{"id":19811,"date":"2025-11-13T12:36:06","date_gmt":"2025-11-13T04:36:06","guid":{"rendered":"https:\/\/viox.com\/?p=19811"},"modified":"2025-11-13T19:04:11","modified_gmt":"2025-11-13T11:04:11","slug":"why-contactor-has-two-voltages-control-vs-load","status":"publish","type":"post","link":"https:\/\/test.viox.com\/es\/why-contactor-has-two-voltages-control-vs-load\/","title":{"rendered":"\u00bfPor qu\u00e9 mi contactor indica 24 V y 600 V? Una gu\u00eda para diferenciar entre control y carga."},"content":{"rendered":"<div class=\"product-intro\">\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-19830\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/the-contactor-contradiction.webp\" alt=\"the contactor contradiction\" width=\"800\" height=\"800\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/the-contactor-contradiction.webp 800w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/the-contactor-contradiction-300x300.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/the-contactor-contradiction-150x150.webp 150w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/the-contactor-contradiction-768x768.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/the-contactor-contradiction-12x12.webp 12w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/the-contactor-contradiction-600x600.webp 600w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/the-contactor-contradiction-100x100.webp 100w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<p>No tiene sentido.<\/p>\n<p>Est\u00e1s sosteniendo un est\u00e1ndar industrial <a href=\"https:\/\/test.viox.com\/es\/ac-contactor\/\">contactor<\/a>, un bloque de pl\u00e1stico gris que es el caballo de batalla de cada panel de control. Pero es una contradicci\u00f3n andante.<\/p>\n<p>En el lateral, junto a los peque\u00f1os terminales etiquetados como \u201cA1\u201d y \u201cA2\u201d, dice claramente <strong>24V AC<\/strong>.<br \/>\nEn la parte frontal, junto a los terminales de alta resistencia etiquetados como \u201cL1\u201d y \u201cT1\u201d, est\u00e1 clasificado para <strong>600V<\/strong>.<\/p>\n<p>\u00bfEs un error tipogr\u00e1fico? \u00bfEs alg\u00fan tipo de peque\u00f1o transformador? \u00bfC\u00f3mo puede un dispositivo ser <em>ambos<\/em> \u00bf24V y 600V al mismo tiempo?<\/p>\n<p>Esta no es solo una pregunta de libro de texto. Es un rompecabezas del mundo real que recientemente desconcert\u00f3 a un usuario en Reddit, y resulta ser el momento \u201c\u00a1Aj\u00e1!\u201d m\u00e1s importante en la automatizaci\u00f3n el\u00e9ctrica.<\/p>\n<p>Acabas de tropezar con el secreto fundamental de la automatizaci\u00f3n. Resolv\u00e1moslo.<\/p>\n<hr \/>\n<h2>El principio de \u201cCerebro contra M\u00fasculo\u201d: C\u00f3mo un contactor <em>realmente<\/em> Funciona<\/h2>\n<p>Aqu\u00ed est\u00e1 la soluci\u00f3n: Un contactor no es un <em>uno<\/em> dispositivo. Es <strong>dos sistemas completamente separados y el\u00e9ctricamente aislados<\/strong> viviendo en la misma casa.<\/p>\n<p>La comunidad en Reddit acert\u00f3 con la analog\u00eda: tienes que separar el \u201cCerebro\u201d del \u201cM\u00fasculo\u201d.\u201d<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-19831\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-22Brain-vs.-Muscle22-Principle-How-a-Contactor-Really-Works.webp\" alt=\"the &quot;Brain&quot; (Control Circuit) of the contactor\" width=\"800\" height=\"800\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-22Brain-vs.-Muscle22-Principle-How-a-Contactor-Really-Works.webp 800w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-22Brain-vs.-Muscle22-Principle-How-a-Contactor-Really-Works-300x300.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-22Brain-vs.-Muscle22-Principle-How-a-Contactor-Really-Works-150x150.webp 150w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-22Brain-vs.-Muscle22-Principle-How-a-Contactor-Really-Works-768x768.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-22Brain-vs.-Muscle22-Principle-How-a-Contactor-Really-Works-12x12.webp 12w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-22Brain-vs.-Muscle22-Principle-How-a-Contactor-Really-Works-600x600.webp 600w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/The-22Brain-vs.-Muscle22-Principle-How-a-Contactor-Really-Works-100x100.webp 100w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<h3>1. El \u201cCerebro\u201d (El Circuito de Control)<\/h3>\n<ul>\n<li><strong>Esta es tu parte de 24V AC.<\/strong><\/li>\n<li><strong>Terminales:<\/strong> A1 y A2.<\/li>\n<li><strong>Qu\u00e9 es:<\/strong> Un simple electroim\u00e1n, llamado <strong>bobina<\/strong>.<\/li>\n<\/ul>\n<p>Piensa en esto como el \u201cgatillo\u201d. Su <em>s\u00f3lo<\/em> trabajo es recibir una se\u00f1al segura de baja energ\u00eda (en este caso, 24V AC). Cuando recibe esa se\u00f1al, la bobina se energiza y se convierte en un im\u00e1n. Eso es todo. No hace ning\u00fan trabajo pesado. Es el \u201cjefe\u201d que se sienta en una oficina y da una orden.<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-19833\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/the-22Muscle22-Load-Circuit-part-of-the-contactor.webp\" alt=\"the &quot;Muscle&quot; (Load Circuit) part of the contactor\" width=\"800\" height=\"800\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/the-22Muscle22-Load-Circuit-part-of-the-contactor.webp 800w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/the-22Muscle22-Load-Circuit-part-of-the-contactor-300x300.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/the-22Muscle22-Load-Circuit-part-of-the-contactor-150x150.webp 150w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/the-22Muscle22-Load-Circuit-part-of-the-contactor-768x768.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/the-22Muscle22-Load-Circuit-part-of-the-contactor-12x12.webp 12w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/the-22Muscle22-Load-Circuit-part-of-the-contactor-600x600.webp 600w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/the-22Muscle22-Load-Circuit-part-of-the-contactor-100x100.webp 100w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<h3>2. El \u201cM\u00fasculo\u201d (El Circuito de Carga)<\/h3>\n<ul>\n<li><strong>Esta es tu parte de 600V.<\/strong><\/li>\n<li><strong>Terminales:<\/strong> L1\/T1, L2\/T2, L3\/T3.<\/li>\n<li><strong>Qu\u00e9 es:<\/strong> Un conjunto de interruptores de alta resistencia con resorte, llamados <strong>contactos<\/strong>.<\/li>\n<\/ul>\n<p>Este es el \u201cm\u00fasculo\u201d que hace el <em>actual<\/em> trabajo. Estos contactos son solo un puente grueso y conductor. Son completamente \u201ctontos\u201d y no tienen poder propio. Cuando el \u201cCerebro\u201d (la bobina de 24V) se energiza, su atracci\u00f3n magn\u00e9tica cierra este interruptor con un satisfactorio <em>golpe seco<\/em>.<\/p>\n<p>Cuando el interruptor est\u00e1 cerrado, permite que la <em>real<\/em> energ\u00eda, como 480V o 600V, fluya a trav\u00e9s de \u00e9l hacia un gran motor o calentador.<\/p>\n<p>Esta separaci\u00f3n fundamental es lo que los ingenieros llaman <strong>La divisi\u00f3n Control\/Carga<\/strong>.<\/p>\n<blockquote><p><strong>PRO-TIP:<\/strong> Esa clasificaci\u00f3n de 600V es un <em>l\u00edmite<\/em>, no un suministro. No significa que el contactor <em>proporciona<\/em> 600V. Significa que el \u201cM\u00fasculo\u201d (los contactos) est\u00e1 construido con suficiente \u201ccarne\u201d y aislamiento para manejar de forma segura <em>hasta<\/em> 600V fluyendo a trav\u00e9s de \u00e9l sin derretirse o hacer arcos el\u00e9ctricos.<\/p><\/blockquote>\n<hr \/>\n<h2>El \u201cTraductor de HVAC\u201d: Por qu\u00e9 tu termostato no se derrite<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-19834\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/the-22HVAC-Translator22-analogy-to-further-clarify-the-ControlLoad-Divide.webp\" alt=\"the &quot;HVAC Translator&quot; analogy to further clarify the Control\/Load Divide\" width=\"800\" height=\"800\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/the-22HVAC-Translator22-analogy-to-further-clarify-the-ControlLoad-Divide.webp 800w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/the-22HVAC-Translator22-analogy-to-further-clarify-the-ControlLoad-Divide-300x300.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/the-22HVAC-Translator22-analogy-to-further-clarify-the-ControlLoad-Divide-150x150.webp 150w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/the-22HVAC-Translator22-analogy-to-further-clarify-the-ControlLoad-Divide-768x768.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/the-22HVAC-Translator22-analogy-to-further-clarify-the-ControlLoad-Divide-12x12.webp 12w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/the-22HVAC-Translator22-analogy-to-further-clarify-the-ControlLoad-Divide-600x600.webp 600w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/the-22HVAC-Translator22-analogy-to-further-clarify-the-ControlLoad-Divide-100x100.webp 100w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<p>Si esta cosa de \u201cCerebro contra M\u00fasculo\u201d todav\u00eda se siente un poco abstracta, te garantizo que tienes este mismo sistema en tu casa. Es el h\u00e9roe de tu sistema de aire acondicionado.<\/p>\n<p>Un experto en HVAC en ese mismo hilo de Reddit lo llam\u00f3 <strong>\u201cEl traductor de HVAC\u201d.\u201d<\/strong><\/p>\n<p>Piensa en el viaje de una se\u00f1al \u201cfr\u00eda\u201d:<\/p>\n<ol>\n<li><strong>T\u00fa (El Usuario):<\/strong> Sientes calor. Toca \u201cFr\u00edo\u201d en tu elegante termostato inteligente.<\/li>\n<li><strong>El Termostato (\u201cCerebro D\u00e9bil\u201d):<\/strong> Tu termostato es una pieza delicada de electr\u00f3nica. Funciona con 24V AC seguros de bajo voltaje. Es un cerebro \u201cd\u00e9bil\u201d.<\/li>\n<li><strong>La Se\u00f1al (24V):<\/strong> El termostato env\u00eda esa peque\u00f1a se\u00f1al de 24V a trav\u00e9s de un cable delgado a tu unidad compresora exterior.<\/li>\n<li><strong>El Contactor (\u201cEl Traductor\u201d):<\/strong> Dentro de esa unidad exterior grande y ruidosa hay un contactor. Su \u201cCerebro\u201d de 24V (la bobina) recibe la se\u00f1al.<\/li>\n<li><em>CLIC.<\/em><\/li>\n<li><strong>El \u201cM\u00fasculo\u201d (240V):<\/strong> La atracci\u00f3n magn\u00e9tica de la bobina cierra de golpe el \u201cM\u00fasculo\u201d (los contactos). Esto completa instant\u00e1neamente un <em>circuito totalmente separado<\/em>, desatando la \u201cbestia\u201d de 240V y 30 amperios de un circuito desde el panel de interruptores de tu casa.<\/li>\n<li><strong>La Carga:<\/strong> Esa energ\u00eda de 240V ruge a la vida, arrancando el compresor y el ventilador masivos.<\/li>\n<\/ol>\n<p>Sin ese contactor actuando como el \u201ctraductor\u201d, tu delicado termostato inteligente de 24V intentar\u00eda conmutar 240V directamente. \u00bfEl resultado? Se vaporizar\u00eda instant\u00e1neamente en una bocanada de humo y pl\u00e1stico derretido.<\/p>\n<p><strong>La divisi\u00f3n Control\/Carga<\/strong> es la capa de abstracci\u00f3n f\u00edsica que permite que nuestro mundo digital seguro (un termostato de 24 V) controle el mundo anal\u00f3gico peligroso y potente (un motor de 240 V).<\/p>\n<hr \/>\n<h2>Entonces... \u00bfEs un contactor solo un rel\u00e9 grande? (S\u00ed, pero no)<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-19835\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/the-difference-between-a-Contactor-and-a-Relay-focusing-on-Arc-Suppression.webp\" alt=\"the difference between a Contactor and a Relay, focusing on Arc Suppression\" width=\"800\" height=\"800\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/the-difference-between-a-Contactor-and-a-Relay-focusing-on-Arc-Suppression.webp 800w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/the-difference-between-a-Contactor-and-a-Relay-focusing-on-Arc-Suppression-300x300.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/the-difference-between-a-Contactor-and-a-Relay-focusing-on-Arc-Suppression-150x150.webp 150w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/the-difference-between-a-Contactor-and-a-Relay-focusing-on-Arc-Suppression-768x768.webp 768w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/the-difference-between-a-Contactor-and-a-Relay-focusing-on-Arc-Suppression-12x12.webp 12w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/the-difference-between-a-Contactor-and-a-Relay-focusing-on-Arc-Suppression-600x600.webp 600w, https:\/\/test.viox.com\/wp-content\/uploads\/2025\/11\/the-difference-between-a-Contactor-and-a-Relay-focusing-on-Arc-Suppression-100x100.webp 100w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<p>Esta es la siguiente pregunta l\u00f3gica.<\/p>\n<p>\u201cVale\u201d, est\u00e1s pensando, \u201clo entiendo. Un \u2018cerebro\u2019 de 24 V controla un \u2018m\u00fasculo\u2019 de 600 V. Pero eso es <em>exactamente<\/em> lo que hace un <a href=\"https:\/\/test.viox.com\/es\/the-5-different-types-of-relays\/\">rel\u00e9<\/a> rel\u00e9. Una se\u00f1al de 5 V de mi Arduino puede controlar un rel\u00e9 de 120 V para una l\u00e1mpara. As\u00ed que un contactor es solo un rel\u00e9 grande\u201d.\u201d<\/p>\n<p>Este es el error m\u00e1s com\u00fan en el campo. Y es incorrecto.<\/p>\n<p>Si bien comparten el mismo <em>principio<\/em> (<strong>La divisi\u00f3n Control\/Carga<\/strong>principio de funcionamiento <em>su<\/em> prop\u00f3sito <em>es dr\u00e1sticamente diferente. Decir que un contactor es un rel\u00e9 grande es como decir que una camioneta pickup es solo un sed\u00e1n grande. Ambos tienen motores y ruedas, pero uno est\u00e1 dise\u00f1ado para<\/em> transportar.<\/p>\n<p>una carga pesada, y el otro no. <em>s\u00edntoma<\/em>, La diferencia de \"tama\u00f1o\" o \"potencia\" es una.<\/p>\n<p>El <strong>consecuencia<\/strong> , no la causa ra\u00edz. La <strong>VERDADERA.<\/strong><\/p>\n<p>diferencia es la <em>Supresi\u00f3n de arco.<\/em> Cuando se apaga una bombilla simple (una carga resistiva), la electricidad se detiene limpiamente. Pero cuando intentas apagar un motor grande (una carga inductiva), el campo magn\u00e9tico en ese motor colapsa y <strong>arco el\u00e9ctrico<\/strong>.<\/p>\n<ul>\n<li>Un <strong>Rel\u00e9<\/strong> lucha.<\/li>\n<li>Un <strong>Contactor<\/strong> contra ti. No quiere detenerse. Intentar\u00e1 mantener la electricidad fluyendo creando un pico de alto voltaje y alta temperatura, un rayo literal llamado <em>arco el\u00e9ctrico.<\/em>. Un rel\u00e9 es un sed\u00e1n. Est\u00e1 dise\u00f1ado para cargas simples y limpias. Si intenta conmutar un motor grande, ese arco se formar\u00e1 entre sus peque\u00f1os contactos, erosion\u00e1ndolos, derriti\u00e9ndolos y sold\u00e1ndolos r\u00e1pidamente. Juego terminado.<\/li>\n<\/ul>\n<blockquote><p><strong>PRO-TIP:<\/strong> Un contactor es una camioneta pickup. Est\u00e1 <em>interruptores<\/em> construido espec\u00edficamente para eliminar ese arco <em>. Est\u00e1 dise\u00f1ado para sobrevivir al infierno violento y ardiente de la conmutaci\u00f3n de un motor.<\/em> Un rel\u00e9 <strong>motor<\/strong>. conmuta <strong>c\u00e1maras de extinci\u00f3n de arco<\/strong>un circuito. Un contactor.<\/p><\/blockquote>\n<p>sobrevive <strong>Categor\u00edas de utilizaci\u00f3n<\/strong> a la conmutaci\u00f3n de un <em>motor.<\/em> Lo hace con materiales de contacto de alta resistencia, una separaci\u00f3n de contacto m\u00e1s amplia y, a menudo,.<\/p>\n<hr \/>\n<h2>c\u00e1maras de extinci\u00f3n de arco<\/h2>\n<p>: ventilaciones especiales y bobinas magn\u00e9ticas dise\u00f1adas para estirar, enfriar y extinguir ese arco en milisegundos. <em>CA<\/em> Esta es la raz\u00f3n por la que tenemos<\/p>\n<p>categor\u00edas de uso <em>nada<\/em> (como AC-3 para motores), que es el lenguaje de la hoja de especificaciones que le indica <strong>qu\u00e9 tipo de incendio<\/strong>.<\/p>\n<ul>\n<li><strong>est\u00e1 dise\u00f1ado para apagar un contactor.<\/strong> \u00bfPor qu\u00e9 24 V CA? \u00bfY por qu\u00e9 veo bobinas de 24 V CC y 120 V? <strong>Esto nos devuelve a la foto original. \u00bfPor qu\u00e9 una<\/strong> bobina.<\/li>\n<li><strong>de 24 V?<\/strong> El voltaje del \"Cerebro\" no tiene.<\/li>\n<li><strong>que ver con la carga del \u201cM\u00fasculo\u201d. Usted elige el voltaje de la bobina en funci\u00f3n del<\/strong> lenguaje de su sistema de control.<\/li>\n<\/ul>\n<p>:.<\/p>\n<hr \/>\n<h2>24 V CA (El \u201cEspecial de HVAC\u201d):\u201c<\/h2>\n<p>Este es el est\u00e1ndar heredado \u201csuficientemente bueno\u201d para HVAC residencial y comercial, al igual que en la discusi\u00f3n de Reddit. \u00bfPor qu\u00e9? Porque es muy barato y resistente. En la d\u00e9cada de 1950, todo lo que necesitaba era un simple.<\/p>\n<p>transformador <strong>reductor<\/strong> en acci\u00f3n.<\/p>\n<p>para obtener 24 V CA de 120 V CA. Sin rectificadores, sin condensadores de suavizado. Simplemente funcionaba.<\/p>\n<p>24 V CC (El \u201cEst\u00e1ndar PLC\u201d):.<\/p>\n<p>Este es el rey de la automatizaci\u00f3n industrial moderna. Cada PLC (Controlador L\u00f3gico Programable), sensor y controlador de robot funciona con 24 V CC. Es el est\u00e1ndar limpio y amigable para lo digital para la l\u00f3gica de alta velocidad. <em>120 V CA \/ 240 V CA (La \"Vieja Escuela\"):<\/em> Tambi\u00e9n ver\u00e1 contactores con bobinas de alto voltaje. Este es un m\u00e9todo m\u00e1s antiguo en el que simplemente usa el voltaje de l\u00ednea disponible para controlar el contactor. Es simple (no se necesita transformador), pero es menos seguro para los t\u00e9cnicos solucionar problemas de un circuito de control de 120 V \"caliente\".<\/p>\n<p>El contactor en esa foto, con su bobina de 24 V CA, estaba casi seguramente destinado a una unidad de HVAC, no a un gabinete PLC de f\u00e1brica moderno.<\/p>\n<p>De \u201cContradicci\u00f3n\u201d a \u201cPiedra Angular\u201d.<\/p>\n<p><strong>Esa \u201ccontradicci\u00f3n\u201d en una caja de pl\u00e1stico gris no es una contradicci\u00f3n en absoluto. Es la piedra angular de todo el control el\u00e9ctrico moderno.<\/strong><\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>It makes no sense. You\u2019re holding a standard industrial contactor, a gray plastic block that\u2019s the workhorse of every control panel. But it&#8217;s a walking contradiction. On the side, next to the small terminals labeled &#8220;A1&#8221; and &#8220;A2,&#8221; it clearly says 24V AC. On the front, next to the heavy-duty terminals labeled &#8220;L1&#8221; and &#8220;T1,&#8221; [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":19836,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1],"tags":[],"class_list":["post-19811","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"_links":{"self":[{"href":"https:\/\/test.viox.com\/es\/wp-json\/wp\/v2\/posts\/19811","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/test.viox.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/test.viox.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/test.viox.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/test.viox.com\/es\/wp-json\/wp\/v2\/comments?post=19811"}],"version-history":[{"count":3,"href":"https:\/\/test.viox.com\/es\/wp-json\/wp\/v2\/posts\/19811\/revisions"}],"predecessor-version":[{"id":19856,"href":"https:\/\/test.viox.com\/es\/wp-json\/wp\/v2\/posts\/19811\/revisions\/19856"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/test.viox.com\/es\/wp-json\/wp\/v2\/media\/19836"}],"wp:attachment":[{"href":"https:\/\/test.viox.com\/es\/wp-json\/wp\/v2\/media?parent=19811"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/test.viox.com\/es\/wp-json\/wp\/v2\/categories?post=19811"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/test.viox.com\/es\/wp-json\/wp\/v2\/tags?post=19811"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}