{"id":20076,"date":"2025-11-29T01:45:00","date_gmt":"2025-11-28T17:45:00","guid":{"rendered":"https:\/\/viox.com\/?p=20076"},"modified":"2025-11-15T15:45:18","modified_gmt":"2025-11-15T07:45:18","slug":"solar-pv-fuse-requirements-nec-690-9-parallel-strings","status":"publish","type":"post","link":"https:\/\/test.viox.com\/es\/solar-pv-fuse-requirements-nec-690-9-parallel-strings\/","title":{"rendered":"La \u201cParadoja del Fusible\u201d: Por Qu\u00e9 NEC 690.9 Dice que No Necesita un Fusible (Pero Podr\u00eda Querer Uno de Todos Modos)"},"content":{"rendered":"<div class=\"product-intro\">\n<p>Si est\u00e1 dise\u00f1ando un arreglo solar, conoce la regla de oro de la ingenier\u00eda el\u00e9ctrica: <strong>Los cables deben estar protegidos por fusibles o <a href=\"https:\/\/test.viox.com\/es\/mcb\/\">interruptores<\/a>.<\/strong><\/p>\n<p>Entonces, cuando profundice en la Secci\u00f3n 690.9 del C\u00f3digo El\u00e9ctrico Nacional (NEC), podr\u00eda encontrarse con una cl\u00e1usula que lo detenga en seco. Sugiere que si tiene dos cadenas de paneles solares conectados en paralelo, usted <strong>no<\/strong> necesita instalar fusibles.<\/p>\n<p>Esto se siente mal. Se siente como un error tipogr\u00e1fico. \u00bfC\u00f3mo puede una fuente de energ\u00eda no requerir protecci\u00f3n?<\/p>\n<p>Bienvenido a la <strong>\u201cParadoja del fusible\u201d.\u201d<\/strong><\/p>\n<p>Esta regla existe no porque el NEC sea flexible en materia de seguridad, sino porque la f\u00edsica de un panel solar es fundamentalmente diferente a la de una bater\u00eda o la red el\u00e9ctrica. Comprender esta paradoja es la clave para distinguir a un instalador de \u201cc\u00f3digo m\u00ednimo\u201d de un verdadero ingeniero solar.<\/p>\n<hr \/>\n<h2>La f\u00edsica: \u201c\u00bfQui\u00e9n est\u00e1 atacando a qui\u00e9n?\u201d<\/h2>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-20079\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-Physics-22Who-Is-Attacking-Whom221.webp\" alt=\"The Physics: &quot;Who Is Attacking Whom?&quot;\" width=\"800\" height=\"800\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-Physics-22Who-Is-Attacking-Whom221.webp 800w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-Physics-22Who-Is-Attacking-Whom221-300x300.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-Physics-22Who-Is-Attacking-Whom221-150x150.webp 150w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-Physics-22Who-Is-Attacking-Whom221-768x768.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-Physics-22Who-Is-Attacking-Whom221-12x12.webp 12w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-Physics-22Who-Is-Attacking-Whom221-600x600.webp 600w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-Physics-22Who-Is-Attacking-Whom221-100x100.webp 100w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<p>Para comprender por qu\u00e9 no necesita un fusible, primero debe comprender contra qu\u00e9 est\u00e1 protegiendo realmente un fusible en un sistema fotovoltaico.<\/p>\n<p>En un circuito dom\u00e9stico est\u00e1ndar, el fusible protege el cable de la <em>fuente<\/em> (la red el\u00e9ctrica). Si cortocircuita un cable, la red descarga corriente infinita hasta que el cable se derrite.<\/p>\n<p><strong>Los paneles solares son diferentes.<\/strong> Son \u201cFuentes de corriente limitada\u201d.\u201d<\/p>\n<p>Si tiene un panel solar de 10 A y cortocircuita sus cables positivo y negativo, no explotar\u00e1. Simplemente producir\u00e1... alrededor de 10-11 amperios (su corriente de cortocircuito o Isc). F\u00edsicamente no puede producir m\u00e1s corriente de la que permite el sol.<\/p>\n<p>Por lo tanto, un panel solar <strong>no puede quemarse<\/strong>.<\/p>\n<p>Entonces, \u00bfpor qu\u00e9 fusionamos los arreglos fotovoltaicos? <strong>No estamos protegiendo el panel de s\u00ed mismo. Lo estamos protegiendo de sus vecinos.<\/strong><\/p>\n<p>El peligro es <strong>Corriente de retroalimentaci\u00f3n<\/strong>. Si una cadena falla (por ejemplo, un cortocircuito dentro de un m\u00f3dulo), las <em>otros<\/em> cadenas paralelas volcar\u00e1n su energ\u00eda <em>hacia atr\u00e1s<\/em> en la cadena rota.<\/p>\n<hr \/>\n<h2>Las matem\u00e1ticas: la exenci\u00f3n de \u201c2 cadenas\u201d<\/h2>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-20080\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-Math-The-222-String22-Exemption.webp\" alt=\"The Math- The &quot;2-String&quot; Exemption.webp\" width=\"800\" height=\"800\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-Math-The-222-String22-Exemption.webp 800w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-Math-The-222-String22-Exemption-300x300.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-Math-The-222-String22-Exemption-150x150.webp 150w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-Math-The-222-String22-Exemption-768x768.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-Math-The-222-String22-Exemption-12x12.webp 12w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-Math-The-222-String22-Exemption-600x600.webp 600w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-Math-The-222-String22-Exemption-100x100.webp 100w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<p>Ejecutemos las matem\u00e1ticas que permiten que exista la \u201cParadoja del fusible\u201d.<\/p>\n<p><strong>Las variables:<\/strong><\/p>\n<ul>\n<li><strong>Isc del panel (corriente de cortocircuito):<\/strong> 10 amperios (la potencia de ataque).<\/li>\n<li><strong>Clasificaci\u00f3n m\u00e1xima del fusible en serie:<\/strong> 15 amperios (la potencia de defensa). <em>Esto est\u00e1 impreso en la parte posterior de cada panel solar. Le indica cu\u00e1nta corriente inversa puede soportar el panel antes de que se incendie.<\/em><\/li>\n<\/ul>\n<h3>Escenario A: 2 cadenas en paralelo (el \u201cestancamiento\u201d)<\/h3>\n<p>Tiene la cadena 1 y la cadena 2 conectadas en paralelo.<\/p>\n<ul>\n<li><strong>La falla:<\/strong> La cadena 1 desarrolla un cortocircuito.<\/li>\n<li><strong>El ataque:<\/strong> La cadena 2 fluye hacia atr\u00e1s hacia la cadena 1.<\/li>\n<li><strong>C\u00e1lculo actual:<\/strong> La \u00fanica fuente de corriente es la cadena 2. Entonces, la fuerza de ataque es <strong>10 amperios<\/strong>.<\/li>\n<li><strong>El Resultado:<\/strong> El ataque de 10 A es <strong>menos que<\/strong> el l\u00edmite de 15 A (clasificaci\u00f3n m\u00e1xima del fusible en serie) de la cadena 1.<\/li>\n<\/ul>\n<p>El panel puede soportar el calor. El cable puede soportar el calor. No se produce ning\u00fan incendio.<\/p>\n<p><strong>Veredicto:<\/strong> NEC 690.9 dice <strong>No se requiere fusible.<\/strong><\/p>\n<h3>Escenario B: 3 cadenas en paralelo (la \u201cemboscada\u201d)<\/h3>\n<p>Ahora, agregue una tercera cadena.<\/p>\n<ul>\n<li><strong>La falla:<\/strong> La cadena 1 desarrolla un cortocircuito.<\/li>\n<li><strong>El ataque:<\/strong> Cadena 2 (10A) <strong>Y<\/strong> La cadena 3 (10A) fluye hacia atr\u00e1s hacia la cadena 1.<\/li>\n<li><strong>C\u00e1lculo actual:<\/strong> 10A + 10A = <strong>20 amperios<\/strong>.<\/li>\n<li><strong>El Resultado:<\/strong> El ataque de 20 A es <strong>mayor que<\/strong> el l\u00edmite de 15 A de la cadena 1.<\/li>\n<\/ul>\n<p>La cadena 1 ahora est\u00e1 abrumada. Se sobrecalienta. Se derrite. El techo se incendia.<\/p>\n<p><strong>Veredicto:<\/strong> NEC 690.9 dice <strong>Los fusibles son OBLIGATORIOS<\/strong> en cada cadena.<\/p>\n<hr \/>\n<h2>M\u00e1s all\u00e1 del c\u00f3digo: por qu\u00e9 deber\u00eda fusionar de todos modos<\/h2>\n<p>Entonces, si tiene un sistema de 2 cadenas, el c\u00f3digo dice que puede ahorrar dinero y omitir la fusi\u00f3n de la caja combinadora.<\/p>\n<p>Pero preg\u00fantale a cualquier t\u00e9cnico de servicio veterano y te dir\u00e1n: <strong>\u201cInstale los fusibles de todos modos\u201d.\u201d<\/strong><\/p>\n<p>Aqu\u00ed est\u00e1 el por qu\u00e9 el \u201cM\u00ednimo del C\u00f3digo\u201d no es la \u201cMejor Pr\u00e1ctica\u201d.\u201d<\/p>\n<h3>1. La pesadilla de la \u201cdesconexi\u00f3n en caliente\u201d<\/h3>\n<p>El cumplimiento del c\u00f3digo es excelente hasta que tienes que arreglar algo.<\/p>\n<p>Si omite el portafusibles (que generalmente act\u00faa como un interruptor de desconexi\u00f3n), sus cadenas est\u00e1n conectadas entre s\u00ed (a menudo con conectores en Y).<\/p>\n<p>Si necesita solucionar problemas de la cadena 1, debe desenchufar los conectores MC4. Si el sol brilla, ese circuito est\u00e1 bajo carga. Tirar de un conector MC4 bajo carga crea un <strong>Arco de CC<\/strong>\u2014una llama de plasma que puede derretir los contactos del conector y quemarle las manos.<\/p>\n<p>Un <strong>VIOX PV <a href=\"https:\/\/test.viox.com\/es\/producto\/viox-dc-fuse-holder-vor-32-series\/\">Portafusibles<\/a><\/strong> le brinda una forma segura y a prueba de contacto de \u201capagar\u201d una cadena antes de trabajar en ella. Abre el portador, el circuito se interrumpe dentro de una c\u00e1mara contenida y est\u00e1s seguro.<\/p>\n<h3>2. El factor de \u201cpreparaci\u00f3n para el futuro\u201d<\/h3>\n<p>Los sistemas solares crecen. Puede comenzar con 2 cadenas hoy. Tres a\u00f1os despu\u00e9s, es posible que desee agregar una tercera cadena para cargar un EV.<\/p>\n<p>Si cable\u00f3 su sistema de 2 cadenas sin fusibles (porque \u201cel C\u00f3digo dec\u00eda que no los necesitaba\u201d), agregar esa tercera cadena de repente hace que toda su matriz existente sea ilegal y peligrosa. Tiene que arrancar el cableado y empezar de nuevo.<\/p>\n<p>Si instalaste un <strong>Caja combinadora VIOX<\/strong> con portafusibles desde el primer d\u00eda, agregar una cadena es plug-and-play. Ya est\u00e1s protegido.<\/p>\n<hr \/>\n<div id='gallery-1' class='gallery galleryid-20076 gallery-columns-3 gallery-size-full'><figure class='gallery-item'>\n\t\t\t<div class='gallery-icon landscape'>\n\t\t\t\t<a href='https:\/\/test.viox.com\/es\/?attachment_id=6294'><img decoding=\"async\" width=\"800\" height=\"800\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/RT18-32-Din-Rail-Mounted-10x38-Cartridge-690V-32A-2Pole-4Pole-Fuse-Holder.webp\" class=\"attachment-full size-full\" alt=\"RT18-32 Din Rail Mounted 10x38 Cartridge 690V 32A 2Pole 4Pole Fuse Holder\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/RT18-32-Din-Rail-Mounted-10x38-Cartridge-690V-32A-2Pole-4Pole-Fuse-Holder.webp 800w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/RT18-32-Din-Rail-Mounted-10x38-Cartridge-690V-32A-2Pole-4Pole-Fuse-Holder-300x300.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/RT18-32-Din-Rail-Mounted-10x38-Cartridge-690V-32A-2Pole-4Pole-Fuse-Holder-150x150.webp 150w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/RT18-32-Din-Rail-Mounted-10x38-Cartridge-690V-32A-2Pole-4Pole-Fuse-Holder-768x768.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/RT18-32-Din-Rail-Mounted-10x38-Cartridge-690V-32A-2Pole-4Pole-Fuse-Holder-600x600.webp 600w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/RT18-32-Din-Rail-Mounted-10x38-Cartridge-690V-32A-2Pole-4Pole-Fuse-Holder-100x100.webp 100w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/a>\n\t\t\t<\/div><\/figure><figure class='gallery-item'>\n\t\t\t<div class='gallery-icon landscape'>\n\t\t\t\t<a href='https:\/\/test.viox.com\/es\/?attachment_id=6292'><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"800\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/RT18-63-Din-Rail-Mounted-14x51-Cartridge-690V-32A-2Pole-4Pole-Fuse-Holder.webp\" class=\"attachment-full size-full\" alt=\"VIOX RT18-63 Din Rail Mounted Fuse Holder\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/RT18-63-Din-Rail-Mounted-14x51-Cartridge-690V-32A-2Pole-4Pole-Fuse-Holder.webp 800w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/RT18-63-Din-Rail-Mounted-14x51-Cartridge-690V-32A-2Pole-4Pole-Fuse-Holder-300x300.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/RT18-63-Din-Rail-Mounted-14x51-Cartridge-690V-32A-2Pole-4Pole-Fuse-Holder-150x150.webp 150w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/RT18-63-Din-Rail-Mounted-14x51-Cartridge-690V-32A-2Pole-4Pole-Fuse-Holder-768x768.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/RT18-63-Din-Rail-Mounted-14x51-Cartridge-690V-32A-2Pole-4Pole-Fuse-Holder-600x600.webp 600w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/RT18-63-Din-Rail-Mounted-14x51-Cartridge-690V-32A-2Pole-4Pole-Fuse-Holder-100x100.webp 100w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/a>\n\t\t\t<\/div><\/figure><figure class='gallery-item'>\n\t\t\t<div class='gallery-icon landscape'>\n\t\t\t\t<a href='https:\/\/test.viox.com\/es\/?attachment_id=6288'><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"800\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/RT18-125-Din-Rail-Mounted-22x58-Cartridge-690V-125A-2Pole-4Pole-Fuse-Holder.webp\" class=\"attachment-full size-full\" alt=\"RT18-125 Din Rail Mounted 22x58 Cartridge 690V 125A 2Pole 4Pole Fuse Holder\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/RT18-125-Din-Rail-Mounted-22x58-Cartridge-690V-125A-2Pole-4Pole-Fuse-Holder.webp 800w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/RT18-125-Din-Rail-Mounted-22x58-Cartridge-690V-125A-2Pole-4Pole-Fuse-Holder-300x300.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/RT18-125-Din-Rail-Mounted-22x58-Cartridge-690V-125A-2Pole-4Pole-Fuse-Holder-150x150.webp 150w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/RT18-125-Din-Rail-Mounted-22x58-Cartridge-690V-125A-2Pole-4Pole-Fuse-Holder-768x768.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/RT18-125-Din-Rail-Mounted-22x58-Cartridge-690V-125A-2Pole-4Pole-Fuse-Holder-600x600.webp 600w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/RT18-125-Din-Rail-Mounted-22x58-Cartridge-690V-125A-2Pole-4Pole-Fuse-Holder-100x100.webp 100w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/a>\n\t\t\t<\/div><\/figure>\n\t\t<\/div>\n\n<h2>Resumen: No seas m\u00e1s listo que tu seguridad<\/h2>\n<p>La \u201cParadoja del fusible\u201d es una divertida curiosidad de ingenier\u00eda, pero es una mala filosof\u00eda de dise\u00f1o.<\/p>\n<p>Si bien la f\u00edsica de un sistema de 2 cadenas podr\u00eda salvarlo de un incendio, omitir los fusibles lo priva de control, seguridad y capacidad de expansi\u00f3n.<\/p>\n<ul>\n<li><strong>N \u2264 2 Cadenas:<\/strong> Los fusibles son opcionales (pero recomendados para el aislamiento).<\/li>\n<li><strong>N \u2265 3 Cadenas:<\/strong> Los fusibles son obligatorios (para la protecci\u00f3n contra incendios).<\/li>\n<\/ul>\n<p>No construya solo para la inspecci\u00f3n; construya para los 20 a\u00f1os de funcionamiento que siguen.<\/p>\n<hr \/>\n<h2>La Precisi\u00f3n T\u00e9cnica De La Nota<\/h2>\n<ul>\n<li><strong>Normas:<\/strong>\n<ul>\n<li><strong>NEC 690.9 (Protecci\u00f3n contra sobrecorriente):<\/strong> Define los requisitos para proteger los circuitos de origen fotovoltaico.<\/li>\n<li><strong>Excepci\u00f3n:<\/strong> No se requieren fusibles si las corrientes de cortocircuito de todas las <em>otros<\/em> fuentes no exceden la capacidad de conducci\u00f3n de los conductores o la clasificaci\u00f3n m\u00e1xima de fusibles en serie del m\u00f3dulo.<\/li>\n<\/ul>\n<\/li>\n<li><strong>F\u00f3rmula:<\/strong> La regla general para requerir fusibles es: <code>(N - 1) x Isc &gt; Clasificaci\u00f3n m\u00e1xima de fusibles en serie<\/code>.\n<ul>\n<li>D\u00f3nde <em>N<\/em> es el n\u00famero de cadenas paralelas.<\/li>\n<li><em>Isc<\/em> es la corriente de cortocircuito del panel (ajustada por factores de seguridad de temperatura\/irradiancia, generalmente 1,25).<\/li>\n<\/ul>\n<\/li>\n<li><strong>Soluciones VIOX:<\/strong> VIOX fabrica fusibles gPV de 10x38 mm dise\u00f1ados espec\u00edficamente para interrumpir las fallas de baja sobrecorriente comunes en los arreglos solares de CC, que los fusibles de CA est\u00e1ndar pueden no eliminar.<\/li>\n<\/ul>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>If you are designing a solar array, you know the golden rule of electrical engineering: Wires must be protected by fuses or breakers. So, when you dig into the National Electrical Code (NEC) Section 690.9, you might run into a clause that stops you in your tracks. It suggests that if you have two strings [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":20083,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1],"tags":[],"class_list":["post-20076","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"_links":{"self":[{"href":"https:\/\/test.viox.com\/es\/wp-json\/wp\/v2\/posts\/20076","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/test.viox.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/test.viox.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/test.viox.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/test.viox.com\/es\/wp-json\/wp\/v2\/comments?post=20076"}],"version-history":[{"count":3,"href":"https:\/\/test.viox.com\/es\/wp-json\/wp\/v2\/posts\/20076\/revisions"}],"predecessor-version":[{"id":20082,"href":"https:\/\/test.viox.com\/es\/wp-json\/wp\/v2\/posts\/20076\/revisions\/20082"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/test.viox.com\/es\/wp-json\/wp\/v2\/media\/20083"}],"wp:attachment":[{"href":"https:\/\/test.viox.com\/es\/wp-json\/wp\/v2\/media?parent=20076"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/test.viox.com\/es\/wp-json\/wp\/v2\/categories?post=20076"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/test.viox.com\/es\/wp-json\/wp\/v2\/tags?post=20076"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}