{"id":5470,"date":"2024-09-12T17:01:32","date_gmt":"2024-09-12T09:01:32","guid":{"rendered":"https:\/\/viox.com\/?post_type=product&#038;p=5470"},"modified":"2024-09-12T17:06:00","modified_gmt":"2024-09-12T09:06:00","slug":"viox-vsp1-c40-2s-pluggable-single-pole-spd","status":"publish","type":"product","link":"https:\/\/test.viox.com\/de\/produkt\/viox-vsp1-c40-2s-pluggable-single-pole-spd\/","title":{"rendered":"VIOX VSP1-C40\/2(S) Steckbarer einpoliger SPD"},"content":{"rendered":"<div class=\"product-intro\">\n<h2>VIOX VSP1-C40\/2(S) Pluggable Single-Pole SPD<\/h2>\n<h2>Overview<\/h2>\n<p>The VIOX VSP1-C40\/2(S) is a high-performance Pluggable Single-Pole Surge Protective Device (SPD) designed for use in sub-distribution boards. This versatile device offers robust protection for L-PE and N-PE modes, making it an ideal solution for various electrical installations.<\/p>\n<h2>Key Features<\/h2>\n<ul>\n<li>Class II, Type 2, Type 1CA device<\/li>\n<li>Location of Use: Sub-Distribution Boards<\/li>\n<li>Mode of Protection: L-PE, N-PE<\/li>\n<li>Surge Ratings: In = 20 kA (8\/20 \u03bcs)<\/li>\n<li>IEC\/EN\/UL Category: Class II \/ Type 2 \/ Type 1CA<\/li>\n<li>Protective Elements: High Energy MOV<\/li>\n<li>Housing: Pluggable Design<\/li>\n<li>Compliance: IEC 61643-11:2011, EN 61643-11:2012<\/li>\n<\/ul>\n<h2>Technical Specifications<\/h2>\n<table border=\"1\" cellpadding=\"5\">\n<tbody>\n<tr>\n<th>IEC Electrical<\/th>\n<th>75<\/th>\n<th>150<\/th>\n<th>275<\/th>\n<th>320<\/th>\n<th>385<\/th>\n<th>440<\/th>\n<\/tr>\n<tr>\n<td>Nominal AC Voltage (50\/60Hz)<\/td>\n<td>60 V<\/td>\n<td>120 V<\/td>\n<td>230 V<\/td>\n<td>230 V<\/td>\n<td>230 V<\/td>\n<td>400 V<\/td>\n<\/tr>\n<tr>\n<td>Maximum Continuous Operating Voltage (AC)<\/td>\n<td>75 V<\/td>\n<td>150 V<\/td>\n<td>275V<\/td>\n<td>320 V<\/td>\n<td>385 V<\/td>\n<td>440 V<\/td>\n<\/tr>\n<tr>\n<td>Nominal Discharge Current (8\/20 \u03bcs)<\/td>\n<td>20 kA<\/td>\n<td>20 kA<\/td>\n<td>20 kA<\/td>\n<td>20 kA<\/td>\n<td>20 kA<\/td>\n<td>20 kA<\/td>\n<\/tr>\n<tr>\n<td>Maximum Discharge Current (8\/20 \u03bcs)<\/td>\n<td>40 kA<\/td>\n<td>40 kA<\/td>\n<td>40 kA<\/td>\n<td>40 kA<\/td>\n<td>40 kA<\/td>\n<td>40 kA<\/td>\n<\/tr>\n<tr>\n<td>Voltage Protection Level<\/td>\n<td>0.4 kV<\/td>\n<td>1 kV<\/td>\n<td>1.5 kV<\/td>\n<td>1.6 kV<\/td>\n<td>1.8 kV<\/td>\n<td>2 kV<\/td>\n<\/tr>\n<tr>\n<td>Impulse Current (10\/350\u03bcs) Iimp (L-N)<\/td>\n<td colspan=\"6\">7kA<\/td>\n<\/tr>\n<tr>\n<td>Response Time<\/td>\n<td colspan=\"6\">&lt; 25 ns<\/td>\n<\/tr>\n<tr>\n<td>Back-Up Fuse (max)<\/td>\n<td colspan=\"6\">125 A gL \/ gG<\/td>\n<\/tr>\n<tr>\n<td>Short-Circuit Current Rating (AC)<\/td>\n<td colspan=\"6\">25 kA \/ 50 kA<\/td>\n<\/tr>\n<tr>\n<td>TOV Withstand 5s<\/td>\n<td>90V<\/td>\n<td>180V<\/td>\n<td>335V<\/td>\n<td>335V<\/td>\n<td>335V<\/td>\n<td>580V<\/td>\n<\/tr>\n<tr>\n<td>TOV 120min<\/td>\n<td>115V<\/td>\n<td>230V<\/td>\n<td>440V<\/td>\n<td>440V<\/td>\n<td>440V<\/td>\n<td>765V<\/td>\n<\/tr>\n<tr>\n<td>mode<\/td>\n<td>Withstand<\/td>\n<td>Withstand<\/td>\n<td>Safe Fail<\/td>\n<td>Safe Fail<\/td>\n<td>Safe Fail<\/td>\n<td>Safe Fail<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Mechanical &amp; Environmental Specifications<\/h2>\n<ul>\n<li>Operating Temperature Range: -40\u00b0F to +158\u00b0F [-40\u00b0C to +70\u00b0C]<\/li>\n<li>Permissible Operating Humidity: 5%&#8230;95%<\/li>\n<li>Atmospheric pressure and altitude: 80k Pa &#8230; 106k Pa \/ -500 m&#8230;.2000 m<\/li>\n<li>Terminal Screw Torque: 39.9 lbf.in [4.5 Nm]<\/li>\n<li>Conductor Cross Section (max): 2 AWG (Solid, Stranded) \/ 4 AWG (Flexible)<\/li>\n<li>35 mm\u00b2 (Solid, Stranded) \/ 25 mm\u00b2(Flexible)<\/li>\n<li>Mounting: 35 mm DIN Rail, EN 60715<\/li>\n<li>Degree of Protection: IP 20 (built-in)<\/li>\n<li>Housing Material: Thermoplastic: Extinguishing Degree UL 94 V-0<\/li>\n<li>Thermal Protection: Yes<\/li>\n<li>Operating State \/ Fault Indication: Green ok \/ Red defect<\/li>\n<\/ul>\n<h2>Additional Features<\/h2>\n<ul>\n<li>Remote Contacts (RC): Optional<\/li>\n<li>RC Switching Capacity: AC: 250V \/ 0.5 A; DC: 250V \/ 0.1 A;125V \/ 0.2 A;75V \/ 0.5 A<\/li>\n<li>RC Conductor Cross Section (max): 16 AWG (Solid) \/ 1.5 mm\u00b2(Solid)<\/li>\n<\/ul>\n<h2>Internal Configuration<\/h2>\n<p><a href=\"https:\/\/test.viox.com\/?attachment_id=5473\" rel=\"attachment wp-att-5473\"><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-5473\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VSP1-C40_2S-Pluggable-Single-Pole-SPD04.webp\" alt=\"\" width=\"330\" height=\"404\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VSP1-C40_2S-Pluggable-Single-Pole-SPD04.webp 330w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VSP1-C40_2S-Pluggable-Single-Pole-SPD04-245x300.webp 245w\" sizes=\"(max-width: 330px) 100vw, 330px\" \/><\/a><\/p>\n<h2>Dimension<\/h2>\n<p><a href=\"https:\/\/test.viox.com\/?attachment_id=5472\" rel=\"attachment wp-att-5472\"><img decoding=\"async\" class=\"alignnone size-full wp-image-5472\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VSP1-C40_2S-Pluggable-Single-Pole-SPD03.webp\" alt=\"\" width=\"708\" height=\"366\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VSP1-C40_2S-Pluggable-Single-Pole-SPD03.webp 708w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VSP1-C40_2S-Pluggable-Single-Pole-SPD03-300x155.webp 300w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VSP1-C40_2S-Pluggable-Single-Pole-SPD03-600x310.webp 600w\" sizes=\"(max-width: 708px) 100vw, 708px\" \/><\/a><\/p>\n<h2>Connection Diagram<\/h2>\n<p><a href=\"https:\/\/test.viox.com\/?attachment_id=5474\" rel=\"attachment wp-att-5474\"><img decoding=\"async\" class=\"alignnone size-full wp-image-5474\" src=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VSP1-C40_2S-Pluggable-Single-Pole-SPD02.webp\" alt=\"\" width=\"400\" height=\"402\" srcset=\"https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VSP1-C40_2S-Pluggable-Single-Pole-SPD02.webp 400w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VSP1-C40_2S-Pluggable-Single-Pole-SPD02-150x150.webp 150w, https:\/\/test.viox.com\/wp-content\/uploads\/2024\/09\/VIOX-VSP1-C40_2S-Pluggable-Single-Pole-SPD02-100x100.webp 100w\" sizes=\"(max-width: 400px) 100vw, 400px\" \/><\/a><\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<div class=\"msg-content MuiBox-root css-0\">\n<div class=\"break-words\">\n<p>VIOX VSP1-C40\/2(S) Pluggable Single-Pole SPD bietet robusten \u00dcberspannungsschutz f\u00fcr Unterverteilungen. Dieses Ger\u00e4t der Klasse II\/Typ 2\/Typ 1CA sch\u00fctzt die Modi L-PE und N-PE mit einem Nennstrom von 20 kA und einem maximalen Ableitstrom von 40 kA. Das Ger\u00e4t ist mit hochenergetischen MOV-Elementen ausgestattet und arbeitet von 60V bis 400V AC mit einer Ansprechzeit von &lt; 25ns. Das steckbare Design erm\u00f6glicht eine einfache Installation auf 35mm DIN-Schienen. Er entspricht IEC 61643-11:2011 und EN 61643-11:2012 und bietet Spannungsschutzstufen von 0,4kV bis 2kV. Mit Schutzart IP20, thermischen Schutzvorrichtungen und optionalen Fernkontakten eignet sich dieses vielseitige SPD f\u00fcr verschiedene elektrische Installationen und kombiniert Zuverl\u00e4ssigkeit und Leistung in einem kompakten, benutzerfreundlichen Paket f\u00fcr einen verbesserten Schutz von Stromsystemen in anspruchsvollen Anwendungen.<\/p>\n<\/div>\n<\/div>","protected":false},"featured_media":5471,"comment_status":"closed","ping_status":"closed","template":"","meta":{"inline_featured_image":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[],"product_cat":[116,127],"product_tag":[],"class_list":{"0":"post-5470","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-low-voltage-protection-devices","7":"product_cat-surge-protector","8":"desktop-align-left","9":"tablet-align-left","10":"mobile-align-left","12":"first","13":"instock","14":"shipping-taxable","15":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/test.viox.com\/de\/wp-json\/wp\/v2\/product\/5470","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/test.viox.com\/de\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/test.viox.com\/de\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/test.viox.com\/de\/wp-json\/wp\/v2\/comments?post=5470"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/test.viox.com\/de\/wp-json\/wp\/v2\/media\/5471"}],"wp:attachment":[{"href":"https:\/\/test.viox.com\/de\/wp-json\/wp\/v2\/media?parent=5470"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/test.viox.com\/de\/wp-json\/wp\/v2\/product_brand?post=5470"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/test.viox.com\/de\/wp-json\/wp\/v2\/product_cat?post=5470"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/test.viox.com\/de\/wp-json\/wp\/v2\/product_tag?post=5470"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}