n mec\u00e1nica robusta: brazos de contacto reforzados, alta presi\u00f3n de contacto (que evita la repulsi\u00f3n electromagn\u00e9tica) y masa t\u00e9rmica para absorber la energ\u00eda I<sup>2<\/sup>t.<\/p>\n<h3>Categor\u00eda A: MCCB sin I<sub>cw<\/sub><\/h3>\n<p>Los interruptores autom\u00e1ticos en caja moldeada (MCCB) normalmente se incluyen en <strong>Categor\u00eda A<\/strong>\u2014dispositivos \u201cno destinados espec\u00edficamente a la selectividad en condiciones de cortocircuito\u201d seg\u00fan la norma IEC 60947-2. Estos interruptores no declaran valores de I<sub>cw<\/sub> porque su filosof\u00eda de dise\u00f1o prioriza <strong>la interrupci\u00f3n r\u00e1pida de la falla<\/strong> sobre la resistencia prolongada a la falla.<\/p>\n<p><strong>Por qu\u00e9 los MCCB no declaran I<sub>cw<\/sub>:<\/strong><\/p>\n<ol>\n<li><strong>Dise\u00f1o de limitaci\u00f3n de corriente<\/strong>: La presi\u00f3n del resorte de contacto es intencionalmente baja para facilitar la repulsi\u00f3n electromagn\u00e9tica r\u00e1pida cuando la corriente de falla excede ~10-14\u00d7 I<sub>n<\/sub><\/li>\n<li><strong>Mandato de disparo instant\u00e1neo<\/strong>: La mayor\u00eda de los MCCB no pueden desactivar la protecci\u00f3n instant\u00e1nea: cualquier falla que exceda el umbral instant\u00e1neo desencadena un disparo inmediato<\/li>\n<li><strong>Limitaciones t\u00e9rmicas<\/strong>: La construcci\u00f3n moldeada compacta no puede disipar la energ\u00eda t\u00e9rmica (I<sup>2<\/sup>t) asociada con la resistencia prolongada a alta corriente<\/li>\n<\/ol>\n<p>Sin embargo, esto no <strong>no<\/strong> significa que los MCCB carezcan por completo de capacidad de resistencia de corta duraci\u00f3n: poseen un umbral inherente, no declarado, por debajo del cual los contactos permanecen cerrados.<\/p>\n<hr \/>\n<h2>La f\u00edsica de la repulsi\u00f3n de contacto MCCB<\/h2>\n<figure style=\"text-align: center; margin: 20px 0;\"><img decoding=\"async\" style=\"max-width: 100%; height: auto;\" src=\"https:\/\/img.viox.com\/MCCB-electromagnetic-contact-repulsion-mechanism-diagram-showing-force-balance-and-current-thresholds.webp\" alt=\"MCCB electromagnetic contact repulsion mechanism diagram showing force balance and current thresholds - VIOX Electric\" \/><figcaption style=\"font-style: italic; color: #555; margin-top: 8px;\">Diagrama del mecanismo de repulsi\u00f3n de contacto electromagn\u00e9tico MCCB que muestra el equilibrio de fuerzas y los umbrales de corriente \u2013 VIOX Electric<\/figcaption><\/figure>\n<h3>Umbral de repulsi\u00f3n electromagn\u00e9tica<\/h3>\n<p>Cuando la corriente de falla fluye a trav\u00e9s de rutas de contacto paralelas en un MCCB, genera campos magn\u00e9ticos opuestos que crean <strong>fuerzas de repulsi\u00f3n electrodin\u00e1micas<\/strong> (fuerza de Lorentz). El resorte de contacto debe contrarrestar esta fuerza para mantener los contactos cerrados.<\/p>\n<p><strong>Ecuaci\u00f3n de equilibrio de fuerzas:<\/strong><\/p>\n<p style=\"text-align: center; background-color: #f9f9f9; padding: 10px; border-radius: 4px;\">F<sub>resorte<\/sub> &gt; F<sub>repulsi\u00f3n<\/sub> = k \u00b7 I<sup>2<\/sup><\/p>\n<p>Donde:<\/p>\n<ul>\n<li>F<sub>resorte<\/sub> = Fuerza de compresi\u00f3n del resorte de contacto<\/li>\n<li>F<sub>repulsi\u00f3n<\/sub> = Fuerza de repulsi\u00f3n electromagn\u00e9tica (proporcional a I<sup>2<\/sup>)<\/li>\n<li>k = Constante geom\u00e9trica (espaciamiento de contactos, configuraci\u00f3n del conductor)<\/li>\n<\/ul>\n<table style=\"border-collapse: collapse; width: 100%; margin: 20px 0;\" border=\"1\" cellpadding=\"10\">\n<thead>\n<tr style=\"background-color: #f2f2f2;\">\n<th>Par\u00e1metro de dise\u00f1o de MCCB<\/th>\n<th>Categor\u00eda A (MCCB)<\/th>\n<th>Categor\u00eda B (ACB)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>Presi\u00f3n del resorte de contacto<\/strong><\/td>\n<td>Baja (2-5 N\/mm)<\/td>\n<td>Alta (10-20 N\/mm)<\/td>\n<\/tr>\n<tr>\n<td><strong>Umbral de repulsi\u00f3n<\/strong><\/td>\n<td>12-14\u00d7 I<sub>n<\/sub><\/td>\n<td>&gt;50\u00d7 I<sub>n<\/sub><\/td>\n<\/tr>\n<tr>\n<td><strong>Velocidad de apertura de contacto<\/strong><\/td>\n<td>3-7 ms (ultra-r\u00e1pido)<\/td>\n<td>20-50 ms (controlado)<\/td>\n<\/tr>\n<tr>\n<td><strong>Dise\u00f1o De Prioridad<\/strong><\/td>\n<td>Limitar la energ\u00eda de falla (I<sup>2<\/sup>t)<\/td>\n<td>Soportar la duraci\u00f3n de la falla<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Consideraciones sobre el arranque del motor<\/h3>\n<p>La investigaci\u00f3n realizada por el Instituto de Investigaci\u00f3n El\u00e9ctrica de Shangh\u00e1i en 52 muestras de motores revel\u00f3 que el arranque directo (DOL) produce corrientes de irrupci\u00f3n del primer pico de <strong>8-12\u00d7 I<sub>n<\/sub><\/strong> para la mayor\u00eda de los motores, con valores at\u00edpicos que alcanzan 13\u00d7 I<sub>n<\/sub>.<\/p>\n<p><strong>Estos datos impulsan las restricciones de dise\u00f1o de MCCB:<\/strong><\/p>\n<ul>\n<li><strong>MCCB de distribuci\u00f3n<\/strong>: Disparo instant\u00e1neo ajustado a 10-12\u00d7 I<sub>n<\/sub> (no debe dispararse por la irrupci\u00f3n del capacitor o la energizaci\u00f3n del transformador)<\/li>\n<li><strong>MCCB con clasificaci\u00f3n de motor<\/strong>: Disparo instant\u00e1neo ajustado a 13-14\u00d7 I<sub>n<\/sub> (debe soportar el arranque DOL)<\/li>\n<li><strong>Umbral de repulsi\u00f3n de contacto<\/strong>: Debe exceder el ajuste de disparo instant\u00e1neo en un margen de 15-20% para evitar la apertura de contacto molesta durante los transitorios de arranque<\/li>\n<\/ul>\n<p><strong>Ejemplo de c\u00e1lculo para un MCCB con clasificaci\u00f3n de motor de 100 A:<\/strong><\/p>\n<div style=\"background-color: #f5f5f5; padding: 15px; border-radius: 5px; margin: 15px 0; font-family: monospace;\">Ajuste de disparo instant\u00e1neo: 13 \u00d7 100 A = 1300 A<br \/>\nUmbral de repulsi\u00f3n de contacto: 1300 A \u00d7 1,2 = 1560 A (objetivo de dise\u00f1o)<br \/>\nCapacidad \u201cIcw\u201d no declarada: ~1500 A (por debajo del umbral de repulsi\u00f3n)<\/div>\n<p>Este umbral de 1500 A representa la capacidad inherente de resistencia a corto tiempo del MCCB, suficiente para la coordinaci\u00f3n con los dispositivos aguas abajo en el rango de falla de 1000-1500 A, pero muy por debajo de la I<sub>cw<\/sub> valores de ACB (t\u00edpicamente 30-85kA).<\/p>\n<hr \/>\n<h2>C\u00f3mo funciona realmente el retardo de corto tiempo de MCCB<\/h2>\n<figure style=\"text-align: center; margin: 20px 0;\"><img decoding=\"async\" style=\"max-width: 100%; height: auto;\" src=\"https:\/\/img.viox.com\/Technical-infographic-clean-202601280514.webp\" alt=\"MCCB three-zone protection logic diagram showing overload, short-time delay, and instantaneous trip thresholds - VIOX Electric\" \/><figcaption style=\"font-style: italic; color: #555; margin-top: 8px;\">Diagrama l\u00f3gico de protecci\u00f3n de tres zonas de MCCB que muestra los umbrales de sobrecarga, retardo de corto tiempo y disparo instant\u00e1neo \u2013 VIOX Electric<\/figcaption><\/figure>\n<h3>Las tres zonas de operaci\u00f3n<\/h3>\n<p>Los MCCB modernos de disparo electr\u00f3nico cuentan con tres zonas de protecci\u00f3n, pero su interacci\u00f3n difiere fundamentalmente de los ACB:<\/p>\n<table style=\"border-collapse: collapse; width: 100%; margin: 20px 0;\" border=\"1\" cellpadding=\"10\">\n<thead>\n<tr style=\"background-color: #f2f2f2;\">\n<th>Zona de protecci\u00f3n<\/th>\n<th>Rango de ajuste<\/th>\n<th>Comportamiento real<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>Largo tiempo (sobrecarga)<\/strong><\/td>\n<td>0.4-1.0\u00d7 I<sub>n<\/sub>, 3-30s<\/td>\n<td>Protecci\u00f3n t\u00e9rmica v\u00eda I<sup>2<\/sup>t c\u00e1lculo<\/td>\n<\/tr>\n<tr>\n<td><strong>Retardo de corta duraci\u00f3n<\/strong><\/td>\n<td>2-12\u00d7 I<sub>n<\/sub>, 0.1-0.5s<\/td>\n<td><strong>Solo activo por debajo del umbral instant\u00e1neo<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>Instant\u00e1neo<\/strong><\/td>\n<td>10-14\u00d7 I<sub>n<\/sub> (fijo o ajustable)<\/td>\n<td><strong>No se puede desactivar en la mayor\u00eda de los MCCB<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Escenario 1: Corriente de falla por debajo del umbral instant\u00e1neo<\/h3>\n<p><strong>Condiciones<\/strong>: Corriente de falla = 8\u00d7 I<sub>n<\/sub> (800 A para un interruptor de 100 A)<\/p>\n<ol>\n<li>La corriente excede la zona de tiempo largo \u2192 Se activa el retardo de tiempo corto<\/li>\n<li>La unidad de disparo electr\u00f3nico inicia la cuenta regresiva (p. ej., 0,4 s)<\/li>\n<li>Si la falla persiste, la bobina de disparo se energiza despu\u00e9s del retardo<\/li>\n<li>Los contactos se abren mediante un mecanismo de energ\u00eda almacenada (tiempo de apertura de ~20-30 ms)<\/li>\n<\/ol>\n<p><strong>Resultado<\/strong>: Coordinaci\u00f3n de tiempo retardado real con dispositivos aguas abajo<\/p>\n<h3>Escenario 2: Corriente de falla por encima del umbral instant\u00e1neo<\/h3>\n<p><strong>Condiciones<\/strong>: Corriente de falla = 15 \u00d7 I<sub>n<\/sub> (1500 A para un interruptor de 100 A)<\/p>\n<ol>\n<li>La corriente excede el umbral instant\u00e1neo \u2192 El disparo magn\u00e9tico se activa inmediatamente<\/li>\n<li>El ajuste de retardo de tiempo corto es <strong>omitido<\/strong><\/li>\n<li>La bobina de disparo se energiza en 5-10 ms<\/li>\n<li>Los contactos se abren, pero la corriente de falla puede haber causado ya repulsi\u00f3n electromagn\u00e9tica<\/li>\n<\/ol>\n<p><strong>Resultado<\/strong>: Sin retardo intencional: el MCCB se dispara lo m\u00e1s r\u00e1pido posible<\/p>\n<h3>Escenario 3: La corriente de falla excede con creces el umbral de repulsi\u00f3n<\/h3>\n<p><strong>Condiciones<\/strong>: Corriente de falla = 50 \u00d7 I<sub>n<\/sub> (5000 A para un interruptor de 100 A, acerc\u00e1ndose a I<sub>cu<\/sub>)<\/p>\n<ol>\n<li>La fuerza de repulsi\u00f3n electromagn\u00e9tica excede la presi\u00f3n del resorte<\/li>\n<li>Los contactos se separan en 3-7 ms (m\u00e1s r\u00e1pido que el mecanismo de disparo)<\/li>\n<li>El voltaje del arco aumenta r\u00e1pidamente, limitando la corriente m\u00e1xima (acci\u00f3n de limitaci\u00f3n de corriente)<\/li>\n<li>La energ\u00eda del arco puede activar el mecanismo de disparo, o el interruptor autom\u00e1tico se basa \u00fanicamente en la extinci\u00f3n del arco<\/li>\n<\/ol>\n<p><strong>Resultado<\/strong>: Limitaci\u00f3n de corriente ultrarr\u00e1pida: sin coordinaci\u00f3n, pero protecci\u00f3n del equipo a trav\u00e9s de la reducci\u00f3n de I<sup>2<\/sup>t<\/p>\n<hr \/>\n<h2>Caso especial: MCCB con disparo instant\u00e1neo desactivable<\/h2>\n<h3>Mecanismo de \u201cDisparo de energ\u00eda\u201d Schneider NSX<\/h3>\n<p>Algunos MCCB de alta gama (p. ej., Schneider Electric NSX con unidades de disparo Micrologic) permiten que la protecci\u00f3n instant\u00e1nea se desactive para mejorar la selectividad. Sin embargo, estos dispositivos incorporan una <strong>anulaci\u00f3n de seguridad obligatoria<\/strong> llamada \u201cdisparo de energ\u00eda\u201d o \u201canulaci\u00f3n instant\u00e1nea\u201d.\u201d<\/p>\n<p><strong>C\u00f3mo funciona:<\/strong><\/p>\n<ol>\n<li>El usuario desactiva el disparo instant\u00e1neo, habilita el retardo de tiempo corto (p. ej., 10 \u00d7 I<sub>n<\/sub>, 0,4 s)<\/li>\n<li>La corriente de falla alcanza 30 \u00d7 I<sub>n<\/sub> (3000 A para un interruptor de 100 A)<\/li>\n<li>Los contactos se repelen, se forma un arco<\/li>\n<li>La energ\u00eda del arco ioniza el material generador de gas en la c\u00e1mara de arco<\/li>\n<li>El aumento de presi\u00f3n activa el mecanismo de disparo neum\u00e1tico en 10-15 ms<\/li>\n<li>El interruptor autom\u00e1tico se dispara <strong>independientemente de la configuraci\u00f3n de la unidad de disparo electr\u00f3nico<\/strong><\/li>\n<\/ol>\n<table style=\"border-collapse: collapse; width: 100%; margin: 20px 0;\" border=\"1\" cellpadding=\"10\">\n<thead>\n<tr style=\"background-color: #f2f2f2;\">\n<th>Nivel de corriente de falla<\/th>\n<th>Respuesta NSX<\/th>\n<th>Respuesta MCCB est\u00e1ndar<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>8 \u00d7 I<sub>n<\/sub><\/strong><\/td>\n<td>El retardo de tiempo corto funciona normalmente<\/td>\n<td>El retardo de tiempo corto funciona<\/td>\n<\/tr>\n<tr>\n<td><strong>15 \u00d7 I<sub>n<\/sub><\/strong><\/td>\n<td>El retardo de tiempo corto funciona (inst. desactivado)<\/td>\n<td>Disparo instant\u00e1neo (no se puede desactivar)<\/td>\n<\/tr>\n<tr>\n<td><strong>&gt;25 \u00d7 I<sub>n<\/sub><\/strong><\/td>\n<td>El disparo de energ\u00eda anula el retardo<\/td>\n<td>Repulsi\u00f3n de contacto + disparo instant\u00e1neo<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Este dise\u00f1o evita fallas catastr\u00f3ficas cuando los usuarios configuran incorrectamente los ajustes de protecci\u00f3n: el MCCB siempre se autoproteger\u00e1 en niveles de falla extremos, incluso si compromete la selectividad.<\/p>\n<hr \/>\n<h2>Estrategias pr\u00e1cticas de coordinaci\u00f3n<\/h2>\n<figure style=\"text-align: center; margin: 20px 0;\"><img decoding=\"async\" style=\"max-width: 100%; height: auto;\" src=\"https:\/\/img.viox.com\/Time-current-coordination-diagram-showing-ACB-and-MCCB-selectivity-zones-with-fault-scenario-analysis.webp\" alt=\"Time-current coordination diagram showing ACB and MCCB selectivity zones with fault scenario analysis - VIOX Electric\" \/><figcaption style=\"font-style: italic; color: #555; margin-top: 8px;\">Diagrama de coordinaci\u00f3n de tiempo-corriente que muestra las zonas de selectividad ACB y MCCB con an\u00e1lisis de escenarios de falla \u2013 VIOX Electric<\/figcaption><\/figure>\n<h3>Estrategia 1: Cascada ACB a MCCB (Recomendada)<\/h3>\n<p><strong>Configuraci\u00f3n:<\/strong><\/p>\n<ul>\n<li><strong>Aguas arriba<\/strong>: ACB de 1600 A, I<sub>cw<\/sub> = 65 kA\/0,5 s, retardo de tiempo corto = 0,4 s<\/li>\n<li><strong>Aguas abajo<\/strong>: MCCB de 400 A, I<sub>cu<\/sub> = 50 kA, instant\u00e1neo = 5000 A (12,5 \u00d7 I<sub>n<\/sub>)<\/li>\n<\/ul>\n<p><strong>An\u00e1lisis de coordinaci\u00f3n:<\/strong><\/p>\n<table style=\"border-collapse: collapse; width: 100%; margin: 20px 0;\" border=\"1\" cellpadding=\"10\">\n<thead>\n<tr style=\"background-color: #f2f2f2;\">\n<th>Ubicaci\u00f3n de la falla<\/th>\n<th>Corriente de falla<\/th>\n<th>Acci\u00f3n ACB aguas arriba<\/th>\n<th>Acci\u00f3n MCCB aguas abajo<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>Alimentador aguas abajo<\/strong><\/td>\n<td>8 kA<\/td>\n<td>Espera 0,4 s (dentro de I<sub>cw<\/sub>)<\/td>\n<td>Dispara instant\u00e1neamente (&gt;12.5\u00d7 I<sub>n<\/sub>)<\/td>\n<\/tr>\n<tr>\n<td><strong>Alimentador aguas abajo<\/strong><\/td>\n<td>45 kA<\/td>\n<td>Espera 0,4 s (dentro de I<sub>cw<\/sub>)<\/td>\n<td>Dispara instant\u00e1neamente (limitaci\u00f3n de corriente)<\/td>\n<\/tr>\n<tr>\n<td><strong>Barra colectora principal<\/strong><\/td>\n<td>60 kA<\/td>\n<td>Dispara despu\u00e9s de 0.4s<\/td>\n<td>No afectado<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Resultado<\/strong>: Selectividad total hasta 50kA (MCCB I<sub>cu<\/sub> l\u00edmite)<\/p>\n<h3>Estrategia 2: Coordinaci\u00f3n MCCB a MCCB (Limitada)<\/h3>\n<p><strong>Configuraci\u00f3n:<\/strong><\/p>\n<ul>\n<li><strong>Aguas arriba<\/strong>: MCCB de 400A, instant\u00e1neo = 5,000A (12.5\u00d7 I<sub>n<\/sub>)<\/li>\n<li><strong>Aguas abajo<\/strong>: MCCB de 100A, instant\u00e1neo = 1,300A (13\u00d7 I<sub>n<\/sub>)<\/li>\n<\/ul>\n<p><strong>An\u00e1lisis de coordinaci\u00f3n:<\/strong><\/p>\n<table style=\"border-collapse: collapse; width: 100%; margin: 20px 0;\" border=\"1\" cellpadding=\"10\">\n<thead>\n<tr style=\"background-color: #f2f2f2;\">\n<th>Corriente de falla<\/th>\n<th>MCCB aguas arriba<\/th>\n<th>MCCB aguas abajo<\/th>\n<th>\u00bfSelectividad?<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>1.500 A<\/strong><\/td>\n<td>Retardo corto (0.3s)<\/td>\n<td>Viaje instant\u00e1neo<\/td>\n<td>\u2705 S\u00ed<\/td>\n<\/tr>\n<tr>\n<td><strong>4,000A<\/strong><\/td>\n<td>Retardo corto (0.3s)<\/td>\n<td>Viaje instant\u00e1neo<\/td>\n<td>\u2705 S\u00ed<\/td>\n<\/tr>\n<tr>\n<td><strong>6,000A<\/strong><\/td>\n<td><strong>Viaje instant\u00e1neo<\/strong><\/td>\n<td>Viaje instant\u00e1neo<\/td>\n<td>\u274c No (ambos disparan)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>L\u00edmite de selectividad<\/strong>: ~4,500A (90% del ajuste instant\u00e1neo aguas arriba)<\/p>\n<p><strong>Mejora<\/strong>: Utilice las tablas de coordinaci\u00f3n del fabricante para verificar la energ\u00eda de paso real; los MCCB de limitaci\u00f3n de corriente a\u00fan pueden lograr selectividad a niveles de falla m\u00e1s altos a trav\u00e9s de la discriminaci\u00f3n I<sup>2<\/sup>t.<\/p>\n<hr \/>\n<h2>Tabla comparativa: Caracter\u00edsticas de cortocircuito de ACB vs. MCCB<\/h2>\n<table style=\"border-collapse: collapse; width: 100%; margin: 20px 0;\" border=\"1\" cellpadding=\"10\">\n<thead>\n<tr style=\"background-color: #f2f2f2;\">\n<th>Caracter\u00edstica<\/th>\n<th>ACB (Categor\u00eda B)<\/th>\n<th>MCCB (Categor\u00eda A)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>Yo<sub>cw<\/sub> Declaraci\u00f3n<\/strong><\/td>\n<td>\u2705 S\u00ed (30-85 kA, 0.05-1.0s)<\/td>\n<td>\u274c No (no declarado)<\/td>\n<\/tr>\n<tr>\n<td><strong>Resistencia inherente<\/strong><\/td>\n<td>Muy alto (&gt;50\u00d7 I<sub>n<\/sub>)<\/td>\n<td>Limitado (12-14\u00d7 I<sub>n<\/sub>)<\/td>\n<\/tr>\n<tr>\n<td><strong>Presi\u00f3n del resorte de contacto<\/strong><\/td>\n<td>Alto (previene la repulsi\u00f3n)<\/td>\n<td>Bajo (permite la limitaci\u00f3n de corriente)<\/td>\n<\/tr>\n<tr>\n<td><strong>Disparo instant\u00e1neo<\/strong><\/td>\n<td>Se puede desactivar<\/td>\n<td>Generalmente fijo (no se puede desactivar)<\/td>\n<\/tr>\n<tr>\n<td><strong>Rango de retardo de cortocircuito<\/strong><\/td>\n<td>0.05-1.0s (ajustable)<\/td>\n<td>0.1-0.5s (solo por debajo del umbral instant\u00e1neo)<\/td>\n<\/tr>\n<tr>\n<td><strong>M\u00e9todo de coordinaci\u00f3n<\/strong><\/td>\n<td>Basado en el tiempo (retardo verdadero)<\/td>\n<td>Basado en la corriente (limitaci\u00f3n + retardo)<\/td>\n<\/tr>\n<tr>\n<td><strong>Aplicaci\u00f3n T\u00edpica<\/strong><\/td>\n<td>Acometida principal (1000-6300A)<\/td>\n<td>Protecci\u00f3n de alimentador (16-1600A)<\/td>\n<\/tr>\n<tr>\n<td><strong>Selectividad con aguas abajo<\/strong><\/td>\n<td>Completa (hasta I<sub>cw<\/sub>)<\/td>\n<td>Parcial (hasta el umbral instant\u00e1neo)<\/td>\n<\/tr>\n<tr>\n<td><strong>Mecanismo de autoprotecci\u00f3n<\/strong><\/td>\n<td>Masa t\u00e9rmica + resistencia mec\u00e1nica<\/td>\n<td>Repulsi\u00f3n de contacto + limitaci\u00f3n de arco<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<hr \/>\n<h2>Por qu\u00e9 esto es importante para el dise\u00f1o del sistema<\/h2>\n<h3>Idea err\u00f3nea 1: \u201cRetardo de cortocircuito MCCB = Retardo de cortocircuito ACB\u201d<\/h3>\n<p><strong>Realidad<\/strong>: El retardo de cortocircuito MCCB solo funciona dentro de una ventana de corriente estrecha (entre los umbrales de larga duraci\u00f3n e instant\u00e1neos). Para fallas que exceden la configuraci\u00f3n instant\u00e1nea, los MCCB se disparan inmediatamente, sin que se produzca ning\u00fan retardo.<\/p>\n<p><strong>Impacto en el dise\u00f1o<\/strong>: Al especificar la protecci\u00f3n MCCB, siempre verifique:<\/p>\n<ol>\n<li>Ajustes instant\u00e1neos del dispositivo aguas abajo<\/li>\n<li>Corriente de falla m\u00e1xima en el punto de coordinaci\u00f3n<\/li>\n<li>Si la corriente de falla exceder\u00e1 el umbral instant\u00e1neo del MCCB aguas arriba<\/li>\n<\/ol>\n<h3>Idea err\u00f3nea 2: \u201cSin I<sub>cw<\/sub> Clasificaci\u00f3n = Sin capacidad de cortocircuito\u201d<\/h3>\n<p><strong>Realidad<\/strong>: Los MCCB poseen una resistencia inherente a cortocircuitos hasta su umbral de repulsi\u00f3n de contacto (~12-14\u00d7 I<sub>n<\/sub>). Esta capacidad permite una coordinaci\u00f3n limitada con los dispositivos aguas abajo, aunque no en la medida de los ACB.<\/p>\n<p><strong>Impacto en el dise\u00f1o<\/strong>: La coordinaci\u00f3n MCCB a MCCB es posible pero requiere:<\/p>\n<ul>\n<li>Separaci\u00f3n cuidadosa de la configuraci\u00f3n instant\u00e1nea (relaci\u00f3n m\u00ednima de 1.5:1)<\/li>\n<li>Tablas de selectividad proporcionadas por el fabricante<\/li>\n<li>Consideraci\u00f3n de los efectos de limitaci\u00f3n de corriente en la energ\u00eda pasante<\/li>\n<\/ul>\n<h3>Idea err\u00f3nea 3: \u201cDeshabilitar el disparo instant\u00e1neo hace que MCCB = ACB\u201d<\/h3>\n<p><strong>Realidad<\/strong>: Incluso los MCCB con disparos instant\u00e1neos desactivables (por ejemplo, NSX) incorporan mecanismos de anulaci\u00f3n basados en energ\u00eda que fuerzan el disparo en niveles de falla extremos (&gt;25\u00d7 I<sub>n<\/sub>). No pueden \u201cesperar\u201d altas corrientes de falla como los ACB.<\/p>\n<p><strong>Impacto en el dise\u00f1o<\/strong>: Cuando utilice MCCB con instant\u00e1neo ajustable:<\/p>\n<ul>\n<li>Verifique el umbral de disparo de energ\u00eda con el fabricante<\/li>\n<li>No asuma un comportamiento similar al de ACB con corrientes de falla que se aproximan a I<sub>cu<\/sub><\/li>\n<li>Considere las implicaciones de la energ\u00eda del arco el\u00e9ctrico del disparo retardado<\/li>\n<\/ul>\n<hr \/>\n<h2>Enlaces internos y recursos relacionados<\/h2>\n<p>Para una comprensi\u00f3n m\u00e1s profunda de los conceptos de protecci\u00f3n relacionados, explore estas gu\u00edas t\u00e9cnicas de VIOX:<\/p>\n<ul>\n<li><a href=\"https:\/\/test.viox.com\/es\/electrical-derating-temperature-altitude-grouping-factors\/\"><strong>Reducci\u00f3n de potencia el\u00e9ctrica: temperatura, altitud y factores de agrupaci\u00f3n<\/strong><\/a> \u2013 Aprenda c\u00f3mo los factores ambientales afectan las clasificaciones de corriente y la coordinaci\u00f3n del interruptor<\/li>\n<li><a href=\"https:\/\/test.viox.com\/es\/ats-circuit-breaker-coordination-guide-icw-selectivity\/\"><strong>Gu\u00eda de coordinaci\u00f3n de ATS e interruptores autom\u00e1ticos: I<sub>cw<\/sub> y selectividad explicadas<\/strong><\/a> \u2013 An\u00e1lisis detallado de la coordinaci\u00f3n de categor\u00eda A frente a B en aplicaciones de interruptores de transferencia autom\u00e1tica<\/li>\n<li><a href=\"https:\/\/test.viox.com\/es\/current-limiting-circuit-breaker-guide\/\"><strong>Limitaci\u00f3n De Corriente Interruptor De Circuito De La Gu\u00eda: Protecci\u00f3n Y Especificaciones<\/strong><\/a> \u2013 Inmersi\u00f3n profunda en la f\u00edsica de la repulsi\u00f3n electromagn\u00e9tica e I<sup>2<\/sup>limitaci\u00f3n de t<\/li>\n<li><a href=\"https:\/\/test.viox.com\/es\/types-of-circuit-breakers\/\"><strong>Tipos de interruptores autom\u00e1ticos: gu\u00eda completa de clasificaci\u00f3n<\/strong><\/a> \u2013 Descripci\u00f3n general completa de las diferencias y aplicaciones de ACB, MCCB, MCB<\/li>\n<li><a href=\"https:\/\/test.viox.com\/es\/commercial-ev-charging-protection-guide-acb-mccb-rcbo\/\"><strong>Gu\u00eda de protecci\u00f3n de carga de veh\u00edculos el\u00e9ctricos comerciales: ACB, MCCB y RCBO tipo B<\/strong><\/a> \u2013 Ejemplo de coordinaci\u00f3n del mundo real con c\u00e1lculos de carga<\/li>\n<\/ul>\n<hr \/>\n<h2>Preguntas frecuentes: Protecci\u00f3n de cortocircuito MCCB<\/h2>\n<h3>P1: \u00bfPuedo usar un MCCB como entrada principal en lugar de un ACB?<\/h3>\n<p><strong>Un<\/strong>: Posible, pero no recomendado para sistemas que requieren selectividad total. Los MCCB carecen de I<sub>cw<\/sub> declaradas, por lo que no pueden retrasar de manera confiable el disparo para la coordinaci\u00f3n aguas abajo con altas corrientes de falla (&gt;10\u00d7 I<sub>n<\/sub>). Utilice ACB para las entradas principales en instalaciones industriales donde la selectividad es fundamental, o verifique los l\u00edmites de coordinaci\u00f3n con las tablas del fabricante para aplicaciones comerciales.<\/p>\n<h3>P2: \u00bfQu\u00e9 sucede si configuro el retardo de cortocircuito del MCCB en 0,5 s pero la corriente de falla es 20\u00d7 I<sub>n<\/sub>?<\/h3>\n<p><strong>Un<\/strong>: El interruptor se disparar\u00e1 <strong>instant\u00e1neamente<\/strong> mediante disparo magn\u00e9tico, ignorando la configuraci\u00f3n de retardo de 0,5 s. Los retardos de cortocircuito del MCCB solo funcionan cuando la corriente de falla se mantiene entre la captaci\u00f3n de cortocircuito (por ejemplo, 2-10\u00d7 I<sub>n<\/sub>) y el umbral instant\u00e1neo (por ejemplo, 12\u00d7 I<sub>n<\/sub>). Por encima del instant\u00e1neo, el elemento magn\u00e9tico anula la configuraci\u00f3n electr\u00f3nica.<\/p>\n<h3>P3: \u00bfTodos los MCCB utilizan tecnolog\u00eda de limitaci\u00f3n de corriente?<\/h3>\n<p><strong>Un<\/strong>: No. Los MCCB t\u00e9rmicos-magn\u00e9ticos (disparo fijo, sin capacidad de ajuste) normalmente utilizan elementos de sobrecarga bimet\u00e1licos m\u00e1s lentos y es posible que no logren una verdadera limitaci\u00f3n de corriente. Es m\u00e1s probable que los MCCB de disparo electr\u00f3nico con contactos de acci\u00f3n r\u00e1pida y conductos de arco optimizados limiten la corriente (verifique con las curvas de paso del fabricante que muestran I<sub>p<\/sub> e I<sup>2<\/sup>valores de t por debajo de los niveles de falla prospectivos).<\/p>\n<h3>P4: \u00bfC\u00f3mo verifico la selectividad entre dos MCCB?<\/h3>\n<p><strong>Un<\/strong>: Utilice las tablas de coordinaci\u00f3n del fabricante (no solo las curvas de tiempo-corriente). Las tablas tienen en cuenta:<\/p>\n<ul>\n<li>Energ\u00eda pasante (I<sup>2<\/sup>t) del interruptor aguas abajo<\/li>\n<li>Umbral de energ\u00eda de no disparo del interruptor aguas arriba<\/li>\n<li>Efectos de limitaci\u00f3n de corriente en varios niveles de falla<br \/>\nEjemplo: Schneider Electric proporciona tablas de selectividad detalladas en sus gu\u00edas de coordinaci\u00f3n que muestran los l\u00edmites m\u00e1ximos de selectividad (por ejemplo, \u201cSelectivo hasta 15 kA\u201d entre modelos espec\u00edficos de MCCB).<\/li>\n<\/ul>\n<h3>P5: \u00bfPor qu\u00e9 los MCCB con clasificaci\u00f3n de motor tienen ajustes instant\u00e1neos m\u00e1s altos (13-14\u00d7 I<sub>n<\/sub>)?<\/h3>\n<p><strong>Un<\/strong>: Para evitar disparos molestos durante el arranque directo en l\u00ednea (DOL) del motor. Las investigaciones muestran que la corriente de irrupci\u00f3n del motor puede alcanzar 12-13\u00d7 I<sub>n<\/sub> para el primer pico. Los MCCB con clasificaci\u00f3n de motor tambi\u00e9n tienen umbrales de repulsi\u00f3n de contacto m\u00e1s altos (&gt;14\u00d7 I<sub>n<\/sub>) para garantizar que los contactos no se abran durante los transitorios de arranque, lo que provocar\u00eda un desgaste innecesario y una posible soldadura al volver a cerrar.<\/p>\n<hr \/>\n<h2>Conclusi\u00f3n<\/h2>\n<p>La aparente paradoja de los MCCB que ofrecen protecci\u00f3n de retardo de cortocircuito sin I<sub>cw<\/sub> nominales surge de una diferencia fundamental en la filosof\u00eda de protecci\u00f3n: <strong>Los ACB resisten las fallas a trav\u00e9s de la resistencia mec\u00e1nica y la masa t\u00e9rmica, mientras que los MCCB limitan las fallas a trav\u00e9s de la f\u00edsica electromagn\u00e9tica y la interrupci\u00f3n r\u00e1pida del arco.<\/strong><\/p>\n<p>Comprender esta distinci\u00f3n es fundamental para los ingenieros el\u00e9ctricos que dise\u00f1an esquemas de coordinaci\u00f3n. Los MCCB pueden lograr una coordinaci\u00f3n selectiva con los dispositivos aguas abajo dentro de su capacidad inherente de resistencia a cortocircuitos (normalmente 12-14\u00d7 I<sub>n<\/sub>), pero no pueden replicar el comportamiento de ACB con altas corrientes de falla que se aproximan a su capacidad de ruptura. Para las aplicaciones que requieren una selectividad total en todo el rango de corriente de falla, las entradas principales de ACB que se coordinan con los alimentadores de MCCB siguen siendo el est\u00e1ndar de oro, aprovechando las capacidades de retardo de tiempo de la Categor\u00eda B aguas arriba mientras explotan los beneficios de limitaci\u00f3n de corriente de la Categor\u00eda A aguas abajo.<\/p>\n<p><strong>Principio de dise\u00f1o clave<\/strong>: Haga coincidir la categor\u00eda de interruptor con la aplicaci\u00f3n: use ACB donde necesite \u201cesperar\u201d las fallas, use MCCB donde necesite \u201celiminar las fallas r\u00e1pidamente\u201d.\u201d<\/p>\n<hr \/>\n<p><strong>Acerca de VIOX Electric<\/strong>: VIOX Electric es un fabricante B2B l\u00edder de equipos el\u00e9ctricos, que se especializa en interruptores autom\u00e1ticos de caja moldeada (MCCB), interruptores autom\u00e1ticos de aire (ACB) y soluciones de protecci\u00f3n integrales para aplicaciones industriales y comerciales. Nuestro equipo de ingenier\u00eda brinda soporte t\u00e9cnico para estudios de coordinaci\u00f3n complejos y optimizaci\u00f3n del dise\u00f1o del sistema. <a href=\"https:\/\/test.viox.com\/es\/\">P\u00f3ngase en contacto con nosotros<\/a> para obtener orientaci\u00f3n espec\u00edfica de la aplicaci\u00f3n.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>MCCB electronic trip unit in industrial panel showing 400A rating and current display &#8211; VIOX Electric Direct Answer Molded Case Circuit Breakers (MCCBs) can provide short-time delay protection without a rated short-time withstand current (Icw) because they belong to IEC 60947-2 Category A, where selectivity is achieved through current-limiting technology rather than intentional time delays. [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":21475,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1],"tags":[],"class_list":["post-21474","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"_links":{"self":[{"href":"https:\/\/test.viox.com\/es\/wp-json\/wp\/v2\/posts\/21474","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/test.viox.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/test.viox.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/test.viox.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/test.viox.com\/es\/wp-json\/wp\/v2\/comments?post=21474"}],"version-history":[{"count":1,"href":"https:\/\/test.viox.com\/es\/wp-json\/wp\/v2\/posts\/21474\/revisions"}],"predecessor-version":[{"id":21476,"href":"https:\/\/test.viox.com\/es\/wp-json\/wp\/v2\/posts\/21474\/revisions\/21476"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/test.viox.com\/es\/wp-json\/wp\/v2\/media\/21475"}],"wp:attachment":[{"href":"https:\/\/test.viox.com\/es\/wp-json\/wp\/v2\/media?parent=21474"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/test.viox.com\/es\/wp-json\/wp\/v2\/categories?post=21474"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/test.viox.com\/es\/wp-json\/wp\/v2\/tags?post=21474"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}